clic ni acquisition and control module update

18
CLIC NI Acquisition and Control Module update CLIC Module Working group meeting 3-10-2013 Adriaan Rijllart EN-ICE-MTA

Upload: dmitri

Post on 06-Feb-2016

52 views

Category:

Documents


0 download

DESCRIPTION

CLIC NI Acquisition and Control Module update. CLIC Module Working group meeting 3-10- 2013 Adriaan Rijllart EN-ICE-MTA. Content. CLIC ACM requirements Motivation for NI systems Inventory of signals Prototype system proposal Miniaturisation Planning Summary. ACM requirements. - PowerPoint PPT Presentation

TRANSCRIPT

Page 1: CLIC NI Acquisition and Control Module update

CLICNI Acquisition and Control Module

update

CLIC Module Working group meeting

3-10-2013

Adriaan RijllartEN-ICE-MTA

Page 2: CLIC NI Acquisition and Control Module update

CMWG - A. Rijllart 2

ContentCLIC ACM requirements

Motivation for NI systems

Inventory of signals

Prototype system proposal

Miniaturisation

Planning

Summary

3/10/2013

Page 3: CLIC NI Acquisition and Control Module update

CMWG - A. Rijllart 3

ACM requirements

23000 modules-2m length-200 signals/module- details in excel file- large variety of signal sources (18 GHz wakefield monitor to DC temperature sensors or flow-meters)- requested readout speed: up to 100 Hz- single value readouts or vector readouts- FE electronics needs external timing reference with ps stability

Standard industrial solution with crates and individual modules will explode available budget

TDR phase of CLIC (2011-2016) will seek industrial “custom solution”

3/10/2013

Page 4: CLIC NI Acquisition and Control Module update

CMWG - A. Rijllart 4

Motivation for NI-PXI systems

Industrial standard

Hardware and software made to work together

Large offer

600 alliance partners world wide

Good support

3/10/2013

Page 5: CLIC NI Acquisition and Control Module update

CMWG - A. Rijllart 5

Inventory of signals

3/10/2013

Ch type S-rate [S/s]

Resolution [bits]

# ch # ch + bu

V. Fast ADC 2 G 8 0 0

Fast ADC 200 M 14 28 48

Slow ADC 1 k 16 105 160

Slow DAC 1 k 18 8 32

Raw DIO 1 k 146 256

Serial I/O 14 32

Total 301 528

Page 6: CLIC NI Acquisition and Control Module update

CMWG - A. Rijllart 6

NI DAQ modules

3/10/2013

Ch type S-rate [S/s] Spec/NI

Resolution [bits]

Spec/NI

Module type

# ch/mo

d

Price($)/ch

U. fast ADC

5 G 10 PXIe-5162

4 4100

V. fast ADC

2 G 8 PXI-5153 2 3300

Fast ADC 200 M (250 M)

14 NI 5761R 4 3200

Slow ADC 1 k (3 k) 16 PXI-6225 40/80 40/20

Slow DAC 1 k (8 k) 18 (16) PXI-6225 2 free

Raw DIO 1 k (1 M) PXI-6225 24 free

PXIe-6535

32 50

Serial I/O NI 6584 16 180

Page 7: CLIC NI Acquisition and Control Module update

CMWG - A. Rijllart 7

NI system proposal

3/10/2013

Ch type S-rate [S/s]

NI

Resolution

[bits] NI

#ch

Module type NI

# ch NI

# NI modules

V. Fast ADC

2 G 8 0 PXI-5153 0 0

Fast ADC 200 M (250 M)

14 28 NI 5761R 28 7

Slow ADC

1 k (3 k) 16 105 PXI-6225 160 4

Slow DAC 1 k (8 k) 18 (16) 8 PXI-6225 8 4*

Raw DIO 1 k (1 M)

146 PXI-6225 96 4*

PXIe-6535 64 2

Serial I/O 14 NI 6584 16 1

Total 372 * Included

Page 8: CLIC NI Acquisition and Control Module update

CMWG - A. Rijllart 8

NI system cost

3/10/2013

Ch type Module NI

# ch NI

# NI mod Cost $/mod

Cost $

V. Fast ADC PXI-5153 0 0 7500 0

Fast ADC NI 5761R 28 7 12300 86100

Slow ADC PXI-6225 160 4 2000 8000

Slow DAC PXI-6225 8 4* *

Raw DIO PXI-6225 96 4* *

PXIe-6535 64 2 2000 4000

Serial I/O NI 6584 16 1 7500 7500

Crate PXIe-1085 1 8500 8500

Controller – FPGA + fibre

PXIe-PCIe8375

1 5500 5500

PC 800

Total 372 * Included 120400

Page 9: CLIC NI Acquisition and Control Module update

CMWG - A. Rijllart 9

NI system overview

3/10/2013

Fast ADC DIO + Slow ADC + DAC

DIO SerialSynchroIEEE-1588

Controller

Page 10: CLIC NI Acquisition and Control Module update

CMWG - A. Rijllart 10

FlexRIO architecture

3/10/2013

Page 11: CLIC NI Acquisition and Control Module update

CMWG - A. Rijllart 11

FPGA controllerFiber-Optic MXI-Express x4 link, PXIe-PCIe8375

838 MB/s sustained transfer rate

Remote control of PXIe crate

Cost 5.5 kCHF

3/10/2013

Page 12: CLIC NI Acquisition and Control Module update

CMWG - A. Rijllart 12

Next steps NI-ACM

Functional validation (DAQ, timing, data transfer)

Purchase system with FPGA based controller

Communication test with optical fibre (length)

Validate on Module Test Stand

Develop White Rabbit FPGA controller

Radiation resistance test?Controller + DAQ boards

3/10/2013

Page 13: CLIC NI Acquisition and Control Module update

CMWG - A. Rijllart 13

White Rabbit-FPGA controller

Development by NIWhite Rabbit timing signal decoding

Loop back in the daisy chain

Estimated cost 25 kCHF

• The White Rabbit timing should be decoded on the FPGA

• The loop back mechanism should be implemented, if we want to be protected from a single fibre fault

3/10/2013

Page 14: CLIC NI Acquisition and Control Module update

CMWG - A. Rijllart 14

MiniaturisationFinal system requirements:

cheap

consuming little power

easy cooling (conduction?)

small

Solution:Miniaturise 15 boards into 1 small box

NI has long experience with custom design

3/10/2013

Page 15: CLIC NI Acquisition and Control Module update

CMWG - A. Rijllart 15

CMW integrationOASIS compatibility

Choices: FESA 3

Lightweight CMW client

A short study needed to compare the 2 solutions

3/10/2013

Page 16: CLIC NI Acquisition and Control Module update

CMWG - A. Rijllart 16

NI-ACM (+ RF) Planning

Year Personnel Material Work Packages

2013 0.2 CERN staff1.0 NI consultant

120 kCHF 5 kCHF

25 kCHF 

130 kCHF

Prototype NI-ACMFibre controller with 100 m fibre

Realisation of the “fibre +” interfaceTest of CLIC module on CTF3

RF measurement systems x42014 0.2 CERN staff

1.0 NI consultant1.0 CLIC fellow

70 kCHF Definition of a single board /highly compact NI-ACMTDR contribution

2015 0.1 CERN staff1.0 CLIC fellow

  Radiation testTDR contribution

2016 0.1 CERN staff   TDR contribution

3/10/2013

Page 17: CLIC NI Acquisition and Control Module update

CMWG - A. Rijllart 17

SummaryNI system can fit the ACM requirements

Miniaturisation can solve the cost, power, cooling and space requirements

Proposed program:Validation of NI-ACM functionality:

120 kCHF

Fibre optic controller: 5 kCHF

WR timing and loop back development: 25 kCHF

3/10/2013

Page 18: CLIC NI Acquisition and Control Module update

CMWG - A. Rijllart 18

Thank you

3/10/2013

Questions?