digsilent powerfactory function
DESCRIPTION
Disileng refTRANSCRIPT
![Page 1: DIgSILENT PowerFactory Function](https://reader034.vdocuments.mx/reader034/viewer/2022042423/55cf9cac550346d033aaa5c9/html5/thumbnails/1.jpg)
PowerFactory: Functions 1
DIgSILENT PowerFactoryFunctions
![Page 2: DIgSILENT PowerFactory Function](https://reader034.vdocuments.mx/reader034/viewer/2022042423/55cf9cac550346d033aaa5c9/html5/thumbnails/2.jpg)
PowerFactory: Functions 2
Load Flow/Transmission
Fast and Accurate Load Flow Algorithm (Full Newton Raphson,
Newton-Raphson Current Iteration)
AC and DC Networks (for HVDC Transmission)
Secondary Power-Frequency Control
Primary Control
Secondary Reactive Power-Voltage Control
Load Profiling
P-V Curves
All Types of Sensitivities (dv/dQ, dphi/dP, Branch Sensitivities etc.)
Modal dv/dQ Analysis
![Page 3: DIgSILENT PowerFactory Function](https://reader034.vdocuments.mx/reader034/viewer/2022042423/55cf9cac550346d033aaa5c9/html5/thumbnails/3.jpg)
PowerFactory: Functions 3
Load Flow/Distribution
Any Type of Network Technology:
Three-Phase,Three-Phase-Four Wire, Two-Phase, Bi-Phase,
Single Wire-Earth Return, DC Networks
Any Type of Network Topology (Meshed and Radial)
Suited for Extremely Large MV Networks (>20000 Bus Bars)
Voltage Profile Diagrams
Stochastic Load Models for Considering Load Diversity in LV
Networks
One- and Two-Dimensional Load Profiles
Feeder Scaling
Open Point Optimization
![Page 4: DIgSILENT PowerFactory Function](https://reader034.vdocuments.mx/reader034/viewer/2022042423/55cf9cac550346d033aaa5c9/html5/thumbnails/4.jpg)
PowerFactory: Functions 4
Active and Reactive Power
Dispatch
Loss Minimization
Fuel Cost Minimization
Branch Flow Limits
Bus Bar Voltage Limits
Active/Reactive Power Limits
Stator Current Limits
Reserve Constraints
![Page 5: DIgSILENT PowerFactory Function](https://reader034.vdocuments.mx/reader034/viewer/2022042423/55cf9cac550346d033aaa5c9/html5/thumbnails/5.jpg)
PowerFactory: Functions 5
Short Circuit
Short Circuits According to IEC 60909, ANSI C37 and Complete
Superposition Method
Full Implementation of IEC 60909/2001
Multiple Faults Analysis
Fault Types:
Three-Phase
Two-Phase
Two-Phase to Ground
Single-Phase to Ground
Inter-Circuit (also Between Different Voltage Levels)
Open Conductor
Sliding Faults along Lines
![Page 6: DIgSILENT PowerFactory Function](https://reader034.vdocuments.mx/reader034/viewer/2022042423/55cf9cac550346d033aaa5c9/html5/thumbnails/6.jpg)
PowerFactory: Functions 6
Stability
Transient and Dynamic
Stability
Highly Accurate Generator
and Load Models
Large Library of Standard
Models
User Defined Modeling
Variable Step Size Algorithm
Easy-to-Use Chart Definition
Interactive Event Definition
Small Signal Analysis (Modal
Analysis)
Simulates
Any Unbalanced Fault Scenario
![Page 7: DIgSILENT PowerFactory Function](https://reader034.vdocuments.mx/reader034/viewer/2022042423/55cf9cac550346d033aaa5c9/html5/thumbnails/7.jpg)
PowerFactory: Functions 7
Electromagnetic Transients
Detailed Network Model
Transformer Saturation
Transformer Capacitances
Distributed Parameter Line
Models (Constant and
Frequency Dependent)
Detailed (Switching) Power
Electronics Device Models
Easy-to-Use Chart Definition
Interactive Event Definition
Variable Step Size Algorithm
![Page 8: DIgSILENT PowerFactory Function](https://reader034.vdocuments.mx/reader034/viewer/2022042423/55cf9cac550346d033aaa5c9/html5/thumbnails/8.jpg)
PowerFactory: Functions 8
Overcurrent ProtectionModeling
CT and VT Models
Fuses
OCT-Relays
Directional Relays
Differential Relays
LV Circuit Breakers
Coordination
Selectivity Diagrams
Simulation
Steady State
Time Domain
![Page 9: DIgSILENT PowerFactory Function](https://reader034.vdocuments.mx/reader034/viewer/2022042423/55cf9cac550346d033aaa5c9/html5/thumbnails/9.jpg)
PowerFactory: Functions 9
Distance ProtectionModeling
CT and VT Models
MHO-Characteristics
Quadrilateral Characteristics
X/R-Blinder
Starting Characteristics
Inter-Tripping Schemes
Coordination
R-X Diagrams
Time-Distance Diagrams
Simulation
Steady State
Time Domain
![Page 10: DIgSILENT PowerFactory Function](https://reader034.vdocuments.mx/reader034/viewer/2022042423/55cf9cac550346d033aaa5c9/html5/thumbnails/10.jpg)
PowerFactory: Functions 10
Harmonics
Balanced and Unbalanced Harmonic Sources
Characteristic, Non-Characteristic and Inter-Harmonics
Frequency- and Time-Domain Charts
Harmonic Loadflow
Frequency Scan
Frequency Dependent Line
Parameters
Distributed Parameter
Line Models
Filter Sizing
![Page 11: DIgSILENT PowerFactory Function](https://reader034.vdocuments.mx/reader034/viewer/2022042423/55cf9cac550346d033aaa5c9/html5/thumbnails/11.jpg)
PowerFactory: Functions 11
Reliability
Weibul-Markov Failure Models
Line/Transformer/Bus Bar Failures
Common Mode Failures
Double Earth Faults
Circuit Breaker Failures
Protection Failures
Analytical State Enumeration
Monte Carlo Simulation
Advanced System Restoration Models including Generator
Dispatch and Load Shedding
![Page 12: DIgSILENT PowerFactory Function](https://reader034.vdocuments.mx/reader034/viewer/2022042423/55cf9cac550346d033aaa5c9/html5/thumbnails/12.jpg)
PowerFactory: Functions 12
DPL (DIgSILENT Programming
Language)
Arithmetic operations, standard functions
Virtual object functions
Logic operations, lLoops: do{��..} while(�)
Alternative: if(�.) then{�.} else{�}
Access to any system parameter
Use of every command
Every command can be used
Definition of result files, creation of plots