  • 8/4/2019 Daniel Brandao - Digital Metering 2

    1/12

    IEC 61850 for the PowerLogic ION7550/ION7650Power and energy meter

    Daniel BrandaoPLUG Conference

    Edmonton

    Nov 5, 2010

  • 8/4/2019 Daniel Brandao - Digital Metering 2

    2/12

    Schneider Electric 2- Division - Name Date

    Introduction

    A major part of Schneider Electric strategy to differentiate its

    products is

    based on providing the most comprehensive set of communication options:

    Multiple communication ports:

    RS-232; RS-485; InfraRed

    optical

    port, Modem, Ethernet (100BaseTX

    and 100BaseFX)

    Multiple protocols:

    ION; Modbus

    RTU (slave / master);

    Modbus

    TCP; DNP 3.0, Ethergate,

    Modemgate

    and now IEC 61850

  • 8/4/2019 Daniel Brandao - Digital Metering 2

    3/12

    Schneider Electric 3- Division - Name Date

    Where does IEC 61850 come from?

    Substation situation

    What are these challenges?

    Lack of interoperability between devices high integration costs;

    Limited vendor choice not always the best product for a particular need;

    Multiple technologies working together high maintenance costs;

  • 8/4/2019 Daniel Brandao - Digital Metering 2

    4/12Schneider Electric 4- Division - Name Date

    Why IEC 61850 is different

    IEC 61850 protocol was created to take advantage of modern Ethernet switched

    technology and, in addition to the specification of the protocol

    elements (how

    bytes are transmitted on the wire), IEC 61850 provides a comprehensive

    model for how power system devices should organize data in a manner thatis consistent across all types and brands of devices:

    IEC 61850 protocol was created to take advantage ofmodern Ethernet switched

    technology

    and, in addition to the specification of the protocol elements (how

    bytes are transmitted on the wire), IEC 61850 provides a comprehensive

    model forhow power system devices should organize data in a manner thatis consistent across all types and brands of devices:

    Object model based on human understandable names: V Phase A

    is 26.3 kV

    instead of IED1, Obj

    30, Var

    4, #6 = Va;

    Standardized data grouping based on function, rather than on

    device type;

    Self describing devices vendor provides a file with the devicesfeatures;

    Standardized configuration language (SCL): precise definition of

    a

    devices role in a power system

  • 8/4/2019 Daniel Brandao - Digital Metering 2

    5/12Schneider Electric 5- Division - Name Date

    Why IEC61850 is different

  • 8/4/2019 Daniel Brandao - Digital Metering 2

    6/12Schneider Electric 6- Division - Name Date

    IEC 61850

    Customer Benefits

  • 8/4/2019 Daniel Brandao - Digital Metering 2

    7/12

    Schneider Electric 7- Division - Name Date

    Both ION 7550 and ION 7650 will support IEC 61850 protocol. The meters willprovide via 61850:

    Operational metering data (V, I, PF, Power, Energy totals) and some powerquality parameters (harmonics, symmetrical components);

    Access to read and write meter digital & analog I/O;

    Custom mapping of ION values into 61850 in addition to standard models;

    Up to 4 client connections

    Reporting service for 61850 data: 1 buffered and 5 unbuffered

    reports per client,

    50 members max;

    Additional features: COMTRADE waveform recording and time synchronization via

    SNTO

    IEC 61850 Implementation on ION meters

  • 8/4/2019 Daniel Brandao - Digital Metering 2

    8/12

    Schneider Electric 8- Division - Name Date

    IEC 61850 Configuration flow:

    IEC 61850 Implementation on ION meters

  • 8/4/2019 Daniel Brandao - Digital Metering 2

    9/12

    Schneider Electric 9- Division - Name Date

    The ICD files can be downloaded from www.powerlogic.com

    IEC 61850

    Implementation on ION meters

  • 8/4/2019 Daniel Brandao - Digital Metering 2

    10/12

    Schneider Electric 10- Division - Name Date

    ION modules:

    Within the devices native ION architecture, specific ION modules map data to

    each of the IEC 61850 logical nodes:

    IEC 61850 Implementation on ION meters

  • 8/4/2019 Daniel Brandao - Digital Metering 2

    11/12

    Schneider Electric 11- Division - Name Date

    Summary:

    High accuracy (0.2S) and Power Quality metering data are now available through

    IEC 61850 protocol ION 7550 and ION 7650 PQ meters

    This new feature will be available in the next firmware release (V360) and installed

    meters can be upgraded on the field;

    COMTRADE waveform formats are now available directly from the meter;

    An FTP server is now available on the meter for transfer of IEC 61850 configuration

    files and COMTRADE records;

    IEC 61850 implementation on ION 7550 and 7650 meters are certified by Kema;

    IEC 61850 Implementation on ION meters

  • 8/4/2019 Daniel Brandao - Digital Metering 2

    12/12

    Schneider Electric 12- Division - Name Date

    Questions?

    Daniel Brandao NetoPower Monitoring Offer Manager PQ [email protected]