1 ENERGY RECOVERY AND OPTIMIZATION FOR A COMPLEX GAS COMPRESSION FACILITY CASE STUDY: TURBOMACHINERY PERFORMANCE AND PROCESS OPTIMIZATION CASE STUDY Executive Summary: Economic Value With more than four decades of proven expertise, Compressor Controls Corporation (CCC) is the recognized global leader in turbomachinery optimization. Our experience spans four key domains—process, machinery, instrumentation and control—and thousands of machinery control solutions across industries. At the core of CCC’s expertise is using turbomachinery optimization to deliver tangible economic benefits for our global customers. When CCC conducted a Preventive Maintenance (PM) visit for a major national oil and gas company in the Middle East, it identified an opportunity to optimize the turbomachinery of its gas compression facility. By implementing our five-step turbomachinery performance and process optimization strategy, CCC identified and implemented improvements that saved the end user $1.864 million per year in fuel gas consumption alone Process Background A major national oil and gas company in the Middle East operates a complex gas compression facility. After compressing natural gas from multiple feeders, the plant supplies it to several major gas processing and Natural Gas Liquids (NGL) facilities. The simplified process diagram of this complex facility is illustrated in Figure 1. The gas compression facility is equipped with two parallel medium-pressure (MP) booster compressors (13-C102 and 113-C102), which are driven by Dresser-Rand and Siemens gas turbines, respectively. Combining the MP booster compressors and other incoming MP feeds, the facility’s MP manifold feeds the high-pressure (HP) trains through two flow controllers (FIC-1051A/B). An HP compression section includes older northside parallel trains and newer southside parallel trains that receive the gas from the MP manifold and other feeds such as the end users’ onshore HP feed and remote onshore HP/ lean gas feed. The main objective of the HP facilities is to prioritize gas delivery among three main end-user gas processing facilities. The facility’s northside HP gas compression is achieved by two parallel gas-turbine driven compressors supplied by Dresser-Rand (13-C-101 A/B). The southside’s HP gas compression is performed by two parallel gas turbine-driven compressors supplied by Siemens (113- C-101 A/B). All the facility’s MP and HP compressors are equipped with CCC anti-surge controllers, which calculate and monitor the compressor proximity-to-surge variable and send an appropriate control response to the respective stage recycle valve. The current CCC control system also features a master pressure controller that controls the suction header pressure of each pair of MP, HP-North and HP-South compressor trains. This master pressure controller sends its control response to a load-sharing controller dedicated to each compressor, ensuring that the two compressors in a parallel set are equally loaded based on its compressor proximity- to-surge calculated variable. The control system

Upload: others

Post on 06-Jun-2020

12 views

Category:

Documents


1 download

TRANSCRIPT

Page 1: CASE STUDY: TURBOMACHINERY PERFORMANCE AND …...CASE STDY: TROMACINERY PERFORMANCE AND PROCESS OPTIMIZATION CASE STDY ENERGY RECOVERY AND OPTIMIZATION FOR A COMPLEX GAS COMPRESSION

1

C A S E S T U D Y : T U R B O M A C H I N E R Y P E R F O R M A N C E A N D P R O C E S S O P T I M I Z A T I O N C A S E S T U D Y

ENERGY RECOVERY AND OPTIMIZATION FOR A COMPLEX GAS COMPRESSION FACILITY

C A S E S T U D Y : T U R B O M A C H I N E R Y P E R F O R M A N C E A N D P R O C E S S O P T I M I Z A T I O N C A S E S T U D Y

Executive Summary: Economic ValueWith more than four decades of proven expertise, Compressor Controls Corporation (CCC) is the recognized global leader in turbomachinery optimization. Our experience spans four key domains—process, machinery, instrumentation and control—and thousands of machinery control solutions across industries. At the core of CCC’s expertise is using turbomachinery optimization to deliver tangible economic benefits for our global customers.

When CCC conducted a Preventive Maintenance (PM) visit for a major national oil and gas company in the Middle East, it identified an opportunity to optimize the turbomachinery of its gas compression facility. By implementing our five-step turbomachinery performance and process optimization strategy, CCC identified and implemented improvements that saved the end user $1.864 million per year in fuel gas consumption alone

Process BackgroundA major national oil and gas company in the Middle East operates a complex gas compression facility. After compressing natural gas from multiple feeders, the plant supplies it to several major gas processing and Natural Gas Liquids (NGL) facilities. The simplified process diagram of this complex facility is illustrated in Figure 1. The gas compression facility is equipped with two parallel medium-pressure (MP) booster compressors (13-C102

and 113-C102), which are driven by Dresser-Rand and Siemens gas turbines, respectively. Combining the MP booster compressors and other incoming MP feeds, the facility’s MP manifold feeds the high-pressure (HP) trains through two flow controllers (FIC-1051A/B). An HP compression section includes older northside parallel trains and newer southside parallel trains that receive the gas from the MP manifold and other feeds such as the end users’ onshore HP feed and remote onshore HP/lean gas feed. The main objective of the HP facilities is to prioritize gas delivery among three main end-user gas processing facilities.

The facility’s northside HP gas compression is achieved by two parallel gas-turbine driven compressors supplied by Dresser-Rand (13-C-101 A/B). The southside’s HP gas compression is performed by two parallel gas turbine-driven compressors supplied by Siemens (113-C-101 A/B). All the facility’s MP and HP compressors are equipped with CCC anti-surge controllers, which calculate and monitor the compressor proximity-to-surge variable and send an appropriate control response to the respective stage recycle valve. The current CCC control system also features a master pressure controller that controls the suction header pressure of each pair of MP, HP-North and HP-South compressor trains. This master pressure controller sends its control response to a load-sharing controller dedicated to each compressor, ensuring that the two compressors in a parallel set are equally loaded based on its compressor proximity-to-surge calculated variable. The control system

Page 2: CASE STUDY: TURBOMACHINERY PERFORMANCE AND …...CASE STDY: TROMACINERY PERFORMANCE AND PROCESS OPTIMIZATION CASE STDY ENERGY RECOVERY AND OPTIMIZATION FOR A COMPLEX GAS COMPRESSION

2

C A S E S T U D Y : T U R B O M A C H I N E R Y P E R F O R M A N C E A N D P R O C E S S O P T I M I Z A T I O N C A S E S T U D Y

accomplishes this by sending the control response to the gas turbine speed controller.

Identifying the ProblemCCC has an added value service agreement with this end user, through which it conducts regularly scheduled Preventive Maintenance (PM) visits. In addition to verifying that the installed CCC control equipment is functioning correctly, we use these visits to identify new opportunities for turbomachinery optimization and/or enhancement. For this reason, we monitor the mechanical condition of the end-user’s rotating

equipment, associated measuring equipment and

control valves. We also collaborate with the end-user

personnel responsible for interpreting this gathered

data, leveraging our collective expertise to identify the

proper course of action based on the findings.

During recent PM visits, CCC observed that the load

sharing/balancing controllers for the MP and HP

machines were set to manual. Likewise, the remote

anti-surge/recycle valves opening setpoints (Remote Low

Clamp “RLOC” (1)) were set manually by the operator in

the DCS, as shown in Table 1.

PT3650

AI

MPIC3650

MP M

ANIFO

LD

13-C102

PV-3074

PT3074

PIC3074

FV-1051A

FIC1051A

FT1051A

Approx. 4 ~ 5 km of piping distance between trains.

PT3111

PIC3111

PV-3112

PT3112

PIC3112

FV-1051B

FIC1051B

FT1051B

End-user’s facility 1

End-user’s facility 2 FV-801

FIC801

FT801

End-user’s facility 3FV-1103

FIC1103

FT1103

PV-802

PT802

PIC802

End-user’s facility 1

NOT OPERATIONAL

NORMALLY FORCED FULLY OPEN BY HIGH

SET POINT VALUE

PV-3032

PT3032

PIC3032

PV-3031

PT3031

PIC3031

End-user’sMP Feeder

FROM LP TRAINS12-C-102 & 112-C-102

End-use’srHP Feeder

End-user’s WellsHP / LEAN GAS

Feeder

13-V-107

113-V-107

113-C102

PV

SP

SP

PV

13-C101 A

13-C101 B

PV

PV

SP

PV

113-C101 A

113-C101 B

PV

PV

MP COMPRESSION HP COMPRESSION

MP COMPRESSION HP COMPRESSION

NORTH

SOUTH

PV-3125

PT3125

PIC3125

PV

FROM MP SEPARATOR

24-V-109

FROM MP SEPARATOR

122-V-107

FROM MP SEPARATORS20/21/22-V-107

NORMALLY FORCED FULLY OPEN BY HIGH

SET POINT VALUE

PT3082

AI

MPIC3082

PT3036

AI

UIC7638

Figure 1 – Process Schematic Overview

Page 3: CASE STUDY: TURBOMACHINERY PERFORMANCE AND …...CASE STDY: TROMACINERY PERFORMANCE AND PROCESS OPTIMIZATION CASE STDY ENERGY RECOVERY AND OPTIMIZATION FOR A COMPLEX GAS COMPRESSION

3

C A S E S T U D Y : T U R B O M A C H I N E R Y P E R F O R M A N C E A N D P R O C E S S O P T I M I Z A T I O N C A S E S T U D Y

Although CCC’s anti-surge controllers protected the compressors against surge, the RLOC high opening setting on the anti-surge/recycle valves was generating significant recycle gas flow relative to the compressors’ suction. This excessive flow caused the unit’s power/energy consumption to exceed process demand.

After conducting a turbomachinery controls audit, CCC investigated why the load sharing controllers were being manually operated. Most likely, the poor behavior of the speed controllers and unstable machine suction/input conditions had led the operating personnel to run the machines manually at higher constant speeds and adjust capacity via recycling.

Reducing the operating speed and eliminating excessive gas recycle could deliver potentially significant savings. It could also resolve some unbalanced operating conditions that had resulted from manually setting the load sharing controllers. One parallel compressor was running on a higher speed than its companion, with the production flow sustained

only by the compressor with the lower speed. Under this strategy, the speed control is set manually, and each compressor runs continuously at full load. These swings in station load are met by the recirculation of gas around the compressors. This inefficient system wastes

significant energy.

During the CCC turbomachinery audit, we also determined that surge tests had never been conducted on most machines. This was likely due to the old conventional wisdom that having high Surge Control Margins usually results in higher machine availability. Under this assumption, higher energy consumption is not only tolerated but viewed as “inevitable.” Because surge testing had not been performed, each machine’s surge controller(s) was configured with the Surge Limit Line either predicted by the OEM or

determined via the OEM’s test bench. This increases the probability of excessive Surge Control Margins.

CCC typically recommends conducting an onsite surge test. This not only determines the true Surge Limit Line

Compressor Tag

Antisurge Valve Opening Antisurge Controller

Load Sharing Controller

Master

Controller 1st Stage 2nd Stage 1st Stage 2nd Stage

13-C-101A 19 % 23%

Auto ☒

Manual ☐

RLOC(1) ☐

Auto ☒

Manual ☐

RLOC(1) ☐

Auto ☐

Manual ☒ Suction Header Pressure Control

Auto ☐

Manual ☒ 13-C-101B 19% 19%

Auto ☒

Manual ☐

RLOC(1) ☐

Auto ☒

Manual ☐

RLOC(1) ☐

Auto ☐

Manual ☒

113-C-101A 7~14% 10~18%

Auto ☒

Manual ☐

RLOC(1) ☐

Auto ☒

Manual ☐

RLOC(1) ☒

Auto ☐

Manual ☒

Suction Header Pressure Control

Auto ☐

Manual ☒ 113-C-101B 7~13% 10~20%

Auto ☒

Manual ☐

RLOC(1) ☐

Auto ☒

Manual ☐

RLOC(1) ☒

Auto ☐

Manual ☒

13-C-102 58% 48%

Auto ☒

Manual ☐

RLOC(1) ☒

Auto ☒

Manual ☐

RLOC(1) ☒

Auto ☐

Manual ☒

Suction Header Pressure Control

Auto ☐

Manual ☒ 113-C-102 49% 51%

Auto ☒

Manual ☐

RLOC(1) ☒

Auto ☒

Manual ☐

RLOC(1) ☒

Auto ☐

Manual ☒

Table 1 – Compressors Operating Configuration And Setpoints As Found

(1) RLOC = Remote Low Output Clamp to allow the Operator to force the Anti-surge valve more open than required by the surge control algorithm.

Page 4: CASE STUDY: TURBOMACHINERY PERFORMANCE AND …...CASE STDY: TROMACINERY PERFORMANCE AND PROCESS OPTIMIZATION CASE STDY ENERGY RECOVERY AND OPTIMIZATION FOR A COMPLEX GAS COMPRESSION

4

C A S E S T U D Y : T U R B O M A C H I N E R Y P E R F O R M A N C E A N D P R O C E S S O P T I M I Z A T I O N C A S E S T U D Y

of the machine, but also eliminates potential errors in the predicted or OEM PTC-10 testing. In CCC’s experience, two types of errors can affect the predicted or OEM PTC-10 derived Surge Limit Line:

■ Onsite piping characteristics and the actual gasses being used can cause a significant shift in the predicted Surge Limit Line

■ The onsite flow measurement device is different than that being used in the OEM’s PTC-10 testing and therefore could result in significantly different values for the same surge point onsite.

However, in this case, the plant stakeholders had implemented a new strategy that emphasized running their turbomachinery in the most efficient manner and avoiding nuisance trips.

Solution and OutcomesAfter finalizing the diagnostic agreement with the end user, CCC began conducting a detailed study that quantified the economic value of our services. Using the CCC TrainView historian and operational trends that provided high-quality plant data capture and storage, we implemented a five-step turbomachinery and process optimization solution.

Step 1: Survey Site and Collect DataThe first step to properly quantifying the required optimization and expected savings was to survey the installation. During this step, CCC engaged directly with various site stakeholders, including operation and maintenance teams. After collecting site historical and operational data, we conducted a preliminary review to identify the production profile of relevant processes, compressors and turbine parameters.

Step 2: Analyze Data and Assess Operating Conditions

After our preliminary review of the site data, we performed multiple analyses to assess current operating conditions. These analyses included:

■ A detailed review of the site’s existing P&IDs and piping configuration for each compressor’s anti-surge system. Through this analysis, CCC ensured that the systems are appropriately configured for continuous recycle duty and do not have deficiencies.

■ A validation that the existing anti-surge valve capacity was adequate to suit the OEM’s predicted performance curves.

■ A validation of historical operation conditions such as flow (differential pressure), suction and discharge pressure and temperature transmitter, including an analysis of the transmitter calibration spans used onsite for all proximity-to-surge calculation algorithms.

Step 3: Calculate Improvement, Economic Benefits and ROI Leveraging our operating conditions analysis, CCC calculated the energy savings derived from two key areas:

1. Reduced Recycled Rates: Surge protection margins could be set too conservatively inside the anti-surge control system, or the recycle valves could be clamped open by the operator. This unnecessary opening of the anti-surge valves causes excessive gas to recycle. Because of this excessive recycle, the unit’s power consumption exceeds process demand—representing an associated energy penalty. Figure 2 illustrates the first stage performance map for the 113-C102 compressor, during which the compressor’s operating point is away from the Surge Control Line. CCC highlighted the benefit of reducing the recycle valve opening from 33.84% to 3%, which subsequently allowed for the reduction of the compressor speed to 83.5% = 4846 rpm. This optimization would satisfy the process needs of flow and discharge pressure, while potentially reducing the compressor stage’s power consumption from 4690 kW to 2490 kW.

2. Automated Capacity Control and Load-sharing. The ideal way to distribute the load between parallel compressors is to operate each compressor at the

Page 5: CASE STUDY: TURBOMACHINERY PERFORMANCE AND …...CASE STDY: TROMACINERY PERFORMANCE AND PROCESS OPTIMIZATION CASE STDY ENERGY RECOVERY AND OPTIMIZATION FOR A COMPLEX GAS COMPRESSION

5

C A S E S T U D Y : T U R B O M A C H I N E R Y P E R F O R M A N C E A N D P R O C E S S O P T I M I Z A T I O N C A S E S T U D Y

same relative distance from its Surge Control Line. As the load is decreased, this approach causes all the compressors to reach their Surge Control Lines simultaneously, allowing all anti-surge valves to be throttled opened at the same time. Through this strategy, the parallel network achieves the best possible turndown prior to any opening of the anti-surge valves. This method helps minimize the amount of recycle required for low plant loads, resulting in the most energy-efficient operation possible.

As a result of CCC’s turbomachinery audit, we identified potential energy savings of $4,078.4 per day per machine. This translates to approximately $ 1.5 million of annual energy savings—achieved purely by optimizing the existing turbomachinery control system’s compressor operations.

Step 4: Deliver Report and Conduct Onsite Implementation DiscussionAfter submitting our turbomachinery audit report, CCC and the end user held a discussion to determine the best strategy for implementing the recommendations. We agreed upon detailed surge test procedures and a full schedule of required site activities.

Step 5: Implement Site Activities and Assess OutcomesCCC and the end user conducted successful surge tests for all MP and HP compressors. CCC utilized the test results to verify and update each compressor’s surge line. Once the anti-surge controllers’ configurations were optimized, the compressor speeds and RLOC setpoints were both reduced successfully. Tables 2 through 4 illustrate the percentage of savings in compressor speed and recycle/anti-surge valve opening.

During the surge testing, CCC discovered that the machines’ speed controller functionality was unable to maintain the assigned speed set-point—an issue that would need to be remedied with the OEMs. These speed governor challenges prevented us from toggling the CCC load sharing/balancing controllers to automatic. Because

of this, performance controls remained in manual, with some trains requiring particular RLOC setpoint values until the speed governor issues were resolved.

Although not all CCC recommended actions have been implemented, the end user has witnessed significant saving in MP and HP train fuel gas consumption. The total fuel gas savings alone equal $5,106 per day, or $1.864 million per year.

In addition to these fuel gas savings, the end user has achieved unquantified economic benefits: a reduction in CO2 emissions and the machines’ speed reduction, which enhances availability and optimizes scheduled/unscheduled maintenance.

Figure 2 – 113-C102 1st Stage Compressor Performance Map Showing The Expected Operating Point If The

Recycle Valve Closed

Current OP

83.5% =

4567 rpm

100.4% = 5493 rpm

83.5% = 4846 rpm

100.4% =

5493 rpm

2.49 kw

4.69 kw

Page 6: CASE STUDY: TURBOMACHINERY PERFORMANCE AND …...CASE STDY: TROMACINERY PERFORMANCE AND PROCESS OPTIMIZATION CASE STDY ENERGY RECOVERY AND OPTIMIZATION FOR A COMPLEX GAS COMPRESSION

6

C A S E S T U D Y : T U R B O M A C H I N E R Y P E R F O R M A N C E A N D P R O C E S S O P T I M I Z A T I O N C A S E S T U D Y

0.00

1,000.00

2,000.00

3,000.00

4,000.00

5,000.00

6,000.00

7,000.00

8,000.00

9,000.00

13C102 13C101A 13C101B 113C102 113C101A 113C101B

PT speed (rpm)

Before mapping After mapping

0

10

20

30

40

50

60

70

13C102 13C101A 13C101B 113C102 113C101A 113C101B

1st Anti-surge valve opening (%)

Before mapping After mapping

0

10

20

30

40

50

60

13C102 13C101A 13C101B 113C102 113C101A 113C101B

Before mapping After mapping

2nd Anti-surge valve opening (%)

0

2

4

6

8

10

12

14

16

13C102, and13C101A/B

113C102 113C101A 113C101B

Fuel Gas Flow_KNm3/h

Before mapping After mapping

Figure 3 – PT Speed (rpm)

Figure 4 – 1st Anti-surge valve opening (%) Figure 5 – 2nd Anti-surge valve opening (%)

0.00

1,000.00

2,000.00

3,000.00

4,000.00

5,000.00

6,000.00

7,000.00

8,000.00

9,000.00

13C102 13C101A 13C101B 113C102 113C101A 113C101B

PT speed (rpm)

Before mapping After mapping

0

10

20

30

40

50

60

70

13C102 13C101A 13C101B 113C102 113C101A 113C101B

1st Anti-surge valve opening (%)

Before mapping After mapping

0

10

20

30

40

50

60

13C102 13C101A 13C101B 113C102 113C101A 113C101B

Before mapping After mapping

2nd Anti-surge valve opening (%)

0

2

4

6

8

10

12

14

16

13C102, and13C101A/B

113C102 113C101A 113C101B

Fuel Gas Flow_KNm3/h

Before mapping After mapping

0.00

1,000.00

2,000.00

3,000.00

4,000.00

5,000.00

6,000.00

7,000.00

8,000.00

9,000.00

13C102 13C101A 13C101B 113C102 113C101A 113C101B

PT speed (rpm)

Before mapping After mapping

0

10

20

30

40

50

60

70

13C102 13C101A 13C101B 113C102 113C101A 113C101B

1st Anti-surge valve opening (%)

Before mapping After mapping

0

10

20

30

40

50

60

13C102 13C101A 13C101B 113C102 113C101A 113C101B

Before mapping After mapping

2nd Anti-surge valve opening (%)

0

2

4

6

8

10

12

14

16

13C102, and13C101A/B

113C102 113C101A 113C101B

Fuel Gas Flow_KNm3/h

Before mapping After mapping

Page 7: CASE STUDY: TURBOMACHINERY PERFORMANCE AND …...CASE STDY: TROMACINERY PERFORMANCE AND PROCESS OPTIMIZATION CASE STDY ENERGY RECOVERY AND OPTIMIZATION FOR A COMPLEX GAS COMPRESSION

7

C A S E S T U D Y : T U R B O M A C H I N E R Y P E R F O R M A N C E A N D P R O C E S S O P T I M I Z A T I O N C A S E S T U D Y

SummaryWith more than four decades of proven expertise, Compressor Controls Corporation (CCC) is the recognized global leader in turbomachinery optimization. At the core of that expertise is the ability to deliver tangible economic benefits for our global customers. By implementing our proven turbomachinery performance and process optimization strategy, CCC helped a gas compression facility save $1.864 million per year simply by improving the existing turbomachinery control system’s compressor operations. The end user has also lowered its carbon footprint and the speed of its machines, which enhances availability and optimizes scheduled/unscheduled maintenance.

0.00

1,000.00

2,000.00

3,000.00

4,000.00

5,000.00

6,000.00

7,000.00

8,000.00

9,000.00

13C102 13C101A 13C101B 113C102 113C101A 113C101B

PT speed (rpm)

Before mapping After mapping

0

10

20

30

40

50

60

70

13C102 13C101A 13C101B 113C102 113C101A 113C101B

1st Anti-surge valve opening (%)

Before mapping After mapping

0

10

20

30

40

50

60

13C102 13C101A 13C101B 113C102 113C101A 113C101B

Before mapping After mapping

2nd Anti-surge valve opening (%)

0

2

4

6

8

10

12

14

16

13C102, and13C101A/B

113C102 113C101A 113C101B

Fuel Gas Flow_KNm3/h

Before mapping After mapping

Figure 6 – Fuel Gas Flow KNm3/h