deltaflux bypass flowmeter

2
Construction & Specification Main Orifice Carrier : 316 stainless steel orifice mounted in polyester coated carbon steel carrier Bypass Flow Indicator : Nickel-plated copper tubing and brass connections Borosilicate glass indicator tube Viton and polyurethane seals Float Material : Stainless on liquid or Anodised aluminium on gas Operating Pressure : 20 bar non shock Operating Temperature : -15ºC to 90ºC Connections : Flange – Wafer style bolted between flanges – DIN or BS10 table E or D Groove Style Optional Accuracy : ± 2% FSD Deltaflux Shunt Orifice Flowmeter Caché Instrumentation Technical Datasheet Caché Instrumentation Ltd Oakwood House 332A Horbury Road Lupset Wakefield WF2 8JQ T: +44 (0)1924 378844 F: +44 (0)1924 378855 E: sales@cacheuk.com W: www.cacheuk.com Direct reading scale Liquid and gas flows Wafer Flange and Groove style connections Compact construction Vertical and horizontal mounting 10:1 turndown Integral bleed and drain nuts Full bore isolation valves Optional alarm Easily installed and operated Suited to most common applications Installation flexibility Pipeline or remote panel mounted Suitable for many pipe and flow orientations Reduced measurement points Assured operation Maintenance without breaking connection Modular system upgrades F e a t u r e s & B e n e f i t s

Upload: nieav280

Post on 17-Sep-2015

3 views

Category:

Documents


0 download

DESCRIPTION

Deltaflux Bypass Flowmeter

TRANSCRIPT

  • Construction & Specification

    Main Orifice Carrier

    :

    316 stainless steel orifice mounted in polyester coated carbon steel carrier

    Bypass Flow Indicator

    :

    Nickel-plated copper tubing and brass connections Borosilicate glass indicator tube Viton and polyurethane seals

    Float Material

    :

    Stainless on liquid or Anodised aluminium on gas

    Operating Pressure

    :

    20 bar non shock

    Operating Temperature

    :

    -15C to 90C

    Connections

    :

    Flange Wafer style bolted between flanges DIN or BS10 table E or D Groove Style Optional

    Accuracy

    :

    2% FSD

    Deltaflux Shunt Orifice Flowmeter

    Cach Instrumentation Technical Datasheet

    Cach Instrumentation Ltd Oakwood House 332A Horbury Road Lupset Wakefield WF2 8JQ T: +44 (0)1924 378844 F: +44 (0)1924 378855 E: [email protected] W: www.cacheuk.com

    Direct reading scale

    Liquid and gas flows

    Wafer Flange and Groove style connections

    Compact construction

    Vertical and horizontal mounting

    10:1 turndown

    Integral bleed and drain nuts

    Full bore isolation valves

    Optional alarm

    Easily installed and operated

    Suited to most common applications

    Installation flexibility

    Pipeline or remote panel mounted

    Suitable for many pipe and flow orientations

    Reduced measurement points

    Assured operation

    Maintenance without breaking connection

    Modular system upgrades

    F e a t u r e s & B e n e f i t s

  • * Pressure loss at operating flows = Pressure loss at MAX flow x (Operating flow / MAX flow) 2

    Grooved style main orifice carriers are available, suitable for use with standard clamp style connectors. Alternative materials of construction are available, including all 316 ss and plastic construction. Remote siting of the indicator, up to 10 metres from the main orifice carrier can be accommodated

    using flexible nylon tube.

    The indicator can be fitted with a high, low or dual infrared alarm Customised flows for specific operating conditions. Additional Sizes and ranges are available on request

    Pipesize mm

    H20 m3/hr @ 20C

    Scale Code

    H20 m3/hr @ 20C

    Scale Code

    Air m3/hr @ 20C - 1.013 bar

    Scale Code

    38

    2 - 20

    WA 85

    2 - 10

    WA 91

    20 - 150

    AI 85

    50

    5 - 40

    WA 86

    4 - 20

    WA 92

    40 - 300

    AI 86

    80

    10 - 100

    WA 87

    10 - 50

    WA 93

    100 - 700

    AI 87

    100

    20 - 200

    WA 88

    20 - 100

    WA 94

    200 - 1500

    AI 88

    150

    50 - 400

    WA 89

    40 - 200

    WA 95

    500 - 3500

    AI 89

    200

    100 - 1000

    WA 90

    80 - 400

    WA 96

    1000 - 7000

    AI 90 * Unrecovered pressure

    loss at MAX flow 400 mbar 100 mbar 40 mbar

    Pipe Size (mm) Flow range Fluid Type

    Example 80 10 - 50m3/hr H20

    Order Code DF 80 - WA 93

    F l o w R a n g e s For standard schedule 40 pipes

    O p t i o n s & A c c e s s o r i e s

    Cach Instrumentation Ltd Oakwood House 332A Horbury Road Lupset Wakefield WF2 8JQ T: +44 (0)1924 378844 F: +44 (0)1924 378855 E: [email protected] W: www.cacheuk.com

    Cach Instrumentation Technical Datasheet

    I n s t a l l a t i o n & M o u n t i n g D i m e n s i o n s

    O r d e r i n g C o d e s

    The achievable accuracy of the Deltaflux

    flowmeter is a function of installation. For

    best results, minimum straight lengths of

    pipe 10 diameter upstream and 5 diameter

    downstream are recommended

    d

    40mm 5 d 10 d