curries tech data frame section.pdf5 masonry face flush kd frame cased opening frame technical data...

141
CURRIES Tech Data Frame Section Revised June, 2020

Upload: others

Post on 18-Jul-2020

2 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: CURRIES Tech Data Frame Section.pdf5 Masonry Face Flush KD Frame Cased Opening Frame Technical Data March, 2015 VARIES 3” (76.2) MINIMUM 1” (25.4) 1-1/4” (31.8) 1-1/2” (30.1)

CURRIES Tech DataFrame Section

Revised June, 2020

Page 2: CURRIES Tech Data Frame Section.pdf5 Masonry Face Flush KD Frame Cased Opening Frame Technical Data March, 2015 VARIES 3” (76.2) MINIMUM 1” (25.4) 1-1/4” (31.8) 1-1/2” (30.1)

iIndex

Frame Technical DataAugust, 2017

DESCRIPTION PAGE(S)

Anchors – Drywall FrameBase Anchor ...........................................................................................................................35Compression Anchor .........................................................................................................34, 36, 39Multipurpose Anchor Installation .............................................................................................17Steel Channel Anchor Installation ...........................................................................................126Security Anchor ......................................................................................................................34

Anchors – Flush Frame (Masonry)Ceiling Strut ............................................................................................................................18Conduit Compatible .............................................................................................................75-76Electric Steel Channel .............................................................................................................14Existing Wall Anchors.........................................................................................................9, 11, 12Floor Anchor (Foot Clip) ..........................................................................................................6-7Loose Spline ..........................................................................................................................128Masonry Anchors ..................................................................................................................9-10Mullion Stirrup Anchor ............................................................................................................18Multipurpose Anchor ...............................................................................................................16Steel Channel Anchor...........................................................................................................13-14Steel Channel Anchor Installation ...........................................................................................126Wire Truss Anchor ..................................................................................................................15Wood Stud Anchor ..................................................................................................................15

Borrowed Lite Frames ...............................................................................................................41-42Cabinet Jamb Frames ..................................................................................................................90CCW Stick Length Components ...............................................................................................109-120Communicating Frames/Mullion ...................................................................................................96Curriseal Frames ......................................................................................................................92-93Custom Frame Profiles ............................................................................................................121-122Double Egress Frames ..............................................................................................................2, 107Drywall Frames

Corner Detail .......................................................................................................................32-33 Installation ..............................................................................................................................40 Profiles ................................................................................................................................36-38

Throat Filler ............................................................................................................................43KD Frame Assembly Instructions .............................................................................................129-131ElectroLynx System ....................................................................................................................138Fabricaton Frame Corner Details

Cutting and Notching ...........................................................................................................27-31Field Splice .............................................................................................................................24Welded Corner Details .........................................................................................................19-23

Flush Masonry Frames Corner Details ........................................................................................................................1-3 Profiles ..................................................................................................................................3-5

Page numbers are linked

Page 3: CURRIES Tech Data Frame Section.pdf5 Masonry Face Flush KD Frame Cased Opening Frame Technical Data March, 2015 VARIES 3” (76.2) MINIMUM 1” (25.4) 1-1/4” (31.8) 1-1/2” (30.1)

iiIndexFrame Technical Data

October, 2018

DESCRIPTION PAGE(S)

Grout Hole ...................................................................................................................................85 Hardware Locations .............................................................................................................................44-48 Preparations Automatic Flush Bolts ......................................................................................................87 Closer Preparations .......................................................................................................77-81 Coordinator Preparations ..................................................................................................84 Deadlock Strike Preparations ...........................................................................................67 Electric Strike Preparations ........................................................................................74, 88, 89 Lock .............................................................................................................................68-71 Exit Device Preparations Rim Exit ...........................................................................................................................73 Vertical Rod Exit ...............................................................................................................72 Flush Bolt Preparations ........................................................................................................86-87 Hinge Preparations 4-1/2” .............................................................................................................................50 5” ....................................................................................................................................51 Anchor Hinge Preparation.................................................................................................58 Continuous Hinge Preparation ..........................................................................................55 Electric Hinges ..............................................................................................................52, 57 Double Acting Hinges .......................................................................................................59 Full width Hinge Reinforcement ........................................................................................54 High Frequency Hinge Reinforcement ...............................................................................53 Pocket Pivot Preparation ..................................................................................................60 Security Hinge .................................................................................................................56 Mullion (Hardware Removable) ...............................................................................................83 Pivots ..................................................................................................................................63, 64 Strikes ...........................................................................................................................61, 65, 66, 70 Surface Bolt Preparation .........................................................................................................83 Hospital Stops .............................................................................................................................100 KD Frame Assembly Instructions .............................................................................................129-131 KD SideLight Frame ....................................................................................................................137 Lead Lined Frame Steel Channel ..................................................................................................19 Mullion Construction ..........................................................................................................................103 Removable Mullion Vertical / Horzontal ..............................................................................104-105 Pocket Door Frame ...................................................................................................................97-98 Rabbet Dimensions ......................................................................................................................49 Rescue Hardware ........................................................................................................................62 Rough Buck Frames.....................................................................................................................91 Security Sidelite Frames .............................................................................................................133 Silencers ....................................................................................................................................127 Slip-on Drywall Frames ...............................................................................................................135 Slip-on Hybrid Drywall Frames ....................................................................................................136 Spats ........................................................................................................................................99 Stainless Steel Frames .............................................................................................................25, 26 Mercury Thermal Break Frame................................................................................................123, 124 Mercury Thermal Break Frame with Stucco Flange .....................................................................125 Thermal Break Frames ...........................................................................................................101-102 Transom Frame Removable Panel Installation .............................................................................134 Wall construction Details Masonry ..................................................................................................................................8

Page 4: CURRIES Tech Data Frame Section.pdf5 Masonry Face Flush KD Frame Cased Opening Frame Technical Data March, 2015 VARIES 3” (76.2) MINIMUM 1” (25.4) 1-1/4” (31.8) 1-1/2” (30.1)

1Flush Masonry KD Miter Corner Joint

Frame Technical DataMarch, 2015

L#8 SCREW (MS002485)(REQUIRED ON ALL FIRERATED KD FRAMES)

HEAD

JAMB

SPOT WELDS

BREAK –OFF TOOL

JAMB

JAMB

BEND TABS TOWARD WALL

HEAD

CORNER ASSEMBLY2” (50.8) HEAD

BREAK AWAYCORNER CLIP

2-7/16”(61.9)

1-13/16”(46)

USING THE BREAK-OFF TOOL, BENDCLIP BACK AND FORTH TOWARD OPPOSITE FACE OF FRAME.DO NOT BEND PAST THE OUTSIDE FACE TO AVOID DEFORMING THE FACE.

NOTE: USING PLIERS TO BREAK OFF THE CORNER CLIP MAY RESULT IN DAMAGE TO THE FACE OF FRAME

Page 5: CURRIES Tech Data Frame Section.pdf5 Masonry Face Flush KD Frame Cased Opening Frame Technical Data March, 2015 VARIES 3” (76.2) MINIMUM 1” (25.4) 1-1/4” (31.8) 1-1/2” (30.1)

2Masonry KD 4” Face HeadFrame Technical Data

March, 2015

L

Masonry KD Double Egress Frame

L

#8 SCREW(REQUIRED ON ALL FIRERATED KD FRAMES)

HEAD FILLERCORNER CLIP

BEND TABS TOWARD WALL

#8 SCREW(REQUIRED ON ALL FIRERATED KD FRAMES)

BEND TABSTOWARD WALL

* 5-3/4” (146.1) JAMB DEPTH HAS 7/16” (11.1) RETURN

4-3/4” - 14”(120.6) - (355.6)

1/2”*(12.7)

2-5/8”(66.7)

1-3/8”(34.9)

JAMBDEM

HEADGE 2-5/8”

(66.7)

4-3/4” - 14”(120.6) - (355.6)1/2”*

(12.7)

2”(50.8)

Page 6: CURRIES Tech Data Frame Section.pdf5 Masonry Face Flush KD Frame Cased Opening Frame Technical Data March, 2015 VARIES 3” (76.2) MINIMUM 1” (25.4) 1-1/4” (31.8) 1-1/2” (30.1)

3Masonry KD “G” Profile - Corner Details

Frame Technical DataMarch, 2015

L

JAMBHEAD

CORNER ASSEMBLY

BEND TABSTOWARD WALL

Masonry KD 2” Face Flush Frame Unequal Rabbet

L1-15/16”(49.2)

VARIES 1-9/16”(39.7)

5/8”(15.9)

2”(50.8)

1/2”(12.7)

M

KD “M” TYPE FLUSHGAUGE - 18 GA. (1.2), 16 GA. (1.4), 14 GA. (1.9)VARIABLE SOFFITJAMB DEPTH 4-1/2” (114.3) THRU 14” (355.6) (1/8”(3.2) INCREMENTS)AVAILABLE WITH 4” (101.6) FACE HEADSNOTE: 5-3/4” (146.1) JAMB DEPTH STANDARD WITH 7/16” (11.1) RETURNSTO PROVIDE 4-7/8” (123.8) THROAT OPENING

#8 SCREW(REQUIRED ON ALL FIRERATED KD FRAMES)

Optional face dimension:1" through 2" in 1/8" increments

Optional return dimension:7/16" through 1"

Rabbets can vary 5/8" through 6" on non door rabbet.

Page 7: CURRIES Tech Data Frame Section.pdf5 Masonry Face Flush KD Frame Cased Opening Frame Technical Data March, 2015 VARIES 3” (76.2) MINIMUM 1” (25.4) 1-1/4” (31.8) 1-1/2” (30.1)

4Masonry 1”, 1-1/4”, 1-1/2”, 1-3/4”, Face Flush KD Frame Unequal RabbetFrame Technical DataMarch, 2015

L 1-15/16”(49.2)

VARIES 1-9/16”(39.7)

5/8”(15.9)

1” (25.4), 1-1/4” (31.8)1-1/2” (38.1), 1-3/4” (44.5)

1/2”(12.7)

KD “M” TYPE FLUSHGAUGE - 18 GA. (1.2), 16 GA. (1.4), 14 GA. (1.9)VARIABLE SOFFITJAMB DEPTH 4-1/2” (114.3) THRU 14” (355.6) (1/8”(3.2) INCREMENTS)NOT AVAILABLE WITH 4” (101.6) FACE HEADSNOTE: WHEN CCW MATERIAL IS USED IN CONJUNCTION WITH ABOVE, COORDINATE RABBET AND FACE DIMENSIONS 5-3/4” (146.1) JAMB DEPTH STANDARD WITH 7/16” (11.1) RETURNS TO PROVIDE 4-7/8” (123.8) THROAT OPENING.

M

Masonry Flush KD Frame Equal Rabbet

L VARIES

5/8”(15.9)

1” (25.4), 1-1/4” (31.8)1-1/2” (38.1), 1-3/4” (44.5)

2” (50.8)

1/2”(12.7)

M

1-15/16” (49.2)OR

1-9/16” (39.7)

1-15/16” (49.2)OR

1-9/16” (39.7)

KD “M” TYPE FLUSHGAUGE - 18 GA. (1.2), 16 GA. (1.4), 14 GA. (1.9) VARIABLE SOFFITJAMB DEPTH 4-7/8” (114.3) THRU 14” (355.6) (1/8”(3.2) INCREMENTS)AVAILABLE WITH 4” (101.6) FACE HEADS WITH 2” FACE JAMBS ONLYNOTE: WHEN CCW MATERIAL IS USED IN CONJUNCTION WITH ABOVE, COORDINATE RABBET AND FACE DIMENSIONS. 5-3/4” (146.1) JAMB DEPTH STANDARD WITH 7/16” (11.1) RETURNS TO PROVIDE 4-7/8” (123.8) THROAT OPENING.

Optional face dimension:1" through 2" in 1/8" increments

Optional return dimension:7/16" through 1"

Rabbets can vary 5/8" through 6" on non door rabbet.

Optional face dimension:1" through 2" in 1/8" increments

Optional return dimension:7/16" through 1"

Rabbets can vary 5/8" through 6" on non door rabbet.

Page 8: CURRIES Tech Data Frame Section.pdf5 Masonry Face Flush KD Frame Cased Opening Frame Technical Data March, 2015 VARIES 3” (76.2) MINIMUM 1” (25.4) 1-1/4” (31.8) 1-1/2” (30.1)

5Masonry Face Flush KD Frame Cased Opening

Frame Technical DataMarch, 2015

VARIES3” (76.2) MINIMUM

1” (25.4)1-1/4” (31.8)1-1/2” (30.1)1-3/4” (44.5)

2” (50.8)

1/2”(12.7)

MK

KD “MK” TYPE FLUSHGAUGE - 18 GA. (1.2), 16 GA. (1.4), 14 GA. (1.9)JAMB DEPTH 3” (76.2) THRU 14” (355.6) (1/8” (3.2) INCREMENTS)NOTE: AVAILABLE WITH 4” (101.6) FACE HEAD WITH 4-1/2” (114.3) MINIMUM JAMB DEPTH 5-3/4” (146.1) JAMB DEPTH STANDARD WITH 7/16” (11.1) RETURNSTO PROVIDE 4-7/8” (123.8) THROAT OPENING.

Masonry Flush KD “G” Profile Frame

L

G

VARIES

2”(50.8)

1/2”(12.7)

1-15/16” (49.2)OR

1-9/16” (39.7)

5/8”(15.9)

2-5/8”(66.7)

KD “G” TYPE FLUSHGAUGE - 18 GA. (1.2), 16 GA. (1.4), 14 GA. (1.9)JAMB DEPTH 3” (76.2) THRU 14” (355.6) (1/8” (3.2) INCREMENTS)MIN. 4” JAMB DEPTH FOR LABELED FRAME WITH 1-15/16” RABBET AND 3-1/4” JAMB DEPTH FOR 1-9/16” RABBET.NOTE: 2” (50.8) AND 2-5/8” (66.7) FACE ON JAMBSAVAILABLE WITH 4” (101.6) FACE HEAD WITH 4-1/2” (114.3) MINIMUM JAMB DEPTH. 5-3/4” (146.1) JAMB DEPTH STANDARD WITH 7/16” (11.1) RETURNSTO PROVIDE 4-7/8” (123.8) THROAT OPENING.

L *

* TOTAL DOOR ONLY MAY BE LABELED

Optional face dimension:1" through 2" in 1/8" increments

Optional return dimension:7/16" through 1"

Rabbets can vary 5/8" through 6" on non door rabbet.

Optional face dimension:1" through 2" in 1/8" increments

Optional return dimension:7/16" through 1"

Page 9: CURRIES Tech Data Frame Section.pdf5 Masonry Face Flush KD Frame Cased Opening Frame Technical Data March, 2015 VARIES 3” (76.2) MINIMUM 1” (25.4) 1-1/4” (31.8) 1-1/2” (30.1)

6Standard Foot ClipsFrame Technical Data

April, 2002

L

2” (50.8)STANDARD

2” (50.8)

FACE MINUS 3/8” (9.5)LABEL REQUIREMENTS: FACE MINUS 1/2” (12.7) MAXIMUM

9/32” (7.1) DIA.

P0030STANDARD FOOT CLIP16 GA. (1.4)

P0081DOUBLE EGRESSFOOT CLIPS

P0030C TYPE FRAME

FACE MINUS 3/8” (9.5)LABEL REQUIREMENTS: FACE MINUS 1/2” (12.7) MAXIMUM

P0080G PROFILEJAMB DEPTH 4” (101.6) OR LESS

P0081G PROFILEGREATER THAN 4” (101.6) JAMB DEPTH

P0216 - 16 GA.FOR FACE WIDTH OVER 4”P0281 - 14 GA.P0284 - 12 GA.

Page 10: CURRIES Tech Data Frame Section.pdf5 Masonry Face Flush KD Frame Cased Opening Frame Technical Data March, 2015 VARIES 3” (76.2) MINIMUM 1” (25.4) 1-1/4” (31.8) 1-1/2” (30.1)

7Adjustable Foot Clip

Frame Technical DataApril, 2002

L

Adjustable Foot Clip - Cased Opening

L

FOOT CLIP SHIPPED LOOSE WITH 2-#12 SHEET METAL SCREWS

ANCHOR PART NUMBER: P0078

5/8” (15.7)3/4” (19.1)

16 GA. (1.4)

1/2” (12.7)

3-5/8” (92)

1/4” (6.4)4-5/8”

(117.5)

PER FACE DIMENSION16 GA. (1.4)

PER JAMB DEPTH

9/32” (7.1) DIA.

5/8” (15.7)3/4” (19.1)

16 GA. (1.4)

1/2” (12.7)

3-5/8” (92)

1/4” (6.4)4-5/8”

(117.5)

PER FACE DIMENSION16 GA. (1.4)

PER JAMB DEPTH

9/32” (7.1) DIA.

FOOT CLIP SHIPPED LOOSE WITH 2-#12 SHEET METAL SCREWS

ANCHOR PART NUMBER: P0151

Page 11: CURRIES Tech Data Frame Section.pdf5 Masonry Face Flush KD Frame Cased Opening Frame Technical Data March, 2015 VARIES 3” (76.2) MINIMUM 1” (25.4) 1-1/4” (31.8) 1-1/2” (30.1)

8Common Walls For Masonry AnchorFrame Technical Data

April, 2002

L

BUTTED MASONRY-BRICK-TILE OR CMU

GROUT FULL

SHIM AS REQUIRED

GROUT OPTIONAL

EXISTING MASONRY OR POURED CONCRETE.

WRAP MASONRY-BRICK-TILE OR CMU

BUTTED MASONRY-BRICK-TILE OR CMU

BUTTED MASONRY-BRICK-TILE OR CMU

Page 12: CURRIES Tech Data Frame Section.pdf5 Masonry Face Flush KD Frame Cased Opening Frame Technical Data March, 2015 VARIES 3” (76.2) MINIMUM 1” (25.4) 1-1/4” (31.8) 1-1/2” (30.1)

9Masonry Wire Anchor

Frame Technical DataApril, 2002

L

Concealed Existing Opening Anchor

L

ANCHOR PART NUMBER: P0098ORDER CODE LOOSE: MW

WIRE DIA. 3/16” (4.8) GALV.ANCHOR MAY BE BENTTO SUIT JAMB DEPTH

9” (228.6)

5-5/8” (142.9)

1-7/8” (47.6)

1-1/16” (27)

COUNTERSINK HOLE FOR 3/8” (9.5) F.H. BOLT

9/16” (14.3) DIA.

ANCHOR PART NUMBER: CF004557100 ANCHORS W/PLASTIC PLUG

PLASTIC PLUG PART NUMBER: MS002600100 PLASTIC PLUGS

PLASTIC PLUG

3/4” (19.1) HOLE INCENTER OF SOFFIT

NOT DRILLED BY CURRIES

3/8” (9.5) BOLT & EXPANSION SHELL(NOT PROVIDED)

NOTE: ANCHORS AVAILABLE FOR 5-3/4” (146.1) JAMB DEPTH 2” FACE ONLY AVAILABLE AS SHIP LOOSE PART ONLY

2-1/2” (63.5)

Page 13: CURRIES Tech Data Frame Section.pdf5 Masonry Face Flush KD Frame Cased Opening Frame Technical Data March, 2015 VARIES 3” (76.2) MINIMUM 1” (25.4) 1-1/4” (31.8) 1-1/2” (30.1)

10Masonry “T” AnchorFrame Technical Data

June, 2012

L

Weld in Type Masonry Anchor

L

ANCHOR PART NUMBER: P0069ORDER CODE LOOSE: M

10” (254.0)

2” (50.8)

16 GA. (1.4)

ANCHOR PART NUMBER: P0002ORDER CODE LOOSE: MLORDER CODE WELDED: WML

10-3/4” (273.1)

2” (50.8)

16 GA. (1.4)

Page 14: CURRIES Tech Data Frame Section.pdf5 Masonry Face Flush KD Frame Cased Opening Frame Technical Data March, 2015 VARIES 3” (76.2) MINIMUM 1” (25.4) 1-1/4” (31.8) 1-1/2” (30.1)

11EWA Anchor

Frame Technical DataNovember, 2004

LFOR STANDARD RABBETED FRAMES 1-15/16” (49.2) X 1-9/16” (39.7)THE EWA ANCHOR IS AVAILABLE IN 5-1/2” (139.7) & 8-1/2” (215.9) SIZES TOFIT 5-3/4” (146.1) & 8-3/4” (222.3) STANDARD RABBETED FRAMES RESPECTIVELY.3/8” FLAT HEAD BOLT RECOMMENDED.

ANCHOR PART NUMBER: P0070ORDER CODE LOOSE: EWAORDER CODE WELDED: WEWA

-AVAILABLE AS SHIP-LOOSE ANCHOR-AVAILABLE FROM WAREHOUSE AS STOCK #CF004896-SPECIFY 5-1/2” (139.7) OR 8-1/2” (215.9) SIZE

1-1/2” MIN. 18, 16, 14 GA. (38.1)

MINIMUM

5-3/4” (146.1)8-3/4” (222.3)

ARCWELD

5-3/4” (146.1)8-3/4” (222.3)

5-1/2” (139.7)8-1/2” (215.9)

2-15/16” (74.6)4-7/16” (112.7)

2-9/16” (65.1)4-1/16” (103.2)

2-9/16”(65.1)

15/16” (23.8)

1” (25.4)

THE EWA ANCHOR MAY BE TRIMMED TO FIT ANY FRAME OF STANDARD RABBET OR SINGLE RABBET 8-3/4” (222.3) OR LESS IN JAMB DEPTHAND EQUAL RABBET 8-3/8” (212.7) OR LESS IN JAMB DEPTH

* 1-1/2” MINIMUM 12 GA.

NOTE: 1-7/8 MIN. STOP WIDTH FOR QM PROFILE

DIAMETER 3/8” (9.5) X 1-3/4” (44.5)EMBEDMENT LENGTH OR STEELEXPANSION SHELL OR 3/8” (9.5)FLATHEAD BOLT

Page 15: CURRIES Tech Data Frame Section.pdf5 Masonry Face Flush KD Frame Cased Opening Frame Technical Data March, 2015 VARIES 3” (76.2) MINIMUM 1” (25.4) 1-1/4” (31.8) 1-1/2” (30.1)

12Pipe Spacer AnchorFrame Technical Data

April, 2002

L

Spacing Bracket Anchor

L

ANCHOR PART NUMBER: P0044ORDER CODE LOOSE: PSORDER CODE WELDED: WPS

NOTE: FACE DIMENSION FOR PROFILE MUST BE EQUAL

DIAMETER 3/8” (9.5) X 1-3/4” (44.5) EMBEDMENT LENGTH OR STEEL EXPANSION SHELL OR 3/8” (9.5) FLATHEAD BOLT

3/4” I.D.(19.1)

1”(25.4)

1-1/4” (31.7) MIN. 18, 16, 14 GA.*

COUNTERSUNK FLATHEAD BOLT

ARC WELD

ANCHOR PART NUMBER: P0146ORDER CODE LOOSE: SBORDER CODE WELDED: WSB

DIAMETER 3/8” (9.5) X 1-3/4” (44.5)EMBEDMENT LENGTH OR STEEL EXPANSION SHELL OR 3/8” (9.5) FLATHEAD BOLT

1-1/4” (31.7) MIN. 18, 16, 14 GA.*

COUNTERSUNK FLATHEAD BOLT

VARIES

1-13/64”(30.6)

1-13/64”(30.6)

1/2” (12.7) DIA.

16 GA. (1.4)

* 1-1/2” MIN. FOR 12 GA.

* 1-1/2” MIN. FOR 12 GA.

Page 16: CURRIES Tech Data Frame Section.pdf5 Masonry Face Flush KD Frame Cased Opening Frame Technical Data March, 2015 VARIES 3” (76.2) MINIMUM 1” (25.4) 1-1/4” (31.8) 1-1/2” (30.1)

13Steel Channel Anchor - Slip-In

Frame Technical DataDecember, 2019

LSTANDARD (FLUSH)ORDER CODE LOOSE: SCF

16 GA. (1.4)

DOUBLERABBET

SINGLE RABBET/DE

NOTE: MINIMUM FACE OF 1-1/4” (31.8) REQUIRED FOR THIS ANCHOR TYPE

OPTIONAL (RECESSED)ORDER CODE LOOSE: SCR

16 GA. (1.4)18 GA. (1.09) 5-3/4" JAMB DEPTH ONLY

Page 17: CURRIES Tech Data Frame Section.pdf5 Masonry Face Flush KD Frame Cased Opening Frame Technical Data March, 2015 VARIES 3” (76.2) MINIMUM 1” (25.4) 1-1/4” (31.8) 1-1/2” (30.1)

14Steel Channel Anchor-WeldedFrame Technical Data

December, 2019

L STANDARD (FLUSH)ORDER CODE: WSCF

16 GA. (1.4)

OPTIONAL (RECESSED)ORDER CODE: WSCR

16 GA. (1.4)

ELECTRICAL CONDUIT (RECESSED)

ORDER CODE: ESCR

SINGLE RABBET/DE

DOUBLERABBET

NOTE: FLUSH ANCHORS ALLOW FOR 3/4” (19) DRYWALL. NEED TO SPECIFY IF GREATER.FLUSH ANCHORS CAN BE USED WITH ELECTRICAL CONDUIT.

Page 18: CURRIES Tech Data Frame Section.pdf5 Masonry Face Flush KD Frame Cased Opening Frame Technical Data March, 2015 VARIES 3” (76.2) MINIMUM 1” (25.4) 1-1/4” (31.8) 1-1/2” (30.1)

15Wood Stud AnchorFrame Technical Data

January, 2017

L

Wood Stud Anchors - Double Egress

L

SLIP IN WOOD STUD ANCHOR - “M” SERIES FRAME ONLYORDER CODE LOOSE: WS “A” DIMENSIONSANCHOR PART NUMBER: P0152 - SPECIFY STUD WIDTH

WELD IN WOOD STUD ANCHOR ORDER CODE LOOSE: WWS “A” DIMENSIONSANCHOR PART NUMBER: P0148 - SPECIFY STUD WIDTH

1” (25.4)

A

9/64” (3.6) DIA.

16 GA. (1.4)

1” (25.4)

A

9/64” (3.6) DIA.

16 GA. (1.4)

1” (25.4)

A

9/64” (3.6) DIA.

16 GA. (1.4)

3-1/4” (82.6)

1” (25.4)

A

9/64” (3.6) DIA.

16 GA. (1.4)

SLIP IN WOOD STUD ANCHOR ORDER CODE LOOSE: WS “A” DIMENSIONSANCHOR PART NUMBER: P0152 - SPECIFY STUD WIDTH

WELD IN WOOD STUD ANCHOR ORDER CODE LOOSE: WWS “A” DIMENSIONSANCHOR PART NUMBER: P0148 - SPECIFY STUD WIDTH

NOTE: SPECIFY JAMB OR HEAD ANCHOR WHEN ORDERING.CURRIES WOOD STUD ANCHORS CAN BE USED WITH WOOD AND METAL STUDS.

BOTH ARE LABEL APPROVED.

Page 19: CURRIES Tech Data Frame Section.pdf5 Masonry Face Flush KD Frame Cased Opening Frame Technical Data March, 2015 VARIES 3” (76.2) MINIMUM 1” (25.4) 1-1/4” (31.8) 1-1/2” (30.1)

16Adjustable Multipurpose AnchorFrame Technical Data

October, 2010

ANCHOR PART NUMBER: P0027ANCHOR CODE: AMP“A” DIMENSION = JAMB DEPTHS OF 4-3/8” (111.1) THRU 6-3/4” (171.5)2” (50.8) FACE FLUSH “M” SERIES OR DRYWALL “C” SERIESFIELD ADJUSTED TO JAMB DEPTH. AVAILABLE AS SHIP LOOSE PART ONLY

FOR USE AS: WOOD STUD ANCHOR WIRE TRUSS ANCHOR STEEL CHANNEL ANCHOR

ANCHOR PART NUMBER: P0045ANCHOR CODE: MPJAMB DEPTHS OF 4-3/4” (120.7) THRU 9-3/4” (247.6)2” (50.8) FACE FLUSH “M” SERIES OR DRYWALL “C” SERIES2” (50.8) X 2-5/8” (66.67) “G” SERIES OR DRYWALL “CG” SERIES

Multipurpose Anchor

L

#12-24 X 1/2” (12.7)SLOTTED HEX WASHER HEAD

1/8” (3.2) DIA.

16 GA. (1.4)

A

BEND OR TRIM LEGS TO SUIT WALL CONDITIONS

BEND OR TRIM LEGS TO SUIT WALL CONDITIONS

NUMBER OF STIFFENERSDEPEND ON

JAMB DEPTHS

5/32” (4) DIA.

18 GA. (1.4)

UNEQUAL RABBETS ONLY ON MASONRY WALLS

Page 20: CURRIES Tech Data Frame Section.pdf5 Masonry Face Flush KD Frame Cased Opening Frame Technical Data March, 2015 VARIES 3” (76.2) MINIMUM 1” (25.4) 1-1/4” (31.8) 1-1/2” (30.1)

17Multipurpose Anchor Installation - Drywall Return Frame

Frame Technical DataNovember, 2004

L

2. INSERT ANCHOR INTO FRAME THROAT TILTED AT APPROXIMATELY A 50˚ ANGLE AS SHOWN IN DETAIL “B”.

3. THE ANCHOR MUST ALSO BE INSERTED AT APPROXIMATELY A 20˚ ANGLE FROM THE RABBETS OF THE FRAME AS SHOWN IN DETAIL “B”. THE FLANGES ON THE ANCHOR MUST CLEAR THE BACKBEND RETURNS.

4. TWIST THE ANCHOR INTO PLACE BY APPLYING PRESSURE IN THE OPPOSITE DIRECTIONS TO EACH SIDE OF THE ANCHOR AS SHOWN IN DETAIL “C”.

5. ONCE THE ANCHOR HAS SNAPPED INTO PLACE, DETAIL “D”, TURN IT UP INTO THE CORRECT POSITION AS SHOWN IN DETAIL “E” LEGS SHOULD BE BENT BACK TO THE ORIGINAL POSITION IF NECESSARY.

1. BEND LEGS OF ANCHOR 90˚ AS SHOWN IN DETAIL “A” (LEGS MAY HAVE TO BE BENT FURTHER IN LATER STEPS).

DETAIL “A”

DETAIL “B”

DETAIL “C”

DETAIL “D”

DETAIL “E”

50˚

20˚

PUSH

PUSH LIFT UP

P0045

Page 21: CURRIES Tech Data Frame Section.pdf5 Masonry Face Flush KD Frame Cased Opening Frame Technical Data March, 2015 VARIES 3” (76.2) MINIMUM 1” (25.4) 1-1/4” (31.8) 1-1/2” (30.1)

18Ceiling Strut AnchorFrame Technical Data

September, 2005

L

Mullion Stirrup Anchor

L

ANCHOR PART NUMBER: P01594” (101.6)

1” (25.4)

3/8” (9.5) DIA.2 PLS.

VARIES

1/4” (6.4)

STRUT1/4” (6.4) X 1” (25.4) STEEL BAR1 REQ’D

WEDGES

1/4” (6.4)1/16” (1.6)

1-1/4” (31.8)WEDGE

1-1/8” (28.6)

VARIES

STRUT GUIDE16 GA. (1.4)

2 REQ’D

1-1/8” (28.6)

1-9/16” (39.7)

ANCHOR PART NUMBER: P0089

DIMENSION “B” VARIES WITH FACE DIMENSION2” (50.8) FACE MULLION “B” EQUALS 1-1/2” (38.1)

B9/32” (7.1) DIA.

1-1/2” (38.1)

VARIES WITHJAMB DEPTH

12 GA. (2.6)FIELD INSTALL #8 SMS MINIMUM EACH FACE

Page 22: CURRIES Tech Data Frame Section.pdf5 Masonry Face Flush KD Frame Cased Opening Frame Technical Data March, 2015 VARIES 3” (76.2) MINIMUM 1” (25.4) 1-1/4” (31.8) 1-1/2” (30.1)

19Steel Channel Anchor for Lead Lined Frames

Frame Technical DataNovember, 2014

L

CONTINUOUS WELD FACE SEAMGRIND AND FINISH SMOOTH BEND TABS TOWARD WALL

CONTINUOUS WELD JOINTSOF RABBET AND SOFFIT

WELD CODE: FW L

Full Weld KD

STANDARD (FLUSH)WELD CODE: WSCF-LL

OPTIONAL (RECESSED)WELD CODE: WSCR-LL

Page 23: CURRIES Tech Data Frame Section.pdf5 Masonry Face Flush KD Frame Cased Opening Frame Technical Data March, 2015 VARIES 3” (76.2) MINIMUM 1” (25.4) 1-1/4” (31.8) 1-1/2” (30.1)

20Seam Weld Flush KDFrame Technical Data

February, 2013

L

Saw Miter Weld

L

BEND TABS TOWARD WALL

CONTINUOUS WELD FACE SEAMGRIND AND FINISH SMOOTH

CONTINUOUS WELD INSIDE OF MITER

GRIND FACE AND FINISH SMOOTH

WELD CODE SW (KD)

GRIND FACE AND FINISH SMOOTH

TACK WELD RABBET AND SOFFIT

WELD CODE SMWWELD CODE SMT

Page 24: CURRIES Tech Data Frame Section.pdf5 Masonry Face Flush KD Frame Cased Opening Frame Technical Data March, 2015 VARIES 3” (76.2) MINIMUM 1” (25.4) 1-1/4” (31.8) 1-1/2” (30.1)

21Saw Butt Weld

Frame Technical Data

April, 2002

LWELD CODE BEW (<3) WELD CODE BET (<3)

WELD CODE SBW (>3) WELD CODE SBT (>3)

Page 25: CURRIES Tech Data Frame Section.pdf5 Masonry Face Flush KD Frame Cased Opening Frame Technical Data March, 2015 VARIES 3” (76.2) MINIMUM 1” (25.4) 1-1/4” (31.8) 1-1/2” (30.1)

22Corner WeldsFrame Technical Data

July, 2003

LWELD CODE BEF 10

Page 26: CURRIES Tech Data Frame Section.pdf5 Masonry Face Flush KD Frame Cased Opening Frame Technical Data March, 2015 VARIES 3” (76.2) MINIMUM 1” (25.4) 1-1/4” (31.8) 1-1/2” (30.1)

23Splice Joints

Frame Technical Data

April, 2002

L

Saw Miter Only

LNOTE: PREPARED FOR DISTRIBUTOR WELDING

WELD CODE FSP WELD CODE WSP

WELD CODE SMO

WELD CODE EBE

EXACTNO NOTCH

WELD CODE SBE

EXACTNOTCH TOP JAMBS

NOTCH BOTH ENDS. (BLANK OR HEADS)

NOTE: FACTORY WELDED FRAMES EXCEEDING 9’ X 14’ WILL BE PRO-VIDED WITH FIELD SPLICES

Page 27: CURRIES Tech Data Frame Section.pdf5 Masonry Face Flush KD Frame Cased Opening Frame Technical Data March, 2015 VARIES 3” (76.2) MINIMUM 1” (25.4) 1-1/4” (31.8) 1-1/2” (30.1)

24Field Splice FramesFrame Technical Data

June, 2010

FRAMES FACTORY WELDED AT CURRIES:

PROVIDE FIELD SPLICES FOR FRAMES THAT EXCEED OVERALL SIZE SHOWN.

FRAMES FACTORY WELDED AT REGIONAL SERVICE CENTERS:

14’0”(4267)WIDTH

9’0” (2743)HEIGHT

9’0” (2743)WIDTH

14’0”(4267)HEIGHT

14’0”(4267)WIDTH

9’0” (2743)HEIGHT

9’0” (2743)WIDTH

14’0”(4267)HEIGHT

Page 28: CURRIES Tech Data Frame Section.pdf5 Masonry Face Flush KD Frame Cased Opening Frame Technical Data March, 2015 VARIES 3” (76.2) MINIMUM 1” (25.4) 1-1/4” (31.8) 1-1/2” (30.1)

25Die Mitered Weld Stainless Steel

Frame Technical Data

February, 2014

L

JAMB DEPTH

THROAT OPENING1” (25.4) LESS THANJAMB DEPTH

JAMBHEAD

304 OR 316 STAINLESS STEEL FINISH:2B MILL#4 BRUSHED SATIN#6 FINE SATIN#8 MIRRORXLB XL BLEND

FULL FACE WELD AND INTERMITTENT SOFFET AND RABBET WELDS

THROAT OPENING1” (25.4) LESS THANJAMB DEPTH

JAMB DEPTH

Page 29: CURRIES Tech Data Frame Section.pdf5 Masonry Face Flush KD Frame Cased Opening Frame Technical Data March, 2015 VARIES 3” (76.2) MINIMUM 1” (25.4) 1-1/4” (31.8) 1-1/2” (30.1)

26Stainless Steel Sidelight FrameFrame Technical Data

February, 2014

VERTICAL MEMBERS BUTT AT SILL AND HEAD

JAMB DEPTH

WELDED

JAMB DEPTH

L

304 OR 316 STAINLESS STEEL FINISH:2B MILL#4 BRUSHED SATIN#6 FINE SATIN#8 MIRRORXLB XL BLEND

Page 30: CURRIES Tech Data Frame Section.pdf5 Masonry Face Flush KD Frame Cased Opening Frame Technical Data March, 2015 VARIES 3” (76.2) MINIMUM 1” (25.4) 1-1/4” (31.8) 1-1/2” (30.1)

27Half Sidelite Window Option

Frame Technical Data

July, 2003

OPTION BMOST COMMON

REMOVE BACKSIDEOF MULLION

L

OPTION AAS REQUIRED

L

SPLICE WELD SECTION TO MULLIONFILL AND GROUND SMOOTH,LABELED WHEN FULLY WELDED.

OPTION CAS REQUIRED

L

FILLER PLATEWITH STOP

NOTE: MAY BE LABELED WHEN PROPERLY WELDED.

EXPOSED SEAM UNLESS FACTORY WELDED SEAM

Page 31: CURRIES Tech Data Frame Section.pdf5 Masonry Face Flush KD Frame Cased Opening Frame Technical Data March, 2015 VARIES 3” (76.2) MINIMUM 1” (25.4) 1-1/4” (31.8) 1-1/2” (30.1)

28Cut and Notch OptionsFrame Technical Data

April, 2002

L

CORNER: KD STANDARD WHEN POSSIBLE MUST MEET KD PARAMETERS SAW MITER:* IF FACES OF HEAD AND JAMB ARE EQUAL 1. EXCEPT: 4” (101.6) FACE HEAD TO 2” (50.8) FACE JAMB BUTT END:* IF FACES ARE UNEQUAL

* SMO OR SBE MUST BE NOTED IN CONSTRUCTION COLUMN.

NOTE: MAY BE LABELED WHEN PROPERLY WELDED

NOTE: MAY BE LABELED WHEN FACE WELDED

SAW MITER

BUTT END

KD

Page 32: CURRIES Tech Data Frame Section.pdf5 Masonry Face Flush KD Frame Cased Opening Frame Technical Data March, 2015 VARIES 3” (76.2) MINIMUM 1” (25.4) 1-1/4” (31.8) 1-1/2” (30.1)

29Cut and Notch Options

Frame Technical Data

April, 2002

L

STRIKE MULLION: NOTCH TOP EXCEPTION: WILL RUN THROUGH HEAD IF HEAD PROFILE IS DIFFERENT ON GLASS SIDE EXAMPLE: “M” PROFILE AT DOOR OPENING “G” PROFILE AT WINDOW SIDE RUN MULLION THROUGH IF HEAD FACES ARE DIFFERENT FROM DOOR SIDE TO GLASS SIDE OR IF FIELD SPLICE IS REQUIRED

NOTE: MAY BE LABELED WHEN PROPERLY WELDED

NOTE: PROVIDES ACCESS FOR ELECTRICAL CONDUIT OR GROUT

Page 33: CURRIES Tech Data Frame Section.pdf5 Masonry Face Flush KD Frame Cased Opening Frame Technical Data March, 2015 VARIES 3” (76.2) MINIMUM 1” (25.4) 1-1/4” (31.8) 1-1/2” (30.1)

30Cut and Notch OptionsFrame Technical Data

April, 2002

L

HORIZONTAL MULLION: NOTCH BOTH ENDS TO BUTT BETWEEN VERTICAL MEMBERS IS STANDARD PREPARATION

NOTE: MAY BE LABELED WHEN PROPERLY WELDED

NOTCH STOP OFJAMB TO RECEIVE MULLION

TYPICAL REMOVABLEMULLION PREPARATION

OPTIONAL STANDARD

Page 34: CURRIES Tech Data Frame Section.pdf5 Masonry Face Flush KD Frame Cased Opening Frame Technical Data March, 2015 VARIES 3” (76.2) MINIMUM 1” (25.4) 1-1/4” (31.8) 1-1/2” (30.1)

31Cut and Notch Options

Frame Technical Data

April, 2002

L

MULLION: NOTCH TOP AND BOTTOM, WILL RUN THROUGH FROM HEAD TO TOP OF SILL 1. EXCEPTION: WILL RUN MULLION THROUGH TO FLOOR RATHER THAN SPLICE 2 SECTIONS OF SILL TOGETHER 2. EXCEPTION: RUN MULLION THROUGH HEAD AND SILL IF FIELD SPLICE IS REQUIRED

NOTE: MAY BY LABELED WHEN PROPERLY WELDED

SILLS: NOTCH BOTH ENDS TO BUTT BETWEEN VERTICAL MEMBERS

OPTIONALSTANDARD STANDARD

Page 35: CURRIES Tech Data Frame Section.pdf5 Masonry Face Flush KD Frame Cased Opening Frame Technical Data March, 2015 VARIES 3” (76.2) MINIMUM 1” (25.4) 1-1/4” (31.8) 1-1/2” (30.1)

32Saw Butt EndFrame Technical Data

June, 2009

L

Drywall KD “CG” Profile Corner Details

NOTE: MAY BE LABELED WHEN PROPERLY WELDED

#8 SCREW (MS002485)(REQUIRED ON ALL FIRE RATED FRAMES)

L

WALL NOTCH JAMB FOR DRYWALL WALL CONSTRUCTION

OPTIONAL STANDARD

Page 36: CURRIES Tech Data Frame Section.pdf5 Masonry Face Flush KD Frame Cased Opening Frame Technical Data March, 2015 VARIES 3” (76.2) MINIMUM 1” (25.4) 1-1/4” (31.8) 1-1/2” (30.1)

33Drywall KD Frame Corner Clip Detail

Frame Technical Data

March, 2015

L

3-1/2” (88.9)

JAMB

HEAD2” FACE

2-3/8” (60.3)

2-3/8” (60.3)

#8 SCREW (MS002485)(REQUIRED ON ALLFIRE RATED FRAMES)

HEAD2” (50.8) FACE

SPOT WELDSBY CURRIES

*RETURN FILLER: P0071

HEAD4” (101.6) FACE

JAMB

WELDPROJECTIONS

C PROFILE CORNER

Page 37: CURRIES Tech Data Frame Section.pdf5 Masonry Face Flush KD Frame Cased Opening Frame Technical Data March, 2015 VARIES 3” (76.2) MINIMUM 1” (25.4) 1-1/4” (31.8) 1-1/2” (30.1)

34Security AnchorFrame Technical Data

May, 2020

L

Drywall Frame Compression Anchor

L

COMPRESSIONANCHOR

SECURITYANCHOR

45” (1143) TYPICAL

BOTTOM OF FRAME

PER JAMBDEPTH

VARIES

1-1/8” (28.6)

1-1/8” (28.6)

3-1/2” (88.9)16 GA. (1.4)

ANCHOR PART NUMBER: P407

5/8” (15.8)MAXIMUM TRAVEL

ANCHOR PART NUMBER: P0026 (2” FACE)ANCHOR PART NUMBER: P0018 (1-1/2” TO 1-3/4” FACE)

COMPRESSIONANCHOR

3-1/2” (88.9)1” (25.4)

MIN.

Page 38: CURRIES Tech Data Frame Section.pdf5 Masonry Face Flush KD Frame Cased Opening Frame Technical Data March, 2015 VARIES 3” (76.2) MINIMUM 1” (25.4) 1-1/4” (31.8) 1-1/2” (30.1)

35Drywall KD Frame Standard Base Anchor

Frame Technical Data

November, 2004

L

Drywall KD Frame Optional Base Anchor

L

3/4” (19.1)

5/8” (15.9)

2” (50.8)

ANCHOR HOLESCOUNTERSUNK

#6 SCREWBOTH SIDES

3-1/4” (82.6)

1” (25.4)

7/8” (22.2)

1/2” (12.7)

1/2” (12.7)

3/16” (4.8) DIA.

16 GA. (1.4)

ANCHOR PART NUMBER: P0087

NOTE: REQUIRED ON 1-1/2” (38.1), 1-3/4” (44.5) FACE DRYWALL FRAMES. 3”, 3-1/8”, 3-1/4”, JAMB DEPTHS.

2” FACEONLY

3/4” (19)

FLOOR

CL

MINIMUM JAMB DEPTH 3-3/8 (85.7)

Page 39: CURRIES Tech Data Frame Section.pdf5 Masonry Face Flush KD Frame Cased Opening Frame Technical Data March, 2015 VARIES 3” (76.2) MINIMUM 1” (25.4) 1-1/4” (31.8) 1-1/2” (30.1)

36Drywall CG ProfilesFrame Technical Data

March, 2015

L

Compression Anchor System Narrow Jamb Depth

L

3” (76.2) – 14” (355.6)

VARIES1-15/16” (49.2)

OR1-9/16” (39.7)

JAMB DEPTHS

2-5/8” (66.7)2” (50.8)

5/8” (25.9)

1/2” (12.7)

3/8” (9.5)

1/2” (12.7)

3/8” (9.5)

GAUGE - 18 GA. (1.2), 16 GA. (1.4)NOTE: AVAILABLE WITH 4” (101.6) FACE HEAD WITH 4-1/2” (114.3) MINIMUM JAMB DEPTH

CG PROFILE *1-3/8” (34.9) DOOR - 3” (76.2) JAMB DEPTH1-3/4” (44.5) DOOR - 3” (76.2), 3-1/8” (79.4), 3-1/4” (82.6), 3-3/8” (85.7) JAMB DEPTH

ROUGH OPENING WIDTHEQUALS NOMINAL DOOROPENING: PLUS 2-13/16” (71.4)

ROUGH OPENING HEIGHTEQUALS NOMINAL DOOROPENING: PLUS 3/4” - 1” MAX (19.1) - (25.4)

STRAP BASE ANCHOR

3/4” (19.1)

-COMPRESSION ANCHORS 3-1/2” (88.9)CL

STROKE

* “CG” PROFILE JAMB DEPTHS NOT LISTED ABOVE USE STD. DRYWALL ROUGH OPENING DIMENSIONS

CG

Optional face dimension:1" through 2" in 1/8" increments

Optional return dimension:7/16" through 1"

Rabbets can vary 5/8" through 6" on non door rabbet.

Page 40: CURRIES Tech Data Frame Section.pdf5 Masonry Face Flush KD Frame Cased Opening Frame Technical Data March, 2015 VARIES 3” (76.2) MINIMUM 1” (25.4) 1-1/4” (31.8) 1-1/2” (30.1)

37Drywall KD Frame Unequal Rabbet

Frame Technical Data

March, 2015

L

Drywall KD Frame Equal Rabbet

L

1-1/2” (38.1)1-3/4” (44.5)

2” (50.8)

5/8” (15.9)

1-15/16”(49.2)

1-9/16”(39.7)

VARIES

3/8” (9.5)

1/2”(12.7)

KD DRYWALLGAUGE - 18 GA. (1.2), 16 GA. (1.4), 14 GA. (1.9) *UNEQUAL RABBETJAMB DEPTH 4-1/2” (114.3) THRU 14” (355.6) (1/8” (3.2) INCREMENTS)2” (50.8) FACE AVAILABLE WITH 4” (101.6) HEADSNOTE: 14 GA. AVAILABLE WITH 2” (50.8) FACE ONLY

1-1/2” (38.1)1-3/4” (44.5)

2” (50.8)

5/8” (15.9)

1-15/16” (49.2)OR

1-9/16” (39.7)VARIES

3/8” (9.5)

1/2”(12.7)

1-15/16” (49.2)OR

1-9/16” (39.7)OR OR

C

C

KD DRYWALLGAUGE - 18 GA. (1.2), 16 GA. (1.4), 14 GA. (1.9) *UNEQUAL RABBETJAMB DEPTH 4-7/8” (123.8) THRU 14” (355.6) (1/8” (3.2) INCREMENTS)2” (50.8) FACE AVAILABLE WITH 4” (101.6) HEADSAVAILABLE IN COMMUNICATING FRAMESNOTE: 14 GA. AVAILABLE WITH 2” (50.8) FACE ONLY

Optional face dimension:1" through 2" in 1/8" increments

Optional return dimension:7/16" through 1"

Rabbets can vary 5/8" through 6" on non door rabbet.

Optional face dimension:1" through 2" in 1/8" increments

Optional return dimension:7/16" through 1"

Rabbets can vary 5/8" through 6" on non door rabbet.

Page 41: CURRIES Tech Data Frame Section.pdf5 Masonry Face Flush KD Frame Cased Opening Frame Technical Data March, 2015 VARIES 3” (76.2) MINIMUM 1” (25.4) 1-1/4” (31.8) 1-1/2” (30.1)

38Drywall KD Frame Cased OpeningFrame Technical Data

March, 2015

L

Drywall KD “CG” Profile Frame

L

VARIES3” (76.2) MINIMUM

1-1/2” (38.1)1-3/4” (44.45)

2” (50.8)

3/8” (9.5)

1/2” (12.7)

KD DRYWALLGAUGE - 18 GA. (1.2), 16 GA. (1.4), 14 GA. (1.9)JAMB DEPTH 3” (76.2) THRU 14” (355.6) (1/8” (3.2) INCREMENTS)14 GA. AVAILABLE W/2” FACE ONLY

NOTE: AVAILABLE WITH 4” (101.6) FACE HEAD WITH 4-1/2” (114.3) MINIMUM JAMB DEPTH WITH 2” FACE JAMBS ONLY.

VARIES

2” (50.8)

3/8” (9.5)

1/2” (12.7)

1-15/16” (49.2)

1-9/16” (39.7)OR

5/8” (50.8)

2-5/8” (66.7)

KD “CG” PROFILE DRYWALLGAUGE - 18 GA. (1.2), 16 GA. (1.4)JAMB DEPTH 3” (76.2) THRU 14” (355.6) (1/8” (3.2) INCREMENTS)NOTE: 2” (50.8) AND 2-5/8” (66.7) FACE ONLY

CK

CG

Optional face dimension:1" through 2" in 1/8" increments

Optional return dimension:7/16" through 1"

Optional face dimension:1" through 2" in 1/8" increments

Optional return dimension:7/16" through 1"

Rabbets can vary 5/8" through 6" on non door rabbet.

Page 42: CURRIES Tech Data Frame Section.pdf5 Masonry Face Flush KD Frame Cased Opening Frame Technical Data March, 2015 VARIES 3” (76.2) MINIMUM 1” (25.4) 1-1/4” (31.8) 1-1/2” (30.1)

39Drywall Cased Opening Compression Anchor

Frame Technical Data

April, 2013

CM Profile Frames

L

L

2” (50.8) LEG

STIFFENER PART NUMBER: P0093

16 GA. (1.4)

VARIES2” (50.8)

3/4” (19.1)

NOTE: STIFFENER ADDED TO PREVENT DISTORTION OF FRAME WHEN TIGHTENING ANCHOR

FOOTCLIPS

CM 3-1/2” (88.9) - 14” (355.6)CMG 3” (76.2) - 14” (355.6)

2” (50.8) CM CMG

CM PROFILE FRAMES DO NOT HAVE THE COMPRESSION BAR NOR BASE ANCHORS. THEY DO HAVE FOOTCLIPS WELDED IN AND ARE FURNISHED WITH LOOSE DRYWALL ANCHORS, WELDED IN ANCHORS ARE OPTIONAL. SAME K.D. CORNER CAPABILITIES AS THE C FRAME.

3/8” (9.5)

1/2” (12.7)

Page 43: CURRIES Tech Data Frame Section.pdf5 Masonry Face Flush KD Frame Cased Opening Frame Technical Data March, 2015 VARIES 3” (76.2) MINIMUM 1” (25.4) 1-1/4” (31.8) 1-1/2” (30.1)

40Drywall KD Frame (“C” Profile) Installation InstructionsFrame Technical Data

July, 2009

4

5

3

68 7 8

9

10

1. CONSTRUCT WALL WITH ROUGH OPENING HEIGHT EQUAL TO FINISHED OPENING HEIGHT PLUS 3/4” (19.1) TO 1” (25.4) MAX., ROUGH OPENING WIDTH IS AS FOLLOWS: A) FOR 2” (50.8) FACE FRAMES-OPENING WIDTH PLUS 2-1/8” (54.0) TO 2-3/8” (60.3) B) FOR 1-3/4” (44.5) AND 1-1/2” (38.1) FACE FRAMES-OPENING WIDTH PLUS 2” (50.8) C) FOR “C” AND “CG” PROFILES, 3” (76.2) JAMB DEPTH 1-9/16” (39.7) RABBET AND 3” (76.2), 3-1/8” (79.4), 3-1/4” (82.6) AND 3-3/8” (85.7) JAMB DEPTH 1-15/16” (49.2) RABBET FRAMES-OPENING WIDTH PLUS 2-13/16” (71.4), ALL OTHER “C” AND “CG” PROFILE FRAMES-OPENING WIDTH PLUS 2-1/8” (54.0) TO 2-3/8” (60.3) d) FOR 2” (508) FACE CASED OPENING - OPENING WIDTH PLUS 2-1/4” (572)

2. BOTTOM OF FRAME MUST SET ON A SOLID SURFACE.

3. IF WRAP-AROUND BASE ANCHOR IS USED, NOTCH DRYWALL IN THAT AREA.

4. RETRACT COMPRESSION BARS IN THE JAMBS BY TURNING SCREWS COUNTER CLOCKWISE AND INSTALL ONE JAMB IN POSITION ON WALL.

5. INSERT FRAME HEAD UNDER THE CORNER CLIPS OF THE JAMB AND RAISE INTO POSITION.

6. INSERT THE CORNER CLIPS OF THE REMAINING JAMB INTO THE OPPOSITE END OF THE HEAD AND POSITION JAMB ON WALL.

7. LOCATE A REMOVABLE FRAME SPACING BAR AT BASE OF CENTERED FRAME TO MAINTAIN PROPER OPENING WIDTH DURING INSTALLATION.

8. LEVEL, SQUARE AND PLUMB FRAME AND INSTALL BASE ANCHOR SCREWS THROUGH COUNTERSINK HOLES IN FRAME FACE AND INTO FLOOR PLATE.

9. SQUARE TOP OF FRAME AND TIGHTEN COMPRESSION BARS BY TURNING SCREWS CLOCKWISE. (DO NOT OVERTIGHTEN).

10. INSTALL (4) NO. 8 X 1/2” (12.7) SHEET METAL SCREWS AT THE CORNERS OF THE HEAD TO ATTACH HEAD TO JAMBS (REQUIRED FOR FIRE RATED FRAMES).

L

2

Page 44: CURRIES Tech Data Frame Section.pdf5 Masonry Face Flush KD Frame Cased Opening Frame Technical Data March, 2015 VARIES 3” (76.2) MINIMUM 1” (25.4) 1-1/4” (31.8) 1-1/2” (30.1)

41Drywall KD Borrowed Lite

Frame Technical Data

July, 2007

L

OVERALL FRAMEWIDTH

NOTE A: ROUGH OPENING HEIGHT FOR 2” (50.8) FACE FRAMES EQUALS GLASS OPENING SIZE PLUS 2-1/2” (63.5) INCLUDING CASED OPENING NOTE A: ROUGH OPENING HEIGHT FOR 1-1/2” (38.1) & 1-3/4” (44.5) FACE FRAMES EQUALS GLASS OPENING SIZE PLUS 2” (50.8)NOTE B: ROUGH OPENING WIDTH FOR 2” (50.8) FACE FRAMES EQUALS GLASS OPENING SIZE PLUS 2-1/2” (63.5) INCLUDING CASED OPENING ROUGH OPENING WIDTH FOR 1-1/2” (38.1) & 1-3/4” (44.5) FACE FRAMES EQUALS GLASS OPENING SIZE PLUS 2” (50.8)

NOTE:5/8” (15.8) X 5/8” (15.8) GLASS STOPSARE PUNCHED AND CUT TO LENGTH REMOVABLE STOPS MATCH FIXED STOPLENGTH AND ARE SHIPPED LOOSE

KD BORROWED LITE (DRYWALL FRAME ONLY)ORDER OF INSTALLATION - A) PLACE RIGHT SIDE VERTICAL JAMB MEMBER INTO OPENING; B) INSTALL SILL MEMBER AND ASSEMBLE CORNER #1; C) THEN INSTALL HEAD MEMBER AND ASSEMBLE CORNER #2 D) WHILE INSTALLING THE REMAINING LEFT VERTICAL JAMB MEMBER IT MAY BE NECESSARY TO EXTEND THE HEAD (CORNER #3) AND SILL (CORNER #4) TO THEIR ROUGH OPENING LIMITATIONS FOR EASIER INSTALLATION; E) THEN ASSEMBLE CORNER #3 AND FINALLY SNAP INTO POSI-TION THE REMAINING CORNER #4; F) INSTALL SCREWS THROUGH FRAME RETURNS INTO CORNER CLIPS; G) ADJUST COM-PRESSION BARS UNTIL LEVEL AND PLUMB.

GLASS OPENING1’6” (457.2) MINIMUM

ROUGH OPENINGHEIGHT

SEE NOTE A

OVERALL FRAMEHEIGHT

GLASSOPENING

VARIABLE FACE

ROUGH OPENING WIDTHSEE NOTE B

CL

CL

COMP.BAR

STD.

CL

CL

COMP.BAR

STD.

33

44 1

1

22

4” (101.6) FACE HEADS & SILLSARE NOT AVAILABLE.

“CG” PROFILE - SEE NEXT PAGE

VARIABLE FACE

Page 45: CURRIES Tech Data Frame Section.pdf5 Masonry Face Flush KD Frame Cased Opening Frame Technical Data March, 2015 VARIES 3” (76.2) MINIMUM 1” (25.4) 1-1/4” (31.8) 1-1/2” (30.1)

42Single Rabbet Drywall KD Borrowed LiteFrame Technical Data

July, 2007

L

OVERALL FRAMEWIDTH

“CG” PROFILE - COMPRESSION BAR RABBET MOUNTED.JAMB DEPTHS INCLUDE 3” (76.2), 3-1/8” (79.4), 3-1/4” (82.5), 3-3/8” (85.7) X 1-15/16” (49.2) RABBETAND 3” (76.2) X 1-9/16” (39.7) RABBET

NOTE A: ROUGH OPENING HEIGHT FOR 2” (50.8) FACE FRAMES EQUALS GLASS OPENING SIZE PLUS 2-3/4” (69.8)NOTE B: ROUGH OPENING WIDTH FOR 2” (50.8) FACE FRAMES EQUALS GLASS OPENING SIZE PLUS 2-1/2” (63.5)

KD BORROWED LITE (DRYWALL FRAME ONLY)ORDER OF INSTALLATION - A) PLACE RIGHT SIDE VERTICAL JAMB MEMBER INTO OPENING; B) INSTALL SILL MEMBER AND ASSEMBLE CORNER #1; C) THEN INSTALL HEAD MEMBER AND ASSEMBLE CORNER #2 D) WHILE INSTALLING THE REMAINING LEFT VERTICAL JAMB MEMBER IT MAY BE NECESSARY TO EXTEND THE HEAD (CORNER #3) AND SILL (CORNER #4) TO THEIR ROUGH OPENING LIMITATIONS FOR EASIER INSTALLATION; E) THEN ASSEMBLE CORNER #3 AND FINALLY SNAP INTO POSI-TION THE REMAINING CORNER #4; F) INSTALL SCREWS THROUGH FRAME RETURNS INTO CORNER CLIPS. G) ADJUST COM-PRESSION BARS UNTIL LEVEL AND PLUMB.

GLASS OPENING1’6” (457.2) MINIMUM

HEIGHTWIDTH

SEE NOTE A

OVERALL FRAMEHEIGHT

GLASSOPENING

VARIABLE FACE

ROUGH OPENING WIDTHSEE NOTE B

CL

CL

COMP.BAR

CL

CL

COMP.BAR

33

44 1

1

22

4”(101.6)

4”(101.6) #8 SHEET

METAL SCREW(8 PLACES)

VARIABLE FACE

Page 46: CURRIES Tech Data Frame Section.pdf5 Masonry Face Flush KD Frame Cased Opening Frame Technical Data March, 2015 VARIES 3” (76.2) MINIMUM 1” (25.4) 1-1/4” (31.8) 1-1/2” (30.1)

43Throat Filler for Drywall Frames

Frame Technical Data

April, 2002

INSTALLATION

1. FOR BEST RESULTS INSTALL FRAME IN OPENING FIRST. DO NOT TIGHTEN COMPRESSION ANCHORS.

2. CUT JAMB FILLER STRIPS TO OVERALL LENGTH OF JAMB BACKBEND. CUT HEAD FILLER STRIP 1” (25.4) UNDER OVERALL LENGTH OF HEAD BACKBEND.

3. REMOVE PROTECTIVE FILM FROM ADHESIVE TAPE AND APPLY FILLER STRIPS TO FRAME BACKBENDS WITH 1/8” (3.2) THICK LEG BETWEEN BACKBEND RETURN AND WALL. APPLY PRESSURE TO SEAT FIRMLY.

4. SQUARE FRAME, TIGHTEN COMPRESSION ANCHORS, INSTALL BASE ANCHORS AND RESEAT FILLER STRIPS IF NECESSARY.

FILLER EQUALS OVERALL LENGTH OF BACKBEND

1/2” (12.7)

1/2” (12.7)LENGTH OF

HEAD FILLER

OVERALL LENGTH OF HEAD BACKBEND

THROAT FILLER STRIPS ARE MADE OF WHITE RIGID PVC WITH RESILIENT DOUBLE FACE TAPE FOR APPLICATION TO THE FRAME BACKBEND OR AFTER THE FRAME HAS BEEN INSTALLED.

SUPPLIED IN LENGTHS OF 7 FT. 3 IN. (2209.8) TO ACCOMMODATE MOST JAMB HEIGHTS WITH A CONTINUOUS STRIP.

NOTE: THROAT FILLER IS NOT ALLOWED ON LABEL FRAMES

THROAT REDUCEDBY 1/8” (3.2)

ONE FILLER STRIP

THROAT REDUCEDBY 1/4” (6.4)

TWO FILLER STRIPS

1/8” (3.2)DOUBLE FACE TAPE

FULL SIZE

L

Page 47: CURRIES Tech Data Frame Section.pdf5 Masonry Face Flush KD Frame Cased Opening Frame Technical Data March, 2015 VARIES 3” (76.2) MINIMUM 1” (25.4) 1-1/4” (31.8) 1-1/2” (30.1)

44CURRIES Standard Hinge & Strike Locations for 1-3/4” FramesFrame Technical Data

September, 2013

L

* STRIKE BACKSET: 5/16” (7.9) FOR 1-3/4” (44.5) DOOR 1/2” (12.7) FOR 2” (50.8) DOOR

CL

CL

CL

CL

A

B

B

C

40” (1016) STANDARD

HINGE SIZE MAY VARY LOCATION REMAINS THE SAMEHINGE BACKSET: 5/16” (7.9) FOR 1-3/4” (44.5) DOOR 5/8” (15.9) FOR 2” (50.8) DOOR 5/8” (15.9) FOR 2-1/4” (57.2) DOORDOOR RABBETS: 1-15/16” (49.2) FOR 1-3/4” (44.5) DOOR 2-3/16” (55.6) FOR 2” (50.8) DOOR

FOR USE WITH THREE HINGES4-1/2” (114.3) OR 5” (127) *

4-7/8” (123.8)STRIKE

SIZE A B C 6’8” (2032) 7-1/4” (184.2) 30-1/4” (768.4) 12-1/4” (311.2) 6’10” (2082.8) 7-1/4” (184.2) 31-1/4” (793.8) 12-1/4” (311.2) 7’0” (2133.6) 7-1/4” (184.2) 32-1/4” (819.2) 12-1/4” (311.2) 7’2” (2184.4) 7-1/4” (184.2) 33-1/4” (844.6) 12-1/4” (311.2) 7’10” (2387.6) 7-1/4” (184.2) 37-1/4” (946.2) 12-1/4” (311.2) 8’0” (2438.4) 7-1/4” (184.2) 38-1/4” (971.6) 12-1/4” (311.2)

LLLLL

CL

NOTE: FOR FRAMES UNDER 60” TALL WE WILL CENTER THE STRIKE FOR ALL MANUFACTURERS LOCA-TIONS UNLESS NOTED OTHER-WISE ON THE ORDER.

Page 48: CURRIES Tech Data Frame Section.pdf5 Masonry Face Flush KD Frame Cased Opening Frame Technical Data March, 2015 VARIES 3” (76.2) MINIMUM 1” (25.4) 1-1/4” (31.8) 1-1/2” (30.1)

45CURRIES Standard Hinge & Strike Locations for 1-3/4” Frames

Frame Technical DataSeptember, 2013

L SIZE A B C

6’8” (2032) 7-1/4” (184.2) 20-1/8” (511.2) 12-3/8” (314.3) 6’10” (2082.8) 7-1/4” (184.2) 20-7/8” (530.2) 12-1/8” (308) 7’0” (2133.6) 7-1/4” (184.2) 21-1/2” (546.1) 12-1/4” (311.2) 7’2” (2184.4) 7-1/4” (184.2) 22-1/8” (562) 12-3/8” (314.3) 7’10” (2387.6) 7-1/4” (184.2) 24-7/8” (631.8) 12-1/8” (308) 8’0” (2438.4) 7-1/4” (184.2) 25-1/2” (647.7) 12-1/4” (311.2) 9’0” (2743.2) 7-1/4” (184.2) 29-1/2” (749.3) 12-1/4” (311.2) 10’0” (3048) 7-1/4” (184.2) 33-1/2” (850.9) 12-1/4” (311.2)

LLLLLLL

* STRIKE BACKSET: 5/16” (7.9) FOR 1-3/4” (44.5) DOOR 1/2” (12.7) FOR 2” (50.8) DOOR

CL

CL

CL

CL

CL

A

B

B

C

40” (1016) STANDARD

HINGE SIZE MAY VARY LOCATION REMAINS THE SAME.HINGE BACKSET: 5/16” (7.9) FOR 1-3/4” (44.5) DOOR. 5/8” (15.9) FOR 2” (50.8) DOORDOOR RABBETS: 1-15/16” (49.2) FOR 1-3/4” (44.5) DOOR. 2-3/16” (55.6) FOR 2” (50.8) DOOR.

FOR USE WITH FOUR HINGES4-1/2” (114.3) OR 5” (127) *

4-7/8” (123.8)STRIKE

B

CL

NOTE: FOR FRAMES UNDER 60” TALL WE WILL CENTER THE STRIKE FOR ALL MANUFACTURERS LOCA-TIONS UNLESS NOTED OTHER-WISE ON THE ORDER.

Page 49: CURRIES Tech Data Frame Section.pdf5 Masonry Face Flush KD Frame Cased Opening Frame Technical Data March, 2015 VARIES 3” (76.2) MINIMUM 1” (25.4) 1-1/4” (31.8) 1-1/2” (30.1)

46CURRIES Standard Hinge & Strike Locations for 1-3/8” FramesFrame Technical Data

September, 2013

SIZE A B C 6’8” (2032) 9-3/4” (247.7) 59-7/8” (1520.8) 10-3/8” (263.5) 6’10” (2082.8) 9-3/4” (247.7) 61-7/8” (1571.6) 10-3/8” (263.5) 7’0” (2133.6) 9-3/4” (247.7) 63-7/8” (1622.4) 10-3/8” (263.5) 7’2” (2184.4) 9-3/4” (247.7) 65-7/8” (1673.2) 10-3/8” (263.5)

CL

CL

CL

A

B

C

40-5/16” (1023.9) STANDARD

HINGE BACKSET: 5/16” (7.9)

FOR USE WITH TWO HINGES 1-3/8” (34.9) DOOR3-1/2” (88.9) OR 4” (101.6)

STRIKE BACKSET 3/16” (4.8)

2-3/4” (69.9)

STRIKE

LLLL

HINGE SIZE MAY VARY, LOCATION REMAINS THE SAME.CL

NOTE: FOR FRAMES UNDER 60” TALL WE WILL CENTER THE STRIKE FOR ALL MANUFACTURERS LOCA-TIONS UNLESS NOTED OTHER-WISE ON THE ORDER.

Page 50: CURRIES Tech Data Frame Section.pdf5 Masonry Face Flush KD Frame Cased Opening Frame Technical Data March, 2015 VARIES 3” (76.2) MINIMUM 1” (25.4) 1-1/4” (31.8) 1-1/2” (30.1)

47CURRIES Standard Hinge & Strike Locations for 1-3/8” Frame

Frame Technical Data

September, 2013

LL

SIZE A B C 6’8” (2032) 9-3/4” (247.7) 29-15/16” (760.4) 10-3/8” (263.5) 6’10” (2082.8) 9-3/4” (247.7) 30-15/16” (785.8) 10-3/8” (263.5) 7’0” (2133.6) 9-3/4” (247.7) 31-15/16” (811.2) 10-3/8” (263.5) 7’2” (2184.4) 9-3/4” (247.7) 32-15/16” (836.6) 10-3/8” (263.5)

CL

CL

CL CL

A

B

C

40-5/16” (1023.9) STANDARD

HINGE BACKSET: 5/16” (7.9)

FOR USE WITH THREE HINGES 1-3/8” (34.9) DOOR3-1/2” (88.9) OR 4” (101.6)

STRIKE BACKSET 3/16” (4.8)

2-3/4” (69.9)

STRIKE

LLL

B

HINGE SIZE MAY VARY, LOCATION REMAINS THE SAME.CL

NOTE: FOR FRAMES UNDER 60” TALL WE WILL CENTER THE STRIKE FOR ALL MANUFAC-TURERS LOCATIONS UNLESS NOTED OTHERWISE ON THE ORDER.

Page 51: CURRIES Tech Data Frame Section.pdf5 Masonry Face Flush KD Frame Cased Opening Frame Technical Data March, 2015 VARIES 3” (76.2) MINIMUM 1” (25.4) 1-1/4” (31.8) 1-1/2” (30.1)

48CURRIES Standard Hinge & Strike Locations for 1-3/4” Dutch FrameFrame Technical DataNovember, 2004

L

CL

CL

CL

CLCL

CL

A

B

E

35” (889) STANDARD

HINGE BACKSET: 5/16” (7.9)

DUTCH DOOR4-1/2” (114.3) OR 5” (127)

STRIKE BACKSET 5/16” (7.9)

4-7/8” (123.8)STRIKE

D

C

50” (1270) STANDARD

SHELF HEIGHT IS42” (1066.8) STANDARD

NOTE: MAXIMUM FIRE LABEL WIDTH: 3’8” (1117.6)

L

SIZE A B C D E 6’8” (2032) 7-1/4” (184.2) 24-1/4” (616) 13-1/2” (342.9) 22-3/4” (577.9) 12-1/4” (311.2) 6’10” (2082.8) 7-1/4” (184.2) 26-1/4” (666.6) 13-1/2” (342.9) 22-3/4” (577.9) 12-1/4” (311.2) 7’0” (2133.6) 7-1/4” (184.2) 28-1/4” (717.6) 13-1/2” (342.9) 22-3/4” (577.9) 12-1/4” (311.2) 7’2” (2184.4) 7-1/4” (184.2) 30-1/4” (768.4) 13-1/2” (342.9) 22-3/4” (577.9) 12-1/4” (311.2) 7’10” (2387.6) 7-1/4” (184.2) 35-1/4” (895.4) 16-1/2” (419.1) 22-3/4” (577.9) 12-1/4” (311.2) 8’0” (2438.4) 7-1/4” (184.2) 37-1/4” (946.2) 16-1/2” (419.1) 22-3/4” (577.9) 12-1/4” (311.2) 9’0” (2743.2) 7-1/4” (184.2) 49-1/4” (1251) 16-1/2” (419.1) 22-3/4” (577.9) 12-1/4” (311.2) 10”0” (3048) 7-1/4” (184.2) 61-1/4” (1555.8) 16-1/2” (419.1) 22-3/4” (577.9) 12-1/4” (311.2)

LLLLLLL

HINGE SIZE MAY VARY, LOCATION REMAINS THE SAME.CL

PLEASE INDICATE WHEN ADA COMPLIANCE IS REQUIRED. 48” CL IS NOT PRACTICAL WITH SOME DEADLOCKS.

* *

Page 52: CURRIES Tech Data Frame Section.pdf5 Masonry Face Flush KD Frame Cased Opening Frame Technical Data March, 2015 VARIES 3” (76.2) MINIMUM 1” (25.4) 1-1/4” (31.8) 1-1/2” (30.1)

49Frame Standard Rabbet Dimensions

Frame Technical Data

April, 2002

L

DOUBLE RABBET

SINGLE RABBET

MULLION

2” (50.8)

5/8” (15.8)

VARIES

1/2” (12.7)

DOOR THICKNESS DIMENSIONS

1-3/8” 1-15/16” (49.2) 1-3/4” 1-9/16” (39.7) 2”* 1-9/16” (39.7) 2-1/4”* 1-9/16” (39.7)

DOOR THICKNESS DIMENSIONS

1-3/8” 1-9/16” (39.7) 1-3/4” 1-15/16” (49.2) 2”* 2-3/16” (55.5) 2-1/4”* 2-7/16”

2” (50.8)

5/8” (15.8)

VARIES

1/2” (12.7)

DOOR THICKNESS DIMENSIONS

1-3/8” 1-9/16” (39.7) 1-3/4” 1-15/16” (49.2) 2”* 2-3/16” (55.5) 2-1/4”* 2-7/16”

2” (50.8)

5/8” (15.8)

VARIES

DOOR THICKNESS DIMENSIONS

1-3/8” 1-15/16” (49.2) 1-3/4” 1-9/16” (39.7) 2”* 1-9/16” (39.7) 2-1/4”* 1-9/16” (39.7)

DOOR THICKNESS DIMENSIONS

1-3/8” 1-9/16” (39.7) 1-3/4” 1-15/16” (49.2) 2”* 2-3/16” (55.5) 2-1/4”* 2-7/16”

* NOT AVAILABLE KNOCKDOWN (KD)

Page 53: CURRIES Tech Data Frame Section.pdf5 Masonry Face Flush KD Frame Cased Opening Frame Technical Data March, 2015 VARIES 3” (76.2) MINIMUM 1” (25.4) 1-1/4” (31.8) 1-1/2” (30.1)

504-1/2” Ultima Hinge ReinforcementFrame Technical Data

July, 2010

L

TO REMOVE SHIM PLATE, INSERT FLAT SCREWDRIVER BETWEEN SHIM AND REINFORCEMENT, AND PRY SHIM AWAY FROM REINFORCEMENT.

NOTE: 1) IF SHIM IS REMOVED, PRIME PAINT HINGE REINFORCEMENT. 2) NOT RECOMMENDED FOR CONVERSION TO ELECTRIC HINGE PREPARATION.

DEFAULT REINFORCEMENT FOR ALL 4-1/2” STANDARD AND HEAVYWEIGHT HINGES

DRILLED AND TAPPED PER HINGE TEMPLATE

PROJECTIONS FOR RESISTANCE WELDING

5-9/16” (141.3)

9” (228.6)

1-7/32” (30.9)

18 GA. (1.2) STEEL SHIM PLATE

7 GA. (4.5) STEEL

MUDCAP STANDARD ON “M” SERIES FRAME

OFFSET IN 16 GA. (1.4) FRAMEWITH SHIM PLATE .134” (3.4)WITHOUT SHIM PLATE .180 (4.6)

.134” (3.4) .180” (4.6)

Page 54: CURRIES Tech Data Frame Section.pdf5 Masonry Face Flush KD Frame Cased Opening Frame Technical Data March, 2015 VARIES 3” (76.2) MINIMUM 1” (25.4) 1-1/4” (31.8) 1-1/2” (30.1)

515” Hinge Reinforcement

Frame Technical Data

November, 2004

Heavy 5” Hinge Reinforcement

L

DRILLED AND TAPPED PERHINGE TEMPLATESTD. 12-24

PROJECTIONS FORRESISTANCE WELDING

5-9/16” (141.3)

9” (228.6)

7 GA. (4.5) STEEL

PROJECTIONS FORRESISTANCE WELDING

INDICATES HEAVY WEIGHT HINGE REINFORCEMENT

DRILLED AND TAPPED PERHINGE TEMPLATESTD. 12-24

NOTE: ELECTRICAL HINGE PREPARATION AVAILABLE PER TEMPLATE

5-9/16” (141.3)

9” (228.6)

7 GA. (4.5) STEEL

1-5/8”(41.3)

1-5/8”(41.3)

L

Page 55: CURRIES Tech Data Frame Section.pdf5 Masonry Face Flush KD Frame Cased Opening Frame Technical Data March, 2015 VARIES 3” (76.2) MINIMUM 1” (25.4) 1-1/4” (31.8) 1-1/2” (30.1)

52EH - Electric HingesFrame Technical Data

July, 2011

PER TEMPLATE

5/8” X 13/16”SLOTS TYPICAL

TYPICAL 4-1/2” ELECTRIC HINGE PREPARATION SHOWN FITS MANY ELECTRIC HINGES. OTHER ELEC-TRIC HINGE PREPARATIONS WILL BE PREPARED PER THE HINGE TEMPLATE.

NOTE: ELECTRIFIED HINGE REINFORCEMENT AVAILABLE AS LOOSE PART #FH0300

Page 56: CURRIES Tech Data Frame Section.pdf5 Masonry Face Flush KD Frame Cased Opening Frame Technical Data March, 2015 VARIES 3” (76.2) MINIMUM 1” (25.4) 1-1/4” (31.8) 1-1/2” (30.1)

53HFG Hinge Strap Reinforcement

Frame Technical Data

October, 2013

L

WELD AS SHOWN

7 GA. (4.5) X 1-1/4” (31.8) X 9” (229)HINGE REINFORCEMENT.DRILLED AND TAPPED FOR 12-24 UNC (STANDARD)(1/4-20 UNC OPTIONAL)

HOLE FOR ABUSE-RESISTANT STUD(OPTIONAL)

HIGH FREQUENCY HINGE REINFORCEMENT STRAPS14 GA. (2.0) REINFORCEMENT

MUDCAP

Page 57: CURRIES Tech Data Frame Section.pdf5 Masonry Face Flush KD Frame Cased Opening Frame Technical Data March, 2015 VARIES 3” (76.2) MINIMUM 1” (25.4) 1-1/4” (31.8) 1-1/2” (30.1)

54Full Width Hinge ReinforcementFrame Technical Data

November, 2004

L

7 GA. (4.5) X JAMB DEPTH MINUS 1/2” (12.7) X 10” (254) HINGE REINFORCEMENT.DRILLED AND TAPPED FOR 12-24 UNC (STANDARD)(1/4-20 UNC OPTIONAL)

HOLE FOR ABUSE-RESISTANT STUD(OPTIONAL)

COVERBOX

ARC WELD FULL WIDTH ALONG EACH END IN RABBETS (ONLY WHEN SPECIFIED).STANDARD WELDS INDICATED WITH AT END.

Page 58: CURRIES Tech Data Frame Section.pdf5 Masonry Face Flush KD Frame Cased Opening Frame Technical Data March, 2015 VARIES 3” (76.2) MINIMUM 1” (25.4) 1-1/4” (31.8) 1-1/2” (30.1)

55Continuous Hinge Reinforcement

Frame Technical Data

September, 2005

L

3/4” (19.1)

12 GA. (2.6)REINFORC-ING

1/4” (6.4)

1/4” (6.4)

3/4” (19.1)

12 GA. (2.6)REINFORC-ING

SURFACE MOUNTED TYPE CONCEALED MOUNTED TYPE

HGCF CODE

NOTE: HINGE MANUFACTURERS RECOMMEND REINFORCEMENTS ON 20, 18, 16 GAUGE FRAMES.

HGCR CODE

Page 59: CURRIES Tech Data Frame Section.pdf5 Masonry Face Flush KD Frame Cased Opening Frame Technical Data March, 2015 VARIES 3” (76.2) MINIMUM 1” (25.4) 1-1/4” (31.8) 1-1/2” (30.1)

56Security Hinge and Grout GuardFrame Technical Data

November, 2004

LARC WELD FULL WIDTH ALONG EACH END

PROJECTIONS FOR RESISTANCE WELDING

7 GA. (4.5) X 1-19/32” (40.4) X 9” (228.6)HINGE REINFORCEMENT.DRILLED AND TAPPED FOR 12-24 UNC (STANDARD)(1/4-20 UNC OPTIONAL)OFFSET PER HINGE THICKNESS

HOLE FOR ABUSE-RESISTANT STUDPER TEMPLATE AS REQUIRED.

16 GA. (1.4) COVERBOX SPOT WELDED OVER HINGE REINFORCING.

Page 60: CURRIES Tech Data Frame Section.pdf5 Masonry Face Flush KD Frame Cased Opening Frame Technical Data March, 2015 VARIES 3” (76.2) MINIMUM 1” (25.4) 1-1/4” (31.8) 1-1/2” (30.1)

57Electric Hinge and Grout Guard

Frame Technical Data

November, 2004

LARC WELD FULL WIDTH ALONG EACH END(OPTIONAL)

WELD PROJECTIONS FOR RESISTANCE WELDING

7 GA. (4.5) X 1-19/32” (40.4) X 9” (228.6)HINGE REINFORCEMENT.DRILLED AND TAPPED FOR 12-24 UNC (STANDARD)(1/4-20 UNC OPTIONAL)OFFSET PER HINGE THICKNESS

ELECTRICAL CONDUIT KNOCKOUT

16 GA. (1.4) GROUT GUARD COVERBOX SPOT WELDED OVER HINGE REINFORCING.

#8 PAN HEAD SCREWELECTRICAL HINGE WIRE ACCESS HOLE PER TEMPLATE.

NOTE: JUNCTION BOXES ARE NOT CAULKED AT THE FACTORY. TO BE FIELD CAULKED BY INSTALLATION CONTRACTOR.

Page 61: CURRIES Tech Data Frame Section.pdf5 Masonry Face Flush KD Frame Cased Opening Frame Technical Data March, 2015 VARIES 3” (76.2) MINIMUM 1” (25.4) 1-1/4” (31.8) 1-1/2” (30.1)

58HGA - Anchor Hinge PreparationFrame Technical Data

April, 2002

L

7 GA. (4.5) HINGE REINF.

CURRIES DOES NOT DRILL AND TAPFOR HINGE SCREWS, UNLESS FRAME ISFACTORY WELDED AND PHYSICALSAMPLES ARE PROVIDED.

IF FRAME IS STICK OR KD THE PARTS ARESHIPPED LOOSE AND ARE NOT WELDED TO-GETHER, DRILL AND TAP IN FIELD.

ARC WELD

DOOR RABBET IS 1-15/16” (49.2)

Page 62: CURRIES Tech Data Frame Section.pdf5 Masonry Face Flush KD Frame Cased Opening Frame Technical Data March, 2015 VARIES 3” (76.2) MINIMUM 1” (25.4) 1-1/4” (31.8) 1-1/2” (30.1)

59HGD - Hinge - Double Acting

Frame Technical Data

April, 2002

L12 GA. (2.6)REINFORCING

.25 (6.4)

VERTICAL JAMB LINE

2.25 (57.2)

3.375(85.7)

NOMINALDOOR HEIGHT

Page 63: CURRIES Tech Data Frame Section.pdf5 Masonry Face Flush KD Frame Cased Opening Frame Technical Data March, 2015 VARIES 3” (76.2) MINIMUM 1” (25.4) 1-1/4” (31.8) 1-1/2” (30.1)

60Pocket Pivot PreparationFrame Technical Data

April, 2002

L

5/8” (15.9) STOP HEIGHTIF USING COVERBOX

7 GA. (4.5) REINF. TAB

PREPARATION:SIZE, DRILL AND TAP PER TEMPLATE

16 GA. (1.4) COVERBOX

PER TEMPLATE

PER TEMPLATE

NOTE: SOME POCKET PIVOTS REQUIRE FRAME FACE DIMENSIONS GREATER THAN 2” (50.8) - KD FRAMES NOT AVAILABLE OVER 2” FACE.

Page 64: CURRIES Tech Data Frame Section.pdf5 Masonry Face Flush KD Frame Cased Opening Frame Technical Data March, 2015 VARIES 3” (76.2) MINIMUM 1” (25.4) 1-1/4” (31.8) 1-1/2” (30.1)

61SDL - Strike - Double Lip

Frame Technical DataNovember, 2004

L

PER TEMPLATE

PER TEMPLATE

12 GA. (2.6)REINFORCING TABS

NOTE: CONTACT FACTORY ON AVAIL-ABILITY WHEN USED WITH “C” TYPE COMPRESSION ANCHOR KD FRAMES.

Page 65: CURRIES Tech Data Frame Section.pdf5 Masonry Face Flush KD Frame Cased Opening Frame Technical Data March, 2015 VARIES 3” (76.2) MINIMUM 1” (25.4) 1-1/4” (31.8) 1-1/2” (30.1)

62Rescue Hardware FrameFrame Technical Data

November, 2004

12 GA. (2.6) REINFORCEMENT

PER TEMPLATE

PER TEMPLATE

PREPARATION:SIZE, DRILL AND TAP PER TEMPLATE

DOUBLE LIP LATCH STRIKE12 GA. (2.6) REINFORCEMENT

COVERBOX

2” (50.8) MINIMUM FACE REQUIRED FOR COVERBOX

7-3/4”(196.9)

PERTEMPLATE

FLOORLINE

CL

CL

L EMERGENCY STOP STRIKE SIDE

NOTE: CONTACT FACTORY ON AVAILABILITY WHEN USED WITH “C” TYPE COMPRESSION ANCHOR KD FRAMES.

Page 66: CURRIES Tech Data Frame Section.pdf5 Masonry Face Flush KD Frame Cased Opening Frame Technical Data March, 2015 VARIES 3” (76.2) MINIMUM 1” (25.4) 1-1/4” (31.8) 1-1/2” (30.1)

63Frame Pivots - Top, Bottom - Center Hung

Frame Technical DataDecember, 2006

TOP PIVOT7 GA. (4.5) REINF.

COVERBOX

MUDCAP

MUDCAP

CENTER HUNGCASED OPENING

TOP AND BOTTOM DOUBLE ACTING PIVOT

PREPARATION:SIZE, DRILL AND TAP PER TEMPLATE

BOTTOM PIVOT7 GA. (4.5) REINF.

TOP PIVOT7 GA. (4.5) REINF.1/8” INSET OR EDGE HUNG

COVERBOX

EDGE HUNGCASED OPENING

TOP AND BOTTOM SINGLE ACTING PIVOT

PREPARATION:SIZE, DRILL AND TAP PER TEMPLATE

BOTTOM PIVOT7 GA. (4.5) REINF.

EDGE HUNGNOTE: NOT ALL BOTTOM PIVOTS REQUIRE A FRAME PREP.

Page 67: CURRIES Tech Data Frame Section.pdf5 Masonry Face Flush KD Frame Cased Opening Frame Technical Data March, 2015 VARIES 3” (76.2) MINIMUM 1” (25.4) 1-1/4” (31.8) 1-1/2” (30.1)

64Frame Pivots - Top, Intermediate, Bottom - Single ActingFrame Technical Data

April, 2002

L

BOTTOM PIVOT7 GA. (4.5) REINF.

INTERMEDIATE PIVOT7 GA. (4.5) REINF.

TOP PIVOT7 GA. (4.5) REINF.

COVERBOX

MUDCAP

Page 68: CURRIES Tech Data Frame Section.pdf5 Masonry Face Flush KD Frame Cased Opening Frame Technical Data March, 2015 VARIES 3” (76.2) MINIMUM 1” (25.4) 1-1/4” (31.8) 1-1/2” (30.1)

65E1 Strike Reinf. (ANSI A115) 1-1/4” x 4-7/8”

Frame Technical DataApril, 2002

L

E2 Strike Reinf. (ANSI A115) 1-1/8” x 2-3/4”

L

16 GA. (1.4) REINF. COVER BOX1-1/16” (27) DEEP

1-1/4” (31.8)

4-7/8”(123.8)

40” (1016) TO STANDARD ON 1-3/4” (44.5) DOOR

CL

STANDARD STRIKEBACKSET 5/16” (7.9)

SCREW HOLES ARE EXTRUDED TO PROVIDE THREAD DEPTH EQUAL TO 12 GA. (2.6) PLATE

16 GA. (1.4) REINF. COVER BOX1” (25.4) DEEP

1-1/8” (28.6)

2-3/4”(69.9)

40” (1016) TO STANDARD ON 1-3/4” (44.5) DOOR

40-5/16” TO STANDARD ON 1-3/8” DOOR

CL

STANDARD STRIKEBACKSET 3/8” (9.5)

1-3/4” DOORBACKSET 3/16”

1-3/8” DOOR

SCREW HOLES ARE EXTRUDED TO PROVIDE THREAD DEPTH EQUAL TO 12 GA. (2.6) PLATE

SIZE AND TAP PER ANSI 115.2

SIZE AND TAP PER ANSI 115.1 AND 115.2

CL

Page 69: CURRIES Tech Data Frame Section.pdf5 Masonry Face Flush KD Frame Cased Opening Frame Technical Data March, 2015 VARIES 3” (76.2) MINIMUM 1” (25.4) 1-1/4” (31.8) 1-1/2” (30.1)

66E1B - Strike Reinf. 1-1/4” x 4-7/8” No LipFrame Technical Data

April, 2002

L

4-7/8”(123.8)

1-1/4”(31.8)

40” (1016) TOSTANDARD ON 1-3/4” (44.5) DOOR

CL

12 GA. (2.6)REINF. TABS

PER TEMPLATE

Page 70: CURRIES Tech Data Frame Section.pdf5 Masonry Face Flush KD Frame Cased Opening Frame Technical Data March, 2015 VARIES 3” (76.2) MINIMUM 1” (25.4) 1-1/4” (31.8) 1-1/2” (30.1)

67E3 Deadlock Strike Reinf. (ANSI/A115) 1-1/8” x 3-1/2”

Frame Technical DataApril, 2002

L

E4 Deadlock Strike Reinf. (ANSI/A115) 1-1/8” x 2-3/4” No Lip

L

16 GA. (1.4) REINF. COVER BOX1-1/16” (27) DEEP

1-1/8” (28.6)

3-1/2”(88.9)

48” (1219) TO STANDARD ON 1-3/4” (44.5) DOOR

CL

STRIKE BACKSET 3/8” (9.5)

12 GA. (2.6) REINF. TAB

SIZE AND TAP PER ANSI 115.5

16 GA. (1.4) REINF. COVER BOX1” (25.4) DEEP

1-1/8” (28.6)

2-3/4”(69.9)

48” (1219) TO STANDARD ON 1-3/4” (44.5) DOOR

CL

STRIKE BACKSET 3/8” (9.5)

SCREW HOLES ARE EXTRUDED TO PROVIDE THREAD DEPTH EQUAL TO 12 GA. (2.6) PLATE

SIZE AND TAP PER ANSI 115.4

Page 71: CURRIES Tech Data Frame Section.pdf5 Masonry Face Flush KD Frame Cased Opening Frame Technical Data March, 2015 VARIES 3” (76.2) MINIMUM 1” (25.4) 1-1/4” (31.8) 1-1/2” (30.1)

68EJ2 - Jamb Lock 2” (50.8) FaceFrame Technical Data

April, 2002

L

PERTEMPLATE

PERTEMPLATE

PERTEMPLATE

REINF. TABSPER TEMPLATE

PERTEMPLATE

2” (50.8) MIN. FACE3-1/16” (77.8) MIN. FACEON DRYWALL FRAME

40” (1016)

CL

Page 72: CURRIES Tech Data Frame Section.pdf5 Masonry Face Flush KD Frame Cased Opening Frame Technical Data March, 2015 VARIES 3” (76.2) MINIMUM 1” (25.4) 1-1/4” (31.8) 1-1/2” (30.1)

69EJ4, EJ8, EJ12 - Jamb Lock

Frame Technical DataApril, 2002

LPER

TEMPLATE

COVERPLATE

PERTEMPLATE

CUTOUTSPER

TEMPLATE

4” (101.6) STANDARD8” (203.2) STANDARD12” (304.8) STANDARD

STRIKE40” (1016)

CL

Page 73: CURRIES Tech Data Frame Section.pdf5 Masonry Face Flush KD Frame Cased Opening Frame Technical Data March, 2015 VARIES 3” (76.2) MINIMUM 1” (25.4) 1-1/4” (31.8) 1-1/2” (30.1)

70E30 - Strike - Pocket LockFrame Technical Data

July, 2003

L

PER TEMPLATE

PER TEMPLATE

7 GA. (4.5)REINF. TABS

40” (1016)

CL

Page 74: CURRIES Tech Data Frame Section.pdf5 Masonry Face Flush KD Frame Cased Opening Frame Technical Data March, 2015 VARIES 3” (76.2) MINIMUM 1” (25.4) 1-1/4” (31.8) 1-1/2” (30.1)

71MAG - Magnetic Lock

Frame Technical DataJuly, 2003

L

PER TEMPLATE

PER TEMPLATE

REINF. TABSPER TEMPLATE

Page 75: CURRIES Tech Data Frame Section.pdf5 Masonry Face Flush KD Frame Cased Opening Frame Technical Data March, 2015 VARIES 3” (76.2) MINIMUM 1” (25.4) 1-1/4” (31.8) 1-1/2” (30.1)

72E5 Rim Vertical Rod Surface Strike Reinf.Frame Technical Data

April, 2002

L

G20 Vertical Rod Exit Mortise Strike Preparation

L

1-3/4” (44.5)

12 GA. (2.6)

10” (254)

CL

12 GA. (2.6) REINF. WELDEDTO INSIDE OF SOFFIT TIGHTTO DOOR RABBET STOP

G20 PREPARED FOR MORTISE STRIKES PERTEMPLATE OF HARDWARE MANUFACTURER

SPECIFY EXIT DEVICE AND STRIKE BEING USED WHEN ORDERING

E5 REINFORCING IS LOCATED ON CENTERLINE OF HEAD FOR PAIR FRAMESAND ADJACENT TO STRIKE JAMB ON SINGLE SWING FRAMES.

DOOR RABBET

HEADS

DOOR

Page 76: CURRIES Tech Data Frame Section.pdf5 Masonry Face Flush KD Frame Cased Opening Frame Technical Data March, 2015 VARIES 3” (76.2) MINIMUM 1” (25.4) 1-1/4” (31.8) 1-1/2” (30.1)

73E8 Rim Exit Reinforcement

Frame Technical DataApril, 2002

L

12 GA. (2.6) REINF. WELDED TO INSIDE OF SOFFIT TIGHT TO DOOR RABBET STOP

41” (1041.4) TO STANDARD

CL

8” (203.2)

1-1/4” (31.8)*

12 GA. (2.6)

DOOR

* THE REINFORCEMENT WIDTH WILL BE EQUAL TO THE SOFFIT WIDTH WHEN LESS THAN 1-1/4” (31.8). CUSTOMER SHOULD VERIFY HARDWARE COMPATIBILITY BEFORE ORDERING NARROW SOFFITS.

Page 77: CURRIES Tech Data Frame Section.pdf5 Masonry Face Flush KD Frame Cased Opening Frame Technical Data March, 2015 VARIES 3” (76.2) MINIMUM 1” (25.4) 1-1/4” (31.8) 1-1/2” (30.1)

74E9 Electric StrikesFrame Technical Data

April, 2002

L

NOTE: FIRE RATED FRAMES INCORPORATING AN ELECTRIC STRIKE WITH A COVERBOX, REQUIRE THAT THE WALL BOARD PENETRATE THE THROAT OF THE FRAME BY 1/2” (12.7) MINIMUM. ELECTRIC STRIKE MUST BE LISTED FOR USE WITH FIRE RATED OPENINGS.

16 GA. (1.4) REMOVABLE COVER BOX

CONFIGURATION OF CUTOUT VARIESPER HARDWARE MFG. TEMPLATE

SPECIFY STRIKE BEING USED WHEN ORDERING

STRIKECL

VERTICAL LOCATION OF ELECTRIC STRIKE WILL VARY WITH THE HARDWARE MANUFACTURER, WHEN ORDERING FRAMES PREPARED FOR AN ELECTRIC STRIKE, SPECIFY THE TYPE OF LOCK BEING USED ALONG WITH CENTERLINE DIMENSION REQUIRED OF THE LOCK.

7/8” (22.2) DIA.KNOCKOUT FOR ELECTRIC CONNECTOR

12 GA. (2.6) REINF. TAB

Page 78: CURRIES Tech Data Frame Section.pdf5 Masonry Face Flush KD Frame Cased Opening Frame Technical Data March, 2015 VARIES 3” (76.2) MINIMUM 1” (25.4) 1-1/4” (31.8) 1-1/2” (30.1)

75Conduit - Coverbox Clearance Dimensions

Frame Technical DataSeptember, 2005

L1-1/8” (28.6) OR 7/8” (22.2) DIA.KNOCKOUT

RABBET CL

FACE

END VIEW OF FRAME AND COVERBOX

REMOVABLE COVER

AS REQUIRED

CL

CL

DEPTH

WIDTH

COVERBOX

1/2” (12.7) CONDUIT CONNECTOR LOCKNUTBY OTHERS

1/2” (12.7) CONDUIT CONNECTORBY OTHERS

SIDE VIEW OF COVERBOX

LOCKNUT

1-1/8” (28.6)*

MINIMUM INSIDE DEPTH DIMENSION REQUIREDTO ACCOMODATE THE LOCKNUT.

* 1-1/2” (38.1) FOR 3/4” CONDUIT CONNECTOR

1/2” CONDUIT CONNECTORS ARE FOR 7/8” KNOCKOUT / 1-1/8” HIGH COVERBOX3/4” CONDUIT CONNECTORS ARE FOR 1-1/8” KNOCKOUT / 1-1/2” HIGH COVERBOX

DOUBLE KNOCKOUT FOR 1/2” AND 3/4”

CONDUIT CONNECTORS ARE FOR THE 1-1/2” HIGH COVER BOX ONLY

1-1/8” HIGH COVERBOX HAS 7/8” KNOCKOUT ONLY FOR 1/2” CONDUIT CONNECTOR

1/2”(12.7)

3/4”(19.1)

Page 79: CURRIES Tech Data Frame Section.pdf5 Masonry Face Flush KD Frame Cased Opening Frame Technical Data March, 2015 VARIES 3” (76.2) MINIMUM 1” (25.4) 1-1/4” (31.8) 1-1/2” (30.1)

76Conduit Preparation (RW-3)Frame Technical Data

March, 2013

L

6.00” + 1.00”

TOP

JAMB MULLION

HEAD MULLION

LOCK SIDE

6.00” + 1.00”

1/2” EMT CONDUITFACTORY INSTALLED WHEN REQUESTED(MULLION ONLY)

REQUIRED FOR POWER TRANSFER AND ELECTRIC STRIKES

Page 80: CURRIES Tech Data Frame Section.pdf5 Masonry Face Flush KD Frame Cased Opening Frame Technical Data March, 2015 VARIES 3” (76.2) MINIMUM 1” (25.4) 1-1/4” (31.8) 1-1/2” (30.1)

77E10 Standard Mtg. 14 ga. Closer Reinforcement

Frame Technical DataJanuary, 2005

L

E11 Parallel Arm Mtg. 14 ga. Closer Reinf.

L

14 GA. (1.9)

1-3/4” (44.5)10” (254)

7” (177.8)

14 GA. (1.9)

1-1/4” (31.8)

20” (508)

14 GA. (1.9) REINF. WELDEDTO INSIDE OF SOFFIT TIGHTTO DOOR RABBET STOP

DOOR

HINGE SIDE

HINGE SIDEDOOR

NOTE: WHEN SOFFIT WIDTH IS LESS THAN 1” - E16 WILL BE USED

Page 81: CURRIES Tech Data Frame Section.pdf5 Masonry Face Flush KD Frame Cased Opening Frame Technical Data March, 2015 VARIES 3” (76.2) MINIMUM 1” (25.4) 1-1/4” (31.8) 1-1/2” (30.1)

78E12 Top Jamb Mtg. 14 ga. Closer Reinf.Frame Technical Data

November, 2004

L14 GA. (1.9)

2” (50.8)

16” (406.4)

1-3/4” (44.5)2-3/4” (69.9)

DOOR

HINGE SIDE

Page 82: CURRIES Tech Data Frame Section.pdf5 Masonry Face Flush KD Frame Cased Opening Frame Technical Data March, 2015 VARIES 3” (76.2) MINIMUM 1” (25.4) 1-1/4” (31.8) 1-1/2” (30.1)

79E13 Corner Bkt. Mtg. 14 ga. Closer Reinf.

Frame Technical DataJanuary, 2005

L

Double Egress Frame Closer Reinforcements

L

14 GA. (1.9)

1-1/4” (31.8)

8” (203.2)

8” (203.2)

14 GA. (1.9) REINF. WELDEDTO INSIDE OF SOFFIT TIGHTTO DOOR RABBET STOP

E11 ------------------PARALLEL ARM MOUNTING -------------------------14 GA. (1.9) 20” (508) LONG

E10 ------------------REGULAR MOUNTING -------------------------------14 GA. (1.9) 10” (254) LONGE12 ------------------TOP JAMB MOUNTING ------------------------------14 GA. (1.9) 16” (406.4) LONG

E17A -----------------FULL SLEEVE ----------------------------------------14 GA. (1.9) REGULAR, TOP JAMB 16” (406.4) LONG PARALLEL ARM MOUNTINGS

E18 ------------------HALF SLEEVE ---------------------------------------14 GA. (1.9) REGULAR AND 16” (406.4) LONG PARALLEL ARM MOUNTINGS

REGULARTOP

JAMB

DOOR

HINGE SIDE

Page 83: CURRIES Tech Data Frame Section.pdf5 Masonry Face Flush KD Frame Cased Opening Frame Technical Data March, 2015 VARIES 3” (76.2) MINIMUM 1” (25.4) 1-1/4” (31.8) 1-1/2” (30.1)

80E15 Closer Reinf.Frame Technical Data

October, 2014

L

E16 Double Parallel Arm 14 ga. Closer Reinf.

L

14 GA. (1.9)

1-3/4” (44.45)24” (609.6)

14 GA. (1.9)

VARIES PER SOFFIT WIDTHUP TO 1-5/8” (41.3)

1-1/4” (31.8)

14 GA. (1.9) ADDITIONAL REINF. ADDEDWHEN SOFFIT IS UNDER 2” (50.8) IN WIDTH

20” (508)

20” (508)

14 GA. (1.9) ADDITIONAL REINF. WELDED TO INSIDE OF SOFFIT TIGHT TO DOOR RABBET STOP

DOOR

DOOR

HINGE SIDE

HINGE SIDE

1/2” (12.7)

Page 84: CURRIES Tech Data Frame Section.pdf5 Masonry Face Flush KD Frame Cased Opening Frame Technical Data March, 2015 VARIES 3” (76.2) MINIMUM 1” (25.4) 1-1/4” (31.8) 1-1/2” (30.1)

81E17 14 ga. Full Sleeve Closer Reinforcement

Frame Technical DataApril, 2015

L

E18 14 ga. Formed Half Sleeve Closer Reinf.

L

14 GA. (1.9)

1-3/4” (44.5)

16” (406.4)

1” (25.4) MIN.

1-3/4” (44.5)

14 GA. (1.9)

2-3/8” (60.3)

1” (25.4) MIN.

1-3/4” (44.5)

HINGEJAMBLINE

16” (406.4)

NOTE: SPECIAL PROFILE REINFORCEMENT REQUIRED WHEN CLOSER IS MOUNTED TO FRAME FACE GREATER THAN 2"

16” (406.4)14 GA. (1.9)

1-3/4” (44.5)

1-1/4” (31.8) NOTE 1 3/4” (19.1) NOTE 2

5/8” (15.9)

1-15/16” (49.2) FOR 1-3/4” (44.5) DOOROR

1-9/16” (39.7) FOR 1-3/8” (34.9) DOOR

NOTE:1) 1-1/2” (38.1) MINIMUM SOFFIT REQ’D2) 1” (25.4) MINIMUM SOFFIT REQ’D

NOTE: SPECIAL PROFILE REINFORCEMENT REQUIRED WHEN CLOSER IS MOUNTED TO FRAME FACE GREATER THAN 2”

DOORHINGE SIDE

Page 85: CURRIES Tech Data Frame Section.pdf5 Masonry Face Flush KD Frame Cased Opening Frame Technical Data March, 2015 VARIES 3” (76.2) MINIMUM 1” (25.4) 1-1/4” (31.8) 1-1/2” (30.1)

82EPT - Electronic Power TransferFrame Technical Data

May, 2011

L

TOP HINGE

PER TEMPLATE

*

12 GA. (2.6)REINFORCINGTABS

PERTEMPLATE

PER TEMPLATE

* LOCATION PER TEMPLATE. IF NO LOCATION ON TEMPLATE, THEN LOCATION MUST BE SPECIFIED WITH ORDER. THE QUANTITY OF HINGES MAY REQUIRE COORDINATION OF LOCATION WITH DOOR, (EX. 4 HINGES ON A 7’0”). WOOD DOORS MAY REQUIRE OTHER LOCATIONS

Page 86: CURRIES Tech Data Frame Section.pdf5 Masonry Face Flush KD Frame Cased Opening Frame Technical Data March, 2015 VARIES 3” (76.2) MINIMUM 1” (25.4) 1-1/4” (31.8) 1-1/2” (30.1)

83G21 - G22 Removable Hardware Mullion

Frame Technical DataApril, 2002

L

H3A - H3B Surface Bolt Preparation

L

MULLION TOP BRACKET MOUNTING SCREWS TO BE DRILLED ANDTAPPED IN FIELD BY HARDWARE INSTALLER.

G21 PLATE REINFORCEMENTUSED WHEN SOFFIT IS 3” (76.2) WIDE OR GREATER.

G21

G22 PLATE REINFORCEMENTUSED WHEN SOFFIT IS LESS THAN3” (76.2).

G22

5/8” (15.9) C.R.S. FILLER BLOCK ISFURNISHED WHEN SOFFIT WIDTH IS TOONARROW TO APPLY HARDWARE TO SOFFIT

PLUG WELDED ONLY

WELDEDDOORDOOR HARDWARE MULLIONASSEMBLY

H3B-12 GA. (2.6)

H3A-12 GA. (2.6)

1-3/4” (44.5)

1-3/4” (44.5)

10” (254)

10” (254)

H3A FACE PREP.12 GA. (2.6) REINF. WELDEDTO INSIDE OF FRAME FACE

CLHEAD AND REINFORCEMENT

H3B SOFFIT PREP.12 GA. (2.6) REINF. WELDEDTO INSIDE OF SOFFIT TIGHT

TO DOOR RABBET STOP

NOTE: WHEN ORDERING SPECIFY EITHER H3A OR H3B REINFORCING

12 GA. (2.6)

DOOR

OF DOORS

DOOR SIDE

Page 87: CURRIES Tech Data Frame Section.pdf5 Masonry Face Flush KD Frame Cased Opening Frame Technical Data March, 2015 VARIES 3” (76.2) MINIMUM 1” (25.4) 1-1/4” (31.8) 1-1/2” (30.1)

84G24 Coordinator ReinforcementFrame Technical Data

CL - Closer Reinforcement Per Template

October, 2014

L12 GA. (2.6)

1-3/8” (34.9) 10” (254)

CL

12 GA. (2.6) REINF. WELDEDTO INSIDE OF FRAME FACE.

DOOR

OF DOORSCL

OF PAIR

2” (51)

14 GA. (1.9)

*PER TEMPLATE

*PER TEMPLATE

DOOR

* SPECIFY MANUFACTURER AND MODEL NUMBER WHEN ORDERING ADVISE POWER SOURCE LOCATION IF REQUIRED

HINGE SIDE

Page 88: CURRIES Tech Data Frame Section.pdf5 Masonry Face Flush KD Frame Cased Opening Frame Technical Data March, 2015 VARIES 3” (76.2) MINIMUM 1” (25.4) 1-1/4” (31.8) 1-1/2” (30.1)

85Grout Hole

Frame Technical DataSeptember, 2008

L

RABBET PREPARATION(DOOR RABBET STANDARD)

FACE PREPARATION(DOOR FACE STANDARD)

12 GA. (2.6) REINF. PLATE1-3/8” (35) DIA.HOLE IN REINF. PLATE

12 GA. (2.6) REINF. PLATE1-3/8” (35) DIA.HOLE IN REINF. PLATE

FILLER PLATESAME GAUGE AS FRAME.SHIPPED LOOSE.1-3/8” X 1-3/8”(35 X 35)

FILLER PLATESAME GAUGE AS FRAME.SHIPPED LOOSE.1-3/8” X 1-3/8”(35 X 35)

Page 89: CURRIES Tech Data Frame Section.pdf5 Masonry Face Flush KD Frame Cased Opening Frame Technical Data March, 2015 VARIES 3” (76.2) MINIMUM 1” (25.4) 1-1/4” (31.8) 1-1/2” (30.1)

86H1 Flush Bolt ReinforcementFrame Technical Data

April, 2002

L

H2 Flush Bolt Prep. and Reinf. (ANSI)

L

1-1/4” (31.8)12 GA. (2.6)

8” (203.2)

OF OPENING AND REINFORCEMENTCL

12 GA. (2.6) REINF. WELDED IN CENTER OF DOOR RABBETCL

12 GA. (2.6) 16 GA. (1.4) REINF. COVER BOX1-1/16” (27) DEEP

2-1/4” (57.2)

CL

CL

OF DOORS

CUTOUT

INACTIVE DOOR

13/16” (20.6)

15/16” (23.8)

15/32” (11.9) BACKSET

SIZE AND TAP PER ANSI 115.4

DOOR

DOOR

Page 90: CURRIES Tech Data Frame Section.pdf5 Masonry Face Flush KD Frame Cased Opening Frame Technical Data March, 2015 VARIES 3” (76.2) MINIMUM 1” (25.4) 1-1/4” (31.8) 1-1/2” (30.1)

87H4 Auto Flush BoltFrame Technical Data

April, 2002

L

H5 Non-handed Flush Bolt

L

PREPARATION FOR AUTOMATIC FLUSH BOLT IS PER HARDWARE MANUFACTURER’S TEMPLATE.

PLEASE SPECIFY MANUFACTURER AND MODEL NUMBER WHEN ORDERING.

LABELED IF HARDWARE IS APPROVED AND PREPPED TO TEMPLATE.

3-7/8” (98.4)

12 GA. (2.6) REINF.

15/16” (23.8)

OF DOORSCL

NOTE: STRIKE PLATE INSTALLED FILLER PLATE MAY BE PURCHASED SEPARATELY IN PACKAGES OF 50 PIECES WITH SCREWS.

3-1/4” (82.6) 16 GA. (1.4) GALV. FILLER PLATEPART #CF004637

16 GA. (1.4) GALV. FILLER PLATEPART #CF001257

C’ SUNK FOR #8-32 X 5/8” (15.9)FLAT HEAD HARDWARE SCREW

HEADCL

CL

7/8” (22.2)

CL

5/8” (15.9)1-1/8” (28.6)

Page 91: CURRIES Tech Data Frame Section.pdf5 Masonry Face Flush KD Frame Cased Opening Frame Technical Data March, 2015 VARIES 3” (76.2) MINIMUM 1” (25.4) 1-1/4” (31.8) 1-1/2” (30.1)

88Electric Magnetic Door Position SwitchFrame Technical Data

April, 2002

L

16 GA. (1.4) GROUT GUARD COVERBOX ENDS SPOT WELDED OVER PREPARATION.

ELECTRICAL CONDUITKNOCKOUT AS REQUIRED.

#8 PAN HEAD SCREW.

CUTOUT SIZE AND LOCATION PER HARDWARE TEMPLATE

12 GA. (2.6)REINFORCING TAB.

NOTE: JUNCTION BOXES ARE NOT CAULKED AT THE FACTORY. TO BE FIELD CAULKED BY INSTALLA-TION CONTRACTOR.

Page 92: CURRIES Tech Data Frame Section.pdf5 Masonry Face Flush KD Frame Cased Opening Frame Technical Data March, 2015 VARIES 3” (76.2) MINIMUM 1” (25.4) 1-1/4” (31.8) 1-1/2” (30.1)

89Electric Fully-Concealed Door Position Switch

Frame Technical DataApril, 2002

L

16 GA. (1.4) GROUT GUARD COVERBOX SPOT WELDED OVER PREPARATION

ELECTRICAL CONDUITKNOCKOUT AS REQUIRED

#8 PAN HEAD SCREW.

CUTOUT SIZE AND LOCATION PER HARDWARE TEMPLATE

12 GA. (2.6)REINFORCING TAB

NOTE: JUNCTION BOXES ARE NOT CAULKED AT THE FACTORY. TO BE FIELD CAULKED BY INSTALLA-TION CONTRACTOR.

Page 93: CURRIES Tech Data Frame Section.pdf5 Masonry Face Flush KD Frame Cased Opening Frame Technical Data March, 2015 VARIES 3” (76.2) MINIMUM 1” (25.4) 1-1/4” (31.8) 1-1/2” (30.1)

90Cabinet Jamb FrameFrame Technical Data

April, 2002

L

DOOR OPENING

ROUGH OPENING

DOOR OPENING

ROUGH OPENING

NOT U.L. LISTEDS.M.W. JAMB SECTIONBUCKS SHIP LOOSE SQUARE BUTT ENDFIELD ASSEMBLED WITH SCREWSOR WELDED

1-3/4” (44.5)1” (25.4)

1-7/8” (47.6)

ROUGH OPENING DETERMINESTHE LENGTH OF THE BUCK LEGS

MACH SCREW#8 X 1/2” PAN HEAD

7/8” (22.2)

Page 94: CURRIES Tech Data Frame Section.pdf5 Masonry Face Flush KD Frame Cased Opening Frame Technical Data March, 2015 VARIES 3” (76.2) MINIMUM 1” (25.4) 1-1/4” (31.8) 1-1/2” (30.1)

91Rough Buck FrameFrame Technical Data

February, 2011

L2-1/2” (63.5) MIN.

3” (76.2) MAX.

2-1/2” (63.5) MIN. TYP.3” (76.2) MAX. TYP.

DOOROPENING

ROUGHOPENING

DOOR OPENING

ROUGH OPENING

U.L. LISTED ROUGH BUCK FRAMESBUCKS SHIPPED LOOSE SQUARE BUTT END.FULLY PREPARED FOR INSTALLATIONWITH MOUNTING HOLES.

FINISH BUCK16 GA. (1.4) OR 14 GA. (1.9)

HINGE OR STRIKE REINF.1/4-20 NC X 1-1/4”FLAT HEAD MACH SCREW

2” (50.8)

2” (50.8)

#8 x 1/2”PAN HEADMACH SCREW

12 GA. (2.6) REINF. SUB-CHANNELU.L. FRAME ONLY

SUB-BUCK14 GA. (1.9) ONLY FOR LABEL

2” (50.8)

2” (50.8)

CORNER DETAILCORNER IS NOTCHED FOR FIELD INSTALLATIONFINISH BUCK CAN NOT BE WELDED PRIOR TOINSTALLATION.

NOTE: LABEL FRAMES FURNISHED WITH ATTACHING SCREWS AND BOLTS FOR ASSEMBLY

Page 95: CURRIES Tech Data Frame Section.pdf5 Masonry Face Flush KD Frame Cased Opening Frame Technical Data March, 2015 VARIES 3” (76.2) MINIMUM 1” (25.4) 1-1/4” (31.8) 1-1/2” (30.1)

92Curriseal Frame Flush KD - WM - WGFrame Technical Data

September, 2003

L

K.D. “M” TYPE FLUSH GAUGE - 18 GA. (1.2), 16 GA. (2.4), 14 GA. (1.9) JAMB DEPTHS:DOUBLE RABBET (WM) 5-1/4” (133.4) - 14” (355.6) (1/8” (3.2) INCREMENTS)SINGLE RABBET (WG) 4-1/8” (104.8) - 14” (355.6) (1/8” (3.2) INCREMENTS) AVAILABLE WITH 4” (101.6) FACE HEADS DOUBLE RABBET AVAILABLE IN COMMUNICATING FRAMES WITH A 6-1/2” (165.1) MIN. JAMB DEPTH

HARDWARE RESTRICTIONSNOT RECOMMENDED- CLOSERS WITH REMOVABLE STOPS- VERTICAL ROD DEVICES WITH STRIKES MORTISED IN THE STOP- STOP ACTIVATED VERTICAL ROD DEVICES

NOTE: SOFFIT MOUNTED SURFACE HARDWARE MAY REQUIRE+_ 1/8” (3.2) ADJUSTMENT OF MOUNTING HOLES TO ACCOMODATEWEATHERSTRIP AND ENSURE NORMAL DOOR OPERATION.

CURRISEALACTUAL SIZE

COLOR: DARK BROWN

2-1/8”(54.0)

1-9/16” (39.7)

1-15/16” (49.2)ORVARIES

5/8” (15.9)ONLY

1” (25.4)1-1/4” (31.8)1-1/2” (38.1)1-3/4” (44.5)

2” (50.8)

1/2” (12.7)*

2-5/8” (66.7)ONLYWG

WM/WG

1-3/4” DOOR(44.5)

1/4” (6.3)

1/8” (3.2)

CURRISEAL FRAME IS DESIGNED FOR USE WITH THE CURRISEAL ONLY

5-3/4” (146.1) JAMB DEPTH AVAILABLE WITH 7/16” (11.1) RETURNSTO PROVIDE A 4-7/8” (123.8) THROAT OPENING

*KD CORNER

Page 96: CURRIES Tech Data Frame Section.pdf5 Masonry Face Flush KD Frame Cased Opening Frame Technical Data March, 2015 VARIES 3” (76.2) MINIMUM 1” (25.4) 1-1/4” (31.8) 1-1/2” (30.1)

93Curriseal Frame KD Drywall - WC - WCG

Frame Technical DataSeptember, 2003

L

K.D. “C” TYPE DRYWALL GAUGE - 18 GA. (1.2), 16 GA. (2.4), 14 GA. (1.9) JAMB DEPTHS:DOUBLE RABBET (WC) 5-1/4” (133.4) - 14” (355.6) (1/8” (3.2) INCREMENTS)SINGLE RABBET (WCG) 4-1/8” (104.8) - 14” (355.6) (1/8” (3.2) INCREMENTS) DOUBLE RABBET AVAILABLE IN COMMUNICATING FRAMES WITH A 6-1/2” (165.1) MIN. JAMB DEPTH

HARDWARE RESTRICTIONSNOT RECOMMENDED- CLOSERS WITH REMOVABLE STOPS- VERTICAL ROD DEVICES WITH STRIKES MORTISED IN THE STOP- STOP ACTIVATED VERTICAL ROD DEVICES

NOTE: SOFFIT MOUNTED SURFACE HARDWARE MAY REQUIRE+_ 1/8” (3.2) ADJUSTMENT OF MOUNTING HOLES TO ACCOMODATEWEATHERSTRIP AND ENSURE NORMAL DOOR OPERATION.

CURRISEALACTUAL SIZE

COLOR: DARK BROWN

2-1/8”(54.0)

1-9/16” (39.7)

1-15/16” (49.2)ORVARIES

5/8” (15.9)ONLY

1-1/2” (38.1)1-3/4” (44.5)

2” (50.8)

1/2” (12.7)

2-5/8” (66.7)ONLYWC/WCG

1-3/4” DOOR(44.5)

1/4” (6.3)

1/8” (3.2)

CURRISEAL FRAME IS DESIGNED FOR USE WITH THE CURRISEAL ONLY

KD CORNER

3/8” (9.5)

Page 97: CURRIES Tech Data Frame Section.pdf5 Masonry Face Flush KD Frame Cased Opening Frame Technical Data March, 2015 VARIES 3” (76.2) MINIMUM 1” (25.4) 1-1/4” (31.8) 1-1/2” (30.1)

94NotesFrame Technical Data

January, 2007

Page 98: CURRIES Tech Data Frame Section.pdf5 Masonry Face Flush KD Frame Cased Opening Frame Technical Data March, 2015 VARIES 3” (76.2) MINIMUM 1” (25.4) 1-1/4” (31.8) 1-1/2” (30.1)

95Notes

Frame Technical DataJanuary, 2007

Page 99: CURRIES Tech Data Frame Section.pdf5 Masonry Face Flush KD Frame Cased Opening Frame Technical Data March, 2015 VARIES 3” (76.2) MINIMUM 1” (25.4) 1-1/4” (31.8) 1-1/2” (30.1)

96Communicating FrameFrame Technical Data

April, 2002

L

NOTE:U.L. AND W.H.I. LABELED FRAMES MAY BE PROVIDEDWITH COMPRESSION TYPE ANCHORING SYSTEM.

“M” PROFILE FLUSH K.D. “C” & “CM” PROFILE DRYWALL

EQUAL RABBET1-15/16” (49.2) FOR 1-3/4” (44.5) DOORS4-7/8” (117.5) THRU 14” (355.6) JAMB DEPTH

UNEQUAL RABBET1-15/16” (49.2) X 1-9/16” (39.7) FOR1-3/4” (44.5) X 1-3/8” (34.9) DOORS4-1/2” (114.3) THRU 14” (355.6) JAMB DEPTH

EQUAL RABBET1-9/16” (39.7) FOR 1-3/8” (34.9) DOORS4-7/8” (117.5) THRU 14” (355.6) JAMB DEPTH

EQUAL RABBET1-9/16” (39.7) FOR 1-3/8” (34.9) DOORS4-7/8” (117.5) THRU 14” (355.6) JAMB DEPTH

UNEQUAL RABBET1-15/16” (49.2) X 1-9/16” (39.7) FOR1-3/4” (44.5) X 1-3/8” (34.9) DOORS4-1/2” (114.3) THRU 14” (355.6) JAMB DEPTH

EQUAL RABBET1-15/16” (49.2) FOR 1-3/4” (44.5) DOORS4-7/8” (117.5) THRU 14” (355.6) JAMB DEPTH

Page 100: CURRIES Tech Data Frame Section.pdf5 Masonry Face Flush KD Frame Cased Opening Frame Technical Data March, 2015 VARIES 3” (76.2) MINIMUM 1” (25.4) 1-1/4” (31.8) 1-1/2” (30.1)

97Pocket Door Frame - Standard 1-3/8” or 1-3/4” Door Single

Frame Technical DataMarch, 2011

2”(50.8)

2” (50.8)FINISH OPENING

**

1

32

NOMINAL DOOR

OPENING HEIGHT

*

2” (50.8)

NOMINAL DOOR

OPENING HEIGHT

*

5/8” (15.9)

5/8” (15.9)

DOOR

1

VERIFY HARDWARE ADAPTABILITYFRAME MUST BE INSTALLED AND

HARDWARE TRACK MUST BE HUNG PRIOR TO FINISH WALL STUDS BEING SET.

AVAILABLE IN 18 GA. (1.2) AND 16 GA. (1.4) STEEL.

L

2” (50.8)

2” (50.8)FINISH OPENING WIDTH

**1/2” (12.7)

1/2” (12.7)

2

5/8” (15.9)

2” POCKET(50.8)

1-3/4” (44.5) DOOR 3

NOTE: 1-3/8” (34.9) DOORFRAME HAS 1-5/8” (41.3) POCKET

EQUAL

EQUAL

1” (25.4)DOOR

POCKET

1/2” (12.7)

1/2” (12.7)

4” (101.6) MIN.12” (304.8) MAX.

ANCHOR P110USED FOR METAL STUDOR WOOD STUD WALL

1” (25.4)

4-1/4” (107.9)

VARIES WITH JAMB DEPTH & STUD SIZE.SPECIFY STUD SIZE WHEN ORDERING.

FRAME FINISHED OPENING WIDTH SHOULD BE ORDERED 1” LESS THAN DESIRED NET DOOR SIZE.EXAMPLE: A 3’0” (914.4) POCKET FRAME WILLHAVE FINISH OPENING WIDTH OF 2’11” (889).THIS ALLOWS THE USE OF STANDARD DOOR WIDTHS.

FINISH OPENING HEIGHT IS NOMINAL DOOR HEIGHTUSING CURRIES STANDARD DOOR UNDERCUT.

**

*

TRACK HARDWARE & REINFORCEMENT PROVIDED BY OTHERS

Page 101: CURRIES Tech Data Frame Section.pdf5 Masonry Face Flush KD Frame Cased Opening Frame Technical Data March, 2015 VARIES 3” (76.2) MINIMUM 1” (25.4) 1-1/4” (31.8) 1-1/2” (30.1)

98Pocket Door Frame-Saw Mitered-Welded for 1-3/4” or 1-3/8” DoorsFrame Technical Data

March, 2011

1. MITER HEAD AND JAMB AT 45˚2. CLAMP AND TACK WELD AT BACKBEND AND FACE.3. CONTINUOUS WELD INSIDE SEAM.4. GRIND AND FINISH OUTSIDE SURFACES.

SPLIT HEAD AND HINGE JAMB

A

B

C

A

B

C

A

B

C

STRIKE JAMB

FLOOR ANCHORP165

2 PC 2 PML

FLOOR ANCHOR WILL BE WELDED TO FACES OF FRAME WHEN FACTORY WELDED. MUST BE ATTACHED TO FRAME FACES WHEN FRAME IS WELDED BY OTHERS.

Page 102: CURRIES Tech Data Frame Section.pdf5 Masonry Face Flush KD Frame Cased Opening Frame Technical Data March, 2015 VARIES 3” (76.2) MINIMUM 1” (25.4) 1-1/4” (31.8) 1-1/2” (30.1)

99Stainless Steel Slip-On Type Spats

Frame Technical DataSeptember, 2013

L

STAINLESS STEEL SLIP-ON SPATSTANDARD PROFILE IS MANUFACTUREDTO FIT OVER JAMB PROFILE.SPECIFY JAMB PROFILE WHEN ORDERING

18 GA. (1.1) #304 STAINLESS STEEL#4 SATIN GRAIN FINISH

NOTE:SPATS ARE LABELED UP TOA HEIGHT OF 8” (203.2)

4” (101.6)STANDARD

4” (101.6)STANDARD

HOSPITAL TYPE SPATSTANDARD PROFILE IS MANUFACTURED

TO FIT OVER JAMB BELOW STOP.SPECIFY JAMB PROFILE WHEN ORDERING

18 GA. (1.1) #304 STAINLESS STEEL#4 SATIN GRAIN FINISH

NOTE:HOSPITAL TYPE SPATS

ARE LABELED UP TOA HEIGHT OF 6” (152.4)

Page 103: CURRIES Tech Data Frame Section.pdf5 Masonry Face Flush KD Frame Cased Opening Frame Technical Data March, 2015 VARIES 3” (76.2) MINIMUM 1” (25.4) 1-1/4” (31.8) 1-1/2” (30.1)

100Hospital StopFrame Technical Data

April, 2002

ANCHOR PART NUMBER: P0079FILLER & BACKING PLATEUSED ON FRAMES NOT REQUIRING A FOOT CLIP ORFRAMES THAT HAVE SOME OTHER BASE ANCHORING METHOD.

ANCHOR PART NUMBER: P0077FILLER & COMBINATION BACKING PLATE-FOOT CLIPUSED ON FRAMES REQUIRING A FOOT CLIP.

NOTE: FOOTCLIP REQUIRED FOR LABEL

VARIES

STOP CUT AWAY ON 45˚ ANGLE TO RECEIVE FILLER

4” (101.6)STANDARD

FILLER SIZES AVAILABLEUP TO 9” (228.6) HIGH

CHOOSE EITHER P0077 OR P0079 BACKING PLATE.WELD BACKING PLATE BEHIND CUTOUT.WELD FILLER INTO CUTOUT, GRIND, FILL AND FINISH SMOOTH.

4” (101.6) STANDARDFROM FACTORY *

HEIGHTS AVAILABLE UP TO 9” (228.6) HIGH6” (152.4) HIGH MAXIMUM ON FIRE RATED FRAMESFACTORY INSTALLED OR BY SECOND LOCATION SHOP

*

45˚ CUT

L

Page 104: CURRIES Tech Data Frame Section.pdf5 Masonry Face Flush KD Frame Cased Opening Frame Technical Data March, 2015 VARIES 3” (76.2) MINIMUM 1” (25.4) 1-1/4” (31.8) 1-1/2” (30.1)

101Thermal Break Frame KD Flush Profile

Frame Technical DataDecember, 2016

L14 GA. (1.9) AND 16 GA. (1.4) GALVANEALED STEEL5/8” (15.9) HIGH STOP ONLYKD ONLY (FACE WELDED ONLY)MAXIMUM KD LENGTH - 118” JAMB, 116” HEADPUNCH FOR SILENCERS NOT AVAILABLE

ANCHOR OPTIONS: MASONRY T WIRE ANCHOR SPLIT BASE ANCHOR SPLIT WOODSTUD ANCHOR PIPE SPACER ANCHOR

2” (50.8) OR 4” (101.6) FACE HEAD

DOOR RABBET

THERMAL BREAK

5-3/4” (146.1)THRU 12-3/4” (323.9)

JAMB DEPTH

THERMAL BREAK

DOORRABBET

2” (50.8)FACE

Page 105: CURRIES Tech Data Frame Section.pdf5 Masonry Face Flush KD Frame Cased Opening Frame Technical Data March, 2015 VARIES 3” (76.2) MINIMUM 1” (25.4) 1-1/4” (31.8) 1-1/2” (30.1)

102Thermal Break Frame CCW Stick ComponentsFrame Technical Data

December, 2016

L16 GA. (1.4) AND 14 GA. (1.9) GALVANEALED STEEL ONLY5/8” (15.9) HIGH STOPS ONLY BUTT END JOINTS ONLYNOT LABELED

MULLION - 16 GA. (1.4) AND 14 GA. (1.9) 2” (50.8) FACE ONLY. PUNCH FOR SILENCERS NOT AVAILABLE.

5-3/4” (146.1)THRU 12-3/4” (323.9)

JAMB DEPTH

2” (50.8) FACE

THERMAL BREAK

THERMAL BREAK2” (50.8)

ONLY

DOOR RABBET

DOOR RABBET

Page 106: CURRIES Tech Data Frame Section.pdf5 Masonry Face Flush KD Frame Cased Opening Frame Technical Data March, 2015 VARIES 3” (76.2) MINIMUM 1” (25.4) 1-1/4” (31.8) 1-1/2” (30.1)

103CCW - Drip Cap CCW 112 - 10’6-5/8” Lengths

Frame Technical DataMarch, 2009

L

Mullion Construction

L

10’6-5/8” (3216.3)

1” (25.4)

3/4” (19)

45˚DRIP CAP

C.C.W. 112

16 GA. (1.4) GALVANEAL

ORDER CODE: OM

Page 107: CURRIES Tech Data Frame Section.pdf5 Masonry Face Flush KD Frame Cased Opening Frame Technical Data March, 2015 VARIES 3” (76.2) MINIMUM 1” (25.4) 1-1/4” (31.8) 1-1/2” (30.1)

104Removable Vertical Mullion/BracketFrame Technical Data

August, 2003

L

MULLION BRACKET IS USED AT THE TOP AND BOTTOM OF FRAME

ATTACH MULLION BRACKET TO FRAME

NOTCH MULLION FACE TO ALLOW DIMENSION “D” TO PASS THRU.

SLIDE MULLION IN PLACE

DIM. “B” = JAMB DEPTH - FRAME GAUGE THICKNESSDIM. “D” = DETERMINED BY FACE DIMENSION

*

*

EQUAL TO FACE DIM. MINUS 1/4” (6.4)

2”(50.8)

1” (25.4)

“D”

ARC WELD2 PLACES MINIMUM

DIM “B”

DRILL 3/16” (4.8)2 HOLES

12-24 TAPSCREWS INSTALLED

*

ANCHOR PART NUMBER: P0090

NOTE: THE MULLION WILL BE REMOVABLE FROM THE FACE OPPOSITE THE DOOR RABBET.

Page 108: CURRIES Tech Data Frame Section.pdf5 Masonry Face Flush KD Frame Cased Opening Frame Technical Data March, 2015 VARIES 3” (76.2) MINIMUM 1” (25.4) 1-1/4” (31.8) 1-1/2” (30.1)

105Removable Horizontal Mullion/Bracket

Frame Technical DataJuly, 2014

L

NOTE: USED WITH REMOVABLE TRANSOM PANEL.

Page 109: CURRIES Tech Data Frame Section.pdf5 Masonry Face Flush KD Frame Cased Opening Frame Technical Data March, 2015 VARIES 3” (76.2) MINIMUM 1” (25.4) 1-1/4” (31.8) 1-1/2” (30.1)

106Splice Connection Head or JambFrame Technical Data

April, 2002

L

Field Splice Connection with Bracket

L

1. FIT SPLICING SLEEVE REINF. HALFWAY INTO ONE SIDE AND TACK WELD IN PLACE.2. SLIP OTHER SIDE OVER SPLICING SLEEVE REINF. AND ALIGN SEAMS FOR STRAIGHTNESS.3. TACK WELD SPLICING SLEEVE REINF. INSIDE AND TACK WELD OUTSIDE SEAM AT BOTH FACES.4. CONTINUOUS WELD SEAM - GRIND AND FINISH SMOOTH.

12” (304.8)

12 GA. (1.9) SPLICING REINF.

ANCHOR PART NUMBER: P0155

12 GA. (2.6)FIELD SPLICING SLEEVE

ARC WELD INSIDE

ARC WELD INSIDE

FIELD SPLICE WITH BRACKETFIELD WELD & FASTEN WITH SCREWS

3” (76.2)

ANCHOR PART NUMBER: P0156

NOTES FOR LABELING PURPOSES:1) NOTCH SOFFIT OF ADJOINING PIECE.2) ARC WELD SPLICING SLEEVE BRACKET TO MULLION.3) FULL WELD FACES OF BOTH PIECES TOGETHER, OR ATTACH WITH 3 #10 SCREWS THROUGH FACE INTO FIELD SPLICING SLEEVE BRACKET.

Page 110: CURRIES Tech Data Frame Section.pdf5 Masonry Face Flush KD Frame Cased Opening Frame Technical Data March, 2015 VARIES 3” (76.2) MINIMUM 1” (25.4) 1-1/4” (31.8) 1-1/2” (30.1)

107KD Double Egress Frame Standards

Frame Technical DataMay, 2010

LHANDING

LHRRH LH

RHR

DOUBLE RIGHT HAND SWING(STANDARD)

2

1

3 MEETING EDGE

5-3/4” (146.1) JAMB DEPTH HAS 7/16” (11.1) RETURN 18, 16, 14 GA.12 GA. 1/2” RETURN NO KD

2-5/8”(79.4)

4-3/4” (120.7) MIN.14” (355.6) MAX.

EQUAL

1-15/16”(49.2)

EQUAL

THROATOPENING

*1/2” (12.7)

*1/2” (12.7)

2” (50.8)

1-3/8” (34.9) 5/8” (15.9)

FINISHOPENINGWIDTH

1 JAMB

2 HEAD

THROATOPENING

1/2” (12.7)

1/2” (12.7)

2-5/8” (79.4)

4” (101.6) MIN.14” (355.6) MAX.

2” (50.8)

5/8” (15.9)

* *

*

M - FLUSH SERIES KDC - DRYWALL KD NOT AVAILABLE

3

3/32” (.094) CL HEAD

3/16” (.188)

SOFFIT STOP IS HELD BACK 3/32” TO PROVIDE PROPER DOOR CLEARANCE

Page 111: CURRIES Tech Data Frame Section.pdf5 Masonry Face Flush KD Frame Cased Opening Frame Technical Data March, 2015 VARIES 3” (76.2) MINIMUM 1” (25.4) 1-1/4” (31.8) 1-1/2” (30.1)

108S.B.E. Double Egress Frame Corner JointsFrame Technical Data

November, 2004

L RETURN FILLER

RETURN FILLER

WELD

RETURN FILLER

VERTICAL BUTT JOINT(STANDARD)WELDED &GROUND SMOOTH

HORIZONTAL BUTT JOINT(OPTIONAL)WELDED &GROUND SMOOTH

Page 112: CURRIES Tech Data Frame Section.pdf5 Masonry Face Flush KD Frame Cased Opening Frame Technical Data March, 2015 VARIES 3” (76.2) MINIMUM 1” (25.4) 1-1/4” (31.8) 1-1/2” (30.1)

109CCW - Open Back Rail - 10’6-5/8” Lengths

Frame Technical DataNovember, 2004

L

6’8” (2032) LOCATION 3 HINGES C.C.W. 247’0” (2133.6) LOCATION 3 HINGES C.C.W. 257’2” (2184.4) LOCATION 3 HINGES C.C.W. 39

OPEN BACK RAILHINGE JAMB

7’10” (2387.6) LOCATION 4 HINGES C.C.W. 628’0” (2438.4) LOCATION 4 HINGES C.C.W. 639’0” (2743.2) LOCATION 4 HINGES C.C.W. 11910’0” (3048) LOCATION 4 HINGES C.C.W. 120

OPEN BACK RAILHINGE JAMB

FOR 1-3/4” (44.5) DOORS ALL STRIKE LOCATIONS 40” (1016)IF PUNCHED - SILENCERS ARE REQUIREDWHEN ORDERING CCW 26 STRIKE JAMB SPECIFY DOOR HEIGHT

OPEN BACK RAILSTRIKE JAMB

CL

NOTE: ANCHORS ARE NOT INCLUDED WITH CCW MATERIAL. CCW MATERIAL MAY BE ORDERED CUT TO LENGTH - EXACT LENGTH - WITH S.M.O. OR S.B.E. CORNER CONFIGURATION. CUSTOM PROFILES AVAILABLE. 12 GA. FRAMES ARE CCW. 5-3/4 JAMB DEPTH HAS 1/2” RETURNS.

C.C.W. 26

10’6-5/8” (3216.3)

Page 113: CURRIES Tech Data Frame Section.pdf5 Masonry Face Flush KD Frame Cased Opening Frame Technical Data March, 2015 VARIES 3” (76.2) MINIMUM 1” (25.4) 1-1/4” (31.8) 1-1/2” (30.1)

110CCW - Mullion Closed Section - 10’6-5/8” LengthsFrame Technical Data

November, 2004

L

6’8” (2032) LOCATION 3 HINGES C.C.W. 427’0” (2133.6) LOCATION 3 HINGES C.C.W. 437’2” (2184.4) LOCATION 3 HINGES C.C.W. 44

MULLION - CLOSED SECTIONHINGE JAMB

7’10” (2387.6) LOCATION 4 HINGES C.C.W. 818’0” (2438.4) LOCATION 4 HINGES C.C.W. 829’0” (2743.2) LOCATION 4 HINGES C.C.W. 13310’0” (3048) LOCATION 4 HINGES C.C.W. 134

MULLION -CLOSED SECTIONHINGE JAMB

FOR 1-3/4” (44.5) DOORS ALL STRIKE LOCATIONS 40” (1016)IF PUNCHED - SILENCERS ARE REQUIREDWHEN ORDERING CCW 41 STRIKE JAMB SPECIFY DOOR HEIGHT

MULLION -CLOSED SECTIONSTRIKE JAMB

CL

C.C.W. 41

10’6-5/8” (3216.3)

12 GA. FRAMES ARE CCW

Page 114: CURRIES Tech Data Frame Section.pdf5 Masonry Face Flush KD Frame Cased Opening Frame Technical Data March, 2015 VARIES 3” (76.2) MINIMUM 1” (25.4) 1-1/4” (31.8) 1-1/2” (30.1)

111CCW - Mullion Closed Section - 10’6-5/8” Lengths

Communicating MullionFrame Technical Data

November, 2004

L10’6-5/8” (3216.3)

MULLION - CLOSED SECTIONCOMBINATION RAILALL STANDARDDOOR HEIGHTS.

DOUBLE HINGE, DOUBLESTRIKE OR HINGE ANDSTRIKE COMBINATIONS.

6’8” (2032) LOCATION 3 HINGES & STRIKE C.C.W. 457’0” (2133.6) LOCATION 3 HINGES & STRIKE C.C.W. 467’2” (2184.4) LOCATION 3 HINGES & STRIKE C.C.W. 477’10” (2387.6) LOCATION 4 HINGES & STRIKE C.C.W. 838’0” (2438.4) LOCATION 4 HINGES & STRIKE C.C.W. 849’0” (2743.2) LOCATION 4 HINGES & STRIKE C.C.W. 13510’0” (3048) LOCATION OF 4 HINGES & STRIKE C.C.W. 136DOUBLE STRIKE MULLION C.C.W. 85NOTE: WHEN ORDERING CCW 85 SPECIFY DOOR HEIGHT.6’8” (2032) LOCATION 3 (DOUBLE HINGES) C.C.W. 867’0” (2133.6) LOCATION 3 (DOUBLE HINGES) C.C.W. 877’2” (2184.4) LOCATION 3 (DOUBLE HINGES) C.C.W. 887’10” (2387.6) LOCATION 4 (DOUBLE HINGES) C.C.W. 898’0” (2438.4) LOCATION 4 (DOUBLE HINGES) C.C.W. 909’0” (2743.2) LOCATION 4 (DOUBLE HINGES) C.C.W. 13710’0” (3048) LOCATION OF 4 (DOUBLE HINGES) C.C.W. 138

NOTE: WHEN ORDERING COMBINATION MULLION DOUBLE HINGE, DOUBLE STRIKE, OR HINGE AND STRIKE, PROVIDE SECTION DETAIL OF DOOR RABBET LOCATION.

EXAMPLE

12 GAUGE FRAMES ARE CCW

Page 115: CURRIES Tech Data Frame Section.pdf5 Masonry Face Flush KD Frame Cased Opening Frame Technical Data March, 2015 VARIES 3” (76.2) MINIMUM 1” (25.4) 1-1/4” (31.8) 1-1/2” (30.1)

112CCW Sills - CCW 28, 139, 140, 48, 49, 55 - 10’6-5/8” LengthsFrame Technical Data

November, 2004

L

4” (101.6)6” (152.4)8” (203.2)

JAMB DEPTH

FULL JAMB DEPTH 4” (101.6) FACE OR LESS C.C.W. 28FULL JAMB DEPTH 6” (152.4) FACE OR LESS C.C.W. 139FULL JAMB DEPTH 8” (203.2) FACE OR LESS C.C.W. 140

6-13/16” (173)

JAMB DEPTH

FULL JAMB DEPTH 6-13/16” (173) FACE C.C.W. 55

4” (101.6)6” (152.4)8” (203.2)

5/8” (15.9)

1-9/16” (39.7)

SPECIAL 1-9/16” (39.7) THICK C.C.W. 48

4” (101.6)6” (152.4)8” (203.2)

5/8” (15.9)

1-15/16” (49.2)

SPECIAL 1-15/16” (49.2) THICK C.C.W. 49

10’6-5/8” (3216.3)

12 GAUGE FRAMES ARE CCW

Page 116: CURRIES Tech Data Frame Section.pdf5 Masonry Face Flush KD Frame Cased Opening Frame Technical Data March, 2015 VARIES 3” (76.2) MINIMUM 1” (25.4) 1-1/4” (31.8) 1-1/2” (30.1)

113CCW - Plain Mullion CCW 16, 17, 18, 50 - 10’6-5/8” Lengths

Frame Technical DataNovember, 2004

L

10’6-5/8” (3216.3) 2” (50.8) FACE

JAMB DEPTH

PLAIN MULLION 2” (50.8) FACE C.C.W. 16

4” (101.6) FACE

JAMB DEPTH

PLAIN MULLION 4” (101.6) FACE C.C.W. 17

6” (152.4) FACE

JAMB DEPTH

PLAIN MULLION 6” (152.4) FACE C.C.W. 18

8” (203.2) FACE

JAMB DEPTH

PLAIN MULLION 8” (203.2) FACE C.C.W. 50

12 GAUGE FRAMES ARE CCW

Page 117: CURRIES Tech Data Frame Section.pdf5 Masonry Face Flush KD Frame Cased Opening Frame Technical Data March, 2015 VARIES 3” (76.2) MINIMUM 1” (25.4) 1-1/4” (31.8) 1-1/2” (30.1)

114CCW - Plain Rail CCW 21, 23, 115, 117 - 10’6-5/8” LengthsFrame Technical Data

November, 2004

L

10’6-5/8” (3216.3)2” (50.8) FACE

JAMB DEPTH

PLAIN RAIL 2” (50.8) FACE C.C.W. 21

JAMB DEPTH

PLAIN RAIL 4” (101.6) FACE C.C.W. 23

JAMB DEPTH

PLAIN RAIL 6” (152.4) FACE C.C.W. 115

4” (101.6) FACE

6” (152.4) FACE

JAMB DEPTH

PLAIN RAIL 8” (203.2) FACE C.C.W. 117

8” (203.2) FACE

12 GAUGE FRAMES ARE CCW

Page 118: CURRIES Tech Data Frame Section.pdf5 Masonry Face Flush KD Frame Cased Opening Frame Technical Data March, 2015 VARIES 3” (76.2) MINIMUM 1” (25.4) 1-1/4” (31.8) 1-1/2” (30.1)

115Sill ReinforcementFrame Technical Data

August, 2003

LANCHOR PART NUMBER: P320

LOCATED EVERY 18” OF SILL LENGTH WHEN FACE EXCEEDS 5”.PROVIDES ADDITIONAL SUPPORT TO PROFILE FACE.

2” (50.8)

1-1/2” (38.1)

12 GA. (2.6)

ONE STIFFENER EVERY 18” OF LENGTH ON FACE DIMENSIONS 5” TO 9” FACE DIMENSIONS 9” THRU 16” MAX. REQUIRE TWO STIFFENERS PER 18” OF LENGTH.

Page 119: CURRIES Tech Data Frame Section.pdf5 Masonry Face Flush KD Frame Cased Opening Frame Technical Data March, 2015 VARIES 3” (76.2) MINIMUM 1” (25.4) 1-1/4” (31.8) 1-1/2” (30.1)

116CCW - Misc. Rail CCW 19, 27, 22, 29 - 10’6-5/8” LengthsFrame Technical Data

November, 2004

L

JAMB DEPTH

COVER PLATECORNER OR FLAT

10’6-5/8” (3216.3)

C.C.W. 19

FILLER PLATE WITHOUT STOP

C.C.W. 27

FILLER PLATE WITH STOP

C.C.W. 22

HEAD CAP

C.C.W. 29

JAMB DEPTH

JAMB DEPTH

JAMB DEPTH

OR

CORNER

FLAT

12 GAUGE FRAMES ARE CCW

Page 120: CURRIES Tech Data Frame Section.pdf5 Masonry Face Flush KD Frame Cased Opening Frame Technical Data March, 2015 VARIES 3” (76.2) MINIMUM 1” (25.4) 1-1/4” (31.8) 1-1/2” (30.1)

117CCW - Misc. Rail CCW 91, 92, 40 - 10’6-5/8” Lengths

Frame Technical DataNovember, 2004

L

10’6-5/8” (3216.3)

JAMB DEPTH

JAMB DEPTH

JAMB DEPTH

CHANNEL HEAD REINF.

C.C.W. 91

FULL WIDTH HEAD REINF.

C.C.W. 92

CASED OPENING PLAIN RAILCASED OPENING PLAIN RAIL 4” (101.6)

C.C.W. 40 2” FACEC.C.W. 20 4” FACE

12 GAUGE FRAMES ARE CCW

Page 121: CURRIES Tech Data Frame Section.pdf5 Masonry Face Flush KD Frame Cased Opening Frame Technical Data March, 2015 VARIES 3” (76.2) MINIMUM 1” (25.4) 1-1/4” (31.8) 1-1/2” (30.1)

118CCW - Corners CCW 51, 52, 53, 54 - 10’6-5/8” LengthsFrame Technical Data

November, 2004

L

JAMB DEPTH

1-15/16”(49.2)

1-9/16”(39.7)

2 WAY CORNER1-9/16” (39.7) OUTSIDE

C.C.W. 51

JAMB DEPTH

1-15/16”(49.2)

1-9/16”(39.7)

JAMB DEPTH

1-15/16”(49.2)

1-9/16”(39.7)

2 WAY CORNER1-15/16” (49.2) OUTSIDE

C.C.W. 52

JAMB DEPTH

1-15/16”(49.2)

1-9/16”(39.7)

JAMB DEPTH

1-15/16”(49.2)

1-9/16”(39.7)

3 WAY CORNER1-9/16” (39.7) OUTSIDE

C.C.W. 53

JAMB DEPTH

1-15/16”(49.2)

1-9/16”(39.7)

1-15/16”(49.2)

1-9/16”(39.7)

JAMB DEPTH

1-15/16”(49.2)

1-9/16”(39.7)

3 WAY CORNER1-15/16” (49.2) OUTSIDE

C.C.W. 54

JAMB DEPTH

1-15/16”(49.2)

1-9/16”(39.7)

1-15/16”(49.2)

1-9/16”(39.7)

12 GAUGE FRAMES ARE CCW

Page 122: CURRIES Tech Data Frame Section.pdf5 Masonry Face Flush KD Frame Cased Opening Frame Technical Data March, 2015 VARIES 3” (76.2) MINIMUM 1” (25.4) 1-1/4” (31.8) 1-1/2” (30.1)

119CCW - Glass Stop

Frame Technical DataNovember, 2004

L CCW# HEIGHT X WIDTH DESCRIPTION 93 5/8” (15.9) X 5/8” (15.9) PRIME PAINT - PUNCHED 12” (304.8) ON CENTER 97 5/8” (15.9) X 5/8” (15.9) PRIME PAINT - BLANK 101 5/8” (15.9) X 5/8” (15.9) NO PAINT - BLANK 105 5/8” (15.9) X 5/8” (15.9) NO PAINT - PUNCHED 12” (304.8) ON CENTER

94 5/8” (15.9) X 1” (25.4) PRIME PAINT - PUNCHED 12” (304.8) ON CENTER 98 5/8” (15.9) X 1” (25.4) PRIME PAINT - BLANK 102 5/8” (15.9) X 1” (25.4) NO PAINT - BLANK 106 5/8” (15.9) X 1” (25.4) NO PAINT - PUNCHED 12” (304.8) ON CENTER

95 3/4” (19) x 5/8” (15.9) PRIME PAINT - PUNCHED 12” (304.8) ON CENTER 99 3/4” (19) x 5/8” (15.9) PRIME PAINT - BLANK 103 3/4” (19) x 5/8” (15.9) NO PAINT - BLANK 107 3/4” (19) x 5/8” (15.9) NO PAINT - PUNCHED 12” (304.8) ON CENTER

96 3/4” (19) X 1” (25.4) PRIME PAINT PUNCHED 6” (152.4) ON CENTER 100 3/4” (19) X 1” (25.4) PRIME PAINT - BLANK 104 3/4” (19) X 1” (25.4) NO PAINT - BLANK 108 3/4” (19) X 1” (25.4) NO PAINT - PUNCHED 6” (152.4) ON CENTER

143 1” (25.4) X 1” (25.4) - PRIME PAINT - PUNCHED 6” (152.4) ON CENTER GLASS STOP IS MANUFACTURED FROM GALVANEALED STEEL. PAINT IS CURRIES STANDARD GRAY PRIME. PUNCHING IS FOR OVAL HEAD SCREWS SIZE #8.

NOTE: HOLE PUNCHING ON GLASS STOP IS STANDARD 12” (304.8) ON CENTER. IF STOP IS TO BE USED FOR LABEL FRAME APPLICATIONS YOU MUST SPECIFY ON ORDER THAT HOLES ARE TO BE 6” (152.4) ON CENTER.

ALL GLASS STOP AND SOFFIT STOP MATERIAL COME IN 10’6” (3200.4) LENGTHS

STAINLESS STEEL GLASS STOP IS 16 GA. (1.4)

5/8”(15.9)

5/8”(15.9)

5/8”(15.9)

1”(25.4)

3/4”(19)

5/8”(15.9)

3/4”(19)

1”(25.4)

1”(25.4)

1”(25.4)

9/32” (7.1)

16 GA.

16 GA.

16 GA.

18 GA.

18 GA.

Page 123: CURRIES Tech Data Frame Section.pdf5 Masonry Face Flush KD Frame Cased Opening Frame Technical Data March, 2015 VARIES 3” (76.2) MINIMUM 1” (25.4) 1-1/4” (31.8) 1-1/2” (30.1)

120CCW - Shipping Spreader Bar CCW 111 - 10’6-5/8” LengthsFrame Technical Data

April, 2002

L

TACK WELD SHIPPING SPREADER BAR TO BOTTOM OFFRAME RABBET INSIDE NOMINAL FRAME OPENING.

TOP VIEW LOOKING DOWN

3/8” (9.5)

1” (25.4)

NOTE: CURRIES HOLLOW METAL FRAMES HAVE DOUBLE SHIPPING SPREADER BARS WELDED ON THE BOTTOM. THE SPREADER BARS MUST BE REMOVED AND A SETTING SPREADER USED FOR FINAL INSTALLATION. A COLD CHISEL AND HAMMER ARE RECOMMENDED TOOLS TO USE TO REMOVE THESE. THE FRAME INSTALLER AS-SUMES ALL RESPONSIBILITY FOR PLUMB FRAME INSTALLATION.

Page 124: CURRIES Tech Data Frame Section.pdf5 Masonry Face Flush KD Frame Cased Opening Frame Technical Data March, 2015 VARIES 3” (76.2) MINIMUM 1” (25.4) 1-1/4” (31.8) 1-1/2” (30.1)

121Custom Frame Profiles

Frame Technical DataFebruary, 2016

LCONTACT FACTORY FOR CAPABILITIES

3/4” (19.1)MINIMUM

1” (25.4)MINIMUM

1/2” (12.7)MINIMUM

289 3/4” (19.1)MINIMUM

1” (25.4)MINIMUM

1/2” (12.7)MINIMUM

B

3/8” (9.5)MINIMUM

VARIES

VARIES

1/8” (3.2) 16 GA. (1.4)MINIMUM

F

5/32” (4) 14 GA. (1.9)MINIMUM

NOTE: FOR 12 GA. (2.6) CONTACT FACTORY

Page 125: CURRIES Tech Data Frame Section.pdf5 Masonry Face Flush KD Frame Cased Opening Frame Technical Data March, 2015 VARIES 3” (76.2) MINIMUM 1” (25.4) 1-1/4” (31.8) 1-1/2” (30.1)

122Custom Frame ProfilesFrame Technical DataJune, 2020

L

3/4” (19.1)MINIMUM

1-1/2” (38.1)MINIMUM4” (101.6)MAXIMUM

2” (50.8)MINIMUM4” (101.6)MAXIMUM

2” (50.8)MAXIMUM*

* NOTE: 1” STANDARD RETURNS

* NOTE: 1.125” STANDARD RETURNS

MH

1/2” (12.7)MINIMUM*

NOTE THROAT OPENING WHEN ORDERING

1/2” (12.7) RADIUS ONLY

1/2” (12.7)

3/4” (19.1)MINIMUM

1” (25.4)MINIMUM

2” (50.8)MAXIMUM

L

1/2” (12.7)MINIMUM

1/2” (12.7)

3/8” (9.5)MINIMUM

3/4” (19.1)MINIMUM

1” (25.4)MINIMUM

1/8” (3.2) 16 GA. (1.4)3/16” (4.8) 14 GA. (1.9)

INOT 12 GA. (2.6)

16 GA. ONLY

1/2” (12.7)ONLY

1/2” RADIUS

1/4” (6.4)ONLY

275 4” MIN. (101.6)9-3/4” MAX. (247.7)

4” MIN. (101.6)9-3/4” MAX. (247.7)

2” (50.8)MAXIMUM*

1/2” (12.7)MINIMUM*

NOTE THROAT OPENING WHEN ORDERING

16 GA. ONLY

Page 126: CURRIES Tech Data Frame Section.pdf5 Masonry Face Flush KD Frame Cased Opening Frame Technical Data March, 2015 VARIES 3” (76.2) MINIMUM 1” (25.4) 1-1/4” (31.8) 1-1/2” (30.1)

123Mercury Thermal Break Frame KD Flush Profile

Frame Technical DataApril, 2020

LSINGLE RABBET: 3-3/4" (95.3) THRU 5-5/8" (142.9) JAMB DEPTH DOUBLE RABBET: 5-3/4" (146.1) THRU 14" (355.6) JAMB DEPTH14 GA. (1.9) AND 16 GA. (1.4) GALVANEALED STEEL5/8” (15.9) HIGH STOP ONLYKD, FACE ONLY WELD, OR FULL WELD (SOFFIT IS NOT WELDED)MAXIMUM KD LENGTH - 8’0” JAMB, 8’0” HEADPUNCH FOR SILENCERS NOT AVAILABLE

ANCHOR OPTIONS: WIRE ANCHOR SPLIT BASE ANCHOR SPLIT WOODSTUD ANCHOR EXISTING WALL ANCHOR

NFRC 102 U AND R VALUES STANDARDIZED THERMAL TRANSMITTANCE MERCURY FRAME & TRIO-E FLUSH DOOR - U VALUE 0.36, R VALUE 2.78 MERCURY FRAME & MERCURY FLUSH DOOR - U VALUE 0.37 R VALUE 2.70

NFRC 400 AIR INFILTRATION (CFM/SQ FT) MERCURY FRAME & TRIO-E FLUSH DOOR - 0.1 MERCURY FRAME & MERCURY FLUSH DOOR - 0.1

1” (25.4) - 4” (101.6)FACE ON HEAD IN 1/8” INCREMENTS

DOOR RABBET

THERMAL BREAK

SINGLE RABBET: 3-3/4” (95.3) THRU 5-5/8” (142.9) JAMB DEPTH

DOUBLE RABBET: 5-3/4” (146.1) THRU 14” (355.6) JAMB DEPTH

THERMAL BREAK

DOORRABBET

1” (25.4) - 4” (101.6)FACE ON JAMB IN 1/8” INCREMENTS

PEMKO S44 SHIPS LOOSE WITH FRAME,TO BE FIELD INSTALLED AFTER FINISH PAINT.

Page 127: CURRIES Tech Data Frame Section.pdf5 Masonry Face Flush KD Frame Cased Opening Frame Technical Data March, 2015 VARIES 3” (76.2) MINIMUM 1” (25.4) 1-1/4” (31.8) 1-1/2” (30.1)

124Mercury Thermal Break Frame CCW Stick ComponentsFrame Technical Data

September, 2016

L16 GA. (1.4) AND 14 GA. (1.9) GALVANEALED STEEL ONLY5/8” (15.9) HIGH STOPS ONLY BUTT END JOINTS ONLYNOT LABELED

MERCURY U VALUE - 0.37MERCURY R VALUE - 2.70

MULLION - 16 GA. (1.4) AND 14 GA. (1.9) PUNCH FOR SILENCERS NOT AVAILABLE.

THERMAL BREAK

THERMAL BREAK

5-3/4” (146.1)THRU 14” (355.6)

JAMB DEPTH

3-3/4” (95.3) THRU 5-5/8” (142.9) JAMB

DEPTH AVAILABLE SINGLE RABBET

THERMAL BREAK

Page 128: CURRIES Tech Data Frame Section.pdf5 Masonry Face Flush KD Frame Cased Opening Frame Technical Data March, 2015 VARIES 3” (76.2) MINIMUM 1” (25.4) 1-1/4” (31.8) 1-1/2” (30.1)

125Mercury Thermal Break Frame Profiles with Stucco Flange

Frame Technical DataOctober, 2018

TQU Profiles

TRU Profiles

TQU PROFILE TRU PROFILE

A. GAUGE16 (MAX SIZE 8’0" X 8’0")14 (MAX SIZE 8’0" X 8’0")

16 (MAX SIZE 8’0" X 8’0")14 (MAX SIZE 8’0" X 8’0")

B. MATERIALCOLD ROLLEDASTM A60 GALVANNEALEDASTM G90 GALVANIZED

COLD ROLLEDASTM A60 GALVANNEALEDASTM G90 GALVANIZED

C. FINISH PRIME PAINTED PRIME PAINTED

D. DEPTH 5-3/4" TO 14" 3-7/8" TO 5-5/8"

E.THROATSINGLE RABBET

1-3/16" LESS THAN DEPTH (OUTSWING/INSWING)1-3/8" LESS THAN DEPTH (STUCCO)

1-3/16" LESS THAN DEPTH (OUTSWING/INSWING)1-3/8" LESS THAN DEPTH (STUCCO)

F. FACE 1" THRU 4" 1" THRU 4"

G. STOP HEIGHT 5/8" 5/8"

H. CORNER CONDITION KD (WITHOUT TABS) OR SETUP AND WELDED * KD (WITHOUT TABS) OR SETUP AND WELDED *

I.OPENING WIDTH SINGLEOPENING WIDTH DOUBLE

2’0" TO 4’0"4’0" TO 8’0"

2’0" TO 4’0"4’0" TO 8’0"

J. OPENING HEIGHT 2’0" TO 8’0" 2’0" TO 8’0"

K. RABBET 1-15/16" 1-15/16"

L. SOFFIT 1-7/8" MIN. 1-7/8" MIN.

M1.M2.

BACKBENDBACKBEND (FLANGE SIDE)

1/2"5/8” STD. 1/2” MIN.

1/2"5/8” STD. 1/2” MIN.

N1. FLANGE 1/2" STANDARD, 1/2" MIN. 3" MAX. 1/2” STANDARD, 1/2” MIN. 3” MAX.

NOTE: SOME OF THESE COMBINATIONS, DUE TO MANUFACTURING CLEARANCE, MUST BE MADE IN MULTIPLE PIECES.* FULLY WELDED THERMALLY BROKEN FRAMES WILL BE LIMITED TO FACE MITER WELDS, HEAD AND JAMB RABBET SEAM WELDS ONLY.

PEMKO S44 SHIPS LOOSE WITH FRAME, TO BE FIELD INSTALLED AFTER FINISH PAINT.

ALL DIMENSIONS SHOWN ARE STANDARD. FOR VARIATIONS REFER TO THE CHART FOR LIMITS.

ANCHORS ATTACHMENT

MASONRYWIRE MASONRY ANCHOR

EXISTING OPENING

WELDED IN

WOOD STUD STRAPS ONLY

WELDED IN

SPLIT FIXED FLOOR

WELDED IN

(Conversion: 1" = 25.4 mm, e.g., 1-3/4" = 44.45 mm)

Page 129: CURRIES Tech Data Frame Section.pdf5 Masonry Face Flush KD Frame Cased Opening Frame Technical Data March, 2015 VARIES 3” (76.2) MINIMUM 1” (25.4) 1-1/4” (31.8) 1-1/2” (30.1)

126Steel Channel Anchor Installation Frame Technical Data

November, 2014

L

TWIST 45˚ TOCLEAR THE RETURNS.

TWIST THE ANCHORUPRIGHT.

ROTATE THEANCHOR CLOCKWISE TOTIGHTEN IN THEPROFILE.

ROTATE TO GET THEANCHOR LEGSUNDER THE PROFILE RETURNS.

ROTATE ANCHOR 45˚TO CLEAR RETURNS.SLIDE INTO PROFILE.

Page 130: CURRIES Tech Data Frame Section.pdf5 Masonry Face Flush KD Frame Cased Opening Frame Technical Data March, 2015 VARIES 3” (76.2) MINIMUM 1” (25.4) 1-1/4” (31.8) 1-1/2” (30.1)

127Door Silencers

Frame Technical DataOctober, 2002

TOP OFSTRIKECUTOUT

SILENCERS

8” (203.2)

10” (254)

2” (50.8)

SINGLE DOORFRAME

SILENCERS

CL

5” (127)

5” (127)

PAIR OF DOORS FRAME

ADHESIVE TYPE

ADHESIVE BACKED SILENCERSFIELD APPLIED AFTER FINISH PAINTING

PUNCH TYPE

17/64” (6.8) DIA. HOLETO ACCEPT PUSH IN

TYPE SILENCERS

17/64” (6.8) 5/8” (15.9)

ADHESIVEBACKING

Page 131: CURRIES Tech Data Frame Section.pdf5 Masonry Face Flush KD Frame Cased Opening Frame Technical Data March, 2015 VARIES 3” (76.2) MINIMUM 1” (25.4) 1-1/4” (31.8) 1-1/2” (30.1)

128Loose Spline SleeveFrame Technical Data

September, 2003

JAMB DEPTH-5/16” (7.9)

4” (101.6)

PART #P20016 (1.4) GA.

4 SPOTWELDS

16 GA. (1.4)

PART #P200

L

Page 132: CURRIES Tech Data Frame Section.pdf5 Masonry Face Flush KD Frame Cased Opening Frame Technical Data March, 2015 VARIES 3” (76.2) MINIMUM 1” (25.4) 1-1/4” (31.8) 1-1/2” (30.1)

129KD Frame Assembly Instructions

Frame Technical DataSeptember, 2011

NOTE ON WELDED FRAMES: Shipping bars should NOT be used as spreader. Remove ship-ping bar before setting frame.

Plumbing the frameThe contractor should be equipped with a carpenter level, square and spreader. Set the frame in desired location and level the header. Square jambs to header. Shim under jambs if necessary. With frame in place, set spreader and fasten jambs to floor through floor anchors.

BRACING FRAMES BEFORE WALL CONSTRUCTION FOR KD AND WELDED FRAMES

MASONRY FRAMES, THERMAL BREAK, AND CURRISEAL FOR MASONRY, METAL STUD, AND WOOD STD WALLS

Bracing the frameBrace the frame as shown or shore to a structure above. Brace in the direction of intended wall. Plumb and square jambs. Install vertical brace to support header for openings over 4’0” wide.

Squaring the FrameThe installer should use wood spreaders (as described below), a carpenters level (the longer the better), and a full size carpenters square. Set the frame in the desired location. Level head and plumb jambs. Shim under jambs if necessary.

Job StorageStore frames off the ground on wood runners or skids. Do not store directly on the ground. Cover frames with tarpaulin or plastic but do insure that adequate ventilation is provided to eliminate moisture condensation. When frames are to be fully grouted and when plaster or mortar contain “anti-freeze” agents, the inside of the frames should be coated with a bituminous, water-resistant paint by the installation contractor.

SpreaderTypical wood spreader must be square and made from lumber at least 1” thick. Length of spreader equals door opening width at the head. Cut clearance notches for frame stops as shown. Spreader must be nearly as wide as frame depth for accurate installation.

Assembly of Frame Plumbing of Frame

SpreaderTypical wood spreader must be square and fabricated from lumber no less than 1” thick. Correct length is the door opening width between the jambs at the header (i.e., Single Door 3’0” = 36”). Cut clearance notches for frame stops. Spreader must be nearly as wide as frame depth for accurate installation.

LEVEL

#8 SCREW (MS002485)(REQUIRED ON ALL KD APPLICATIONS)

HEAD

JAMB

A A SECTION A-A

SPREADER

PLUM

B

SQUARE

DOOR OPNG. AT HEADER

FRAM

EDE

PTH

Page 133: CURRIES Tech Data Frame Section.pdf5 Masonry Face Flush KD Frame Cased Opening Frame Technical Data March, 2015 VARIES 3” (76.2) MINIMUM 1” (25.4) 1-1/4” (31.8) 1-1/2” (30.1)

130KD Frame Assembly InstructionsFrame Technical DataSeptember, 2011

NEW MASONRY CONSTRUCTION FOR KD AND WELDED FRAMES

WireAnchor

“T”Anchor

STEEL STUD WALL CONSTRUCTION WITH FLUSH OR RECESS TYPE ANCHORS FOR KD AND WELDED FRAMES

Elevation1. Assemble frame.2. Install anchors. Position anchors in frame through the throat and tap in with a hammer. Frames may also be supplied with anchors welded in place.3. Square, brace and plumb frame as shown.4. Set spreader. Attach jambs to floor through floor anchor or floor extension. Install jamb studs to floor and ceiling runners and tightly against frame anchors.5. Attach studs to frame anchors as shown below.

NOTE: Drywall must extend at least 1/2” into frame at fire rated installations.

Channel type steel studPosition studs in frame throat and attach to anchors with screws or weld. If using screws, the installer should drill from the back side of the stud, through both the stud and anchor, then attach with (2) screws per anchor location.

NOTE: When attaching header stud to jamb studs, be sure the stud is above frame header. This will assure ample room for attaching plaster lath or drywall and will not interfere with installation of hardware attached to frame header. Anchors are not required in frame heads, except fire listed double egress openings.

90˚ 90˚

HEADER STUD

JAMBSTUD

JAMBSTUD

SPREADER

FRAME

CHANNEL TYPEJAMB STUDS

1. Assemble frame.2. Set brace and plumb frame.3. Install anchors. Grout frame in the area of the anchors as block courses are laid up. Frames may also be supplied with anchors welded in place.4. A second spreader is recommended at the mid point of the door opening to maintain the door opening dimension.5. Continually check plumb and square as wall progresses.

Existing Masonry Construction1. Drill (4) 9/16” diameter holes evenly spaced in each jamb for 3/8” expansion shell anchors. Install multipurpose anchor at each 9/16” hole.2. Assemble 3 frame pieces flat on floor. Install (4) #8 x 1/2” sheet metal screws (included) at corners of head to each jamb (required for Underwriters Laboratories fire rating). Locate removable spacing bar at base of frame to maintain proper opening width during installation.3. Position assembled frame in opening. Plumb and level the frame. Shim frame as required.4. Anchor frame to wall with 3/8” expansion shell anchors, shimming behind anchors as needed.

NOTE: Anchors in frame heads are not required.

90˚ 90˚

SPREADER

Page 134: CURRIES Tech Data Frame Section.pdf5 Masonry Face Flush KD Frame Cased Opening Frame Technical Data March, 2015 VARIES 3” (76.2) MINIMUM 1” (25.4) 1-1/4” (31.8) 1-1/2” (30.1)

131KD Frame Assembly Installation

Frame Technical DataSeptember, 2011

WOOD STUD CONSTRUCTION FOR KD AND WELDED FRAMES

WOOD STUD CONSTRUCTION (STUDS ERECTED BEFORE FRAME)

Erect frameAssemble frame. Stand frame up in desired location. Anchor one jamb to floor and set spreader on floor from anchored jamb to loose jamb. Plumb, level, and square frame. Position and anchor second jamb, then brace.

NOTE: Drywall must extend at least 1/2” into frame at fire rated installations.

1. Install anchors. Position anchors in frame throat and tap in with a hammer. Frames may also be supplied with anchors welded in place.2. Set spreader. Attach jambs to floor through floor anchor or floor extension. Install double jamb studs to floor and ceiling runners and header.3. Bend anchor tabs around stud leaving desired clearance between frame return and stud for inserting finished wall material.4. Square and nail top anchor to stud on ONE JAMB ONLY. Check plumb and square and continue to nail balance of anchors to stud. Repeat for opposite jamb.5. Anchors are not required in frame heads, except fire listed double egress openings.

Rough openingBuild rough opening. Rough opening dimensions for 2” face frames should be 4-1/4” - 4-1/2” larger than door width and 2-1/4” - 2-1/2” larger than door height. It is recommended that double studs be used at jambs and headers.

NOTE: Drywall must extend at least 1/2” into frame at fire rated installations.

1. Assemble frame.2. Install anchors. Position anchors in frame throat and tap in with a hammer. Frames may also be supplied with anchors welded in place. Base anchors may also be used. If base anchor cannot be used add one anchor per jamb at bottom.3. Place frame in rough stud opening.4. Bend anchor tabs around stud leaving desired clearance between frame return and stud for inserting finished wall material.5. Set spreader and level frame. Shim jambs if necessary.6. Square and nail top anchor to stud on ONE JAMB ONLY. Check plumb and square and continue to nail balance of anchors to stud. Repeat for oppo-site jamb.7. Anchors are not required in frame heads, except fire listed double egress openings.

ANGLEBRACES

SPREADER

FRAME

WOODSTUDS

FLOORRUNNER

JAMBSTUD

HEADER STUD

SPREADER

90˚ 90˚

ROUGHOPENING

DIMENSIONS

SPREADER

90˚

WOODSTUDS

FRAME

90˚

Page 135: CURRIES Tech Data Frame Section.pdf5 Masonry Face Flush KD Frame Cased Opening Frame Technical Data March, 2015 VARIES 3” (76.2) MINIMUM 1” (25.4) 1-1/4” (31.8) 1-1/2” (30.1)

132NotesFrame Technical Data

August, 2017

ELECTROLUMINECENTLAMP

RACEWAY ACCESSKNOCKOUT

Page 136: CURRIES Tech Data Frame Section.pdf5 Masonry Face Flush KD Frame Cased Opening Frame Technical Data March, 2015 VARIES 3” (76.2) MINIMUM 1” (25.4) 1-1/4” (31.8) 1-1/2” (30.1)

133Security Sidelite Door Construction

Frame Technical DataMarch, 2007

FEATURES:

HINGED SECURITY PANEL CLOSES TO CREATE A VISUAL BARRIER

GLASS POCKETS AVAILABLE FOR UP TO 1” THICK GLASS

PREPARED FOR SELF LATCHING DEADBOLT TO MEET PROJECT REQUIREMENTS

STANDARD 4-1/2” X .134 HINGE PREPARATIONS

OPTIONS:

AVAILABLE WITH MASONRY AND STUD WALL ANCHORS

FIRE RATING:WARNOCK HERSEY3/4 HOUR RATING. (1-1/2 HOUR WITH SPECIALTY GLAZING)

USES:• CLASSROOMS• POST OFFICES• GOVERNMENT FACILITIES• AIRPORTS

16 OR 14 GA. FRAMES WITH WELDED CORNERS 6-3/4” MINIMUM DEPTH

OPERABLEPANEL

INSIDESECTIONOUTSIDE

GLASS

Page 137: CURRIES Tech Data Frame Section.pdf5 Masonry Face Flush KD Frame Cased Opening Frame Technical Data March, 2015 VARIES 3” (76.2) MINIMUM 1” (25.4) 1-1/4” (31.8) 1-1/2” (30.1)

HORIZONTAL ASTRAGAL REQUIRED.

PANEL - RATED - HONEYCOMB AND MINERAL CORENON-RATED - STEEL STIFFENED AND POLYSTYRENE

FRAME - 3 HR MAX. RATING11’4” MAX. HEIGHT4’ MAX. WIDTH SINGLE8’ MAX. WIDTH PAIR

134Transom Frame Removable Panel InstallationFrame Technical Data

April, 2012

L

16 GAUGE GUIDE CHANNEL

TOP OF PANEL NOTCHED FOR GUIDE CHANNELS

BOTH FACE SHEETS WELDED TO VERTICAL END CHANNELS, 6” O.C.

3/8” RETAINER PINS FOR REMOVABLE PANELS: WELDED TO INSIDE OF HEAD.6” FROM ENDS 18” MAX O.C.

TAPPED FOR 1/4-20 MS

1/4” STEEL PLATE

HORIZONTAL EDGES OF PANEL ARE WELDED TO CONTINUOUS CHANNEL

NOMINAL 1-3/4” THICK

1/4” STEEL PLATE WITH CLEAR HOLE

16 GAUGE GUIDE (END) CHANNELS BOTH SIDES

1/4-20 FHMS (2)

JAMB

TOP OF PANELBOTTOM OF PANEL

1-9/16”

7/8”

DRILL 1/4” AND COUNTERSINK

DOOR OPENING17/32” TO BOTTOM OF PANEL & 1/8” CLEARANCE TO TOP OF DOOR FROM BOTTOM OF PANEL

48” MAX.PANELHEIGHT

NOTE: PANEL AND TRANSOM FRAME REQUIRE SPECIAL CONSTRUCTION. MUST BE INDICATED ON BOTH DOOR AND FRAME ORDER.

Page 138: CURRIES Tech Data Frame Section.pdf5 Masonry Face Flush KD Frame Cased Opening Frame Technical Data March, 2015 VARIES 3” (76.2) MINIMUM 1” (25.4) 1-1/4” (31.8) 1-1/2” (30.1)

135Slip-on “N” Profile Door Frame

Frame Technical DataMay, 2018

INSTALL WITH NAILER HOLES IN FACE. AVAILABLE WITH OR WITHOUT COMPRESSION ANCHORS.

L

FIRE LABEL NOTES: WOOD TRIM SHALL BE APPLIED TO FRAME FACES WITH A FIRE LISTED CONTACT ADHESIVE AND /OR FAST CAP 2P-10 ADHESIVE. WOOD TRIM MUST BE HELD BACK FROM THE CORNER OF THE FRAME FACE (CLOSEST TO THE DOOR RABBET) APPROXIMATELY 1/4” - 3/8” .

N PROFILE STANDARD WILL BE COMPRESSION ANCHORS AND NAIL HOLES ON BOTH SIDES.NM PROFILE WILL NOT HAVE COMPRESSION ANCHORS. ANCHORS (WELDED IN ONLY) AND NAIL HOLES NEED TO BE SPECIFIED.

TABS

SLOTS

COMPRESSION ANCHOR DRIVER ACCESS HOLE

JAMBHEAD CORNER ASSEMBLY

COMPRESSIONANCHOR(OPTIONAL)

(HEIGHT)SEE CHART

WIDTHSEE CHART

2”

THROAT *

* ORDER USING JAMB DEPTHJAMB DEPTH = THROAT DIMENSION +1/8

FASTENER ATTCHMENT HOLES PUNCHED IN EACH FACE COMPRESSION AN-

CHOR OPTIONAL

SPECIFICATIONS:MAXIMUM SINGLE – 4’0” (1219) W X 9’-0” (2743) HMAXIMUM PAIR – 8’0” (2438) W X 9’0” (2743) H (NO DOUBLE EGRESS)THROAT – 3-3/4” (95) MIN TO 13” (330) MAX 3F ONLY.SINGLE AND DOUBLE RABBET ONLY (NO KERF)GAUGE: 16 GA. (1.5) MIN, 14 GA (1.8) MAX MATERIAL: COLD ROLLED OR GALVANNEALED STEELATTACHMENT HOLES: HOLES ARE LOCATED AT 16” MAX SPACING AND 2” MAX FROM ENDS.

Page 139: CURRIES Tech Data Frame Section.pdf5 Masonry Face Flush KD Frame Cased Opening Frame Technical Data March, 2015 VARIES 3” (76.2) MINIMUM 1” (25.4) 1-1/4” (31.8) 1-1/2” (30.1)

136Slip-On Hybrid Drywall Door FrameFrame Technical Data

May, 2018

L

TABSLOT

CORNER CLIP

90 MINUTE MAXIMUM RATING(INTERTEK ONLY)

HEAD

JAMB CORNERASSEMBLY

COMPRESSIONANCHOR

COMPRESSIONANCHOR

PUNCH AND DIMPLE ON DRYWALL RETURN SIDE

THROAT

2” (49)

SPECIFICATIONS:MAXIMUM SINGLE – 4’0” (1219) W X 9’-0” (2743) HMAXIMUM PAIR – 8’0” (2438) W X 9’0” (2743) H (NO DOUBLE EGRESS)THROAT – 3-3/4” (95) MIN TO 13” (330) MAX 3F ONLY.SINGLE AND DOUBLE RABBET ONLY (NO KERF)GAUGE: 16 GA. (1.5) MIN, 14 GA (1.8) MAX MATERIAL: COLD ROLLED OR GALVANNEALED STEELATTACHMENT HOLES: HOLES ON THE “NO RETURN” SIDE LOCATED AT 16” MAX SPACING AND 2” MAX FROM ENDS.

Page 140: CURRIES Tech Data Frame Section.pdf5 Masonry Face Flush KD Frame Cased Opening Frame Technical Data March, 2015 VARIES 3” (76.2) MINIMUM 1” (25.4) 1-1/4” (31.8) 1-1/2” (30.1)

137Drywall KD SideLight

Frame Technical DataMay, 2012

L

LAUQE

:SETON .SELIFORP EDISTUO NO NOITCURTSNOC DK.1

DETACOL EB OT ROHCNA NOISSERPMOC ARTXE.BMAJ THGILEDIS FO MOTTOB EHT TA

TA DAEH OT DEDLEW EB OT PURRITS NOILLUM.2.DERETNEC NOILLUM ROF HCTON

DEDLEW EB OT PILCTOOF DEDLEW ESREVER.3.AERA LLIS REDNU NOILLUM OT

HCTON POTS A SERIUQER NOILLUM LACITREV.4.POT TA

"Z" THGIL EDIS DK ROF DAEH NO HCTON ROF.5.)"521. - EZIS ECAF( HCTON

BASE ANCHORS

COMPRESSION ANCHORS

KNOCK DOWN (KD)CONNECTION

MULLIONSTIRRUP

STOPNOTCH

MULLION

HEAD

Z-NOTCH

MULLION

SILL

REVERSE WELDED FOOTCLIP

DRYWALL “C” PROFILE16 GAUGE ONLY2” FACE STANDARD – 1-1/2” AND 1-3/4” AVAILABLEJAMB DEPTHS – UNEQUAL RABBET - 4-1/2” THROUGH 8-3/4” EQUAL RABBET - 4-7/8” THROUGH 8-3/4”SILL FACE 1-1/2” THROUGH 6” AVAILABLECOMPRESSION ANCHORSBASE ANCHORS – 2” FACE HAS STANDARD BASE ANCHOR (PUNCH FACE) 1-1/2” AND 1-3/4” FACE HAS OPTIONAL BASE ANCHOR4’0” X 8’0” MAXIMUM DOOR OPENING8’0” X 8’0” MAXIMUM ELEVATION OPENING SIZEAVAILABLE IN SINGLE AND DOUBLE (SAME SIDE) SIDELIGHT NO HORIZONTAL MULLIONS ALLOWEDSINGLE DOOR OPENING ONLYNON-RATED ONLY

ROUGH OPENING REQUIREMENTS:THE ROUGH OPENING HEIGHT EQUALS THE FINISHED OPENING HEIGHT +1”.

THE ROUGH OPENING WIDTH EQUALS THE FINISHED WIDTH +2”.

Page 141: CURRIES Tech Data Frame Section.pdf5 Masonry Face Flush KD Frame Cased Opening Frame Technical Data March, 2015 VARIES 3” (76.2) MINIMUM 1” (25.4) 1-1/4” (31.8) 1-1/2” (30.1)

138ElectroLynx® System LX OptionsFrame Technical Data

The CURRIES LX cable is equipped with the ElectroLynx® System of “plug-in” connectors for fast, easy, connection to similarly equipped ASSA ABLOY Hardware. The LX cable has 15 conductors of 22 gauge wire in a PVC jacket, with ElectroLynx snap connectors on the hard-ware prep end only. Ship loose only. Power over Ethernet (PoE) cabels are also available.

– Check anchor interference with conduit, some loose anchor styles won’t work.– Some electric preps won’t allow 1/2” drywall penetration for fire rated frames.– Conduit is to be supplied and installed by others.

“Hardwiring Made Easy”

April, 2011