Prepared for Dominion 5000 Dominion Boulevard Glen Allen, Virginia 23060 COAL COMBUSTION RESIDUALS INITIAL SAFETY FACTOR ASSESSMENT for VIRGINIA ELECTRIC AND POWER COMPANY CHESTERFIELD POWER STATION LOWER ASH POND CHESTERFIELD COUNTY, VIRGINIA Prepared by Geosyntec consultants t 11)',llll't'I' I "('it·111i."'h 111110\'lll(JI', 9211 Arboretum Parkway, Suite 200 Richmond, Virginia 23236 MV1373 October 2016

Upload: others

Post on 03-Dec-2021

0 views

Category:

Documents


0 download

TRANSCRIPT

Prepared for

Dominion 5000 Dominion Boulevard

Glen Allen, Virginia 23060

COAL COMBUSTION RESIDUALS INITIAL SAFETY FACTOR ASSESSMENT

for

VIRGINIA ELECTRIC AND POWER COMPANY CHESTERFIELD POWER STATION

LOWER ASH POND CHESTERFIELD COUNTY, VIRGINIA

Prepared by

Geosyntec consultants

t 11)',llll't'I' I "('it·111i."'h 111110\'lll(JI',

9211 Arboretum Parkway, Suite 200 Richmond, Virginia 23236

MV1373 October 2016

Coal Combustion Residuals Safety Factor Assessment Geosyntec C> Chesterfield Power Station Lower Ash Pond

consultants

TABLE OF CONTENTS

1. CERTIFICATION/STATEMENT OF PROFESSIONAL OPINION ....... .......... .1

2. INTRODUCTION ......... ........ .... ....... .......... .......... ... .............. ...... ... .. ......... .... ... ..... 2

3. PURPOSE............ .................................................................................................. 2

4. FACTOR OF SAFETY ASSESSMENT REQUIREMENTS ...............................2

5. FACTOR OF SAFETY ASSESSMENT ................................ ........ ... ... .. .... .... ..... ..3 5.1 Long-Term Maximum Storage Pool Loading Condition .... ... ..... ............ ... ..4

5.2 Maximum Surcharge Pool Loading Conditions ....................... ............. ...... .4

5.3 Seismic Factor of Safety...............................................................................5

5.4 Liquefaction Factor of Safety ........... .... ... .. ... ..... .......... ................... ............ ..5

6. CONCLUSION .. ..... .. ....... ... ................... ..... ... .... .............. ... ..................................5

7. REFERENCES ......................................................................................................5

LIST OF APPENDICES

Appendix A Slope Stability Results

CCR LAP Safety Factor Assessment Final October 2016

Coal Combustion Residuals Safety Factor Assessment Geosyntec C> Chesterfield Power Station Lower Ash Pond

consultants

1. CERTIFICATION/STATEMENT OF PROFESSIONAL OPINION

The Initial Safety Factor Assessment for the Chesterfield Power Station Lower Ash Pond was prepared by Geosyntec Consultants, Inc. (Geosyntec ). The Assessment was based on certain information that, other than for information Geosyntec originally prepared, Geosyntec has relied on but not independently verified. This Certification/Statement of Professional Opinion is therefore limited to the information available to Geosyntec at the time the Assessment was written. On the basis of and subject to the foregoing, . it is my professional opinion as a Professional Engineer licensed in the Commonwealth of Virginia that the Assessment has been prepared in accordance with good and accepted engineering practices as exercised by other engineers practicing in the same discipline(s), under similar circumstances, at the same time, and in the same locale. It is my professional opinion that the Assessment was prepared consistent with the requirements of Section 257.73(e) of the United States Environmental Protection Agency's "Disposal of Coal Combustion Residuals From Electric Utilities," published in the Federal Register on April 17, 2015 with an effective date of October 19, 2015 (40 CFR 257 Subpart D).

The use of the words "certification" and/or "certify" in this document shall be interpreted and construed as a Statement of Professional Opinion and is not and shall not be interpreted or construed as a guarantee, warranty or legal opinion.

Geosyntec Consultants, Inc.

1it:li,TH i~ · NNETH • SHERIDAN

\ 1 Lie. No. 045360 fJ,; •

•oA ,i!;I •• ~& e:,<f:~!

•••••••••• 810NAL~ e•

Scott Sheridan, P .E. Principal

•••••••o;•:;\

CCR LAP Safety Factor Assessment Final October 2016

Coal Combustion Residuals Factor of Safety Assessment Geosyntec C> Chesterfield Power Station Lower Ash Pond

consultants

2. INTRODUCTION

The Chesterfield Power Station (Station) is owned by Virginia Electric and Power Company d/b/a Dominion Virginia Power (Dominion) and is located in Chesterfield County, Virginia. The Station includes the Lower Ash Pond (LAP) impoundment, which is a component of the Station's wastewater treatment system utilized to manage and settle solids, including CCRs.

The LAP is located on Dominion property at the Chesterfield Power Station in Chesterfield County, Virginia (coordinates 37.3737° North and 77.3795° West) and is bounded by the Old Channel of the James River and the Upper Pond on the south, Henricus Park Road on the east, Coxendale Road on the north, and the thermal channel to the west.

The LAP is regulated as an existing CCR surface impoundment under the Environmental Protection Agency's "Standards for the Disposal of Coal Combustion Residuals in Landfills and Surface Impoundments" [ 40 CFR 257 Subpart D] published in the Federal Register on April 17, 2015 with an effective date of October 19, 2015 (CCR Rule).

3. PURPOSE

This Initial Safety Factor Assessment (Assessment) 1s prepared pursuant to § 257.73(e)(l) of the CCR Rule [40 CFR § 257.73(e)(l)].

4. FACTOR OF SAFETY ASSESSMENT REQUIREMENTS

In accordance with § 257.73(e)(l), a CCR surface impoundment owner or operator "must conduct initial and periodic safety factor assessments for each CCR unit and document whether the calculated factors of safety for each CCR unit achieve the minimum safety factor for the critical cross section of the embankment."

Furthermore, § 257.73(e)(l) requires that safety assessments be conducted for the following conditions of the impoundment and that the safety factor assessments be supported by appropriate engineering calculations:

• The calculated static factor of safety under the long-term, maximum storage pool loading condition must equal or exceed 1.50;

CCR LAP Safety Factor Assessment Final 2 October 2016

Coal Combustion Residuals Factor of Safety Assessment Geosyntec t> Chesterfield Power Station Lower Ash Pond

consultants

• The calculated static factor of safety under the maximum surcharge pool loading condition must equal or exceed 1 .40;

• The calculated seismic factor of safety must equal or exceed 1.00; and

• For dikes constructed of soils that are susceptible to liquefaction, the calculated liquefaction factor of safety must equal or exceed 1.20.

This Assessment will document the factors of safety for the LAP as required by § 257.73(e)(l).

5. FACTOR OF SAFETY ASSESSMENT

The LAP receives CCR sluice water and other low volume wastewater streams from the Station. The western side of the LAP is operated to manage and settle solids prior to discharge of ponded surface water through the outfall structure. The LAP embankment along the western side of the pond, near the outfall, was determined to be the critical section for purposes of this Assessment. The material strength parameters used in the analyses were obtained from the Field Investigation and Laboratory Testing Report (Geosyntec, 2016a) which provides a compilation of historic and recent subsurface exploration and laboratory testing programs. The phreatic surface used in the analyses was dependent on the condition being assessed and is discussed for each analysis.

The factors of safety calculated for each condition are summarized in Table 1 and are summarized below.

Table 1 Calculated Factors of Safety

Factor of Safety Condition Minimum Factor of Safety Calculated Factor of Safety

Long-term, maximum storage pool loading

1.50 1.67

Maximum surcharge pool loading 1.40 1.44

Seismic factor of safety 1.00 1.03

Liquefaction factor of safety 1.20 1.21

Calculations results are included in Appendix A.

CCR LAP Safety Factor Assessment Final 3 October 2016

Coal Combustion Residuals Factor of Safety Assessment Geosyntec t> Chesterfield Power Station Lower Ash Pond

consultants

5.1 Critical Cross Sections

The critical cross sections are those on the western embankments (adjacent to the thermal channel) and the southern embankment. In the stability calculation package, Cross Sections B, D and E are identified as the critical cross sections: B is the critical cross section for liquefaction, D is the critical cross section for the maximum surcharge pool loading and E is the critical cross section for the drained and seismic conditions. Both cross sections have Factors of Safety within 10% of each other in all scenarios. The potential failure surfaces occur through the upper embankment and the lower embankment (Old Aiken Marsh Islet) layers, which consist of sandy silts and low and high plasticity clays; thus, these layers are considered the critical layers of the embankment.

5.2 Long-Term Maximum Storage Pool Loading Condition

According to the preamble of the CCR Rule, Section E.3.b.ii.b, the maximum storage pool loading is "the maximum water level that can be maintained that will result in full development of a steady-state seepage condition." The Rule goes on to state that "the maximum storage pool loading needs to consider a pool elevation in the CCR unit that is equivalent to the lowest elevation of the invert of the spillway, i.e., the lowest overflow point of the perimeter of the embankment."

Ponded surface water from the LAP is discharged through a concrete outfall structure. The weir in the outfall structure is maintained at elevation 15.8 feet, and the normal pool elevation in the LAP is 16 feet; therefore, the long term maximum storage pool loading condition will have a phreatic surface elevation of 16 feet. The phreatic surface through the embankment is based on piezometric data collected as part of geotechnical investigations described in Geosyntec, 2016a. The thermal channel water surface varies slightly due to tidal fluctuations; however, the water surface elevation is typically 4 feet.

The calculated static factor of safety is 1.67 for the embankment and meets the requirement for the long term maximum storage pool condition (1.50).

5.3 Maximum Surcharge Pool Loading Conditions

The water elevation for the maximum surcharge pool loading condition is based on the 1,000-year flood event. Based on the design storm, the phreatic surface was modeled to be elevation 18 feet (Geosyntec, 2016b ). The calculated static factor of safety is 1.44 for

CCR LAP Safety Factor Assessment Final 4 October 2016

Coal Combustion Residuals Factor of Safety Assessment Geosyntec e> Chesterfield Power Station Lower Ash Pond

consultants

the embankment and meets the requirement for the maximum surcharge pool condition (1.40).

5.4 Seismic Factor of Safety

The seismic factor of safety was analyzed with a seismic loading event with a 2% probability of exceedance in 50 years, based on United States Geological Survey (USGS) seismic hazard maps. A peak ground acceleration of 0.128g was used in the analyses (Geosyntec, 2016c).

The long term maximum storage pool loading condition was evaluated under seismic conditions. The calculated factor of safety of 1.03 for the embankment and meets the requirement for the maximum surcharge pool condition (1.00).

5.5 Liquefaction Factor of Safety

The liquefaction assessment includes an analysis of potentially liquefiable soils followed by a slope stability analysis using the residual shear strengths that result from a liquefied soil layer. Liquefaction analyses used boring logs from previous subsurface investigations and a design earthquake with a magnitude of 5.7. The calculated factor of safety of 1.21 for the soils in the embankment (Youd, 2001) meets the requirement (1.20).

6. CONCLUSION

In Geosyntec' s opinion, the LAP meets or exceeds the minimum factors of safety as required by§ 257.73(e)(l).

7. REFERENCES

Duncan, J.M. and Steven C. Wright (2005). "Soil Strength and Slope Stability", Hoboken, New Jersey. pp. 79.

Environmental Protection Agency (EPA) (2015). "Hazardous and Solid Waste Management System; Disposal of Coal Combustion Residuals from Electric Utilities; Final Rule. 40 CFR Parts 257 and 261: Part II. EPA-HQ-RCRA­2009- 0640; FRL-9919-44-OSWER.

Geosyntec Consultants Inc. Field Investigation and Laboratory Testing Report, Lower Ash Pond, Chesterfield Power Station, Chesterfield County, Virginia. 2016a.

CCR LAP Safety Factor Assessment Final 5 October 2016

Coal Combustion Residuals Factor of Safety Assessment Geosyntec C> Chesterfield Power Station Lower Ash Pond

consultants

Geosyntec Consultants Inc. Coal Combustion Residuals Inflow Design Flood Control System Plan, Lower Ash Pond, Chesterfield Power Station, Chesterfield County, Virginia. 2016b.

Geosyntec Consultants, 2016. Memorandum - LAP and L VWWTS Seismic Design Data Analysis. May 3, 2016c.

United States Environmental Protection Agency, 2015. 40 CFR Parts 257 and 261 Hazardous and Solid Waste Management System; Disposal ofCoal Combustion Residualsfrom Electric Utilities,· Final Rule. April 17, 2015.

Youd, T.L. et. al. "Liquefaction Resistance of Soils: Summary Report from the 1996 NCEER and 1998 NCEER/NSF Workshops on Evaluation of Liquefaction Resistance of Soils." Journal of Geotechnical and Geoenvironmental Engineering. October 2001: 817-83 3.

CCR LAP Safety Factor Assessment Final 6 October 2016

APPENDIX A

SLOPE STABILITY RESULTS

C 0 C § '-' 0

A

B

C

D

JsE ' "' ~ ~ ~ ~

N ,-~

0 ('. 0 ~

" ~ ' " " 0

I " 5 >

" i"

"" I

~ 0 w ;", ~ w ~ ~

" > ::1F N

> 3, z 0 z "' 0 0

I

:l w C: ~

~ w I '-' 5-

-

· B-1A1

'<1~/ _ GSC-24 FFP-GSG-24

SJ •c, B(~

c7 =~ E-SPT6

o(;/; 0 (? (11

E-SPT1

'~Jl\\ E-SPT2

=

\ W\l 0

1 •

/o -~ ~ .. : , :~--~ 0

Q'.:) Q • ••

0

I • 0 .

REV

TITLE:

PROJECT:

SITE:

( SIGNATURE

DATE

J LEGEND

B-1A-4- - EXISTING SPT

GSB-1-4- - AS-BUILT GEOSYNTEC LAP SPT

GSB-12+ - AS-BUILT GEOSYNTEC LVWWTS SPT

GSC-1 )8( - AS-BUILT GEOSYNTEC LAP CPT

GSC-lF )8( - AS-BUILT GEOSYNTEC LAP FFP CPT

150 300 --0 150

SCALE IN FEET -- -

DESCRIPTION

Geosyntec0 consultants

10220 OLD COI.UIIBIA ROAD, SUllE A COI.UlolllA, IIAR'd.AND 210411 USA

PHONE: 4-10.381.4,l33

DOMINION VIRGINIA POWER CHESlERFIEI.D POWER STATION CHESlER, VIRGINA

CHESTERFIELD POWER STATION CHESTER, VIRGINIA

DESIGNED BY: DATE:

DRAWN BY: JOC PROJECT NO.:

CHECKED BY: FILE:

REVIEWED BY:

APPROVED BY: FIGURE NO.:

A

B

C

D

E

DRN APP

F

.:J -+---------------....... ------------------.----------------,-----------------...-----------------,------------------,------------'------....,..-------...... ---------+-L:\0chesterfield-dom

inion\M

V1222\FIG

URES\G

EO

TECH

SITE IN

V\FIG

6-1.dw

g

CROSS SECTION LOCATIONS

LOWER ASH POND - CCR RULE REQUIREMENTS

September 2016

MV1373-08

KGW

KGW

AutoCAD SHX Text
LOWER ASH POND ACCESS CAUSEWAYS
AutoCAD SHX Text
150
AutoCAD SHX Text
0
AutoCAD SHX Text
150
AutoCAD SHX Text
300
AutoCAD SHX Text
SCALE IN FEET
AutoCAD SHX Text
10220 OLD COLUMBIA ROAD, SUITE A COLUMBIA, MARYLAND 21046 USA PHONE: 410.381.4333
AutoCAD SHX Text
CHESTERFIELD POWER STATION
AutoCAD SHX Text
CHESTER, VIRGINIA
AutoCAD SHX Text
F
AutoCAD SHX Text
E
AutoCAD SHX Text
D
AutoCAD SHX Text
C
AutoCAD SHX Text
B
AutoCAD SHX Text
A
AutoCAD SHX Text
PROJECT:
AutoCAD SHX Text
SITE:
AutoCAD SHX Text
TITLE:
AutoCAD SHX Text
APPROVED BY:
AutoCAD SHX Text
REVIEWED BY:
AutoCAD SHX Text
DRAWING NO.:
AutoCAD SHX Text
OF
AutoCAD SHX Text
DRAWN BY:
AutoCAD SHX Text
DESIGNED BY:
AutoCAD SHX Text
CHECKED BY:
AutoCAD SHX Text
FILE:
AutoCAD SHX Text
PROJECT NO.:
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
DATE
AutoCAD SHX Text
REV
AutoCAD SHX Text
APP
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text
DRN
AutoCAD SHX Text
F
AutoCAD SHX Text
E
AutoCAD SHX Text
D
AutoCAD SHX Text
C
AutoCAD SHX Text
B
AutoCAD SHX Text
A
AutoCAD SHX Text
CHESTERFIELD POWER STATION CHESTER, VIRGINIA
AutoCAD SHX Text
DOMINION VIRGINIA POWER
AutoCAD SHX Text
SIGNATURE
AutoCAD SHX Text
- EXISTING SPT
AutoCAD SHX Text
LEGEND
AutoCAD SHX Text
B-1A
AutoCAD SHX Text
- AS-BUILT GEOSYNTEC LAP SPT
AutoCAD SHX Text
GSB-1
AutoCAD SHX Text
- AS-BUILT GEOSYNTEC LAP CPT
AutoCAD SHX Text
GSC-1
AutoCAD SHX Text
GSC-1F
AutoCAD SHX Text
6-1
AutoCAD SHX Text
MARCH 2016
AutoCAD SHX Text
MV1222
AutoCAD SHX Text
FIG 6-1
AutoCAD SHX Text
DJW
AutoCAD SHX Text
JOC
AutoCAD SHX Text
SUBSURFACE PROFILE LOCATIONS
AutoCAD SHX Text
- AS-BUILT GEOSYNTEC LAP FFP CPT
AutoCAD SHX Text
FIGURE NO.:
AutoCAD SHX Text
- AS-BUILT GEOSYNTEC LVWWTS SPT
AutoCAD SHX Text
GSB-12
AutoCAD SHX Text
L:\0CHESTERFIELD-DOMINION\MV1222\FIGURES\GEOTECH SITE INV\FIG 6-1.DWG~3/30/2016~12:36:42 PM~Jim O'Connor~3/30/2016~12:36:42 PM~Jim O'Connor3/30/2016~12:36:42 PM~Jim O'Connor~12:36:42 PM~Jim O'Connor12:36:42 PM~Jim O'Connor~Jim O'ConnorJim O'Connor
DWoeste
Text Box
2-1
kwarwick
Line
kwarwick
Line
kwarwick
Line
kwarwick
Text Box
B
kwarwick
Text Box
D
kwarwick
Text Box
E
kwarwick
Text Box
1
kwarwick
Line
kwarwick
Line

CROSS SECTION B

-75

-50

-25

025

5075

Safety Factor 0.000 0.250 0.500 1.2081.2081.2081.2081.2081.208 0.750 1.000 1.250 1.500 1.750 2.000 2.250 2.500 2.750 3.000

Post-liquified layer of FGA (only 5-ft thick)3.250 Su_residual = 59 psf640.00 lbs/ft23.500 3.750 4.000 4.250 4.500 4.750 W 5.000 5.250 5.500 5.750 6.000+

1200 1225 1250 Project

1275 1300 1325 1350 1375 1400

Chesterfield Power Station - Lower Ash Pond

1425 1450 1475

SLIDEINTERPRET 7.017

Analysis Description

Drawn By

Date

KGW

10/15/2016

Cross Section B -Po st Liquefaction (Undrained) Scale Company1:359 Geosyntec Consultants

File Name Cross Section B - Post Liquefaction Undrained.slim

CROSS SECTION D

-50

050

100

Safety Factor 0.000 0.250 0.500 0.750 1.000 1.250 1.500 1.750 2.000 2.250 2.500 2.750 3.000 3.250 3.500 3.750

1.4401.4401.4401.4404.000 640.00 lbs/ft2

4.250 4.500 4.750 5.000 5.250 5.500 5.750 6.000+

1275 1300 1325 1350 1375 1400 1425 1450 1475 1500 1525 1550 1575 Project

Analysis Description

Drawn By

Date SLIDEINTERPRET 7.017

Chesterfield Power Station - Lower Ash Pond

Cross Section D -Undrained Scale CompanyDJW 1:387 Geosyntec Consultants

File Name5/25/2016, 5:00:52 PM Cross Section D - Undrained_max pool.slim

kwarwick
Text Box
Cross Section D - Static Undrained Max Pool

CROSS SECTION E

1.6721.6721.6721.672

-50

050

100

150

W

1300 1350 1400 1450 1500 1550 1600 1650 170 Project

Chesterfield Power Station - Lower Ash Pond

Analysis Description Cross Section E -Undrained Drawn By Scale CompanyDJW 1:504 Geosyntec Consultants Date File Name5/25/2016, 5:00:52 PM Cross Section E - Drained.slimSLIDEINTERPRET 7.017

kwarwick
Text Box
Cross Section E - Drained

Safety Factor 0.000 1.0301.0301.0301.030

-100

-5

00

5010

0 0.250 0.1280.500

0.750 1.000 1.250 1.500 1.750 2.000 2.250 2.500 2.750 3.000 3.250 3.500 3.750 4.000 4.250 4.500 4.750 5.000 W 5.250 5.500 5.750 6.000+

1350 1400 Project

1450 1500 1550

Chesterfield Power Station - Lower Ash Pond

1600 1650

Analysis Description Cross Section E -Undrained

SLIDEINTERPRET 7.017

Drawn By

Date

DJW

5/25/2016, 5:00:52 PM

Scale 1:430 Company

File Name

Geosyntec Consultants

Cross Section E - Undrained Seismic.slim

kwarwick
Text Box
Cross Section E - Seismic Undrained