copper-lx-sx-ew
TRANSCRIPT
Copper Lx-Sx-EwManufacturing Process
V00672/01 (10.2000) Copyright © Sulzer Pumps Finland Oy
General Flowsheet of Process
Leaching
Solvent extractionextraction stage
Solvent extractionwashing stage
Solvent extractionstripping stage
Electrowinning
Copper cathodes
Pregnant leach solution
Loaded organic
Washed loaded organic
Advance electrolyteSpent electrolyte
Unloaded organic
Raffinate solution
OresSulphuric acid
Water
Copper Lx-Sx-EwManufacturing Process
V00672/02 (10.2000) Copyright © Sulzer Pumps Finland Oy
H O2 H O2
Pregnant solution tosolvent extraction
SX
SX
SX
SX
H O2
H O2
H O2
H SO2 4 H SO2 4H SO2 4
RF-tanks
H SO2 4
H SO2 4
5.APP/T
5.APP/T5.APP/T 5.APP/T
4.APP/T
5.APP/T
2.APP/T 2.APP/T
1.APP/T
1.APP/T1.APP/T2.APP/T
3.APP/T 3.APP/T 3.APP/T
6.APP/T
6.APP/T6.APP/T 6.APP/T
6.APP/T
Autoclave Dump leaching
Truck
Oreslow grade and semi-waste
Broken ores Low and medium grade Crushing
Agglomeration
Loading
Heap leaching
PLS Tank
ILS Tank ILS Tank ILS Tank
RF Tank RF Tank RF Tank
PLS Tank PLS Tank
Pumps in Leaching Process (Lx)
1 2 Liquid pH Copper Temp. Density Typical Pump Impeller Seal type Material Dutyo o 3 content g/l ( C, F) (kg/m , head type type
3 lb/ft ) m, ft
Pregnant leach solution, H SO 1-5 g/l2 4
APP/T Closed
Closed
Closed
Closed
Dyn. (DS01)/Double mech.(MR22)
Dyn. (DS01)/Double mech.(MR22)
Dyn. (DS01)/Double mech.(MR22)
Dyn. (DS01)/Double mech.(MR22)
Single mech.(MR02)
Dynamic(DS01)
A890 3A
A890 3A
A890 3A
A890 3A
A890 3A
A890 3A
PLS to SX,from PLS pond
ILS to leach,from ILS pond
RF to leach,from RF pond
RF to RF pond,from SX
Process andmake-up water
Process and make-up sulfuric acid
3.0 - 7.01-2
1
<1
<1
<1
~7
10 - 20/50 - 68
1150/72
1150/72
5 - 20/16 - 66
5 - 20/16 - 66
5 - 20/16 - 66
1 - 20/3 - 66
1 - 103 - 33
1 - 10/3 - 33
1100/69
1100/69
1830/114
1000/63
10 - 20/50 - 68
10 - 20/50 - 68
15 - 20/59 - 68
10 - 20/50 - 68
10 - 20/50 - 68
1.0 - 2.0
0.2 - 0.8
0.5 - 1.0
–
–
1) Dissolved2) Material recommendation is only for specified application
1
Intermediate leach solution, H SO 7-12 g/l2 4
Raffinate solution,H SO 10-15 g/l2 4
Raffinate solution,H SO 10-15 g/l2 4
Sulfuric acid,H SO 93-95%2 4
Process water
APP/T
APP/T
APP/T
APP/T
APP/T
Closed
Closed
2
3
4
5
6
Copper Lx-Sx-Ew Manufacturing Process
V00672/03 (10.2000) Copyright © Sulzer Pumps Finland Oy 28
Pumps in Leaching Process (Lx)
Copper Lx-Sx-EwManufacturing Process
V00672/04 (10.2000) Copyright © Sulzer Pumps Finland Oy
2.APP/T
1.APP/T
10.APP/T
8.APP/T
11.APP/T
9.APP/T
10.APP/T
4.APP/T
3.APP/T
5.APP/T
6.APP/T
7.APP/T
RF Tank
Leaching
Extraction
RF
RF
Spentelectrolyte
Stripping
Washed loadedorganic tank
Wash watertank
Make-up
Water toRF tanks
Leaching
Washing
Advanceelectrolyte
to electrowinning
RF
Pregnant leach solutionfrom leaching
RF AfterSettler
Crudtank
Pumps in Solvent Extraction Process (Sx)
FreshKerosene
1 2 Liquid pH Copper Temp. Density Typical Pump Impeller Seal type Material Dutyo o 3 g/l ( C, F) (kg/m , head type type
3 lb/ft ) m, ft
1) Dissolved2) Material recommendation is only for specified application
Kerosene APP/T Open Double mech.(MR20)
A890 3A Organicremoval
1.0 - 2.07 15 - 20/59 - 68
900/56
1 - 5/3 - 16
2
Raffinate solution,H SO 10-15 g/l2 4
APP/T Closed Dyn. (DS01)/Double mech.(MR22)
A890 3A RF to RF pond ,from SX
0.5 - 1.0<1 10 - 20/50 - 68
1100/69
1 - 20/3 - 66
3
Wash water,H SO <45 g/l2 4
APP/T Closed Dynamic seal(DS01)
A890 3A Wash water towashing stage
–<1 15 - 20/59 - 68
1000/62
1 - 5/3 - 16
4
Demineralizated water APP/T Closed A890 3A Deminer. waterto wash water tank
–7 15 - 20/59 - 68
1000/62
1 - 5/3 - 16
5
Sulfuric acid,H SO 93-95% g/l2 4
APP/T Closed A890 3A Processsulfuric acid
–<1 15 - 20/59 - 68
1830/114
1 - 5/3 - 16
6
Electrolyte bleed,H SO 165-175 g/l2 4
APP/T Closed Dyn. (DS01)/Double mech.(MR22)
A890 3A Electrolyte bleedto wash water tank
30 - 35<1 15 - 20/59 - 68
1200/75
1 - 10/3 - 33
7
Kerosene APP/T Open Double mech.(Mr20)
A890 3A Loaded organicto stripping stage
5.0 - 8.07 15 - 20/59 - 68
850/53
1 - 5/3 - 16
8
Advance electrolyte,H SO 140-150 g/l2 4
APP/T Closed Dyn. (DS01)/Double mech.(MR22)
A890 1B Advance electrolyteto EW, from SX
45 - 55<1 40 - 50/104 -122
1200/75
1 - 10/3 - 33
9
Crud APP/T Closed A890 3A Crud to crudtreatment system
–7 15 - 20/59 - 68
850/53
1 - 5/3 - 16
0 1
11 Spent electrolyte,H SO 165-175 g/l2 4
APP/T Closed A890 1B Spent electrolyteto SX, from EW
30 - 40<1 40 - 50/104 -122
1200/75
1 - 10/3 - 33
Pregnant leach solution, H SO 1-5 g/l2 4
APP/T Closed Dyn. (Ds01)/Double mech.(MR22)
A890 3A PLS to SX,from PLS pond
3.0 - 7.01-2 10 - 20/50 - 68
1150/72
5 - 20/16 - 66
1
Copper Lx-Sx-Ew Manufacturing Process
V00672/05 (10.2000) Copyright © Sulzer Pumps Finland Oy 30
Pumps in Solvent Extraction Process (Sx)
Dynamic seal(DS01)
Dyn. (DS01)/Double mech.(MR22)
Dyn. (DS01)/Double mech.(MR22)
Dyn. (DS01)/Double mech.(MR22)Dyn. (DS01)/Double mech.(MR22)
Copper Lx-Sx-EwManufacturing Process
V00672/06 (10.2000) Copyright © Sulzer Pumps Finland Oy
Extraction
Cathodes
Cathodes
Advance electrolytefrom extraction
Extraction
1.APP/T
2.APP/T
2.APP/T
3.APP/T 4.APP/T
5.APP/TExtraction
Flotation
Electrowinning
Electrolytetank
Electrowinning
Heatexchanging
SteamCondensate
ExtractionLeaching
+ –
+ –
Pumps in Electrowinning Process (Ew)
Copper Lx-Sx-Ew Manufacturing Process
V00672/07 (10.2000) Copyright © Sulzer Pumps Finland Oy 32
1 2 Liquid pH Copper Temp. Density Typical Pump Impeller Seal type Material Dutyo o 3 content g/l ( C, F) (kg/m , head type type
3 lb/ft ) m, ft
Advance electro-lyte, H SO 140-150 g/l2 4
APP/T Closed
Closed
Closed
Closed
Dyn (DS01)/Double mech.(MR22)
Doublemechanical(MR20)
Dyn (DS01)/Double mech.(MR22)
Dyn. (DS01)/Double mech.(MR22)
A890 1B
A890 3A
A890 3A
A890 1B
A890 1B
Advance electro-lyte to EW,from SX
Organic removalto SX
Electrolyte bleedto wash watertank
Spent electrolyteto SX, from EW
Electrolyte tocommercial cells
45 - 55<1
7
<1
<1
<1
40 - 50/104-122
1200/75
850/53
1 -10/3 - 33
1 - 5/3 - 16
1 -10/3 - 33
1 - 10/3 - 33
1 - 5/3 - 16
1200/75
1200/75
1200/75
15 - 20/59-68
15 - 20/59-68
40 - 50/104-122
40 - 50/104-122
5.0 - 8.0
30 - 35
30 - 40
35 - 40
1) Dissolved2) Material recommendation is only for specified application3) The floating installation of the pumps in Electrowinning process
1
Kerosene
Electrolyte bleed,H SO 165-175 g/l2 4
Spent electrolyte,H SO 165-175 g/l2 4
electrolyte,H SO 160-170 g/l2 4
APP/T
APP/T
APP/T
APP/T Closed
2
3
4
5
Pumps in Electrowinning Process (Ew)
Dyn. (DS01)/Double mech.(MR22)