coldstorage - gaf
TRANSCRIPT
EVERGUARD
®
TPO UTILITY
FLASHING MEMBRANE (TPO
ONLY) OR MIN. 8" (203 mm) WIDE
REINFORCED EVERGUARD
®
MEMBRANE
HEAT WELD ON BOTH ENDS
ROOF DECK/SUBSTRATE
FOAM FILLED POCKET MIN 1"
(25.4 mm) OR AS SPECIFIED
8" (203 mm) MIN. 8" (203 mm) MIN.
DRILL-TEC
™
PLATES &
FASTENERS 12" (305 mm) O.C.
DRILL-TEC
™
FASTENER AND
ANCHOR BAR 6" (152 mm) O.C.
WARM COLD
METAL CAP (OPTIONAL)
MULTIPLE LAYERS OF
ENERGYGUARD
™
ROOF
INSULATION, STAGGERED
AND OFFSET
®
EVERGUARD
®
WATER BLOCK
EVERGUARD
®
BONDING ADHESIVE
ISSUE / REVISION DATEDRAWING #
GAF ●
1 Campus Drive Parsippany, NJ 07054 ● www.gaf.com ● [email protected] ● 800-766-3411
LEGEND
SCALE
N.T.S.
THIS DETAIL APPLIES TO:
ColdStorage
3/1/21
SINGLE-PLY: TPO & PVC 60-80 mil membranes
130A
COLD TO WARM TRANSITION TIE-IN
ADHERED SYSTEMS
MECHANICALLY ATTACHED SYSTEMS
RHINOBOND SYSTEMS
1. FOR STEEL ROOF DECKS: FILL STEEL DECK FLUTES WITH SPRAY FOAM INSULATION PRIOR TO THE INSTALLATION OF
ABOVE DECK INSULATION A MINIMUM OF 12 INCHES (305 mm) FROM FACE OF WALL ON EACH SIDE, BOTH SIDES OF WALL.
NOTE:
EVERGUARD
®
TPO UTILITY
FLASHING MEMBRANE (TPO
ONLY) OR MIN. 8" (203 mm)
REINFORCED EVERGUARD
®
MEMBRANE
HEAT-WELDED LAP
ON BOTH ENDS
ROOF DECK/SUBSTRATE
FOAM FILLED POCKET MIN 1"
(25.4 mm) OR AS SPECIFIED
DRILL-TEC
™
PLATES &
FASTENERS 12" (305 mm) O.C.
WARM COLD
METAL PANEL CAP
(BY OTHERS)
MULTIPLE LAYERS OF
ENERGYGUARD
™
ROOF
INSULATION, STAGGERED
AND OFFSET
®
EVERGUARD
®
WATER BLOCK
ISSUE / REVISION DATEDRAWING #
GAF ●
1 Campus Drive Parsippany, NJ 07054 ● www.gaf.com ● [email protected] ● 800-766-3411
LEGEND
SCALE
N.T.S.
THIS DETAIL APPLIES TO:
ColdStorage
3/1/21
SINGLE-PLY: TPO & PVC 60-80 mil membranes
130B
COLD TO WARM TRANSITION TIE-IN WITH INSULATED
METAL PANEL ABOVE ROOF DECK
ADHERED SYSTEMS
MECHANICALLY ATTACHED SYSTEMS
RHINOBOND SYSTEMS
INSULATED METAL PANEL
MIN. 4" (102 mm)
HEAT-WELDED
EVERGUARD
®
BONDING ADHESIVE
MIN. 4" (102 mm)
NOTE:
1. FOR STEEL ROOF DECKS: FILL STEEL DECK FLUTES WITH SPRAY FOAM INSULATION PRIOR TO THE INSTALLATION OF
ABOVE DECK INSULATION A MINIMUM OF 12 INCHES (305 mm) FROM FACE OF WALL, BOTH SIDES OF WALL.
2. AIR SEAL WALL-TO-ROOF DECK INTERFACE.
DRILL-TEC
™
FASTENER AND
ANCHOR BAR 6" (152 mm) O.C.
EVERGUARD
®
WATER BLOCK
THERMAL CUT IN PANEL SKIN
REINFORCED EVERGUARD
®
MEMBRANE
MULTIPLE LAYERS OF ENERGYGUARD
™
ROOF INSULATION, STAGGERED AND
OFFSET
®
ISSUE / REVISION DATEDRAWING #
GAF ●
1 Campus Drive Parsippany, NJ 07054 ● www.gaf.com ● [email protected] ● 800-766-3411
LEGEND
SCALE
N.T.S.
THIS DETAIL APPLIES TO:
ColdStorage
3/1/21
SINGLE-PLY: TPO & PVC 60-80 mil membranes
130C
COLD TO WARM TRANSITION TIE-IN WITH WALL BELOW
ROOF DECK
ADHERED SYSTEMS
MECHANICALLY ATTACHED SYSTEMS
RHINOBOND SYSTEMS
SEAL MEMBRANE TO ROOF DECK
WITH APPROPRIATE ADHESIVE
INSULATED METAL PANEL
WARM COLD
MIN. 6" (152 mm) MIN. 6" (152 mm)
ROOF DECK/SUBSTRATE
HEAT-WELDED
EVERGUARD
®
BONDING ADHESIVE
NOTE:
1. FOR STEEL ROOF DECKS: FILL STEEL DECK FLUTES WITH SPRAY FOAM INSULATION PRIOR TO THE INSTALLATION OF
ABOVE DECK INSULATION A MINIMUM OF 12 INCHES (305 mm) FROM FACE OF WALL ON EACH SIDE, BOTH SIDES OF WALL.
2. AIR SEAL WALL-TO-ROOF DECK INTERFACE PER ARCHITECTURAL DRAWINGS.
HEAT-WELDED LAP
WALL TO ROOF DECK INTERFACE PER
PANEL MANUFACTURER INSTRUCTIONS
REINFORCED EVERGUARD
®
MEMBRANE
ROOF DECK/SUBSTRATE
FOAM FILLED POCKET MIN 1"
(25.4 mm) OR AS SPECIFIED
DRILL-TEC
™
PLATES & FASTENERS
12" (305 mm) O.C.
WARM COLD
METAL PANEL CAP (BY OTHERS)
MULTIPLE LAYERS OF
ENERGYGUARD
™
ROOF
INSULATION, STAGGERED
AND OFFSET
®
EVERGUARD
®
WATER BLOCK
ISSUE / REVISION DATEDRAWING #
GAF ●
1 Campus Drive Parsippany, NJ 07054 ● www.gaf.com ● [email protected] ● 800-766-3411
LEGEND
SCALE
N.T.S.
THIS DETAIL APPLIES TO:
ColdStorage
3/15/21
SINGLE-PLY: TPO & PVC 60-80 mil membranes
130D
COLD TO WARM TRANSITION TIE-IN WITH INSULATED METAL
PANEL ABOVE ROOF DECK - OFFSET IN ROOF LEVELS DETAIL
ADHERED SYSTEMS
MECHANICALLY ATTACHED SYSTEMS
RHINOBOND SYSTEMS
INSULATED METAL PANEL
HEAT-WELDED
EVERGUARD
®
BONDING ADHESIVE
NOTE:
1. FOR STEEL ROOF DECKS: FILL STEEL DECK FLUTES WITH SPRAY FOAM INSULATION PRIOR TO THE INSTALLATION OF
ABOVE DECK INSULATION A MINIMUM OF 12 INCHES (305 mm) FROM FACE OF WALL, BOTH SIDES OF WALL.
2. AIR SEAL WALL-TO-ROOF DECK INTERFACE.
DRILL-TEC
™
FASTENER AND
ANCHOR BAR 6" (152 mm) O.C.
EVERGUARD
®
WATER BLOCK
THERMAL CUT IN PANEL SKIN
HEAT-WELDED LAP ON BOTH ENDS
REINFORCED EVERGUARD
®
MEMBRANE
MIN. 6" (152 mm)MIN. 6" (152 mm)
EVERGUARD
®
TPO UTILITY
FLASHING MEMBRANE (TPO
ONLY) OR MIN. 8" (203 mm)
WIDE REINFORCED
EVERGUARD
®
MEMBRANE
REINFORCED EVERGUARD
®
MEMBRANE
WOOD NAILER MIN 2" X _"
WALL
FOAM FILLED POCKET MIN. 1"
(25.4 mm) OR AS SPECIFIED
ROOF DECK/SUBSTRATE
EVERGUARD
®
COATED
METAL EDGE, SEE NOTE 1
MULTIPLE LAYERS OF
ENERGYGUARD
™
ROOF INSULATION,
STAGGERED AND OFFSET
®
HEAT-WELDED
EVERGUARD
®
WATER-BLOCK
ISSUE / REVISION DATEDRAWING #
GAF ●
1 Campus Drive Parsippany, NJ 07054 ● www.gaf.com ● [email protected] ● 800-766-3411
LEGEND
SCALE
N.T.S.
THIS DETAIL APPLIES TO:
ColdStorage
3/1/21
SINGLE-PLY: TPO & PVC 60-80 mil membranes
201A
COATED METAL ROOF EDGE
ADHERED SYSTEMS
MECHANICALLY ATTACHED SYSTEMS
RHINOBOND SYSTEMS
NOTE:
1. METAL EDGE SHOULD BE DESIGNED FOR WIND RESISTANCE IN ACCORDANCE WITH THE APPLICABLE EDITION OF ASCE 7 AND
TESTED FOR CAPACITY IN ACCORDANCE WITH THE TEST METHODS IN THE APPLICABLE EDITION OF ANSI/SPRI ES-1.
2. FOR STEEL ROOF DECKS: FILL STEEL DECK FLUTES WITH SPRAY FOAM INSULATION PRIOR TO THE INSTALLATION OF ABOVE
DECK INSULATION A MINIMUM OF 12 INCHES (305 mm) FROM FACE OF WALL.
EVERGUARD
®
TPO UTILITY FLASHING
MEMBRANE (TPO ONLY) OR MIN. 8" (203 mm)
WIDE REINFORCED EVERGUARD
®
MEMBRANE
REINFORCED EVERGUARD
®
MEMBRANE
INSULATED WALL PANEL
FOAM FILLED POCKET MIN. 1"
(25.4 mm) OR AS SPECIFIED
ROOF DECK/SUBSTRATE
EVERGUARD
®
COATED
METAL EDGE, SEE NOTE 1
MULTIPLE LAYERS OF
ENERGYGUARD
™
ROOF INSULATION,
STAGGERED AND OFFSET
®
HEAT-WELDED
EVERGUARD
®
WATER-BLOCK
ISSUE / REVISION DATEDRAWING #
GAF ●
1 Campus Drive Parsippany, NJ 07054 ● www.gaf.com ● [email protected] ● 800-766-3411
LEGEND
SCALE
N.T.S.
THIS DETAIL APPLIES TO:
ColdStorage
3/1/21
SINGLE-PLY: TPO & PVC 60-80 mil membranes
201C
COATED METAL ROOF EDGE AT INSULATED WALL PANEL
ADHERED SYSTEMS
MECHANICALLY ATTACHED SYSTEMS
RHINOBOND SYSTEMS
METAL PANEL CAP
(BY OTHERS)
NOTE:
1. PERIMETER EDGE METAL SHOULD BE DESIGNED FOR WIND RESISTANCE IN ACCORDANCE WITH THE APPLICABLE EDITION OF
ASCE 7 AND TESTED FOR CAPACITY IN ACCORDANCE WITH THE TEST METHODS IN THE APPLICABLE EDITION OF ANSI/SPRI ES-1.
2. THE ATTACHMENT CAPACITY OF THE INSULATED METAL PANELS SHOULD BE VERIFIED.
3. FOR STEEL ROOF DECKS: FILL STEEL DECK FLUTES WITH SPRAY FOAM INSULATION PRIOR TO THE INSTALLATION OF ABOVE
DECK INSULATION A MINIMUM OF 12 INCHES (305 mm) FROM FACE OF WALL.
EVERGUARD
®
WATER BLOCK
HEAT-WELDED LAP ON
BOTH ENDS
THERMAL CUT IN PANEL SKIN
WOOD NAILER MIN 2" X _"
EVERGUARD
®
COATED METAL
GRAVEL STOP WITH HEMMED
EDGE, SEE NOTE 1
GALVANIZED ANGULAR RING
SHANK NAIL @ 4" (102 mm) O.C.
STAGGERED OR DRILL-TEC
™
FASTENERS 12" (305 mm) O.C.
EVERGUARD
®
TPO UTILITY
FLASHING MEMBRANE (TPO
ONLY) OR MIN. 8" (203 mm)
WIDE REINFORCED
EVERGUARD
®
MEMBRANE
REINFORCED EVERGUARD
®
MEMBRANE
FOAM FILLED POCKET MIN. 1"
(25.4 mm) OR AS SPECIFIED
ROOF DECK/SUBSTRATE
MULTIPLE LAYERS OF
ENERGYGUARD
™
ROOF INSULATION,
STAGGERED AND OFFSET
®
HEAT-WELDED
EVERGUARD
®
WATER-BLOCK
ISSUE / REVISION DATEDRAWING #
GAF ●
1 Campus Drive Parsippany, NJ 07054 ● www.gaf.com ● [email protected] ● 800-766-3411
LEGEND
SCALE
N.T.S.
THIS DETAIL APPLIES TO:
ColdStorage
3/1/21
SINGLE-PLY: TPO & PVC 60-80 mil membranes
202B
COATED METAL GRAVEL STOP AT ROOF EDGE
ADHERED SYSTEMS
MECHANICALLY ATTACHED SYSTEMS
RHINOBOND SYSTEMS
1. METAL GRAVEL STOP SHOULD BE DESIGNED FOR WIND RESISTANCE IN ACCORDANCE WITH THE APPLICABLE EDITION OF ASCE 7
AND TESTED FOR CAPACITY IN ACCORDANCE WITH THE TEST METHODS IN THE APPLICABLE EDITION OF ANSI/SPRI ES-1.
2. FOR STEEL ROOF DECKS: FILL STEEL DECK FLUTES WITH SPRAY FOAM INSULATION PRIOR TO THE INSTALLATION OF ABOVE DECK
INSULATION A MINIMUM OF 12 INCHES (305 mm) FROM FACE OF WALL.
3. AIR SEAL WALL-TO-ROOF DECK INTERFACE.
NOTE:
WOOD NAILER MIN 2" X _"
METAL GRAVEL STOP WITH
HEMMED EDGE, SEE NOTE 2
GALVANIZED ANGULAR RING
SHANK NAIL @ 4" (102 mm) O.C.
STAGGERED OR DRILL-TEC
™
FASTENERS 12" (305 mm) O.C.
EVERGUARD
®
TPO COVER TAPE
REINFORCED EVERGUARD
®
MEMBRANE
FOAM FILLED POCKET MIN. 1"
(25.4 mm) OR AS SPECIFIED
ROOF DECK/SUBSTRATE
MULTIPLE LAYERS OF
ENERGYGUARD
™
ROOF INSULATION,
STAGGERED AND OFFSET
CONTINUOUS BEAD OF
FLEXSEAL
TM
CAULK GRADE
SEALANT.
®
EVERGUARD
®
WATER-BLOCKISSUE / REVISION DATEDRAWING #
GAF ●
1 Campus Drive Parsippany, NJ 07054 ● www.gaf.com ● [email protected] ● 800-766-3411
LEGEND
SCALE
N.T.S.
THIS DETAIL APPLIES TO:
ColdStorage
3/1/21
SINGLE-PLY: TPO & PVC 60-80 mil membranes
202C
METAL GRAVEL STOP WITH HEMMED EDGE
ADHERED SYSTEMS
MECHANICALLY ATTACHED SYSTEMS
RHINOBOND SYSTEMS
NOTE:
1. CLEAN METAL AND MEMBRANE WITH EVERGUARD
Ò TPO SEAM CLEANER AND ALLOW TO DRY. ONCE DRY, PRIME METAL AND
MEMBRANE WITH EVERGUARD
Ò TPO PRIMER BEFORE INSTALLING EVERGUARD
Ò TPO COVER TAPE.
2. METAL GRAVEL STOP SHOULD BE DESIGNED FOR WIND RESISTANCE IN ACCORDANCE WITH THE APPLICABLE EDITION OF
ASCE 7 AND TESTED FOR CAPACITY IN ACCORDANCE WITH THE TEST METHODS IN THE APPLICABLE EDITION OF ANSI/SPRI ES-1.
3. FOR STEEL ROOF DECKS: FILL STEEL DECK FLUTES WITH SPRAY FOAM INSULATION PRIOR TO THE INSTALLATION OF ABOVE
DECK INSULATION A MINIMUM OF 12 INCHES (305 mm) FROM FACE OF WALL.
EVERGUARD
®
WATER BLOCK
EVERGUARD
®
COATED METAL
GRAVEL STOP WITH HEMMED
EDGE, SEE NOTE 1
EVERGUARD
®
TPO UTILITY FLASHING
MEMBRANE (TPO ONLY) OR MIN. 8" (203 mm)
WIDE REINFORCED EVERGUARD
®
MEMBRANE
REINFORCED EVERGUARD
®
MEMBRANE
FOAM FILLED POCKET MIN. 1"
(25.4 mm) OR AS SPECIFIED
ROOF DECK/SUBSTRATE
MULTIPLE LAYERS OF
ENERGYGUARD
™
ROOF INSULATION,
STAGGERED AND OFFSET
®
HEAT-WELDED
EVERGUARD
®
WATER-BLOCK
ISSUE / REVISION DATEDRAWING #
GAF ●
1 Campus Drive Parsippany, NJ 07054 ● www.gaf.com ● [email protected] ● 800-766-3411
LEGEND
SCALE
N.T.S.
THIS DETAIL APPLIES TO:
ColdStorage
3/1/21
SINGLE-PLY: TPO & PVC 60-80 mil membranes
202D
COATED METAL GRAVEL STOP AT ROOF EDGE AT
INSULATED METAL PANELS
ADHERED SYSTEMS
MECHANICALLY ATTACHED SYSTEMS
RHINOBOND SYSTEMS
INSULATED METAL PANEL
METAL PANEL CAP
(BY OTHERS)
NOTE:
1. PERIMETER EDGE METAL SHOULD BE DESIGNED FOR WIND RESISTANCE IN ACCORDANCE WITH THE APPLICABLE EDITION OF
ASCE 7 AND TESTED FOR CAPACITY IN ACCORDANCE WITH THE TEST METHODS IN THE APPLICABLE EDITION OF ANSI/SPRI ES-1.
2. THE ATTACHMENT CAPACITY OF THE INSULATED METAL PANELS SHOULD BE VERIFIED.
3. FOR STEEL ROOF DECKS: FILL STEEL DECK FLUTES WITH SPRAY FOAM INSULATION PRIOR TO THE INSTALLATION OF ABOVE
DECK INSULATION A MINIMUM OF 12 INCHES (305 mm) FROM FACE OF WALL.
EVERGUARD
®
WATER BLOCK
HEAT-WELDED LAP ON
BOTH ENDS
THERMAL CUT IN PANEL SKIN
METAL GRAVEL STOP WITH
HEMMED EDGE, SEE NOTE 2
EVERGUARD
®
TPO COVER
TAPE
REINFORCED EVERGUARD
®
MEMBRANE
FOAM FILLED POCKET MIN. 1"
(25.4 mm) OR AS SPECIFIED
ROOF DECK/SUBSTRATE
MULTIPLE LAYERS OF
ENERGYGUARD
™
ROOF INSULATION,
STAGGERED AND OFFSET
NOTE:
1. CLEAN METAL AND MEMBRANE WITH EVERGUARD
Ò TPO SEAM CLEANER AND ALLOW TO DRY. ONCE DRY, PRIME METAL AND
MEMBRANE WITH EVERGUARD
Ò TPO PRIMER BEFORE INSTALLING EVERGUARD
Ò TPO COVER TAPE.
2. PERIMETER EDGE METAL SHOULD BE DESIGNED FOR WIND RESISTANCE IN ACCORDANCE WITH THE APPLICABLE EDITION OF ASCE 7
AND TESTED FOR CAPACITY IN ACCORDANCE WITH THE TEST METHODS IN THE APPLICABLE EDITION OF ANSI/SPRI ES-1.
3. THE ATTACHMENT CAPACITY OF THE INSULATED METAL PANELS SHOULD BE VERIFIED.
4. FOR STEEL ROOF DECKS: FILL STEEL DECK FLUTES WITH SPRAY FOAM INSULATION PRIOR TO THE INSTALLATION OF ABOVE DECK
INSULATION A MINIMUM OF 12 INCHES (305 mm) FROM FACE OF WALL.
®
EVERGUARD
®
WATER-BLOCKISSUE / REVISION DATEDRAWING #
GAF ●
1 Campus Drive Parsippany, NJ 07054 ● www.gaf.com ● [email protected] ● 800-766-3411
LEGEND
SCALE
N.T.S.
THIS DETAIL APPLIES TO:
ColdStorage
3/1/21
SINGLE-PLY: TPO & PVC 60-80 mil membranes
202E
METAL GRAVEL STOP WITH HEMMED EDGE AT INSULATED
METAL PANEL
ADHERED SYSTEMS
MECHANICALLY ATTACHED SYSTEMS
RHINOBOND SYSTEMS
METAL PANEL CAP
(BY OTHERS)
INSULATED METAL PANEL
CONTINUOUS BEAD OF
FLEXSEAL
TM
CAULK GRADE
SEALANT
EVERGUARD
®
WATER BLOCK
THERMAL CUT IN PANEL SKIN
WOOD NAILER MIN 2" X _"
METAL GRAVEL STOP WITH
HEMMED EDGE, SEE NOTE 2
GALVANIZED ANGULAR RING
SHANK NAIL @ 4" (102 mm) O.C.
STAGGERED OR DRILL-TEC
™
FASTENERS 12" (305 mm) O.C.
EVERGUARD
®
TPO COVER TAPE
REINFORCED EVERGUARD
®
MEMBRANE
FOAM FILLED POCKET MIN. 1"
(25.4 mm) OR AS SPECIFIED
ROOF DECK/SUBSTRATE
MULTIPLE LAYERS OF
ENERGYGUARD
™
ROOF INSULATION,
STAGGERED AND OFFSET
CONTINUOUS BEAD OF
FLEXSEAL
TM
CAULK GRADE
SEALANT.
®
EVERGUARD
®
WATER-BLOCKISSUE / REVISION DATEDRAWING #
GAF ●
1 Campus Drive Parsippany, NJ 07054 ● www.gaf.com ● [email protected] ● 800-766-3411
LEGEND
SCALE
N.T.S.
THIS DETAIL APPLIES TO:
ColdStorage
3/1/21
SINGLE-PLY: TPO & PVC 60-80 mil membranes
202C
METAL GRAVEL STOP WITH HEMMED EDGE
ADHERED SYSTEMS
MECHANICALLY ATTACHED SYSTEMS
RHINOBOND SYSTEMS
NOTE:
1. CLEAN METAL AND MEMBRANE WITH EVERGUARD
Ò TPO SEAM CLEANER AND ALLOW TO DRY. ONCE DRY, PRIME METAL AND
MEMBRANE WITH EVERGUARD
Ò TPO PRIMER BEFORE INSTALLING EVERGUARD
Ò TPO COVER TAPE.
2. METAL GRAVEL STOP SHOULD BE DESIGNED FOR WIND RESISTANCE IN ACCORDANCE WITH THE APPLICABLE EDITION OF
ASCE 7 AND TESTED FOR CAPACITY IN ACCORDANCE WITH THE TEST METHODS IN THE APPLICABLE EDITION OF ANSI/SPRI ES-1.
3. FOR STEEL ROOF DECKS: FILL STEEL DECK FLUTES WITH SPRAY FOAM INSULATION PRIOR TO THE INSTALLATION OF ABOVE
DECK INSULATION A MINIMUM OF 12 INCHES (305 mm) FROM FACE OF WALL.
EVERGUARD
®
WATER BLOCK
REINFORCED EVERGUARD
®
MEMBRANE
INSULATED METAL PANEL
FOAM FILLED POCKET MIN. 1"
(25.4 mm) OR AS SPECIFIED
ROOF DECK/SUBSTRATE
METAL EDGE, SEE NOTE 2
MULTIPLE LAYERS OF
ENERGYGUARD
™
ROOF INSULATION,
STAGGERED AND OFFSET
EVERGUARD
®
TPO COVER
TAPE
CONTINUOUS BEAD OF
FLEXSEAL
TM
CAULK GRADE
SEALANT
®
EVERGUARD
®
WATER-BLOCK
ISSUE / REVISION DATEDRAWING #
GAF ●
1 Campus Drive Parsippany, NJ 07054 ● www.gaf.com ● [email protected] ● 800-766-3411
LEGEND
SCALE
N.T.S.
THIS DETAIL APPLIES TO:
ColdStorage
3/1/21
SINGLE-PLY: TPO & PVC 60-80 mil membranes
203D
METAL ROOF EDGE WITH COVER TAPE DETAIL AT
INSULATED METAL PANELS
ADHERED SYSTEMS
MECHANICALLY ATTACHED SYSTEMS
RHINOBOND SYSTEMS
METAL PANEL CAP
(BY OTHERS)
NOTE:
1. CLEAN METAL AND MEMBRANE WITH EVERGUARD
Ò TPO SEAM CLEANER AND ALLOW TO DRY. ONCE DRY, PRIME METAL AND
MEMBRANE WITH EVERGUARD
Ò TPO PRIMER BEFORE INSTALLING EVERGUARD
Ò TPO COVER TAPE.
2. PERIMETER EDGE METAL SHOULD BE DESIGNED FOR WIND RESISTANCE IN ACCORDANCE WITH THE APPLICABLE EDITION OF
ASCE 7 AND TESTED FOR CAPACITY IN ACCORDANCE WITH THE TEST METHODS IN THE APPLICABLE EDITION OF ANSI/SPRI ES-1.
3. THE ATTACHMENT CAPACITY OF THE INSULATED METAL PANELS SHOULD BE VERIFIED.
4. FOR STEEL ROOF DECKS: FILL STEEL DECK FLUTES WITH SPRAY FOAM INSULATION PRIOR TO THE INSTALLATION OF ABOVE
DECK INSULATION A MINIMUM OF 12 INCHES (305 mm) FROM FACE OF WALL.
EVERGUARD
®
WATER BLOCK
THERMAL CUT IN PANEL SKIN
WOOD NAILER MIN 2" X _"
WALL
SNAP-ON FASCIA,
SEE NOTE 1
REINFORCED EVERGUARD
®
MEMBRANE
FOAM FILLED POCKET MIN. 1"
(25.4 mm) OR AS SPECIFIED
ROOF DECK/SUBSTRATE
MULTIPLE LAYERS OF
ENERGYGUARD
™
ROOF INSULATION,
STAGGERED AND OFFSET
®
FLEXSEAL
TM
CAULK-GRADE SEALANT
EVERGUARD
®
WATER-BLOCK
ISSUE / REVISION DATEDRAWING #
GAF ●
1 Campus Drive Parsippany, NJ 07054 ● www.gaf.com ● [email protected] ● 800-766-3411
LEGEND
SCALE
N.T.S.
THIS DETAIL APPLIES TO:
ColdStorage
3/1/21
SINGLE-PLY: TPO & PVC 60-80 mil membranes
205
SNAP ON FASCIA DETAIL
ADHERED SYSTEMS
MECHANICALLY ATTACHED SYSTEMS
RHINOBOND SYSTEMS
1. SNAP-ON FASCIA SHOULD BE DESIGNED FOR WIND RESISTANCE IN ACCORDANCE WITH THE APPLICABLE EDITION OF ASCE 7
AND TESTED FOR CAPACITY IN ACCORDANCE WITH THE TEST METHODS IN THE APPLICABLE EDITION OF ANSI/SPRI ES-1.
2. FOR STEEL ROOF DECKS: FILL STEEL DECK FLUTES WITH SPRAY FOAM INSULATION PRIOR TO THE INSTALLATION OF ABOVE
DECK INSULATION A MINIMUM OF 12 INCHES (305 mm) FROM FACE OF WALL.
NOTE:
SHEET METAL GUTTER
WOOD NAILER MIN 2" X _"
WALL
REINFORCED EVERGUARD
®
MEMBRANE
FOAM FILLED POCKET MIN. 1"
(25.4 mm) OR AS SPECIFIED
ROOF DECK/SUBSTRATE
EVERGUARD
®
TPO UTILITY FLASHING
MEMBRANE (TPO ONLY) OR MIN. 8"
(203 mm) WIDE REINFORCED
EVERGUARD
®
MEMBRANE
HEAT WELD BOTH SIDES
EVERGUARD
®
COATED
METAL EDGE, SEE NOTE 1
MULTIPLE LAYERS OF
ENERGYGUARD
™
ROOF INSULATION,
STAGGERED AND OFFSET
®
HEAT-WELDED
FLEXSEAL
TM
CAULK-GRADE SEALANT
ISSUE / REVISION DATEDRAWING #
GAF ●
1 Campus Drive Parsippany, NJ 07054 ● www.gaf.com ● [email protected] ● 800-766-3411
LEGEND
SCALE
N.T.S.
THIS DETAIL APPLIES TO:
ColdStorage
3/1/21
SINGLE-PLY: TPO & PVC 60-80 mil membranes
211B
GUTTER WITH COATED METAL ROOF EDGE
ADHERED SYSTEMS
MECHANICALLY ATTACHED SYSTEMS
RHINOBOND SYSTEMS
1. METAL EDGE SHOULD BE DESIGNED FOR WIND RESISTANCE IN ACCORDANCE WITH THE APPLICABLE EDITION OF ASCE 7
AND TESTED FOR CAPACITY IN ACCORDANCE WITH THE TEST METHODS IN THE APPLICABLE EDITION OF ANSI/SPRI ES-1.
2. FOR STEEL ROOF DECKS: FILL STEEL DECK FLUTES WITH SPRAY FOAM INSULATION PRIOR TO THE INSTALLATION OF
ABOVE DECK INSULATION A MINIMUM OF 12 INCHES (305 mm) FROM FACE OF WALL.
NOTE:
EVERGUARD
®
WATER BLOCK
SHEET METAL GUTTER
WOOD NAILER MIN 2" X _"
WALL
REINFORCED EVERGUARD
®
MEMBRANE
FOAM FILLED POCKET MIN. 1"
(25.4 mm) OR AS SPECIFIED
ROOF DECK/SUBSTRATE
METAL EDGE, SEE NOTE 2
MULTIPLE LAYERS OF
ENERGYGUARD
™
ROOF INSULATION,
STAGGERED AND OFFSET
CONTINUOUS BEAD OF
FLEXSEAL
TM
CAULK GRADE
SEALANT OR EVERGUARD
®
CUT EDGE SEALANT.
EVERGUARD
®
TPO COVER
TAPE
®
FLEXSEAL
TM
CAULK-GRADE SEALANTISSUE / REVISION DATEDRAWING #
GAF ●
1 Campus Drive Parsippany, NJ 07054 ● www.gaf.com ● [email protected] ● 800-766-3411
LEGEND
SCALE
N.T.S.
THIS DETAIL APPLIES TO:
ColdStorage
3/1/21
SINGLE-PLY: TPO & PVC 60-80 mil membranes
211C
GUTTER WITH METAL ROOF EDGE AND COVER TAPE
ADHERED SYSTEMS
MECHANICALLY ATTACHED SYSTEMS
RHINOBOND SYSTEMS
EVERGUARD
®
WATER BLOCK
NOTE:
1. CLEAN METAL AND MEMBRANE WITH EVERGUARD
Ò TPO SEAM CLEANER AND ALLOW TO DRY. ONCE DRY, PRIME METAL AND
MEMBRANE WITH EVERGUARD
Ò TPO PRIMER BEFORE INSTALLING EVERGUARD
Ò TPO COVER TAPE.
2. PERIMETER EDGE METAL SHOULD BE DESIGNED FOR WIND RESISTANCE IN ACCORDANCE WITH THE APPLICABLE EDITION OF
ASCE 7 AND TESTED FOR CAPACITY IN ACCORDANCE WITH THE TEST METHODS IN THE APPLICABLE EDITION OF ANSI/SPRI ES-1.
3. FOR STEEL ROOF DECKS: FILL STEEL DECK FLUTES WITH SPRAY FOAM INSULATION PRIOR TO THE INSTALLATION OF ABOVE
DECK INSULATION A MINIMUM OF 12 INCHES (305 mm) FROM FACE OF WALL.
WOOD NAILER MIN 2" X _"
WALL
EVERGUARD
®
EZ FASCIA WITH
CONCEALED JOINT
SPLICE, SEE NOTE 1
REINFORCED EVERGUARD
®
MEMBRANE
FOAM FILLED POCKET MIN. 1"
(25.4 mm) OR AS SPECIFIED
ROOF DECK/SUBSTRATE
MULTIPLE LAYERS OF
ENERGYGUARD
™
ROOF INSULATION,
STAGGERED AND OFFSET
®
FLEXSEAL
TM
CAULK-GRADE SEALANT
EVERGUARD
®
WATER-BLOCK
ISSUE / REVISION DATEDRAWING #
GAF ●
1 Campus Drive Parsippany, NJ 07054 ● www.gaf.com ● [email protected] ● 800-766-3411
LEGEND
SCALE
N.T.S.
THIS DETAIL APPLIES TO:
ColdStorage
4/1/21
SINGLE-PLY: TPO & PVC 60-80 mil membranes
232E
EZ FASCIA DETAIL
ADHERED SYSTEMS
MECHANICALLY ATTACHED SYSTEMS
RHINOBOND SYSTEMS
1. EZ FASCIA SHOULD BE DESIGNED FOR WIND RESISTANCE IN ACCORDANCE WITH THE APPLICABLE EDITION OF ASCE 7 AND
TESTED FOR CAPACITY IN ACCORDANCE WITH THE TEST METHODS IN ANSI/SPRI ES-1.
2. FOR STEEL ROOF DECKS: FILL STEEL DECK FLUTES WITH SPRAY FOAM INSULATION PRIOR TO THE INSTALLATION OF ABOVE
DECK INSULATION A MINIMUM OF 12 INCHES (305 mm) FROM FACE OF WALL.
NOTE:
EVERGUARD
®
WATER BLOCK
®
NOTE:
1. EXPOSED WALLS/CURBS MUST BE WATERPROOFED AND MAINTAINED ABOVE THE BASE FLASHING IN ORDER FOR ANY
SURFACE-MOUNTED TERMINATION TO BE EFFECTIVE.
2. FOR STEEL ROOF DECKS: FILL STEEL DECK FLUTES WITH SPRAY FOAM INSULATION PRIOR TO THE INSTALLATION OF
ABOVE DECK INSULATION A MINIMUM OF 12 INCHES (305 mm) FROM FACE OF WALL.
HEAT-WELDED
EVERGUARD
®
BONDING ADHESIVE
-OPTIONAL UP TO 30" (762 mm) FLASHING HEIGHT
ISSUE / REVISION DATEDRAWING #
GAF ●
1 Campus Drive Parsippany, NJ 07054 ● www.gaf.com ● [email protected] ● 800-766-3411
LEGEND
SCALE
N.T.S.
THIS DETAIL APPLIES TO:
ColdStorage
3/1/21
SINGLE-PLY: TPO & PVC 60-80 mil membranes
301B
WALL FLASHING WITH COUNTERFLASHING
ADHERED SYSTEMS
MECHANICALLY ATTACHED SYSTEMS
RHINOBOND SYSTEMS
FOAM FILLED POCKET MIN 1" (25.4 mm) OR AS SPECIFIED
MULTIPLE LAYERS OF ENERGYGUARD
™
ROOF
INSULATION, STAGGERED AND OFFSET
ROOF DECK/SUBSTRATE
REINFORCED EVERGUARD
®
MEMBRANE
DRILL-TEC
™
TERMINATION BAR FASTENED 12" O.C.
EVERGUARD
®
WATER BLOCK
METAL SURFACE MOUNTED COUNTERFLASHING
DRILL-TEC
™
FASTENERS AND SEALING
WASHERS FASTENED 12" (305 mm) O.C.
FLEXSEAL
™
CAULK GRADE SEALANT
®
NOTE:
1. EXPOSED WALLS/CURBS MUST BE WATERPROOFED AND MAINTAINED ABOVE THE BASE FLASHING IN ORDER FOR ANY
SURFACE-MOUNTED TERMINATION TO BE EFFECTIVE.
2. FOR STEEL ROOF DECKS: FILL STEEL DECK FLUTES WITH SPRAY FOAM INSULATION PRIOR TO THE INSTALLATION OF
ABOVE DECK INSULATION A MINIMUM OF 12 INCHES (305 mm) FROM FACE OF WALL.
HEAT-WELDED
EVERGUARD
®
BONDING ADHESIVE
ISSUE / REVISION DATEDRAWING #
GAF ●
1 Campus Drive Parsippany, NJ 07054 ● www.gaf.com ● [email protected] ● 800-766-3411
LEGEND
SCALE
N.T.S.
THIS DETAIL APPLIES TO:
ColdStorage
3/17/21
SINGLE-PLY: TPO & PVC 60-80 mil membranes
302B
WALL/CURB FLASHING WITH TERMINATION BAR DETAIL
ADHERED SYSTEMS
MECHANICALLY ATTACHED SYSTEMS
RHINOBOND SYSTEMS
HEAT WELD LAP
FOAM FILLED POCKET MIN 1" (25.4 mm)
OR AS SPECIFIED
ROOF DECK/SUBSTRATE
MULTIPLE LAYERS OF ENERGYGUARD
™
ROOF
INSULATION, STAGGERED AND OFFSET
REINFORCED EVERGUARD
®
MEMBRANE
EVERGUARD
®
BONDING ADHESIVE - OPTIONAL
UP TO 30" (762 mm) FLASHING HEIGHT
DRILL-TEC
™
TERMINATION BAR FASTENED
12" (305 mm) O.C.
EVERGUARD
®
WATER BLOCK
DRILL-TEC
™
TERMINATION BAR WITH
DRILL-TEC
™
FASTENERS AND SEALING
WASHERS FASTENED 12" (305 mm) O.C.
FLEXSEAL
™
CAULK GRADE SEALANT
EVERGUARD
®
WATER BLOCK OR
FLEXSEAL
™
CAULK GRADE SEALANT
EVERGUARD
®
WATER-BLOCK
®
NOTE:
1. METAL COPING CAP SHOULD BE DESIGNED FOR WIND RESISTANCE IN ACCORDANCE WITH THE APPLICABLE EDITION OF ASCE 7
AND TESTED FOR CAPACITY IN ACCORDANCE WITH THE TEST METHODS IN THE APPLICABLE EDITION OF ANSI/SPRI ES-1.
2. THE ATTACHMENT CAPACITY OF THE INSULATED METAL PANELS SHOULD BE VERIFIED.
3. FOR STEEL ROOF DECKS: FILL STEEL DECK FLUTES WITH SPRAY FOAM INSULATION PRIOR TO THE INSTALLATION OF ABOVE
DECK INSULATION A MINIMUM OF 12 INCHES (305 mm) FROM FACE OF WALL
FOAM FILLED POCKET
MIN 1" (25.4 mm) OR AS
SPECIFIED
MULTIPLE LAYERS OF ENERGYGUARD
™
ROOF
INSULATION, STAGGERED AND OFFSET
ROOF DECK/SUBSTRATE
REINFORCED EVERGUARD
®
MEMBRANE
METAL PANEL CAP (BY OTHERS)
ISSUE / REVISION DATEDRAWING #
GAF ●
1 Campus Drive Parsippany, NJ 07054 ● www.gaf.com ● [email protected] ● 800-766-3411
LEGEND
SCALE
N.T.S.
THIS DETAIL APPLIES TO:
ColdStorage
3/1/21
SINGLE-PLY: TPO & PVC 60-80 mil membranes
303B
INSULATED METAL PANEL WALL WITH COPING CAP
ADHERED SYSTEMS
MECHANICALLY ATTACHED SYSTEMS
RHINOBOND SYSTEMS
METAL COPING CAP, SEE NOTE 1
INSULATED METAL PANEL
HEAT-WELDED
EVERGUARD
®
WATER-BLOCK
EVERGUARD
®
BONDING ADHESIVE
EVERGUARD
®
WATER BLOCK
EVERGUARD
®
WATER BLOCK
EVERGUARD
®
WATER BLOCK
HEAT-WELDED LAP
EVERGUARD
®
BONDING ADHESIVE
THERMAL CUT IN
PANEL SKIN
INSULATED METAL
PANEL
®
NOTE:
1. METAL COPING CAP SHOULD BE DESIGNED FOR WIND RESISTANCE IN ACCORDANCE WITH THE APPLICABLE EDITION OF ASCE 7 AND
TESTED FOR CAPACITY IN ACCORDANCE WITH THE TEST METHODS IN ANSI/SPRI ES-1.
2. A VAPOR RETARDER AT THE DECK LEVEL MAY BE USED IF THERE ARE CONCERNS WITH POTENTIAL MOISTURE ISSUES DUE TO CERTAIN
CONSTRUCTION PROCESSES OR OTHER SOURCES DURING BUILDING USE.
3. REFER TO GAF SA PRIMER INSTALLATION INSTRUCTIONS FOR GENERAL GUIDELINES.
4. A MINIMUM
1
2
INCH THICK GLASS-MAT-FACED OR FIBER-REINFORCED GYPSUM BOARD IS REQUIRED OVER STEEL DECKS.
5. MAINTAIN SEPARATION BETWEEN VAPOR RETARDER AND MEMBRANE/ ADHESIVE TO AVOID POTENTIAL INCOMPATIBILITY ISSUES.
6. FOR STEEL ROOF DECKS: FILL STEEL DECK FLUTES WITH SPRAY FOAM INSULATION PRIOR TO THE INSTALLATION OF ABOVE DECK
INSULATION A MINIMUM OF 12 INCHES (305 mm) FROM FACE OF WALL, BOTH SIDES OF WALL.
7. AIR SEAL WALL-TO-ROOF DECK INTERFACE.
MULTIPLE LAYERS OF ENERGYGUARD
™
ROOF
INSULATION, STAGGERED AND OFFSET
GAF SA VAPOR RETARDER, SEE NOTE 2.
EXTEND 2" MINIMUM (51 mm) UP WALL FACE
REINFORCED EVERGUARD
®
MEMBRANE
ISSUE / REVISION DATEDRAWING #
GAF ●
1 Campus Drive Parsippany, NJ 07054 ● www.gaf.com ● [email protected] ● 800-766-3411
LEGEND
SCALE
N.T.S.
THIS DETAIL APPLIES TO:
ColdStorage
4/6/21
SINGLE-PLY: TPO & PVC 60-80 mil membranes
303C
INSULATED METAL PANEL WALL WITH COPING CAP AND
SA VAPOR RETARDER
ADHERED SYSTEMS
MECHANICALLY ATTACHED SYSTEMS
RHINOBOND SYSTEMS
METAL COPING CAP, SEE NOTE 1
HEAT-WELDED
EVERGUARD
®
WATER-BLOCK
EVERGUARD
®
BONDING ADHESIVE
EVERGUARD
®
WATER BLOCK
EVERGUARD
®
WATER BLOCK
EVERGUARD
®
WATER BLOCK
HEAT-WELDED LAP
EVERGUARD
®
BONDING ADHESIVE
ROOF DECK/SUBSTRATE
WALL
GAF SA PRIMER
®
NOTE:
1. COATED METAL EDGE SHOULD BE DESIGNED FOR WIND RESISTANCE IN ACCORDANCE WITH THE APPLICABLE EDITION OF
ASCE 7 AND TESTED FOR CAPACITY IN ACCORDANCE WITH THE TEST METHODS IN ANSI/SPRI ES-1.
2. STEEL ROOF DECKS: FILL STEEL DECK FLUTES WITH SPRAY FOAM INSULATION PRIOR TO THE INSTALLATION OF ABOVE DECK
INSULATION A MINIMUM OF 12 INCHES (305 mm) FROM FACE OF WALL.
ISSUE / REVISION DATEDRAWING #
GAF ●
1 Campus Drive Parsippany, NJ 07054 ● www.gaf.com ● [email protected] ● 800-766-3411
LEGEND
SCALE
N.T.S.
THIS DETAIL APPLIES TO:
ColdStorage
3/22/21
SINGLE-PLY: TPO & PVC 60-80 mil membranes
304B
WALL FLASHING WITH COATED METAL EDGE DETAIL
ADHERED SYSTEMS
MECHANICALLY ATTACHED SYSTEMS
RHINOBOND SYSTEMS
HEAT-WELDED
EVERGUARD
®
BONDING ADHESIVE
MULTIPLE LAYERS OF ENERGYGUARD
™
ROOF INSULATION
ROOF DECK/SUBSTRATE
FOAM FILLED POCKET MIN 1"
(25.4 mm) OR AS SPECIFIED
REINFORCED EVERGUARD
®
MEMBRANE
EVERGUARD
®
COATED METAL,
SEE NOTE 1
EVERGUARD
®
TPO UTILITY FLASHING
MEMBRANE OR 6" (152 mm) REINFORCED
EVERGUARD
®
MEMBRANE
WALL
ANGULAR ROOFING NAILS
12" (305 mm) O.C.
REINFORCED EVERGUARD
®
MEMBRANE
WOOD NAILER MIN 2" X _"
WALL
FOAM FILLED POCKET MIN. 1"
(25.4 mm) OR AS SPECIFIED
ROOF DECK/SUBSTRATE
METAL EDGE, SEE NOTE 2
MULTIPLE LAYERS OF
ENERGYGUARD
™
ROOF INSULATION,
STAGGERED AND OFFSET
EVERGUARD
®
TPO COVER TAPE
CONTINUOUS BEAD OF
FLEXSEAL
TM
CAULK GRADE
SEALANT.
®
NOTE:
1. CLEAN METAL AND MEMBRANE WITH EVERGUARD
Ò TPO SEAM CLEANER AND ALLOW TO DRY. ONCE DRY, PRIME METAL AND
MEMBRANE WITH EVERGUARD
Ò TPO PRIMER BEFORE INSTALLING EVERGUARD
Ò TPO COVER TAPE.
2. METAL EDGE SHOULD BE DESIGNED FOR WIND RESISTANCE IN ACCORDANCE WITH THE APPLICABLE EDITION OF ASCE 7 AND
TESTED FOR CAPACITY IN ACCORDANCE WITH THE TEST METHODS IN ANSI/SPRI ES-1.
3. FOR STEEL ROOF DECKS: FILL STEEL DECK FLUTES WITH SPRAY FOAM INSULATION PRIOR TO THE INSTALLATION OF ABOVE
DECK INSULATION A MINIMUM OF 12 INCHES (305 mm) FROM FACE OF WALL.
ISSUE / REVISION DATEDRAWING #
GAF ●
1 Campus Drive Parsippany, NJ 07054 ● www.gaf.com ● [email protected] ● 800-766-3411
LEGEND
SCALE
N.T.S.
THIS DETAIL APPLIES TO:
ColdStorage
3/22/21
SINGLE-PLY: TPO 60-80 mil membranes
304C
WALL FLASHING WITH METAL EDGE WITH COVER TAPE
DETAIL
ADHERED SYSTEMS
MECHANICALLY ATTACHED SYSTEMS
RHINOBOND SYSTEMS
EVERGUARD
®
WATER BLOCK
EVERGUARD
®
WATER BLOCK
HEAT-WELDED
EVERGUARD
®
BONDING ADHESIVE
®
ISSUE / REVISION DATEDRAWING #
GAF ●
1 Campus Drive Parsippany, NJ 07054 ● www.gaf.com ● [email protected] ● 800-766-3411
LEGEND
SCALE
N.T.S.
THIS DETAIL APPLIES TO:
ColdStorage
4/6/21
SINGLE-PLY: TPO & PVC 60-80 mil membranes
309
BASE WALL TERMINATION WITH SA VAPOR RETARDER
DETAIL AT WALL
ADHERED SYSTEMS
MECHANICALLY ATTACHED SYSTEMS
RHINOBOND SYSTEMS
HEAT-WELDED
EVERGUARD
®
WATER-BLOCK
EVERGUARD
®
BONDING ADHESIVE
GAF SA PRIMER
1.USE DETAIL IN CONJUNCTION WITH THE STANDARD TERMINATION DETAIL FOR APPROVED ROOF SYSTEM.
2. A VAPOR RETARDER AT THE DECK LEVEL MAY BE USED IF THERE ARE CONCERNS WITH POTENTIAL MOISTURE
ISSUES DUE TO CERTAIN CONSTRUCTION PROCESSES OR OTHER SOURCES DURING BUILDING USE.
3. REFER TO GAF SA PRIMER INSTALLATION INSTRUCTIONS FOR GENERAL GUIDELINES.
4. MAINTAIN SEPARATION BETWEEN VAPOR RETARDER AND MEMBRANE/ ADHESIVE TO AVOID POTENTIAL
INCOMPATIBILITY ISSUES.
5. FOR STEEL ROOF DECKS: FILL STEEL DECK FLUTES WITH SPRAY FOAM INSULATION PRIOR TO THE INSTALLATION
OF ABOVE DECK INSULATION A MINIMUM OF 12 INCHES (305 mm) FROM FACE OF WALL.
6. AIR SEAL WALL-TO-ROOF DECK INTERFACE.
NOTE:
FOAM FILLED POCKET MIN. 1"
(25.4 mm) OR AS SPECIFIED
ROOF DECK/SUBSTRATE
MULTIPLE LAYERS OF
ENERGYGUARD
™
ROOF
INSULATION, STAGGERED
AND OFFSET
MINIMUM 1/2 INCH (12.7 mm)
THICK GLASS-MAT-FACED
OR FIBER-REINFORCED
GYPSUM BOARD
WALL
GAF SA VAPOR RETARDER, SEE
NOTE 2. EXTEND 2" MINIMUM
(51 mm) UP WALL FACE
REINFORCED EVERGUARD
®
MEMBRANE
STEEL DECK
REFERENCE EVERGUARD
®
300 SERIES PARAPET WALL
AND CURB DETAILS FOR
TERMINATION
FOAM FILLED POCKET MIN. 1"
(25.4 mm) OR AS SPECIFIED
MULTIPLE LAYERS OF
ENERGYGUARD
™
ROOF
INSULATION, STAGGERED
AND OFFSET
REINFORCED EVERGUARD
®
MEMBRANE
FOAM FILLED GAP AT
PENETRATION OPENING
WHEN NEEDED TO
SUPPORT VAPOR
RETARDER
EVERGUARD
®
TPO UTILITY FLASHING MEMBRANE (TPO ONLY)
OR REINFORCED EVERGUARD
®
MEMBRANE
EVERGUARD
®
BONDING ADHESIVE
REINFORCED EVERGUARD
®
MEMBRANE
ROOF DECK/SUBSTRATE
FOAM FILLED POCKET MIN 1" (25.4 mm) OR AS SPECIFIED
DRILL-TEC™
PLATES &
FASTENERS 12"
(305 mm) O.C.
MULTIPLE LAYERS OF
ENERGYGUARD
™
ROOF
INSULATION, STAGGERED
AND OFFSET
EVERGUARD
®
COATED METAL
®
NOTE:
1. STEEL ROOF DECKS: FILL STEEL DECK FLUTES WITH SPRAY FOAM INSULATION PRIOR TO THE INSTALLATION OF ABOVE
DECK INSULATION A MINIMUM OF 12 INCHES (305 mm) FROM FACE OF WALL.
REINFORCED EVERGUARD
®
MEMBRANE
ISSUE / REVISION DATEDRAWING #
GAF ●
1 Campus Drive Parsippany, NJ 07054 ● www.gaf.com ● [email protected] ● 800-766-3411
LEGEND
SCALE
N.T.S.
THIS DETAIL APPLIES TO:
ColdStorage
3/15/21
SINGLE-PLY: TPO & PVC 60-80 mil membranes
323B
SCUPPER - FIELD FABRICATED WITH COATED METAL -
OVERFLOW
ADHERED SYSTEMS
MECHANICALLY ATTACHED SYSTEMS
RHINOBOND SYSTEMS
REFERENCE EVERGUARD
®
PARAPET WALL & CURB FLASHING
DETAILS (300 SERIES) FOR WALL OR CURB TERMINATION
HEAT WELD ON BOTH ENDS
HEAT-WELDED LAP
HEAT-WELDED
LAP
EVERGUARD
®
TPO UTILITY FLASHING MEMBRANE (TPO ONLY)
OR REINFORCED EVERGUARD
®
MEMBRANE
EVERGUARD
®
WATER-BLOCK
REINFORCED EVERGUARD
®
MEMBRANE
FLEXSEAL
TM
CAULK GRADE SEALANT
EVERGUARD
®
COATED METAL
HEAT-WELDED
EVERGUARD
®
WATER-BLOCK
EVERGUARD
®
BONDING ADHESIVE
EVERGUARD
®
BONDING ADHESIVE
HEAT-WELDED LAP
EVERGUARD
®
TPO UTILITY FLASHING
MEMBRANE (TPO ONLY) OR MIN. 8" (203 mm)
WIDE REINFORCED EVERGUARD
®
MEMBRANE
COPING CAP, SEE NOTE 1
EVERGUARD
®
BONDING ADHESIVE
REINFORCED EVERGUARD
®
MEMBRANE
EVERGUARD
®
WATER BLOCK
ROOF DECK/SUBSTRATE
FOAM FILLED POCKET MIN 1" (25.4 mm)
OR AS SPECIFIED
DRILL-TEC™ PLATES & FASTENERS
12" (305 mm) O.C.
MULTIPLE LAYERS OF ENERGYGUARD
™
ROOF
INSULATION, STAGGERED AND OFFSET
SHEET METAL
CONDUCTOR
HEAD
EVERGUARD
®
COATED METAL
®
NOTE:
1. METAL EDGE SHOULD BE DESIGNED FOR WIND RESISTANCE IN ACCORDANCE WITH THE APPLICABLE EDITION OF ASCE 7
AND TESTED FOR CAPACITY IN ACCORDANCE WITH THE TEST METHODS IN THE APPLICABLE EDITION OF ANSI/SPRI ES-1. FOR
2. STEEL ROOF DECKS: FILL STEEL DECK FLUTES WITH SPRAY FOAM INSULATION PRIOR TO THE INSTALLATION OF ABOVE
DECK INSULATION A MINIMUM OF 12 INCHES (305 mm) FROM FACE OF WALL.
HEAT-WELDED
FLEXSEAL
™
CAULK GRADE SEALANT
REINFORCED EVERGUARD
®
MEMBRANE
ISSUE / REVISION DATEDRAWING #
GAF ●
1 Campus Drive Parsippany, NJ 07054 ● www.gaf.com ● [email protected] ● 800-766-3411
LEGEND
SCALE
N.T.S.
THIS DETAIL APPLIES TO:
ColdStorage
3/1/21
SINGLE-PLY: TPO & PVC 60-80 mil membranes
324B
THROUGH WALL SCUPPER WITH COATED METAL
ADHERED SYSTEMS
MECHANICALLY ATTACHED SYSTEMS
RHINOBOND SYSTEMS
CONTINUOUS BEAD OF FLEXSEAL
TM
CAULK
GRADE SEALANT.
ROOF DECK/SUBSTRATE
FOAM FILLED POCKET MIN 1"
(25.4 mm) OR AS SPECIFIED
MULTIPLE LAYERS OF
ENERGYGUARD
™
ROOF INSULATION,
STAGGERED AND OFFSET
®
NOTE:
1. SCUPPER MUST ALSO BE SEALED ON OUTSIDE WALL.
2. FOR ALTERNATE BASE ATTACHMENT, REFER TO DETAIL 307.
3. STEEL ROOF DECKS: FILL STEEL DECK FLUTES WITH SPRAY FOAM INSULATION PRIOR TO THE INSTALLATION OF ABOVE
DECK INSULATION A MINIMUM OF 12 INCHES (305 mm) FROM FACE OF WALL.
HEAT-WELDED
ISSUE / REVISION DATEDRAWING #
GAF ●
1 Campus Drive Parsippany, NJ 07054 ● www.gaf.com ● [email protected] ● 800-766-3411
LEGEND
SCALE
N.T.S.
THIS DETAIL APPLIES TO:
ColdStorage
3/15/21
SINGLE-PLY: TPO & PVC 60-80 mil membranes
324D
THROUGH WALL SCUPPER - PREFABRICATED DETAIL
ADHERED SYSTEMS
MECHANICALLY ATTACHED SYSTEMS
RHINOBOND SYSTEMS
REINFORCED EVERGUARD
®
MEMBRANE
REAR VIEW OF SCUPPER
REINFORCED EVERGUARD
®
MEMBRANE
SECURE WITH DRILL-TEC
™
FASTENERS
PREMANUFACTURED EVERGUARD
®
TPO SCUPPER FASTENED WITH 4
FASTENERS OR 12" (305 mm) O.C.
®
ISSUE / REVISION DATEDRAWING #
GAF ●
1 Campus Drive Parsippany, NJ 07054 ● www.gaf.com ● [email protected] ● 800-766-3411
LEGEND
SCALE
N.T.S.
THIS DETAIL APPLIES TO:
ColdStorage
3/22/21
SINGLE-PLY: TPO & PVC 60-80 mil membranes
350
AIR SEAL DETAIL AT STEEL DECK TO WALL INTERFACE
ADHERED SYSTEMS
MECHANICALLY ATTACHED SYSTEMS
RHINOBOND SYSTEMS
STEEL DECK PARALLEL TO WALL
STEEL DECK PERPENDICULAR TO WALL
FILL FIRST TWO STEEL DECK FLUTES WITH SPRAY FOAM
INSULATION PRIOR TO THE INSTALLATION OF ABOVE DECK INSULATION
FILL STEEL DECK FLUTES WITH SPRAY FOAM INSULATION PRIOR TO THE INSTALLATION
OF ABOVE DECK INSULATION A MINIMUM OF 12 INCHES (305 mm) FROM FACE OF WALL
STEEL DECK
FOAM FILLED POCKET MIN. 1"
(25.4 mm) OR AS SPECIFIED
MULTIPLE LAYERS OF
ENERGYGUARD
™
ROOF INSULATION,
STAGGERED AND OFFSET
STEEL DECK
STEEL DECK
WALL
STEEL DECK
FOAM FILLED POCKET MIN. 1"
(25.4 mm) OR AS SPECIFIED
MULTIPLE LAYERS OF
ENERGYGUARD
™
ROOF INSULATION,
STAGGERED AND OFFSET
WALL
SHEET METAL CLOSURE
SHEET METAL CLOSURE
®
NOTE:
1. SEE EVERGUARD
®
DETAIL 330 FOR LAP APPLICATION.
2. FOR STEEL ROOF DECKS: FILL STEEL DECK FLUTES WITH SPRAY FOAM INSULATION PRIOR TO THE INSTALLATION OF
ABOVE DECK INSULATION A MINIMUM OF 12 INCHES (305 mm) FROM EDGE OF EXPANSION JOINT.
HEAT-WELDED
TACK WELD INTERMITTENTLY ON BOTH
CURBS TO HOLD IN PLACE IF NEEDED
FACTORY-FABRICATED
TPO EVERGUARD
®
EXPANSION JOINT COVER
COMPRESSIBLE
ROD/BATT INSULATION
FIELD MEMBRANE SHOULD RUN
INTO THE EXPANSION JOINT
CONTINUING ONTO THE OTHER SIDE
AND TERMINATING AS INDICATED
WOOD NAILER, 5/4"
(31.8 mm) x 4" (102 mm)
MIN. SECURED TO DECK
FOAM FILLED POCKET
MIN 1" (25.4 mm) OR AS
SPECIFIED
DRILL-TEC
™
FASTENERS
AND PLATES 12" (305 mm) O.C.
(FOR BALLASTED SYSTEMS 6"
[152 mm] O.C.)
ROOF DECK/SUBSTRATE
MULTIPLE LAYERS OF
ENERGYGUARD
™
ROOF INSULATION
TAPERED EDGE STRIP
INSTALL THE EVERGUARD
®
FACTORY-FABRICATED EXPANSION
COVER OUT PAST THE MECHANICAL
ATTACHMENT AND HOT AIR-WELD
REINFORCED EVERGUARD
®
TPO MEMBRANE
ISSUE / REVISION DATEDRAWING #
GAF ●
1 Campus Drive Parsippany, NJ 07054 ● www.gaf.com ● [email protected] ● 800-766-3411
LEGEND
SCALE
N.T.S.
THIS DETAIL APPLIES TO:
ColdStorage
3/1/21
SINGLE-PLY: TPO 60-80 mil membranes
401D
FACTORY FABRICATED EXPANSION JOINT DETAIL
- FLAT TYPE
ADHERED SYSTEMS
MECHANICALLY ATTACHED SYSTEMS
RHINOBOND SYSTEMS
®
ISSUE / REVISION DATEDRAWING #
GAF ●
1 Campus Drive Parsippany, NJ 07054 ● www.gaf.com ● [email protected] ● 800-766-3411
LEGEND
SCALE
N.T.S.
THIS DETAIL APPLIES TO:
ColdStorage
3/8/21
SINGLE-PLY: TPO & PVC 60-80 mil membranes
402D
FIELD FABRICATED EXPANSION JOINT - CURB TYPE
ADHERED SYSTEMS
MECHANICALLY ATTACHED SYSTEMS
RHINOBOND SYSTEMS
HEAT-WELDED
EVERGUARD
®
WATER-BLOCK
EVERGUARD
®
BONDING ADHESIVE
EVERGUARD
®
BONDING ADHESIVE
(OPTIONAL)
WOOD NAILERS MIN. 2" X _"
SECURED TO SUBSTRATE
DRILL-TEC
™
FASTENERS AND PLATES
12" (305 mm) O.C.
1. FIELD FABRICATED EXPANSION JOINT SHOULD BE SMOOTH BACKED MEMBRANE ONLY.
2. FOR STEEL ROOF DECKS: FILL STEEL DECK FLUTES WITH SPRAY FOAM INSULATION PRIOR TO THE INSTALLATION OF ABOVE
DECK INSULATION A MINIMUM OF 12 INCHES (305 mm) FROM EDGE OF EXPANSION JOINT.
NOTE:
BATT INSULATION
ROOF DECK/SUBSTRATE
HEAT-WELDED LAP
BACKER ROD 1-1/2 TIMES THE OPENING.
SECURE MEMBRANE AT TOP OF CURB WITH
RING SHANK ROOFING NAILS 12" (305 mm) O.C.
FOAM FILLED POCKET MIN 1" (25.4 mm)
OR AS SPECIFIED
REINFORCED EVERGUARD
®
MEMBRANE
MULTIPLE LAYERS OF ENERGYGUARD
™
ROOF
INSULATION, STAGGERED AND OFFSET
REINFORCED EVERGUARD
®
MEMBRANE
HEAT-WELDED LAP
REINFORCED EVERGUARD
®
MEMBRANE
®
ISSUE / REVISION DATEDRAWING #
GAF ●
1 Campus Drive Parsippany, NJ 07054 ● www.gaf.com ● [email protected] ● 800-766-3411
LEGEND
SCALE
N.T.S.
THIS DETAIL APPLIES TO:
ColdStorage
3/8/21
SINGLE-PLY: TPO & PVC 60-80 mil membranes
402E
FACTORY FABRICATED EXPANSION JOINT - CURB TYPE
ADHERED SYSTEMS
MECHANICALLY ATTACHED SYSTEMS
RHINOBOND SYSTEMS
HEAT-WELDED
EVERGUARD
®
WATER-BLOCK
EVERGUARD
®
BONDING ADHESIVE
EVERGUARD
®
BONDING ADHESIVE
(OPTIONAL)
WOOD NAILERS MIN. 2" X _"
SECURED TO SUBSTRATE
DRILL-TEC
™
FASTENERS AND PLATES
12" (305 mm) O.C.
1. SEE EVERGUARD DETAIL 330 FOR LAP APPLICATION.
2. FOR STEEL ROOF DECKS: FILL STEEL DECK FLUTES WITH SPRAY FOAM INSULATION PRIOR TO THE INSTALLATION OF ABOVE
DECK INSULATION A MINIMUM OF 12 INCHES (305 mm) FROM EDGE OF EXPANSION JOINT.
NOTE:
BATT INSULATION
ROOF DECK/SUBSTRATE
HEAT-WELDED LAP
SECURE MEMBRANE AT TOP OF CURB WITH
RING SHANK ROOFING NAILS 12" (305 mm) O.C.
FOAM FILLED POCKET MIN 1" (25.4 mm)
OR AS SPECIFIED
MULTIPLE LAYERS OF ENERGYGUARD
™
ROOF
INSULATION, STAGGERED AND OFFSET
REINFORCED EVERGUARD
®
MEMBRANE
HEAT-WELDED LAP
TACK WELD INTERMITTENTLY ON BOTH
CURBS TO HOLD IN PLACE IF NEEDED
WHILE INSTALLING
FACTORY FABRICATED EVERGUARD
®
TPO
EXPANSION JOINT COVER
FOAM EXTENDS
2" (52 mm) INTO
OPENING
REINFORCED EVERGUARD
®
MEMBRANE
®
NOTE:
1. FIELD-FABRICATED EXPANSION JOINT SHOULD USE A SMOOTH BACKED MEMBRANE.
2. FOR STEEL ROOF DECKS: FILL STEEL DECK FLUTES WITH SPRAY FOAM INSULATION PRIOR TO THE INSTALLATION OF ABOVE
DECK INSULATION A MINIMUM OF 12 INCHES (305 mm) FROM FACE OF WALL
FOAM FILLED POCKET MIN 1" (25.4 mm) OR
AS SPECIFIED
MULTIPLE LAYERS OF
ENERGYGUARD
™
ROOF
INSULATION, STAGGERED
AND OFFSET
ROOF DECK/SUBSTRATE
ISSUE / REVISION DATEDRAWING #
GAF ●
1 Campus Drive Parsippany, NJ 07054 ● www.gaf.com ● [email protected] ● 800-766-3411
LEGEND
SCALE
N.T.S.
THIS DETAIL APPLIES TO:
ColdStorage
3/8/21
SINGLE-PLY: TPO & PVC 60-80 mil membranes
403D
FIELD FABRICATED WALL EXPANSION JOINT - FLAT TYPE
ADHERED SYSTEMS
MECHANICALLY ATTACHED SYSTEMS
RHINOBOND SYSTEMS
HEAT-WELDED
EVERGUARD
®
BONDING ADHESIVE
HEAT-WELDED
LAP
EVERGUARD
®
BONDING ADHESIVE
WOOD NAILERS MIN. 2" X _" SECURED TO
SUBSTRATE
REFERENCE EVERGUARD
®
PARAPET WALL
& CURB FLASHING DETAILS (300 SERIES)
FOR WALL OR CURB TERMINATION
REINFORCED EVERGUARD
®
MEMBRANE
REINFORCED EVERGUARD
®
SMOOTH MEMBRANE
DRILL-TEC
™
FASTENERS AND PLATES 12"
(305 mm) O.C.
BATT INSULATION
BACKER ROD
1-1/2 TIMES THE
OPENING
HEAT-WELDED LAP
®
NOTE:
1. FOR STEEL ROOF DECKS: FILL STEEL DECK FLUTES WITH SPRAY FOAM INSULATION PRIOR TO THE INSTALLATION OF ABOVE
DECK INSULATION A MINIMUM OF 12 INCHES (305 mm) FROM FACE OF WALL
FOAM FILLED POCKET MIN 1" (25.4 mm) OR AS SPECIFIED
MULTIPLE LAYERS OF
ENERGYGUARD
™
ROOF
INSULATION, STAGGERED
AND OFFSET
ROOF DECK/SUBSTRATE
ISSUE / REVISION DATEDRAWING #
GAF ●
1 Campus Drive Parsippany, NJ 07054 ● www.gaf.com ● [email protected] ● 800-766-3411
LEGEND
SCALE
N.T.S.
THIS DETAIL APPLIES TO:
ColdStorage
3/29/21
SINGLE-PLY: TPO 60-80 mil membranes
404D
FACTORY FABRICATED WALL EXPANSION JOINT - CURB
TYPE
ADHERED SYSTEMS
MECHANICALLY ATTACHED SYSTEMS
RHINOBOND SYSTEMS
HEAT-WELDED
EVERGUARD
®
BONDING ADHESIVE
HEAT-WELDED
LAP
EVERGUARD
®
BONDING ADHESIVE
WOOD NAILERS MIN. 2" X _" SECURED TO SUBSTRATE
REFERENCE EVERGUARD
®
PARAPET WALL & CURB FLASHING
DETAILS (300 SERIES) FOR WALL OR CURB TERMINATION
REINFORCED EVERGUARD
®
MEMBRANE
DRILL-TEC
™
FASTENERS AND PLATES 12" (305 mm) O.C.
FOAM EXTENDS 3" (76 mm) INTO OPENING
TACK WELD FLANGE INTERMITTENTLY BETWEEN FASTENERS
ADJACENT TO BELLOWS
HEAT-WELDED LAP
FACTORY FABRICATED EVERGUARD
®
TPO EXPANSION
JOINT COVER
SECURE MEMBRANE AT TOP WITH RING SHANK ROOFING NAILS
12" (305 mm) O.C.
BASE FLASHING MEMBRANE SHOULD RUN INTO EXPANSION
JOINT AND CONTINUE UP THE WALL AND TERMINATE AS
INDICATED
BATT INSULATION
®
ISSUE / REVISION DATEDRAWING #
GAF ●
1 Campus Drive Parsippany, NJ 07054 ● www.gaf.com ● [email protected] ● 800-766-3411
LEGEND
SCALE
N.T.S.
THIS DETAIL APPLIES TO:
ColdStorage
3/1/21
SINGLE-PLY: TPO & PVC 60-80 mil membranes
503C
TERMINATION AT R.T.U. DETAIL WITH WELDED LAP
ADHERED SYSTEMS
MECHANICALLY ATTACHED SYSTEMS
RHINOBOND SYSTEMS
FOAM FILLED POCKET MIN 1" (25.4 mm)
OR AS SPECIFIED
R.T.U.
FASTENERS AT 12" (305 mm) O.C. MAX
INSULATED METAL CURB
WOOD NAILER THICKNESS OF INSULATION
ENERGYGUARD
™
ROOF INSULATION
DRILL-TEC
™
FASTENERS 12" (305 mm) O.C.
MULTIPLE LAYERS OF
ENERGYGUARD
™
ROOF INSULATION
ROOF DECK/SUBSTRATE
REFERENCE EVERGUARD
®
PARAPET WALL & CURB
FLASHING DETAILS (300 SERIES) FOR BASE TERMINATION
REINFORCED EVERGUARD
®
MEMBRANE
WOOD NAILERS MIN. 2" X _"
HEAT-WELDED
NOTE:
1. FOR STEEL ROOF DECKS: FILL STEEL DECK FLUTES WITH SPRAY FOAM INSULATION PRIOR TO THE INSTALLATION OF ABOVE
DECK INSULATION A MINIMUM OF 12 INCHES (305 mm) FROM FACE OF OPENING.
®
ISSUE / REVISION DATEDRAWING #
GAF ●
1 Campus Drive Parsippany, NJ 07054 ● www.gaf.com ● [email protected] ● 800-766-3411
LEGEND
SCALE
N.T.S.
THIS DETAIL APPLIES TO:
ColdStorage
3/29/21
SINGLE-PLY: TPO & PVC 60-80 mil membranes
505B
ROOF HATCH DETAIL - AMBIENT INTERIOR CONDITIONS
ADHERED SYSTEMS
MECHANICALLY ATTACHED SYSTEMS
RHINOBOND SYSTEMS
FOAM FILLED POCKET MIN 1" (25.4 mm) OR AS SPECIFIED
DRILL-TEC
™
FASTENERS 12" (305 mm) O.C.
ROOF DECK/SUBSTRATE
REINFORCED EVERGUARD
®
MEMBRANE
WOOD NAILERS MIN. 2" X _"
NOTE:
1. FOR STEEL ROOF DECKS: FILL STEEL DECK FLUTES WITH SPRAY FOAM INSULATION PRIOR TO THE INSTALLATION OF ABOVE
DECK INSULATION A MINIMUM OF 12 INCHES (305 mm) FROM FACE OF OPENING.
WALKWAY PAD REQUIRED
AT ROOF ACCESS
ROOF HATCH BY OTHERS
MEMBRANE MUST BE ON THREE SIDES OF HATCH OPENING
SOLID BACKER ROD 50% LARGER THAN OPENING
8" (203 m
m) M
IN
.
MULTIPLE LAYERS OF ENERGYGUARD
™
ROOF INSULATION,
STAGGERED AND OFFSET
HEAT-WELDED
EVERGUARD
®
BONDING ADHESIVE
EVERGUARD
®
BONDING ADHESIVE
[12" (305 mm) OR MORE OF INSULATION]
®
HEAT-WELDED
FLEXSEAL
™
CAULK GRADE SEALANT
NOTE:
1. DO NOT CUT SIDE OF PREMOLDED BOOT. IT MUST BE PULLED OVER VENT PIPE.
2. IF THE PLATES AND FASTENERS INTRUDE INTO BOOT FLANGE AREA, THEN A TARGET MUST FIRST BE INSTALLED OVER
PLATES AND FASTENERS BEFORE BOOT INSTALLATION.
2" (52 mm)
2" (52 mm)
ALTERNATE INSTALLATION
SEE NOTE #2
TARGET MADE FROM REINFORCED
EVERGUARD
®
MEMBRANE
EVERGUARD
®
PREMOLDED VENT BOOT
VENT STACK
EVERGUARD
®
WATER BLOCK OR
FLEXSEAL
™
CAULK GRADE SEALANT
STAINLESS
STEEL CLAMP
EVERGUARD
®
PREMOLDED VENT BOOT
REINFORCED
EVERGUARD
®
MEMBRANE
MULTIPLE LAYERS OF
ENERGYGUARD
™
ROOF
INSULATION
FOAM FILLED POCKET MIN 1"
(25.4 mm) OR AS SPECIFIED
ROOF DECK/SUBSTRATE
DRILL-TEC
™
PLATES
& FASTENERS
4 PER PENETRATION
ISSUE / REVISION DATEDRAWING #
GAF ●
1 Campus Drive Parsippany, NJ 07054 ● www.gaf.com ● [email protected] ● 800-766-3411
LEGEND
SCALE
N.T.S.
THIS DETAIL APPLIES TO:
ColdStorage
3/1/21
SINGLE-PLY: TPO & PVC 60-80 mil membranes
506B
PREMOLDED VENT BOOT FLASHING DETAIL - AMBIENT
INTERIOR CONDITIONS
ADHERED SYSTEMS
MECHANICALLY ATTACHED SYSTEMS
RHINOBOND SYSTEMS
®
FOAM FILLED POCKET
MIN 1" (25.4 mm) OR AS SPECIFIED
ISSUE / REVISION DATEDRAWING #
GAF ●
1 Campus Drive Parsippany, NJ 07054 ● www.gaf.com ● [email protected] ● 800-766-3411
LEGEND
SCALE
N.T.S.
THIS DETAIL APPLIES TO:
ColdStorage
3/1/21
SINGLE-PLY: TPO & PVC 60-80 mil membranes
506C
INSULATED PIPE PENETRATION DETAIL WITH FLASHING
TO PIPE
ADHERED SYSTEMS
MECHANICALLY ATTACHED SYSTEMS
RHINOBOND SYSTEMS
8" (203 m
m)
STAINLESS
STEEL CLAMP
PIPE PENETRATION
MULTIPLE LAYERS OF
ENERGYGUARD
™
ROOF INSULATION
REINFORCED
EVERGUARD
®
MEMBRANE
EVERGUARD
®
WATER
BLOCK OR FLEXSEAL
™
CAULK GRADE SEALANT
EVERGUARD
®
DETAIL
MEMBRANE OR SPLIT
BOOT
REFERENCE EVERGUARD
®
ROOF PENETRATION
DETAILS (SERIES 500) FOR
FLASHING DETAILS
FLEXSEAL
™
CAULK
GRADE SEALANT
PIPE INSULATION AND
INSULATION JACKET
INSTALLED OVER
FLASHING
(SHOWN DASHED)
ROOF
DECK/SUBSTRATE
HEAT-WELDED
EVERGUARD
®
WATER-BLOCK
EVERGUARD
®
BONDING ADHESIVE
EVERGUARD
®
BONDING
ADHESIVE
®
FOAM FILLED POCKET
MIN 1" (25.4 mm) OR AS
SPECIFIED
ISSUE / REVISION DATEDRAWING #
GAF ●
1 Campus Drive Parsippany, NJ 07054 ● www.gaf.com ● [email protected] ● 800-766-3411
LEGEND
SCALE
N.T.S.
THIS DETAIL APPLIES TO:
ColdStorage
3/1/21
SINGLE-PLY: TPO & PVC 60-80 mil membranes
506D
INSULATED PIPE PENETRATION DETAIL WITH FLASHING
TO PIPE INSULATION
ADHERED SYSTEMS
MECHANICALLY ATTACHED SYSTEMS
RHINOBOND SYSTEMS
8" (203 m
m)
PIPE PENETRATION
MULTIPLE LAYERS OF
ENERGYGUARD
™
ROOF
INSULATION
REINFORCED
EVERGUARD
®
MEMBRANE
EVERGUARD
®
WATER
BLOCK OR FLEXSEAL
™
CAULK GRADE SEALANT
EVERGUARD
®
DETAIL
MEMBRANE OR SPLIT
BOOT
REFERENCE
EVERGUARD
®
ROOF
PENETRATION DETAILS
(SERIES 500) FOR FLASHING
DETAILS
FLEXSEAL
™
CAULK
GRADE SEALANT
PIPE INSULATION
JACKET INSTALLED
OVER FLASHING AND
PIPE INSULATION
ROOF
DECK/SUBSTRATE
PIPE INSULATION
CONTINUOUS THROUGH
ROOF DECK
HEAT-WELDED
EVERGUARD
®
WATER-BLOCK
EVERGUARD
®
BONDING ADHESIVE
EVERGUARD
®
BONDING
ADHESIVE
®
ISSUE / REVISION DATEDRAWING #
GAF ●
1 Campus Drive Parsippany, NJ 07054 ● www.gaf.com ● [email protected] ● 800-766-3411
LEGEND
SCALE
N.T.S.
THIS DETAIL APPLIES TO:
ColdStorage
3/1/21
SINGLE-PLY: TPO & PVC 60-80 mil membranes
511B
EXPOSED WOOD EQUIPMENT SUPPORT SLEEPER DETAIL
ADHERED SYSTEMS
MECHANICALLY ATTACHED SYSTEMS
RHINOBOND SYSTEMS
ROOF
DECK/SUBSTRATE
MULTIPLE LAYERS OF
ENERGYGUARD
™
ROOF
INSULATION
REINFORCED
EVERGUARD
®
MEMBRANE
WOOD SLEEPER
FOAM FILLED POCKET
MIN 1" (25.4 mm) OR AS
SPECIFIED
WOOD BLOCKING
EQUIPMENT SUPPORT
STAND
EVERGUARD
®
WALKWAY PAD OR
MEMBRANE PROTECTION PLY,
CONTINUOUS UNDER SLEEPER
®
EVERGUARD
®
WATER BLOCK
EVERGUARD
®
BONDING ADHESIVE
ISSUE / REVISION DATEDRAWING #
GAF ●
1 Campus Drive Parsippany, NJ 07054 ● www.gaf.com ● [email protected] ● 800-766-3411
LEGEND
SCALE
N.T.S.
THIS DETAIL APPLIES TO:
ColdStorage
4/6/21
SINGLE-PLY: TPO 60-80 mil membranes
609C
TPO TO EXISTING EPDM - NONADHERED
ADHERED SYSTEMS
MECHANICALLY ATTACHED SYSTEMS
RHINOBOND SYSTEMS
NOTE:
1. GAF DOES NOT GUARANTEE THE WATERTIGHT INTEGRITY OF TIE-INS TO OTHER MEMBRANE ROOF SYSTEMS.
2. WOOD BLOCKING MUST BE SEALED TO THE DECK. IF STEEL DECK, ALL LOWER FLUTES MUST BE SEALED TO PREVENT
WATER FROM GOING PAST THIS DETAIL UNDER THE ROOF.
3. FOR STEEL ROOF DECKS: FILL STEEL DECK FLUTES WITH SPRAY FOAM INSULATION PRIOR TO THE INSTALLATION OF
ABOVE DECK INSULATION A MINIMUM OF 12 INCHES (305 mm) FROM WOOD NAILER ON NEW TPO SIDE OF ROOF.
EXISTING EPDM
WOOD NAILERS,
MIN 2" X _"
ROOF DECK/SUBSTRATE
MULTIPLE LAYERS OF
ENERGYGUARD
™
ROOF
INSULATION, STAGGERED
AND OFFSET
REINFORCED EVERGUARD
®
TPO MEMBRANE
DRILL-TEC
™
TERMINATION BAR FASTENED 12" (305 mm)
3" (76 mm) EPDM SEAM TAPE AND PRIMER BY OTHERS
EVERGUARD
®
TPO COVER TAPE OVER SURFACE
PRIMED WITH EVERGUARD
®
TPO PRIMER
FOAM FILLED POCKET MIN 1"
(25.4 mm) OR AS SPECIFIED
EVERGUARD
®
WATER BLOCK