HYDROCOIL™ DATA SHEET Stator Coils designed to increase hydro generator reliability Stator Coils designed to increase hydro generator reliability Patented IPS technology Available up to 15 kV & 50 MW Exceeds IEEE 1553-2002 Voltage Endurance for Hydro Generators Exceeds IEEE 1147-2005 Rehabilitation of Hydro Plants Industry-leading coil Mica density (g/cm3) Industry-leading coil dielectrics (V/mil) Engineering – Generator uprates & stator coil design Experienced on-site rewind technicians Completed rewind of Westinghouse 45 MW, 11.5 kV, 400 RPM hydro generator Magnified coil cross section shows uniformly compressed tapes absent of puckers and voids. Uniformly compressed tapes prevent coil imperfections and partial discharge. Best-in-class hydro generator rewinds HydroCoil is our premium, B-stage, resin-rich stator coil offering for hydro generator rewinds up to up to 15 kV and 50 MW. It was developed by hydro utility and IPS engineers to maximize stator winding reliability and exceed IEEE 1553-2002 and IEEE 1147-2005 hydro industry testing and rehabilitation standards. Reliability. Delivered. NORTH AMERICAN COVERAGE CANADA Regina, SK 306-586-0000 Saskatoon, SK 306-651-0400 Winnipeg, MB 204-237-6066 UNITED STATES Beaumont, TX 888-868-9475 Birmingham, AL 800-978-2212 Chicago, IL 800-978-4559 Cincinnati, OH 800-998-8447 Cleveland, OH Corpus Christi, TX 800-433-7801 361-459-2600 Denver, CO 800-448-0899 Detroit, MI 800-992-9466 Dothan, AL 334-699-8080 Erie, PA Evansville, IN 724-479-9066 800-998-8447 Folcroft, PA 484-498-4848 Houston, TX 800-221-3698 Indiana, PA 800-537-0097 Lake Benton, MN 507-368-4015 Litchfield, MN 888-694-6200 Philadelphia, PA 800-451-5718 Portland, OR 800-366-4951 Rock Hill, SC 800-868-3702 Rock Springs, WY 866-256-4798 Shreveport, LA 800-366-6030 Sulphur, LA 409-833-9477 Washington, PA 800-441-2553 www.ips.us www.ips.ca The HydroCoil is custom engineered and employs advanced resin-rich tapes and processing methods for enhanced thermal cycling and improved dielectrics. The processing methods are optimized to increase ground wall density and ensure complete resin migration. The design and engineering combine to create a void-free coil, preventing delamination and any microvoids that can result in partial discharge activity and subsequent insulation deterioration. These fully cured and homogenized coils also prevent shrinkage, which means no re-wedging is required. The HydroCoil’s improved dielectrics and thermal dissipation means hydro generator rewinds can typically offer an increase in generator rating, permitting higher output power generation levels.

Upload: others

Post on 09-Mar-2021

4 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: DATA SHEET HYDROCOIL™ · 2017. 4. 27. · • IEEE 1434 Partial Discharge • IEEE 522 Surge Test to 40 kV HYDROCOIL STATOR COILS ©2017 Integrated Power Services 4/17 UNITED STATES

HYDROCOIL™DATA SHEET

Stator Coils designed to increase hydro generator reliabilityStator Coils designed to increase hydro generator reliability

• Patented IPS technology

• Available up to 15 kV & 50 MW

• Exceeds IEEE 1553-2002 Voltage Endurance for Hydro Generators

• Exceeds IEEE 1147-2005 Rehabilitation of Hydro Plants

• Industry-leading coil Mica density (g/cm3)

• Industry-leading coil dielectrics (V/mil)

• Engineering – Generator uprates & stator coil design

• Experienced on-site rewind technicians

Completed rewind of Westinghouse 45 MW, 11.5 kV, 400 RPM hydro generator

Magnified coil cross section shows uniformly compressed tapes absent of puckers and voids. Uniformly compressed tapes prevent coil imperfections and partial discharge.

Best-in-class hydro generator rewindsHydroCoil is our premium, B-stage, resin-rich stator coil offering for hydro generator rewinds up to up to 15 kV and 50 MW. It was developed by hydro utility and IPS engineers to maximize stator winding reliability and exceed IEEE 1553-2002 and IEEE 1147-2005 hydro industry testing and rehabilitation standards.

Reliability. Delivered.

NORTH AMERICAN COVERAGE

CANADA

Regina, SK 306-586-0000

Saskatoon, SK 306-651-0400

Winnipeg, MB 204-237-6066

UNITED STATES

Beaumont, TX 888-868-9475

Birmingham, AL 800-978-2212

Chicago, IL 800-978-4559

Cincinnati, OH 800-998-8447

Cleveland, OH

Corpus Christi, TX

800-433-7801

361-459-2600

Denver, CO 800-448-0899

Detroit, MI 800-992-9466

Dothan, AL 334-699-8080

Erie, PA

Evansville, IN

724-479-9066

800-998-8447

Folcroft, PA 484-498-4848

Houston, TX 800-221-3698

Indiana, PA 800-537-0097

Lake Benton, MN 507-368-4015

Litchfield, MN 888-694-6200

Philadelphia, PA 800-451-5718

Portland, OR 800-366-4951

Rock Hill, SC 800-868-3702

Rock Springs, WY 866-256-4798

Shreveport, LA 800-366-6030

Sulphur, LA 409-833-9477

Washington, PA 800-441-2553

www.ips.us

www.ips.ca

The HydroCoil is custom engineered and employs advanced resin-rich tapes and processing methods for enhanced thermal cycling and improved dielectrics. The processing methods are optimized to increase ground wall density and ensure complete resin migration. The design and engineering combine to create a void-free coil, preventing delamination and any microvoids that can result in partial discharge activity and subsequent insulation deterioration. These fully cured and homogenized coils also prevent shrinkage, which means no re-wedging is required. The HydroCoil’s improved dielectrics and thermal dissipation means hydro generator rewinds can typically offer an increase in generator rating, permitting higher output power generation levels.

Page 2: DATA SHEET HYDROCOIL™ · 2017. 4. 27. · • IEEE 1434 Partial Discharge • IEEE 522 Surge Test to 40 kV HYDROCOIL STATOR COILS ©2017 Integrated Power Services 4/17 UNITED STATES

IEEE 1310 Thermal Cycling life test

IEEE 1043 Voltage Endurance life test

Industry-Leading Qualification TestingDuring testing for thermal cycling and thermal aging, the HydroCoil exhibited superior mechanical properties and thermal dissipation characteristics. The coils also exceeded all industry standards for voltage endurance testing. An independent 3rd party was used for verification testing, and the HydroCoil successfully completed the following tests:

• IEEE 1310 Thermal Cycling

» 500 Cycles X 90 minutes, 40˚C - 155˚C

• IEEE 1043 Voltage Endurance

» 400 Hours @ 30 kV

» 250 Hours @ 35 kV

• IEEE 1776-2008 Water Immersion at 15 kV

• IEEE 95 Hi Pot Test to 70 kV

• IEEE 286 Power Factor Tip Up

• IEEE 1434 Partial Discharge

• IEEE 522 Surge Test to 40 kV

HYDROCOIL STATOR COILS

©2017 Integrated Power Services 4/17

UNITED STATESBeaumont, TX

Birmingham, ALChicago, IL

Cincinnati, OHCleveland, OH

Corpus Christi, TXDenver, CODetroit, MIDothan, AL

Erie, PAEvansville, INFolcroft, PA

Greenville, SCHouston, TXIndiana, PA

Lake Benton, MNLitchfield, MN

Philadelphia, PAPortland, ORRock Hill, SC

Rock Springs, WYShreveport, LA

Sulphur, LAWashington, PA

CANADARegina, SK

Saskatoon, SKWinnipeg, MB

www.ips.uswww.ips.ca

NORTH AMERICAN COVERAGE

Copper Strand

Strand Insulation

Mica Turn Tape

Resin Rich Mica Ground Wall Tape

Conductive Tape

Stress Grading Tape

Armor Tape

CROSS SECTION

HYDRO GENERATOR COILS

TM