 ® D S E CONTROL ® MONITORING WITH INTELLIGENCE. Th e DSE73 10 an d DSE73 20 ar e new cont rol modu les for sing le gen- set appl icat ion s. The mod ules ha ve bee n de vel ope d fr om the succ essful DSE5 310 and DSE5 320 Seri es and inco rpor ate a number of advan cedfeatu re s to mee t th e mos t dema ndin g on-s ite applications. Th e DSE73 10 is an Au tomatic St art Contr ol Modul e an d theDSE7 320is an Auto Main s (Uti lity ) Fail ure Con tro l Module. Bothmodules ha ve bee n designedto start an d stop dies el and gas gen erat ing sets that incl ude elec tro nic and non-elec tronic engines. The DSE 7320 incl udes the add itio nal ca pab ili ty of being able to mon ito r a mai ns (uti lity ) supp ly . Both modu les incl ude USB , RS23 2 an d RS 48 5 po rt s as we ll as ded icat ed DSE Net® terminal s for expansio n device connecti vity. Th e modul es ar e simpl e to ope rate an d fea ture a new ly designed men u layo ut for imp rov ed clar ity . Enha nced feat ure s incl ude a rea l time clo ck forenhanced ev ent an d performance monitori ng, ethernet communi cati ons for low cost mon itor ing , mutu al stan dby to red uce engi ne wear and tear , tre nd an aly sis to as sis t in thedetec tio n of pa tte rns in engin e sta tus and prevent ative mainten ance des ign ed to de tec t if eng in e par ts have deve lope d fau lt con diti ons so the y ca n be re pl ace d be for e a majo r pro blemoccu rs. FEATURES  Backed up real time clock  132 x 64 pixel LCD display  Configurable display languages  Event logging (50), showing date and time  USB connectivity  Robust module enclosure  Five-key menu navigation  Durable soft touch membrane buttons  Fully configurable via PC software LED and LCD alarm indicatio n  Engine exercise mode  Configurable start & fuel outputs  kWh monitoring  Automatic load transfer  Six configurable digital inputs  Configurable outputs  Configurable timers and alarms  Modbus RTU  Magnetic pick-up  Front panel programming Multiple date and time exercise scheduler  SMS messaging  Power save mode  PIN protected programming  User selectable RS232 & RS485 communications  DSENet ® compatible  Ethernet communications*  Customer logo display capability*  Multiple date and time maintenance scheduler*  Configurable display pages*  Programmable load shedding/acceptance*  Trend analysis*  Mutual standby*  Preventative maintenance*  kW overload protection*  Unbalanced load protection*  PDA compatible PC software*  Configuration file downloads from an external memory device* BENEFITS  132 x 64 pixel ratio makes information easy to read  Real time clock provides accurate event logging  PC software is license fr ee  Set maintenance periods can be configured to maintain optimum engine performance  Ethernet communications provides advanced remote monitoring at low cost  Modules can be integrated into building management systems  Preventative maintenance avoids expensive engine down time  Advanced PCB layout ensures high reliability  Robust design  Extensive performance monitoring DS E7 31 0 & DS E7 32 0  AU TO ST AR T & AUTO MA INS F AI LURE CONT ROL MO DULE S (COMMU NI CA TI ON S & EX P AN SI ON) *Future enhancements SPECIFICATION DC SUPPL Y  AL TER NA TORINPU T MAINS/UTIL ITY INPUT (DSE7320ONL Y) CONTINUOUSVOLT AGE RATING 8V to 35V Continuous CRANKING DIP PROTECTION  Able to s urviv e 0V for 50 mS, pr ovidi ng supp ly was at least 10V before dropout and supply recovers to 5V. This is achieved without the need for internal batteries CHARGE FAIL/ EXCITATION 0V to 35V fixed power source 2.5W MAXIMUM STANDBY CURRENT 160mA at 12V 80mA at 24V MAXIMUM OPERATING CURRENT 340mA at 12V 160mA at 24V RANGE 15V - 333V (L-N) 50Hz - 60Hz (Minimum 15V AC Ph-N)  ACCUR ACY 1% of full scale true RMS sensing SUPPORTEDTOPOLOGIES 3 phase 4 wire 3 phase 3 wire Single phase 2 wire 2 phase 3 wire L1 & L2 2 phase 3 wire L1 & L3 RANGE 15V - 333V (L-N) 50Hz - 60Hz (Minimum 15V AC Ph-N)  ACCUR ACY 1% of full scale true RMS sensing SUPPORTEDTOPOLOGIES 3 phase 4 wire 3 phase 3 wire Single phase 2 wire 2 phase 3 wire L1 & L2 2 phase 3 wire L1 & L3 CT’S BURDEN 0.5VA PRIMARYRATING 1A - 8000A (user selectable) SECONDAR Y RATI NG 1A or 5A secondary (user selectable)  ACCUR ACY OFMEASUREM ENT 1% of full load rating RECOMMENDATIONS Class 1 required for instrumentation Protection class required if using for protection Continued on page 2 ELECTRON IC ENGINE CAP ABILITY DSE 7310-20 US v2:Layout 1 13/6/08 10:19 Page 2

Upload: jg1711

Post on 06-Oct-2015

86 views

Category:

Documents


0 download

DESCRIPTION

Modulo de control DSE 7310

TRANSCRIPT

  • DSECONTROLMONITORINGWITHINTELLIGENCE.

    The DSE7310 and DSE7320 arenew control modules for singlegen-set applications. The moduleshave been developed from thesuccessful DSE5310 and DSE5320Series and incorporate a numberof advanced features to meet themost demanding on-siteapplications.

    The DSE7310 is an Automatic StartControl Module and the DSE7320 isan Auto Mains (Utility) FailureControl Module. Both moduleshave been designed to start andstop diesel and gas generatingsets that include electronic andnon-electronic engines. TheDSE7320 includes the additionalcapability of being able to monitora mains (utility) supply.

    Both modules include USB, RS232and RS485 ports as well asdedicated DSENet terminals forexpansion device connectivity.

    The modules are simple to operateand feature a newly designedmenu layout for improved clarity.Enhanced features include a realtime clock for enhanced event andperformance monitoring, ethernetcommunications for low costmonitoring, mutual standby toreduce engine wear and tear, trendanalysis to assist in the detectionof patterns in engine status and

    preventative maintenancedesigned to detect if engine partshave developed fault conditions sothey can be replaced before amajor problem occurs.

    FEATURES Backed up real time clock 132 x 64 pixel LCD display Configurable display languages Event logging (50), showing date

    and time USB connectivity Robust module enclosure Five-key menu navigation Durable soft touch membrane

    buttons Fully configurable via PC software LED and LCD alarm indication Engine exercise mode Configurable start & fuel outputs kWh monitoring Automatic load transfer Six configurable digital inputs Configurable outputs Configurable timers and alarms Modbus RTU Magnetic pick-up Front panel programming Multiple date and time exercise

    scheduler SMS messaging Power save mode PIN protected programming User selectable RS232 & RS485

    communications DSENet compatible Ethernet communications* Customer logo display capability* Multiple date and time

    maintenance scheduler*

    Configurable display pages* Programmable load

    shedding/acceptance* Trend analysis* Mutual standby* Preventative maintenance* kW overload protection* Unbalanced load protection* PDA compatible PC software* Configuration file downloads from

    an external memory device*BENEFITS 132 x 64 pixel ratio makes

    information easy to read Real time clock provides accurate

    event logging PC software is license free Set maintenance periods can be

    configured to maintain optimumengine performance

    Ethernet communications providesadvanced remote monitoring atlow cost

    Modules can be integrated intobuilding management systems

    Preventative maintenance avoidsexpensive engine down time

    Advanced PCB layout ensureshigh reliability

    Robust design Extensive performance monitoring

    DSE7310 &DSE7320AUTOSTART & AUTOMAINS FAILURECONTROLMODULES (COMMUNICATIONS & EXPANSION)

    *Future enhancements

    SPECIFICATION

    DCSUPPLY

    ALTERNATOR INPUT

    MAINS/UTILITY INPUT (DSE7320 ONLY)

    CONTINUOUS VOLTAGERATING8V to 35V Continuous

    CRANKING DIP PROTECTIONAble to survive 0V for 50mS, providing supplywas at least 10V before dropout and supplyrecovers to 5V. This is achieved without the needfor internal batteries

    CHARGE FAIL/ EXCITATION0V to 35V fixed power source 2.5W

    MAXIMUM STANDBY CURRENT160mA at 12V 80mA at 24V

    MAXIMUM OPERATING CURRENT340mA at 12V 160mA at 24V

    RANGE15V - 333V (L-N) 50Hz - 60Hz(Minimum 15V AC Ph-N)

    ACCURACY1% of full scale true RMS sensing

    SUPPORTED TOPOLOGIES3 phase 4 wire3 phase 3 wireSingle phase 2 wire2 phase 3 wire L1 & L22 phase 3 wire L1 & L3

    RANGE15V - 333V (L-N) 50Hz - 60Hz(Minimum 15V AC Ph-N)

    ACCURACY1% of full scale true RMS sensing

    SUPPORTED TOPOLOGIES3 phase 4 wire3 phase 3 wireSingle phase 2 wire2 phase 3 wire L1 & L22 phase 3 wire L1 & L3

    CTS

    BURDEN0.5VA

    PRIMARY RATING1A - 8000A (user selectable)

    SECONDARY RATING1A or 5A secondary (user selectable)

    ACCURACYOFMEASUREMENT1% of full load rating

    RECOMMENDATIONSClass 1 required for instrumentationProtection class required if using for protection

    Continued on page 2ELECTRONICENGINECAPABILITY

    DSE 7310-20 US v2:Layout 1 13/6/08 10:19 Page 2

  • OPERATIONThe modules are operated via the START, STOP, AUTO and MANUAL softtouch membrane buttons on the front panel. The DSE7320 also has a TESTbutton. Both modules include load switch buttons. The main menu system isaccessed using the five navigation buttons to the left of the LCD display.

    CONFIGURATIONThe modules can be configured using the front panel buttons or by using thePC software and a USB lead.

    COMMUNICATIONSThe DSE7310 & DSE7320 have a number of different communicationcapabilities.

    SMSMessagingWhen the module detects an alarm condition, it has the ability to send an SMSmessage to a dedicated mobile number (s), notifying an engineer of the exacttime, date and reason why the engine failed (GSM Modem and SIM Cardrequired).

    Remote CommunicationsWhen the module detects an alarm condition, it dials out to a PC notifying theuser of the problem (Modem required).

    Remote ControlThe module can be controlled remotely using either a GSM Modem, LANModem or via RS485. Using a modem allows the module to be controlledfrom any distance. Using RS485 limits the distance to 1km (0.6 miles).

    BuildingManagementThe module has been designed to be integrated into new and existing buildingmanagement systems, using RS485.

    PC SoftwareThe module has the ability to be configured and monitored from a remote PC,using the PC software and a USB lead.

    INPUTS &OUTPUTSAnalogue inputs are provided for oil pressure, coolant temperature and fuellevel. These connect to conventional engine mounted resistive sender units toprovide accurate monitoring and protection facilities. They can also beconfigured to interface with digital switch type inputs for low oil pressure andhigh coolant temperature shutdowns.

    Relays are provided for fuel solenoid output, start output and four additionalconfigurable outputs. On these configurable outputs a range of differentfunctions, conditions or alarms can be selected.

    INSTRUMENTATIONThe modules provide advanced metering facilities, displaying the information on theLCD display. The information can be accessed using the the five-key menunavigation to the left of the display.

    RELATEDMATERIALSTITLE PART NOSDSE7xxx Manual 057-074DSE72xx/73xx PC Software Manual 057-077DSE2130 Data Sheet 053-060DSE2157 Data Sheet 053-061DSE2548 Data Sheet 053-062

    DSENETDSENet is a collection of expansionmodules that have been created towork with DSENet compatiblecontrol modules. DSENet allows upto 20 different expansion devices tobe used at a time. 10 of thesedevices can be of the same type(excluding DSE2130). The expansionmodules available are:

    Available NowDSE2157 Relay Output ExpansionModuleDSE2130 Input Expansion ModuleDSE2548 Annunciator Module

    Coming SoonFET Output Expansion ModuleRemote Mimic ModuleNFPA 110 Interface ModuleRemote Display ModuleIdentification Dongle

    EVENT LOGThe module includes acomprehensive event log that showsthe 50 most recent alarm conditionsand the date and time that theyoccurred. This function assists theuser when fault finding andmaintaining a generating set.

    ELECTRONIC ENGINECOMPATABILITY CAT Cummins Deutz John Deere MTU Perkins Scania Volvo Generic Plus additional manufacturers

    7310 7320

    Generator InstrumentsVolts, Hz, Amps, kW, kVA, Pf, kWh, kVAr,kVArh, KVAh

    Engine InstrumentsRPM, Oil Pressure, Coolant Temperature,Hours Run, Charging Voltage, Battery Volts.

    Electronic EnginesEnhanced Instrumentation and Engine ECUdiagnostics via electronic engine interface.

    Generator InstrumentsVolts, Hz, Amps, kW, kVA, Pf, kWh, kVAr,kVArh, KVAh

    Engine InstrumentsRPM, Oil Pressure, Coolant Temperature,Hours Run, Charging Voltage, Battery Volts.

    Electronic EnginesEnhanced instrumentation and Engine ECUdiagnostics via electronic engine interface.

    Mains/Utility InstrumentsVolts, Frequency, Amps (optional whenCTs are fitted load side of the line)

    TESTINGSTANDARDS

    SPECIFICATION

    MAGNETIC PICKUP

    RELAYOUTPUTS

    DIMENSIONS

    ELECTRICAL SAFETY/ELECTROMAGNETIC COMPATIBILITY

    ENVIRONMENTAL

    VOLTAGERANGE+/- 0.5V minimum (during cranking) to 70V peak

    FREQUENCY RANGE10,000 Hz (max)

    OUTPUT A (FUEL)15 Amp DC at supply voltage

    OUTPUT B (START)15 Amp DC at supply voltage

    OUTPUTSC&D8 Amp 250V (Volt free)

    AUXILIARYOUTPUTS E,F,G,H2 Amp DC at supply voltage

    OVERALL240mm x 181.1mm x 41.7mm9.4 x 7.1 x 1.6

    PANEL CUT-OUT220mm x 160mm8.7 x 6.3Max panel thickness 8mm ( 0.3)

    BS EN 60950Safety of Information Technology Equipment,including Electrical Business Equipment

    BS EN 61000-6-2EMC Generic Immunity Standard (Industrial)

    BS EN 61000-6-4EMC Generic Emission Standard (Industrial)

    BS EN 60068-2-1Cold Temperature -30oC

    BS EN 60068-2-2Hot Temperature +70oC

    BS EN60068-2-30 HUMIDITYTest Db cyclic93% RH @ 40oC for 48 hours

    BS EN 60068-2-6 VIBRATION10 sweeps at 1 octave/minute in each of 3major axes5Hz to 8Hz @ +/-7.5mm constant displacement8Hz to 500Hz @ 2gn constant acceleration

    BS EN 60068-2-27 SHOCK3 half sine shocks in each of 3 major axes15gn amplitude, 11mS duration

    BS EN 60529 DEGREESOF PROTECTIONPROVIDED BY ENCLOSURES IP65 (Front of module when installed into the

    control panel with the supplied sealinggasket)

    NEMARATING (APPROXIMATE) 12 (Front of module when installed into the

    control panel with the supplied sealinggasket)

    DSE 7310-20 US v2:Layout 1 13/6/08 10:19 Page 3

  • DSE7310 & 7320WIRINGDIAGRAM

    BATTERY

    -VE

    +VE CHGALT

    OIL

    WATER

    FUEL

    (FLE

    XIBLE

    )

    SENDERCOMMON

    FLEXIBLE

    8 INPUTSPLANT +VE

    GENERATORLOADING RELAY

    OUTPUT D

    MAINSLOADING

    RELAY(7320)OUTPUT C

    (ALL MODELS)FLEXIBLE IFJ1939 IN USE

    FLEXIBLE IFJ1939 IN USE 4 FET OUTPUTS

    ENGINE ECU

    MPU

    SCR

    SCR

    H L

    BATTERY NEGATIVE MUST BE GROUNDED

    TERMINALS SUITABLE FOR 22-16 AWG (0.6mm - 1.3mm )FIELD WIRING

    TIGHTENING TORQUE = 0.8Nm (7lb-in)

    NOTE 1THESE GROUND CONNECTIONS MUST BE ON THEENGINE BLOCK, AND MUST BE TO THE SENDER BODIES.THE GROUND WIRE TO TERMINAL 15 MUST NOT BEUSED TO PROVIDE A GROUND CONNECTION TO ANYOTHER DEVICE

    *NOTE 2. 120 R TERMINATING RESISTORMAY BE REQUIRED EXTERNALLYSEE ENGINE MANUFACTURERS LITERATURE

    *

    NOTE 1

    CT1 CT2 CT3 N COM

    51 52 53 54 55 43 44 45 46 56 57 41 42 39 40 28 29 30 47 48 49 50 7 24 22 23

    1 2 3 4 5 6 16 17 18 19 15 60 61 62 63 64 65 66 67 8 9 10 11 27 25 26

    U V W N

    L1 L2 L3

    R S T NL1 L2 L3

    GEN VOLTS MAINS VOLTS

    + - SCRDSE NET

    HIGH SPEEDPERIPHERAL LINK

    GEN CURRENT

    EMERGENCYSTOP

    LOW

    OIL

    PRESSURE

    HIGHCOOLA

    NTTEMP

    FUELLE

    VELSENDER

    SENDER

    USERCONFIGURABLE

    -VEINPUTA

    USERCONFIGURABLE

    -VEINPUTB

    USERCONFIGURABLE

    -VEINPUTC

    USERCONFIGURABLE

    -VEINPUTD

    USERCONFIGURABLE

    -VEINPUTE

    USERCONFIGURABLE

    -VEINPUTF

    USERCONFIGURABLE

    -VEINPUTG

    USERCONFIGURABLE

    -VEINPUTH

    USERCONFIGURABLE

    +VEINPUTE

    USERCONFIGURABLE

    +VEINPUTF

    USERCONFIGURABLE

    +VEINPUTG

    USERCONFIGURABLE

    +VEINPUTH

    UPTO32

    AMPS

    FUSE

    MIN

    2AMPMAX20

    AMP

    ANIT-SURGEFU

    SE

    BATTERY

    FUELFUEL

    WL

    CRANK

    CHARGEALT

    2 AMPFUSES

    CTs 1 AMP OR 5 AMPSECONDARY

    PROTECTION CLASS

    P1 P2

    S1 S2

    MPU

    M

    2 AMPFUSES

    ELECTRICAL INTERLOCK

    MECHANICAL INTERLOCK

    LOAD

    L3

    N

    L2

    L1

    L3

    N

    L2

    L1

    FROMMAINS(UTILITY)

    FROMGENERATOR

    FUEL

    O/P

    A

    CRANK

    O/P

    B

    RS485

    RS232

    SCR

    B

    A

    PROGRAMMING PORT

    USB

    G

    DSE7320 ONLY

    MODULE 7310/7320

    DSE 7310-20 US v2:Layout 1 13/6/08 10:19 Page 4

  • 055-051/02/08 (2)

    YOUR LOCAL DISTRIBUTOR.

    DEEP SEA ELECTRONICS PLC maintains a policy of continuous development and reserves the right tochange the details shown on this data sheet without prior notice. The contents are intended for guidance only.

    This data sheet is printed on 9lives 55 Silk, which is produced with 55% recycled fibrefrom both pre and post-consumer sources, together with 45% virgin ECF fibre.

    DEEP SEA ELECTRONICS INC3230 Williams AvenueRockfordIL 61101-2668 USA

    TELEPHONE+1 (815) 316 8706

    FACSIMILE+1 (815) 316 8708

    [email protected]

    WEBSITEwww.deepseausa.com

    DEEP SEA ELECTRONICS PLCHighfield HouseHunmanby Industrial EstateHunmanby, North YorkshireYO14 0PH England

    TELEPHONE+44 (0)1723 890099

    FACSIMILE+44 (0)1723 893303

    [email protected]

    WEBSITEwww.deepseaplc.com

    Registered in England & Wales No.01319649 VAT No.316923457

    DSE 7310-20 US v2:Layout 1 13/6/08 10:19 Page 1