2
DESCRIPTION SAF’s DG8 Series thyristor controllers are designed to control the speed of wound field or permanent magnet DC motors for 1/4 HP to 5 HP. The controllers are available as complete, totally enclosed units suitable for custom applications. When supplied as self-contained units, the converters are provided with transparent, high-impact resistant polycarbonate covers, in a totally-enclosed, non- ventilated format OPERATOR'S CONTROLS The following controls are mounted on the poly- carbonate covers: - 2 pole ON/OFF Switch or Circuit Breaker - Start & Stop Pushbuttons - Forward / Reverse Switch - Speed Control Potentiometer STANDARD FEATURES Isolated current feedback Impedance-isolated armature voltage feedback Provision for tachogenerator (50V/1000 RPM) feedback Separately accessible current loop control Auxiliary Inputs Regenerative braking to zero speed when STOP pushbutton activated Dry contact output when “0” speed is reached Undervoltage protection, converter must be restarted after voltage outage ON/OFF switch or circuit breaker (Nema1) Speed Control Potentiometer (Nema1) PROTECTION One fast-acting fuse in each AC leg Very fast current limit circuit MOV surge supressor Undervoltage protection- controller must be manually restarted after power outage PERFORMANCE Speed Range: 30:1 Load regulation (% Max volts: ±0.5% IR Comp set to 0, 0—full load on motor) Line voltage regulation (% Max volts): ± at full load, for a ±10% line voltage change) Acceleration / Deceleration time (0 to full speed): Adjustable: 0.1 - 30 seconds Operating temperature range: 32ºF - 104ºF (0- 40ºC) Max altitude without derating: 2000 m (6600ft.) Derate by 1% for every 100m above 6600 ft. LED INIDCATION Power On Run Relay Forward Speed Reference Reverse Speed Reference Reversse Converter Output Forward Converter Output Inhibit relay Zero Speed relay AUX relay DG8 DC Drive 1-800-3-ASK-SAF SAF DG8 DC Drive Single Phase, Regenerative Control Special Certification upon request.

Upload: others

Post on 14-Jul-2020

5 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: DG8 DC Drive Single Phase, Regenerative Control Spec.pdf · 2016-10-17 · DESCRIPTION SAF’s DG8 Series thyristor controllers are designed to control the speed of wound field or

DESCRIPTIONSAF’s DG8 Series thyristor controllers are designed to control the speed of wound field or permanent magnet DC motors for 1/4 HP to 5 HP. The controllers are available as complete, totally enclosed units suitable for custom applications. When supplied as self-contained units, the converters are provided with transparent, high-impact resistant polycarbonate covers, in a totally-enclosed, non-ventilated format

OPERATOR'S CONTROLSThe following controls are mounted on the poly-carbonate covers:

- 2 pole ON/OFF Switch or Circuit Breaker - Start & Stop Pushbuttons- Forward / Reverse Switch- Speed Control Potentiometer

STANDARD FEATURES• Isolated current feedback• Impedance-isolated armature voltage feedback• Provision for tachogenerator (50V/1000 RPM)

feedback• Separately accessible current loop control

Auxiliary Inputs• Regenerative braking to zero speed when STOP

pushbutton activated• Dry contact output when “0” speed is reached• Undervoltage protection, converter must be

restarted after voltage outage• ON/OFF switch or circuit breaker (Nema1)• Speed Control Potentiometer (Nema1)

PROTECTIONOne fast-acting fuse in each AC legVery fast current limit circuitMOV surge supressorUndervoltage protection- controller must be manually restarted after power outage

PERFORMANCE• Speed Range: 30:1 • Load regulation (%

Max volts: ±0.5% IR Comp set to 0, 0—full load on motor)

• Line voltage regulation (% Max volts): ± at full load, for a ±10% line voltage change)

• Acceleration / Deceleration time (0 to full speed): Adjustable: 0.1 - 30 seconds

• Operating temperature range: 32ºF - 104ºF (0-40ºC)

• Max altitude without derating: 2000 m (6600ft.) Derate by 1% for every 100m above 6600 ft.

LED INIDCATIONPower OnRun RelayForward Speed ReferenceReverse Speed ReferenceReversse Converter OutputForward Converter OutputInhibit relayZero Speed relayAUX relay

DG8 DC Drive

1-800-3-ASK-SAF

SAF DG8 DC Drive

Single Phase, Regenerative Control

Special Certificationupon request.

Page 2: DG8 DC Drive Single Phase, Regenerative Control Spec.pdf · 2016-10-17 · DESCRIPTION SAF’s DG8 Series thyristor controllers are designed to control the speed of wound field or

MODEL NEMA 1 CHASSIS Length Width Depth Length Width Depth )604("61 1-01-8GD "5.61 )871("7 )612("5.8 "5.8 )604( (216) 5" (127) )604("61 2-01-8GD "5.61 )871("7 )612("5.8 "55.8 )604( "5 )612( (127) )604("61 2-51-8GD "5.61 )871("7 )612("5.8 "5.8 )604( (216) 6" (152) )604("61 2-52-8GD "5.61 )871("7 )612("5.8 "5.8 )604( (216) 6" (152)

)604("61 7.2-03-8GD "5.61 )871("7 )612("5.8 "5.8 )604( (216) 6" (152)Weight 6.5 lbs (2.84kg)

DG8 DC Drive

SAF DG8 Spec - 06/10

DG8 Single Phase Regen DC ConverterDIMENSIONS Inches (mm)

Single Phase, Regenerative Control

Output DC Field SupplyHorsepower Model Volts Amps VDC ADC

NEMA 1 1 DG8-10-1 N1 90V 10A 100V 3A 2 DG8-10-2 N1 180V 10A 200V 3A 3 DG8-15-2 N1 180V 15A 200V 3A 5 DG8-25-2 N1 180V 25A 200V 3A 7.5 DG8-30-2.7 N1 240V 30A 240V 3A

CHASSIS 1 DG8-10-1 CH 90V 10A 100V 3A 2 DG8-10-2 CH 180V 10A 200V 3A 3 DG8-15-2 CH 180V 15A 200V 3A 5 DG8-25-2 CH 180V 25A 200V 3A 7.5 DG8-30-2.7 CH 240V 30A 240V 3A