data.powerflame.com support supportdocs websitefiles pdf c-manual
TRANSCRIPT
8/11/2019 Data.powerflame.com Support Supportdocs WebsiteFiles PDF C-manual
http://slidepdf.com/reader/full/datapowerflamecom-support-supportdocs-websitefiles-pdf-c-manual 1/1
MANUAL C888 Rev. 0214
1. General Product Information 1 Principal of Operation2 Model Identification
2 Unpacking and Handling2 Warranty and Spare Parts
3 General Component Information3 Burner Component Identification
On-Off Fuel/Air Control Modes4 Burner Component Identification
Low-High-Off or Low-High-LowFuel/Air Control Modes
4 Burner Component IdentificationModulating Fuel/Air Control Modes
5 Standard Burner DimensionalData
6 Standard Burner Ratings andComponent Data
7 Control Panel Information
2. Installation 9 Gas Supply Piping - General9 Gas Supply Line Sizing Charts10 Gas Train Components Supplied
for Standard UL BurnerRequirements
10 Gas Train Piping Schematicsfor Standard UL Burner
Requirements11 Oil Supply Piping - General11 Oil Pump Suction Capacity and
Filter Selection Information
12 Oil Line Sizing Charts
12 Oil Pump Detail
13 Multiple Burner System OilPiping Schematic
13 Combustion Air Requirements
13 Burner Mounting - General
Principal of Operation Power Flame Type C Burners incorporate the principlesof pressure atomization for oil and multiple orifice, venturioperation for gas. The total package utilizes the forceddraft, flame retention concept. The Type C burner is listedand labeled by Underwriters Laboratories, Inc. Capaci-
ties, when fired at 0.2” w.c. positive combustion chamberpressure, range from 3 to 136.4 GPH of commercial grade#2 fuel oil and/or 98 to 19,100 CFH of natural gas. Air forcombustion is furnished by an integrally mounted com-bustion air fan. The Power Flame packaged combustionsystem can be operated under positive or negative furnacepressures with clean, efficient combustion in a wide rangeof combustion chamber conditions. (Consult page 6 forappropriate ratings.)
The Power Flame C Burner is a totally packaged andtory tested combustion system offering single unit resibility. The package incorporates accurate control ofuel-air ratio throughout the firing range with the resucontrolled flame patterns and clean combustion for
mum efficiency.
Power Flame Type C Burners are designed to produce greaterflame turbulence and reduce flame size. As aresult, they require less combustion volume for completecombustion and can be easily fired under positive furnacepressure. Forced draft pressurized operation requiresstacks of smaller diameter and height.
Combustion air flow is controlled by a multi-louvereddamper assembly. The combustion air is supplied ban integral motor-driven blower, which discharges inthe burner blast tube assembly. High turbulence flowcontrolled by means of an adjustable fan diffuser sysVarious system mode operations are obtained by aping appropriate control valves and fuel/air actuators. are capable of operating in modes consistent with spdemand requirements, from fixed or on-off through fu
modulation.
The air/fuel ratio is established at the time of start-upproven with combustion test equipment to provide thlowest practical oxygen with a clean flame.
13 Combustion Chamber - General
14 Combustion Chamber Data
3. Mechanical Operation of
Fuel/Air Control Modes
15 Gas - On-Off
15 Gas - Low-High-Off and Low-High-Low16 Gas - Full Modulation
16 Oil - On-Off
17 Oil - Fixed Air Low Fire Start
18 Reduced Air Low Fire Start System
19 Oil - Low-High-Off and Low-High-
Low with Webster Oil Pump
20 Oil - Low-High-Off and Low-High-
Low with Suntec 2-Step Oil Pump
21 Oil - Full Modulation
22 Diffuser Position Adjustment for Gas,
Oil or Gas/Oil Burners
22 Gas or Gas/Oil Burner Fuel/Air
Premix Adjustment22 Gas/Oil - Linkage Arrangement for
Full Modulation - Standard System
22 Gas/Oil - Detail and Adjustments on
Modulating VaricamTM Characterized
Fuel Metering System
4. Start Up, All Fuel
23 All Fuels - General Start Up Procedures
23 Information on Fuel/Air Modes of
Operation for Combination Gas/Oil
Units
24 Burner Start Up and Service Test
Equipment Required
5. Gas Start Up 25 General Gas Start Up Procedure
6. Oil Start Up
28 General Oil Start Up Procedure
7. Servicing and Comp
Adjustments
31 General Information on In
By-pass Oil Nozzle System
31 Internal Bypass Nozzle Da
34 Oil Nozzle Flow Rates34 Oil Nozzle Servicing
34 Oil Pump or Oil Flow Prob
35 Direct Spark Oil Ignition
Adjustments
35 Oil Drawer Assembly Diag
36 Gas/Oil Burner Firing Hea
Cutaway
36 Gas and Gas/Oil Gun Ass
Diagrams
37 Gas Burner Orifice Sizing
38 Limiting Orifice Informatio
39 Gas Pilot Ignition Adjustm
39 Pilot Spark Ignition Electr Adjustment
40 Gas Pilot Flood Test
41 Flame Safeguard Control
Signal Values
41 CO2-O2 Ratio Curves for F
Oils and Gases
42 Trouble Shooting Sugges
8. Maintenance
44 General
45 Periodic Check List
9. Burner Start Up Info
and Test Data
46 Combustion Analysis47 Control Settings
51 10. Gas and Oil Burner O
Operating Instructio
CONTENTS
1. GENERAL PRODUCT INFORMATION