Water Treatment Concerns
Bio-growthScalingCorrosion
1 2 3 4 5 6 7 8 9 10 11 12 13 14
Corrosion Tendency Scaling Tendency
pH
Combating Micro-BiologicalsCombating Micro-Biologicals
BioClean 610 Biodegradable, coconut oil-
based phospholipid for preservation of system free of bio-growth starting at 300-600ppm
BioClean 612 Aliphatic amide based
organic penetrating agent for dispersion of bio-growth deposits/films starting at 50-100ppm
Combating Scaling
S-14, dosage starting at 10ppm
S-14F, dosage starting at 10ppm Meets requirements of 21CFR 173.310 for
use in boilers Meets requirements of 21CFR 176.170
and 176.180 for use in paper production applications
ANSI NSF standard 60 approval for potable water applications up to 10 ppm
S-14RO
Cortec’s H2O Products
Cortec has products for the following systems: Cooling Tower systems (open recirc. loops) Closed loop systems (heating/cooling; e.g. chillers, heat exchangers, water/glycol
loops) Boilers (low, medium, & high pressure) Miscellaneous:
HydrotestingSea WaterPickling processes, Lay-Up, & more
How VpCI Water Products Work
VpCI Water Additives
Reach the metal through
Vapor Phase Vapor/Liquid Phase
Liquid Phase
Film-forming mechanism of protection
High Performance of VCIs for H2O Treatment Confirmed
by:
Laboratory corrosion test at static and dynamic conditions
Electrochemical study
Application at the Cortec plant (cooling system for the extruder and a boiler)
Field results (Drew/Ashland, US Waters Services, Cortec’s cooling tower and boiler, etc.)
Immersion and Partial Immersion Corrosion Tests
ASTM G-316 Sanded and methanol cleaned metal panels
Immersed in containers filled with water-based solutions/electrolytes with or without added treatment (‘Control’)
Weight loss was determined or panels were visually evaluated for the presence of corrosion after cleaning according to ASTM G-1.7
Electrochemical Testing
Test Equipment: Potentiostat/Galvanostat “Versastat” with corrosion software model 352/252 SoftCorr™
Reference: Reference: SSCE SSCE
Calomel Calomel SaturatedSaturated
Counter: High-density Counter: High-density graphitegraphite
Working: Working: Z15001 Z15001
ZincZinc
Tests in Pilot Cooling TowerTests in Pilot Cooling Tower
Model 005 cooling tower manufactured by RSD Towers
16 GPM recirculation rate1.5 inch inlet and outlet diameters
Tap water with 2.3-2.5 cycles of concentration
Temperature = 45-50CpH = 8.6-8.8TDS = 1250-1300ppmConductivity = 1850-2000uS
Weight loss on corrosion coupons in contact with the tower water passing used to calculate corrosion rates
Toxicity Testing
Aquatic Toxicity Testing Terms
NOEC = Highest Concentration with No Observable Effect
LOEC = Lowest Concentration with an Observable Effect
LC50 = Lethal Concentration in the water for 50% of the population tested in the test period
IC25 = It is the level at which the organisms exhibit 25 percent reduction in a biological measurement such as reproduction or growth. It is calculated statistically and used in chronic toxicity testing.
LD50 = Lethal Dose (based on body weight of species tested) for 50% of the population tested
Boilers and Steam Line Products
Low/Medium Pressure working Boilers:
VpCI-617 (USDA approved), VpCI-615S-10/S-10F (Corrosion inhibitor for steam condensate lines
in the boiler system). S-7 Oxygen scavenger
High Pressure BoilersS-15 Blend of VpCI, CCI, and Oxygen
Scavenger
Cooling System Problems
Left Unchecked Can Cause:
Loss of Heat Transfer Increased Energy (Resources) UseReduced Equipment Life / FailuresLost Production / Profits Increased Maintenance CostsPotential Safety / Health HarmSystem / Plant Shutdown
VpCIs for Closed LoopRe-circulating Systems
Same water is used over and over, new chemicals and minerals are
not added to system as often
VpCIs for Closed LoopRe-circulating Systems
VpCI-649, VpCI-649 P
Sodium Molybdate tracer
Metals: Ferrous, Copper & Brass, Aluminum & alloys, Galvanized
Chemistry: Vapor & contact film-forming inhibitor; aminocarboxylate-based salts & polyacrylate dispersant/anti-scalant
Building Blocks for Water Treatment formulations
S-69 (liquid) and S-69 P
Building block for formulations
sodium molybdate as a tracer
Enhances corrosion inhibition for blended products for open loop & closed loop
systems
A good VpCI & CCI package
Detecting ConcentrationApproximate Concentration of Molybdate vs VpCI-649
0
10
20
30
40
5060
70
80
90
100
0 0.2 0.4 0.6 0.8 1 1.2
wt % VpCI-649
mg
/l m
oly
bd
ate
http://www.hach.comMolybdate Test Kit, Model MO-2, Color Disc, 100
tests Range (0-50 mg/L) Product #: 1419301
VpCIs for Open Systems
As new water is continually added, new minerals are also added. New
chemical must also be added.
VpCI for Once-through andRe-circulating Open Loop Cooling
VpCI-647 Concentration Level: 100-200 PPM
initial dosage. Maintenance dosage: 15-50 PPM
S-14 Bio Concentration Level: Added to the
make-up water at the rate 20-50 ppm. S-14 Bio is effective at a pH range of 6.0-9.0.
Metals: Ferrous, Copper, Brass, Aluminum, & Galvanized steel
Chemistry: Vapor and contact film-forming inhibitors along with anti-scalants
Concentration DeterminationConcentration Determination
Concentration of VpCI-647
Measured Concentration of Organophosphonates
50ppm 9ppm
100ppm 20ppm
200ppm 38ppm
250ppm 49ppm
300ppm 52ppm
http://www.wet-international.com Kit # K-0142/1http://www.hach.com Kit # 224800Phosphorus, Orthophosphate (reactive) Test Kit, Model PO-19, Color Disc, 100 tests http://chemetrics.com Kit # 8510D
Water/Glycol Systems
M-640 L/ M-640/M-95 Protective concentration levels
M-640 L, M-95: 2.0 – 2.5% by weight M-640: 0.5% by weight
Protects cast iron, carbon steel, copper, brass, solder and aluminum
Passes ASTM D 1389 test method for automotive coolants
VACUettesVACUettesauto-dilution ampoulesauto-dilution ampoules
Step 1. Hold the ampoule horizontally
and touch the tip of the capillary to the sample
to automatically fill.
Step 2. Fill the snap cup with diluent and immerse
the ampoule/capillary tube assembly. Snap the tip.
The ampoule will fill with the diluted sample.
Step 3. A bubble of gas will appear. Tilt the ampoule several times,
allowing the bubble to travel from
end to end.
Step 4. When color develops, quantify the results with a
color comparator.
www.chemetrics.com
TDS – Total Dissolved Solids (ppm, mg/l)
Conductivity (S, mhos)
Iron, Copper, Calcium, Hardness
Test MethodsTest Methods
Cortec Water Cortec Water Treatment Products for Treatment Products for
Lay-Up ApplicationsLay-Up Applications
Boiler LizardTM
Ferrous metal protectionBio-degradable, non-toxic, & non-irritatingBoiler Dry Lay-Up
Dry Lay-up Dosage: 1 bag per 1,000 gallons of total capacity (or, 3.8m3 or 134 ft3)
Boiler Lay-Up
Boiler Lay-Up : Conventional Vs VpCIs
Silica gels are hard to use and their removal before start up adds another laborious operation.
Nitrogen Blankets require extremely tight seals, & often onsite generators.
Hydrazine, a suspected carcinogen, is very hazardous.
VpCI products in easy to use water soluble bags.
Environmentally sound (100% biodegradable).
Protects boiler internals; including hard to reach places, through vapor phase.
No removal necessary for typical start-ups.
Replaces O2 scavenger
Cortec’s VpCI In Cooling Tower Lay-up
Cooling Loop GatorCooling Loop GatorTMTM
Multi-metal protection including galvanized
Non-toxic, & non-irritating Wet lay-up & flushing applications
4 bags/carton 1 carton/ 1000 gallons (4000 liters,
4m3)
Cooling Tower Lay-Up :Conventional Vs VpCIs
Strictly CCIs. Hazardous to environment Oil products react with
rubbers in the system & roof tars.
Promotes microbial growth during the lay-up period & even after start up
VpCIs tandem with CCIs Bio-degradable,
environmentally friendly Safe for wide spectrum of
rubbers and elastomers. Do not promote microbial
growth.
Cooling Tower Lay-Up :Conventional Vs VpCIs
Oil based products do not apply evenly & forms gunk balls in Heat Transfer equipment
Need expensive cleaners along with biocides to remove oil films before start-ups
Easy applicationNo removal
needed for a typical start-up
Cooling Tower Lay-up
Competitive products:Nalco 2572, 41 L, and other oil based products, a few other contact corrosion products
Easy methods of application with VpCIs: Add required dosage to the tower make up water
or basin. 4bags (1 box) treats up to 1,000gallons Circulate for 12 to 24 hours (bags and product
dissolves and treats system internals) Drain water to desired level, and seal off pipe
valves to external atmosphere. Lay-Up is complete!
Cortec Water Cortec Water Treatment Products for Treatment Products for
Niche and Niche and Miscellaneous Apps.Miscellaneous Apps.
Pickling Process (acid cleaning)
S-11 / S-11Org /S-11 Powder
S-11 for mineral acids such as; nitric, hydrochloric, sulfuric, etc… Used at 0.5% - 1.0% by weight in final concentration.
S-11 Org for organic acids such as; acetic, citric, formic, oxalic, and also inorganic phosphoric, sulfuric, sulfamic. Used at 1.0 – 4.0% final concentration
S-11 Powder for sulfamic acid. Used at 1-4% final concentration.
Salt Water/Brine
VpCI-644 & VpCI-645
VpCI-644=0.1-0.3% by weight protective concentration
Strong film-forming properties, & vapor phase protection for difficult situations
VpCI-645=0.25-0.75% by weight concentration
Environmentally friendly option for less aggressive applications.
Salt Water/Brine
M-605 designed to suppress corrosion caused by NaCl based deicer.
M-605 L especially effective when added to a MgCl2 based deicer
M-605 PS effective in CaCl2 based deicer
As a deicing salt additive, 4-5% by weight As an inhibitor to brines in closed loop
cooling systems, (3000-5000 ppm / 0.3-0.5 % weight)
Salt Water
M-645 “Float Coat” Product Perfect for;
Ballast Tank ProtectionSalt Water Hydrotesting, or storage
Approved by EPA for discharge into seawater
Used at 0.15-0.3% as a float coat, or 1,300 – 1,900 sq ft/gallon surface applied
VpCI-641, M-645, VpCI-609, S-69/S-69P, VpCI-377, VpCI-417P, VpCI-644, VpCI-645
Multiple Products, for multiple different applications. Depending upon length of protection needed, metal types (ferrous, copper, brass, cast iron, etc…) see hydrotesting chart for more information
Hydro-testing