cheemi e catalogue for hall effect sensors

22
Cheemi Technology Co., Ltd Tel: 025-85996365 E-mail: [email protected] www. cheemi-tech.com Cheemi is specialized in development and commercialization of monitoring & measuring solution innovation, with more than 100 workers, 5200 non-dust workshop, 12 years experience in current measurement, ISO, CE & RoSH certificated, one and half hours reach Shanghai port. This is how we keep good quality and competitive prices for global valued customers. Cheemi provides the most effective and reliable sensor solutions which involve Open & Closed Loop Hall Effect Current & Voltage Sensors, Current Transmitter, Leakage Transducer; completely replace LEM hall sensors with excellent quality and performance. Hall Proximity Sensors, Inductive sensors, Photoelectric Proximity Sensors; Equivalent to OMRON Proximity Sensors. Temperature sensors: PT100 series sensor, Temperature Transmitter, Thermocouples/RTD Current Transformers and Potential Transformers For more information, please visit our website: www.cheemi-tech.com

Upload: anna-lei

Post on 18-Feb-2017

106 views

Category:

Automotive


8 download

TRANSCRIPT

Page 1: Cheemi e catalogue for hall effect sensors

Cheemi Technology Co., Ltd

Tel: 025-85996365 E-mail: [email protected] www. cheemi-tech.com

Cheemi is specialized in development and commercialization of monitoring & measuring solutioninnovation, with more than 100 workers, 5200 ㎡ non-dust workshop, 12 years experience incurrent measurement, ISO, CE & RoSH certificated, one and half hours reach Shanghai port. This ishow we keep good quality and competitive prices for global valued customers.

Cheemi provides the most effective and reliable sensor solutions which involve

Open & Closed Loop Hall Effect Current & Voltage Sensors, Current Transmitter, LeakageTransducer; completely replace LEM hall sensors with excellent quality and performance.

Hall Proximity Sensors, Inductive sensors, Photoelectric Proximity Sensors;Equivalent to OMRON Proximity Sensors.

Temperature sensors: PT100 series sensor, Temperature Transmitter, Thermocouples/RTD

Current Transformers and Potential Transformers

For more information, please visit our website: www.cheemi-tech.com

Page 2: Cheemi e catalogue for hall effect sensors

Cheemi Technology Co., Ltd

Tel: 025-85996365 E-mail: [email protected] www. cheemi-tech.com

1.Open Loop Hall Effect Current SensorPrincipleHall Effect Open Loop Current Sensor is a current measurement device which develops on base of the hall effectprinciple, wherein a Hall-effect device(HED) produces an output voltage linearlyrelated to the amplitude and phase of amagnetic field applied to it.

AdvantagesEasy installation

Can be customized

No insertion losses

Low power consumption

Wide current measuring range

High immunity to external interference

2.Closed Loop Hall Effect Current SensorPrincipleHall Effect Close Loop Current Sensor develops on the principles of the Magnetoresistive or Hall effects, and thenull balance or zero magnetic flux method.Primary current Ip provides the magnetic flux which will be balanced by a complementary flux produced by drivinga current through the secondary winding, so the positive and negative magnetic field reaches balance to detect thecurrent.In other words, the secondary current, IS,creates a flux equal in amplitude, but oppositein direction, to the flux created by the primarycurrent.This current can be expressed as avoltage by passing it through a resistor.

AdvantagesHigh accuracy

Very good linearity

Easy installation

Can be customized

Low temperature drift Optimized response time, no insertion losses

Low power consumption High immunity to external interference

Page 3: Cheemi e catalogue for hall effect sensors

Cheemi Technology Co., Ltd

Tel: 025-85996365 E-mail: [email protected] www. cheemi-tech.com

3.Hall Effect Voltage SensorPrincipleThe principles of Hall Voltage Sensor is the same as the closed loop hall current sensor, but need to convert thevoltage of the primary terminal to current through the resistor R1.So the hall voltage sensor is also used to testcurrent signal, and the output compensation current/offset current can accurately reflect the changes of primaryvoltage signal. To select the right R1 value, please choose different sensors based on the test voltage and power.

AdvantagesHigh accuracyVery good linearityEasy installationCan be customizedLow temperature driftHigh immunity to external

interference

4.Current Transmitter/TransducerPrincipleCurrent transmitter is a current measurement device which develops on base of the hall effect principle. It canaccurately measure various types of DC, AC voltage, which is widely used in the electrical power supply,communication power and other fields.

AdvantagesEasy installationCan be customizedNo insertion lossesLow power consumptionWide current measuring rangeHigh immunity to external interference

5.DC Leakage Current TransducerPrincipleDC Leakage Current Sensor develops based on magnetic modulation closed loop principle, to measure tinycurrent (mA level). DC leakage current measuring range can reach 0~±200mA.

Page 4: Cheemi e catalogue for hall effect sensors

Cheemi Technology Co., Ltd

Tel: 025-85996365 E-mail: [email protected] www. cheemi-tech.com

AdvantagesHigh accuracyVery good linearityWide current measuring rangeCan be customizedOptimized response timeLow power

consumptionHigh immunity to external interference

6.Naming rules PART NUMBER CODING

Page 5: Cheemi e catalogue for hall effect sensors

Cheemi Technology Co., Ltd

Tel: 025-85996365 E-mail: [email protected] www. cheemi-tech.com

Hall Effect Current Sensor

Open Loop Hall Current Sensor Single Power Supply

Case Type ModelNominal Current

(RMS)Vout @Ipn

MeasuringRange

SupplyVoltageDC

Accuracy@IPN,+25°C

Mounting(mm)

CHK_BR5S250/100/200/300/4

00/600A2.500±2.0V 0~±600A +5V < ±1.0% 10.5*20.5

CHK_BR12S850/100/200/300/4

00/600A+8.0V 0~+600A +12V < ±1.0% 10.5*20.5

CHK_BR15S450/100/200/300/4

00/600A+4.0V 0~+900A +15V < ±1.0% 10.5*20.5

CHK_BS3S150/100/200/300/4

00/600A1.650±1.250

V0~±600A +3.3V < ±1.0% 10.5*20.5

CHK_BS5S150/100/200/300/4

00/600A2.500±1.0V 0~±900A +5V < ±1.0% 10.5*20.5

CHK_BS5S250/100/200/300/4

00/600A2.500±2.0V 0~±600A +5V < ±1.0% 10.5*20.5

CHK_BS15S450/100/200/300/4

00/600A0.500+4.0V 0~+900A +12–15V < ±1.0% 10.5*20.5

CHK_BS15S4M50/100/200/300/4

00/600A0.500+4.0V 0~+900A +12–15V < ±1.0% 10.5*20.5

CHK_DHAB5S2L 30/300A 2.500±2.0V ±30/±300A +5V < ±1.0% Ø21.55

CHK_E5S250/100/200/300/4

00/600A2.500±2.0V 0~±600A +5V < ±1.0% Ø20.0

CHK_E5S450/100/200/300/4

00/600A+4.0V 0~+600A +5V < ±1.0% Ø20.0

CHK_E12S450/100/200/300/4

00/600A±4.0V 0~+600A +12V < ±1.0% Ø20.0

CHK_EKA5S250/100/200/300/4

00/600A2.500±2.0V 0~±600A +12V < ±1.0% Ø21.0

Page 6: Cheemi e catalogue for hall effect sensors

Cheemi Technology Co., Ltd

Tel: 025-85996365 E-mail: [email protected] www. cheemi-tech.com

CHK_EKB5S2200/400/800/1000/1500/2000A

2.500±2.0V0 ~

±2000A+5V < ±1.0% Ø40.5

CHK_FS5S2200/400/800/1000/1500/2000A

2.500±2.0V0~

±2000A+5V < ±1.0% 12.5*41.0

CHK_HAHE5S2L50/100/200/400/600/800/1000/120

0/1500A2.5V 0~±1500A +5V < ±1.0% 6.5*20.5

CHK_KS5S2400/600/800/1000/1200 /2000A

2.500±2.0V0~

±2000A+5V < ±1.0% 16.0*64.0

CHK_LB5S250/100/200/300A

2.500±2.0V 0~±300A +5V < ±1.0% Ø16.0

CHK_LSP3S1L15/20/25/30A

1.650±1.250V

0~±30A +3.3–5V < ±1.0% Ø8.5

CHK_LSP5S1T15/20/25/30A

1.650±1.0V 0~±38A +5V < ±1.0% Ø8.5

CHK_LSP5S215/20/25/30A

2.500±2.0V 0~±30A +5V < ±1.0% Ø8.5

CHK_LSP5S2L15/20/25/30A

2.500±2.0V 0~±30A +5V < ±1.0% Ø8.5

CHK_LTK5S2100/200/300/600/

800/900A2.500±2.0V 0~±900A +5V < ±1.0% Ø20.0

Open Loop Hall Current Sensor Dual Power Supply

Case Type ModelNominal Current

(RMS)Vout@Ipn

MeasuringRange

SupplyVoltage(DC:V)

Accuracy@IPN,+25°C

Mounting(mm)

CHK_BR15D450/100/200/300/400/

600A±4.0V 0~±900A ±12–15 < ±1.0% 10.5*20.5

CHK_BS15D450/100/200/300/400/

600A±4.0V 0~±900A ±12–15 < ±1.0% 10.5*20.5

CHK_BS15D4H50/100/200/300/400/

600A±4.0V 0~±900A ±12–15 < ±0.5% 10.5*20.5

CHK_DSY15D403/05/10/15/20

/25/30A±4.0V 0~±90A ±12–15 < ±1.0% PCB

CHK_E15D450/100/200/300/400/

600A±4.0V 0~±900A ±12–15 < ±1.0% Ø20.5

Page 7: Cheemi e catalogue for hall effect sensors

Cheemi Technology Co., Ltd

Tel: 025-85996365 E-mail: [email protected] www. cheemi-tech.com

CHK_EKA15D450/100/200/300/400/

600A±4.0V 0~±900A ±12–15 < ±1.0% Ø21.0

CHK_EKB15D4200/400/800/1000/1

200/2000A±4.0V 0~±4000A ±12–15 < ±1.0% Ø40.5

CHK_F15D4200/400/800/1000/1

200/2000A±4.0V 0~±3000A ±12–15 < ±1.0% 12.5*41.0

CHK_F15D4H200/400/800/1000/1

200/2000A±4.0V 0~±3000A ±12–15 < ±0.5% 12.5*41.0

CHK_FK15D4200/400/800/1000/1

200/2000A±4.0V 0~±4000A ±12–15 < ±1.0% 13.0*41.0

CHK_FK15D4H200/400/800/1000/1

200/2000A±4.0V 0~±4000A ±12–15 < ±0.5% 13.0*41.0

CHK_FK15D5H200/400/800/1000/1

200/2000A±5.0V 0~±4000A ±12–15 < ±0.5% 13.0*41.0

CHK_HAL15D450/100/200/300/400/600A

±4.0V 0~±1000A ±12–15 < ±1.0% 15.0*20.5

CHK_HAT15D4200/400/800/1000/1

200/1500A±4.0V 0~±2500A ±12–15 < ±1.0% 30.5*40.5

CHK_HAX15D4500/800/1000/1500/2000A

±4.0V 0~±5500A ±12–15 < ±1.0% 21.0*64.0

CHK_HB15D42000/3000/4000/6000/8000/10000A

±4.0V 0~±12000 ±12–15 < ±1.0%50.0*140.

0

CHK_K15D4400/600/800/1000/1

200/2000A±4.0V 0~±3000A ±12–15 < ±1.0

16.0*64.0

CHK_KA15D4600/800/1000

/2000/4000/5000A±4.0V

0~±10000A

±12–15 < ±1.0%36.0*104.

0

CHK_KB15D51000/3000/4000/5000/8000/10000A

±5.0V0~

±12000A±12–15 < ±1.0%

36.0*140.0

CHK_KC15D4500/800/1000/

1500/2000/2500A±4.0V 0~±3000A ±12–15 < ±1.0% 85.0*27.0

CHK_LB15D4 50/100/200/300A ±4.0V 0~±450A ±12–15 < ±1.0% Ø16.0

CHK_LTB15D4200/400/800/1000/1

2000/2000A±4.0V 0~±3000A ±12–15 < ±1.0% Ø35.0

CHK_LTK15D450/100/200/300/400/600A

±4.0V 0~±900A ±12–15 < ±1.0% Ø20.0

CHK_N15D450/100/200/300/400/600A

±4.0V 0~±900A ±12–15 < ±1.0% 22.0*16.0

Closed Loop Hall Current Sensor Single Power Supply

Case Type ModelNominalCurrent(RMS)

Vout/Iout@Ipn

MeasuringRange

SupplyVoltageDC

Accuracy@IPN,+25°C

Mounting(mm)

Page 8: Cheemi e catalogue for hall effect sensors

Cheemi Technology Co., Ltd

Tel: 025-85996365 E-mail: [email protected] www. cheemi-tech.com

CHB_AP3S1 50/100A 1.650±1.250V 0~±100A +3.3V < ±0.5% 10.5*16.2

CHB_AP5S50 50/100A +50mA 0~+100A +5V < ±0.5% 10.5*16.2

CHB_AP9S5050/100/125/2

00A+50/100/125

mA0~+600A +9–15V < ±0.5% 10.5*16.2

CHB_AP18S1R50/100/125/2

00A+1.0V 0~+600A +15–18V < ±0.5% 10.5*16.2

CHB_BS3S1H20/50/100/20

0A1.650±1.250V 0~±200A +3.3V < ±0.5% 10.5*20.5

CHB_BS3S6H20/50/100/20

0A1.650±0.625V 0~±200A

+3.3V< ±0.5% 10.5*20.5

CHB_DS3S606/15/25/50

A1.650±0.625V 0~±100A +3.3V < ±0.7% 4.4*6.6

CHB_DS5S106/15/25/50

A2.5±1.25V 0~±150A +5V < ±0.7% 4.4*6.6

CHB_DS5S215/20/25/30

A2.500±2.0V 0~±30A +5V < ±0.7% 4.4*6.6

CHB_DS5S606/15/25/50

A2.5±0.625V 0~±150A +5V < ±0.7% 4.4*6.6

CHB_DS5S6H06/15/25/50

A2.5±0.625V 0~±150A +5V < ±0.5% 4.4*6.6

CHB_DSR5S606/15/25/50

A2.5±0.625V 0~±150A +5V < ±0.7% 4.4*6.6

CHB_DSR5S6H06/15/25/50

A2.5±0.625V 0~±150A +5V < ±0.5% 4.4*6.6

CHB_E3S6H25/50/100/15

0A1.650±0.625V 0~±240A +3.3V < ±0.5% Ø20.5

CHB_E5S2RH06/20/50/100

A2.500±2.0V 0~±100A +5V < ±0.5% Ø20.5

CHB_E5S2050/100/150/2

00A+20~100mA 0~+200A +5V < ±0.5% Ø20.5

CHB_ES3S610/25/50/75

A1.650±0.625V 0~±150A +3.3V < ±0.7% Ø8.2

CHB_ES3S6H10/25/50/75

A1.650±0.625V 0~±150A +3.3V < ±0.5% Ø8.2

CHB_ES5S210/25/50/75

A2.500±2.0V 0~±75A +5V < ±0.7% Ø8.2

CHB_ES5S610/25/50/75

A2.500±0.625V 0~±150A +5V < ±0.7% Ø8.2

CHB_ES5S6H10/25/50/75

A2.500±0.625V 0~±150A +5V < ±0.5% Ø8.2

Page 9: Cheemi e catalogue for hall effect sensors

Cheemi Technology Co., Ltd

Tel: 025-85996365 E-mail: [email protected] www. cheemi-tech.com

CHB_LSP3S105/10/20/25

A1.650±1.250V 0~±25A +3.3V < ±0.7% Ø8.5

CHB_LSP3S1H10/15/20/40

A1.650±1.250V 0~±40A +3.3–5V < ±0.5% Ø8.5

CHB_LSP5S206/15/20/25/

30A2.500±2.0V 0~±30A +5V < ±0.7% Ø8.5

CHB_LSP5S2H10/15/20/25/

30A2.500±2.0V 0~±30A +5V < ±0.5% Ø8.5

CHB_LSP5S2R10/15/20/25/

30A2.500±2.0V 0~±30A +5V < ±0.7% Ø8.5

CHB_LSP5S10 10/20A ±10V 0~+40A +5V–12V < ±0.5% Ø8.5

CHB_LSP5S20R 10/20A ±20V 0~+20A +5V < ±0.5% Ø8.5

CHB_LSP12S10 10/20A ±10V 0~+40A +5V–12V < ±0.5% Ø8.5

CHB_LTA5S2H50/100/200/3

00A2.500±2.0V 0~±300A +5V < ±0.5% Ø20.0

CHB_LTA5S2H-S1

50/100/200/300A

2.500±2.0V 0~±300A +5V < ±0.2% Ø20.0

CHB_LTA24S2H 50/100/200A 2.500±2.0V 0~±200A +24V < ±0.2% Ø20.0

CHB_LTB5S250/60/100/20

0A2.500±2.0V 0~±200A +5V < ±0.5% Ø35.0

CHB_LTR5S225/50/75/100

A2.500±2.0V 0~±100A +5V < ±0.7% Ø20.2

CHB_LX5S605/10/15/25

A2.500±0.625V 0~±80A +5V < ±0.7% PCB

CHB_PS3S605/10/15/25

A1.650±0.625V 0~±50A +3.3V < ±0.7% PCB

CHB_PS5S605/10/15/25

A2.500±0.625V 0~±80A +5V < ±0.7% PCB

Closed Loop Hall Current Sensor Dual Power Supply

Case Type ModelNominal Current

(RMS)Vout/Iout@Ipn

MeasuringRange

SupplyVoltageDC

Accuracy@IPN,+25°C

Mounting(mm)

CHB_AP15D_

50/100/125/200A

±50/125/100mA

0~±600A ±9–15V < ±0.5% 10.5*16.2

Page 10: Cheemi e catalogue for hall effect sensors

Cheemi Technology Co., Ltd

Tel: 025-85996365 E-mail: [email protected] www. cheemi-tech.com

CHB_BA15D_

50/100/200/300/400A

±50/100mA 0~±600A ±12–18V < ±0.5% 10.5*20.5

CHB_C15D_

25/50A±12.5/

25/50//25mA0~±120A ±12–15V < ±0.5% PCB

CHB_D15D25

25/50A ±25mA 0~±100A ±12–15V < ±0.5% 4.4*6.6

CHB_E15D_

50/100/200/300/400A

±50/100mA 0~±600A ±12–18V < ±0.5% Ø20.5

CHB_EC15D50

50/75/100A ±50mA 0~±200A ±12–15V < ±0.5% Ø8.2

CHB_LA15D_

25/50/75/100A ±25/50mA 0~±150A ±12–15V < ±0.5% 7.0*12.7

CHB_LAE15D_

50/100/200/300A

±50/100/150mA

0~±700A±12–18V

< ±0.5% 13.0*30.0

CHB_LAP15D_

50/100/125/200A

±50/100/125mA

0~±600A ±9–15V < ±0.5% 10.5*16.2

CHB_LE15D50

100A ±50mA 0~100A ±12–15V < ±0.5% Ø15.0

CHB_LF15D400

2000A ±400mA 0~±3000A ±15–24V < ±0.2% Ø60.5

CHB_LF15D_

1000/1200/2000A

±200/400mA 0~±3000A±15–24V

< ±0.2% Ø60.5

CHB_LFD15D

300/600/1000A±150/120/20

0mA0~±1500A ±15–24V < ±0.2% Ø38.5

CHB_LFD24D

300/600/1000/1200A

±150/120/200/240

mA0~±2400A ±24V < ±0.2% Ø38.5

CHB_LSP15D25

25/50A ±25mA 0~±100A±12–15V

< ±0.5% Ø8.5

CHB_LTA15D_

50/100/200/300A

±50/100mA 0~±900A±12–18V

< ±0.5% Ø20.0

CHB_LTA15D3.0

30/100/200/300A

±3.0V 0~±600A±12–18V

< ±0.5% Ø20.0

CHB_LTB15D100

200/300/400/500A

±100mA 0~±1500A±15–24V

< ±0.5% Ø35.0

CHB_LTB15D4

200/300/400/500A

±4.0V 0~±1000A±15–24V

< ±0.5% Ø35.0

Page 11: Cheemi e catalogue for hall effect sensors

Cheemi Technology Co., Ltd

Tel: 025-85996365 E-mail: [email protected] www. cheemi-tech.com

CHB_LTR15D_

50/100/200/300A

±50/100mA 0~±900A±12–18V

< ±0.5% Ø20.2

CHB_LX15D4

05/10/15/20/30/50A

±4.0V 0~±150A±12–15V

< ±0.5% PCB

CHB_LXA15D20

05/10/15/20/30/50A

±20.0mA 0~±100A±12–15V

< ±0.5% PCB

CHB_SH15D200

1000A ±200mA 0~±2000A±15–24V

< ±0.2% Ø40.5

CHB_SY15D4

05/10/20/25A ±4.0V 0~±150A±12–15V

< ±0.5% PCB

CHB_SYA15D20

05/10/15/20/30/50A

±20.0mA 0~±100A±12–15V

< ±0.5% PCB

Hall Effect Voltage Sensor

Case Type ModelNominal Current

(RMS)Vout/Iout@Ipn

MeasuringRange

SupplyVoltageDC

Accuracy@IPN,+25°C

Mounting(mm)

CHV_AS3S6

05/10mA1.650±0.625

V0~±20mA +3.3V < ±0.5% PCB

CHV_AS5S6

05/10mA 2.5±0.625V 0~±20mA +5V < ±0.5% PCB

CHV_AS12S4

05/10mA +4.0V 0~+20mA +12V < ±0.5% PCB

CHV_AV5S20

200/400/600/800/1000A

+20mA 0~+1400V +5V < ±0.5% PCB

CHV_AVDA5S4

80/100/600/800/1000A

4.0+16.0mA 0~+1400V +5V < ±0.7% PCB

CHV_AVDA24S4

80/100/600/800/1000A

4.0+16.0mA 0~+1400V +24V < ±0.7% PCB

CHV_A15D25

05/10mA ±25mA 0~±14mA±12–15V

< ±0.5% PCB

CHV_AC15D25

200/400/600/800/1000A

±25mA 0~±1400V±12–15V

< ±0.5% PCB

CHV_AV15D4

200/400/600/800/1000A

±4.0V 0~±1400V±12–15V

< ±0.5% PCB

CHV_AV15D5

200/400/600/800/1000A

±5.0V 0~±1400V±12–15V

< ±0.5% PCB

CHV_T15D50

200/400/600/800/1000A

±50mA 0~±1400V±12–15V

< ±0.5% PCB

Page 12: Cheemi e catalogue for hall effect sensors

Cheemi Technology Co., Ltd

Tel: 025-85996365 E-mail: [email protected] www. cheemi-tech.com

Current Transmitter

Case Type ModelNominal Current

(RMS)Vout/Iout@Ipn

MeasuringRange

SupplyVoltageDC

Accuracy@IPN,+25°C

Mounting(mm)

CHK_BSD15D5

AC20/100/200/300/400/600A

±5.0V 0~±1200A ±12–15V < ±1.0% 10.5*20.5

CHK_BSDA24S0/4

50/100/200/300/400/600A 4.0+16.0mA

0~+1200A +12–24V < ±1.0% 10.5*20.5

CHK_EKAD24S5

50/100/200/300/400/600A

±5.0V 0~+1200A+12–24V

< ±1.0% Ø21.0

CHK_EKADA24S0/4

50/100/200/300/400/600A

4.0+16.0mA 0~+1200A +12–24V < ±1.0% Ø21.0

CHK_EKBD24S5

200/400/800/1000/1500/2000A

±5.0V 0~+4000A +12–24V < ±1.0% Ø40.5

CHK_EKBDA24S0/4

200/400/800/1000/1500/2000A

4.0+16.0mA 0~+4000A +12–24V < ±1.0% Ø40.5

CHK_HCDA24S0/4

5000/6000/10000/15000/20000A

4.0+16.0mA 0~+22000 +12–24V < ±1.0% 100.0*210.0

CHK_LTADA24S4T

10/20/50/75/100A

4.0+16.0mA 0~+300A +12–32V < ±0.5% Ø20.0

CHK_LTG24S4

05/10/20/30/50/100A

4.0+16.0mA 0~+200A +12–24V < ±1.0% Ø12.0

DC Leakage Current Transducer

Case Type ModelNominal Current

(RMS)Vout/Iout@Ipn

MeasuringRange

SupplyVoltageDC

Accuracy@IPN,+25°C

Mounting(mm)

CHD_E15D5

01/05/10/20/30/40/50/100mA

±5.0V 0~±200mA ±12–15V < ±1.0% Ø20.0

CHD_LH15D5

01/05/10/20/30/40/50/100mA

±5.0V 0~±200mA ±12–15V < ±1.0% Ø20.0

CHD-LTA15D5

01/05/10/20/30/40/50/100mA

±5.0V 0~±200mA ±12–15V < ±1.0% Ø20.0

CHD_LTB15D5

10/20/50/100mA ±5.0V 0~±200mA ±12–15V < ±1.0% Ø43.0

Page 13: Cheemi e catalogue for hall effect sensors

Cheemi Technology Co., Ltd

Tel: 025-85996365 E-mail: [email protected] www. cheemi-tech.com

Proximity Sensor SeriesHall Proximity Sensor:H-JK/JB/JZ----C Series

Introduction Principle:H-JK series hall proximity switch is a new type of

automatic switching device based on the principle of hall effect. This product adopts the round tube shaped waterproof design, Application: It reaches IEC144 standard and widely used in

light industry, chemical industry, textile, printing, machinery,metallurgy, telecommunications, transportation, automaticcontrol, computer and other fields.

It is divided into three categories according to the workingstate :JK - normally open type,JB - normally closed type,JZ - self - lock type.

Features: High response frequency, strong anti-interference

ability High precision - repeat positioning. Multi-function for protection with working status

indicator. Can be directly interface with the programming

controller (PLC). High reliability, long lifespan.

Case Type ModelSupplyVoltage(DC:V)

WorkingDistance(mm)

PositioningAccuracy(mm)

ResponseFrequency(KHz)

WorkingTemperatur

e

OutputMode

M6

JK5002C DC5-24 5-7 0.02 100 Ⅰ/Ⅱ NPN

JK8002C DC5-24 8-11 0.02 100 Ⅰ/Ⅱ NPN

M8

JK5002C DC5-24 5-7 0.02 100 Ⅰ/Ⅱ NPN/PNP

JK8002C DC5-24 8-11 0.02 100 Ⅰ/Ⅱ NPN/PNP

M10

JK5002C DC5-24 5-7 0.02 100 Ⅰ/Ⅱ NPN/PNP

JK8002C DC5-24 8-11 0.02 100 Ⅰ/Ⅱ NPN/PNP

M12

JK5002C DC5-24 5-7 0.02 100 Ⅰ/Ⅱ NPN/PNP

JK8002C DC5-24 8-11 0.02 100 Ⅰ/Ⅱ NPN/PNP

Hall Proximity Sensor:H-JK/JB/JZ----D Series

M12

JK5002D DC5-30 5-7 0.02 100 Ⅰ/Ⅱ NPN/PNP

JK8002D DC5-30 8-11 0.02 100 Ⅰ/Ⅱ NPN/PNP

JK5020D DC5-30 5-7 0.02 50 Ⅰ/Ⅱ NPN/PNP

JK8020D DC5-30 8-11 0.02 50 Ⅰ/Ⅱ NPN/PNP

Page 14: Cheemi e catalogue for hall effect sensors

Cheemi Technology Co., Ltd

Tel: 025-85996365 E-mail: [email protected] www. cheemi-tech.com

JK5050D DC5-30 5-7 0.02 50 Ⅰ/Ⅱ NPN/PNP

JK8050D DC5-30 8-11 0.02 50 Ⅰ/Ⅱ NPN/PNP

JK5100D DC5-30 5-7 0.02 50 Ⅰ/Ⅱ NPN/PNP

JK8100D DC5-30 8-11 0.02 50 Ⅰ/Ⅱ NPN/PNP

1)The supporting magnet steel adopts the S surface of Φ8×4 Ndfeb magnets(surface magnetic induction intensity is0.3T) ;other magnet is also available, but the working distance will change.2) Series of JK/JB/JZ are using three-core sheath cable with length of 50cm. If there isn’t clear requirement for the outputpolarity,please refer to the way of NPN.3) Working Temperature(℃): Ⅰ: -40~+125; Ⅱ: -25~+85;4)Both the configuration parameters and the cable length can be customized.5)Please state the full part number on the order,such as JK8002CⅡ.

Inductive Proximity Sensor: LJK/LJB Series DC Cylinder-shaped Sensor

Introduction Principle: Inductive Proximity Switches are developed based

on a coil and high frequency oscillator that creates a field inthe close surroundings of the sensing surface. The presence ofmetal in the operating area causes a change in the oscillationamplitude. This change is identified by a threshold circuit,which changes the output of the sensor.

Standard Detected Object: Inductive proximity sensors detectthe presence, movement and position of metallic objects.

The operating distance of the sensor depends on the coil’s sizeas well as the target’s shape, size and material.

It is divided into two categories according to the workingstate :JK - normal open type,JB - normal closed type

Features: Contactless detection of metal objects, to avoid

damage to the sensor itself and the target. No contact output, high reliability, stable operation

and long service life High repeatability positioning accuracy and excellent

measurement accuracy Small sensor, flexible installation.

Case Type Model Supply Detection Standard Response Working Output Mode

Page 15: Cheemi e catalogue for hall effect sensors

Cheemi Technology Co., Ltd

Tel: 025-85996365 E-mail: [email protected] www. cheemi-tech.com

Voltage (V) Distance(mm)

DetectedObject (Iron: mm)

Frequency(KHz)

Temperature

Sensors embeddedin

metal

Sensors notembedded in metal

ΦM12*60

LJK-M-D2N DC5-30 2±10% 12*12*1 1 Ⅱ NPN/PNP

LJK-M-D2P DC5-30 2±10% 12*12*1 1 Ⅱ NPN/PNP

LJK-M-D2L DC5-30 2±10% 12*12*1 1 ⅡDC

two-wire

LJK-D4N DC5-30 4±10% 15*15*1 1 Ⅱ NPN/PNP

LJK-D4P DC5-30 4±10% 15*15*1 1 Ⅱ NPN/PNP

LJK-D4L DC5-30 4±10% 15*15*1 1 ⅡDC

two-wire

Sensors embeddedin

metal

Sensors notembedded in metal

ΦM18*60

LJK-M-D4N DC5-30 4±10% 18*18*1 1 Ⅱ NPN/PNP

LJK-M-D4P DC5-30 4±10% 18*18*1 1 Ⅱ NPN/PNP

LJK-M-D4L DC5-30 4±10% 18*18*1 1 ⅡDC

two-wire

LJK-D8N DC10-30 8±10% 30*30*1 1 Ⅱ NPN/PNP

LJK-D8P DC10-30 8±10% 30*30*1 1 Ⅱ NPN/PNP

LJK-D8L DC10-30 8±10% 30*30*1 1 ⅡDC

two-wire

Sensors embeddedin

metal

Sensors notembedded in metal

ΦM30*60

LJK-M-D10N DC5-30 10±10% 30*30*1 1 Ⅲ NPN/PNP

LJK-M-D10P DC5-30 10±10% 30*30*1 1 Ⅲ NPN/PNP

LJK-M-D10L DC5-30 10±10% 30*30*1 1 ⅢDC

two-wire

LJK-D15N DC5-30 15±10% 45*45*1 1 Ⅲ NPN/PNP

LJK/-D15P DC5-30 10±10% 45*45*1 1 Ⅲ NPN/PNP

LJK-D15L DC5-30 10±10% 45*45*1 1 ⅢDC

two-wire

Structure Parameter

Page 16: Cheemi e catalogue for hall effect sensors

Cheemi Technology Co., Ltd

Tel: 025-85996365 E-mail: [email protected] www. cheemi-tech.com

Type Diagram(Unit:mm) Dimension A B C D

Sensors embeddedin metal

M12 M12×1 35 52

M18 M18×1 45 57

M30 M30×1 45 63

Sensors notembedded in metal

M12 M12×1 35 57 6

M18 M18×1 45 72 10

M30 M30×1 45 72 10

ConnectionRemarks:1)Inductive proximity sensors detect the metallic objects,

2)The detection distance may fluctuate with the different materials of the

detected target.

3)Working Temperature(℃): Ⅰ: -40~+125℃; (not frozen)

Ⅱ: -25~+85℃;(not frozen)

Ⅲ:-10℃~+70℃ (not frozen)

4)Both the configuration parameters and the cable length can be

customized. Standard cable length 1.5M.

5)If no explicit requirement for the output polarity, the proximity sensor

will be supplied based on NPN mode.

6)Please state the full part number on the order, such as LJK-M-D2NⅡ.

Case Type ModelSupplyVoltage(V)

DetectionDistance(mm)

StandardDetected

Object (Iron: mm)

ResponseFrequency(KHz)

WorkingTemperature

Output Mode

Sensors notembedded in

metalM12

LJK-A4G AC90-250 4 18*18*1 1 ⅢAC

two-wire

Sensors notembedded inmetal M18

LJK-A8G AC90-250 8 30*30*1 1 ⅢAC

two-wire

Inductive Proximity Sensor: L-JK/JB Series AC Cylinder-shaped Sensor

Page 17: Cheemi e catalogue for hall effect sensors

Cheemi Technology Co., Ltd

Tel: 025-85996365 E-mail: [email protected] www. cheemi-tech.com

Inductive Proximity Sensor: L-JK/JB Series DC Square-shaped Sensor

Case Type ModelSupply

Voltage (V)

DetectionDistance(mm)

StandardDetected

Object (Iron: mm)

ResponseFrequency(KHz)

WorkingTemperature

Output Mode

L-JK12M5N DC10-30 2/4 12*12*1 1 Ⅱ NPN/PNP

L-JK17M5N DC10-30 4/8 17*17*1 1 Ⅱ NPN/PNP

L-JK12D5L DC10-30 2/4 12*12*1 1 ⅡDC

two-wire

L-JK17D5L DC10-30 4/8 17*17*1 1 ⅡDC

two-wire

Structure parameterType Diagram(Unit:mm) Dimension A B C D

Sensors notembedded in metal

12*12*45

M12 M12×1 35 57 6

M18 M18×1 45 72 10

Connection

NPN

PNP

DC Two-wire

Remarks:1)Inductive proximity sensors detect the metallic objects,2)The detection distance may fluctuate with the differentmaterials of the detected target.6)Both the configuration parameters and the cable length can becustomized. Standard cable length 1.5M.7)If no explicit requirement for the output polarity, theproximity sensor will be supplied based on NPN mode.6 ) Please state the full part number on the order, such asLJK-A4GⅢ or L-JK12M5NⅡ.

Page 18: Cheemi e catalogue for hall effect sensors

Cheemi Technology Co., Ltd

Tel: 025-85996365 E-mail: [email protected] www. cheemi-tech.com

Magnetic Proximity Sensor/SwitchMJK/MJB/MJKB Series

Introduction Principle: Magnetic switch is also called the magnetron,

which is a switching element controlled by the magneticfield signal. Disconnect once non-magnetic.

Magnetic switches are used to detect circuit or the state ofmechanical movement and widely applied in Security Door,household doors, printers, fax machines, telephones andother electronic equipment.

Working state :MJK - Normal Open type,MJB - Normal Close type,SPDT MJKB type.

Features: Small size, light weight, easy installation Good insulation performance, suitable for all kinds

of complex environment Long life-span, high reliability and high stability. Customized service available

Case Type ModelSupplyVoltage(DC:V)

Max. PowerMax.Power

Max.SwitchingCurrent

Min.BreakdownVoltage

Max.LoadCurrent

M6

MJK/B/KB-

DC5-24V

10W DC100V 0.5A DC200V 1.0A

M8

DC5-24V

10W DC100V 0.5A DC200V 1.0A

M10

DC5-24V

10W DC100V 0.5A DC200V 1.0A

M12

DC5-24V

10W DC100V 0.5A DC200V 1.0A

M18

DC5-24V

10W DC100V 0.5A DC200V 1.0A

MJK/B/KB-23DC5-24

V10W DC100V 0.5A DC220V 1.0A

MJK/B/KB-30DC5-24

V10W DC100V 0.5A DC220V 1.0A

MJK/B/KB-48DC5-24

V10W DC100V 0.5A DC220V 1.0A

1) Series of MJK, MJB are using two-core sheath cable, MJKB series apply three-core sheath cable with length of 50cm. Ifthere isn’t clear requirement for the output polarity,please refer to the way of NPN.

Page 19: Cheemi e catalogue for hall effect sensors

Cheemi Technology Co., Ltd

Tel: 025-85996365 E-mail: [email protected] www. cheemi-tech.com

3) Working Temperature(℃):-25~+85℃;

4)Both the configuration parameters and the cable length can be customized.5)Please state the full part number on the order,such as MJK-M6.

Temperature Sensors

PT100 series RTD Temperature SensorIntroduction Principle: PT100 series thermal resistance

temperature sensor develops based on the principlethat RTD changes with temperature, and presenting acertain functional relation.

Application: Usually PT100 series RTD TemperatureSensors are matched with temperature transmitter,display instrument and computer to directly measurethe temperature of liquid, gas and solid surfaceranging from -200℃~500℃ during the productionprocess.

Features: Anti vibration, good stability, high accuracy High anti-pressure ability Graduation: PT100、PT1000 optional Explosion-proof grade: ExiaⅡCT4(intrinsic safety type)

Case TypeCaseType

Graduation

MeasuringRange(℃)

AccuracyClass

Tolerance(Δ℃)OutputMode

ThermowellMaterial

WZP

Pt20

-200~+500

1/3DIN ±(0.10+0.0017|t|)

two-wiresystem/three wiresystem

Stainless steel

A level ±(0.15+0.0002|t|)

B level ±(0.30+0.0005|t|)

2B level ±(0.60+0.0010|t|)

pt100

1/3DIN ±(0.10+0.0017|t|)

A level ±(0.15+0.002|t|)

B level ±(0.30+0.005|t|)

2B level ±(0.60+0.0010|t|)

Pt500

1/3DIN ±(0.10+0.0017|t|)

A level ±(0.15+0.002|t|)

B level ±(0.30+0.005|t|)

2B level ±(0.60+0.0010|t|)

Pt1000

1/3DIN ±(0.10+0.0017|t|)

A level ±(0.15+0.002|t|)

B level ±(0.30+0.005|t|)

2B level ±(0.60+0.0010|t|)

Page 20: Cheemi e catalogue for hall effect sensors

Cheemi Technology Co., Ltd

Tel: 025-85996365 E-mail: [email protected] www. cheemi-tech.com

Temperature TransmitterIntroduction

SBWR/Z Series Temperature Transmitter is used withIndustrial thermocouple and RTD.

It applies two-wire transmission mode (two wires as thecommon transmission line of power input and signal output )to convert thermocouple and RTD signals into output signal4~20mA.

The series products has been widely used in industrialcontrol field.

Features: Can be directly installed in the sensor terminal box Accurate signal can be transmitted far way(Max

1000M) High long-term stability, maintenance-free

Case Type Model Input SignalMeasuring

Range(℃)Tolerance

MeasuringRange(V)

Output ModeOutputLoad(Ω)

SBWZThermocoupleK E J B S T NRTD: PT20PT100 PT500

PT1000

-200~1800

0.2%FS

DC24±10% 4~20mA

250

SBWR 0.2%FS 250

Thermocouple/RTD

Introduction

Thermocouple/RTD is usually used with display instrument,recording instrument and computer to directly measure thetemperature of liquid, gas and solid surface ranging from 0℃~

1800℃ during the production process.

Features: Simple matching for easy replacement Pressure spring type temperature sensing element,

high anti-vibration performance Wide measuring range High mechanical strength, excellent pressure

resistance.

Case Type Model Input SignalMeasuringRange(℃)

Accuracy Class

Tolerance(Δ℃)OutputMode

OutputLoad(Ω)

ModelThermocoupleK E J B S T N

-200~1800

A level ±(1.5+0.004|t|)

two-wiresystem/three wiresystem

Stainless steel

B level ±(2.5+0.0075|t|)

WZPKRTD

PT20 PT100PT500 PT1000

1/3DIN ±(0.10+0.0017|t|)

A level ±(0.15+0.002|t|)

B level ±(0.30+0.005|t|)

2B level ±(0.60+0.0010|t|)

Page 21: Cheemi e catalogue for hall effect sensors

Cheemi Technology Co., Ltd

Tel: 025-85996365 E-mail: [email protected] www. cheemi-tech.com

Ultra-micro Current TransformerIntroduction: Current Transformer is also called instrument transformer, including current

transformer and voltage transformer. It is used to proportionally convert high voltage or large current into standard voltage

(100V) or standard small current (5A or 1A, rated value), to realize the miniaturizationand standardization of the measuring instrument, equipment protection and automaticcontrol equipment.

Current transformer can also be used to separate the high voltage system to ensure thesafety of the personal and equipment.

Features:● Small size● High accuracy● Good consistency.● Used for current and powermeasurement

Current Transformer

Case Type ModelRatedInputCurrent

RatedOutputCurrent

TurnsRatio

Phase AngleError

Linear RangeMounting(mm)

CMCT102 5A 2.5mA 2000:1≤20'

(1A, 100Ω)0~20A

(100Ω)Ø5.0

CMCT103C 5A 5mA 1000:1≤15'

(5A, 50Ω)0~10A(50Ω)

PCB

CEMCT131 5A 2.5mA 2000:1≤20'

(1A, 100Ω)0~20A

(100Ω)PCB

CEMCT132 5A 5mA 1000:1≤15'(5A,50Ω)

0~15A(50Ω) PCB

CMCT118F 5A 5mA 1000:1≤15'

(5A,50Ω)0~30A(50Ω)

PCB

CMCT118A 5A 2.5mA 2000:1≤15'

(5A, 50Ω)0~40A(50Ω)

PCB

CMCT116A 5A 2mA 2500:1≤20'

(1A,100Ω)0~70A

(100Ω)PCB

CMCT123A 5A 2.5mA 2000:1≤60'

(10A,50Ω)0~80A(50Ω)

PCB

CMCT134 5A 2.5mA 2000:1≤30'

(5A,50Ω)0~40A(50Ω)

PCB

CMCT350B 5A 5mA 1000:1≤30'

(10A,100Ω)0~10A(100Ω)

PCB

Page 22: Cheemi e catalogue for hall effect sensors

Cheemi Technology Co., Ltd

Tel: 025-85996365 E-mail: [email protected] www. cheemi-tech.com

PCB Mounting Current-Type Voltage Transformer

CMPT107 2mA 2mA 1000:1≤45'

(2mA,50Ω)0~1000V

0~10mA(50Ω)PCB

CMPT101B 2mA 2mA 1000:1≤20'

(2mA,100Ω)0~1000V

0~10mA(100Ω)PCB

Split Core Current Transformer

CEMCTK0160A/50HZ

1455mV 3000:1 -2%≤f≤+2%0~110A(75Ω)

PCB

CEMCTK0260A/50HZ

1455mV 3000:1 -2%≤f≤+2%0~90A(75Ω)

PCB