教教教教教教教教教教教教教教教教教 教教教教教教教教教教教教教教教教教 教教教教 教教教 教教 教教教教 教教教 教教 Chapter 6 Optical System Design and Performance 6.1 Point-to-Point Transmission Systems 6.1.1 Traditional Single-channel Syste ms 6.1.2 Amplified Single-Channel Systems 6.1.3 WDM Systems Overview 6.2 Modulation (Making the Light Carry a Signal) 6.2.1 On-Off Keying (OOK) NRZ Coding NRZI Coding RZ Coding 6.2.2 Receiving the Signal 6.2.3 Timing Recovery Phase Locked Loops (PLLs) Timing Jitter

Upload: serina-dillon

Post on 04-Jan-2016

25 views

Category:

Documents


1 download

DESCRIPTION

Chapter 6 Optical System Design and Performance. 6.1 Point-to-Point Transmission Systems 6.1.1 Traditional Single-channel Systems 6.1.2 Amplified Single-Channel Systems 6.1.3 WDM Systems Overview 6.2 Modulation (Making the Light Carry a Signal) 6.2.1 On-Off Keying (OOK) NRZ Coding - PowerPoint PPT Presentation

TRANSCRIPT

Page 1: Chapter 6  Optical System Design  and Performance

教育部顧問室光通訊系統教育改進計畫教育部顧問室光通訊系統教育改進計畫成功大學 黃振發 編撰成功大學 黃振發 編撰

Chapter 6 Optical System Design and Performance

6.1 Point-to-Point Transmission Systems6.1.1 Traditional Single-channel Systems6.1.2 Amplified Single-Channel Systems6.1.3 WDM Systems Overview

6.2 Modulation (Making the Light Carry a Signal)6.2.1 On-Off Keying (OOK)

• NRZ Coding• NRZI Coding• RZ Coding

6.2.2 Receiving the Signal6.2.3 Timing Recovery

• Phase Locked Loops (PLLs)• Timing Jitter

Page 2: Chapter 6  Optical System Design  and Performance

教育部顧問室光通訊系統教育改進計畫教育部顧問室光通訊系統教育改進計畫成功大學 黃振發 編撰成功大學 黃振發 編撰

6.2.4 Analogue Amplitude Modulation6.2.5 Frequency Shift Keying (FSK)6.2.6 Phase Shift Keying (PSK)6.2.7 Polarity Modulation (PolSK)

6.3 Transmission System Limits and Characteristics 6.4 Optical System Engineering

6.4.1 System Power Budgeting• Connector/Splice Loss Budgeting• Power Penalties

6.4.2 Reflections6.4.3 Bit Error Rates (BER)

Page 3: Chapter 6  Optical System Design  and Performance

教育部顧問室光通訊系統教育改進計畫教育部顧問室光通訊系統教育改進計畫成功大學 黃振發 編撰成功大學 黃振發 編撰

6.5 Optical Network6.6.1 Optical Networking Technologies

• SONET

• Gigabit Ethernet

• Fiber Channel

• ESCON

• FDDL

6.6.2 PON (Passive Optical Network)

Page 4: Chapter 6  Optical System Design  and Performance

教育部顧問室光通訊系統教育改進計畫教育部顧問室光通訊系統教育改進計畫成功大學 黃振發 編撰成功大學 黃振發 編撰

6.1.1 Traditional Single-channel Systems

A large number of electronic (digital) signals are combined using time division multiplexing (TDM) and presented to the optical transmission system as a single data stream.

Figure 6.1 Conventional Long Distance Fiber Transmission System.

6.1 Point-to-Point Transmission Systems

Page 5: Chapter 6  Optical System Design  and Performance

教育部顧問室光通訊系統教育改進計畫教育部顧問室光通訊系統教育改進計畫成功大學 黃振發 編撰成功大學 黃振發 編撰

This single data stream is carried in an optical channel at speeds ranging from 155 Mbps to 1.2 Gbps.

The wavelength used is almost always 1310 nm.

Every 30-50 km the signal is received at a repeater station, converted to electronic form, re-clocked and

re-transmitted.

When such a system needs to be upgraded all of the equipment in the link must be replaced. This is because the repeaters are code and speed sensitive devices.

6.1.1 Traditional Single-Channel System

Page 6: Chapter 6  Optical System Design  and Performance

教育部顧問室光通訊系統教育改進計畫教育部顧問室光通訊系統教育改進計畫成功大學 黃振發 編撰成功大學 黃振發 編撰

6.1.1.1 Repeaters What we do is extract the digital information strea

m from the old signal and then build a new signal containing the original information. This function is performed by a repeater.

As it travels along a wire, any signal (electrical or optical) is changed (distorted) by the conditions it encounters along its path. It also becomes weaker (attenuated) over distance due to energy loss.

Thus it becomes necessary to boost the signal.

6.1.1 Traditional Single-Channel System

Page 7: Chapter 6  Optical System Design  and Performance

教育部顧問室光通訊系統教育改進計畫教育部顧問室光通訊系統教育改進計畫成功大學 黃振發 編撰成功大學 黃振發 編撰

The signal can be boosted by simply amplifying it. This makes the signal stronger, but (as is shown in Figure 6.2)

it amplifies a distorted signal. A digital signal is received and it is reconstructed in the

repeater. A new signal is passed on (the 2nd example of Figure 6.2) which is completely free from any distortion that was present when the signal was received at the repeater.

Figure 6.2 Repeater Function compared with Amplification.

6.1.1 Traditional Single-Channel System

Page 8: Chapter 6  Optical System Design  and Performance

教育部顧問室光通訊系統教育改進計畫教育部顧問室光通訊系統教育改進計畫成功大學 黃振發 編撰成功大學 黃振發 編撰

6.1.2 Amplified Single-Channel Systems

Figure 6.3 Amplified Single-Channel Transmission System. The systems use optical amplifiers (EDFAs) with span lengths from 110 to 150 km.

Page 9: Chapter 6  Optical System Design  and Performance

教育部顧問室光通訊系統教育改進計畫教育部顧問室光通訊系統教育改進計畫成功大學 黃振發 編撰成功大學 黃振發 編撰

The wavelength used is now 1550nm.

This is done for two reasons:

1. To exploit the low attenuation window of fiber in the 1500 nm "window“.

2. To allow the use of Erbium Doped Fiber Amplifiers (EDFAs).

The distance between amplifiers is now increased to between 110 and 150 km.

The speed is generally increased to either 1.2 Gbps or 2.4 Gbps.

6.1.2 Amplified Single-Channel Systems

Page 10: Chapter 6  Optical System Design  and Performance

教育部顧問室光通訊系統教育改進計畫教育部顧問室光通訊系統教育改進計畫成功大學 黃振發 編撰成功大學 黃振發 編撰

There are three significant changes: (compare to Fig. 6.3)

1. In older systems, the fiber didn't disperse the signal by very much because we were using the 1310 nm band.

However, by moving to the 1550 nm band, we have brought on a dispersion problem.

2. The link may be upgraded to use higher speeds and the modulation format may be changed without changing equipment in the field. You only have to change the equipment at each end!

3. Provided the link has been planned properly it can now be upgraded to use WDM technology again without change to the outside plant.

6.1.2 Amplified Single-Channel Systems

Page 11: Chapter 6  Optical System Design  and Performance

教育部顧問室光通訊系統教育改進計畫教育部顧問室光通訊系統教育改進計畫成功大學 黃振發 編撰成功大學 黃振發 編撰

EDFAs do produce some spontaneous emission noise and this tends to get amplified along the way (it is called ASE for Amplified Spontaneous Emission).

The amplified systems are considered significantly better than the earlier systems for the following reasons:

1. Amplifiers cost less than repeaters and require less maintenance. 2. The use of an amplifier enables future upgrades and changes to take place with minimal impact (read cost) on the installed link. 3. The use of the amplifier allows for future use of WDM technology with minimal change to the outside plant.

6.1.2 Amplified Single-Channel Systems

Page 12: Chapter 6  Optical System Design  and Performance

教育部顧問室光通訊系統教育改進計畫教育部顧問室光通訊系統教育改進計畫成功大學 黃振發 編撰成功大學 黃振發 編撰

6.1.3 WDM Systems Overview

Figure 6.4 shows a typical first generation long distance WDM configuration.

Transmission is point-to-point.

Figure 6.4 WDM Long Distance Fiber Transmission System.

Page 13: Chapter 6  Optical System Design  and Performance

教育部顧問室光通訊系統教育改進計畫教育部顧問室光通訊系統教育改進計畫成功大學 黃振發 編撰成功大學 黃振發 編撰

It should be noted that each optical channel is completely independent of the other optical channels.

It may run at its own rate (speed) and use its own encodings and protocols without any dependence

on the other channels at all.

All of the current systems use a range of wavelengths between 1540 nm and 1560 nm.

There are two reasons for this: 1). to take advantage of the "low loss" transmission window in optical fiber; 2). to enable the use of erbium-dopped fiber amplifiers.

6.1.3 WDM Systems Overview

Page 14: Chapter 6  Optical System Design  and Performance

教育部顧問室光通訊系統教育改進計畫教育部顧問室光通訊系統教育改進計畫成功大學 黃振發 編撰成功大學 黃振發 編撰

6.2.1 On-Off Keying (OOK) Most current optical transmission systems enco

de the signal as a sequence of light pulses in a binary form. This is called "on-off keying" (OOK).

It is like a very simple form of digital baseband transmission in the electronic world.

The signal is there or it isn't; beyond this the amplitude of the signal doesn't matter.

6.2 Modulation (Making the Light Carry a Signal)

Page 15: Chapter 6  Optical System Design  and Performance

教育部顧問室光通訊系統教育改進計畫教育部顧問室光通訊系統教育改進計畫成功大學 黃振發 編撰成功大學 黃振發 編撰

Non-Return to Zero (NRZ) Coding

NRZ coding:

A one bit is represented as the presence of light and a zero bit is represented as the absence of light.

This method of coding is used for some very slow speed optical links but has been replaced by other methods for most purposes.

Figure 6.6. NRZ Coding

Page 16: Chapter 6  Optical System Design  and Performance

教育部顧問室光通訊系統教育改進計畫教育部顧問室光通訊系統教育改進計畫成功大學 黃振發 編撰成功大學 黃振發 編撰

NRZI Coding

In order to ensure enough transitions in the data for the receiver to operate stably, Most digital communication systems using fiber optics use Non-Return to Zero Inverted (NRZI) coding.

In NRZI coding, a zero bit is represented as a change of state on the line and a one bit as the absence of a change of state. This algorithm will obviously ensure that strings of zero bits do not cause a problem.

Figure 6.6 NRZI Encoding Example

Page 17: Chapter 6  Optical System Design  and Performance

教育部顧問室光通訊系統教育改進計畫教育部顧問室光通訊系統教育改進計畫成功大學 黃振發 編撰成功大學 黃振發 編撰

In RZ coding the signal returns to the zero state every bit time. As illustrated a "1"bit is represented by a "ON" laser state for only half a bit time. Even in the "1" state the bit is "0" for half of the time.

Figure 6.7 Return-to-Zero (RZ) Coding

Return to Zero (RZ) Coding

Page 18: Chapter 6  Optical System Design  and Performance

教育部顧問室光通訊系統教育改進計畫教育部顧問室光通訊系統教育改進計畫成功大學 黃振發 編撰成功大學 黃振發 編撰

In a restricted bandwidth environment (such as in most electronic communications) this is not a coding of choice. The reason is that there are two different line states required to represent a bit (at least for a "1" bit).

In the optical fiber environment, bandwidth is not a major constraint. RZ coding is proposed as a basis for some Optical Time-Division Multiplexing (OTDM) systems.

Return to Zero (RZ) Coding

Page 19: Chapter 6  Optical System Design  and Performance

教育部顧問室光通訊系統教育改進計畫教育部顧問室光通訊系統教育改進計畫成功大學 黃振發 編撰成功大學 黃振發 編撰

6.2.2 Receiving the Signal

1. The incoming optical signal is converted to an electronic one using either a PIN-diode or an APD.

2. The signal is then pre-amplified and passed through a band-pass filter. There are a number of very low frequencies that get into the signal and there will be very high frequency harmonics that we don't need.

Figure 6.8 Digital Receiver Functions.

Page 20: Chapter 6  Optical System Design  and Performance

教育部顧問室光通訊系統教育改進計畫教育部顧問室光通訊系統教育改進計畫成功大學 黃振發 編撰成功大學 黃振發 編撰

3. Further amplification with feedback control of the gain is used to provide stable signal levels for the rest of the process. This control circuit usually controls the bias current and thus the sensitivity of the photodiode as well.

4. A phase-locked loop is then used to recover a bit stream and (optionally) the timing information.

6. At this stage the stream of bits needs to be decoded from the coding used on the line into its data format coding. This process varies depending on the encoding and is occasionally integrated with the PLL depending on the code in use.

6.2.2 Receiving the Signal

Page 21: Chapter 6  Optical System Design  and Performance

教育部顧問室光通訊系統教育改進計畫教育部顧問室光通訊系統教育改進計畫成功大學 黃振發 編撰成功大學 黃振發 編撰

The important issues for the receiver are: Noise: In the receiver we typically have a very low level input sign

al which requires a high gain and therefore we have the potential of high noise. Most of the noise in an unamplified optical link originates in the receiver.

Decision Point: The signal level at which we say that "all voltages below this will be interpreted as a 0 and all voltages above this will be interpreted as a 1". This is a critical parameter and must be determined dynamically.

Filtering: There are both low frequency (1000 Hz or so) and very high frequency components here that are not needed. These components both add to the noise and can cause malfunction of later stages in the process. Unwanted harmonics cause the PLL to detect false conditions (called "aliases").

6.2.2 Receiving the Signal

Page 22: Chapter 6  Optical System Design  and Performance

教育部顧問室光通訊系統教育改進計畫教育部顧問室光通訊系統教育改進計畫成功大學 黃振發 編撰成功大學 黃振發 編撰

6.2.3 Timing Recovery

There are many situations where a receiver needs to recover a very precise timing from the received bit stream in addition to just reconstructing the bit stream.

In order to recover precise timing not only must there be a good coding structure with many transitions, but the receiver must use a much more sophisticated device than a DPLL to recover the timing. This device is an analogue phase locked loop.

Page 23: Chapter 6  Optical System Design  and Performance

教育部顧問室光通訊系統教育改進計畫教育部顧問室光通訊系統教育改進計畫成功大學 黃振發 編撰成功大學 黃振發 編撰

While DPLLs have a great advantage in simplicity

and cost they suffer from three major deficiencies:

1. Even at quite slow speeds they cannot recover a good enough quality clocking signal for most applications

where timing recovery is important.

2. As link speed is increased, they become less and less effective. Because circuit speeds have not increased in

the same ratio as have communication speeds.

3. As digital signals increase in speed, they start behaving more like waveforms and less like "square waves" and the simplistic DPLL technique becomes less appropriate.

Phase Locked Loops (PLLs)

Page 24: Chapter 6  Optical System Design  and Performance

教育部顧問室光通訊系統教育改進計畫教育部顧問室光通訊系統教育改進計畫成功大學 黃振發 編撰成功大學 黃振發 編撰

Figure 6.9 Operating Principle of a Continuous (Analogue) PLL

What is needed is a continuous-time, analogue PLL that is illustrated in Figure 6.9.

Phase Locked Loops (PLLs)

Page 25: Chapter 6  Optical System Design  and Performance

教育部顧問室光通訊系統教育改進計畫教育部顧問室光通訊系統教育改進計畫成功大學 黃振發 編撰成功大學 黃振發 編撰

The VCO (Voltage Controlled Oscillator) is the key to the operation. 1. The VCO is designed to produce a clock frequency close to the frequency being received. 2. Output of the VCO is fed to a comparison device (a phase detector) which matches the input signal to the VCO output. 3. The phase detector produces a voltage output which represents the difference between the input signal and the output signal. 4. The voltage output is then used to control (change) the frequency of the VCO.

Phase Locked Loops (PLLs)

Page 26: Chapter 6  Optical System Design  and Performance

教育部顧問室光通訊系統教育改進計畫教育部顧問室光通訊系統教育改進計畫成功大學 黃振發 編撰成功大學 黃振發 編撰

Properly designed, the output signal will be very close indeed to the timing and phase of the input signal.

There are two uses for the PLL output:

1. Recovering the bit stream (that is, providing the

necessary timing to determine where one bit starts

and another one ends).

2. Recovering the (average) timing (that is, providing

a stable timing source at exactly the same rate as

the timing of the input bit stream).

Phase Locked Loops (PLLs)

Page 27: Chapter 6  Optical System Design  and Performance

教育部顧問室光通訊系統教育改進計畫教育部顧問室光通訊系統教育改進計畫成功大學 黃振發 編撰成功大學 黃振發 編撰

Timing Jitter

Jitter is the generic term given to the difference between the (notional) "correct" timing of a received bit and the timing as detected by the PLL.

Some bits will be detected slightly early and others slightly late. This means that the detected timing will vary more or less randomly by a small amount either side of the correct timing - hence the name "jitter".

Jitter is minimized if both the received signal and the PLL are of high quality. But although you can minimize jitter, you can never quite get rid of it altogether.

Jitter can have many sources. In an optical system the predominant cause of jitter is dispersion.

Page 28: Chapter 6  Optical System Design  and Performance

教育部顧問室光通訊系統教育改進計畫教育部顧問室光通訊系統教育改進計畫成功大學 黃振發 編撰成功大學 黃振發 編撰

6.2.4 Analogue Amplitude Modulation (Continuous Wave)

Lasers have traditionally been very difficult to modulate using standard amplitude modulation.

This is caused by the non-linear response typical

of standard Fabry-Perot lasers.

However, some DFB and DBR lasers have a reasonably linear response and can be modulated

with an analogue waveform.

Page 29: Chapter 6  Optical System Design  and Performance

教育部顧問室光通訊系統教育改進計畫教育部顧問室光通訊系統教育改進計畫成功大學 黃振發 編撰成功大學 黃振發 編撰

The major current use of this is in cable TV and HFC distribution systems. An analogue signal is prepared exactly as though it was to be put straight onto the coaxial cable. Instead of putting it straight onto the cable it is used to modulate a laser.

At the receiver (often a simple PIN diode) the signal is amplified electronically and placed straight onto a section of coaxial cable. In standard (one-way) cable systems the maximum frequency present in the combined waveform is 500 MHz. In HFC systems this can increase up to 800 MHz or even 1 GHz.

6.2.4 Analogue Amplitude Modulation (Continuous Wave)

Page 30: Chapter 6  Optical System Design  and Performance

教育部顧問室光通訊系統教育改進計畫教育部顧問室光通訊系統教育改進計畫成功大學 黃振發 編撰成功大學 黃振發 編撰

6.2.5 Frequency Shift Keying (FSK)

It is difficult to modulate the frequency of a laser and this is one of the reasons that FM optical systems are not yet in general use. However, Distributed Bragg Reflector (DBR) lasers are becoming commercially available.

For FSK (or any system using coherent detection) to work, the real problem is the need for coherent detection.

The receiver "locks on" to the signal and is able to detect signals many times lower in amplitude than simple detectors can use. This translates to greater distances between repeaters and lower-cost systems.

In addition, FSK promises much higher data rates than the pulse systems currently in use.

Page 31: Chapter 6  Optical System Design  and Performance

教育部顧問室光通訊系統教育改進計畫教育部顧問室光通訊系統教育改進計畫成功大學 黃振發 編撰成功大學 黃振發 編撰

6.2.6 Phase Shift Keying (PSK)

You can't control the phase of a laser's output signal directly and so you can't get a laser to produce phase-modulated light.

However, a signal can be modulated in phase by placing' a modulation device in the light path between the laser and the fiber.

At this time PSK is being done in the laboratory but there are no available commercial devices.

Again, PSK requires coherent detection and this is difficult and expensive.

Page 32: Chapter 6  Optical System Design  and Performance

教育部顧問室光通訊系統教育改進計畫教育部顧問室光通訊系統教育改進計畫成功大學 黃振發 編撰成功大學 黃振發 編撰

6.2.7 Polarity Modulation (PolSK)

Lasers produce linearly polarized light. Another modulation dimension can be achieved by introducing polarization changes.

Unfortunately, this is not an available technique (not even in the lab) but feasibility studies are being undertaken to determine if PolSK could be productively used for fiber communications.

Page 33: Chapter 6  Optical System Design  and Performance

教育部顧問室光通訊系統教育改進計畫教育部顧問室光通訊系統教育改進計畫成功大學 黃振發 編撰成功大學 黃振發 編撰

6.3 Transmission System Limits and Characteristics

The characteristics of various transmission systems are summarized in Table 6.1.

Table 6.1 Optical Fiber State of the ArtMedium Source Technology Status Speed Distance Product

Copper

in use

2 Mbps 2 km 4 M

MultimodeLED

FDDI 100Mbps 2 km 200 M

SingleMode

OC-3 155 Mbps 2 km 310 M

Laser

Long Distance 10Gbps 50 km 500 G

AmplitudeModulation

in Lab

40Gbps 40 km 1.6 T

Coherent 400Mbps 370 km 150 G

Solutions 100Gbps 4000 km 8OOT

Page 34: Chapter 6  Optical System Design  and Performance

教育部顧問室光通訊系統教育改進計畫教育部顧問室光通訊系統教育改進計畫成功大學 黃振發 編撰成功大學 黃振發 編撰

A universally accepted measure of the capability of a transmission technology is the product of the maximum distance between repeaters and the speed of transmission.

In electrical systems, maximum achievable speed multiplied by the maximum distance at this speed yields a good rule of thumb constant. It is not quite so constant in optical systems, but nevertheless the speed and distance product is a useful guide to the capability of a technology.

Note that the Table 1 refers to single channel systems only.

6.3 Transmission System Limits and Characteristics

Page 35: Chapter 6  Optical System Design  and Performance

教育部顧問室光通訊系統教育改進計畫教育部顧問室光通訊系統教育改進計畫成功大學 黃振發 編撰成功大學 黃振發 編撰

Table 6.2 Signal Loss in Various Materials

Material Attenuation Regenerator Spacing

Max. 35 dB

Coaxial Cable 25 dB/km 1.5 km

Telephone Twisted Pair 12 -18 dB/km 2- 3 km

Window Glass 5 dB/km 7m

Silica - Installed 0.18 -1 dB/km 50 -150 km

Silica - Development 0.16 dB/km 250 km

Halide - Research 0.01 dB/km 3500 km

Table 6.2 shows the attenuation characteristics of various transmission media and the maximum spacing of repeaters available on that medium.

6.3 Transmission System Limits and Characteristics

Page 36: Chapter 6  Optical System Design  and Performance

教育部顧問室光通訊系統教育改進計畫教育部顧問室光通訊系統教育改進計畫成功大學 黃振發 編撰成功大學 黃振發 編撰

The concept of Table 6.2 is very conceptual. Special coaxial cable systems exist with repeater spacing of 12 km.

There exist systems capable of operating at very high speed (a few Mbps) over telephone twisted pairs for distances of four to six kilometers without repeaters.

The technology here is called ADSL (Asymmetric Digital Subscriber Line) or VDSL (Very fast Digital Subscriber Line).

This technology makes use of very sophisticated digital signal processing to eke the last bit per second from a very difficult medium. Nevertheless, the advantage of fiber transmission is obvious.

6.3 Transmission System Limits and Characteristics

Page 37: Chapter 6  Optical System Design  and Performance

教育部顧問室光通訊系統教育改進計畫教育部顧問室光通訊系統教育改進計畫成功大學 黃振發 編撰成功大學 黃振發 編撰

Attenuation of both multimode and single-mode fiber is generally linear with distance. The amount of signal loss due to cable attenuation is just the attenuation per kilometer multiplied by the distance.

To determine the maximum distance you can send a signal (leaving out the effects of dispersion), all you need to do is to add up all the sources of attenuation along the way and then compare it with the "link budget".

The link budget is the difference between the transmitter power and the sensitivity of the receiver.

6.4.1 System Power Budgeting

6.4 Optical System Engineering

Page 38: Chapter 6  Optical System Design  and Performance

教育部顧問室光通訊系統教育改進計畫教育部顧問室光通訊系統教育改進計畫成功大學 黃振發 編撰成功大學 黃振發 編撰

Thus, if you have a transmitter of power -10 dBm and a receiver that requires a signal of power -20 dBm (minimum) then you have 10 dB of link budget :

1. 10 connectors at 0.3 dB per connector = 3 dB 2. 2 km of cable at 2 dB/km (Multimode Graded index fiber at 1300 nm) = 4 dB 3. Contingency of (say) 2 dB for deterioration due to ageing over the life of the system.

This leaves us with a total of 9 dB system loss. This is within our link budget and so we would expect such a system to have sufficient power.

6.4.1 System Power Budgeting

Page 39: Chapter 6  Optical System Design  and Performance

教育部顧問室光通訊系統教育改進計畫教育部顧問室光通訊系統教育改進計畫成功大學 黃振發 編撰成功大學 黃振發 編撰

Figure 6.10 shows the characteristics of some typical devices versus the transmission speed (in bits/second).

6.4.1 System Power Budgeting

Page 40: Chapter 6  Optical System Design  and Performance

教育部顧問室光通訊系統教育改進計畫教育部顧問室光通訊系統教育改進計畫成功大學 黃振發 編撰成功大學 黃振發 編撰

1. Every laser has a limit to the maximum speed at which it can be modulated but up to that limit power output is relatively constant.

2. LEDs produce less and less output as the modulation rate is increased. The difference in fiber types only relates to the amount of power you can couple from an LED into the different types of fiber.

3. All receivers require higher power as the speed is increased. To reliably detect a bit a receiver needs a certain number of photons. Therefore every time we double the modulation speed we need to also double the required power for a constant signal-to-noise ratio.

6.4.1 System Power Budgeting

Page 41: Chapter 6  Optical System Design  and Performance

教育部顧問室光通訊系統教育改進計畫教育部顧問室光通訊系統教育改進計畫成功大學 黃振發 編撰成功大學 黃振發 編撰

If you look in the figure for a given bit rate (vertical line) there will be a difference between the required receiver power and the available transmitter power.

This difference is the amount we have available for losses in the fiber and connectors (and other optical devices such as splitters and circulators).

It is also very important to allow some margin in the design for ageing of components (lasers produce less power as they age, detectors become less sensitive, etc.).

6.4.1 System Power Budgeting

Page 42: Chapter 6  Optical System Design  and Performance

教育部顧問室光通訊系統教育改進計畫教育部顧問室光通訊系統教育改進計畫成功大學 黃振發 編撰成功大學 黃振發 編撰

Connector/Splice Loss Budgeting

The signal loss experienced at a connector or splice is not a fixed or predictable amount! The problem is the measured losses in actual splices and actual connectors vary considerably from each other.

The good news is that actual measurements form (roughly) a "normal" statistical distribution about

the mean (average).

Table 6.3 shows "typical" losses that may be expected from different connector types.

Page 43: Chapter 6  Optical System Design  and Performance

教育部顧問室光通訊系統教育改進計畫教育部顧問室光通訊系統教育改進計畫成功大學 黃振發 編撰成功大學 黃振發 編撰

Table 6.3 Connector CharacteristicsConnector Type Insertion Loss

(MM) Typical

Insertion Loss (SM) Typical

Return Loss Typical

ST 0.25 dB 0.2 dB 40 dB

SC 0.25 dB 0.2 dB 40 dB

SMA 1.5 dB

FSD 0.6 dB

FC 0.25 dB 0.2 dB 40 dB

D4 0.25 dB 0.2 dB 35 dB

DIN 0.25 dB 0.2 dB 40 dB

Biconic 0.6dB 0.3 dB 30 dB

Connector/Splice Loss Budgeting

Page 44: Chapter 6  Optical System Design  and Performance

教育部顧問室光通訊系統教育改進計畫教育部顧問室光通訊系統教育改進計畫成功大學 黃振發 編撰成功大學 黃振發 編撰

1. For a connection using almost any modern single-mode connector where both connectors are from the same supplier you can expect a mean loss of 0.2 dB with a standard deviation of 0.15 dB.

2. If the manufacturers of the two connectors are different, then you can expect an average loss of 0.35 dB with a standard deviation of 0.25 dB.

3. One type of single-mode connector may have an "average loss" of 0.2 dB but in practical situations this loss might vary from perhaps 0.1 dB to 0.8 dB.

Connector/Splice Loss Budgeting

Page 45: Chapter 6  Optical System Design  and Performance

教育部顧問室光通訊系統教育改進計畫教育部顧問室光通訊系統教育改進計畫成功大學 黃振發 編撰成功大學 黃振發 編撰

If you know the average loss for a single connector and the standard deviation () of the connector loss for a particular situation then you can calculate these figures for any given combination.

1. The average (mean) of the total is just the average loss of a single connector multiplied by the number of connectors.

2. The standard deviation () of the total is just the standard deviation of a single connector multiplied by the square root of the number of connectors involved.

Connector/Splice Loss Budgeting

Page 46: Chapter 6  Optical System Design  and Performance

教育部顧問室光通訊系統教育改進計畫教育部顧問室光通訊系統教育改進計畫成功大學 黃振發 編撰成功大學 黃振發 編撰

In long distance links it is common to regard splices as part of the fiber loss. So you might get raw SM fiber with a loss (at 1550 nm) of 0.21 dB/km. After cabling, this will increase to perhaps 0.23 dB/km.

For loss budget purposes you might allocate .26 dB/km for installed cable. Cable is typically supplied in 2 km lengths so in a100 km link there will be a minimum of 50 splices.

In the 1310 nm band, a typical cable attenuation might be 0.36 dB/km but it is typical to allocate 0.4 dB/km for fiber losses in new fiber used in this wavelength band.

The same piece of installed fiber cable would be budgeted at 0.4 dB/km when used in the 1310 nm band and at 0.26 dB/km when used in the 1550 nm band.

Connector/Splice Loss Budgeting

Page 47: Chapter 6  Optical System Design  and Performance

教育部顧問室光通訊系統教育改進計畫教育部顧問室光通訊系統教育改進計畫成功大學 黃振發 編撰成功大學 黃振發 編撰

Power Penalties

There are a number of phenomena that occur within an optical transmission system that can be compensated for by increasing the power budget.

In each case the amount of additional power required to overcome the problem is termed the "power penalty".

The three most important issues here for digital systems are :

1. System noise 2. Effect of dispersion and 3. Extinction ratio

Page 48: Chapter 6  Optical System Design  and Performance

教育部顧問室光通訊系統教育改進計畫教育部顧問室光通訊系統教育改進計畫成功大學 黃振發 編撰成功大學 黃振發 編撰

Signal-to-Noise Ratio (SNR)

The quality of any received signal in any communication system is largely determined by the ratio of the signal power to the noise power - the SNR.

In simple systems most of the noise comes from within the receiver itself and so is usually compensated for by an adjustment of the receiver sensitivity specification.

In complex systems with EDFAs, ASE noise becomes important and to compensate we indulge in power level planning throughout the system.

Power Penalties

Page 49: Chapter 6  Optical System Design  and Performance

教育部顧問室光通訊系統教育改進計畫教育部顧問室光通訊系統教育改進計畫成功大學 黃振發 編撰成功大學 黃振發 編撰

Inter-Symbol Interference (ISI)

Dispersion causes bits (really line states or bauds) to merge into one another on the link.

We can compensate for this by increasing the signal power level.

Thus for certain levels of dispersion we can nominate a system power budget (allowance) to compensate.

Power Penalties

Page 50: Chapter 6  Optical System Design  and Performance

教育部顧問室光通訊系統教育改進計畫教育部顧問室光通訊系統教育改進計畫成功大學 黃振發 編撰成功大學 黃振發 編撰

Extinction Ratio If a zero bit is represented by a finite power level rather than a

true complete absence of power then the difference between the power level of a 1-bit and that of a 0-bit is narrowed.

The power level of the 0-bit becomes the noise floor of every 1-bit. The receiver decision point has to be higher and therefore there is an increased probability of error.

This can be compensated for by an increase in available power level at the receiver. An extinction ratio of 10 dB incurs a power penalty (in either a PIN-diode receiver or an APD) of about 1 dB over what it would have been with a truly zero value for a 0-bit.

An extinction ratio of 3 dB causes a power penalty of 5 dB in a PIN-diode receiver and 7 dB in an APD.

Power Penalties

Page 51: Chapter 6  Optical System Design  and Performance

教育部顧問室光通訊系統教育改進計畫教育部顧問室光通訊系統教育改進計畫成功大學 黃振發 編撰成功大學 黃振發 編撰

6.4.2 Reflections

The reflections discussed here are unintended ones that occur at connectors, joins and in some devices.

The unwanted reflections can have many highly undesirable effects. Among the most important of these are:

1. Disruption of laser operation

2. Return Loss

3. Amplifier operation

Page 52: Chapter 6  Optical System Design  and Performance

教育部顧問室光通訊系統教育改進計畫教育部顧問室光通訊系統教育改進計畫成功大學 黃振發 編撰成功大學 黃振發 編撰

1. Disruption of laser operation : Reflections entering a laser disturb its stable operation adding no

ise and shifting the wavelength.

2. Return Loss : Reflections can vary with the signal and produce a random loss

of signal power. This is termed “ return loss ”.

3. Amplifier operation : Reflections returning into an optical amplifier can have two mai

n effects:

- In the extreme case of reflections at both ends the amplifier

becomes a laser and produces significant power of its own.

- In lesser cases reflections can cause the amplifier to saturate

(by taking away power) and again introduce noise to the signal.

6.4.2 Reflections

Page 53: Chapter 6  Optical System Design  and Performance

教育部顧問室光通訊系統教育改進計畫教育部顧問室光通訊系統教育改進計畫成功大學 黃振發 編撰成功大學 黃振發 編撰

The major causes of reflections are:

1. Joins between high RI material and fiber (such as at

the junction between a laser or LED and a fiber or

between any planar optical component and a fiber).

2. Joins between fibers of different characteristics.

For example where a Pr-doped amplifier employing

ZBLAN host glass is coupled to standard fiber for

input and output.

3. Any bad connector produces significant reflections.

4. Some optical devices such as Fabry-Perot filters

reflect unwanted light as part of their design.

6.4.2 Reflections

Page 54: Chapter 6  Optical System Design  and Performance

教育部顧問室光通訊系統教育改進計畫教育部顧問室光通訊系統教育改進計畫成功大學 黃振發 編撰成功大學 黃振發 編撰

Reflections can be controlled by the following measures: 1. Taking care with fiber connectors and joins to ensure that they are made correctly and produce minimum reflections. This can be checked using an OTDR.

2. The inclusion of isolators in the packaging of particularly sensitive optical components (such as DFB lasers and amplifiers). The isolators attenuate the signal and are polarization sensitive. Their use should be carefully planned and minimized.

3. In critical situations a diagonal splice in the fiber or a connector using a diagonal fiber interface can be employed. The diagonal join ensures that any unwanted reflections

are directed out of the fiber core.

6.4.2 Reflections

Page 55: Chapter 6  Optical System Design  and Performance

教育部顧問室光通訊系統教育改進計畫教育部顧問室光通訊系統教育改進計畫成功大學 黃振發 編撰成功大學 黃振發 編撰

On many public network optical networks today error rates of 10-14 are consistently achieved and so user expectation is that errors will be very rare events indeed.

Public network operators seem to consider the minimum acceptable error rate to be around 10-12.

The faster the link the lower we need the error rate to be! But the harder that low error rate becomes to deliver.

In many standards (such as the ATM recommendations) the expected error rate performance of links over which the system will be run are specified in the standard.

6.4.2 Reflections

Page 56: Chapter 6  Optical System Design  and Performance

教育部顧問室光通訊系統教育改進計畫教育部顧問室光通訊系統教育改進計畫成功大學 黃振發 編撰成功大學 黃振發 編撰

There are five technologies to implement the high-speed capabilities of optical networks.

For each of the five, one or more specific protocol layers have been defined by appropriate standards bodies, usually the Institute of Electrical and Electronics Engineers (IEEE) or the International Telecommunications Union (ITU).

These technologies comprise SONET, Gigabit Ethernet, Fiber Channel, IBM’s Enterprise System Connection (ESCON), and Fiber Distributed Data Interface (FDDI).

6.6.1 Optical Network Technologies

Page 57: Chapter 6  Optical System Design  and Performance

教育部顧問室光通訊系統教育改進計畫教育部顧問室光通訊系統教育改進計畫成功大學 黃振發 編撰成功大學 黃振發 編撰

SONET

SONET was the first widely deployed optical network technology. It is an electronic network technology that utilizes optical links.

It is optimized to guarantee extremely reliable transport of constant bit rate 64 kbps channels or combinations of them, either between two points, or in a ring configuration.

Because of its worldwide standards, the ready availability of equipment, and its long track record, SONET is the “gold standard” for connecting devices such as routers.

Page 58: Chapter 6  Optical System Design  and Performance

教育部顧問室光通訊系統教育改進計畫教育部顧問室光通訊系統教育改進計畫成功大學 黃振發 編撰成功大學 黃振發 編撰

Gigabit Ethernet

Gigabit Ethernet is currently the fastest implementation of the Ethernet technology.

It requires opto-electronic conversions, but does allow Local Area Networks (LANs) to take advantage of the high speed and low cost of optical components.

Gigabit Ethernet utilizes single-mode fiber and a wavelength of 1310 nm for distances up to 2 km, and multi-mode fiber at 850 nm for distances up to 200 m.

Page 59: Chapter 6  Optical System Design  and Performance

教育部顧問室光通訊系統教育改進計畫教育部顧問室光通訊系統教育改進計畫成功大學 黃振發 編撰成功大學 黃振發 編撰

Fiber Channel

Fiber Channel is an application of optical fiber for interconnection of computers and peripheral devices at relatively low speeds (i.e., low compared to possible speeds on optical networks) using standardized components.

It employs lasers or LEDs on single or multi-mode fiber, and can achieve data rates of up to 100 Mbps, over distances of up to 10 km. However, the multi-mode fiber media can only reach up to about 2 km.

Page 60: Chapter 6  Optical System Design  and Performance

教育部顧問室光通訊系統教育改進計畫教育部顧問室光通訊系統教育改進計畫成功大學 黃振發 編撰成功大學 黃振發 編撰

ESCON

ESCON is an architecture intended for connecting processors and peripherals .

It is an electro-optical system, which uses optical fiber to connect “stations” (computers or peripherals) to others through an electronic space-division switch.

Maximum data rate (as a communications device) is 160 Mbps over single-mode fiber.

Page 61: Chapter 6  Optical System Design  and Performance

教育部顧問室光通訊系統教育改進計畫教育部顧問室光通訊系統教育改進計畫成功大學 黃振發 編撰成功大學 黃振發 編撰

FDDI

FDDI was originally proposed as a standard for input/output (I/O) channels using optical fiber, but is now more commonly considered as a token-ring LAN technology that utilizes two counter-circulating rings for increased reliability.

The ring may be up to 200 km in total length, though stations can only be 2 km apart. A maximum of 500 stations is supported. Current standards allow a maximum data rate of 100 Mbps.

Multi-mode fiber is more commonly employed than single-mode fiber, though in practice, FDDI more often runs over copper wires.

Page 62: Chapter 6  Optical System Design  and Performance

教育部顧問室光通訊系統教育改進計畫教育部顧問室光通訊系統教育改進計畫成功大學 黃振發 編撰成功大學 黃振發 編撰

Table 6.4 Optical Network Technologies and Major Applications

TelecomProvider

CoreNetwork

InternetCore

ISPCorporate

MANUndersea

CablesLargeLAN

LocalDistribution

SmallOr

HomeLAN

Local or

InternalComm

WDM

OTDM

SONET

GigabitEthernet With OpticalMedium

FiberChannel

ESCON

FDDI

6.6.1 Optical Network Technologies

Page 63: Chapter 6  Optical System Design  and Performance

教育部顧問室光通訊系統教育改進計畫教育部顧問室光通訊系統教育改進計畫成功大學 黃振發 編撰成功大學 黃振發 編撰

6.6.2 PON (Passive Optical Network)

A PON network system is used for delivering broadband network access service to business and residential customers.

PON is an FTTx technology, which opens up the ‘last mile bottleneck’ present in data services available to the majority of home and business computer users today.

FTTx : Fiber-to-the-x Any network which extends fiber optic capacity

directly to the user; x can be replaced with “home”, “business”, “curb”, “cabinet”, depending on how close the fiber connection actually is to the end user. A PON network is called passive, because from the public

network connection (Central Office), to the end user, there are no active electronics required.

Page 64: Chapter 6  Optical System Design  and Performance

教育部顧問室光通訊系統教育改進計畫教育部顧問室光通訊系統教育改進計畫成功大學 黃振發 編撰成功大學 黃振發 編撰

In Fig. 6.11, PON is a network that looks like a star, where the center of the star is the service provider’s central office, and fibers reach out from the C.O. (Central Office) to all the available subscribers.

As the fiber gets closer to the end-subscriber, the fiber is split and divided among many end-points.

The fiber split is handled by a passive fiber optic component, a passive optical splitter, and one fiber is sent from the splitter point to each subscriber.

6.6.2 PON (Passive Optical Network)

Page 65: Chapter 6  Optical System Design  and Performance

教育部顧問室光通訊系統教育改進計畫教育部顧問室光通訊系統教育改進計畫成功大學 黃振發 編撰成功大學 黃振發 編撰

Fig. 6.11 PON network Diagram.

6.6.2 PON (Passive Optical Network)

Page 66: Chapter 6  Optical System Design  and Performance

教育部顧問室光通訊系統教育改進計畫教育部顧問室光通訊系統教育改進計畫成功大學 黃振發 編撰成功大學 黃振發 編撰

Signals flowing from the subscriber back to the C.O. are merged onto the same fiber, using the optical splitter in reverse.

Signals from each subscriber are processed by the C.O. receiver in sequence, using timing method called Time Domain Multiple Access.

The distance that a PON can reach is just over 12 miles.

And some description information of each element is shown in Table 6.6.

6.6.2 PON (Passive Optical Network)

Page 67: Chapter 6  Optical System Design  and Performance

教育部顧問室光通訊系統教育改進計畫教育部顧問室光通訊系統教育改進計畫成功大學 黃振發 編撰成功大學 黃振發 編撰

Table 6.5 A PON network elements description

6.6.2 PON (Passive Optical Network)

Page 68: Chapter 6  Optical System Design  and Performance

教育部顧問室光通訊系統教育改進計畫教育部顧問室光通訊系統教育改進計畫成功大學 黃振發 編撰成功大學 黃振發 編撰

A PON network reduce the cost of broadband service, primarily by:

1. sharing the cost of optical terminal equipment

(the electrical-to-optical conversion) in the

Central Office,

2. reducing the cost of servicing active devices

located in the field, and

3. sharing the fiber with multiple subscribers.

6.6.2 PON (Passive Optical Network)

Page 69: Chapter 6  Optical System Design  and Performance

教育部顧問室光通訊系統教育改進計畫教育部顧問室光通訊系統教育改進計畫成功大學 黃振發 編撰成功大學 黃振發 編撰

There are three types of PON equipment available, ATM-PON (APON), Ethernet-PON (EPON), and Gigabit PON (GPON).

APON has a means for connecting multiple subscribers to the same receiver in the Central Office, Time Domain Multiplexed Access.

This means that each subscriber transmitter talks to the C.O. receiver in turn, and the scheduling of this is controlled by the OLT line card in the C.O.

6.6.2 PON (Passive Optical Network)

Page 70: Chapter 6  Optical System Design  and Performance

教育部顧問室光通訊系統教育改進計畫教育部顧問室光通訊系統教育改進計畫成功大學 黃振發 編撰成功大學 黃振發 編撰

ATM-PON and Gigabit-PON use ATM-switching protocols to optimize real-time delivery of information, like carrying on a conversation.

ATM network conversations frequently focus on Quality of Service (QoS) as it’s best feature, which is the guarantee that every subscriber connected to the network received a certain minimum block of information to transmit its information. This is why ATM is best suited for handling voice conversations.

GPON operates similar to APON, but at higher (1.25 ~ 2.5 Gbps) line-rates.

6.6.2 PON (Passive Optical Network)

Page 71: Chapter 6  Optical System Design  and Performance

教育部顧問室光通訊系統教育改進計畫教育部顧問室光通訊系統教育改進計畫成功大學 黃振發 編撰成功大學 黃振發 編撰

EPON is designed to optimize the transmission of packets of data information.

EPON uses the same means of merging each subscriber’s upstream data onto the same fiber,

Time Domain Multiplexed Access (TDMA).

The EPON protocol uses Ethernet transmission, the data networking standard. As such, EPON can handle traffic better which is more often data- than is voice-related.

6.6.2 PON (Passive Optical Network)

Page 72: Chapter 6  Optical System Design  and Performance

教育部顧問室光通訊系統教育改進計畫教育部顧問室光通訊系統教育改進計畫成功大學 黃振發 編撰成功大學 黃振發 編撰

EPON uses Voice over IP (VoIP) to carry phone conversations, and treats all information equally, as data.

A current characteristic of VoIP is the effect that it has on what could be called “digitizing” the sound of someone’s voice.

The common argument between the APON and EPON network focuses on each standard’s strength, and which is better for a service provider to concentrate on, voice quality, or data efficiency.

6.6.2 PON (Passive Optical Network)