deltaflux bypass flowmeter
DESCRIPTION
Deltaflux Bypass FlowmeterTRANSCRIPT
-
Construction & Specification
Main Orifice Carrier
:
316 stainless steel orifice mounted in polyester coated carbon steel carrier
Bypass Flow Indicator
:
Nickel-plated copper tubing and brass connections Borosilicate glass indicator tube Viton and polyurethane seals
Float Material
:
Stainless on liquid or Anodised aluminium on gas
Operating Pressure
:
20 bar non shock
Operating Temperature
:
-15C to 90C
Connections
:
Flange Wafer style bolted between flanges DIN or BS10 table E or D Groove Style Optional
Accuracy
:
2% FSD
Deltaflux Shunt Orifice Flowmeter
Cach Instrumentation Technical Datasheet
Cach Instrumentation Ltd Oakwood House 332A Horbury Road Lupset Wakefield WF2 8JQ T: +44 (0)1924 378844 F: +44 (0)1924 378855 E: [email protected] W: www.cacheuk.com
Direct reading scale
Liquid and gas flows
Wafer Flange and Groove style connections
Compact construction
Vertical and horizontal mounting
10:1 turndown
Integral bleed and drain nuts
Full bore isolation valves
Optional alarm
Easily installed and operated
Suited to most common applications
Installation flexibility
Pipeline or remote panel mounted
Suitable for many pipe and flow orientations
Reduced measurement points
Assured operation
Maintenance without breaking connection
Modular system upgrades
F e a t u r e s & B e n e f i t s
-
* Pressure loss at operating flows = Pressure loss at MAX flow x (Operating flow / MAX flow) 2
Grooved style main orifice carriers are available, suitable for use with standard clamp style connectors. Alternative materials of construction are available, including all 316 ss and plastic construction. Remote siting of the indicator, up to 10 metres from the main orifice carrier can be accommodated
using flexible nylon tube.
The indicator can be fitted with a high, low or dual infrared alarm Customised flows for specific operating conditions. Additional Sizes and ranges are available on request
Pipesize mm
H20 m3/hr @ 20C
Scale Code
H20 m3/hr @ 20C
Scale Code
Air m3/hr @ 20C - 1.013 bar
Scale Code
38
2 - 20
WA 85
2 - 10
WA 91
20 - 150
AI 85
50
5 - 40
WA 86
4 - 20
WA 92
40 - 300
AI 86
80
10 - 100
WA 87
10 - 50
WA 93
100 - 700
AI 87
100
20 - 200
WA 88
20 - 100
WA 94
200 - 1500
AI 88
150
50 - 400
WA 89
40 - 200
WA 95
500 - 3500
AI 89
200
100 - 1000
WA 90
80 - 400
WA 96
1000 - 7000
AI 90 * Unrecovered pressure
loss at MAX flow 400 mbar 100 mbar 40 mbar
Pipe Size (mm) Flow range Fluid Type
Example 80 10 - 50m3/hr H20
Order Code DF 80 - WA 93
F l o w R a n g e s For standard schedule 40 pipes
O p t i o n s & A c c e s s o r i e s
Cach Instrumentation Ltd Oakwood House 332A Horbury Road Lupset Wakefield WF2 8JQ T: +44 (0)1924 378844 F: +44 (0)1924 378855 E: [email protected] W: www.cacheuk.com
Cach Instrumentation Technical Datasheet
I n s t a l l a t i o n & M o u n t i n g D i m e n s i o n s
O r d e r i n g C o d e s
The achievable accuracy of the Deltaflux
flowmeter is a function of installation. For
best results, minimum straight lengths of
pipe 10 diameter upstream and 5 diameter
downstream are recommended
d
40mm 5 d 10 d