A system with the high capacity needed to suit large-sized buildings COOLING ONLY Cooling Only 50 Hz PCV0620 All rights reserved Printed in Japan 01/07/003 Y.K. c Dealer Head Office: Umeda Center Bldg., 2-4-12, Nakazaki-Nishi, Kita-ku, Osaka, 530-8323 Japan Tokyo Office: JR Shinagawa East Bldg., 2-18-1, Konan, Minato-ku, Tokyo, 108-0075 Japan http://www.daikin.com/global/ 1. Air conditioners should not be installed in areas where corrosive gases, such as acid gas or alkaline gas, are produced. 2. If the outdoor unit is to be installed close to the sea shore, direct exposure to the sea breeze should be avoided. If you need to install the outdoor unit close to the sea shore, contact your local distributor. Cautions on product corrosion Warning Daikin Industries, Ltd.’s products are manufactured for export to numerous countries throughout the world. Daikin Industries, Ltd. does not have control over which products are exported to and used in a particular country. Prior to purchase, please therefore confirm with your local authorised importer, distributor and/or retailer whether this product conforms to the applicable standards, and is suitable for use, in the region where the product will be used. This statement does not purport to exclude, restrict or modify the application of any local legislation. Ask a qualified installer or contractor to install this product. Do not try to install the product yourself. Improper installation can result in water or refrigerant leakage, electrical shock, fire or explosion. Use only those parts and accessories supplied or specified by Daikin. Ask a qualified installer or contractor to install those parts and accessories. Use of unauthorised parts and accessories or improper installation of parts and accessories can result in water or refrigerant leakage, electrical shock, fire or explosion. Read the User's Manual carefully before using this product. The User's Manual provides important safety instructions and warnings. Be sure to follow these instructions and warnings. If you have any enquiries, please contact your local importer, distributor and/or retailer. Printed on 100% recycled paper with soy ink. Specifications, designs and other content appearing in this brochure are current as of January 2007 but subject to change without notice. ISO 14001 is the standard defined by the International Organization for Standardization (ISO) relating to environmental management systems. Our group has been acknowledged by an internationally accredited compliance organisation as having an appropriate programme of environmental protection procedures and activities to meet the requirements of ISO 14001. About ISO 14001 ISO 9001 is a plant certification system defined by the International Organization for Standardization (ISO) relating to quality assurance. ISO 9001 certification covers quality assurance aspects related to the “ design, development, manufacture, installation, and supplementary service” of products manufactured at the plant. About ISO 9001 JMI-0107 JQA-1452

Upload: others

Post on 01-May-2022

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: C OOLING O - Premium Serve

A s ys tem with the high c apac ity needed to s uit large- s ized buildings

C OOL ING ONL YCooling Only50 Hz

PCV0620

All rights reservedPrinted in Japan 01/07/003 Y.K.c

DealerHead Office:Umeda Center Bldg., 2-4-12, Nakazaki-Nishi,Kita-ku, Osaka, 530-8323 Japan

Tokyo Office:JR Shinagawa East Bldg., 2-18-1, Konan,Minato-ku, Tokyo, 108-0075 Japan

http://www.daikin.com/global/

1. Air conditioners should not be installed in areas where corrosive gases, such as acid gas or alkaline gas, are produced.2. If the outdoor unit is to be installed close to the sea shore, direct exposure to the sea breeze should be avoided. If you need to install the outdoor unit close to the sea shore, contact your local distributor.

Cautions on product corrosion

Warning Daikin Industries, Ltd.’s products are manufactured for export to numerous countries throughout the world. Daikin Industries, Ltd. does not have control over which products are exported to and used in a particular country. Prior to purchase, please therefore confirm with your local authorised importer, distributor and/or retailer whether this product conforms to the applicable standards, and is suitable for use, in the region where the product will be used. This statement does not purport to exclude, restrict or modify the application of any local legislation.Ask a qualified installer or contractor to install this product. Do not try to install the product yourself. Improper installation can result in water or refrigerant leakage, electrical shock, fire or explosion.Use only those parts and accessories supplied or specified by Daikin. Ask a qualified installer or contractor to install those parts and accessories. Use of unauthorised parts and accessories or improper installation of parts and accessories can result in water or refrigerant leakage, electrical shock, fire or explosion.Read the User's Manual carefully before using this product. The User's Manual provides important safety instructions and warnings. Be sure to follow these instructions and warnings.

If you have any enquiries, please contact your local importer, distributor and/or retailer.

Printed on 100% recycled paper with soy ink.Specifications, designs and other content appearing in this brochure are current as of January 2007 but subject to change without notice.

ISO 14001 is the standard defined by the International Organization for Standardization (ISO) relating to environmental management systems. Our group has been acknowledged by an internationally accredited compliance organisation as having an appropriate programme of environmental protection procedures and activities to meet the requirements of ISO 14001.

About ISO 14001

ISO 9001 is a plant certification system defined by the International Organization for Standardization (ISO) relating to quality assurance. ISO 9001 certification covers quality assurance aspects related to the “ design, development, manufacture, installation, and supplementary service” of products manufactured at the plant.

About ISO 9001

JMI-0107 JQA-1452

Page 2: C OOLING O - Premium Serve

21

Latest individual air conditioning technology adds new real valueto today's buildings

Air conditioning systems that use new refrigerant and save energy are the norm. However, we at Daikin have gone much further by maximising our advanced technology developed over 20 years as the leading manufacturer of individual air conditioning systems. Not only top level air conditioning performance, we also offer minimal space utilisation, efficient building management and a multitude of other added value features.

Daikin’s VRV systems include indoor and outdoor units available in a wide range of models for various building sizes and installation conditions. Long refrigerant piping lengths and other features put few restrictions on design for great flexibility in meeting the needs of the building.

Daikin offers a compact design for VRVIII outdoor units by further optimising equipment functions, exceeding the norm for air conditioning systems. Compact units facilitate installation in limited areas, such as rooftops, and take up less effective space. Easier installation work realises fast completion with time to spare.

Benefits for INSTALLERS

With Daikin's proprietary inverter technology and cutting-edge control technology for refrigerant, the VRVIII air conditioning system operates with outstanding efficiency. This contributes to high energy savings that are top class in the industry, which greatly reduces your running costs and facilitates far better building management.

Benefits for

property OWNERS

To provide a comfortable air environment, Daikin offers air treatment systems beyond mere air conditioning. As well as bringing air to a comfortable temperature, the air quality can be treated with ventilation, humidification, and other processes. Ease of use is realised through advanced, centralised control systems.

Benefits for USERS

Benefits for CONSULTANTand DESIGN OFFICES

Page 3: C OOLING O - Premium Serve

43

Outdoor units with large capacities

Wide range and an increased number of connectable indoor units

High COPs/Energy savings

Compliant with the RoHS Directive

Extended level difference between outdoor units and indoor units

Extended actual and total maximum piping length

High external static pressure

Two types of outdoor unit combinations

Developed to facilitate more flexible system design in la r ge -s iz e d buildings

Memory function for operational data

Automatic test operation

Less chances of refrigerant leakage

Outdoor units designed for quiet operation

Efficient compressor

E a s ie r ins ta lla tion a nd m a inte na nc e

A s e ns e of r e s pons ibil ity

E nha nc e d c om for t

Nighttime quiet operation function

Daikin proudly introduc es the new VR VIII series , whic h is well-suited to large-s ized buildings . This new air c onditioning system provides outdoor units that extend air c onditioning c apac ity up to 54 HP. It also inc orporates numerous outstanding features , suc h as a wide range of outdoor and indoor units , longer ac tual and total piping length, and high external s tatic pressure. The VR VIII series provides the power and versatility you need for flexible des ign and easy installation in large-s ized buildings .

Content

Introduction.........page 1

Concept...............page 3

Technologies.......page 5

Main features......page 7

Control system....page 15

Indoor units line up.....page 25

Outdoor units line up..page 36

Outdoor unit type........page 37

Specifications.............page 38

Indoor units . . . . . . . . . . . . . . .page 38Outdoor units . . . . . . . . . . . .page 44

Option list..................................page 48

Indoor units . . . . . . . . . . . . . . . . . . .page 48Outdoor units . . . . . . . . . . . . . . . .page 50C ontrol s ys tems .. . . . . . . . . . .page 50

Air treatment systems line up..page 53

Outdoor-air proces s ing unit. . . . . . . .page 53HR V.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page 57

Page 4: C OOLING O - Premium Serve

Cutting-Edge Technologies

65

Daikin’s constant efforts have been devoted towards using the latest and most revolutionary technologies in the development of the VRVIII system for large-sized buildings. The system offers larger outdoor capacities, greater energy savings, easier installation, longer actual and total piping, and more.

VRVIII —Created to respond to the needs of large-sized buildings

The new heat exchanger contributes to a higher COP because of an increase from 7% to 10% of the effective length as well as an optimised e-Pass heat exchanger.

1

26

3

7

5

3

4

7

2

A higher external static pressure has been achieved–from 58. 8 Pa to 78.4 Pa–thanks to reduced internal pressure loss, use of the new fans and the new grilles.

The area of these new fan blades has been increased and optimised for each casing. This greatly reduces pressure loss, resulting in a higher external static pressure.

The three-bladed fan on the 10 HP unit, with a diameter of 700 mm, has been redesigned to include four blades and now has a diameter of 680 mm. Blade area has been increased by 25%.

1 N e w ly im p r o v e d f a n s a n d g r ille s

H e a t e x c h a n g e r

D C f a n m o t o r

4 H e a t t r a n s f e r c ir c u it

By performing super cooling before the expansion process, the volume of refrigerant that needs to be circulated to the indoor units can be reduced without lowering the evaporation temperature. This permits the use of narrower piping.

5 C o m p a c t a e r o b o x

Realises a compact casing by stacking the Inverter and control PCBs plus optimising the internal design to suit airflow speed. This achieves lower noise and reduces the power required by the large-diameter fanned outdoor unit.

• Across entire range of models (from 5 to 54 HP).• Efficiency improvement by up to 40% especially at low speed.

New

New

6 S m o o th s in e w a v e D C In v e r te r

By adoption of the Sine Wave, which smoothes the rotation of the motor, operation efficiency is improved sharply.

DC fan motorstructure

200 300 400 500 600 700 800 900 10000

20

40

80

60

100

Effic

ienc

y (%

)

Motor speed (rpm)

AC motorAC motorAC motor

DC motor efficiency (comparison with a conventional AC motor)

New aero spiral fan and aero asymmetrical fan

Aero smooth grille

New aero asymmetrical fanIn the 14 and 16 HP unit, a single fan with a diameter of 700 mm has been split into two fans with diameters of 540 mm each. Blade area has been increased by 20% to increase airflow.

New aero spiral fan (Powerful Dual DC fan)

Ferrite magnet

Secret to raising energy-efficiency! Powerful magnetsSecret to raising energy-efficiency! Powerful magnets

Neodymium magnets are much more powerful than the widely used ferrite magnets.

Neodymium magnet

ReluctanceDC motor

Im p r o v in g t h e h ig h e f f ic ie n c y c o m p r e s s o r t o a c h ie v ea h ig h e r C O P a n d la r g e r c a p a c it y

Reluctance DC scroll compressor

High torque and efficiency is attained by employing neodymiummagnets. Achieves 70% reduction in volume.

Daikin’s unique scroll compressor minimises heat loss, and is driven by a high efficiency motor to achieve significant energy savings.

By introducing high pressure oil, the reactive force from the fixed scroll is added to the internal force, thereby reducing thrust losses. This results in improved efficiency and suppressed sound levels.

High-performance, low-noise new scroll compressor operates at a faster rate. The speed increase has been achieved through advanced stress analysis for increased strength and utilisation of the advantages (oil film control) of the high thrust mechanism*.

*High thrust mechanismVRVII

The three-dimensional, integrated, soft woven steel grilles are covered with a plastic coating that protects them from rotating elements and the possibility of fire damage.

Blade area increased by2 5 % !

VRVIIBlade area increased by2 0 % !

Diameter of 700 mm Diameter of 540 mm x 2

Perspective view

New

Page 5: C OOLING O - Premium Serve

L a r g e c a p a c it ie s f o r la r g e - s iz e d b u ild in g s L a r g e c a p a c it ie s f o r la r g e - s iz e d b u ild in g s

Main Features

87

Daikin’s indoor unit system offers a large number of connectable indoor units—64! Furthermore, our wide range of indoor units includes 14 types and 79 models to meet the needs of customers.

In d o o r u n its

The previous outdoor unit had a maximum output of 48 HP. The new units have a top output of 54 HP! Three more – a 50 HP model, a 52 HP model, and a 54 HP model, have been introduced, as well as a single 18 HP model that may serve as the main unit in combination solutions. With the introduction of these new models, outdoor unit combinations can be made more compact and flexible to suit large-sized buildings.

By providing a range of horse power levels in 2 HP increments*, Daikin responds flexibly to customer needs.

* Refer to page 37 for combination details.

O u td o o r u n its

48 HP 5 4 HP

Ceiling mounted cassette(Double flow)

Type Capacity RangeCapacity index 20 40 62.5 80 100 125 200 2505031.2525

0.8 HP 1.6 HP 2.5 HP 3.2 HP 4 HP 5 HP 8 HP 10 HP2 HP1.25 HP1 HP

Ceiling mountedcassette (Multi flow)super cassette

FXCQ-M

FXFQ-M

Slim ceilingmounted duct

Ceiling mountedduct

Ceiling suspended

Wall mounted

Floor standing

Concealedfloor standing

Ceiling mountedcassette corner

FXDQ-NAVE(with drain-up pump)

FXDQ-NVET(without drain-up pump)

FXMQ-MA

FXHQ-MA

FXAQ-MA

FXLQ-MA

FXNQ-MA

FXKQ-MA

Ceiling mountedbuilt-in FXSQ-M

FXDQ-PVET(without drain-up pump)

FXDQ-PVE(with drain-up pump)

(900/1,100 mm width type)

(700 mm width type)

• R410A VRV system indoor units are not compatible with the R22 VRV system.Notes:

2 HP increments

Offering a higher capacity of up to 54 HP,responding to the needs of large-sized buildings

* Except for 5 HP 30, 32, 34, 36 HP

38, 40, 42, 44, 46 HP 48, 50, 52, 54 HP

5 HP 8, 10 HP 12, 14, 16, 18 HP

20, 22, 24, 26, 28 HP

VRVIIMA series

New

The latest technology is implemented in the VRVIII system. Surpassing even the VRVII, the new VRVIII responds to more of the needs of our customers that require air-conditioning solutions for large-sized buildings.

Major advances of the VRVIII over the VRVII for large-sized buildings

Ceiling suspendedcassette

Type—

1.6 HP0.8 HP 1.25 HP1 HP

— — — —

Capacity Range

Connection Unit20 4031.2525

BEVQ125MAVE

5 HP

BEVQ100MAVEBEVQ71MAVE

2 HP 4 HP3 HP

— FXUQ71MAV1 FXUQ100MAV1 FXUQ125MAV1

50 12510071Capacity Index

• Indoor units in the 63 class are not available for the above models.• BEV units are necessary for Connection unit series indoor units. Refer to the Engineering Data for details.

Notes:

C o n n e c tio n u n it s e r ie s in d o o r u n its

Page 6: C OOLING O - Premium Serve

Main Features

L a r g e c a p a c it ie s f o r la r g e - s iz e d b u ild in g s L a r g e c a p a c it ie s f o r la r g e - s iz e d b u ild in g s

Conditions of indoor unit connection capacity

109

Piping length is drastically extended! The long piping length provides more design flexibility, which can match even large-sized buildings.

E x te n d e d lo n g p ip in g le n g th

The number of connectable indoor units has been drastically increased from 40 to 64!

A n in c r e a s e d n u m b e r o f c o n n e c ta b le in d o o r u n itsNew

New

New

Connection capacity at maximum is 200%.

C o m b in a tio n r a tio

40 6 4

Increased indoor unit connections Standard system

indoorunits

VRVIIMA series

VRVIIMA series

indoorunits

Refer to page 37 for the maximum number of connectable indoor units.

Maximum number of connectable indoor units

Up toUp to150 m 1 6 5 m

175 m 1 9 0 m

510 m 1 0 0 0 m

Max. equivalentpiping length

Totalpiping length

Level differencebetween the outdoor unitsand the indoor units

Max. actual piping length

50 m 2

p

q

k

First outdoor branch

a i

srhgf

f

edcbFirst indoor branch

ab

Firstindoor branch

Multiple use

Single use

*The rest of indoor units are the same as for single use.

Colours in the diagram above are merely for identifying pipes referenced with symbols such as a .

Notes:* For the FXFQ25 models, maximum connection ratio is 130% for the entire range of outdoor units.

• If the operational capacity of indoor units is more than 130%, low airflow operation is enforced in all the indoor units.

5 0 % —2 0 0 %C onne c tion c a pa c ity

Single outdoor units

Double outdoor units

Triple outdoor units

FXDQ, FXSQ, FXAQ models

Applicable indoor units Other indoorunit models*

200%200%160%130%

1. No special requirements up to 40 m. The maximum actual piping length can be 90 m, or less depending on conditions. Various conditions and requirements have to be met to allow utilisation of 90 m piping length. Be sure to refer to the Engineering Data (the latest version of the VRVIII Engineering Data) for details of these conditions and requirements.

2. 40 m or less if the outdoor unit is below.3. Available on request if the difference in level is between 50 m and 90 m (if the outdoor unit is above).

Maximumallowablelevel difference

Maximumallowablepiping length

Between the outdoor unitsand the indoor units

Between the indoor units

Between the outdoor units (Multiple use)

Between the first indoor branch and the farthest indoor unit

Between the outdoor branch and the last outdoor unit

Total extension length

Refrigerant piping length

15 m or less

90 m or less

5 m or less

90 m or less

q

s

r

r

a+b+c+d+e+f+g+h+i

a+f+g+h+i

f+g+h+i

k+p

165 m or less 190 m or less

1000 m or less

90 m or less*1

10 m or less 13 m or less

Actualpiping length

Equivalentpiping length Example

Level Difference Example

RXQ5P-54P

50 m or less rRXQ5P

RXQ8P-54P

Outdoor Units

3 Available on requestIf the outdoor unit is above.If the outdoor unit is below.

If the outdoor unit is above.If the outdoor unit is below. 40 m or less r

90 m 3

(RXQ8P-54P)

50 m 2

(RXQ5P)

Page 7: C OOLING O - Premium Serve

L a r g e c a p a c it ie s f o r la r g e - s iz e d b u ild in g s

Main Features

L a r g e c a p a c it ie s f o r la r g e - s iz e d b u ild in g s

E a s ie r in s t a lla t io n a n d m a in t e n a n c e

H ig h e x te r n a l s ta tic p r e s s u r e 7 8 . 4 P a ( 8 m m H 2 O )New High-COP types (Energy saving types)

58.8 P a 7 8 . 4 P a

Approx.

3 3 . 3 %increase!

* Refer to page 37 for outdoor combination details.

H PS ingle unit

8

5

10

12

14

16

18

T ota l number of c onnec ted outdoor units

18

2

24

3

30

3

36

3

46

3

S e le c ta b le fr o m tw o ty p e s o f c o m b in a tio n sNew

New

New

A u to m a tic te s t o p e r a tio n

M e m o r y fu n c tio n fo r o p e r a tio n a l d a ta

Normal types (Space saving types)

* Refer to page 37 for outdoor combination details.

8

10

12

14

16

18

8

1

5

5

1

22

2

24

2

26

2

10

1

28

2

12

1

34

2

16

1

30

2

14

1

20

2

32

2

36

2

18

1T ota l number of c onnec ted outdoor units

H PS ingle unit

8

10

12

14

16

18

5

40

3

38

3

42

3

46

3

48

3

44

3

50

3

52

3

54

3T ota l number of c onnec ted outdoor units

H PS ingle unit

Higher external static pressure has been achieved thanks to the fan grilles and the dual DC fans that reduce internal pressure loss. Exceeding the previous 58.8 Pa (6 mm H2O) level, Daikin now offers 78.4 Pa (8 mm H2O) external static pressure by field setting to meet the requirements for installation on each floor, often requested for large-sized buildings.

VRVIIMA series

1211

Single outdoor units Double outdoor units

Triple outdoor units

Triple outdoor unitsDouble outdoor units

H PS ingle unit

5

8

10

12

14

16

18

T ota l number of c onnec ted outdoor units

Triple outdoor units

16

2

26

3

28

3

32

3

34

3

38

3

40

3

42

3

44

3

50

3

48

3

Simply press the test operation button and the unit performs an automatic system check, including wiring, shutoff valves, sensors, and refrigerant volume. The results are returned automatically after the check finishes.

Operating data for the preceding 3 minutes is automatically stored in memory. Should a malfunction occur, this speeds up the process of identifying and fixing the cause of the problem. It also helps in developing measures to eliminate malfunctions.

Page 8: C OOLING O - Premium Serve

A s e n s e o f r e s p o n s ib ilit y E n h a n c e d c o m f o r t

Main Features

1413

O u td o o r u n its d e s ig n e d fo r lo w - n o is e o p e r a tio nH ig h C O P s

It has become essential for air conditioning manufacturers to develop systems that provide high energy savings. We at Daikin have made great efforts in this field, and the newly-developed VRVIII delivers highly efficient performance, contributing to high energy savings.

Outdoor units created with cutting-edge technologies provide quiet operation to increase users’ comfort.

E ffic ie n t c o m p r e s s o r

New high-performance, low-noise scroll compressor operates at a faster rate, reducing start-up time. This helps the unit to bring the room temperature up to the set level quickly.

N ig h ttim e q u ie t o p e r a tio n fu n c tio n

C o m p lia n t w ith th e R o H S D ir e c tiv e *

We have been making efforts to facilitate the transition to using RoHS Directive*-compliant materials for system parts.

L e s s c h a n c e s o f r e fr ig e r a n t le a k a g e

Conventionally, shutoff valve connections are flanged or flared. In the VRVIII system, the connections for all outdoor units are brazed, meaning less chance of refrigerant leakage.

* RoHS DirectiveThe RoHS (Restriction of Hazardous Substances (in electrical and electronic equipment)) Directive is an environmental directive enacted to regulate the use of designated chemical substances (lead, cadmium, hexavalent chromium, mercury, polybrominated biphenyls and polybrominated diphenylether) in electrical equipment. All household products subject to this Directive and sold in Europe from July 1, 2006 are legally bound to comply with the RoHS Directive.

Set on the outdoor PCB. Time of maximum temperature is memorised. The low operating mode will become active 8 hours*2 after the peak temperature in the daytime, and operation will return to normal 10 hours*3 after that. The operation sound level for the night mode can be selected from 55 dB (Step 1), 50 dB (Step 2) and 45 dB (Step 3).(For a single outdoor unit.)

Automatic mode

Operation sound level selectable from 3 steps for the night modeMode 1.

Automatic modeMode 1.

Starting time and ending time can be input. (External control adaptor for outdoor unit, DTA104A61 or DTA104A62, and a subsequently obtained timer are necessary.)

Manual modeMode 2.

Combination of mode 1 and 2 can be used depending on your needs.

Combined modeMode 3.

*1. Determine which mode to select depending on the climatic characteristics of each country.

*2. Initial setting. Can be selected from 6, 8 and 10 hours.*3. Initial setting. Can be selected from 8, 9 and 10 hours.

• This function is available in setting at site.• The relationship of outdoor temperature (load) and time shown in the graph is just an example.

New New

New

New

New

New

We have reached a new level of efficiency, thanks to the new advanced features such as the heat exchanger, the grille and the dual DC fans.

Ac hieving a higher C OP

•Cooling operating conditions: Indoor temp. of 27°CDB, 19.0 °CWB, and outdoor temp. of 35°CDB.•Heating operating conditions: Indoor temp. of 20°CDB, and outdoor temp. of 7°CDB, 6°CWB.

1

16 HP

VRVIIMA series

24 HP

2

3

43.17

4.27

3.47

4.28

Comparison of VRVII and VRVIII

Normal types(Space saving types)

High-COP types(Energy saving types)

(For cooling operation)

Approx.51%* increase!

* Compared to VRV II MA series

2.81 3.

18

The capacity reduction rate differs depending on the operation sound level step selected.

Note:

Peak in the outdoor temperature (For 10 HP, 28 kW outdoor unit)

Capa

city %

8 hrs 10 hrs

Oper

atio

n so

und

dB

50

8:00 12:00 16:00 20:00 0:00 4:00 8:00

50

100

5855

0Load

%

Night mode endsNight mode starts Night mode endsNight mode starts

Night Mode

45

(Initial setting)(Initial setting)

Step 2 max. - 8dB

Step 1 max. - 3dB

Step 3 max. - 13dB

Step 2: 50 dB

Step 1: 55 dB

Step 3: 45 dB

Page 9: C OOLING O - Premium Serve

1615

Control Systems

The same operation modes and settings as with wired remote controllers are possible.

• A light receiving unit for a ceiling-mounted cassette (double-flow, multi-flow) type, ceiling-suspended type and wall-mounted type is mounted into the indoor unit.

The remote controller has centralised its frequently used operation selectors and switches (on/off, operation mode, temperature setting and airflow volume), making itself suitable for use in hotel rooms or conference rooms.The exposed type remote controller is fitted with a thermostat sensor.

Signal receiver unit(Separate type)

Wireless remote controller

The concealed-type remote controller smartly fits into a night table or console panel in a hotel room.

Exposed type(BRC2C51)

Concealed type(For hotel use)

(BRC3A61)

Wireless remote controller (Optional)

Simple remote controller (Optional)

Signal receiver unit(Installed type)

Signal receiving unit can be installed on the panel ex. Ceiling mounted cassette (multi-flow) type

Wired remote controller

Wired remote controller with weekly schedule timer

Wireless remote controller(Installed signal receiver unit)

Wireless remote controller(Separate type signal receiver unit)

Simple remote controller(Exposed type)

Simple remote controller(Concealed type: for Hotel use)

FXCQ FXFQ FXKQ FXSQ FXMQ FXHQ FXAQ FXL(N)Q FXUQFXDQ

I n div idu a l C o n t r o l S y s t e m s

*Refer to page 50 for the name of each model.

Easier to read because LCD screen is larger.Digital display lets you set temperature in 1°C units.Lets you individually programme by timer the respective times for operation start and stop within a maximum of 72 hours.Equipped with a thermostat sensor in the remote controller that makes possible more comfortable room temperature control.Constantly monitors malfunctions in the system for a min. of 40 items, and is equipped with a "self-diagnosis function" that lets you know by

message immediately when a malfunction occurs.Lets you carry out various field settings by remote controller.Enables you to select the ventilation mode and the volume of the HRV.The rubber switch and the oil-resisting resin casing have been adopted for durability.

* When the auto-swing function is not available, the message, THIS FUNCTION IS NOT AVAILABLE is displayed when the wind direction adjustment button is pressed.

Wired remote controller (Optional)

BRC1C62

Wired remote controller with weekly schedule timer (Optional)

BRC1D61

24-hour clock function (1-hour backup for power failures)

Includes ventilation mode and airflow rate switching, the main functions of HRV series.

Programming function for each day of week.

Scheduling possible of start/stop and temperature limit (5 settings/day)

Programming can be enabled or disabled.

Copy function for programmed schedules.

Adds advanced functions to those of the above wired remote controller.

Notes: 1. Standard remote controllers (BRC1C62) not required. 2. If the BRC1D61 is connected to the centralised remote controller, the schedule function is not available.

Outdoor unit

Indoor unit

Forced OFF input

Remote controllerRemote controller

Remote controllerRemote controller

Remote controllerRemote controller

Remote controller

Remote controller

HRV

The indoor unit can be connected by the two remote controller, for example one in the room and the other one in the control room, which can control the operation of indoor unit freely.(The last command has a priority.) Of course, the group control by two remote controller is also possible.

Control by two remote controller

The system can be expanded to add several controllers, such as BMS, Forced OFF input and etc.

Expansion of system control

In all the series of VRV, Cool/Heat changeover in the same refrigerant circuit can be changed by the remote controller of the indoor unit.

Control of Cool/Heat changeover

One remote controller can control the operation of max.16 indoor units at the same time.

Group control

Equipment related to the central control

1 2 3

The wiring of remote controller can be extended to max. 500m and it is possible to install the remote controllers for the different indoor units in one place.

Remote control

The operation of HRV can be controlled by the remote controller of the indoor unit. Of course, the remote controller can display the time to clean the filter.

Control for the combined operation

4

4

3

2

1 Wide variation of remote controllers for indoor unitsWide variation of remote controllers for indoor units

Wide variation of remote controllers for indoor unitsThe wired remote controller supports a wide range of control functions

Page 10: C OOLING O - Premium Serve

Control Systems

1817

Note: 1. Installation box for adaptor must be procured on site.

Central remote controller (Optional)

64 groups (zones) of indoor units can be controlled individually same as LCD Remote controller.

Max. 64 groups (128 indoor units controllable)Max. 128 groups (128 indoor units) are controllable by using 2 central remote controllers, which can control from 2 different places. Zone controlMalfunction code displayMax. wiring length 1,000 m (Total: 2,000 m)Combination with Unified ON/OFF controller, schedule timer and BMS systemAirflow volume and direction can be controlled individually for indoor units in each group operation.Ventilation volume and mode can be controlled for Heat Reclaim Ventilation (HRV).Up to 4 Operation/Stop pairs can be set per day by connecting a schedule timer.

Unified ON/OFF controller (Optional)

16 groups of indoor units can be operated simultaneously/individually.

Max. 16 groups (128 indoor units) controllable2 remote controllers can be used to control from 2 different places.Operating status indication (Normal operation, Alarm)Centralised control indicationMax. wiring length 1,000 m (Total: 2,000 m)Compact size casing (Thickness: 16 mm)Combination with Central Remote controller, Schedule timer and BMS system

Schedule timer (Optional)

Max.128 indoor units can be operated as programmed schedule.

Max. 128 indoor units controllableWhen used in combination with a central remote controller, a maximum of 8 weekly schedule patterns can be set, while the central controller can be used to select desired zones. Up to 2 Operation/Stop pairs can be set per day.Max. 48 hours back up power supplyMax. wiring length 1,000 m (Total: 2,000 m)Compact size casing (Thickness: 16 mm)Combination with Central Remote controller, Unified ON/OFF controller and BMS system

Up to 64 groups of indoor units (128 units) can be centrally controlled.

Optional controllers for centralised control can be combined freely, and system can be designed in accordance with building scale and purpose.

System integration with various air-conditioning peripheral equipment such as HRV (Heat Reclaim Ventilation) is easy.

Wiring can be run up to a total length of 2 km, and adapts easily to large-scale system expansion.

Part name Model No. Function

Unification adaptor for computerised control DCS302A52

Interface between the central monitoring board and central control units. Combined with the central remote controller, this adaptor enables the central monitoring board to centralise such functions as the on/off control, operation status monitoring, and normal/malfunction monitoring.(*1)

Interface adaptor for SkyAir series DTA102A52

Wiring adaptor for other air-conditioner DTA103A51

DTA107A55

Adaptors required to connect products other than those of the VRV System to the high-speed DIII-NET communication system adopted for the VRV System.

* To use any of the above optional controllers, an appropriate adaptor must be installed on the product unit to be controlled.

Central control adaptor kitFor UAT(Y)-K(A), FD-K

For SkyAir, FD(Y)M-FA, FDYB-KA, FDY-KA, FVY(P)J-A, FXUQ-MA

For air conditioners other than mentioned above.

C e n t r a l is e d C o n t r o l S y s t e m s

DCS302CA61

DCS301BA61

DST301BA61

Central control adaptor kit (DTA107A55).

Central remote controller(DCS302CA61)

Up to 2 units connectable

Unified on/off controller(DCS301BA61)

Connection of up to 8 unitspossible

Schedule timer (DST301BA61)1 unit connection possible ; 8 weekly schedule control patterns possible

Forced shut-down input

Independent and centralised control of HRV is possible.

Unification adaptor for computerised control * (DCS302A52)

Interlink Building Management System (host computer monitor panel) also possible

6 cores 7 cores max.

Address setting of central control can be performed from the remote controller.

Group control of up to 16 units is possible (group control via automatic address setting)

System without remote control is also available.

Interface adaptor for SkyAir series (built-in indoor unit) (DTA102A52)

Connectable number of centralised control equipment

Central remotecontroller 2 units

Unified on /offcontroller 8 units

Schedule timer 1 unit

Wiring adaptorfor other air-conditioners (DTA103A51)

For more details, please refer to the Engineering Data.

Outdoor-air processing unit can be connected.

• Certain indoor units limit the functions of some control systems.

Interface adaptors (Optional)

Page 11: C OOLING O - Premium Serve

Control Systems

2019

A dv a n c e d c o n t r o l s y s t e m s

Contact signal

Ai unit(DAM101A51)

Fan

Daikin CentralAir Conditioning System

Local monitoring & control

Multi-PC Ethernet

Sub PC

Fire alarm

D -NET

D -NET

D -NET

D -NET

Wiring adaptor required for connection with other equipment not compatible with D -NET

Via internet

Intranet/Internet

Web AccessWeb Access

Malfunction reportby E-mail

HRV

VRV System

Centralised control system for easy provision of effective control and monitoring of VRV system functions

*1Air ConditioningNetwork Service System(Optional Maintenance Service)

Dio unit(DEC102A51)

S pe c ia l F u n c t io n s

• Features control and monitoring functions for central A/C products and an Air Conditioning Network Service function.

• Using an external contact via DIII-NET, monitors and controls equipment such as lighting, fans, or building security systems.

Interfacing requirements vary depending on model, and some systems may not be suitable. Please contact your distributor for details.• Information on these systems is preliminary only. Please contact Daikin for formal information on the products.

Floor visual navigationGraphical reportMulti-PC accessAnalogue interlockAutomatic heat/cool change-overTemperature limitationSliding temperature <Optional (DAM101A51) unit required>Energy saving function (ECO mode. Power limit control) (Optional)Air Conditioning Network Service System (Optional Maintenance Service)

N e w F e a t u r e s

New

Light Pump

*2

Monitor and control from the remote site by Web browser (Optional)PPD data can be managed from the remote site by Web browser (Optional)Send malfunction report through the Internet by E-mail (Optional)Compliant with the RoHS Directive (DAM602B51/52)(refer to page 13 for details.)

DAM602B51/52

Page 12: C OOLING O - Premium Serve

New

Control Systems

2221

A dv a n c e d c o n t r o l s y s t e m s

Ethernet

Local Controller

Please contact Daikin for compatibility with BMS system

SecurityPower supply facility

Fire alarm

Lift Pump Lighting...etc

BMS

HRV

VRV System

Integrated control systems that recognise the trend of open control systems

Compatibility with BMS enhanced by utilising the international communication standards, BACnet® or LONWORKS®.

XIF file for confirming of specifications of the units.Connectable up to 10 outdoor units and 64 indoor unit groups.

Conformance class 3 (ASHRAE 135–1995)Standard BACnet® Device B-ASC (ASHRAE 135–2001)PPD data (Optional Di board is required.)ISO 16484-5 (Does not support IEEE 802.3 protocol for BACnet®)Compliant with the RoHS Directive (refer to page 13 for details.)Up to 40 outdoor units and 256 indoor unit groups on one gateway. (optional adapter)

DMS504B51 Interface for use in LONWORKS®

DMS502B51 Interface for use in BACnet®

Local dealers

I/F unit*5Automatic data transfer

Mainfunction informationby E-mail

INTERNET

*1. There are restrictions in applicable areas and release times, therefore please consult us separately for details.

*2. Model name varies upon the system size.

*3. BACnet® is a registered trademark of American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE).

*4. LONWORKS® is a registered trade mark of Echelon Corporation.

*5. For an I/F unit, one of the following can be selected: L oc al C ontroller, intelligent touch Controller, or intelligent Manager III.

*6. Ethernet is a registered trademark of Xerox Corporation.

*7. Refer to the Options page for the name of each model.

ACC center

Maintenance services that boost profits and customer satisfactionAir Conditioning Network Service System

24 hour on-line diagnostic system Energy saving and extention of aircon operating life Maintenance management via A /C network service system reports Reliable service at shortest lead time

DMS502B51(Interface for use in BACnet®)

DMS504B51(Interface for use in LONWORKS®)

Communication functions in the user-friendly icon-based multilingual controller simplify centralised control of the VRV system.

Colour LCD touch panel icon displaySmall manageable size Simplified engineeringMulti language (English, French, Italian, German, Spanish and Chinese)Yearly scheduleP.P.D. (Power Proportinal Distribution function) (Optional)Temperature limitationHistory of 500 actionsAir Conditioning Network Service System (Optional Maintenance Service)Simple Interlock Function

Support for centralised control from elsewhere using a PC with a Web browser (Optional)

Sending of e-mail alerts to a specified address when malfunctions occur (Optional)

Built-in modem for connecting to Airnet Service System (Optional)

Built-in Ethernet port for connecting to the Internet or an intranet

Management of facilities / equipment other than A/C units(Compatible with Dio unit and Di unit)

Doubling of number of control points by adding a D -NET Plus Adapter (Optional)Special

Function 1Special

Function 1

SpecialFunction 2

SpecialFunction 2

SpecialFunction 3

SpecialFunction 3

SpecialFunction 4

SpecialFunction 4

SpecialFunction 5

SpecialFunction 5

SpecialFunction 6

SpecialFunction 6

SpecialFunction 7

SpecialFunction 7 Simple Interlock Function

S pe c ia l F u n c t io n s

ACC center• Air Conditioning Network Service System

Forced OFF from the fire alarm

Pi Port

• Connection to power consumption metre when using power proportional distribution function. (Optional)

DIII-NETPlus Adapter(option)(DCS601A52)

Number of indoor unit expanded from 64 to 128.

Indoor Unit

RS-232C

Control pump, lighting

Monitoring of roomenter/exit sign

Simple Interlock Function

Public phone line

Air Conditioning Network Service System modem for connections

• CSV output of power proportional distribution results (Optional)

PCMCIAFlash

Memory

Mobile PhoneTrouble reports

Forced OFF contact input

HRV

D -NET

SpecialFunction 6

SpecialFunction 1

Remote monitoring and control

SpecialFunction 5

SpecialFunction 3

SpecialFunction 2

SpecialFunction 4

SpecialFunction 6

SpecialFunction 1

SpecialFunction 3Special

Function 5

SpecialFunction 3

SpecialFunction 2

SpecialFunction 4

SpecialFunction 6

SpecialFunction 7

SpecialFunction 7

SpecialFunction 1

SpecialFunction 3Special

Function 5

SpecialFunction 3

SpecialFunction 2

SpecialFunction 4

Trouble reports

Unification adaptorfor computerised control

[DCS302A52]

Unified ON/OFF andstatus monitoring from the central monitoring panel

DCS601C51

E-mail

BACnet® LONWORKS®Interface for and

Dio unit(DEC102A51)

Di unit(DEC101A51)

Page 13: C OOLING O - Premium Serve

2423

DAM602B51/52

BMS(Field Supply)

Wiring adaptorfor electrical appendices(KRP2A61/62/53)

Telephone Line

Interface Adaptor for Sky Air Series(DTA102A52)

Central Control Adaptor Kit(DTA107A55)

Central RemoteController(DCS302CA61)

(DCS601C51)

Schedule Timer(DST301BA61)

Unified ON/OFFController(DCS301BA61)

Parallel Interface(DPF201A51/52/53)

Unification adaptorfor computerised control(DCS302A52)

Air-conditioner Data Management System backed by the Building Multi Communication Line DIII-NET. Air-conditioner data can be directly transferred without interface for 100% data management.

DIII-NET Line

BACnet®/Ethernet or LONWORKS®

Network Communication Line

Contact Signal Line

Caution: Limitation may apply to some models and functions. Please contact your local sales office for details. Consultation is necessary before employing this control system. Please contact your local sales office before making a purchase.

Air Conditioning Network Service System(There are restrictions in applicable areas and release times, therefore please consult us separately for details.)(Optional Maintenance Service)

Control /Connection Interface

Building Control System

Interface for use in BACnet®(DMS502B51)

Interface for use in LONWORKS®

(DMS504B51)

ACC Center

Di unit (DEC101A51)Dio unit (DEC102A51) Building services equipment

∑ Electrical equipment∑ Supply water and drainage equipment∑ Automatic fire alarm∑ Parking equipment∑ Lift∑ Ventilation equipment∑ Lighting∑ Crime and fire prevention equipment

I n t e g r a t e d B u i ld in g M o n it o r in g S y s t e m

Controllers for Centralised Control

The high speed transmission of DIII-NET enables more advanced control of the VRV system, providing you with enhanced comfort.

D -NET(High Speed Multiple

Transmission)

DIII-NET, Daikin’s unique high speed multiple transmission system, links air conditioners and various other building equipment—in accordance with applications, scale and conditions—and transmits vast amounts of information between them.

Note: BACnet® is a registered trademark of American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE). LONWORKS® is a registered trademark of Echelon Corporation. Ethernet is a registered trademark of Xerox Corporation.

Control Systems

The DIII-NET system provides for:∑ Close control and monitoring by integrating a wide variety of air-conditioners in the

entire building.∑ Saving the in-building cabling using non-polar, two-wire cables. Easier wiring work with

tremendously fewer wiring errors.∑ Additional setups readily up and running. An extendable cabling up to 2 km in total.∑ Different control equipment flexibly joined in the system for hierarchical risk

diversification.∑ Daikin's total heat exchangers and other devices under integral control.

VRV

HRV unit

SkyAir

Packaged Air-conditioner

* No adaptor is required for the FHYCP-DVE and FAY(P)71L.

VRV

Page 14: C OOLING O - Premium Serve

Indoor Units Line Up

Ceiling mounted cassette (double-flow) type

2625

Thin, lightweight, and easy to install in narrow ceiling spaces

FXCQ20M/FXCQ25M/FXCQ32M

FXCQ40M/FXCQ50M/FXCQ63M

FXCQ80M/FXCQ125M

Ceiling MountedCassette(Double-flow)

Type

Ceiling MountedCassette(Multi-flow)Super Cassette

Ceiling MountedCassette Corner

Wall Mounted

Floor Standing

Concealed FloorStanding

FXCQ-MVE

FXFQ-MVE

FXHQ-MAVE

Capacity rangeCapacity index

FXKQ-MAVE

FXLQ-MAVE

FXNQ-MAVE

FXMQ-MAVE

Model name 20 25 31.25 40 50 62.5 80 100 125 200 2500.8 HP 1 HP 1.25 HP 1.6 HP 2 HP 2.5 HP 3.2 HP 4 HP 5 HP 8 HP 10 HP

FXDQ-NAVE(900/1,100 mm

width type)

FXDQ-NVET(900/1,100 mm

width type)

with drain-up pump

without drain-up pump

FXSQ-MVECeiling MountedBuilt-in

Ceiling Suspended

Ceiling Mounted Duct

FXAQ-MAVE

Ceiling SuspendedCassette

Type—

1.6 HP0.8 HP 1.25 HP1 HP

FXUQ-MAV1

Model name 20 4031.2525BEVQ125MAVE

5 HP

BEVQ100MAVEBEVQ71MAVE

2 HP 4 HP3 HP50 12510071

• Indoor units in the 63 class are not available for the above models.• BEV units are necessary for Connection unit series indoor units. Refer to the Engineering Data for details.

Notes:

• R410A VRV system indoor units are not compatible with the R22 VRV system.Note:

Connection unit series indoor unitsCapacity Range

Connection UnitCapacity Index

Slim Ceiling Mounted Duct

FXDQ-PVE(700 mm

width type)

FXDQ-PVET(700 mm

width type)

with drain-up pump

without drain-up pump

600 mm

Class 20

32/27

25/32

34/28

63

37/32

40/50

34/29

80

39/34

125

44/38

34/29 36/30 39/3437/32 41/36 46/40

(dB(A))

350mm

The thin unit (only 350 mm high) can be installed in a ceiling space as narrow as 355 mm. All models feature a compact design with a depth of only 600 mm.

(When a high-efficiency filter is attached, the unit's height is 400mm.)

Low operating sound

Designed with higher air flow suitable for high ceiling application up to 3 metres.

Providing 2 different settings of standard and ceiling soiling prevention, the auto swing mechanism realises even distribution of airflow and room temperature.

Two types of optional high-efficiency filter are available (65% and 95% NBS).

A long-life filter (maintenance free up to one year) is equipped as standard accessory.

Drain-up pump is equipped as standard accessory with 600 mm lift. Major maintenance work can be performed by

removing the panel. A flat-type suction grille and a detachable blade make cleaning easy.

220V

240VOperating

Sound (H/L)

Page 15: C OOLING O - Premium Serve

Indoor Units Line Up

Ceiling mounted cassette corner type

2827

Slim design for flexible installation

Ceiling mounted cassette (multi-flow) type

Compact, quiet and easy-to-install Super Cassette type

Regardless of their difference in capacity, all indoor units feature the same panel size and design, in consideration of harmonised interior decor.

The FXFQ25M-80M are thin models(246 mm) which can be installed in narrow false ceilings of at least 265 mm depth.

(220 V-240 V)(dB(A))

Single branch– 8 patterns

2 branches–2 patterns

Number of discharge outlets usedFXFQ25M-80M FXFQ100M-125M

4-way air discharge

3-way air discharge

2-way air discharge

4-way air discharge

3-way air discharge

2-way air discharge

Ceilingheight

Standard 2.7 m3.0 m3.5 m

3.0 m3.3 m3.5 m

3.5 m3.8 m

3.2 m3.6 m4.2 m

3.6 m4.0 m4.2 m

4.2 m4.2 m

–High ceilingHigh ceiling

Note: Set standard 4-way discharge when shipped.High ceiling types and will be set for remote control operation.1 2

12

40˚40˚10˚ 10˚

Pattern

2 Draft Prevention setting

Pattern

1 Standard setting

7 discharge patterns in 2 to 4 directions can be selected to suit the requirements of installation site or the shape of the room.The number of installation method using ducts has increased as shown below.

Pipinglocation

Has been set to standard setting at time of shipment. This can be changed using the remote control.

Closed

Branched

Pipinglocation

ClosedBranched

25˚ 25˚

60˚ 60˚35˚35˚

65˚ 65˚

Pattern

3 Setting to prevent soiling of ceiling

750mm

Because of the light weight, suspension is easy.Low operating sound

Installing the fresh air intake is easy using the optional kit which requires no special chambers.A long-life filter (maintenance free up to two years) is equipped as a standard accessory.

Provided with high lift drain water lift-up mechanism. (Increased lift of drain pipe up to 750 mm from the ceiling.)

Note: Operating sound may increase more than that when using with 3-way discharge or 2-way discharge, or when using together with a optional kit. : The values of Hi mode Sound level represent those during cooling operation. Those during heating operation are shown in brackets for two models only.

42(43) /36

125

39/33

100

36/31

80

33(34) /28

63

32/27

50

31/27

40

30/27

32

30/27

25Operating

sound (H/L)

Class

3

32˚C 30˚C28˚C 26˚C 24˚C

22˚C

20˚C

2

1

0 1 2 3 4 5 6 (m)

(m)

Panel spac er

20 mm

Min.195 mm

Main body

Air disc harge grille (option)

Set for front discharge using a suspended ceiling.

Downward discharge is shut off and air is blown straight out (front discharge).

Compliant with the RoHS Directive (refer to page 13 for details.)

Single-flow type allows effective air discharge from corner or from drop-ceiling. Front discharge is possible with a air

discharge unit (optional), which allows the installation in the drop-ceiling or sagging wall.

Slim body needs only 220 mm space above the ceiling. If you use a panel spacer (optional), the unit can be installed in the min. space of 195 mm.

A long-life filter (maintenance free up to one year) is equipped as standard accessory.

Providing 3 different settings of standard, draft prevention and ceiling soiling prevention, the auto swing mechanism realises even distribution of airflow and room temperature.

500 mm

Drain-up pump is equipped as standard accessory with 500 mm lift.

Main body

Downward disc harge

Air disc harge grille (option)

FXFQ25M/FXFQ32M/FXFQ40M

FXFQ50M/FXFQ63M/FXFQ80M

FXFQ100M/FXFQ125M

FXKQ25MA/FXKQ32MA

FXKQ40MA/FXKQ63MA

Can also be installed in high ceilings.

There are 3 patterns in auto swing operation

Page 16: C OOLING O - Premium Serve

Ceiling mounted built-in type

3029

Highly flexible for various application

FXSQ20M/FXSQ25M/FXSQ32M

FXSQ40M/FXSQ50M/FXSQ63M

FXSQ80M/FXSQ100M/FXSQ125M

Slim ceiling mounted duct type

Slim design, quietness and static pressure switching

FXDQ20N(A)/FXDQ25N(A)/FXDQ32N(A)

FXDQ40N(A)/FXDQ50N(A)/FXDQ63N(A)FXDQ20P/FXDQ25P/FXDQ32P

External static pressure selectable by remote controller switching make this indoor unit a very comfortable and flexible model.10 Pa-30 Pa/factory set: 10 Pa for FXDQ-P models.15 Pa-44 Pa/factory set: 15 Pa for FXDQ-N(A) models.

Only 200 mm in height, this model can be installed in rooms with as little as 240 mm depth between the drop-ceiling and ceiling slab.

Only 700 mm in width and 23 kg in weight, this model is suitable to install in limited spaces like drop-ceilings in hotels.

Low operating sound

36/32

63

35/31

50

34/30

40

33/29

32

33/29

25

33/29

20Operating

sound (H/L)

Class(dB(A))

The values of operation sound level represent those for rear-suction operation.Sound level values for bottom-suction operation can be obtained by adding 5 dB. Values are based on the following conditions:FXDQ-P: external static pressure of 10 Pa; FXDQ-N(A): external static pressure of 15 Pa.

1,100 mm in width for the FXDQ63N(A) model.

200mm900 mm

Suction grille*AIR

AIR

Discharge grille*

Air filterSuspension bolt*

240 mm

*: To be obtained locally

750 mm

Ceiling

FXDQ-P and FXDQ-N(A) models are available in two types to suit different installation conditionsFXDQ-PVE, FXDQ-NAVE: with a drain-up pump (750 mm lift) as a standard accessoryFXDQ-P(N)VET: without a drain-up pump

Only 700 mm200 mm

Great for hotel use!

250 mm

Min.350 mm

Highly flexible installation is possible with a complete line-up of optional kits to satisfy various needs, such as the design concept, interior decoration and so on.

The unit can be installed, if there is a space of 350 mm above ceiling. (when suction panel is used.)

Drain-up pump is equipped as standard accessory with 250 mm lift.

High external static pressure allows the use of even flexible ducts of various length.

Low operating sound

Two types of optional high-efficiency filter are available (65% and 95% NBS).

A long-life filter (maintenance free up to one year) is equipped as standard accessory.

37/32

39/34Operating

Sound (H/L)

20 25

37/32

32

38/32

40

38/32

50

41/36

63

42/35

80

43/37

100

43/37

125

46/41

39/34 40/34 40/34 43/38 44/37 45/39 45/39 48/43

(dB(A))

Class

Standard

With duct (case 1)

With duct (case 2)

Cassette style (standard filter)

Cassette style (high efficiency filter)

Long-life filter

Long-life filter

Air suc tion c anvas bellows

Air suc tion panel

Air suc tion panel

Ac c ess panel Ac c ess panel

Ac c ess panel Air suc tion c anvas bellows

Ceiling returnLong-life filter

Long-life filter

S c reening door

S c reening door

High effic ienc yfilter

220V

240V

Installation examples ( Optional parts)

Indoor Units Line Up

Compliant with the RoHS Directive *(refer to page 13 for details.)* For FXDQ-PVE and FXDQ-NAVE models only.

Suited to use in drop-ceilings!

Page 17: C OOLING O - Premium Serve

Ceiling suspended type

3231

Slim body with quiet and wide air flow

Ceiling mounted duct type

High static pressure allows flexible duct design

Built-in Drain Pump (optional)Housing the drain pump inside the unit reduces the space required for installation.

More than 150 Pa of external static pressure

Compliant with the RoHS Directive (refer to page 13 for details.)

Compliant with the RoHS Directive (refer to page 13 for details.)

High external static pressure allows extensive duct work for flexible applications.

Optional accessories include a drain-up kit, high-efficiency filters (65% and 95% NBS) and a long-life filter (maintenance free up to 1 year).

Full line-up of 8 models from 40 to 250 type.

Indoor unit

Min450mm390mm

Indoor unit

Min530 mm470 mm

Without drain

Indoor unit

470 mm

0~250mm

222 mm

Without drain With drain

Simplified Static Pressure ControlExternal static pressure can be easily adjusted using a change-over switch inside the electrical box to meet the resistance in the duct system.

Drain-up pump is equipped as optional ac c essory with 750 mm

750mm

120mm

Adoption of newly designed QUIET STREAM FAN

Drain-up kit (optional) c an be eas ily inc orporated.

E asy-to-c lean flat des ign

Maintenanc e is eas ier bec ause everything c an be performed from below the unit.

Non-dew Flap with no implanted bris tles

Class

Operating sound (H/L)

32

36/31

63

39/34

100

45/37

(220V-240V)(dB(A))Low operating sound

Uses the quiet s tream fan and many more advanc ed tec hnologies .

S ound absorptionmember

Turbulent flow is produc ed

S traightening vane

Quiet s tream fan

Installation is easy

Maintenance is easy

Drain-up kit(built ins ide main unit)

600 mm

B ristle-free Flap minimises c ontamination and makes c leaning s impler.

Non-dew Flap

100°New model

Wide air discharge openings produce a spreading 100° air flow.

A long-life filter (maintenanc e free up to one year) is equipped as s tandard

FXMQ200MA/FXMQ250MA

FXMQ40MA/FXMQ50MA

FXMQ63MA/FXMQ80MA

FXMQ100MA/FXMQ125MA

FXHQ32MA/FXHQ63MA

FXHQ100MA

Indoor Units Line Up

Compliant with the RoHS Directive (refer to page 13 for details.)

Page 18: C OOLING O - Premium Serve

Floor standing type

3433

Perfect unit for perimeter zone air conditioning

Wall mounted type

Sophisticated design and compact casing harmonised with your interior décor

Drain pan and air filter can be kept clean by mildew-proof polystyrene.

Compact and stylish design that does not detract from the décor of the room.

Drain-up kit

1,000mm

Height of drain-up

Indoor unit

Drain-pump kit is available as optional accessory, which lifts the drain 1,000 mm from the bottom of the unit.

Auto-swing realises efficiency of air distribution. The louver closes automatically when the unit stops.

5 steps of discharge angle can be set by remote controller.

Washable grille, the front grille can be easily removed for washing.

Discharge angle is automatically set at the same angle as the previous operation when restarting. (Initial setting; 10˚ for cooling and 70˚ for heating)

1,050 mm

For 50, 63 Class–70 mm

–200 mm

290

mm

More compact when compared with previous model. (50, 63 class)

Drastic 10 kg weight reduc tion from 24 kg to 14 kg.Volume reduc ed by 22%. S pac e savings of up to 47%.

Flexible installation.Drain pipe c an be fitted to from either left or right s ides .

Low operating sound

46/39

63

42/36

50

39/34

40

37/29

32

36/29

25

35/29

20Operating

sound (H/L)

Class(220V-240V)(dB(A))

Wall hanging Floor installation

Floor standing types can be hung on the wall for easier cleaning. Running the piping from the back allows the unit to be hung on walls. Cleaning under the unit, where dust tends to accumulate, is considerably easier.

A long-life filter (maintenance free up to one year) is equipped as standard accessory.

Compliant with the RoHS Directive (refer to page 13 for details.)

The adoption of a fibre-less discharge grille featuring an original design to prevent condensation also helps prevent staining and makes cleaning easier.

Concealed floor standing type

Perfect unit to be concealed in the skirting-wall of perimeter

C onnec ting port

R efrigerant piping

Applies also to floor standing type (FXNQ-MA).

The unit is concealed in skirting-wall of perimeter, that enables to create high class interior design.

Compliant with the RoHS Directive (refer to page 13 for details.)

The connecting port faces downward, greatly facilitating on-site piping work.

A long-life filter (maintenance free up to one year) is equipped as standard accessory.

FXAQ20MA/FXAQ25MA

FXAQ32MA/FXAQ40MA

FXAQ50MA/FXAQ63MA

FXNQ20MA/FXNQ25MA

FXNQ32MA/FXNQ40MA

FXNQ50MA/FXNQ63MA

Indoor Units Line Up

Compliant with the RoHS Directive (refer to page 13 for details.)

FXLQ20MA/FXLQ25MA

FXLQ32MA/FXLQ40MA

FXLQ50MA/FXLQ63MA

Page 19: C OOLING O - Premium Serve

3635

Ceiling suspended cassette type

New

New

• Between 12 (5 HP) and up to 64 (54 HP) indoor units in a single refrigerant piping circuit can be individually controlled in minimum increments of 2.2 kW (0.8 HP). Facilities from small to large can be accommodated with the lineup of 5–54 HP models. The units are superbly compact, so less installation space is required.

• Compliant with the RoHS Directive (refer to page 13 for details.)

Normal types (Space saving types)

• High-COP type outdoor units offer highly efficient performance, contributing to energy savings, while a lineup of 16–50 HP models extends the range of applications.

• Compliant with the RoHS Directive (refer to page 13 for details.)

High-COP types (Energy saving types)

Series5 HP

Capacity range8 HP 10 HP 12 HP 14 HP 16 HP 18 HP 20 HP 22 HP 24 HP 26 HP 28 HP 30 HP 32 HP 34 HP 36 HP 38 HP 42 HP 44 HP 46 HP 48 HP40 HP

Series Line Up

50 HP 52 HP 54 HP

Coolingonlytype

Normal types

High-COP types — — — — — — — — —

30, 32, 34, 36 HP 38, 40, 42, 44, 46 HP 48, 50, 52, 54 HP

5 HP 8, 10 HP 12, 14, 16, 18 HP 20, 22, 24, 26, 28 HP

RXQ20PRXQ22PRXQ24PRXQ26PRXQ28P

16, 18 HP

RXQ16PHRXQ18PH

RXQ12PRXQ14PRXQ16PRXQ18P

RXQ8PRXQ10P

RXQ5P

RXQ30PRXQ32PRXQ34PRXQ36P

24, 26 HP

RXQ24PHRXQ26PH

RXQ38PRXQ40PRXQ42PRXQ44PRXQ46P

RXQ48PRXQ50PRXQ52PRXQ54P

28, 30 HP

RXQ28PHRXQ30PH

32, 34 HP

RXQ32PHRXQ34PH

36, 38, 40, 42, 44, 46, 48, 50 HP

RXQ36PHRXQ38PHRXQ40PHRXQ42PH

RXQ44PHRXQ46PHRXQ48PHRXQ50PH

FXUQ71MAV1/FXUQ100MAV1

FXUQ125MAV1

Connection unit

Indoor Units Line Up (Connection unit series indoor units) Outdoor Units Line Up

C o o l in g o n ly t y pe

NE W

This ultra-thin indoor unit achievesoptimum air distribution, and can be installed

without the need for ceiling cavity.

Connection unit is the device for connecting above indoor units to VRV III.

Depending on installation site requirements or room conditions, 2-way, 3-way and 4-way discharge patterns are available.

Compliant with the RoHS Directive(refer to page 13 for details.)

Compliant with the RoHS Directive (refer to page 13 for details.)

4-way air flowfrom the centre of the store.

The 3-way air flow can distributecomfortable air throughout the room.

Only one unit is needed to distribute comfortable airthroughout an L-shaped store.

BEVQ-MAVE

Connection unit for indoor unit

Indoor unitPiping length*1

Indoor unit

R emote c ontroller

S uper wiring ( DIII-NE T )

S ingle-phase 220-240 Vpower supply

Refrigerant piping layout External wiring layout

Notes:G as pipeLiquid

pipe

ModelMaximum piping lengthbetween the BEV unitand the indoor units.

FXUQ-MAV1 5 m

*1

• When connecting centralised-control device, it is necessary to install an interface adaptor for an indoor unit (DTA102A52).

• Connection unit BEVQ-MA is necessary for each indoor unit.

• The refrigerant piping height difference between the indoor units and the BEV unit must be within 4 m.

• The BEV unit must be installed within a maximum height difference between indoor units of 15 m.

• Branching of the refrigerant piping is not possible downstream of the BEV unit.

VR V series outdoor unit

Page 20: C OOLING O - Premium Serve

3837

INDOOR UNITSMaximum number of

connectable indoor units*Total capacity index of

connectable indoor units*HP Combination

RXQ5PRXQ8P

RXQ10PRXQ12PRXQ14PRXQ16PRXQ18P

RXQ8P + RXQ12PRXQ10P + RXQ12PRXQ8P + RXQ16PRXQ8P + RXQ18P

RXQ10P + RXQ18PRXQ12P + RXQ18P

RXQ16P x 2RXQ16P + RXQ18P

RXQ18P x 2RXQ8P + RXQ12P + RXQ18P

RXQ8P + RXQ16P x 2RXQ8P + RXQ16P + RXQ18P

RXQ8P + RXQ18P x 2RXQ10P + RXQ18P x 2RXQ12P + RXQ18P x 2

62.5 to 162.5 (250)100 to 260 (400)125 to 325 (500)150 to 390 (600)175 to 455 (700)200 to 520 (800)225 to 585 (900)250 to 650 (800)275 to 715 (880)300 to 780 (960)

325 to 845 (1,040)350 to 910 (1,120)375 to 975 (1,200)

400 to 1,040 (1,280)425 to 1,105 (1,360)450 to 1,170 (1,440)475 to 1,235 (1,235)500 to 1,300 (1,300)525 to 1,365 (1,365)550 to 1,430 (1,430)575 to 1,495 (1,495)600 to 1,560 (1,560)

Model name

RXQ5PRXQ8P

RXQ10PRXQ12PRXQ14PRXQ16PRXQ18PRXQ20PRXQ22PRXQ24PRXQ26PRXQ28PRXQ30PRXQ32PRXQ34PRXQ36PRXQ38PRXQ40PRXQ42PRXQ44PRXQ46PRXQ48P

5 HP8 HP

10 HP12 HP14 HP16 HP18 HP20 HP22 HP24 HP26 HP28 HP30 HP32 HP34 HP36 HP38 HP40 HP42 HP44 HP46 HP48 HP

8 (12)13 (20)16 (25)19 (30)23 (35)26 (40)29 (45)32 (40)35 (44)39 (48)42 (52)45 (56)48 (60)52 (64)55 (64)58 (64)61 (61)

64 (64)

N o r m a l T y p e s ( S p a c e S a v in g T y p e s )Outdoor unit multi connection

piping kit

–––––––

BHFP22P100

BHFP22P151

RXQ14P + RXQ18P x 2RXQ16P + RXQ18P x 2

RXQ18P x 3

625 to 1,625 (1,625)650 to 1,690 (1,690)675 to 1,755 (1,755)

RXQ50PRXQ52PRXQ54P

50 HP52 HP54 HP

Maximum number ofconnectable indoor units*

Total capacity index of connectable indoor units*HP Combination

RXQ8P x 2 200 to 520 (640)

Model name

RXQ16PH16 HP 26 (32)

H ig h - C O P T y p e s ( E n e r g y S a v in g T y p e s )Outdoor unit multi connection

piping kit

BHFP22P100RXQ8P + RXQ10P 225 to 585 (720)RXQ18PH18 HP 29 (36)

RXQ8P x 3 300 to 780 (780)RXQ24PH24 HP 39 (39)RXQ8P x 2 + RXQ10P 325 to 845 (845)RXQ26PH26 HP 42 (42)RXQ8P x 2 + RXQ12P 350 to 910 (910)RXQ28PH28 HP 45 (45)

RXQ8P + RXQ10P + RXQ12P 375 to 975 (975)RXQ30PH30 HP 48 (48)52 (52)55 (55)58 (58)

RXQ8P + RXQ12P x 2 400 to 1,040 (1,040)RXQ32PH32 HPRXQ10P + RXQ12P x 2 425 to 1,105 (1,105)RXQ34PH34 HP

BHFP22P151RXQ12P x 3 450 to 1,170 (1,170)RXQ36PH36 HP

RXQ12P x 2 + RXQ14P 475 to 1,235 (1,235)RXQ38PH38 HP 61 (61)RXQ12P x 2 + RXQ16P 500 to 1,300 (1,300)RXQ40PH40 HP

64 (64)RXQ12P x 2 + RXQ18P 525 to 1,365 (1,365)RXQ42PH42 HPRXQ12P + RXQ16P x 2 550 to 1,430 (1,430)RXQ44PH44 HP

RXQ12P + RXQ16P + RXQ18P 575 to 1,495 (1,495)RXQ46PH46 HPRXQ16P x 3 600 to 1,560 (1,560)RXQ48PH48 HP

RXQ16P x 2 + RXQ18P 625 to 1,625 (1,625)RXQ50PH50 HP

FXCQ20MVE FXCQ25MVE FXCQ32MVE FXCQ40MVE FXCQ50MVE FXCQ63MVE FXCQ80MVE FXCQ125MVE

2.37,800

2,000

2.99,900

2,500

3.712,600

3,200

4.716,000

4,000

5.819,800

5,000

7.324,900

6,300

9.331,700

8,000

14.52.2 2.8 3.6 4.5 5.6 7.1 9.0 14.0

49,500

12,500

C e ilin g M o u n t e d C a s s e t t e <D o u b le f lo w > T y p e

MODEL FXFQ25MVE

Cooling capacity

kW(*1)(*2)

2.99,900

2,500

FXFQ32MVE

3.712,600

3,200

FXFQ40MVE

4.716,000

4,000

FXFQ50MVE

5.819,800

5,000

FXFQ63MVE

7.324,900

6,300

FXFQ80MVE

9.32.8 3.6 4.5 5.6 7.1 9.0

31,700

8,000

FXFQ100MVE

11.639,600

10,000

FXFQ125MVE

14.511.2 14.0

49,500

12,500

Btu/h(*1)

kcal/h(*1)

1 phase, 220-240V/220V, 50/60HzPower supply

C e ilin g M o u n t e d C a s s e t t e <M u lt i- f lo w > T y p e

MODEL

Cooling capacity

kW(*1)(*2)

Btu/h(*1)

kcal/h(*1)

1 phase, 220-240V/220V, 50/60HzPower supply

Galvanised steel plate

7/5

247/17732/27

305X775X600

26.0

6.4

12.7

VP25 (External Dia, 32/Internal Dia, 25)

BYBC32G-W1

White (10Y9/0.5)

53X1,030X680

8.0

9/6.5

318/23034/28

305X775X600

26.0

6.4

12.7

53X1,030X680

8.0

9/6.5

318/23034/28

305X775X600

26.0

6.4

12.7

53X1,030X680

8.0

12/9

424/31834/29

305X990X600

31.0

6.4

12.7

BYBC50G-W1

53X1,245X680

8.5

12/9

424/31834/29

305X990X600

32.0

6.4

12.7

53X1,245X680

8.5

16.5/13

582/45937/32

305X1,175X600

35.0

9.5

15.9

BYBC63G-W1

53X1,430X680

9.5

26/21

918/74139/34

305X1,665X600

47.0

9.5

15.9

BYBC125G-W1

53X1,920X680

12.0

33/25

1,165/88344/38

34/29 36/30 36/30 37/32 37/32 39/34 41/36 46/40305X1,665X600

48.0

9.5

15.9

53X1,920X680

12.0

Casing

Air flow rate (Hi/Lo) m3/min

cfm

Dimensions (HXWXD) mm

Machine weight kg

Piping connections Liquid(Flare)mm

Gas(Flare)mm

Drain piping

Panel(Option) Model

Colour

mm

Sound level (Hi/Lo)

Dimensions(HXWXD)

weight kg

dB (A)

50 Hz/60 Hz 220V50 Hz 240V

Galvanised steel plate

246X840X840

24.0

6.4

12.7

VP25 (External Dia, 32/Internal Dia, 25)

BYCP125D-W1

White (10Y9/0.5)

45X950X950

5.5

45X950X950

5.5

45X950X950

5.5

45X950X950

5.5

45X950X950

5.5

45X950X950

5.5

45X950X950

5.5

45X950X950

5.5

246X840X840

24.0

6.4

12.7

15/1113/10 13/10

30/27 30/27

530/388

31/27

246X840X840

24.0

6.4

12.7

16/11

565/388459/353 459/353

32/27

246X840X840

24.0

6.4

12.7

18.5/14

653/494

33(34) /28

246X840X840

25.0

9.5

15.9

20/15

706/530

36/31

246X840X840

25.0

9.5

15.9

26/21

918/741

39/33

288X840X840

29.0

9.5

15.9

30/24

1,059/847

42(43) /36

288X840X840

29.0

9.5

15.9

Casing

Air flow rate (Hi/Lo) m3/min

cfm

Dimensions (HXWXD) mm

Machine weight kg

Piping connections Liquid(Flare)mm

Gas(Flare)mm

Drain piping

Panel(Option) Model

Colour

mmDimensions(HXWXD)

weight kg

dB(A)Sound level (Hi/Lo)

Note : Specifications are based on the following conditions;•Cooling : (*1) Indoor temp. of 27-°CDB, 19.5°CWB, and outdoor temp. of 35.0°CDB. (*2) Indoor temp. of 27°CDB, 19.0°CWB, and outdoor temp. of 35.0°CDB.•Equivalent piping length : 7.5m•Level difference : 0m•Capacity of indoor unit is only for reference. Actual capacity of indoor unit is based on the total capacity index. (See ENGINEERING DATA for details.)•Sound level : Anechoic chamber conversion value, measured at a point 1.5 m downward from the unit centre. During actual operation, these values are normally somewhat higher as a result of ambient conditions.

: The values of Hi mode Sound level represent those during cooling operation.Those during heating operation are shown in brackets for two models only.

Outdoor Unit Type Specifications

Note: •For multiple connection of 20 HP systems and above, the above Daikin optional kit (separately sold) is required.*Values inside brackets are based on connection of indoor units rated at maximum capacity, 200% from single outdoor units, 160% from double outdoor units, and 130% from triple outdoor units. Refer to page 9 for notes on connection capacity of indoor units.

Note: •For multiple connection of 16 HP systems and above, the above Daikin optional kit (separately sold) is required.*Values inside brackets are based on connection of indoor units rated at maximum capacity, 200% from single outdoor units, 160% from double outdoor units, and 130% from triple outdoor units. Refer to page 9 for notes on connection capacity of indoor units.

Page 21: C OOLING O - Premium Serve

4039

INDOOR UNITSINDOOR UNITS

C e ilin g M o u n t e d C a s s e t t e C o r n e r T y p e

S lim C e ilin g M o u n t e d D u c t T y p e ( 7 0 0 m m w id t h t y p e )

Cooling capacity

kW(*1)

7,800

2,000

9,900

2,500

12,600

3,200

(*2) 2.2

Btu/h(*1)

kcal/h(*1)

1 phase, 220-240 V/220 V, 50/60 HzPower supply

2.8 3.6

2.3 2.9 3.7

FXDQ20PVET FXDQ25PVET FXDQ32PVET

Galvanised steel plate

8.0/6.4

282/226

8.0/6.4

282/226

8.0/6.4

282/226

33/29 33/29 33/29

Air flow rate (Hi/Lo) m3/min

cfm

dB(A)

Casing

200X700X620

23.0

6.4

12.7

200X700X620

23.0

6.4

12.7

200X700X620

23.0

6.4

12.7

Dimensions(HXWXD)

Sound level (Hi/Lo)

PaExternal static pressure

mm

Machine weight kg

Piping connections Liquid(Flare)mm

Gas(Flare)mm

Drain piping VP20 (External Dia, 26/Internal Dia, 20)

30-10 1

32

Note : Specifications are based on the following conditions;•Cooling : (*1) Indoor temp. of 27-°CDB, 19.5°CWB, and outdoor temp. of 35.0°CDB. (*2) Indoor temp. of 27°CDB, 19.0°CWB, and outdoor temp. of 35.0°CDB.

1 : External static pressure is changeable to set by the remote controller. This pressure means "High static pressure - Standard". (Factory setting is 10 Pa.) 2 : The values of operation sound level represent those for rear-suction operation. Sound level values for bottom-suction operation can be obtained by adding 5 dB. 3 : Values are based on the following conditions: external static pressure of 10 Pa.•Equivalent piping length : 7.5m •Level difference : 0m•Capacity of indoor unit is only for reference. Actual capacity of indoor unit is based on the total capacity index. (See ENGINEERING DATA for details.)•Sound level (FXKQ-MA) Anechoic chamber conversion value, measured at a point 1 m in front of the unit and 1 m downward.

(FXDQ-P) Anechoic chamber conversion value, measured at a point 1.5 m downward from the unit centre. During actual operation, these values are normally somewhat higher as a result of ambient conditions.

MODEL without drain-up pump

FXDQ20PVE FXDQ25PVE FXDQ32PVEwith drain-up pump

FXKQ25MAVE

kW(*1) 2.9

9,9002,500

Btu/h(*1)kcal/h(*1)

FXKQ32MAVE

3.712,6003,200

FXKQ40MAVE

4.716,0004,000

FXKQ63MAVE

7.3(*2) 2.8 3.6 4.5 7.1

24,9006,300

1 phase, 220-240V/220V, 50/60HzPower supplyCooling capacity

MODEL

Galvanised steel plate11/9 11/9 13/10 18/15

388/318 388/318 459/353 635/530

215X1,110X71031.0 6.4

12.7VP25 (External Dia, 32/Internal Dia, 25)

BYK45FJW1White (10Y9/0.5)

70X1,240X8008.5

215X1,110X71031.0 6.4

12.7

70X1,240X8008.5

215X1,110X71031.0 6.4

12.7

70X1,240X8008.5

215X1,310X71034.0 9.5

15.9

BYK71FJW1

70X1,440X8009.5

Dimensions (HXWXD) mmMachine weight kgPiping connections Liquid(Flare)mm

Gas(Flare)mmDrain piping

Panel (Option) ModelColour

mmweight kg

Dimensions(HXWXD)

38/33 38/33 40/34 42/3740/35 40/35 42/36 44/39

CasingAir flow rate (Hi/Lo) m3/min

cfm50 Hz50 Hz

Sound level (Hi/Lo) dB (A)

50 Hz/60 Hz 220V50 Hz 240V

Cooling capacity

kW(*1)

7,800

2,000

9,900

2,500

12,600

3,200

16,000

4,000

19,800

5,000

24,900

6,300

(*2) 2.2

Btu/h(*1)

kcal/h(*1)

S lim C e ilin g M o u n t e d D u c t T y p e ( 9 0 0 / 1, 10 0 m m w id t h t y p e )

1 phase, 220-240 V/220 V, 50/60 HzPower supply

2.8 3.6 4.5 5.6 7.1

2.3 2.9 3.7 4.7 5.8 7.3

without drain-up pump

with drain-up pump

FXDQ20NVET FXDQ25NVET FXDQ32NVET FXDQ40NVET FXDQ50NVET FXDQ63NVETMODEL

FXDQ20NAVE FXDQ25NAVE FXDQ32NAVE FXDQ40NAVE FXDQ50NAVE FXDQ63NAVE

C e ilin g M o u n t e d B u ilt - in T y p e

Note : Specifications are based on the following conditions;•Cooling : (*1) Indoor temp. of 27-°CDB, 19.5°CWB, and outdoor temp. of 35.0°CDB. (*2) Indoor temp. of 27°CDB, 19.0°CWB, and outdoor temp. of 35.0°CDB.

1 : External static pressure is changeable to set by the remote controller. This pressure means "High static pressure - Standard". (Factory setting is 15Pa)2 : The values of operation sound level represent those for rear-suction operation. Sound level values for bottom-suction operation can be obtained by adding 5 dB.

3 : Values are based on the following conditions: external static pressure of 15 Pa. 4 : External static pressure is changeable to change over the connectors inside electrical box, this pressure means "High static pressure-Standard-Low static pressure". 5 : External static pressure is changeable to change over the connectors inside electrical box, this pressure means "High static pressure-Standard".•Equivalent piping length : 7.5m •Level difference : 0m•Capacity of indoor unit is only for reference. Actual capacity of indoor unit is based on the total capacity index. (See ENGINEERING DATA for details.)•Sound level (FXDQ-N(A)) Anechoic chamber conversion value, measured at a point 1.5 m downward from the unit centre.

(FXSQ-M) Anechoic chamber conversion value, measured at a point 1.5 m downward from the unit centre. During actual operation, these values are normally somewhat higher as a result of ambient conditions.

Galvanised steel plate

9.5/7.5

335/265

9.5/7.5

335/265

10.5/8.5

371/300

10.5/8.5

371/300

12.5/10.0

441/353

16.5/13.0

583/459

33/29 33/29 33/29 34/30 35/31 36/32

Air flow rate (Hi/Lo) m3/min

cfm

dB(A)

Casing

200X900X620

26.0

6.4

12.7

200X900X620

26.0

6.4

12.7

200X900X620

26.0

6.4

12.7

200X900X620

27.0

6.4

12.7

200X900X620

28.0

6.4

12.7

200X1,100X620

31.0

9.5

15.9

Dimensions(HXWXD)

PaExternal static pressure

mm

Machine weight kg

Piping connections Liquid(Flare)mm

Gas(Flare)mm

Drain piping VP20 (External Dia, 26/Internal Dia, 20)

44-15 1

Sound level (Hi/Lo) 32

FXSQ20MVE FXSQ25MVE FXSQ32MVE FXSQ40MVE FXSQ50MVE FXSQ63MVE FXSQ80MVE FXSQ100MVE FXSQ125MVE

Cooling capacity

(*1)7,8002,000

9,9002,500

12,6003,200

16,0004,000

19,8005,000

24,9006,300

31,7008,000

39,60010,000

(*2) 2.2

49,50012,500

Btu/h(*1)kcal/h(*1)

1 phase, 220-240V/220V, 50/60HzPower supply

2.8 3.6 4.5 5.6 7.1 9.0 11.2 14.02.3 2.9 3.7 4.7 5.8 7.3 9.3 11.6 14.5

kW

MODEL

Galvanised steel plate9/6.5 9/6.5 9.5/7 11.5/9 15/11 21/15.5 27/21.5 28/22 38/28

318/230 318/230 335/247 406/318 530/388 741/547 953/759 988/777 1,341/988

Casing

300X550X80030.0 6.4

12.7VP25 (External Dia, 32/Internal Dia, 25)

300X550X80030.0 6.4

12.7

38/32

300X550X80030.0 6.4

12.7

38/32

300X700X80030.0 6.4

12.7

300X700X80031.0 6.4

12.7

300X1,000X80041.0 9.5

15.9

43/37

300X1,400X80051.0 9.5

15.9

43/37

300X1,400X80051.0 9.5

15.9

46/41

300X1,400X80052.0 9.5

15.9

Dimensions(HXWXD) mm

External static pressure Pa

Machine weight kgPiping connections Liquid(Flare)mm

Gas(Flare)mm

White (10Y9/0.5)55X650X500

3.0

55X650X5003.0

55X650X5003.0

55X800X5003.5

55X800X5003.5

55X1,100X5004.5

55X1,500X5006.5

55X1,500X5006.5

55X1,500X5006.5

Panel(Option)Colour

mm

BYBS32DJW1 BYBS32DJW1 BYBS32DJW1 BYBS45DJW1 BYBS45DJW1 BYBS71DJW1 BYBS125DJW1 BYBS125DJW1 BYBS125DJW1

41/36 42/3537/32 37/3240/34 40/34 45/39 45/39 48/4343/38 44/3739/34 39/34

Sound level (Hi/Lo)

Model

Dimensions(HXWXD)

Drain piping

weight kg

Air flow rate (Hi/Lo)

220V240V

50 Hz

88-39-20 88-39-20 64-39-15 88-49-20 88-59-29 88-49-20 113-82 107-75 78-394 4 4 4 4 4 5 55

m3/mincfm

50 Hz50 Hz50 Hz

dB (A)

Specifications

Page 22: C OOLING O - Premium Serve

4241

INDOOR UNITSINDOOR UNITS

MODEL FXHQ32MAVE

Cooling capacity

kW(*1) 3.7

12,600

3,200

FXHQ63MAVE

7.324,900

6,300

FXHQ100MAVE

11.6(*2) 3.6 7.1 11.2

39,600

10,000

Btu/h(*1)

kcal/h(*1)

C e ilin g S u s p e n d e d T y p e

1 phase, 220-240 V/220 V, 50/60 HzPower supply

MODEL FXMQ40MAVE FXMQ50MAVE FXMQ63MAVE FXMQ80MAVE FXMQ100MAVE FXMQ125MAVE FXMQ200MAVE FXMQ250MAVE

Cooling capacity

kW(*1) 4.7

16,000

4,000

5.8

19,800

5,000

7.3

24,900

6,300

9.3

31,700

8,000

11.6

39,600

10,000

14.5

49,500

12,500

23.0

78,500

19,800

28.8(*2) 4.5 5.6 7.1 9.0 11.2 14.0 22.4 28.0

98,300

24,800

Btu/h(*1)

kcal/h(*1)

C e ilin g M o u n t e d D u c t T y p e

1 phase, 220-240 V/220V, 50/60 HzPower supply

White (10Y9/0.5)

cfm

12/10 17.5/14 25/19.5

Dimensions(HXWXD) mm

Machine weight kg

Piping connections Liquid(Flare)mmGas(Flare)mm

Drain piping

36/31 39/34 45/37

195X960X680

24.0

6.4 12.7

VP20 (External Dia, 26/Internal Dia, 20)

195X1,160X680

28.0

9.5 15.9

195X1,400X680

33.0

9.5 15.9

Casing

m3/minAir flow rate (Hi/Lo)

424/353 883/688618/494

dB(A)Sound level (Hi/Lo)

Note : Specifications are based on the following conditions;•Cooling : (*1) Indoor temp. of 27-°CDB, 19.5°CWB, and outdoor temp. of 35.0°CDB.

(*2) Indoor temp. of 27°CDB, 19.0°CWB, and outdoor temp. of 35.0°CDB. 1 : External static pressure is changeable to change over the connectors inside electrical box, this pressure means "High static pressure-Standard".•Equivalent piping length : 7.5m•Level difference : 0m•Capacity of indoor unit is only for reference. Actual capacity of indoor unit is based on the total capacity index. (See ENGINEERING DATA for details.)•Sound level : (FXMQ-MA) Anechoic chamber conversion value, measured at a point 1.5 m downward from the unit centre.

(FXHQ-M) Anechoic chamber conversion value, measured at a point 1 m in front of the unit and 1 m downward.During actual operation, these values are normally somewhat higher as a result of ambient conditions.

Galvanised steel plate

14/11.5

494/406

39/35

390X720X690

44.0

6.4

12.7

VP25 (External Dia, 32/Internal Dia, 25)

14/11.5

494/406

39/35

390X720X690

44.0

6.4

12.7

14/11.5

494/406

39/35

390X720X690

44.0

9.5

15.9

19.5/16

688/565

42/38

390X720X690

45.0

9.5

15.9

29/23

1,024/812

43/39

390X1,110X690

63.0

9.5

15.9

36/29

1,271/1,024

45/42

390X1,110X690

65.0

9.5

15.9

58/50

2,047/1,765

48/45

470X1,380X1,100

137.0

9.5

19.1(Brazing)

PS1B

72/62

2,542/2,189

48/4541/37 41/37 41/37 44/40 45/41 47/44 49/46 49/46

470X1,380X1,100

137.0

9.5

22.2(Brazing)

m3/min

cfm

Dimensions (HXWXD) mm

Machine weight kg

Piping connections Liquid(Flare)mm

Gas(Flare)mm

Drain piping

Casing

Air flow rate (Hi/Lo)

Sound level (Hi/Lo)

1

Pa (50Hz) 157-118 157-118 157-118 157-108 157-98 191-152 221-132 270-147 External static pressure 1 1 1 1 1 1 1 1

dB (A)

50 Hz/60 Hz 220V

50 Hz 240V

F lo o r S t a n d in g T y p e / C o n c e a le d F lo o r S t a n d in g T y p e

MODELFXLQ20MAVE

Cooling capacity

2.3

7,800

2,000

Btu/h(*1)

kcal/h(*1)

Power supply

2.2

FXLQ25MAVE

2.9

9,900

2,500

2.8

FXLQ32MAVE

3.7

12,600

3,200

3.6

FXLQ40MAVE

4.7

16,000

4,000

4.5

FXLQ50MAVE

5.8

19,800

5,000

5.6

FXLQ63MAVE

FXNQ20MAVE FXNQ25MAVE FXNQ32MAVE FXNQ40MAVE FXNQ50MAVE FXNQ63MAVE

7.3

24,900

6,300

7.1kW

(*1)

(*2)

FXLQ

FXNQ

1 phase, 220-240 V/220 V, 50/60 Hz

W a ll M o u n t e d T y p e

MODEL FXAQ25MAVE

Cooling capacity

2.9

Btu/h(*1)

kcal/h(*1)

1 phase, 220-240 V/220 V, 50/60 HzPower supply

FXAQ40MAVE

4.7

9,900 16,000

2,500 4,000

FXAQ32MAVE

3.7

12,600

3,200

2.8

FXAQ20MAVE

2.3

7,800

2,000

2.2 4.53.6kW

(*1)

(*2)

FXAQ63MAVE

7.3

24,900

6,3005,000

FXAQ50MAVE

5.8

19,800

7.15.6

White (3.0Y8.5/0.5)

36/29

290X795X230

11.0

Casing

37/29

290X795X230

11.0

39/34

290X1,050X230

14.0

282/177 318/194 424/318

Dimensions (HXWXD) mm

Machine weight kg

Piping connections Liquid(Flare)mm

Gas(Flare)mm

Drain piping

m3/minAir flow rate (Hi/Lo)

cfm

8/5 9/5.5

35/29

290X795X230

11.0

265/159

7.5/4.5 12/9

VP13 (External Dia, 18/Internal Dia, 13)

6.4 6.4 6.4 6.4

12.7 12.7 12.7 12.7

42/36

290X1,050X230

14.0

15/12 19/14

530/424

46/39

290X1,050X230

14.0

671/494

6.4 9.5

12.7 15.9

dB(A)Sound level (Hi/Lo)

Note : Specifications are based on the following conditions ;•Cooling : (*1) Indoor temp. of 27-°CDB, 19.5°CWB, and outdoor temp. of 35.0°CDB.

(*2) Indoor temp. of 27°CDB, 19.0°CWB, and outdoor temp. of 35.0°CDB.•Equivalent piping length : 7.5m•Level difference : 0m•Capacity of indoor unit is only for reference. Actual capacity of indoor unit is based on the total capacity index. (See ENGINEERING DATA for details.)•Sound level : (FXAQ-MA) Anechoic chamber conversion value, measured at a point 1 m in front of the unit and 1 m downward. (FXLQ-MA,FXNQ-MA) Anechoic chamber conversion value, measured at a point 1.5 m in front of the unit at a height of 1.5m. During actual operation, these values are normally somewhat higher as a result of ambient conditions.

FXLQ:Ivory white (5Y7.5/1) / FXNQ:Galvanised steel plateCasing

Air flow rate (Hi/Lo) m3/min

cfm

7/6

247/212

600X1,000X222

25.0

6.4

12.7

21O.D.

Dimensions (HXWXD)

Machine weight

Piping connections Liquid(Flare)mm

Gas(Flare)mm

Drain piping

7/6

247/212

600X1,000X222

25.0

6.4

12.7

282/212 388/300 494/388 565/424

8/6

600X1,140X222

30.0

6.4

12.7

11/8.5

600X1,140X222

30.0

6.4

12.7

14/11

600X1,420X222

36.0

6.4

12.7

16/12

600X1,420X222

610X930X220 610X930X220 610X1,070X220 610X1,070X220 610X1,350X220 610X1,350X220

36.0

19.0 19.0 23.0 23.0 27.0 27.0

9.5

15.9

mmFXLQ

FXNQ

kgFXLQ

FXNQ

35/32 35/32 35/32 38/33 39/34 40/35

37/34 37/34 37/34 40/35 41/36 42/37Sound level (Hi/Lo) dB

(A)50 Hz/60 Hz 220V

50 Hz 240V

Specifications

Page 23: C OOLING O - Premium Serve

4443

OUTDOOR UNITSINDOOR UNITS

C e ilin g s u s p e n d e d c a s s e t t e t y p e

kW (*1)(*2)

Kcal/h(*1)Power supply

8.3

7,1001 phase, 220-240 V, 50 Hz

Btu/h(*1) 28,30011.6

10,00039,600

14.58.0 11.2 14.0

12,50049,500Cooling capacity

ModelIndoor unit

Connection unit BEVQ71MAVEFXUQ71MAV1

BEVQ100MAVEFXUQ100MAV1

BEVQ125MAVEFXUQ125MAV1

Indoorunit m3/minAir flow rate (H/L)

Sound level (230 V)

Casing

dBAmmDimensions (HXWXD)kgMachine weight

40/35

Piping connectionsLiquidGas

Drain piping VP 20 (External Dia. 26/Internal Dia. 20)

25

White(10Y9/0.5)19/14

671/494cfm

165X895X895

9.5 (Flare)15.9 (Flare)

43/38

31

29/211,024/741

230X895X89544/39

31

32/231,130/812

230X895X895

mm

Note : Specifications are based on the following conditions ;•Cooling : (*1) Indoor temp. of 27-°CDB, 19.5°CWB, and outdoor temp. of 35.0°CDB.

(*2) Indoor temp. of 27°CDB, 19.0°CWB, and outdoor temp. of 35.0°CDB.•Equivalent piping length : 7.5m•Level difference : 0m•Capacity of indoor unit is only for reference. Actual capacity of indoor unit is based on the total capacity index. (See ENGINEERING DATA for details.)•Sound level : (FXUQ-MA) Anechoic chamber conversion value, measured at a point 1.5 m below the unit centre. During actual operation, these values are normally somewhat higher as a result of ambient conditions.

Connection unit series indoor units* A type of BEV unit is necessary for each Connection unit series indoor unit. Refer to the Engineering Data for details.* If indoor units from the Connection unit series are connected within a single refrigerant system to indoor units from any other series,

cooling/heating switchover will not be possible using the remote controller of the Connection unit series indoor units. However, if the remote controller of an indoor unit from the other series is set as a master remote controller, cooling/heating switchover will be possible.

* If all indoor units are from the Connection unit series, an outdoor unit Cool/Heat selector will be needed to enable cooling/heating switchover. * Group control between Connection Unit series equipment within one system is possible. However, group control with the other VRV indoor

units is not possible.

N o r m a l T y p e s ( S p a c e S a v in g T y p e s )

Cooling capacityBtu/h(*1)

(*1)kW(*2)

Power supply

14.148,10012,100

22.576,80019,400

28.296,20024,300

14.0 22.4 28.033.7

115,00029,000

33.540.2

137,00034,600

40.0

3 phase, 380–415 V, 50 Hz, 4 wires system

45.3155,00039,000

45.0

RXQ5PY1 RXQ8PY1 RXQ10PY1 RXQ12PY1 RXQ14PY1 RXQ16PY1 RXQ18PY1

49.3168,00042,400

49.0

MODEL

kcal/h(*1)

90.5

MODELConstituent Units RXQ8PY1

RXQ12PY1RXQ10PY1RXQ12PY1

RXQ8PY1RXQ16PY1

RXQ8PY1RXQ18PY1

RXQ10PY1RXQ18PY1

RXQ12PY1RXQ18PY1

RXQ20PY1 RXQ22PY1 RXQ24PY1 RXQ26PY1 RXQ28PY1 RXQ30PY1 RXQ32PY1RXQ16PY1RXQ16PY1

90.0

Power supply 3 phase, 380–415 V, 50 Hz, 4 wires systemCooling capacity

Btu/h(*1)(*1)kW(*2)

kcal/h(*1) 77,800

56.2 61.9 67.8 71.8 77.5 83.055.9 61.5 67.4 71.4 77.0 82.5

48,300 53,200211,000

58,300231,000

61,700250,000

66,700264,000

71,400283,000

Refrigerant oil

Refrigerant

Motor output kW

Refrigerant charge kg

Refrigerant oil charge

Machine weight kgdB(A)

Dimensions(HXWXD) mmm3/min

Capacity control

Compressor

Sound level (*3)

%

Air flow rate

Casing colour

R410A

2.8X1 3.8X1 (1.2+4.5)X1

6.2 7.7 8.4

160 205 24954 57 58

1,680X635X765 1,680X930X76595 180 185

28560

233

28-100 20-100 14-100

9.5 (Brazing) 15.9 (Brazing)

9.5 (Brazing) 19.1 (Brazing)

9.5 (Brazing) 22.2 (Brazing)

Hermetically sealed scroll type(0.3+4.5+4.5)X1

32960

233

14-100 10-100

10.0

12.7 (Brazing) 28.6 (Brazing)

12.3

12.7 (Brazing) 28.6 (Brazing)

Ivory white (5Y7.5/1)

(2.5+4.5)X1

1,680X1,240X76532960

233

10-100

12.5

12.7 (Brazing) 28.6 (Brazing)

(1.4+4.5+4.5)X1

34163

239

9-100

12.7

15.9 (Brazing) 28.6 (Brazing)

(3.0+4.5+4.5)X1

Piping connections Liquid pipe mmGas pipe mm

Refer to the nameplate of the compressor

19.1 (Brazing) 34.9 (Brazing)

63329+329

(1,680X930X765)+(1,680X1,240X765)

5-100

R410ARefrigerant

Motor output kW ((1.4+4.5+4.5)X1)+((1.4+4.5+4.5)X1)

Refrigerant charge kg

Refrigerant oil charge

Machine weight kgdB(A)

Dimensions(HXWXD) mmm3/min

Capacity control

Compressor

Sound level (*3)

%

Air flow rate

Casing colour

Piping connections Liquid pipe mmGas pipe mm

Hermetically sealed scroll typeIvory white (5Y7.5/1)

233+233

12.5+12.5

15.9 (Brazing) 28.6 (Brazing)

62205+285

15.9 (Brazing) 28.6 (Brazing)

62249+285

15.9 (Brazing) 34.9 (Brazing)

62205+329

19.1 (Brazing) 34.9 (Brazing)

64205+341

19.1 (Brazing) 34.9 (Brazing)

64249+341

19.1 (Brazing) 34.9 (Brazing)

65285+341

(1,680X1,240X765)+(1,680X1,240X765)

8 7 6 6 5 5

(3.8X1)+((2.5+4.5)X1)

((1.2+4.5)X1)+((2.5+4.5)X1)

(3.8X1)+((1.4+4.5+4.5)X1)

(3.8X1)+((3.0+4.5+4.5)X1)

((1.2+4.5)X1)+((3.0+4.5+4.5)X1)

((2.5+4.5)X1)+((3.0+4.5+4.5)X1)

180+233 185+233 180+233 180+239 185+239 233+239

7.7+10.0 8.4+10.0 7.7+12.5 7.7+12.7 8.4+12.7 10.0+12.7

•Sound level : (*3) Anechoic chamber conversion value, measured at a point 1 m in front of the unit at a height of 1.5 m.

During actual operation, these values are normally somewhat higher as a result of ambient conditions.

Use C1220T-1/2H for over 19.12. Total refrigerant volume should be 100 kg or less.

Refrigerant oilRefer to the nameplate of the compressor

Note : 1. Specifications are based on the following conditions;•Cooling : (*1) Indoor temp. of 27-°CDB, 19.5°CWB, and outdoor temp. of 35.0°CDB. (*2) Indoor temp. of 27°CDB, 19.0°CWB, and outdoor temp. of 35.0°CDB.•(*1)(*2) Equivalent piping length : 7.5m, level difference 0m.

Specifications

Page 24: C OOLING O - Premium Serve

4645

OUTDOOR UNITSOUTDOOR UNITS

N o r m a l T y p e s ( S p a c e S a v in g T y p e s ) H ig h - C O P T y p e s ( E n e r g y S a v in g T y p e s )

Power supply 3 phase, 380–415 V, 50 Hz, 4 wires systemCooling capacity

Btu/h(*1)(*1)kW(*2)

kcal/h(*1) 81,400323,000

85,100338,000

91,200362,000

97,200386,000

101,000399,000

104,000413,000

94.6 99.0 106 113 117 12194.0 98.0 105 112 116 120

MODEL MODEL

MODEL

Constituent Units RXQ16PY1RXQ18PY1

RXQ18PY1RXQ18PY1

RXQ8PY1RXQ12PY1RXQ18PY1

RXQ8PY1RXQ16PY1RXQ16PY1

RXQ34PY1 RXQ36PY1 RXQ38PY1 RXQ40PY1 RXQ42PY1 RXQ44PY1RXQ8PY1RXQ16PY1RXQ18PY1

RXQ8PY1RXQ18PY1RXQ18PY1

Power supply 3 phase, 380–415 V, 50 Hz, 4 wires systemCooling capacity

Btu/h(*1)(*1)kW(*2)

kcal/h(*1) 109,000433,000

114,000454,000

120,000474,000

124,000491,000

127,000505,000

127 133 139 144 148126 132 138 143 147

Constituent UnitsRXQ10PY1RXQ18PY1RXQ18PY1

RXQ12PY1RXQ18PY1RXQ18PY1

RXQ14PY1RXQ18PY1RXQ18PY1

RXQ16PY1RXQ18PY1RXQ18PY1

RXQ46PY1 RXQ48PY1 RXQ50PY1 RXQ52PY1 RXQ54PY1RXQ18PY1RXQ18PY1RXQ18PY1

Refrigerant oilRefer to the nameplate of the compressor

19.1 (Brazing) 34.9 (Brazing)

65

19.1 (Brazing) 41.3 (Brazing)

66

19.1 (Brazing) 41.3 (Brazing)

65

19.1 (Brazing) 41.3 (Brazing)

64

19.1 (Brazing) 41.3 (Brazing)

65

19.1 (Brazing) 41.3 (Brazing)

67R410ARefrigerant

Motor output kW ((1.4+4.5+4.5)X1)+((3.0+4.5+4.5)X1)

((3.0+4.5+4.5)X1)+((3.0+4.5+4.5)X1)

(3.8X1)+((2.5+4.5)X1)+((3.0+4.5+4.5)X1)

(3.8X1)+((1.4+4.5+4.5)X1)+((1.4+4.5+4.5)X1)

(3.8X1)+((1.4+4.5+4.5)X1)+((3.0+4.5+4.5)X1)

(3.8X1)+((3.0+4.5+4.5)X1)+((3.0+4.5+4.5)X1)

Refrigerant charge kg

Refrigerant oil charge

Machine weight kgdB(A)

m3/min

Capacity control

Compressor

Sound level (*3)

%

Air flow rate

Casing colour

Piping connections Liquid pipe mmGas pipe mm

Hermetically sealed scroll type

233+239 239+239 180+233+239 180+233+233 180+233+239 180+239+239

12.5+12.7 12.7+12.7 7.7+10.0+12.7 7.7+12.5+12.5 7.7+12.5+12.7 7.7+12.7+12.7

329+341 341+341 205+285+341 205+329+329 205+329+341 205+341+341

(1,680X1,240X765)+(1,680X1,240X765) (1,680X930X765)+(1,680X1,240X765)+(1,680X1,240X765)Dimensions(HXWXD) mm

Ivory white (5Y7.5/1)5-100 4-100 4-100 4-100 4-100 4-100

•Sound level : (*3) Anechoic chamber conversion value, measured at a point 1 m in front of the unit at a height of 1.5 m.

During actual operation, these values are normally somewhat higher as a result of ambient conditions.

Use C1220T-1/2H for over 19.12. Total refrigerant volume should be 100 kg or less.

Refrigerant oilRefer to the nameplate of the compressor

19.1 (Brazing) 41.3 (Brazing)

67

19.1 (Brazing) 41.3 (Brazing)

67

19.1 (Brazing) 41.3 (Brazing)

67

19.1 (Brazing) 41.3 (Brazing)

67

19.1 (Brazing) 41.3 (Brazing)

68R410ARefrigerant

Motor output kW ((1.2+4.5)X1)+((3.0+4.5+4.5)X1)+((3.0+4.5+4.5)X1)

(1,680X930X765)+(1,680X1,240X

765)+(1,680X1,240X765)

((2.5+4.5)X1)+((3.0+4.5+4.5)X1)+((3.0+4.5+4.5)X1)

((0.3+4.5+4.5)X1)+((3.0+4.5+4.5)X1)+((3.0+4.5+4.5)X1)

((1.4+4.5+4.5)X1)+((3.0+4.5+4.5)X1)+((3.0+4.5+4.5)X1)

((3.0+4.5+4.5)X1)+((3.0+4.5+4.5)X1)+((3.0+4.5+4.5)X1)

Refrigerant charge kg

Refrigerant oil charge

Machine weight kgdB(A)

m3/min

Capacity control

Compressor

Sound level (*3)

%

Air flow rate

Casing colour

Piping connections Liquid pipe mmGas pipe mm

Hermetically sealed scroll type

185+239+239 233+239+239 233+239+239 233+239+239 239+239+239

8.4+12.7+12.7 10.0+12.7+12.7 12.3+12.7+12.7 12.5+12.7+12.7 12.7+12.7+12.7

249+341+341 285+341+341 329+341+341 329+341+341 341+341+341

(1,680X1,240X765)+(1,680X1,240X765)+(1,680X1,240X765)Dimensions(HXWXD) mm

Ivory white (5Y7.5/1)3-100 3-100 3-100 3-100 3-100

Note : 1. Specifications are based on the following conditions;•Cooling : (*1) Indoor temp. of 27-°CDB, 19.5°CWB, and outdoor temp. of 35.0°CDB. (*2) Indoor temp. of 27°CDB, 19.0°CWB, and outdoor temp. of 35.0°CDB.•(*1)(*2) Equivalent piping length : 7.5 m, level difference 0 m.

89.9

Constituent Units RXQ8PY1RXQ8PY1

RXQ8PY1RXQ10PY1

RXQ8PY1RXQ8PY1RXQ8PY1

RXQ8PY1RXQ8PY1RXQ10PY1

RXQ8PY1RXQ8PY1RXQ12PY1

RXQ8PY1RXQ10PY1RXQ12PY1

RXQ16PHY1 RXQ18PHY1 RXQ24PHY1 RXQ26PHY1 RXQ28PHY1 RXQ30PHY1 RXQ32PHY1RXQ8PY1RXQ12PY1RXQ12PY1

89.4

Power supply 3 phase, 380–415 V, 50 Hz, 4 wires systemCooling capacity

Btu/h(*1)(*1)kW(*2)

kcal/h(*1) 77,300

45.1 50.7 67.6 73.2 78.8 84.444.8 50.4 67.2 72.8 78.3 83.9

38,800 43,600173,000

58,100231,000

63,000250,000

67,800269,000

72,600288,000

19.1 (Brazing) 34.9 (Brazing)

64205+285+285

(1,680X930X765)+(1,680X930X765)

5-100

R410ARefrigerant

Motor output kW (3.8X1)+((2.5+4.5)X1)+((2.5+4.5)X1)

Refrigerant charge kg

Refrigerant oil charge

Machine weight kgdB(A)

Dimensions(HXWXD)mm

m3/min

Capacity control

Compressor

Sound level (*3)

%

Air flow rate

Casing colour

Piping connections Liquid pipe mmGas pipe mm

Hermetically sealed scroll typeIvory white (5Y7.5/1)

180+233+233

7.7+10.0+10.0

12.7 (Brazing) 28.6 (Brazing)

60205+205

15.9 (Brazing) 28.6 (Brazing)

61205+249

(1,680X930X765)+(1,680X930X765)+(1,680X930X765)

15.9 (Brazing) 34.9 (Brazing)

62205+205+205

19.1 (Brazing) 34.9 (Brazing)

62205+205+249

19.1 (Brazing) 34.9 (Brazing)

63205+205+285

19.1 (Brazing) 34.9 (Brazing)

63205+249+285

(1,680X930X765)+(1,680X930X765)+(1,680X1,240X765)

(1,680X930X765)+(1,680X1,240X765)+(1,680X1,240X765)

1 8 7 6 6 5

(3.8X1)+(3.8X1) (3.8X1)+((1.2+4.5)X1) (3.8X1)+(3.8X1)+(3.8X1)

(3.8X1)+(3.8X1)+((1.2+4.5)X1)

(3.8X1)+(3.8X1)+((2.5+4.5)X1)

(3.8X1)+((1.2+4.5)X1)+((2.5+4.5)X1)

180+180 180+185 180+180+180 180+180+185 180+180+233 180+185+233

7.7+7.7 7.7+8.4 7.7+7.7+7.7 7.7+7.7+8.4 7.7+7.7+10.0 7.7+8.4+10.0Refrigerant oil

Refer to the nameplate of the compressor

Specifications

MODEL

Power supply 3 phase, 380–415 V, 50 Hz, 4 wires systemCooling capacity

Btu/h(*1)(*1)kW(*2)

kcal/h(*1) 82,200326,000

87,700348,000

92,900368,000

97,200386,000

101,000399,000

108,000427,000

95.6 102 108 113 117 12595.0 101 107 112 116 124

Constituent UnitsRXQ10PY1RXQ12PY1RXQ12PY1

RXQ12PY1RXQ12PY1RXQ12PY1

RXQ12PY1RXQ12PY1RXQ14PY1

RXQ12PY1RXQ12PY1RXQ16PY1

RXQ34PHY1 RXQ36PHY1 RXQ38PHY1 RXQ40PHY1 RXQ42PHY1 RXQ44PHY1RXQ12PY1RXQ12PY1RXQ18PY1

RXQ12PY1RXQ16PY1RXQ16PY1

Refrigerant oilRefer to the nameplate of the compressor

19.1 (Brazing) 34.9 (Brazing)

64

19.1 (Brazing) 41.3 (Brazing)

65

19.1 (Brazing) 41.3 (Brazing)

65

19.1 (Brazing) 41.3 (Brazing)

65

19.1 (Brazing) 41.3 (Brazing)

66

19.1 (Brazing) 41.3 (Brazing)

65R410ARefrigerant

Motor output kW ((1.2+4.5)X1)+((2.5+4.5)X1)+((2.5+4.5)X1)

((2.5+4.5)X1)+((2.5+4.5)X1)+((2.5+4.5)X1)

((2.5+4.5)X1)+((2.5+4.5)X1)+((0.3+4.5+4.5)X1)

((2.5+4.5)X1)+((2.5+4.5)X1)+((1.4+4.5+4.5)X1)

((2.5+4.5)X1)+((2.5+4.5)X1)+((3.0+4.5+4.5)X1)

((2.5+4.5)X1)+((1.4+4.5+4.5)X1)+((1.4+4.5+4.5)X1)

Refrigerant charge kg

Refrigerant oil charge

Machine weight kgdB(A)

m3/min

Capacity control

Compressor

Sound level (*3)

%

Air flow rate

Casing colour

Piping connections Liquid pipe mmGas pipe mm

Hermetically sealed scroll type

185+233+233 233+233+233 233+233+233 233+233+233 233+233+239 233+233+233

8.4+10.0+10.0 10.0+10.0+10.0 10.0+10.0+12.3 10.0+10.0+12.5 10.0+10.0+12.7 10.0+12.5+12.5

249+285+285 285+285+285 285+285+329 285+285+329 285+285+341 285+329+329

(1,680X930X765)+(1,680X1,240X765)+(1,680X1,240X765)

(1,680X1,240X765)+(1,680X1,240X765)+(1,680X1,240X765)Dimensions(HXWXD)

mm

Ivory white (5Y7.5/1)5-100 5-100 4-100 4-100 4-100 4-100

•Sound level : (*3) Anechoic chamber conversion value, measured at a point 1 m in front of the unit at a height of 1.5 m.

During actual operation, these values are normally somewhat higher as a result of ambient conditions.

Use C1220T-1/2H for over 19.12. Total refrigerant volume should be 100 kg or less.

Note : 1. Specifications are based on the following conditions;•Cooling : (*1) Indoor temp. of 27-°CDB, 19.5°CWB, and outdoor temp. of 35.0°CDB. (*2) Indoor temp. of 27°CDB, 19.0°CWB, and outdoor temp. of 35.0°CDB.•(*1)(*2) Equivalent piping length : 7.5 m, level difference 0 m.

Page 25: C OOLING O - Premium Serve

4847

INDOOR UNITSOUTDOOR UNITS

H ig h - C O P T y p e s ( E n e r g y S a v in g T y p e s ) C e ilin g m o u n t e d c a s s e t t e t y p e ( D o u b le f lo w t y p e )

FXFQ25M FXFQ32M FXFQ40M FXFQ50M FXFQ63M FXFQ80M FXFQ100M FXFQ125M1

4

BYCP125D-W1

KAFP556D80 KAFP556D160KAFP557D80 KAFP557D160KAFP552H80 KAFP552H160KAFP553H80 KAFP553H160

KDT-55D160

KDP55D160

Filter related

5 Fresh air intake kit

Decoration Panel2 KDBH55D160WSealing member of air discharge outlet3 KDBP55H160WAPanel spacer

High efficiency filter unit 65%High efficiency filter unit 90%Replacement high efficiency filter 65%Replacement high efficiency filter 90%Filter chamberLong life replacement filter Non-woven type

Chamber type Without T shape and fanWith T shape without fan

KDDFP55D160

Ultra long-life filterReplacement ultra long-life filter

Direct installation type

KAFJ551C160KAFP55D160KAFJ55K160HKDDP55D160

KDDP55D160KKDDJ55X160

No.

C e ilin g m o u n t e d s u p e r c a s s e t t e t y p e ( M u lt i f lo w t y p e )Type

Item

6 KDP55D80Branch duct chamber7 KKSJ55K160Chamber connection kit8 KDT-55D80Insulation kit for high humidity

No.

1

2

Decoration PanelHigh efficiency filter 65% 1 High efficiency filter 90% 1

Long life replacement filter

Filter related bottom suction

FXCQ20MFXCQ25MFXCQ32M

FXCQ40M FXCQ50M FXCQ63M FXCQ80M FXCQ125M

KAFJ532G36 KAFJ532G56 KAFJ532G160KAFJ532G80KAFJ533G36 KAFJ533G56 KAFJ533G160KAFJ533G80KDDFJ53G36Filter chamber KDDFJ53G56 KDDFJ53G160KDDFJ53G80KAFJ531G36 KAFJ531G56 KAFJ531G160KAFJ531G80

TypeItem

BYBC32G-W1 BYBC50G-W1 BYBC125G-W1BYBC63G-W1

Note: 1 Filter chamber is required if installing high efficiency filter.

C e ilin g m o u n t e d c a s s e t t e c o r n e r t y p eNo. Type

Item FXKQ25MA,FXKQ32MA,FXKQ40MA FXKQ63MA

1

2

BYK45FJW1 BYK71FJW1KPBJ52F56W KPBJ52F80WKAFJ521F56 KAFJ521F80

K-HV7AW K-HV9AWKDBJ52F56W KDBJ52F80WKFDJ52FA56 KFDJ52FA80

Panel related

Air inlet and air discharge outlet related

Decoration PanelPanel SpacerLong life replacement filterAir discharge grilleAir discharge blind panelFlexible duct (with shutter)

Note: 1 For without drain-up pump type only.

Note: 1 For without drain-up pump type only.

No. FXDQ20N, FXDQ25N, FXDQ32N, FXDQ40N, FXDQ50N FXDQ63N

1 KDT25N50 KDT25N63Insulation kit for high humidity

S lim c e ilin g m o u n t e d d u c t t y p e ( 9 0 0 / 1, 10 0 m m w id t h t y p e 1)Type

Item

No. FXDQ20P,FXDQ25P,FXDQ32P

1 KDT25N32Insulation kit for high humidity

S lim c e ilin g m o u n t e d d u c t t y p e ( 7 0 0 m m w id t h t y p e 1)Type

Item

Power supply 3 phase, 380–415 V, 50 Hz, 4 wires systemCooling capacity

Btu/h(*1)(*1)kW(*2)

kcal/h(*1) 111,000440,000

117,000464,000

120,000478,000

129 136 140128 135 139

MODELConstituent Units

RXQ12PY1RXQ16PY1RXQ18PY1

RXQ16PY1RXQ16PY1RXQ16PY1

RXQ46PHY1 RXQ48PHY1 RXQ50PHY1RXQ16PY1RXQ16PY1RXQ18PY1

Specifications Option List

Refrigerant oilRefer to the nameplate of compressor

19.1 (Brazing) 41.3 (Brazing)

66

19.1 (Brazing) 41.3 (Brazing)

65

19.1 (Brazing) 41.3 (Brazing)

66R410ARefrigerant

Motor output kW ((2.5+4.5)X1)+((1.4+4.5+4.5)X1)+((3.0+4.5+4.5)X1)

((1.4+4.5+4.5)X1)+((1.4+4.5+4.5)X1)+((1.4+4.5+4.5)X1)

((1.4+4.5+4.5)X1)+((1.4+4.5+4.5)X1)+((3.0+4.5+4.5)X1)

Refrigerant charge kg

Refrigerant oil charge

Machine weight kgdB(A)

m3/min

Capacity control

Compressor

Sound level (*3)

%

Air flow rate

Casing colour

Piping connections Liquid pipe mmGas pipe mm

Hermetically sealed scroll type

233+233+239 233+233+233 233+233+239

10.0+12.5+12.7 12.5+12.5+12.5 12.5+12.5+12.7

285+329+341 329+329+329 329+329+341

(1,680X1,240X765)+(1,680X1,240X765)+(1,680X1,240X765)

Dimensions(HXWXD) mm

Ivory white (5Y7.5/1)3-100 3-100 3-100

•Sound level : (*3) Anechoic chamber conversion value, measured at a point 1 m in front of the unit at a height of 1.5 m.

During actual operation, these values are normally somewhat higher as a result of ambient conditions.

Use C1220T-1/2H for over 19.12. Total refrigerant volume should be 100 kg or less.

Note : 1. Specifications are based on the following conditions;•Cooling : (*1) Indoor temp. of 27-°CDB, 19.5°CWB, and outdoor temp. of 35.0°CDB. (*2) Indoor temp. of 27°CDB, 19.0°CWB, and outdoor temp. of 35.0°CDB.•(*1)(*2) Equivalent piping length : 7.5 m, level difference 0 m.

Page 26: C OOLING O - Premium Serve

5049

OUTDOOR UNITS

CONTROL SYSTEM

INDOOR UNITS

No.

C e ilin g m o u n t e d d u c t t y p eFXMQ40MA FXMQ50MA FXMQ63MA FXMQ80MA FXMQ100MA FXMQ125MA FXMQ200MA FXMQ250MA

1 Drain pump kit

3 Filter chamber

KDU30L250VEKDU-30L125VE

2 High efficiency filterKAFJ372L280KAFP372A8065%

90%KAFP372A160

KAFJ373L280KAFP373A80 KAFP373A160KDJ3705L280KDDFP37A80 KDDFP37A160

4 Long life replacement filter KAFJ371L280KAFP371A80 KAFP371A160

TypeItem

C e ilin g s u s p e n d e d t y p eFXHQ32MA

1 Drain pump kit2 Replacement long-life filter (Resin net)

KDU50M60VEKAFJ501D56

3 L-type piping kit (for upward direction) KHFP5M35

FXHQ63MAKDU50M125VE

KAFJ501D80KHFP5M63

FXHQ100MA

KAFJ501D112

No. TypeItem

W a ll m o u n t e d t y p eFXAQ25MAFXAQ20MA

1 Drain pump kit K-KDU572CVE

FXAQ32MA FXAQ40MA FXAQ50MA FXAQ63MANo. TypeItem

F lo o r s t a n d in g t y p eFXLQ20MA

1 Long life replacement filter

FXLQ25MA FXLQ32MA FXLQ40MA FXLQ50MA FXLQ63MAKAFJ361K28 KAFJ361K45 KAFJ361K71

No. TypeItem

C o n c e a le d f lo o r s t a n d in g t y p eFXNQ20MA

1 Long life replacement filter

FXNQ25MA FXNQ32MA FXNQ40MA FXNQ50MA FXNQ63MAKAFJ361K28 KAFJ361K45 KAFJ361K71

No. TypeItem

C e ilin g s u s p e n d e d c a s s e t t e t y p eNo.

Replacement long-life filter12345

Sealing member of air discharge outlet (*1)

Decoration panel for air dischargeVertical flap kitL-shape piping kit

FXUQ71MAV1

KDBHJ49F80KDBTJ49F80KDGJ49F80

KHFP49M140

KDBHJ49F140KDBTJ49F140KDGJ49F140

FXUQ100MAV1 FXUQ125MAV1KAFJ495F140

(*1): This option is necessary for setting up 2-way (opposing directional) air flow when the air conditioner is installed.Note:

TypeItem

C e ilin g m o u n t e d b u ilt - in t y p eFXSQ20MFXSQ25MFXSQ32M

1 BYBS32DJW1KTBJ25K36W

FXSQ40MFXSQ50M

BYBS45DJW1KTBJ25K56W

FXSQ63M

BYBS71DJW1KTBJ25K80W

FXSQ80MFXSQ100M

BYBS125DJW1KTBJ25K160W

FXSQ125M

Panel related Decoration PanelAccess panel

3

KAFJ252L36KAFJ253L36

KAFJ252L56KAFJ253L56

KAFJ252L80KAFJ253L80

KAFJ252L160KAFJ253L160

Filter related

2 High efficiency filter 65% 2 High efficiency filter 90%

KAFJ251K36 KAFJ251K56 KAFJ251K80 KAFJ251K160KAJ25L36D KAJ25L56D KAJ25L80D KAJ25L160DKAJ25L36B KAJ25L56B KAJ25L80B KAJ25L160B

Long life replacement filter

KSA-25K36KBBJ25K36

KSA-25K56KBBJ25K56

KSA-25K80KBBJ25K80

KSA-25K160KBBJ25K160

Air suction canvasScreening door

KDJ2507K36 KDJ2507K56 KDJ2507K80 KDJ2507K160Air suction flangeKDAJ25K36 KDAJ25K56 KDAJ25K71 KDAJ25K140Air discharge adaptor

KNM25K32V1 KNM25K50V1 KNM25K63V1 KNM25K125V1

2 KEA25K32VE0.75

KEA25K50VE1.2

KEA25K63VE1.4

KEA25K100VE2.1

KEA25K125VE2.8

1 Auxiliary electric heater

4Air inlet and air discharge outlet related

5 Natural evaporating pan type humidifier 1 3

Capacity kW

Filter chamber

For bottom suctionFor rear suction

No.Type

Item

Note: 1 One adaptor for wiring (KRP1B61) per indoor unit is required if installing an electric heater or a natural evaporating pan type humidifier. An electric heater cannot be used for VRV system cooling only.

2 If installing a high filter in the ceiling mounted built-in type, an assembly chamber for either bottom or rear suction is required. 3 For 50 Hz models only. A special order is required for 60 Hz models.

N o r m a l T y p e s ( S p a c e S a v in g T y p e s )

No. Name of Options

1 Cool/Heat Selector KRC19–26A1-1 Fixing box

2REFNET header

REFNET joint3

KHRP26M22H (Max. 4 branch) KHRP26M22H (Max. 4 branch)KHRP26M33H (Max. 8 branch)

KHRP26M22H (Max. 4 branch), KHRP26M33H (Max. 8 branch)KHRP26M72H (Max. 8 branch)

KHRP26A22TOutdoor unit multi connection piping kit

RXQ5P RXQ8PRXQ10P

RXQ12PRXQ14PRXQ16PRXQ18P

— —

No. Name of Options

1 Cool/Heat Selector

43

1-1 Fixing box

REFNET joint

5 Central drain pan kit

Pipe size reducer

KJB111A

KHRP26A22T, KHRP26A33T, KHRP26A72TKHRP26A22T, KHRP26A33T

REFNET header2

—4 Central drain pan kit KWC26C280(E) KWC26C450(E)KWC26C160(E)5 Digital pressure gauge kit BHGP26A1

H ig h - C O P T y p e s ( E n e r g y S a v in g T y p e s )

No. Name of Options

1 Cool/Heat Selector KRC19–26A1-1 Fixing box

2REFNET header

REFNET joint

3

KHRP26M22H (Max. 4 branch)KHRP26M33H (Max. 8 branch)KHRP26M72H (Max. 8 branch)KHRP26A22T, KHRP26A33T

KHRP26A72TPipe size reducer

RXQ16PHRXQ18PH

RXQ24PHRXQ26PH

RXQ28PHRXQ30PH

RXQ32PHRXQ34PH

RXQ36PHRXQ38PHRXQ40PHRXQ42PHRXQ44PHRXQ46PHRXQ48PHRXQ50PH

KJB111A

KHRP26M22H (Max. 4 branch), KHRP26M33H (Max. 8 branch)KHRP26M72H (Max. 8 branch), KHRP26M73H (Max. 8 branch)

KHRP26A22T, KHRP26A33T, KHRP26A72T, KHRP26A73T

KHRP26M73TP, KHRP26M73HP4 Outdoor unit multi connection piping kit BHFP22P100 BHFP22P151

6 Digital pressure gauge kit BHGP26A1

5 Central drain pan kit KWC26C280(E)X2 KWC26C280(E)X3 KWC26C280(E)X2KWC26C450(E)

KWC26C280(E)KWC26C450(E)X2 KWC26C450(E)X3

Outdoor unit multi connection piping kit

Distributivepiping

O p e r a t io n c o n t r o l s y s t e m o p t io n a l a c c e s s o r ie s

Note: 1. Installation box is necessary for each adaptor marked .2. Up to 2 adaptors can be fixed for each installation box.3. Only one installation box can be installed for each indoor unit.

No.

34

FXCQ-M FXFQ-M FXKQ-MA FXSQ-MFXDQ-PFXDQ-N(A) FXAQ-MA FXLQ-MA

FXNQ-MA

Remote controllerWireless C/OWired

Simplified remote controller (Exposed type)

5 Adaptor for wiring6-1 Wiring adaptor for electrical appendices (1)6-2 Wiring adaptor for electrical appendices (2)

Remote controller for hotel use (Concealed type)

7 Remote sensor

9 External control adaptor for outdoor unit (Must be installed on indoor units)

TypeItem

BRC7C67 BRC7E65 BRC4C63 BRC4C64 BRC7E619

KRP1B59

DTA104A62

—Wired remote controller with weekly schedule timer

— KRCS01-1

KRP1B61 KRP2A62 KRP2A61 KRP4A53 KRP4A51

——

BRC4C64BRC4C64

KRP2A61KRP1B61BRC3A61BRC2C51

FXMQ-MA

BRC4C64

DTA104A61

8 Installation box for adaptor PCB Note 2,3KRP1D98 —Note 3

KRP1C93Note 2,3KRP4A93

Note 2,3KRP1B96

BRC2C51BRC3A61

KRP1B61KRP2A61KRP4A51

KRP2A62 KRP2A61 KRP4A52 KRP4A51 KRP4A51

—— Note 4,6KRP1B101

DTA104A61

FXUQ-MA

BRC7C529W

KRP2A62———

KRP1B97

KRP4A53

—DTA104A53DTA104A61 DTA104A61 DTA104A62DTA104A61

BRC1D61

FXHQ-MA

BRC7E66

—KRP1B3KRP1B56KRP2A53KRP4A54

KRP1B61KRP2A61KRP4A51

2

1

KRCS01-1Note 5KRP4A91

4. Up to 2 installation boxes can be installed for each indoor unit.5. Installation box is necessary for second adaptor.6. Installation box is necessary for each adaptor.

BRC1C62

Option List

Distributivepiping

Distributivepiping

KJB111A

KHRP26A22T, KHRP26A33T, KHRP26A72T, KHRP26A73T

KHRP26M73TP, KHRP26M73HP—

RXQ20PRXQ22P

RXQ24PRXQ26PRXQ28P

RXQ30PRXQ32PRXQ34PRXQ36P

KWC26C280(E)KWC26C450(E) KWC26C450(E)X2

BHFP22P100 BHFP22P151

6 Digital pressure gauge kit BHGP26A1

RXQ38PRXQ40PRXQ42PRXQ44PRXQ46P

RXQ48PRXQ50PRXQ52PRXQ54P

KWC26C280(E)KWC26C450(E)X2 KWC26C450(E)X3

KRC19–26A

KHRP26M22H (Max. 4 branch), KHRP26M33H (Max. 8 branch)KHRP26M72H (Max. 8 branch), KHRP26M73H (Max. 8 branch)

KHRP26A22T, KHRP26A33TKHRP26A72T

KHRP26M22H (Max. 4 branch)KHRP26M33H (Max. 8 branch)KHRP26M72H (Max. 8 branch)

Model (220 V–240 V)

Page 27: C OOLING O - Premium Serve

5251

CONTROL SYSTEM CONTROL SYSTEM

System configuration

•Up to 64 groups of indoor units (128 units) can be connected, and ON/OFF, temperature setting and monitoring can be accomplished individually or simultaneously. Connectable up to 2 controllers in one system.

Note 2,DCS302CA61Central remote controller1

•Programmed time weekly schedule can be controlled by unified control for up to 64 groups of indoor units (128 units). Can turn units ON/OFF twice per day.

Note 2DST301BA61Schedule timer3

•Up to 16 groups of indoor units (128 units) can be turned, ON/OFF individually or simultaneously, and operation and malfunction can be displayed. Can be used in combination with up to 8 controllers.

Note 2DCS301BA61Unified ON/OFF controller2

KJB212AElectrical box with earth terminal (2 blocks)2-1

KEK26-1Noise filter (for electromagnetic interface use only)2-2

KJB311AElectrical box with earth terminal (3 blocks)1-1

DTA102A52Interface adaptor for SkyAir-series4

DTA107A555

DTA103A51Wiring adaptor for other air-conditioner6

No. Part name Model No. Function

•Up to 1024 units can be centrally controlled in 64 different groups.•Wiring restrictions (max. lengh: 1,000m, total wiring lengh: 2,000m, max. number of branches: 16) apply to each adaptor.

DTA109A51D -NETExpander Adaptor

7

•Fixing plate for DTA109A51KRP4A92Mounting plate7-1

•Adaptors required to connect products other than those of the VRV System to the high-speed DIII-NET communication system adopted for the VRV System.

* To use any of the above optional c ontrollers , an appropriate adaptor must be installed on the produc t unit to be c ontrolled.

For UAT(Y)-K(A),FD-K

For SkyAir, FD(Y)M-FA, FDY-KAFDYB-KA, FDY-KA, FVY(P)J-A

Central control adaptor kit

Building management system

•Interface unit to allow communications between VRV and BMS. Operation and monitoring of air-conditioning systems through LONWORKS® communication.DMS504B514

3

•Expansion kit, installed on DMS502B51, to provide 2 more DIII-NET communication ports. Not usable independently.DAM411B513-1

•Enables ON/OFF command, operation and display of malfunction; can be used in combination with up to 4 units.DPF201A515

•Enables temperature measurement output for 4 groups; 0-5VDC.DPF201A526

•Enables temperature setting input for 16 groups; 0-5VDC.DPF201A537

No. Part name Model No. Function

*2 Interface for use in LONWORKS®

•Interface unit to allow communications between VRV and BMS. Operation and monitoring of air-conditioning systems through BACnet® communication.DMS502B51*1 Interface for use in BACnet®

Optional DIII board

Cont

act/a

nalog

uesig

nal

Parallel interfaceBasic unitTemperaturemeasurement unitsTemperaturesetting units

•Air conditioner management system that can be controlled by personal computers.DAM602B51

KJB411ADAM602B52

256 unitsDAM602B51x2512 unitsDAM602B51x3768 unitsDAM602B51x41024 unitsintelligent Manager III

128 units

2Number of units to be connected

HardwareBasic

•Expansion kit, installed on DMS502B51, to provide 16 more wattmeter pulse input points. Not usable independently.

•External temperature sensor for intelligent Manager III.

DAM412B51

DAM101A51

Optional Di board

Optional DIII Ai unit2-4

•8 pairs based on a pair of On/Off input and abnormality input.DEC101A51Di unit2-5

3-2

1-11-4

1

Electrical box with earth terminal (4 blocks)

DCS601A521-1 •Additional 64 groups (10 outdoor units) is possible.

DCS004A511-3 •Monitors and controls the air conditioning system using the Internet and a Web browser application on a PC.•Wall embedded switch box.

DCS601C51 •Air-Conditioning management system that can be controlled by a compact all-in-one unit.

Com

mun

icat

ion

line

Note : *1. BACnet® is a registered trademark of American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE).

*2. LONWORKS® is a registered trade mark of Echelon Corporation. *3. Installation box for adaptor must be procured on site.

DCS002C511-2intelligent Touch Controller

DIII-NET plus adaptor

Web

intelligent Touch Controller

P. P. D.HardwareHardware

Software

Basic

Option •P. P. D.: Power Proportional Distribution function

•4 pairs based on a pair of On/Off input and abnormality input.DEC102A51Dio unit2-6

2-1

2-2

2-3

•Power Proportional Distribution functionDAM002A51

Option Software

2-1

•Monitors and controls the air conditioning system using the Internet and a Web browser application on a PC.DAM004A512-2

•ECO (Energy saving functions.)DAM003A51

P.P.D.

Web

Eco2-3

•Interface between the central monitoring board and central control units.DCS302A528 Unification adaptor forcomputerised control

Notes: 1. Installation box for adaptor must be procured on site. 2. For FXUQ-MAV1, an interface adaptor (DTA102A52) for the SkyAir series is necessary.

Option List

Page 28: C OOLING O - Premium Serve

5453

Combine fresh air treatmentand air conditioning,supplied from a single system.

Outdoor -Air Pr oces s ing Unit

FXMQ125MFV1, FXMQ200MFV1, FXMQ250MFV1Model Numbers

Fresh air treatment and air conditioning can be achieved with a single system by using heat pump technology—without the usual troublesome air supply and air discharge balance design. Fan coil units for air conditioning andan outdoor-air processing unit can be connected to the same refrigerant line. The results are enhanced design flexibility and a significant reduction in total system costs.

Combination with VRV

Outdoor-Air Processing Unit

Indoor Unit Indoor Unit

VRV Series Outdoor Units

AirConditioning

OutdoorAir Supply

The following restrictions must be observed in order to maintain the indoor units connected to the same system.Connection Conditions

System Example

• The total connected capacity of the standard indoor units and outdoor-air processing units must be between 50% and 100% of the capacity of outdoor units. The connected capacity of the outdoor-air processing unit must not exceed 30% of the capacity of outdoor units.• An outdoor-air processing unit can be used exclusively.The connected capacity of the outdoor-air processing unit must be between 50% and 100% of the capacity of outdoor units.• Connectable outdoor units: VRV and systems

20 HP System

20 HP System

5 HPOutdoor-Air Processing Unit

5 HP Indoor Unit x 3

Check to make sure that your system’s connected capacity is within the appropriate range.

Total connected capacity of standard indoor units and outdoor-air processing unit does not exceed 100%.OK, because system capacity of 20 HP = indoor unit capacity of 20 HP.Connected capacity of outdoor-air processing unit does not exceed 30% of this.OK, because system capacity of 20 HP x 0.3 = 6 HP > outdoor-air processing unit capacity of 5 HP.

50 Hz onlyFor outdoor units of 8 HP and above

•The unit introduces outdoor air and adjusts the outdoor air temperature via fixed discharge

temperature control, thereby reducing the air conditioning load.

* The system can operate with outdoor-air temperatures ranging from -5 to 43°C. Heating performance is somewhat adversely

affected when the outdoor-air temperature is 0°C or below.* When shipped from the factory, the thermostat is set at 18°C for cooling and 25°C for heating. The set temperature can be varied

within the range of 13–25°C during cooling operation, and 18–30°C during heating operation, in the local setting mode using

the wired remote controller. The temperature, however, is not displayed on the remote controller.

* While in machine protection mode and depending on outdoor air conditions, discharge air temperature may not be at the set temperature.

* The fan stops when operating in defrosting, oil returning and hot start operations. The fan also may stop due to mechanical protection control.

• Ceiling mounted duct units with three differing capacities are available. These can be connectedto VRV series outdoor units to meet a varietyof different requirements.Air flow rate

FXMQ125MFV1FXMQ200MFV1FXMQ250MFV1 2,100 m3/h

1,680 m3/h1,080 m3/h

• The "self-diagnosis function" indicates the occur-rence and nature of abnormalities in the systemby displaying codes on the remote controller.

• Optional equipment includes long-life filters.

• Compatible with outdoor temperatures from -5°C to 43°C.

Notes1. The data shown in the graph illustrates the supported operating ranges under

the following conditions.Indoor and Outdoor UnitEffective piping length: 7.5 mHeight differential: 0 m

2. The discharge temperature can be set using the remote controller. However, the actual temperature may not match the temperature setting under some circumstances due to the outdoor-air processing load or mechanical protection controls.

3. The system will not operate in fan mode when the outdoor air temperature is 5°C or below.

• High-performance filters with dust collection efficiencies (JIS calorimetry) of 90% and 65% are also available as options.

• As with the VRV system,a variety of control systems can be deployed, including remote control from distances of up to 500 m.

* Group control is not possible between this unit and standard type indoor units. Connect remote controllers to each unit.

Wired remote controller (optional)

• A central control system compatible with the VRV system can be installed.

* It is not possible to change the discharge air temperature settings from the central control system.

* Do not associate this equipment into zones with standard indoor units,

as central control will not be possible.

Central remote controller (optional)

• As with the VRV system, the equipment employs the "super wiring system" so that the wiring linking indoor and outdoor units can also be utilised for central control.

DCS302CA61

BRC1C62

Notes:* Linked control of the product and the HRV is not supported.* This equipment is intended for the treatment of outdoor air only.

It is not to be used for maintaining indoor air temperature. Install and use with standard indoor units. Be sure to position the air discharge openings of the product in positions where the airflow will not blow on people directly. When outdoor-air processing is in excess, the unit switches to thermo-off mode, and outdoor air flows into the room directly.

* For outdoor ducts, be sure to provide heat insulation to prevent condensation.

* Group control of the product and the standard indoor units is not supported. A separate remote controller should be connected to each individual unit.

* The system will not operate in fan mode when the outdoor air temperature is 5°C or below.

* If the product is allowed to operate 24 hours a day, maintenance (part replacement, etc.) must be performed periodically.

* Temperature setting and Power Proportional Distribution (P.P.D.) are not possible even if the intelligent Touch Controller or the intelligent Manager III is installed.

* The remote controller wired to the outdoor-air processing unit must not be set as the master remote controller. Otherwise, when set to “Auto,” the operation mode will switch according to the outdoor air conditions, regardless of the indoor temperature.

–5 15 19 (33.5) 43

32

Usage Limitations

Supported Heating

Operation Range

FanOperation

Supported CoolingOperation Range

Outdoor Air T

emperature

(°CWB)

100%

Rela

tive

Humidi

ty

90% R

elativ

e Hum

idity

20% Relative

Humidity

30% Relative Humidity

Air conditioning and outdoor air processing can be accomplished using a single system.

Air Treatment Equipment Lineup

Page 29: C OOLING O - Premium Serve

5655

STANDARD SPECIFICATIONS

OPTIONS

Indoor unitType Ceiling mounted duct typeModel

Power supply

Air filter

Cooling capacity *1

Heating capacity *1

Product massSound level *3

kcal/h

FXMQ125MFV1 FXMQ200MFV1 FXMQ250MFV1V1: 1 phase 220-240V (also required for indoor units), 50 Hz

Indoor unitModel

Operation remote controllerFXMQ125MFV1 FXMQ200MFV1 FXMQ250MFV1

BRC1C62DCS302CA61DCS301BA61DST301BA61

KRP2A61KRP4A51

12,000 19,300 24,100

7,700 12,000 15,000

380X118 28 35

185 225 205*2

9.5 (flare) 15.9 (flare) 19.1 (brazing) 22.2 (brazing)

KAFJ371L140 KAFJ371L280KAFJ372L140 KAFJ372L280KAFJ373L140 KAFJ373L280KDJ3705L140 KDJ3705L280

PS1B female thread86 12342 47

RXQ8–54PY1, RXQ16–50PHY1 RXQ10–54PY1, RXQ16–50PHY1

kcal/h

Dimensions (HXWXD) 470X744X1,100 470X1,380X1,100

Btu/h 47,800 76,400 95,500kW 14.0 22.4 28.0

30,400 47,400 59,400Btu/h8.9 13.9 17.4kW

mmCasing Galvanised steel plate

WXNumber of unitsm3/min

Pa

Drain

mmmmmmkg

dB(A)

Motor output

Air flow rate635 988 1,236cfmFan

Refrigerantpiping

External static pressure *4

LiquidGas

Connectable outdoor units *5 *6Operating limit (Fan mode operation between 15 and 19°C)

19 to 43°C-5 to 15°C

CoolingHeating

Range of the discharge temperature *7 13 to 25°C18 to 30°C

CoolingHeating

Oper

ation

/cont

rol

Filte

rs

Central remote controller

Long-life replacement filterColorimetry method 65%Colorimetry method 90%

High-efficiency filterFilter chamber *1

KRP1B61Adaptor for wiring KDU30L250VEDrain pump kit

Unified ON/OFF controllerSchedule timerWiring adaptor for electrical appendices (1)Wiring adaptor for electrical appendices (2)

Notes: *1. Filter chamber has a suction-type flange. (Main unit does not.)• Dimensions and weight of the equipment may vary depending on the options used.• Some options may not be usable due to the equipment installation conditions, so please confirm prior to ordering.• Some options may not be used in combination.• Operating sound may increase somewhat depending on the options used.

Notes: *1. Specifications are based on the following conditions;• Cooling: Outdoor temp. of 33°CDB, 28°CWB (68% RH), and discharge temp. of 18°CDB. • Heating: Outdoor temp. of 0°CDB, -2.9°CWB (50% RH), and discharge temp. of 25°CDB. • Equivalent reference piping length: 7.5 m (0 m horizontal) • At 220 V.

*2. An intake filter is not supplied, so be sure to install the optional long-life filter or high-efficiency filter.Please mount it in the duct system of the suction side. Select its colorimetric method (gravity method) 50% or more.

*3. Anechoic chamber conversion value, measured at a point 1.5 m downward from the unit center.These values (measured at 220 V) are normally somewhat higher during actual operation as a result of ambient conditions.

*4. Values measured at 220 V.*5. Within the range that the total capacity of indoor units is 50 to 100%, it is possible to connect to the outdoor unit.*6. It is not possible to connect to the 5 HP outdoor unit.*7. Local setting mode. Not displayed on the remote controller.• This equipment cannot be incorporated into the remote group control of the VRV system.

DIMENSIONS

*These diagrams are based on FXMQ200 and FXM250QMFV1.

FXMQ200MFV1FXMQ125MFV1

Model Gas piping diameter

15.9

19.1 attached piping

Liquid piping diameter 9.5 9.5

Local connection piping size

1 Liquid pipe connection2 Gas pipe connection3 Drain piping connection4 Electric parts box5 Ground terminal6 Name plate

7 Power supply wiring connection8 Transmission wiring connection9 Hanger bracket

10 Discharge companion flange11 Water supply port12 Attached piping (Note. 1)

2

FXMQ250MFV1 22.2 attached piping 9.5

Table of dimensions

FXMQ200MFV1FXMQ125MFV1

Model A B C744 685 5X100=500

1380 1296 11X100=1100

D20- 4.7 hole32- 4.7 hole

FXMQ250MFV1 1380 1296 11X100=1100 32- 4.7 hole(All around)

650

or m

ore

(Ser

vice

spa

ce)

Inspection hole 600 or more

1148

1100 or more(Service space)

Appr

ox.

150

910

C

AB

D

A View

3X10

0=30

0

5047

0

Suction side (Note.2)

7601100

613

2 51 4611Discharge side

30

3

B View

360

250 3X10

0=30

033

0

B View

390

30

296

25

630

5X100=500600

20- 7 hole(All around)

8

360

200

250

346

10-M5 hole(All around)

2X200=400580

6307

61

Notes:1. The attached piping in the diagram is for FXMQ200MFV1 and FXMQ250MFV1 only. The gas piping connection port ( in the diagram) has a different bore form with FXMQ125MFV1.

2. An air filter is not supplied with this unit. Be sure to mount an air filter in the suction side.[Use a filter with dust collection efficiency of at least 50% (gravimetric method). This is available as an option.]

3. For outdoor ducts, be sure to provide heat insulation to prevent condensation.

FXMQ125MFV1

A View A View1230

11X100=11001200

245

390

30

60

296

25

360

250 3X10

0=30

033

0

32- 7 hole(All around)

12

8

1004

5X200=1000

123016-M5 hole(All around)

360

200

250

330

B View (For FXMQ250MFV1)

7

5X200=1000

1230

580

360

200

250

330

16-M5 hole(All around)

B View (For FXMQ200MFV1)

7

FXMQ200/250MFV1

FXMQ125/200/250MFV1

Air Treatment Equipment Lineup

Page 30: C OOLING O - Premium Serve

5857

The HRV Creates a High-Quality Environment by Interlocking with the Air Conditioner

306 mm

Energy Conservation

Air conditioning load reduced by approximately 30%!With a height of just 306 mm, the unit easily fits in limited spaces, such as above ceilings.

-20 -10 0 10 20 30 40 50

50˚CDB-15˚CDB 50˚CDB-15˚CDB

**For VAM500GJVE

Heat Reclaim Ventilation

VAM150GJVE, VAM250GJVE, VAM350GJVE,VAM500GJVE, VAM650GJVE, VAM800GJVE, VAM1000GJVE, VAM1500GJVE, VAM2000GJVE

Model Numbers

Indoor unitDaikin air conditioner

LCD remote controllerfor indoor unit

• Operating mode signal • Filter cleaning signal • Failure detection signal

• ON/OFF signal• Cooling/Heating mode signal• Set temperature signal• Ventilation signal• Humidifier ON/OFF signal

HRV

InterlockingInterlocking

Compact Equipment

Cold Climate Compatible

Standard operation at temperatures down to -15°C.

Improved E nthalpy E ffic iency

Higher E xternal S tatic P res s ure

E nhanced E nergy S aving F unctions

1

2

This series provides higher enthalpy efficiency , due to the greatly enhanced performance of the new ultra-thin film element. Furthermore, improved external static pressure offers more flexibility for installation. Along with these three outstanding improvements, Daikin’s exclusive function —nighttime free cooling operation—contributes to energy conservation and more comfortable space.

1

2

For models: VAM150/250/350/650/800/1000/2000GJVEFor models: VAM150/350/500GJVE2

1

Exhaustheat

Exhaustheat

The indoor accumulated heat is discharged at night.This reduces the air conditioning load the next day thereby increasing efficiency.

Indoorunit

Indoorunit

Cold air

Generatedheat

Heat is discharged. The load is small so the temperature is rapidly reducedto a comfortable level.

*Interlocked operation with an air conditioner

Comfortable!Comfortable!

This unit recovers heat energy lost through ventilation and curbs room temperature changes caused by ventilation, thereby conserving energy and reducing the load on the air conditioning system.

Molecule of waterMiscellaneous gas CO2 molecule, etc.

Sheet structure

Outdoor

Exhaust air

SA

Indoor

RA(uncleanindoor air)

Outdoor air (fresh air)

Total heat exchange ventilation

Enthalpy efficiency drastically improved by employing newly developed ultra-thin film element! (VAM-GJ model)

Thickness ofthe partition sheet

Due to the thinner film…•Decreases the moisture resistance of the partition sheets drastically.

•Realises more space for extra layers in the element, resulting in increased effective area that supply and exhaust air can be exposed to.

Moisture absorption increased by approx. 10%!

Moisture exchange efficiency is greatly improved by using optimised thinner films and moisture-absorption materials in the element. Furthermore, miscellaneous gas barrier properties are maintained by decreasing the porosity in the moisture-absorption materials.

Automatically switches the ventilation mode (Total Heat Exchange Mode/Bypass Mode) according to the operating status of the air conditioner.

Auto-ventilation ModeChangeover Switching

Reduces air conditioning load by not running the HRV while air is still clean soon after the air conditioner is turned ON.

Pre-cool,Pre-heat Control

Air conditioning sensibleheat load reduced by

approx. 5%*2

!

20% 8%

2%

• The air conditioning load reduction values are based on the following conditions;Application: Tokyo office buildingBuilding form: 2 floors above ground, 6 floors underground, floor area 2,100 m2

Personnel density: 0.25 person/m2

Ventilation volume: 25 m3/hIndoor air conditioning level: summer 25°C 50% RH, intermediate seasons 24°C 50%RH, winter 22°C 40% RHOperating time: 2745 hours (9 hours per day, approx. 25 days per month)Calculation method: simulation based on "MICRO-HASP/1982" of the JapanBuilding Mechanical and Electrical Engineers Association.

VAM-GJIndividual operation

Normalventilation fan

VAM-GJInterlocked operationwith air conditioner

Air c

ondi

tioni

ng lo

ad re

duct

ion

(%)

20%

0%

Air Conditioning LoadReduced by Approximately 30%• The air conditioning load reduction values may vary according to weather and

other environmental conditions at the location of the machine's installation.

Nighttime free cooling operation is an energy-conserving function that works at night when air conditioners are off. By ventilating rooms containing office equipment that raises the room temperature, nighttime free cooling operation reduces the cooling load when air conditioners are turned on in the morning. It also alleviates feelings of discomfort in the morning caused by heat accumulated during the night.•Nighttime free cooling operation only works to cool and if connected to Building Multi or VRV systems. •Nighttime free cooling operation is set to “off” in the factory settings, so if you wish to use it, request your dealer to turn it on. *1 This function can be operated only when interlocked with air conditioners.*2 Value is based on the following conditions:•Cooling operation performed from April to October.•Calculated for air conditioning sensible heat load only (latent heat load not included).

High-humidity air

Low-humidity air

Precise, thin-filmmaterial

Exhaust air

Supply air

Air Treatment Equipment Lineup

Air conditioning load reduced by approximately 30%!

Nighttime free cooling operation*1

OA(Fresh air fromoutdoors)

SA(Supply airto room)

EA(Exhaust air to outdoors)

RA(Return airfrom room)

Compliant with the RoHS Directive(refer to page 13 for details.)

Page 31: C OOLING O - Premium Serve

6059

Note: 1.2.3.

4.5.6.7.

8.

9.

10.

11.

Sound level is measured at 1.5m below the centre of the body. Air flow rate can be changed over to Low mode or High mode.Sound level is measured in an anechoic chamber.Sound level generally becomes greater than this value depending on the operating conditions, reflected sound, and peripheral noise.The sound level at the air discharge port is about 8 dB higher than the unit's sound level.The specifications, designs and information given here are subject to change without notice.Temperature Exchange Efficiency is the mean value between cooling and heating.Efficiency is measured under the following conditions:Ratio of rated external static pressure has been maintained as follows; outdoor side to indoor side = 7 to 1.In conformance with JIS standards (JIS B 8628), operating sound level is based on the value when one unit is operated, with the value converted for an anechoic chamber. This is transmission sound from the main unit, and does not include sound from the discharge grille. Thus it is normal for the sound to be louder than the indicated value when the unit is actually installed.Sound level from the discharge port causes the value to be approximately 8 dB (models with the air flow rate of less than 150 to 500 m3/h) to approximately 11 dB (models with the air flow rate of 650 m3/h or more) greater than the indicated value. Furthermore, fan rotation and noise from the discharge grille may increase depending on the on-site duct resistance conditions. Please consider noise countermeasures when installing the unit.With large models in particular (1500 and 2000 m3/h models), if the supply air (SA) grille is installed near the main unit, the noise of the main unit may be heard from the discharge grille via the duct, and this will result in a marked increase in noise. In such cases, if peripheral effects are included (such as reverberation of the floor and walls, combination with other equipment, and background noise), sound level may be as much as 15 dB higher than the indicated value. When installing a large model, please provide as much separation as possible between the main unit and the discharge grille. If the equipment and discharge grille are near each other, please consider countermeasures such as the following:•Use a sound-muffling box, flexible duct and sound-muffling air supply/discharge grilles•Decentralised installation of discharge grillesWhen installing in a location with particularly low background noise such as a classroom, please consider the following measures to avoid transmission sound from the main unit:•Use of ceiling materials with high sound insulating properties (high transmission loss)•Methods of blocking sound transmission, for example, by adding sound insulating materials around the bottom of the sound source.Alternatively, consider supplementary methods such as installing the equipment in a different location (corridor, etc.)

Models VAM150GJVE VAM250GJVE VAM350GJVE VAM500GJVE

Temp. Exchange Efficiency (%)[50Hz/60Hz]

Ultra-High

High

84/85 79/79

79/79 75/75

79/79 75/75

79/79 74/74

79/79 74/74

75/75 72/72

75/75 72/72

78/78 72/72

78/78 72/72

77/77

77/77

82/82 80/80.5

For HeatingEnthalpy ExchangeEfficiency (%)[50Hz/60Hz]

For Cooling

Low

72/72 71/71 70/70 67/67Ultra-High

72/72 71/71 70/70 67/67High

76/76.5 74/74 77/77 74/74.5Low

66/66 63/63 66/66 55/55Ultra-High

66/66 63/63 66/66 55/55High

70/70.5 66/66 70/70 59/59.5Low

HeatExchangeModeSound Level

dB(A)[50Hz/60Hz]

BypassMode

27-28.5/28.5 27-29/29 31.5-33/33 33-35.5/34Ultra-High

26-27.5/27.5 26-27.5/28 30-31.5/30 31.5-34/32High

20.5-21.5/21 21-22/21 23-25/23 25-28.5/24Low

28.5-29.5/29.5 28.5-30.5/30.5 33-34.5/34.5 34.5-36/35.5Ultra-High

27.5-28.5/28.5 27.5-29/29.5 31.5-33/31.5 33-34.5/33.5High

22.5-23.5/22

Galvanised steel plate

22.5-23/22.5 24.5-26.5/24.5 25.5-28.5/25.5Low

150/150 250/250 350/350 500/500Ultra-High

150/150 250/250 350/350 500/500High

100/95 155/155 230/230 320/295Low

278X810X551 306X879X800mm

24 32kg

Casing

VE: 1 phase, 220-240V/ 220V,50Hz/ 60HzPower Supply

Self-extinguishable polyurethane foamInsulation Material

Air to air cross flow total heat (Sensible heat + latent heat) exchangeHeat Exchange System

Specially processed nonflammable paperHeat Exchange Element Material

Multidirectional fibrous fleecesAir Filter

Sirroco fanType

Fan

Dimensions (HXWXD)

Weight

0.030X2 0.090X2kW

100 150 200mm

-15°C~+50°CDB, 80%RH or lessUnit ambient condition

Motor Output

Connection Duct Diameter

Air Flow Rate (m3/h)[50Hz/60Hz]

120/154 70/96 169/222 105/150Ultra-High

106/131 54/65 141/145 66/52High

56/60 24/20 67/30 32/18Low

External Static Pressure (Pa)[50Hz/60Hz]

VAM650GJVE VAM800GJVE VAM1000GJVE VAM1500GJVE

77/77.5 74/74.5 80.5/81 75.5/76

67.5/67.5 65/65 70/70 65/65

67.5/67.5 65/65 70/70 65/65

71.5/72 67.5/68 72.5/73 67/67.5

61/61 61/61 64/64 61/61

61/61 61/61 64/64 61/61

64/64.5 64/64.5 68.5/69 64/64.5

34-36/36 39-40.5/39.5 39.5-41.5/39.5 39.5-41.5/41.5

33-34.5/34 37-39.5/37.5 37.5-39.5/37.5 37.5-39.5/39.5

27.5-29.5/28 35-37.5/34 35-37.5/34.5 35-37.5/36

35-37.5/37.5 40.5-42/41 40.5-42.5/40.5 41-43/42.5

33-35.5/35.5 38.5-40/39 38.5-40.5/38.5 39.5-41/41.5

27.5-30.5/29.5 36-38.5/35.5 36-38.5/35.5 36.5-38/37.5

650/650 800/800 1,000/1,000 1,500/1,500

650/650 800/800 1,000/1,000 1,500/1,500

500/470 700/670 860/840 1,320/1,260

387X1,111X1,214387X1,111X832338X973X832

45 55 67

785X1,619X832 785X1,619X1,214

129

0.140X2 0.280X2 0.280X4

250 350

85/125 133/170 168/192 112/150

53/67 92/85 110/86 73/72

35/38 72/61 85/60 56/50

VAM2000GJVE

79/81

72/72

72/72

75/76

62/62

62/62

66/67

41.5-43.5/42

39-43/40

36-39/39

43-45.5/44

40.5-45/42

37.5-39.5/41

2,000/2,000

2,000/2,000

1,720/1,580

157

116/140

58/32

45/45

For wiring

Option List

Silencer

VAM150GJVE VAM250GJVE VAM350GJVE VAM500GJVE VAM650GJVE VAM800GJVE VAM1000GJVE VAM1500GJVE VAM2000GJVE——

KDDM24B50 KDDM24B100 KDDM24A100X2 200 250

Air suction/discharge grille (Field supply)

Branch duct(Field supply)

SA

SA

RA

EAOA

Duct(Field supply)

Flexible duct(Option)

Silencer (Option)

Round hood(Field supply)

Thermal insulation material (Field supply)

High efficient filter(Option)

Nominal pipe diameter (mm)

Member Applicable model

Addi

tiona

lfu

nctio

n

Central remote controllerHRV remote controller

Wiring adaptor for electrical appendices

Installation box for adaptor PCB

Type (indoor unit of VRV)

Installation box for adaptor PCB

Unified ON/OFF controllerSchedule timer

For humidifier

For heater control kit

BRC301B61DCS302CA61DCS301BA61DST301BA61

KRP2A61KRP50-2

BRP4A50KRP50-2A90 (Mounted electric component assy of HRV)

FXCQ-M FXKQ-MAFXFQ-M FXSQ-M FXHQ-MA FXAQ-MA FXLQ-MAFXNQ-MAFXMQ-MA

KRP1B61 KRP1B59 KRP1B61—Note 2, 3KRP1B96 —Note 2, 3

KRP1D98Note 5KRP4A91

FXDQ-PFXDQ-N(A)

Note 4, 6KRP1B101 —

Member Applicable model

Con

trollin

g de

vice

PC B

oard

Ada

ptor

Centralised controlling device

Note: 1.2.3.

Installation box is necessary for each adaptor marked . Up to 2 adaptors can be fixed for each installation box.Only one installation box can be installed for each indoor unit.

High efficiency filter

Flexible duct (1m)Flexible duct (2m)Duct adaptor

KAF242G25M KAF242G50M KAF242G65M KAF242G80MKAF241G65M KAF241G80M

KAF242G100M KAF242G80MX2 KAF242G100MX2Air filter for replacement KAF241G25M KAF241G50M KAF241G100M KAF241G80MX2 KAF241G100MX2

K-FDS101C K-FDS151C K-FDS201C K-FDS251CK-FDS102C K-FDS152C K-FDS202C K-FDS252C

——

YDFA25A1 250Nominal pipe diameter (mm)

KRP1B3—

FXUQ-MA

—KRP1B97Note 2, 3

KRP4A93Note 3KRP1C93

KRP1B61KRP1B61 KRP1B56

4.5.6.

Up to 2 installation boxes can be installed for each indoor unit.Installation box is necessary for second adaptor.Installation box is necessary for each adaptor.

SPECIFICATIONS OPTIONS

Air Treatment Equipment Lineup

EA

OA

RA

SA

Power supply (Field supply)Relay box

Temperature thermo. (Field supply)(ON when the temperature is at or below -10°C)

HRVHeater

control kit(Field supply)

BRP4A50

Temperature thermo. (Field supply)(OFF when the temperature is at or more than 5°C)

Indoor Outdoor

When the installation of an electric heater is required in a cold region, this adaptor with an internal timer function eliminates the complicated timer connecting work that was necessary with conventional heaters.

Examine fully an installation place and specification for using the electric heater based on the standard and regulation of each country.Supply the electric heater and safety production devices such as a relay and a thermostat, etc of which qualities satisfy the standerd and regulation of each country at site.Use a non-inflammable connecting duct to the electric heater. Be sure to allow 2 m or more between the electric heater and HRV for safty.For the HRV units, use a different power supply from that of the electric heater and install a circuit breaker for each.

Notes when installing

PC board adaptor for heater control kit (BRP4A50)

Page 32: C OOLING O - Premium Serve