calibrator uniq system - bogballe

3
2002.10.10 / UNIQ-GB 1 CALIBRATOR UNIQ Technical Factors Weighing technique W signals : 1,67 / 1.000.000 V/Kg (1,67 μV/Kg) Uploading 50 times / sek. 6 Tons load cell divided into 110.000 units, identical to 55 gram/ unit Load cell physical bending: 2/10 mm / 6.000 Kg. (0,00003333 mm/Kg) Automatic temperature correction from -20ºC to +70ºC Reg. technique Actuator control : Thermal protection against overload and over current. CALIBRATOR UNIQ HW dimensioned to maximum long time current of 39 A PI controlled actuator / never goes too far / deceleration at end goal. Trend Integrated intelligence : Integrated CAN-bus controller built in . Bosch developer to car industry Automatic fault corrections by ex. electrical noise Prepared for adding extra equipment ex. Extra actuator etc. Communication Electronic: RS 232 seriel communication w/ 2 times serial ports, integrated in one plug RS 232 plug w/ 1 stk. integrated CAN bus communication AMP 4 pol f/ CAN communication – f/ ex. ISO 11783 Power System flexibility : Wide power area with wide intervals – stabil supply: 10 – 16 V Temperature area: -20º C / +70º C SW-programmable digital inputs (Speed, PTO, Tank and Flow) Very fast adapted inputs – speed up to ”MACH 2,5” When booting the system automatically optimizes all internal power supplies Internal 2 Mb ram RISC 32-bit processor (Automotiv app.), 512 Kb flash, 32 Kb F-ram (logfile)

Upload: others

Post on 16-Jun-2022

3 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: CALIBRATOR UNIQ System - Bogballe

2002.10.10 / UNIQ-GB 1

CALIBRATOR UNIQ Technical FactorsWeighing technique W signals :

1,67 / 1.000.000 V/Kg (1,67 µV/Kg)

Uploading 50 times / sek.6 Tons load cell divided into 110.000 units, identical to 55 gram/ unitLoad cell physical bending: 2/10 mm / 6.000 Kg. (0,00003333 mm/Kg)

Automatic temperature correction from -20ºC to +70ºC

Reg. technique Actuator control :Thermal protection against overload and over current. CALIBRATOR UNIQ HW dimensioned to maximum long time current of 39 API controlled actuator / never goes too far / deceleration at end goal.

Trend Integrated intelligence :Integrated CAN-bus controller built in . Bosch developer to car industryAutomatic fault corrections by ex. electrical noisePrepared for adding extra equipment ex. Extra actuator etc.

Communication Electronic:RS 232 seriel communication w/ 2 times serial ports, integrated in one plugRS 232 plug w/ 1 stk. integrated CAN bus communicationAMP 4 pol f/ CAN communication – f/ ex. ISO 11783

Power System flexibility : Wide power area with wide intervals – stabil supply: 10 – 16 VTemperature area: -20º C / +70º CSW-programmable digital inputs (Speed, PTO, Tank and Flow)Very fast adapted inputs – speed up to ”MACH 2,5”When booting the system automatically optimizes all internal power suppliesInternal 2 Mb ramRISC 32-bit processor (Automotiv app.), 512 Kb flash, 32 Kb F-ram (logfile)

Page 2: CALIBRATOR UNIQ System - Bogballe

2002.10.10 / UNIQ-GB 2

①CALIBRATOR UNIQ System - complete

AL TEKNIK6 Ton

AL TEKNIK6 Ton

Red AMP no. 18 Power (-)Yellow AMP no. 19 Power (-)White AMP no. 20 Power (+)Green AMP no. 21 Power (+)Brown AMP no. 08 POT BBlue AMP no. 09 POT WBlack AMP no. 10 POT T

Yellow AMP no. 12 W-Signal (-)Brown AMP no. 11 W-Power (+)White AMP no. 17 W-Signal (+)Green AMP no. 06Shield AMP no. 13

Brown AMP no. 16 PTO (+)White AMP no. 15 Trend (-)/PTO (-)Green AMP no. 01 Trend (+)Yellow AMP no. 22 Trend-SignalPink AMP no. 14 Tank- ReferenceGrey AMP no. 03 Tank-SignalBlue AMP no. 07 Free ⑥

Green AMP no. 01Grey AMP no. 03Green AMP no. 06Blue AMP no. 07Brown AMP no. 08Blue AMP no. 09Black AMP no. 10Brown AMP no. 11Yellow AMP no. 12Shield AMP no. 13Pink AMP no. 14White AMP no. 15Brown AMP no. 16White AMP no. 17Red AMP no. 18Yellow AMP no. 19White AMP no. 20Green AMP no. 21Yellow AMP no. 22

②③

Reg. Actuator, LA 32⑩

Load cell 6 Ton⑨

PTO-sensor – Reedw/ magnetic sensing⑧

Trend Actuator, LA 12Trend UNIQ w/ CAN-comm.⑦

Connectionboxw/ 9 + 1 connections⑥

AMP 22 pol – Femalew/ Fix screw⑤

AMP 22 pol – Malew/ bracket and lid④

Speed Sensor – Induktivw/ Ferredic iron sensing③

Fuse part w/ 8 Amp. fuse± 12 V (Min. 10 V – Max. 14 V)

CALIBRATOR UNIQ①PARTPOS

Page 3: CALIBRATOR UNIQ System - Bogballe

2002.10.10 / UNIQ-GB 3

CALIBRATOR UNIQ Connection-box

Load cell(s)

PTO

Trend

Tank

1

6

Shield

2

3

4

5

7

89

W-Power (-)Green

W-Signal (+)White

W-Power (+)Brown

W-Signal (-)Yellow

PTO-Signal (+)Brown

PTO-Signal (-)Blue

Trend-signalBlack

AMP no. 6Green

AMP no. 17White

AMP no. 11Brown

AMP no. 12Yellow

AMP no. 16Brown

AMP no. 15White

AMP no. 1Green

AMP no. 22Yellow

Trend (-)White

Tank (-)Blue

Trend (+)Red

Tank (+)Brown Tank-Signal

BlackAMP no. 14PinkAMP no. 3Gray

Shield