datwyler catalog info tech middle east

384
Cabling Solutions ICT NETWORKS Scalable solutions for high performance network infrastructures

Upload: ali-shoaee

Post on 20-May-2015

1.620 views

Category:

Technology


16 download

DESCRIPTION

Datwyler catalog info tech middle east

TRANSCRIPT

  • 1. ICT Networks Scalable solutions for high performance network infrastructuresCabling Solutions

2. Contents About us ICT Networks ICT Product Overviewpage 2 7 10 Product features: Legend of pictographs The most important test procedures and their functions ROHS WEEE REACHpage 14 16 20Connecting technology Cat.6/EA, shielded 108 111 Connecting technology Cat.6, shielded Connecting technologyCat.5e, shielded 114 Connecting technology Cat.6, unshielded 115 119 Connecting technology Cat.3, unshielded Faceplates120 Patch panels 138 Industrial150 Accessories162 Subfloor systems 170CopperCopper Technology Product overview and selection guide for copper data cables 21 22 At a glance guide: Copper data cables, by Category At a glance guide: Copper connecting hardware, by Category 24 Data cables, shielded 26 56 Data cables, unshielded Telephone cables 62 Trunks68 Patch cords 73 Connecting technology Cat.7A, shielded 100 Connecting technology Cat.6A, shielded 102176 177 178 184 188 190 191 200Product overview and selection guide for outdoor cables 213 Outdoor cables 214 Trunks236 Pigtails238 Patch cords 239 Connectors248 Faceplates251 Panels & enclosures 252 Accessories263Fibre OpticsFibre Optic Technology Product overview and selection guide for optical fibres Checklist: Fibre types, applications and maximum link lengths Singlemode fibres Multimode fibres Fibre optic cables - product overview Product overview and selection guide for indoor and universal cables Indoor cables Universal cablesData Cabinets & Racks 266 272 275Cabinets & RacksData cabinets & racks Cold aisle containment Data cabinet & rack accessoriesData centRe 280 298Data CentreDatwyler Data Centre Solution MHD Modular High Density distribution systemWireless 309WirelessWireless solutionsMultimedia 317MultimediaMultimedia solution320 331 337 343Fibre to the Home (FTTH) Safety cable systems Building automation Elevator cable systems Index of article numbers346 352 358 366 370General InformationGeneral Information Copper technology Fibre optic technology Technical terms used in data cable technology Panorama Management Software Solution 3. Datwyler A reliable partner at your sideDelivering excellence every time, everywhere The lifeblood of a modern public or commercial building is the functionality and reliability of the system solutions for communications, building automation, power supply, safety and lifts. This is true of any such construction, irrespective of whether it is an office block, hotel, sports stadium, television studio or a tunnel. Choose a reliable system partner right from the start: choose Datwyler!Hotels, hospitalsGovernment buildings, universitiesShopping centres2Office blocksData centresTunnelsDatwyler 4. Datwyler is a leading provider of total solutions for the electrical and communications infrastructure of public and commercial buildings and of data centres as well as for Fibre to the home (FTTH) networks. Being a solid, reliable company about to celebrate its 100th year of operation, Datwyler leads the way in innovations for applications such as ICT networks, power supply, fire safety, building automation and lifts. Datwyler is a one-stop source of customised solutions for all your specific applications with all the necessary test certificates, authorisations and approvals and with long-term warranties. Event arenasDatwyler has successfully acted not only as a supplier of innovative products and system solutions but also as the lead or main contractor who, working in close cooperation with local partners, covers the whole value chain: from site surveys, conception and system engineering through installation, logistics and turnkey supply to documentation and system maintenance. The Datwyler Cabling Solutions division is part of Datwyler Group, an international multi-niche player with some 5000 employees which generates approximately 1000 million Euro in sales revenue.FTTx projectsDatwyler3 5. Datwyler Worldwide expertise in turnkey creation, multi-site projects and servicesTurnkey installationsergyImputEnomationElectrical and communications infrastructurePlanningCom muafnicy ettenance MainDatwyler does not only supply integrated system solutions, but has positioned itself successfully as a turnkey partner: for all manner of purpose-built constructions including multi-site projects, for data cenres and for FTTx projects. Our successful processing of turnkey projects derives from our high-level skills in developing and manufacturing the required products and solutions, our comprehenvi ce Ad sive applications expertise, our international presence and our globally established partner network. on S atiaOf course, all our processes are ISO 9001:2008 / ISO 14001:2004 certified.l e me n tat i o nOur sustainable solutions provide you with highlevel operational reliability coupled with low operating costs. The proof that Datwyler systems can deliver these benefits has been evident for many years in thousands of installations around the world. In addition, we have a particularly keen eye for consistent, intelligent solutions that simplify planning, sourcing and installation and shorten your construction times.i BuildngOur international presence and our worldwide, actively managed and certificated partner network have also proved invaluable in the multi-site projects of major clients. National and international companies rely on Datwyler on-the-spot site audits. Using the site surveys as a base, our engineering experts work out customised solutions with uniform standards for all the sites concerned. Our total solutions package is rounded off by the implementation and assurance of regular operations. While operations are running, we provide servicing and maintenance work to optimise your infrastructure solution. These MAC (move, add, change) services increase the performance and working life of your equipment. High-quality solutions for all your applications Year on year, Datwyler invests in even better materials and process technologies, production resources and test methods. This is why our system solutions always keep ahead of the current norms and repeatedly set new standards. The important functions which our solutions must deliver in practice demand the highest possible level of safety and reliability. This is why we measure each product against stringent quality standards before it leaves the company. 4DatwylerWe have the solutions for all your applications, whatever they are high-speed communications networks, modern energy distribution, monitoring and control services, fire alarm systems or lift cabling. Or you may want to integrate new systems, interconnect and automate existing systems or simply ensure a reliable power supply. All this is possible with our carefully thought out, pre-assembled and prefabricated subsystems. Just tell us how, when and where Besides quality and product price, the logistics performance capability of suppliers is a decisive factor in the successful handling of construction projects. This is particularly true of major projects. With its years of experience and high logistics competences, Datwyler can handle even time-critical major projects smoothly and to the complete satisfaction of customers. Just-in-time deliveries at the right place are all in a days work for us and our partners. 6. Besides delivering straight to the construction site, we also offer additional logistics services (time slots, prefitted and pre-assembled products etc.). Many customers and suppliers have a direct link to our IT system for rapid and flexible order processing. As regards cable pre-assembly, Datwyler also has wide-ranging expertise, the product of decades of experience. In our modern cable cutting centre, the engineering department passes the cutting orders electronically without any media discontinuity straight to the production area. Our efficient order communication system with all our customers is due to years of experience with B2B interfaces. In many countries Datwyler works in close co-operation with independent distribution partners. Thus, our customers can rely on the consistently high quality standard of all Datwyler products and solutions whilst benefiting from local contacts and logistics services. We support you in realising your infrastructure project reliably, capably, complete and with the highest quality!Datwyler5 7. High-speed communicationICT Networks6Datwyler 8. From analogue telephony up to 10/40/100G; from Local Area Network and high-speed data centre cabling to entire carrier and Fibre to the home networks Datwyler is your preferred partner for top-quality, reliable and future-proof ICT networks in copper and fibre optics. With outstanding products and system solutions, Datwyler set standards for quality, performance and investment protection.Media convergence in communication is an irreversible trend, and the demand for ever increasing bandwidth continues to boom. IP technology is merging telephone, television and Internet. Multimedia a magic word just a few years ago is already reality. Future-proof thanks to high-quality solutions With the technical possibilities to constantly increase transfer rates, requirements for cable systems are becoming more demanding. The high-quality solutions of Datwyler exploit the full potential of networks and offer high investment security for the future. The comprehensive product range extends from single cables and components to complete end-to-end systems. Modular solutions for every application Datwyler modular solutions are suitable for all sizes and types of networks from residential cabling to cabling systems for offices or industrial buildings to campus, access, or carrier networks for thousands of users. Telecom providers rely on our experience and know-how, as do banks, insurance companies, universities, hospitals, airports, car manufacturers and industrial companies.Datwyler7 9. System solutions from a single sourceICT NetworksLeading know-how As a provider of total solutions for information and telecommunication networks, Datwyler possesses extensive know-how accumulated over decades: - Almost 100 years of experience in cable production. - Leading material, production and process know-how in the fabrication of copper and fibre-optic cables and components. - Solid electro-technical competency. - Close collaboration with renowned technical universities, international standards committees, and independent testing institutes. - Broad systems competence. Diverse applications In the field of ICT networks Datwyler concentrates on communication infrastructures for public and commercial buildings and for FTTx networks. Some examples are: - - - - - -Office, industrial and exhibition buildings Data centres Hotels and hospitals Stadiums, theatres, concert halls Airports and train stations FTTx projects of public utility companies and energy supply companiesIn these market segments we can also flexibly meet individual customer requirements up to and including turnkey and multi-site projects with our cost-effective, modular system solutions and compehensive services.8Datwyler 10. Complete system solutions - Screened and unscreened copper system solutions (categories 3 to 7A) for the transmission of voice, data, video, CATV, control signals and remote power (power over Ethernet, PoE+). - Innovative fibre-optic system solutions with singlemode and multimode optical fibres for indoor and outdoor applications, from LAN backbones to FTTH in-house cabling. - Software solution for building, technology and network management. - Extensive services ranging from consulting and planning via pre-fabrication, logistics and installation to system maintenance. - Established worldwide, actively managed and certificated partner network. - Rigorous training and certification programme to guarantee optimal installation quality of our systems and solutions. - Long-term warranty covering the entire system.Yangshan Deepwater Port administration centre, ShanghaiSelected reference projects Airrail Center Party school campus Kunming Airport UBI Banca (1964 branch offices) Swiss parliament building Dexia BILFrankfurt a.M. Rathbones Hangzhou Dubai Motor City Kunming Swisscom IT Services Bergamo UBS central administration, Flurhof Berne Allianz Arena Luxembourg KPMG German headquartersLondon Dubai Zollikofen Zurich Munich BerlinFocus on customer value Datwyler stands for more than just the fabrication and distribution of products. For your ICT networks we offer future-proof, modular, customised one-source solutions for all your specific applications as a uniquely attractive overall package, with all the necessary test certificates, authorizations and certificates and with long-term warranties. The interaction of these elements creates added value. As a customer you benefit from maximum network availability and high investment protection, even with regard to future applications, expansions and changes.Allianz Arena, MunichDatwyler9 11. Product OverviewIntegrated, future-proof cabling solutions for ultimate reliability in voice, data, video and CATV applicationsCopper patch cords PS-TERATM/RJ45More than just products With the complete packages offered by Datwyler you are opting for comprehensive application-neutral and providerindependent system solutions encompassing the communication infrastructure for office and industry environments and for FTTx. For Datwyler, quality testing and quality management begin during the cable production process. Here relevant electrical and mechanical data are recorded online and automatically compared with the predefined specifications. The performance values of our cables generally exceed current standards and drafts by considerable margin. Datwyler follows the same procedure for the production of connection components, e.g. data outlets, patch panels and patch cables for copper and fibre optic systems.Module PS-TERATM Faceplate for PS-TERATM module 1/8 Cat.7AFaceplate for MS-K Plus 1/8 modulesRJ45 module MS-K Plus 1/8 Cat.6AIndustrial data outlet IP67 for MS 1/8 moduleMarking of individual components ensures that data measured up to the time of production can be called up at any point in the future. This gives users or investors a high degree of certainty that the products used and manufactured provide the durability demanded by them.Copper patch panels MPS 12x, 16x, 24x, 32x for MS 1/8 or PS-TERATM modulesIndustrial REG adapter MS IP20 for MS 1/8 moduleIndustrial patch cord PURCopper patch cordsData outlet CSA Plus 2/8 Cat.6A (IEC)Copper patch panel CSA 24/8 Plus Cat. 6A10Datwyler 12. FO patch panel OV-A FO data outletsFO patch cordsFO wall-mounted distribution box OV-WFO Indoor cablesFO Universal cables FO Safety cablesCopper data cables (solid) / copper flexible cablese.g.: Cat.6A: 7060 4P Cat.7: 7080 4P better than Cat.7A: 7150 4PMultimedia CAT TV Balun, active balun up to 862 MHz for the distribution of CATV signalsMultimedia CAT TV Panel, active distribution panel up to 862 MHz for the distribution of CATV signals in LANsDatwyler11 13. Product OverviewCopperFibre opticSCablesConnectionCablesConnectionCopper installation / flexible cableCopper modulesFibre optic indoor cableFibre optic adapters and couplersCopper patch cordsCopper patch panelsFibre optic universal and safety cableFibre optic patch panelsCopper multiple cables (trunks), highly flexible, pre-assembledCopper faceplatesFibre optic patch and adapter cableFibre optic faceplatesCopper multiple cable (trunk), highly flexible, pre-assembledFloor-box solutionsFibre optic multiple cable (trunk)Fibre optic wall mounted distribution boxesMeasurement cablesAccessoriesFibre optic multiple cable (trunk) BreakOutFibre optic accessoriesshielded / unshieldedshielded / unshieldedAre you looking for a building, technology and network management software which enables effective planning, management, documentation and control of all objects and processes around your infrastructure? Feel free to ask for details about Panorama!12Datwyler 14. Rack SystemsData centre solutionSWireless SolutionsmultimediANetwork-/Server racksFO-DCS and MHDWiFiMultimedia and switchingNetwork rackFO-DCS modular subrackWiFi ArraysCAT TV Panel active distribution panel up to 862 MHz for the distribution of CATV signalsServer rackFO-DCS MTP-LCD plug-in modulesTransformersCAT TV Balun active balun up to 862 MHz for the distribution of CATV signalsWall mounted boxMHD multiple cables (trunks) pre-assembled copper data cablesAccess pointsNetwork cameraMHD FO distribution cartridgesManagement systemVideo monitoring systemMHD multiple cables pre-assembled FO data cablesWiFi accessoriesSwitchesMinirackIT rack accessoriesModular High-Speed and High Density cabling systemsPowerful Wireless FidelityDatwyler13 15. Product featuresThe following pictograms show the essential features of our products and give an easy reference. They are allocated to the articles on the data sheets and provide you with a quick overviewZero halogen, non corrosive gasesCables use a high performance, flame retardant material that is self extinguishing.IEC 60332-1-2, EN 60332-1-2, VDE 0482-332-1-2Flame spreadCables are flame resistant and prevent the propagation of a fire from one location to anotherIEC 60332-3-22 to 25 cat. A-D, EN 60332-3-22 bis 25 cat. A-D, VDE 0482-332-3-22 to 25 cat. A-DSmoke densityCables emit minimum smoke in the event of fire. Exit routes and fire brigade access are not restricted.IEC 61034-1 and IEC 61034-2, EN 61034-1 and EN 61034-2, VDE 0482-1034 part 1 and 2Circuit integrity [FE/PH]Cables with circuit integrity guarantee the function of a single cable for a defined duration. (FE is for flame time and influence time)IEC 60331-1, IEC 60331-2 and part 21,23, 25, EN 50200 with Annex E, EN 50362, VDE 0472 part 814, VDE 0482-200, VDE 0482-362, BS 8434-2, BS 6387 (cat. C/W/Z)System Circuit integrity [E30-E90]DatwylerIEC 60754-1 and IEC 60754-2, EN 50267-2-1, EN 50267-2-2, EN 50267-2-3 VDE 0482-267 part 2-1, 2-2 and 2-3Flame propagation14Cables are halogen-free and reduce possible damage to health or material to a minimum.Cables (together with certified fixing systems) guarantee enhanced circuit integrity of the complete electrical cable installation for a defined time. (E30=30 minutes, E60=60 minutes, E90=90 minutes)DIN 4102 part 12 [E30-E90] NBN 713.020 (Rf1, Rf1) 16. MmodularModular design of the connection technique with changeable modules. Providing the possibility of faster maintenance and hassle-free alterations in the event of increased user demand.EMV shieldedFully shielded faceplates/outlets, patch panels and data cables, ensuring the compliance with the EMC guidelines according to EN55022 and indisrupted operation. The compatibility with other systems in the environment is guaranteed due to the excellent shielding of all cables and components.Power over Ethernet PoE+ (IEEE 802.3at)30 Wfor copper data cables with AWG 22Power over Ethernet PoE+ (IEEE 802.3at)30 Wfor copper data cables < AWG 22Power over Ethernet PoE (IEEE 802.3af)15 Wfor copper data cablesROHSDirective 2011/65/EUof the European Parliament and of the Council of 08. June 2011 on the restriction of the use of certain hazardous substances in electrical and electronic equipment. (revised form)Datwyler15 17. The most important test procedures and their functionsTest on gases evolved during combustion This test procedure provides information if the insulation material of the cable sheath creates corrosive gases in the event of fire. Halogen parts or other material in small quantities can be easily identified with this test due to the strong change of pH and conductivity. The conductivity is < 10mS/mmStandards - IEC 60754-1 and IEC 60754-2 - EN 50267-2-1, EN 50267-2-2 - EN 50267-2-3 - VDE 0482-267 part 2-1, 2-2 and 2-3Test for vertical flame propagation (single insulated wire or cable) This test method tests a cable sample (length: 60 cm) for burning behaviour. The flame must extinguish itself, and the burn damage must not reach the upper end of the cable sample.Standards - IEC 60332-1-2 - EN 60332-1-2 - VDE 0482-332-1-2Test for vertical flame spread (bunched wires or cables) This test method tests a cable bundle (length: 360 cm) with regard to fire propagation. The flames must extinguish themselves, and burn damage must not exceed a defined height. Standards -IEC 60332-3-22 up to 25 Cat A-D -EN 60332-3-22 up to 25 Cat. A-D -VDE 0482-332-3-22 up to 25 Cat. A-DMeasurement of smoke density This test checks smoke development when burning the cable or the impairment of the visibility by burning cables. The reduction in light transparency is measured in a standard chamber.16DatwylerStandards -IEC 61034-1 and IEC 61034-2 -EN 61034-1 and EN 61034-2 -VDE 0482-1034 part 1 and 2 18. The most important test procedures and their functionsTest of circuit integrity (FE/PH) This test establishes whether a single cable can maintain circuit integrity during and after exposure to a fire for a time period of at least 180 minutes. Cables which fulfil the requirements of this test are marked with FE180 after their type designation. There is no obligation to test the cable for functional integrity beyond the designated period. Remark: This test is not equivalent to the test for functional integrity in accordance with DIN 4102-12 Test of circuit integrity (fire alone) -IEC 60331-11/-21/-23/-25 [>750C] -BS 6387 (cat. C) [950C] -VDE 0472-814 [>750C]Test of circuit integrity (fire and water) - BS 6387 (cat.W) [650C, 3A] - VdS 3423 [>830C, 3A] - EN 50200 Annex E [>830C, 2A]Test of circuit integrity (fire and mechanical shock) -IEC 60331-1/-2 [>830C, 2A] -EN 50200 (PH) [>830C, 2A] -EN 50362 [> 830C, 2A] -BS 6387 (cat.Z) [950C, 3A]Test of system circuit integrity of electrical cable installations This standard describes the requirements and the actions to achieve the enhanced functional integrity of complete electrical cable installations in the event of fire. While the circuit integrity (FE/PH) provides only for the test of single cables, the cables here are tested in connection with practical support and fixing systems. It is important to appreciate that there is no connection between the two standards - circuit integrity (FE/ PH) and system circuit integrity (E). The test is carried out and certified from state recognised institutes. Standards- DIN 4102 part 12 (E30-E90) - NBN 713-020 (Rf1, Rf11/2)Better than the standard! This test (E30-E90) is the only worldwide standard for guaranteeing functional integrity of the complete electrical cable installation, including the support and fixing components, under normal operating conditions.Datwyler17 19. The most important test procedures and their functionsTemperature change and humidity This test procedure checks the electrical parameters (LF and HF) of a data cable following temperature or humidity changes. Test conditions for the temperature and humidity dependent measurements must simulate the worst conditions. Standard - IEC 60794-1-2F1Tensile performance This test checks the behaviour of the electrical LF and HF parameters as a function of the pulling force of the data cable, such as that occurring during draw-in. This is not a destructive test. This means that the cable is loaded with the maximum allowable pulling force. Standard - IEC 60794-1-2-E1BRepeated bending The behaviour of a data cable is determined by bending a cable sample forwards and backwards 180 degrees several times. Afterwards, the cable must still fulfil the electrical LF and HF parameters according to the EN 50173 standard. Standard - IEC 60794-1-2-E6Hammer blow In order to determine the resistance of a data cable against impacts, a wedge is allowed to fall vertically onto the cable. Afterwards, the cable must still fulfil the electrical LF and HF parameters according to the EN 50173 standard.18Datwyler 20. The most important test procedures and their functionsImpact The fall of a heavy tool, device, stone, etc. onto the cable is simulated here. The weight is allowed to fall vertically onto an intermediate steel piece that transmits the force to the cable sample. No damage to the cable sheath may occur. Standard - IEC 60794-1-2-E4Crush resistance The purpose of this test is to determine the ability of a data cable to withstand transverse pressure. After that, the electrical LF and HF parameters must still correspond to the EN 50173 standard. Standard - IEC 60794-1-2-E3Torsion During installation, a fibre optic cable must withstand torsion forces in addition to tension, transverse pressure and bending loads. Thus, a cable sample is turned about its own axis. Attenuation deviations are documented during the test. Neither fibre nor sheath materials may be damaged during the test. Standard - IEC 60794-1-2-E7Water penetrationmethod Amethod BThis method checks whether all interstices of a fibre optic outdoor cable are continuously filled with a compound that prevents water from entering the cable. Determining test criteria are the time and the maximum dispersal of the water within the sample. Datwyler uses the more difficult test method B exclusively. Standard - IEC 60794-1-2-F5-A/BDatwyler19 21. ROHS WEEE REACHStatement from Datwyler: As an environmentally conscious manufacturer and supplier of cabling solutions it is our concern not to use any environmentally harmful substances in our products. Based on current information, the hereinmentioned guidelines / regulations for banned substances are fully complied with. Exceptions are noted as such on the relevant data sheet.ROHSREACHDIRECTIVE 2002/95/EC OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL of 08. June 2011 on the restriction of the use of certain hazardous substances in electrical and electronic equipmentREGULATION (EC) No 1907/2006 OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL of 18 December 2006 concerning the Registration, Evaluation, Authorisation and Restriction of Chemicals (REACH), establishing a European Chemicals Agency, amending Directive 1999/45/EC and repealing Council Regulation (EEC) No 793/93 and Commission Regulation (EC) No 1488/94 as well as Council Directive 76/769/EEC Commission Directives 91/155/EEC, 93/67/EEC, 93/105/EC and 200/21/ECWEEE DIRECTIVE 2002/96/EC OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL of 4 July 2012 on waste electrical and electronic equipment (revised form)20Datwylerand COMMISSION REGULATION (EU) No 143/2011 of 17 February 2011 amending Annex XIV to Regulation (EC) No 1907/2006 of the European Parliament and of the Council on the Registration, Evaluation, Authorisation and Restriction of Chemicals 22. CopperCU 7150 4P Multimedia / 2x4P F8 MultimediaSuitable for industrial applicationsSuitable for outdoor useStabilising element (cross)Multimedia according to EN 50083-8Halogen free cable sheath (FRNC/LS0H)PVC cable sheath (FR/PVC)Bundle cablePimF (Pair in metal Foil)Suitable for patch and connecting cablesSuitable for backbone and vertical/riser cablingSuitable for horizontal cablingCable Sharing10 Gigabit-EthernetGigabit-Ethernet 1000 BaseTEthernet 10 BaseT/100 BaseTCoppershielded 26Telephone, ISDNCategory/Classpage Cable typeCable designThe following overview lists some of the more important criteria which will help you to decide for the cable types that meet your specific requirements.AWG = American Wire GaugeThe Datwyler product portfolio consists of many different cable types.Video signals (RGB): symmetrical transmissionSelection criteriaStabilizing element (intermediate sheath for mech. stabilization)Product overview and selection guide for copper data cablesS/FTP 22 7A/FA (1000 MHz)28CU 7702 4P / 2x4P F8S/FTP 22 7A/FA (1000 MHz)30CU 7120 4P / 2x4P F8S/FTP 23 7A/FA (1000 MHz)32CU 7080 4P / 2x4P F8S/FTP 23 7/F (600 MHz)34CU 7002 4P / 2x4P F8S/FTP 23 7/F (600 MHz)CU 7002 nx4P Breakout Light (BOL)S/FTP 23 7/F (600 MHz)CU 7002 4P Industrial PURS/FTP 23 7/F (600 MHz)40CU 7002 4P GG-PES/FTP 23 7/F (600 MHz)42CU 7052 4P / 2x4P F8F/FTP 23 7/F (600 MHz)44CU 7060 4P / 2x4P F8S/FTP 23 6A/EA (500 MHz)46CU 6552 4PF/FTP 23 6A/EA (500 MHz)48CU 6502 4PFibre Optics36 38U/FTP 23 6A/EA (500 MHz)50CU 6052 4P / 2x4P F8F/FTP 23 6/E (250 MHz)52CU 6702 4PSF/UTP 24 6/E (250 MHz)58CU 5002 4PF/UTP 24 5e/D (100 MHz)60CU 7150 4P flexS/FTP 26 7A/FA (1000 MHz)62CU 7702 4P flexS/FTP 26 7/F (600 MHz)64CU 7702 4P flex Industrial PURS/FTP 26 7/F (600 MHz)66CU 1P flex MultimediaS/FTP 26 7/F (600 MHz)68CU 2P flex MultimediaS/FTP 26 7/F (600 MHz)70CU 5502 4P flexS/UTP 26 5e/D (100 MHz)unshielded CU 662 4PU/UTP 24 6/E (250 MHz)74CU 502 4PU/UTP 24 5e/D (100 MHz)76CU 602 4P flexU/UTP 24 6/E (250 MHz)Multimedia72Cabinets & RacksU/FTP 23 6/E (250 MHz) SF/UTP 24 5e/D (100 MHz)Data CentreCU 6002 4P CU 5502 4PWireless54 56DATWYLER 25-pair IndoorU/UTP 24 3/C (16 MHz)80DATWYLER 50-pair IndoorU/UTP 24 3/C (16 MHz)82DATWYLER 100-pair IndoorU/UTP 24 3/C (16 MHz)Subject to technical modification.General InformationTelephone cable 7821 23. CopperAt a glance guide: Copper data cables, by CategoryCategory/Class7A/FA (1000 MHz)Data cable shieldedCU 7150 4P Multimedia / 2x4P F8 Multimedia40GBase-T (in the future) CU 7702 4P / 2x4P F8CopperCU 7120 4P / 2x4P F87/F(600 MHz)CU 7002 4P Industrial PURCU 7002 4P / 2x4P F8CU 7002 4P GG-PECabinets & Racks Optics FibreFibre OpticsCU 7080 4P / 2x4P F8CU 7052 4P / 2x4P F8 CU 7002 nx4P Breakout Light (BOL)6A/EA(500 MHz)CU 7060 4P / 2x4P F810GBase-TGeneral Information General InformationMultimedia MultimediaWirelessData Centre WirelessCabinets & Racks Centre DataCU 6552 4P22CU 6502 4P6/E (250 MHz)CU 6052 4P / 2x4P F8CU 6702 4PCU 6002 4P5e/D(100 MHz)CU 5502 4P1000Base-T / 100Base-T CU 5002 4PSubject to technical modification. 24. CopperCables with higher category fulfil all requirements of the categories below.Flexible cable shieldedData cable unshieldedFlexible cable unshieldedCopperCU 7150 4P flexCU 7702 4P flexCU 7702 4P flex Industrial PURCU 1P flex MultimediaCU 602 4P flexCU 5502 4P flexSubject to technical modification.CU 502 4PGeneral InformationMultimediaWirelessCU 662 4PData CentreCabinets & RacksFibre OpticsCU 2P flex Multimedia23 25. CopperAt a glance guide: Copper connecting hardware, by CategoryCategory/ClassCopper connecting hardware shielded7A/FA (1000 MHz) 40GBase-T (in the future)7/F(600 MHz)Multimedia MultimediaWireless General Information General InformationModule PS-TERA 4P Cat.7AAll Cat.7 components have been optimized for the Cat./A requirements.6A/EA(500 MHz) 10GBase-T* Module KS-T Plus 1/8 Module MS-K Plus 1/8 toolless Cat.6A (IEC) Cat.6AModule MS-C6A 1/8 Cat.6A (IEC) 180 - K (Keystone)6/EA (500 MHz) Module KS-T 1/8 toolless Cat.6/EAModule KS-TS 1/8 toolless slimline Cat.6/EAModule MS 1/8 Cat.6/EA6/E (250 MHz) Patch panel CSP 24/8 Cat.65e/D(100 MHz) 1000Base-T / 100Base-T Module KS-T 5 1/8 toolless Cat.5e Please find an up-to-date matrix showing which patch panels and outlets are suitable for the insertion of the respective Datwyler module on our homepage www.datwyler.com.24Module MS-C6A 1/8 Cat.6A (IEC) 180*) In case of using these modules for 10GBase-T (Class EA) applications we recommend Cat.7 or Cat.7A data cablesData Centre WirelessCabinets & Racks Centre DataCabinets & Racks Optics FibreFibre OpticsCopperModule PS-GG45 7ASubject to technical modification.RJ45 Keystone coupler (RJ45-RJ45), 180, straightRJ45 Feed-trough coupler MS/KS, angled 26. CopperModules with a higher category implements all requirements of the category below.CopperCopper connecting hardware unshieldedUP/K Faceplate CSA Plus 1/8 Cat.6AFibre OpticsUP/K Faceplate CSA Plus 2/8 Cat.6ACabinets & RacksPatch panel CSA Plus 24/8 Cat.6A (IEC)Module KU-T 1/8 toolless Cat.6Module KU-T 1/8 toolless Cat.5eSubject to technical modification.Module MU 1/8 Patch panel CU 24/8 Cat.6 Cat.6Patch panel CUP 24/8 Cat.6General InformationRJ45 Feed-trough coupler MS/KS, straightMultimediaWirelessData CentrePlease note: These modules also fulfil all Class EA Channel requirements when connected to Cat.7 oder Cat.7A data cables.25 27. Copper data cables, shieldedData cable S/FTP Cat.7A AWG22 CU 7150 4P Multimedia / 2x4P F8Screen Tinned braided copperWire 1.6 mm Screen pair Alu PETP foilOuter sheath FRNC/LS0H orange RAL 2003Inner conductor AWG22 Bare copper wireCopperProduct information Electrically and mechanically high-quality Cat.7A data cable - exceeds the requirements of ISO/IEC 11801, IEC 61156-5, IEC 61156-7, EN 50173-1 and prEN 50288-9-1. Excellent shielding effect due to individually screened pairs and overall copper braid. Easy identification of wires thanks to longitudinal colour markings. Compatible with all current connecting hardware in accordance with EN 50173 and ISO/IEC 11801.ApplicationsData cable for structured premises cabling. For the transmission of digital and analogue voice, video and data signals. Suitable for all ICT network applications up to class FA applications (1000 MHz) in accordance with EN 50173-1 and ISO/IEC 11801. Optimized for the transmission of broadband signals (such as cable TV) in accordance with IEC 15018. Due to the increased wire section eminently suited for Power over Ethernet (PoE) / PoE+.Cabinets & RacksFibre OpticsFeaturesVersions DimensionSheathSheath Weight n x n x mm (AWG) mm kg/km1829254 x 2 x 0.64 (AWG22)FRNC/LS0H1)182926Data CentreArticle No. 2 x (4 x 2 x 0.64 (AWG22))FRNC/LS0H1)FRNC/LS0H = Flame Retardant Non Corrosive / Low Smoke Zero Halogen26CU 7150 4P 0312/eGeneral InformationMultimediaWireless1)Subject to technical modification.7.8 7.8 x 16.4Cu weightFire loadPU kg/km kWh/m MJ/m69.240.20.180.65139.280.40.361.301000 m drum 500 m drum 28. Copper data cables, shieldedData cable S/FTP Cat.7A AWG22CU 7150 4P Multimedia / 2x4P F8Electrical Characteristics 5e66A7CATV7A101002505006008621000Category Frequency [MHz]1Attenuation [dB/100 m]461156-7 120015001.73.24.916.226384049545868NEXT [dB]103103103103103989692908580PS NEXT [dB]100100100100100959389878277ACR-N [dB]101100988777605643362712989795847457534033249PS-ACR-N [dB] ACR-F [dB]1101081069484716658554641PS-ACR-F [dB]10710510391816863555243382630333328262524232320 Copper[dB] 1401 NEXT 7150120 1002 NEXT IEC 61156-5 Cat.7A13 Attenuation IEC 61156-5 Cat.7A260430 1 [MHz]General Characteristics1'000 4P CU 7150 Bending radius (flat side) during draw-in: 64 mm permanently installed: 32 mm Tensile strength: 130 N Crush resistance: 1000 N/10 cm Impact resistance: 10 impacts Temperature range during installation: 0 C to + 50 C in operation: -20 C to + 60 C10'000CU 7150 2x4P F8 64 mm 32 mm 260 N 1000 N/10 cm 10 impacts 0 C to + 50 C -20 C to + 60 CWire colour code white-blue/blue white-orange/orange white-green/green white-brown/brown (with longitudinal stripes) in accordance with IEC 60189 and IEC 60708 ImprintSubject to technical modification.100 Zero halogen non corrosive gases Flame propagation Flame spread Smoke density Power over Ethernet plus EMC Cat./ClassDATWYLER cable type additional text batch number meter marksIEC 60754-1/-2, EN 50267-2-1/-2-2 (VDE 0482-267-2-1/-2-2) IEC 60332-1-2, EN 60332-1-2 (VDE 0482-332-1-2) IEC 60332-3-24, EN 60332-3-24 IEC 61034-1/-2, EN 61034-1/-2 (VDE 0482-1034-1/-2) IEEE 802.3at shielded better than Cat.7A / Class FAWirelessMechanical Characteristics10Fibre Optics204 Attenuation 7150Cabinets & Racks40Data Centre80MultimediaLoop resistance at 20 C: 111 /km Mutual capacitance: 41 pF/m Impedance at 100 MHz: 100 5 Transfer impedance at 1/10/30 MHz: < 5/5/8 m/m Coupling attenuation (limit curve of critical state IEC 61156): 85 dB Near end unbalance att. LCL: > 40 B d Delay skew: 17 ns/100m NVP: 80 %General InformationReturn loss [dB]These performance data are typical measured values.27 29. Copper data cables, shieldedData cable S/FTP Cat.7A AWG22 CU 7702 4P / 2x4P F8Screen Tinned braided copperWire 1.5 mm Screen pair Alu PETP foilOuter sheath FRNC/LS0H orange RAL 2003Inner conductor AWG22 Bare copper wireCopperProduct information Electrically and mechanically high-quality Cat.7A data cable - exceeds the requirements of ISO/IEC 11801, IEC 61156-5, IEC 61156-7, EN 50173-1 and prEN 50288-9-1. Excellent shielding effect due to individually screened pairs and overall copper braid. Easy identification of wires thanks to longitudinal colour markings. Compatible with all current connecting hardware in accordance with EN 50173 and ISO/IEC 11801.ApplicationsData cable for structured premises cabling. For the transmission of digital and analogue voice, video and data signals. Suitable for all ICT network applications up to class FA applications (1000 MHz) in accordance with EN 50173-1 and ISO/IEC 11801 and for the transmission of broadband signals (such as cable TV) in accordance with IEC 15018. Due to the increased wire section eminently suited for Power over Ethernet (PoE) / PoE+.Fibre OpticsFeaturesCabinets & RacksVersions DimensionSheathSheath Weight n x n x mm (AWG) mm kg/km1774004 x 2 x 0.62 (AWG22)FRNC/LS0H 1)177390 Data CentreArticle No. 2 x (4 x 2 x 0.62 (AWG22))FRNC/LS0H 1)FRNC/LS0H = Flame Retardant Non Corrosive / Low Smoke Zero Halogen28CU 7702 4P/2x4P 0312/eGeneral InformationMultimediaWireless1)Subject to technical modification.7.8 7.8 x 16.4Cu weightFire loadPU kg/km kWh/m MJ/m65.134.90.180.65131.069.80.361.301000 m drum 500 m drum 30. Copper data cables, shieldedData cable S/FTP Cat.7A AWG22CU 7702 4P / 2x4P F8Electrical Characteristics 5e66A7CATV7A101002505006008621000Category Frequency [MHz]1Attenuation [dB/100m]412001.73.45.316.9274042535662NEXT [dB]1031031031031039896929085PS NEXT [dB]1001001001001009593898782ACR-N [dB]101100988676585439342398979583735551363120PS-ACR-N [dB] ACR-F [dB]10910710593837065575446PS-ACR-F [dB]1061041029080676254514326303333282625242321 Copper[dB] 1401 NEXT 77021202 NEXT IEC 61156-5 Cat.7A1001803 Attenuation IEC 61156-5 Cat.7A2 6041 [MHz]General Characteristics1'00010'000 4P 2x4P F8 CU 7702 CU 7702 Bending radius (flat side) during draw-in: 64 mm 64 mm permanently installed: 32 mm 32 mm Tensile strength: 120 N 240 N Crush resistance: 1000 N/10 cm 1000 N/10 cm Impact: 10 impacts 10 impacts Temperature range during installation: 0 C to + 50 C 0 C to + 50 C in operation: -20 C to + 60 C -20 C to + 60 C Wire colour code white-blue/blue white-orange/orange white-green/green white-brown/brown (with longitudinal stripes) in accordance with IEC 60189 and IEC 60708 ImprintSubject to technical modification.100 Zero halogen non corrosive gases Flame propagation Flame spread Smoke density Power over Ethernet plus EMC Cat./ClassDATWYLER cable type additional text batch number meter marksIEC 60754-1/-2, EN 50267-2-1/-2-2 (VDE 0482-267-2-1/-2-2) IEC 60332-1-2, EN 60332-1-2 (VDE 0482-332-1-2) IEC 60332-3-24, EN 60332-3-24 IEC 61034-1/-2, EN 61034-1/-2 (VDE 0482-1034-1/-2) IEEE 802.3at shielded better than Cat.7A / Class FAWirelessMechanical Characteristics10Fibre Optics30Cabinets & Racks204 Attenuation 7702Data Centre40MultimediaLoop resistance at 20 C: 116 /km Mutual capacitance 43 pF/m Impedance at 100 MHz: 100 5 Transfer impedance at 1/10/30 MHz: < 5/5/8 m/m Coupling attenuation (limit curve of critical state IEC 61156): 85 dB Near end unbalance att. LCL: > 40dB Delay skew: 15 ns/100m NVP: 76 %General InformationReturn loss [dB]These performance data are typical measured values.29 31. Copper data cables, shieldedData cable S/FTP Cat.7A AWG23 CU 7120 4P / 2x4P F8Screen Tinned braided copperWire 1.5 mm Screen pair Alu PETP foilOuter sheath FRNC/LS0H orange RAL 2003Inner conductor AWG23 Bare copper wireCopperProduct information Electrically and mechanically high-quality Cat.7A data cable - exceeds the requirements of ISO/IEC 11801, IEC 61156-5, EN 50173-1 and prEN 50288-9-1. Excellent shielding effect due to individually screened pairs and overall copper braid. Reduced outer diameter. Compatible with all current connecting hardware in accordance with EN 50173 and ISO/IEC 11801.ApplicationsData cable for structured premises cabling. For the transmission of digital and analogue voice, video and data signals. Suitable for all ICT network applications up to class FA applications (1000 MHz) in accordance with EN 50173-1 and ISO/IEC 11801 and for the transmission of broadband signals (such as cable TV) in accordance with IEC 15018. Applicable for Power over Ethernet (PoE) / PoE+.Fibre OpticsFeaturesCabinets & RacksVersions DimensionSheathSheath Weight n x n x mm (AWG) mm kg/km1914664 x 2 x 0.59 (AWG23)FRNC/LS0H1)7.663.032.30.18 0.6491000 m drum191467 Data CentreArticle No. 2 x (4 x 2 x 0.59 (AWG23))FRNC/LS0H1)7.6 x 16.0126.064.60.36 1.298500 m drumFRNC/LS0H = Flame Retardant Non Corrosive / Low Smoke Zero Halogen30CU 7120 4P 0612/eGeneral InformationMultimediaWireless1)Subject to technical modification.Cu weightFire loadPU kg/km kWh/m MJ/m 32. Copper data cables, shieldedData cable S/FTP Cat.7A AWG23CU 7120 4P / 2x4P F8Electrical Characteristics5eCategory6A7CATV7A1410100250500600862100012001.83.55.417.7284146545764NEXT [dB]1031031031031039896929085PS NEXT [dB]1001001001001009593898782ACR-N [dB]101100988575575038332198979582725447353018ACR-F [dB]10810610492826964565346PS-ACR-F [dB]1051031018979666153504326303333282625242320[dB] 1401 NEXT 712012012 NEXT IEC 61156-5 Cat.7A1002 803 Attenuation IEC 61156-5 Cat.7A6044 Attenuation 712040 2030 1 [MHz]Mechanical CharacteristicsGeneral Characteristics101001'000 4P CU 7120 Bending radius (flat side) during draw-in: 60 mm permanently installed: 30 mm Tensile strength: 110 N Crush resistance: 1000 N/10 cm Impact resistance: 10 impacts Temperature range during installation: 0 C to +50 C in operation: -20 C to +60 C10'000CU 7120 2x4P F8 60 mm 30 mm 220 N 1000 N/10 cm 10 impacts 0 C to +50 C -20 C to +60 CWire colour code white/blue white/orange white/green white/brown according to IEC 60189 and IEC 60708 Imprint Zero halogen, non corrosive gases Flame propagation Flame spread Smoke density Power over Ethernet plus EMC Cat./ClassIEC 60754-1/-2, EN 50267-2-1/-2-2 (VDE 0482-267-2-1/-2-2) IEC 60332-1-2, EN 60332-1-2 (VDE 0482-332-1-2) IEC 60332-3-24, EN 60332-3-24 IEC 61034-1/-2, EN 61034-1/-2 (VDE 0482-1034-1/-2) IEEE 802.3at shielded Cat.7A / Class FAGeneral InformationDATWYLER cable type additional text batch number meter marksFibre OpticsLoop resistance at 20 C: 134 /km Mutual capacitance 44 pF/m Impedance at 100 MHz: 100 5 Transfer impedance at 1/10/30 MHz: < 5/5/8 m/m Coupling attenuation (limit curve of critical state IEC 61156): 85 dB Near end unbalance att. LCL: > 40 dB Delay skew: 14 ns/100 m NVP: 76 %CopperThese performance data are typical measured values.Cabinets & RacksReturn loss [dB]Data CentrePS-ACR-N [dB]WirelessAttenuation [dB/100m]MultimediaFrequency [MHz]6Subject to technical modification.31 33. Copper data cables, shieldedData cable S/FTP Cat.7 AWG23 CU 7080 4P / 2x4P F8Screen Tinned braided copperWire 1.4 mm Screen pair Alu PETP foilOuter sheath FRNC/LS0H orange RAL 2003Inner conductor AWG23 Bare copper wireCopperProduct information Electrically and mechanically high-quality Cat.7 data cable - exceeds the requirements of ISO/IEC 11801, IEC 61156-5, EN 50173-1 and EN 50288-4-1. Excellent shielding effect due to individually screened pairs and overall copper braid. Compatible with all current connecting hardware in accordance with EN 50173 and ISO/IEC 11801.ApplicationsData cable for structured premises cabling. For the transmission of digital and analogue voice, video and data signals. Suitable for all ICT network applications up to class F applications (600 MHz) in accordance with EN 50173-1 and ISO/IEC 11801 and for the transmission of broadband signals (such as cable TV) in accordance with IEC 15018. Applicable for Power over Ethernet (PoE) / PoE+.Fibre OpticsFeaturesCabinets & RacksVersions DimensionSheathSheath Weight n x n x mm (AWG) mm kg/km1829114 x 2 x 0.57 (AWG23)FRNC/LS0H 1)182912 Data CentreArticle No. 2 x (4 x 2 x 0.57 (AWG23))FRNC/LS0H 1)FRNC/LS0H = Flame Retardant Non Corrosive / Low Smoke Zero Halogen32CU 7080 4P/2x4P 0312/eGeneral InformationMultimediaWireless1)Subject to technical modification.7.4 7.4 x 15.6Cu weightFire loadPU kg/km kWh/m MJ/m6031.10.160.5712062.20.321.141000 m drum 500 m drum 34. Copper data cables, shieldedData cable S/FTP Cat.7 AWG23 CU 7080 4P / 2x4P F8Electrical Characteristics Category5eFrequency [MHz]166A71010025050060080086210001,93,75,617,92841465254571001001001001009290848380PS NEXT [dB]97979797978987818077ACR-N [dB]98969482725844322923PS-ACR-N [dB]95939179695541292620ACR-F [dB]98989878695645393733PS-ACR-F [dB]95959575665342363430Return loss [dB]26303333282625232220General Characteristics1 NEXT 708012011002 NEXT EN 50288-4-1803 Attenuation EN 50288-4-12 604204 Attenuation 708030 1 [MHz]101001'000 4P CU 7080 Bending radius (flat side) during draw-in: 60 mm permanently installed: 30 mm Tensile strength: 110 N Crush resistance: 1000 N/10 cm Impact: 10 impacts Temperature range during installation: 0 C to + 50 C in operation: -20 C to + 60C10'000CU 7080 2x4P F8 60 mm 30 mm 220 N 1000 N/10 cm 10 impacts 0 C to + 50 C -20 C to + 60 CWire colour code white/blue white/orange white/green white/brown in accordance with IEC 60189 and IEC 60708 Imprint Zero halogen, non corrosive gases Flame propagation Flame spread Smoke density Power over Ethernet plus EMC Cat./ClassIEC 60754-1/-2, EN 50267-2-1/-2-2 (VDE 0482-267-2-1/-2-2) IEC 60332-1-2, EN 60332-1-2 (VDE 0482-332-1-2) IEC 60332-3-24, EN 60332-3-24 IEC 61034-1/-2, EN 61034-1/-2 (VDE 0482-1034-1/-2) IEEE 802.3at shielded better than Cat.7 / Class FGeneral InformationDATWYLER cable type additional text batch number meter marksFibre Optics40Cabinets & RacksMechanical Characteristics[dB] 140Data CentreLoop resistance at 20 C: 140 /km Mutual capacitance: 42 pF/m Impedance at 100 MHz: 100 5 Transfer impedance at 1/10/30 MHz: < 6/6/10 m/m Coupling attenuation (limit curve of critical state IEC 61156): 85 dB Near end unbalance att. LCL at 1-600 MHz: > 40 dB Delay Skew: 12 ns/100 m NVP: 81 %CopperThese performance data are typical measured values.WirelessNEXT [dB]MultimediaAttenuation [dB/100m]4Subject to technical modification.33 35. Copper data cables, shieldedData cable S/FTP Cat.7 AWG23 CU 7002 4P / 2x4P F8Screen Tinned braided copperWire 1.4 mm Screen pair Alu PETP foilOuter sheath FRNC/LS0H orange RAL 2003Inner conductor AWG23 Bare copper wireCopperProduct information Electrically and mechanically high-quality Cat.7 data cable - exceeds the requirements of ISO/IEC 11801, IEC 61156-5, EN 50173-1 and EN 50288-4-1. Excellent shielding effect due to individually screened pairs and overall copper braid. Compatible with all current connecting hardware in accordance with EN 50173 and ISO/IEC 11801.ApplicationsData cable for structured premises cabling. For the transmission of digital and analogue voice, video and data signals. Suitable for all ICT network applications up to class F applications (600 MHz) in accordance with EN 50173-1 and ISO/IEC 11801 and for the transmission of broadband signals (such as cable TV) in accordance with IEC 15018. Applicable for Power over Ethernet (PoE) / PoE+.Fibre OpticsFeaturesCabinets & RacksVersionsDimensionSheathSheath Weight n x n x mm (AWG) mm kg/km1773884 x 2 x 0.57 (AWG23)FRNC/LS0H 1)177398 Data CentreArticle No. 2 x (4 x 2 x 0.57 (AWG23))FRNC/LS0H 1)FRNC/LS0H = Flame Retardant Non Corrosive/Low Smoke Zero Halogen34CU 7002 4P/2x4P 0312/eGeneral InformationMultimediaWireless1)Subject to technical modification.7.4 7.4 x 15.6Cu weightFire loadPU kg/km kWh/m MJ/m6031.10.160.5712062.20.321.141000 m drum 500 m drum 36. Copper data cables, shieldedData cable S/FTP Cat.7 AWG23 CU 7002 4P / 2x4P F8Electrical Characteristics Category5eFrequency [MHz]166A71010025050060080086210001.93.65.617.92841465254571001001001001009290848380PS NEXT [dB]97979797978987818077ACR-N [dB]98969482725844322923PS-ACR-N [dB]95939179695541292620ACR-F [dB]98989878695645393733PS-ACR-F [dB]95959575665342363430Return loss [dB]26303333282625232220General Characteristics1 NEXT 70021202 NEXT EN 50288-4-11001803 Attenuation EN 50288-4-12 604204 Attenuation 700230 1 [MHz]101001'000 4P CU 7002 Bending radius (flat side) during draw-in: 60 mm permanently installed: 30 mm Tensile strength: 110 N Crush resistance: 1000 N/10 cm Impact: 10 impacts Temperature range during installation: 0 C to + 50 C in operation: -20 C to + 60 C10'000CU 7002 2x4P F8 60 mm 30 mm 220 N 1000 N/10 cm 10 impacts 0 C to + 50 C -20 C to + 60 CWire colour code white/blue white/orange white/green white/brown in accordance with IEC 60189 and IEC 60708 Imprint Zero halogen, non corrosive gases Flame propagation Flame spread Smoke density Power over Ethernet plus EMC Cat./ClassIEC 60754-1/-2, EN 50267-2-1/-2-2 (VDE 0482-267-2-1/-2-2) IEC 60332-1-2, EN 60332-1-2 (VDE 0482-332-1-2) IEC 60332-3-24, EN 60332-3-24 IEC 61034-1/-2, EN 61034-1/-2 (VDE 0482-1034-1/-2) IEEE 802.3at shielded better than Cat.7 / Class FGeneral InformationDATWYLER cable type additional text batch number meter marksFibre Optics40Cabinets & RacksMechanical Characteristics[dB] 140Data CentreLoop resistance at 20 C: 140 /km Mutual capacitance: 42 pF/m Impedance at 100 MHz: 100 5 Transfer impedance at 1/10/30 MHz: < 6/6/10 m/m Coupling attenuation (limit curve of critical state IEC 61156): 85 dB Near end unbalance att. LCL at 1-600 MHz: > 40 dB Delay Skew: 4 ns/100 m NVP: 81%CopperThese performance data are typical measured values.WirelessNEXT [dB]MultimediaAttenuation [dB/100m]4Subject to technical modification.35 37. Copper data cables, shieldedData cable S/FTP Cat.7 AWG23 CU 7002 nx4P Breakout Light (BOL)Screen Tinned braided copperOuter foil of Breakout Light (BOL) construction Polyester foil, transparent, sealedWire 1.4 mm Screen pair Alu PETP foilSingle cable sheath FRNC/LS0H orange RAL 2003Inner conductor AWG23 Bare copper wireCopperProduct information Electrically and mechanically high-quality Cat.7 data cable - exceeds the requirements of ISO/IEC 11801, IEC 61156-5, EN 50173-1 and EN 50288-4-1. Excellent shielding effect due to individually screened pairs and overall copper braid. Easy handling, small outer diameter and reduced weight thanks to the Breakout Light construction with outer polyester foil instead of an overall cable sheath. Considerable shorter installation time due to the multi-cable construction Compatible with all current connecting hardware in accordance with EN 50173 and ISO/IEC 11801.ApplicationsFibre OpticsFeaturesData cable for structured premises cabling. For the transmission of digital and analogue voice, video and data signals. Suitable for all applications up to class F applications (600 MHz) in accordance with EN 50173-1 and ISO/IEC 11801 and for the transmission of broadband signals (such as cable TV) in accordance with IEC 15018. Applicable for Power over Ethernet (PoE) / PoE+. Especially suitable for Consolidation Points (e.g. in open-plan offices).Cabinets & RacksVersions Number of elements 4PSheathSheath Weight 1 x 4 x 0.57 (AWG 23) mm kg/km1829763 x 4PFRNC/LS0H 1)16.118593.31.711000 m drum1828744 x 4PFRNC/LS0H 1)18.0245124.42.281000 m drum188486Data CentreArticle No. 6 x 4PFRNC/LS0H 1)21.2390186.63.421000 m drumWirelessFRNC/LS0H = Flame Retardant Non Corrosive / Low Smoke Zero HalogenCU 7002 4P/nx4P BOL 0312/eMultimedia General InformationFireloadPU* MJ/m* 500 m und 2000 m drums on request 1)36Cu weight kg/kmSubject to technical modification. 38. Copper data cables, shieldedData cable S/FTP Cat.7 AWG23 CU 7002 nx4P Breakout LightElectrical Characteristics Category5eFrequency [MHz]166A7101002505006001.93.65.617.92841461001001001001009290PS NEXT [dB]97979797978987ACR-N [dB]98969482725844PS-ACR-N [dB]95939179695541ACR-F [dB]98989878695645PS-ACR-F [dB]95959575665342Return loss [dB]26303333282625General Characteristics1 NEXT 70021202 NEXT EN 50288-4-11001803 Attenuation EN 50288-4-12 604204 Attenuation 700230 1 [MHz]101001'00010'000 3x4P CU 7002 4x4P CU 7002 6x4P CU 7002 Bending radius (flat side) during draw-in: 130 mm 144 mm 170 mm permanently installed: 65 mm 72 mm 85 mm Tensile strength: 300 N 400 N 600 N Crush resistance: 1000 N/10 cm Impact: 10 impacts Temperature range during installation: 0 C to + 50 C in operation: -20 C to + 60 C Wire colour code white/blue white/orange white/green white/brown in accordance with IEC 60189 and IEC 60708 Imprint Zero halogen, non corrosive gases Flame propagation Flame spread Smoke density Power over Ethernet plus EMC Cat./ClassIEC 60754-1/-2, EN 50267-2-1/-2-2 (VDE 0482-267-2-1/-2-2) IEC 60332-1-2, EN 60332-1-2 (VDE 0482-332-1-2) IEC 60332-3-24, EN 60332-3-24 IEC 61034-1/-2, EN 61034-1/-2, (VDE 0482-1034-1/-2) IEEE 802.3at shielded better than Cat.7 / Class FGeneral InformationDATWYLER cable type additional text batch number meter marksFibre Optics40Cabinets & RacksMechanical Characteristics[dB] 140Data CentreLoop resistance at 20C: 140 /km Mutual capacitance: 42 pF/m Impedance at 100 MHz: 100 5 Transfer impedance at 1/10/30 MHz: < 6/6/10 m/m Coupling attenuation (limit curve of critical state IEC 61156): 85 dB Near end unbalance att. LCL at 1-600 MHz: > 40 dB Delay Skew: 12 ns/100 m NVP: 81%CopperThese performance data are typical measured values.WirelessNEXT [dB]MultimediaAttenuation [dB/100m]4Subject to technical modification.37 39. Copper data cables, shieldedIndustrial data cable S/FTP Cat.7 AWG23 CU 7002 4P Industrial PURScreen Tinned braided copperOuter sheath PUR orange RAL 2003Wire 1.4 mm Screen pair Alu PETP foilInner conductor AWG23 / 0.57 mm Bare copper wireCopperProduct information Electrically and mechanically high-quality Cat.7 data cable with PUR sheath - exceeds the requirements of ISO/IEC 11801, IEC 61156-5, EN 50173-1 and EN 50288-4-1. Compatible with Datwyler IP67 connecting hardware. Excellent shielding effect due to individually screened pairs and overall copper braid. Compatible with all current connecting hardware in accordance with EN 50173 and ISO/IEC 11801.ApplicationsData cable for structured premises cabling - designed for use in indoor and outdoor industrial areas. Oil resistant. For the transmission of digital and analogue voice, video and data signals. Suitable for all ICT network applications up to class F applications (600 MHz) in accordance with EN 50173-1 and ISO/IEC 11801. Applicable for Power over Ethernet (PoE) / PoE+.Fibre OpticsFeaturesCabinets & RacksVersions DimensionSheathSheath Weight n x n x mm (AWG) mm kg/km187689Data CentreArticle No. 4 x 2 x 0.57 (AWG23)PUR = Polyurethane38CU 7002 4P industrial PUR 0312/eGeneral InformationMultimediaWireless1)Subject to technical modification.PUR 1)7.973.9Cu weightFire loadPU kg/km kWh/m MJ/m 31.10.190.701000 m drum 40. Copper data cables, shieldedIndustrial data cable S/FTP Cat.7 AWG23 CU 7002 4P Industrial PURElectrical Characteristics Category Frequency [MHz]466A7101002505006001.93.65.617.92841461001001001001009290PS NEXT [dB]97979797978987ACR [dB]98969482725844PS ACR [dB]95939179695541ELFEXT [dB]98989878695645PS ELFEXT [dB]95959575665342Return loss [dB]26303333282625[dB] 1401 NEXT 70021202 NEXT EN 50288-4-11001803 Attenuation EN 50288-4-12 60430 1 [MHz]101001'000Mechanical CharacteristicsBending radius during draw-in: permanently installed: Tensile strength: Crush resistance: Impact: Temperature range during installation: in operation: General Characteristics10'000Wire colour code white/blue white/orange white/green white/brown in accordance with IEC 60189 and IEC 60708 ImprintDATWYLER cable type additional text batch number meter marks IEC 60754-1/-2, EN 50267-2-1/-2-2 (VDE 0482-267-2-1/-2-2) IEC 60332-1-2, EN 60332-1-2 (VDE 0482-332-1-2) EN 60811-2-1 IEEE 802.3at shielded better than Cat.7 / Class FGeneral Information Zero halogen Flame propagation Oil-resistant Power over Ethernet plus EMC Cat./Class 60 mm 30 mm 110 N 1000 N/10 cm 10 impacts 0 C to + 50 C -30 C to + 60 CFibre Optics204 Attenuation 7002Cabinets & Racks40Data CentreLoop resistance at 20 C: 140 /km Mutual capacitance: 42 pF/m Impedance at 100 MHz: 100 5 Transfer impedance at 1/10/30 MHz: < 6/6/10 m/m Coupling attenuation (limit curve of critical state IEC 61156) 85 dB Near end unbalance att. LCL at 1-600 MHz: > 40 dB Delay Skew: 12 ns/100 m NVP: 81 %CopperThese performance data are typical measured values.WirelessNEXT [dB]MultimediaAttenuation [dB/100m]5e 1Subject to technical modification.39 41. Copper data cables, shieldedData cable S/FTP Cat.7 AWG23 CU 7002 4P GG-PE with rodent protection and PE cable sheethRodent protection with glass rovingsOuter sheath PE blackScreen pair Alu PETP foilRipcordOuter sheath FRNC/LS0H orange RAL 2003Wire 1.4 mm Screen Tinned braided copperInner conductor AWG 23 Bare copper wireCopperProduct informationCabinets & RacksApplicable for outdoor installation due to rodent protection and PE outer cable sheath with higher UV resistance. Robust cable design with a high mechanical stability. Electrically and mechanically high-quality Cat.7 data cable - exceeds the requirements of ISO/IEC 11801, IEC 61156-5, EN 50173-1 and EN 50288-4-1. Excellent shielding effect due to individually screened pairs and overall copper braid. Compatible with all current connecting hardware in accordance with EN 50173 and ISO/IEC 11801.ApplicationsFibre OpticsFeaturesData cable for structured premises and outdoor cabling. With rodent protection and increased UV protection (due to PE outer sheath). For the transmission of digital and analogue voice, video and data signals. Suitable for all ICT network applications up to class F applications (600 MHz) in accordance with EN 50173-1 and ISO/IEC 11801. Applicable for Power over Ethernet (PoE) / PoE+.Versions DimensionSheathSheath Weight n x n x mm (AWG) mm kg/km191923Data CentreArticle No. 4 x 2 x 0.57 (AWG23)FRNC/LS0H = Flame Retardant Non Corrosive /L ow Smoke Zero Halogen40CU 7002 4P GG-PE 0312/eGeneral InformationMultimediaWireless1)FRNC/LS0H-PE 1)Subject to technical modification.11.6141Cu weightFire loadPU kg/km kWh/m MJ/m 31.10.75 2.69on equest r 42. Copper data cables, shieldedData cable S/FTP Cat.7 AWG23 CU 7002 4P GG-PE with rodent protection and PE cable sheethElectrical Characteristics Category5eFrequency [MHz]166A7101002505006001.93.65.617.92841461001001001001009290PS NEXT [dB]97979797978987ACR-N [dB]98969482725844PS-ACR-N [dB]95939179695541ACR-F [dB]98989878695645PS-ACR-F [dB]95959575665342Return loss [dB]26303333282625[dB] 1401 NEXT 70021202 NEXT EN 50288-4-11001803 Attenuation EN 50288-4-12 60430 1 [MHz]Mechanical CharacteristicsGeneral Characteristics101001'00010'000 Bending radius during draw-in: 92 mm permanently installed: 46 mm Tensile strength: 150 N Crush resistance: 2000 N/10 cm Impact: 20 impacts Temperature range during installation: 0 C to + 50 C in operation: -20 C to + 60 C Wire colour code white/blue white/orange white/green white/brown in accordance with IEC 60189 and IEC 60708 ImprintIEC 60754-1/-2, EN 50267-2-1/-2-2 (VDE 0482-267-2-1/-2-2) IEC 61034-1/-2, EN 61034-1/-2 (VDE 0482-1034-1/-2) IEEE 802.3at shielded better than Cat.7 / Class FGeneral Information Zero halogen, non corrosive gases Smoke density Power over Ethernet plus EMC Cat./ClassDATWYLER cable type additional text batch number meter marksFibre Optics204 Attenuation 7002Cabinets & Racks40Data CentreLoop resistance at 20 C: 140 /km Mutual capacitance: 42 pF/m Impedance at 100 MHz: 100 5 Coupling attenuation (limit curve of critical state IEC 61156): 85 dB Near end unbalance att. LCL at 1-600 MHz: >40 dB Delay Skew: 12 ns/100 m NVP: 81%CopperThese performance data are typical measured values.WirelessNEXT [dB]MultimediaAttenuation [dB/100m]4Subject to technical modification.41 43. Copper data cables, shieldedData cable F/FTP Cat.7 AWG23 CU 7052 4P / 2x4P F8Drain wire Tinned copper wireScreen Alu PETP foilOuter sheath FRNC/LS0H orange RAL 2003Wire 1.6 mm Screen pair Alu PETP foilInner conductor AWG23 Bare copper wireCopperProduct information Electrically and mechanically high-quality Cat.7 data cable - exceeds the requirements of ISO/IEC 11801, IEC 61156-5, EN 50173-1 and EN 50288-4-1. Excellent shielding effect due to individually screened pairs and overall foil screen. Compatible with all current connecting hardware in accordance with EN 50173 and ISO/IEC 11801.ApplicationsData cable for structured premises cabling. For the transmission of digital and analogue voice, video and data signals. Suitable for all ICT network applications up to class F applications (600 MHz) in accordance with EN 50173-1 and ISO/IEC 11801 and for the transmission of broadband signals (such as cable TV) in accordance with IEC 15018. Applicable for Power over Ethernet (PoE) / PoE+.Fibre OpticsFeaturesCabinets & RacksVersions DimensionSheathSheath Weight n x n x mm (AWG) mm kg/km1829114 x 2 x 0.57 (AWG23)FRNC/LS0H 1)182912 Data CentreArticle No. 2 x (4 x 2 x 0.57 (AWG23))FRNC/LS0H 1)FRNC/LS0H = Flame Retardant Non Corrosive / Low Smoke Zero Halogen42CU 7052 4P/2x4P 0712/eGeneral InformationMultimediaWireless1)Subject to technical modification.7.4 7.4 x 15.6Cu weightFire loadPU kg/km kWh/m MJ/m6031.10.160.5712062.20.321.141000 m drum 500 m drum 44. Copper data cables, shieldedData cable F/FTP Cat.7 AWG23 CU 7052 4P / 2x4P F8Electrical Characteristics 5e66A71410100250500600862Attenuation [dB/100m]1,93,75,617,928414654NEXT [dB]9898989898908881PS NEXT [dB]9595959595878578ACR-N [dB]9694928070564227PS-ACR-N [dB]9391897767533924ACR-F [dB]9696967668544335PS-ACR-F [dB]9393937364514032Return loss [dB]2428313126242320[dB] 1401 NEXT 705212011002 NEXT EN 50288-4-1803 Attenuation EN 50288-4-12 6040 1 [MHz]Mechanical CharacteristicsGeneral Characteristics101001'000 4P CU 7052 Bending radius (flat side) during draw-in: 60 mm permanently installed: 30 mm Tensile strength: 110 N Crush resistance: 1000 N/10 cm Impact: 10 impacts Temperature range during installation: 0 C to + 50 C in operation: -20 C to + 60C10'000CU 7052 2x4P F8 60 mm 30 mm 220 N 1000 N/10 cm 10 impacts 0 C to + 50 C -20 C to + 60 CWire colour code white/blue white/orange white/green white/brown in accordance with IEC 60189 and IEC 60708 ImprintDATWYLER cable type additional text batch number meter marks Zero halogen, non corrosive gases Flame propagation Flame spread Smoke density Power over Ethernet plus EMC Cat./ClassIEC 60754-1/-2, EN 50267-2-1/-2-2, VDE 0482-267-2-1/-2-2 IEC 60332-1-2, EN 60332-1-2, VDE 0482-332-1-2 IEC 60332-3-24, EN 50266-24 Cat. C, VDE 0482-266-2-4 Cat. C IEC 61034-1/-2, EN 61034-1/-2 (EN 50268-1/-2), VDE 0482-1034-1/-2 (VDE 0482-268)-1/-2) IEEE 802.3at shielded better than Cat.7 / Class FGeneral InformationFibre Optics3Cabinets & Racks204 Attenuation 7052Data Centre40WirelessLoop resistance at 20 C: 140 /km Mutual capacitance: 42 pF/m Impedance at 100 MHz: 100 5 Coupling attenuation (limit curve of critical state IEC 61156): 75 dB Near end unbalance att. LCL: > 40 dB Delay Skew: 12 ns/100 m NVP: 81 %CopperThese performance data are typical measured values.MultimediaCategory Frequency [MHz]Subject to technical modification.43 45. Copper data cables, shieldedData cable S/FTP Cat.6A AWG23 CU 7060 4P / 2x4P F8Screen Tinned braided copperWire 1.3 mm Screen pair Alu PETP foilOuter sheath FRNC/LS0H orange RAL 2003Inner conductor AWG23 Bare copper wireCopperProduct information Electrically and mechanically high-quality Cat.6A data cable - exceeds the requirements of ISO/IEC 11801, IEC 61156-5, EN 50173-1 and prEN 50288-10-1. Excellent shielding effect due to individually screened pairs and overall copper braid. Compatible with all current connecting hardware in accordance with EN 50173 and ISO/IEC 11801.ApplicationsData cable for structured premises cabling. For the transmission of digital and analogue voice, video and data signals. Suitable for all ICT network applications up to class EA applications (500 MHz) in accordance with EN 50173-1 and ISO/IEC 11801. Applicable for Power over Ethernet (PoE) / PoE+.Fibre OpticsFeaturesCabinets & RacksVersionsDimensionSheathSheath Weight n x n x mm (AWG) mm kg/km1829244 x 2 x 0.55 (AWG23)FRNC/LS0H1)7.155.026.40.1520.551000 m drum182927 Data CentreArticle No. 2 x (4 x 2 x 0.55 (AWG23))FRNC/LS0H1)7.1 x 15110.052.80.3041.10500 m drumFRNC/LS0H = Flame Retardant Non Corrosive /L ow Smoke Zero Halogen44CU 7060 4P 0312/eGeneral InformationMultimediaWireless1)Subject to technical modification.Cu weightFire loadPU kg/km kWh/m MJ/m 46. Copper data cables, shieldedData cable S/FTP Cat.6A AWG23CU 7060 4P / 2x4P F8Electrical Characteristics 5e66A1410100250500600Attenuation [dB/100m]2.13.85.919.8304347NEXT [dB]93939393827775PS NEXT [dB]90909090797472ACR-N [dB]91898773523428PS-ACR-N [dB]88868470493125ACR-F [dB]96969674614339PS-ACR-F [dB]93939371584036Return loss [dB]26283030272524[dB] 1401 NEXT 70601202 NEXT EN 50288-4-1100 803 Attenuation EN 50288-4-112604 Attenuation 7060401 [MHz]Mechanical CharacteristicsGeneral Characteristics101001'000 4P CU 7060 Bending radius during draw-in: 65 mm permanently installed: 30 mm Tensile strength: 95 N Crush resistance: 1000 N/10 cm Impact: 10 impacts Temperature range during installation: 0 C to + 50 C in operation: -20 C to + 60 C10'000CU 7060 2x4P F8 65 mm 30 mm 190 N 1000 N/10 cm 10 impacts 0 C to + 50 C -20 C to + 60 CWire colour code white/blue white/orange white/green white/brown in accordance with IEC 60189 and IEC 60708 ImprintDATWYLER cable type additional text batch number meter marks Zero halogen, non corrosive gases Flame propagation Flame spread Smoke density Power over Ethernet EMC Cat./Class IEC 60754-1/-2, EN 50267-2-1/-2-2 (VDE 0482-267-2-1/-2-2) IEC 60332-1-2, EN 60332-1-2 (VDE 0482-332-1-2) IEC 60332-3-24, EN 60332-3-24 IEC 61034-1/-2, EN 61034-1/-2 (VDE 0482-1034-1/-2) IEEE 802.3af shielded better than Cat.6A (typical values of Cat.7 for lengths up to ~70 m) Class EASubject to technical modification.Cabinets & Racks0Data Centre3Wireless20Fibre Optics4MultimediaLoop resistance at 20 C: 146 /km Mutual capacitance: 42 pF/m Impedance at 100 MHz: 100 5 Transfer impedance at 1/10/30 MHz: < 6/10/20 m/m Coupling attenuation (limit curve of critical state IEC 61156): 75 dB Near end unbalance att. LCL: >40 dB Delay Skew: 4 ns/100 m NVP: 80 %CopperThese performance data are typical measured values.General InformationCategory Frequency [MHz]45 47. Copper data cables, shieldedData cable F/FTP Cat.6A AWG23 CU 6552 4P / 2x4P F8Drain wire Tinned copper wireScreen Alu PETP foilOuter sheath FRNC/LS0H orange RAL 2003Wire 1.3 mm Screen pair Alu PETP foilInner conductor AWG23 Bare copper wireCopperProduct information Electrically and mechanically high-quality Cat.6A data cable - exceeds the requirements of ISO/IEC 11801, IEC 61156-5, EN 50173-1 and prEN 50288-10-1. Excellent shielding effect due to individually screened pairs and overall foil screen. Compatible with all current connecting hardware in accordance with EN 50173 and ISO/IEC 11801.ApplicationsData cable for structured premises cabling. For the transmission of digital and analogue voice, video and data signals. Suitable for all ICT network applications up to class EA applications (500 MHz) in accordance with EN 50173-1 and ISO/IEC 11801. Applicable for Power over Ethernet (PoE) / PoE+.Fibre OpticsFeaturesCabinets & RacksVersionsDimensionSheathSheath Weight n x n x mm (AWG) mm kg/km1914544 x 2 x 0.55 (AWG 23)FRNC/LS0H 1)191456 Data CentreArticle No. 2 x (4 x 2 x 0.55 (AWG 23))FRNC/LS0H 1)FRNC/LS0H = Flame Retardant Non Corrosive / Low Smoke Zero Halogen46CU 6552 4P 0312/eGeneral InformationMultimediaWireless1)Subject to technical modification.7.0 7.0 x 14.3Cu weightFire loadPU kg/km kWh/m MJ/m48.520.00.140.5297.040.00.281.041000 m drum 500 m drum 48. Copper data cables, shieldedData cable F/FTP Cat.6A AWG23CU 6552 4P / 2x4P F8Electrical Characteristics 5e66A1410100250500Attenuation [dB/100m]2.13.85.919.03043NEXT [dB]939393938375PS NEXT [dB]909090908072ACR-N [dB]918987735332PS-ACR-N [dB]888684705029ACR-F [dB]969696745633PS-ACR-F [dB]939393715330Return loss [dB]2628303027212 NEXT IEC 61156 Cat.6A100 803 Attenuation IEC 61156 Cat.6A12604 Attenuation 655240 2030 1 [MHz]10 Bending radius during draw-in: permanently installed: Tensile strength: Crush resistance: Impact: Temperature range during installation: in operation:1001'000CU 6552 4P 56 mm 28 mm 95 N 1000 N/10 cm 10 impacts 0 C to + 50 C -20 C to + 60 C10'000CU 6552 2x4P F8 56 mm 28 mm 190 N 1000 N/10 cm 10 impacts 0 C to + 50 C -20 C to + 60 CWire colour code white/blue white/orange white/green white/brown in accordance with IEC 60189 and IEC 60708 Imprint Zero halogen, non corrosive gases Flame propagation Flame spread Smoke density Power over Ethernet EMC Cat./ClassIEC 60754-1/-2, EN 50267-2-1/-2-2 (VDE 0482-267-2-1/-2-2) IEC 60332-1-2, EN 60332-1-2 (VDE 0482-332-1-2) IEC 60332-3-24, EN 60332-3-24 IEC 61034-1/-2, EN 61034-1/-2 (VDE 0482-1034-1/-2) IEEE 802.3af shielded Cat.6A / Class EAGeneral InformationDATWYLER cable type additional text batch number meter marksFibre Optics4Cabinets & RacksGeneral Characteristics1 NEXT 6552120Data CentreMechanical Characteristics[dB] 140WirelessLoop resistance at 20 C: 150 /km Mutual capacitance: 42 pF/m Impedance at 100 MHz: 100 5 Transfer impedance at 1/10/30 MHz: < 50/100/200 m/m Coupling attenuation (limit curve of critical state IEC 61156): 70 dB Near end unbalance attenuation LCL: >40 dB Delay Skew: 5 ns/100 m NVP: 79 %CopperThese performance data are typical measured values.MultimediaCategory Frequency [MHz]Subject to technical modification.47 49. Copper data cables, shieldedData cable U/FTP Cat.6A AWG23 CU 6502 4P / 2x4P F8Drain wire Tinned copper wireWire 1.3 mm Screen pair Alu PETP foilOuter sheath FRNC/LS0H orange RAL 2003Inner conductor AWG23 Bare copper wireCopperProduct information Electrically and mechanically high-quality Cat.6A data cable - exceeds the requirements of ISO/IEC 11801, IEC 61156-5, EN 50173-1 and prEN 50288-10-1. Good shielding effect due to individually screened pairs. Compatible with all current connecting hardware in accordance with EN 50173 and ISO/IEC 11801.ApplicationsData cable for structured premises cabling. For the transmission of digital and analogue voice, video and data signals. Suitable for all ICT network applications up to class EA applications (500 MHz) in accordance with EN 50173-1 and ISO/IEC 11801. Applicable for Power over Ethernet (PoE) / PoE+.Fibre OpticsFeaturesCabinets & RacksArticle No. DimensionSheathSheath Weight n x n x mm (AWG) mm kg/km1914534 x 2 x 0.55 (AWG 23)FRNC/LS0H 1)1914552 x (4 x 2 x 0.55 (AWG 23))FRNC/LS0H 1)Data CentreVersions1)48CU 6502 4P 0312/eGeneral InformationMultimediaWirelessFRNC/LS0H = Flame Retardant Non Corrosive /L ow Smoke Zero HalogenSubject to technical modification.7.0 7.0 x 14.3Cu weightFire loadPU kg/km kWh/m MJ/m47.820.00.150.5595.640.00.301.101000 m drum 500 m drum 50. Copper data cables, shieldedData cable U/FTP Cat.6A AWG23CU 6502 4P / 2x4P F8Electrical Characteristics 5e66A1410100250500Attenuation [dB/100m]2.13.85.919.03043NEXT [dB]939393938375PS NEXT [dB]909090908072ACR-N [dB]918987735332PS-ACR-N [dB]888684705029ACR-F [dB]969696745633PS-ACR-F [dB]939393715330Return loss [dB]2628303027212 NEXT IEC 61156 Cat.6A10013 Attenuation IEC 61156 Cat.6A602440 204 Attenuation 650230 1 [MHz]10 Bending radius during draw-in: permanently installed: Tensile strength: Crush resistance: Impact: Temperature range during installation: in operation:1001'000CU 6502 4P 56 mm 28 mm 95 N 1000 N/10 cm 10 impacts 0 C to + 50 C -20 C to + 60 C10'000CU 6502 2x4P F8 56 mm 28 mm 190 N 1000 N/10 cm 10 impacts 0 C to + 50 C -20 C to + 60 CWire colour code white/blue white/orange white/green white/brown in accordance with IEC 60189 and IEC 60708 Imprint Zero halogen, non corrosive gases Flame propagation Smoke density Power over Ethernet EMC Cat./ClassDATWYLER cable type additional text batch number meter marksIEC 60754-1/-2, EN 50267-2-1/-2-2 (VDE 0482-267-2-1/-2-2) IEC 60332-1-2, EN 60332-1-2 (VDE 0482-332-1-2) IEC 61034-1/-2, EN 61034-1/-2 (VDE 0482-1034-1/-2) IEEE 802.3af shielded Cat.6A / Class EAGeneral InformationFibre Optics80Cabinets & RacksGeneral Characteristics1 NEXT 6502120Data CentreMechanical Characteristics[dB] 140WirelessLoop resistance at 20 C: 150 /km Mutual capacitance: 42 pF/m Impedance at 100 MHz: 100 5 Transfer impedance at 1/10/30 MHz: < 50/100/200 m/m Coupling attenuation (limit curve of critical state IEC 61156): 55 dB Near end unbalance attenuation LCL: >40 dB Delay Skew: 5 ns/100 m NVP: 79 %CopperThese performance data are typical measured values.MultimediaCategory Frequency [MHz]Subject to technical modification.49 51. Copper data cables, shieldedData cable F/FTP Cat.6 AWG23 CU 6052 4P / 2x4P F8Drain wire Tinned copper wireScreen Alu PETP foilOuter sheath FRNC/LS0H orange RAL 2003Wire 1.3 mm Screen pair Alu PETP foilInner conductor AWG23 Bare copper wireCopperProduct information Electrically and mechanically high-quality Cat.6 data cable - fulfils the requirements of ISO/IEC 11801, IEC 61156-5, EN 50173-1 and EN 50288-5-1. Good shielding effect due to individually screened pairs and overall foil screen. Compatible with all current connecting hardware in accordance with EN 50173 and ISO/IEC 11801.ApplicationsData cable for structured premises cabling. For the transmission of digital and analogue voice, video and data signals. Suitable for all ICT network applications up to class E applications (250 MHz) in accordance with EN 50173-1 and ISO/IEC 11801. Applicable for Power over Ethernet (PoE) / PoE+.Fibre OpticsFeaturesCabinets & RacksVersionsDimensionSheathSheath Weight n x n x mm (AWG) mm kg/km188512 4 x 2 x 0.55 (AWG 23) FRNC/LS0H 1)7.0 48.7 20.0 0.144 0.517 1000 m drum188513 Data CentreArticle No. 2 x (4 x 2 x 0.55 (AWG 23)) FRNC/LS0H 1) 7.0 x 14.8 97.7 40.0 0.225 0.810 500 m drumFRNC/LS0H = Flame Retardant Non Corrosive / Low Smoke Zero Halogen50CU 6052 4P 0312/eGeneral InformationMultimediaWireless1)Subject to technical modification.Cu weightFire loadPU kg/km kWh/m MJ/m 52. Copper data cables, shieldedData cable F/FTP Cat.6 AWG23 CU 6052 4P / 2x4P F8Electrical Characteristics 5e61410100250300Attenuation [dB/100m]2.13.85.919.83032NEXT [dB]939393938380PS NEXT [dB]909090908079ACR-N [dB]918987735348PS-ACR-N [dB]888684705045ACR-F [dB]969696745649PS-ACR-F [dB]939393715346Return loss [dB]2628303027262 NEXT EN 50288-5-1100 8013 Attenuation IEN 50288-5-126020430 1 [MHz]101001'000 4P CU 6052 Bending radius during draw-in: 56 mm permanently installed: 28 mm Tensile strength: 95 N Crush resistance: 1000 N/10 cm Impact: 10 impacts Temperature range during installation: 0 C to + 50 C in operation: -20 C to + 60 C10'000CU 6052 2x4P F8 56 mm 28 mm 190 N 1000 N/10 cm 10 impacts 0 C to + 50 C -20 C to + 60 CWire colour code white/blue white/orange white/green white/brown in accordance with IEC 60189 and IEC 60708 Imprint Zero halogen, non corrosive gases Flame propagation Flame spread Smoke density Power over Ethernet EMC Cat./ClassIEC 60754-1/-2, EN 50267-2-1/-2-2 (VDE 0482-267-2-1/-2-2) IEC 60332-1-2, EN 60332-1-2 (VDE 0482-332-1-2) IEC 60332-3-24, EN 60332-3-24 IEC 61034-1/-2, EN 61034-1/-2 (VDE 0482-1034-1/-2) IEEE 802.3af shielded Cat.6 / Class EGeneral InformationDATWYLER cable type additional text batch number meter marksFibre Optics4 Attenuation 605240Cabinets & RacksGeneral Characteristics1 NEXT 6052120Data CentreMechanical Characteristics[dB] 140WirelessLoop resistance at 20 C: 150 /km Mutual capacitance: 42 pF/m Impedance at 100 MHz: 100 5 Transfer impedance at 1/10/30 MHz: < 50/100/200 m/m Coupling attenuation (limit curve of critical state IEC 61156): 65 dB Near end unbalance attenuation LCL: >40 dB Delay Skew: 5 ns/100 m NVP: 79 %CopperThese performance data are typical measured values.MultimediaCategory Frequency [MHz]Subject to technical modification.51 53. Copper data cables, shieldedData cable SF/UTP Cat.6 AWG24 CU 6702 4PStabilising element designed forWire 1.0 mm PE-Foam-Skin robustness quick and easy termination stable electrical performanceOuter sheath FRNC/LS0H orange RAL 2003Screen Tinned braided copperScreen Alu/PETP foilInner conductor AWG 24 Bare copper wireCopperProduct information FeaturesElectrically and mechanically high-quality Cat.6 data cable - fulfils the requirements of ISO/IEC 11801, IEC 61156-5, EN 50173-1 und EN 50288-5-1. Robust cable design with a very high mechanical stability and reliable electrical performance thanks to the stabilising element. Excellent shielding effect due to overall foil and copper braid.Fibre OpticsSimple, fast and reliable terminations thanks to the special cable stripper Abi 62.Article No. 185640Tool is applicable for 1. removal of outer sheath 2. removal of stabilising element from pairsCompatible with all current connecting hardware in accordance with EN 50173 and ISO/IEC 11801. ApplicationsData CentreCabinets & RacksData cable for structured premises cabling. For the transmission of digital and analogue voice, video and data signals. Suitable for all ICT network applications up to class E applications (250 MHz) in accordance with EN 50173-1 and ISO/IEC 11801. Applicable for Power over Ethernet (PoE) / PoE+.Versions DimensionSheathSheath Weight n x n x mm (AWG) mm kg/km182943WirelessArticle No. 4 x 2 x 0.54 (AWG24)FRNC/LS0H = Flame Retardant Non Corrosive / Low Smoke Zero Halogen52CU 6702 4P 0312/eGeneral InformationMultimedia1)FRNC/LS0H 1)Subject to technical modification.7.463.7Cu weightFire loadPU kg/km kWh/m MJ/m 27.70.250.891000 m drum 54. Copper data cables, shieldedData cable SF/UTP Cat.6 AWG24 CU 6702 4PElectrical Characteristics 5e61410100250300Attenuation [dB/100m]1.83.45.117.22630NEXT [dB]847571504340PS NEXT [dB]817268474037ACR-N [dB]827266331710PS-ACR-N [dB]79696330147ACR-F [dB]908071423531PS-ACR-F [dB]877768393228Return loss [dB]2730323025252 NEXT EN 50288-5-1100 803 Attenuation EN 50288-5-16012204 Attenuation 6702 430 1 [MHz]101001'00010'000Bending radius during draw-in: 58 mm permanently installed: 29 mm Tensile strength: 110 N Crush resistance: 3000 N/10 cm Impact: 30 impacts Temperature range during installation: 0 C to + 50 C in operation: -20 C to + 60 C Wire colour code white - blue/blue white - orange/orange white - green/green white - brown/brown in accordance with IEC 60189 and IEC 60708 (ring marked) Imprint Zero halogen, non corrosive gases Flame propagation Flame spread Smoke density Power over Ethernet EMC Cat./ClassIEC 60754-1/-2, EN 50267-2-1/-2-2 (VDE 0482-267-2-1/-2-2) IEC 60332-1-2, EN 60332-1-2 (VDE 0482-332-1-2) IEC 60332-3-24, EN 60332-3-24 IEC 61034-1/-2, EN 61034-1/-2 (VDE 0482-1034-1/-2) IEEE 802.3af shielded better than Cat.6 / Class EGeneral InformationDATWYLER cable type additional text batch number meter marksFibre Optics40Cabinets & RacksGeneral Characteristics1 NEXT 6702120Data CentreMechanical Characteristics[dB] 140WirelessLoop resistance at 20 C: 157 /km Mutual capacitance: 50 pF/m Impedance at 100 MHz: 100 5 Transfer impedance at 1/10/30 MHz: 40 dB Delay Skew: 25 ns/100 m NVP: 68 %CopperThese performance data are typical measured values.MultimediaCategory Frequency [MHz]Subject to technical modification.53 55. Copper data cables, shieldedData cable U/FTP Cat.6 AWG23 CU 6002 4PDrain wire Tinned copper wireWire 1.3 mm Screen pair Alu PETP foilOuter sheath FRNC/LS0H orange RAL 2003Inner conductor AWG23 Bare copper wireCopperProduct information Electrically and mechanically high-quality Cat.6 data cable - fulfils the requirements of ISO/IEC 11801, IEC 61156-5, EN 50173-1 and EN 50288-5-1. Good shielding effect due to individually screened pairs. Compatible with all current connecting hardware in accordance with EN 50173 and ISO/IEC 11801.ApplicationsData cable for structured premises cabling. For the transmission of digital and analogue voice, video and data signals. Suitable for all ICT network applications up to class E applications (250 MHz) in accordance with EN 50173-1 and ISO/IEC 11801. Applicable for Power over Ethernet (PoE) / PoE+.Fibre OpticsFeaturesVersionsDimensionSheathSheath Weight n x n x mm (AWG) mm kg/km182936Cabinets & RacksArticle No. 4 x 2 x 0.55 (AWG 23)FRNC/LS0H = Flame Retardant Non Corrosive / Low Smoke Zero Halogen54CU 6002 4P 0312/eGeneral InformationMultimediaWirelessData Centre1)FRNC/LS0H 1)Subject to technical modification.7.047.8Cu weightFire loadPU kg/km kWh/m MJ/m 20.00.150.551000 m drum 56. Copper data cables, shieldedData cable U/FTP Cat.6 AWG23 CU 6002 4PElectrical Characteristics 5e61410100250Attenuation [dB/100m]2.13.85.919.830NEXT [dB]9393939383PS NEXT [dB]9090909080ACR-N [dB]9189877353PS-ACR-N [dB]8886847050ACR-F [dB]9696967456PS-ACR-F [dB]9393937153Return loss [dB]2628303027[dB] 1401 NEXT 60021202 NEXT EN 50288-2-21001803 Attenuation EN 50288-2-22604 30 101001'000Mechanical CharacteristicsBending radius during draw-in: permanently installed: Tensile strength: Crush resistance: Impact: Temperature range during installation: in operation:General Characteristics10'000Wire colour code white/blue white/orange white/green white/brown in accordancce with IEC 60189 and IEC 60708 Imprint Zero halogen, non corrosive gases Flame propagation Smoke density Power over Ethernet EMC Cat./ClassDATWYLER cable type additional text batch number meter marksIEC 60754-1/-2, EN 50267-2-1/-2-2 (VDE 0482-267-2-1/-2-2) IEC 60332-1-2, EN 60332-1-2 (VDE 0482-332-1-2) IEC 61034-1/-2, EN 61034-1/-2 (VDE 0482-1034-1/-2) IEEE 802.3af shielded Cat.6 / Class EGeneral Information 56 mm 28 mm 95 N 1000 N/10 cm 10 impacts 0 C to + 50 C -20 C to + 60 C Cabinets & Racks1 [MHz]Data Centre20Fibre Optics4 Attenuation 600240WirelessLoop resistance at 20 C: 150 /km Mutual capacitance: 42 pF/m Impedance at 100 MHz: 100 5 Transfer impedance at 1/10/30 MHz: < 50/100/200 m/m Coupling attenuation (limit curve of critical state IEC 61156): 55 dB Near end unbalance attenuation LCL:> 40 dB Delay Skew: 5 ns/100 m NVP: 79 %CopperThese performance data are typical measured values.MultimediaCategory Frequency [MHz]Subject to technical modification.55 57. Copper data cables, shieldedData cable SF/UTP Cat.5e AWG24 CU 5502 4PPolyester foilOuter sheath FR/PVC grey RAL 7035 FRNC/LS0H orange RAL 2003Screen Tinned braided copperWire 1.0 mm , PE Foam SkinScreen Alu Polyester foilInner conductor AWG24 Bare copper wireCopperProduct information Electrically and mechanically high-quality Cat 5e data cable - fulfils the requirements of ISO/IEC 11801, IEC 61156-5, EN 50173-1 and EN 50288-2-1. Excellent shielding effect due to overall foil and copper braid. Compatible with all current connecting hardware in accordance with EN 50173 and ISO/IEC 11801.ApplicationsData cable for structured premises cabling. For the transmission of digital and analogue voice, video and data signals. Suitable for all ICT network applications up to class D applications (100 MHz) in accordance with EN 50173-1 and ISO/IEC 11801. Applicable for Power over Ethernet (PoE) / PoE+.Fibre OpticsFeaturesCabinets & RacksDimensionSheathSheath Weight n x n x mm (AWG) mm kg/km1811124 x 2 x 0.54 (AWG24)FR/PVC 1)6.145.126.00.150.551000 m drum1811114 x 2 x 0.54 (AWG24)FRNC/LS0H 2)6.145.926.00.130.441000 m drum1)FR/PVC = Flame Retardant / Polyvinyl Chloride2)FRNC/LS0H = Flame Retardant Non Corrosive / Low Smoke Zero Halogen56CU 5502 4P 0312/eGeneral InformationMultimediaWirelessArticle No. Data CentreVersionsSubject to technical modification.Cu weightFire loadPU kg/km kWh/m MJ/m 58. Copper data cables, shieldedData cable SF/UTP Cat.5e AWG24 CU 5502 4PElectrical Characteristics 5eCategory 1410100250Attenuation [dB/100m]1.93.65.618.229NEXT [dB]7570654440PS NEXT [dB]7267624137ACR-N [dB]7366592611PS-ACR-N [dB]706356238ACR-F [dB]8469634131PS-ACR-F [dB]8166603828Return loss [dB]2731312824[dB] 1401 NEXT 55021202 NEXT EN 50288-2-1100 803 Attenuation EN 50288-2-16012030 1 [MHz]Mechanical CharacteristicsGeneral Characteristics101001'00010'000 Bending radius (flat side) during draw-in: 48 mm permanently installed: 24 mm Tensile strength: 91 N Crush resistance: 1000 N/10 cm Impact: 10 impacts Temperature range during installation: 0 C to + 50 C in operation: -20 C to + 60 C Wire colour code white - blue/blue white - orange/orange white - green/green white - brown/brown (ring marked) in accordance with IEC 60189 and IEC 60708ImprintDATWYLER cable type additional text batch number meter marks Zero halogen non corrosive gases Flame propagation Flame spread Smoke density Power over Ethernet EMC Cat./ClassIEC 60754-1/-2, EN 50267-2-1/-2-2 (VDE 0482-267-2-1/-2-2) - applies to FRNC/LSOH IEC 60332-1-2, EN 60332-1-2 (VDE 0482-332-1-2) IEC 60332-3-24, EN 60332-3-24 - applies to FRNC/LS0H IEC 61034-1/-2, EN 61034-1/-2 (VDE 0482-1034-1/-2) applies to FRNC/LS0H IEEE 802.3af shielded better than Cat.5e / Class DGeneral InformationCabinets & Racks4Fibre Optics4 Attenuation 55022Data Centre40WirelessLoop resistance at 20 C: 155 /km Mutual capacitance: 43 pF/m Impedance at 100 MHz: 100 5 Transfer impedance at 1/10/30 MHz: 30/60/170 m/m < Near end unbalance attenuation LCL : >40 dB Delay Skew: 8 ns/100 m NVP: 76 %CopperThese performance data are typical measured values.MultimediaFrequency [MHz]Subject to technical modification.57 59. Copper data cables, shieldedData cable F/UTP Cat.5e AWG24 CU 5002 4PPolyester foilOuter sheath FR/PVC grey RAL 7035 FRNC/LS0H orange RAL 2003Screen Alu Polyester foilWire 1.0 mm , PE Foam SkinDrain wire Tinned copper wireInner conductor AWG24 Bare copper wireCopperProduct information Electrically and mechanically high-quality Cat 5e data cable - fulfils the requirements of ISO/IEC 11801, IEC 61156-5, EN 50173-1 and EN 50288-2-1. Excellent shielding effect due to overall screen foils. Compatible with all current connecting hardware in accordance with EN 50173 and ISO/IEC 11801.ApplicationsData cable for structured premises cabling. For the transmission of digital and analogue voice, video and data signals. Suitable for all ICT network applications up to class D applications (100 MHz) in accordance with EN 50173-1 and ISO/IEC 11801. Applicable for Power over Ethernet (PoE) / PoE+.Fibre OpticsFeaturesCabinets & RacksDimensionSheathSheath Weight n x n x mm (AWG) mm kg/km1811144 x 2 x 0.54 (AWG24)FR/PVC 1)6.040.019.50.160.561000 m drum1811134 x 2 x 0.54 (AWG24)FRNC/LS0H 2)6.040.819.50.140.511000 m drum1)FR/PVC = Flame Retardant / Polyvinyl Chloride2)FRNC/LS0H = Flame Retardant Non Corrosive / Low Smoke Zero Halogen58CU 5002 4P 0312/eGeneral InformationMultimediaWirelessArticle No. Data CentreVersionsSubject to technical modification.Cu weightFire loadPU kg/km kWh/m MJ/m 60. Copper data cables, shieldedData cable F/UTP Cat.5e AWG24 CU 5002 4PElectrical Characteristics Category5e 1410100250Attenuation [dB/100m]1.93.65.618.229NEXT [dB]7570654440PS NEXT [dB]7267624137ACR-N [dB]7366592611PS-ACR-N [dB]706356238ACR-F [dB]8469634131PS-ACR-F [dB]8166603828Return loss [dB]2731312824[dB] 1401 NEXT 50021202 NEXT EN 50288-2-1100 803 Attenuation EN 50288-2-16012030 1 [MHz]Mechanical CharacteristicsGeneral Characteristics101001'00010'000 Bending radius (flat side) during draw-in: 48 mm permanently installed: 24 mm Tensile strength: 91 N Crush resistance: 1000 N/10 cm Impact: 10 impacts Temperature range during installation: 0 C to + 50 C in operation: -20 C to + 60 C Wire colour code white - blue/blue white - orange/orange white - green/green white - brown/brown (ring marked) in accordance with IEC 60189 and IEC 60708ImprintDATWYLER cable type additional text batch number meter marks Zero halogen non corrosive gases Flame propagation Smoke density Power over Ethernet EMC Cat./ClassIEC 60754-1/-2, EN 50267-2-1/-2-2 (VDE 0482-267-2-1/-2-2) - applies to FRNC/LS0H IEC 60332-1-2, EN 60332-1-2 (VDE 0482-332-1-2) IEC 61034-1/-2, EN 61034-1/-2 (VDE 0482-1034-1/-2) - applies to FRNC/LS0H IEEE 802.3af shielded better than Cat.5e / Class DGeneral InformationCabinets & Racks4Fibre Optics4 Attenuation 50022Data Centre40WirelessLoop resistance at 20 C: 155 /km Mutual capacitance: 43 pF/m Impedance at 100 MHz: 100 5 Transfer impedance at 1/10/30 MHz: < 45/90/190 m/m Near end unbalance att. LCL : >40 dB Delay Skew: 8 ns/100 m NVP: 76 %CopperThese performance data are typical measured values.MultimediaFrequency [MHz]Subject to technical modification.59 61. Copper data cables, shieldedFlexible data cable S/FTP Cat.7A AWG26 CU 7150 4P flexScreen Tinned braided copperOuter sheath FR/PVC 1) grey RAL 7035 FRNC/LS0H orange RAL 2003 (see table for other colours)Wire 0.99 mm Screen pair Alu PETP foilInner conductor AWG26 Bare copper wire, strandedCopperProduct information Electrically and mechanically excellent Cat.7A patch cord - exceeds the requirements of ISO/IEC 11801, IEC 61156-6, IEC 61156-8, EN 50173-1, EN 50288-4-2 and prEN 50288-9-2. Excellent shielding effect due to individually screened pairs and overall copper braid. Easy wire identification and termination due to different coloured wires. Compatible with all current connecting hardware in accordance with EN 50173 and ISO/IEC 11801. Optimised for RJ45 connecting systems. Differently coloured sheaths facilitate clearly arranged installations and visual differentiation of services.ApplicationsFibre OpticsFeaturesAs patch cord in patch panels and as equipment connection cable. For the tr