A - AMPERES AC - ABOVE COUNTER AFF - ABOVE FINISHED FLOOR AWG - AMERICAN WIRE GAUGE C - CONDUIT CAT - CATALOG CB - CIRCUIT BREAKER CCTV - CLOSED CIRCUIT TELEVISION CKT - CIRCUIT CL - CENTER LINE CLG - CEILING COND - CONDUCTOR CU - COPPER DVR - DIGITAL VIDEO RECORDER DWG - DRAWING EC - EMPTY CONDUIT EM - EMERGENCY EX - EXISTING FA - FIRE ALARM FACP - FIRE ALARM CONTROL PANEL G - GROUND HC - HUNG CEILING HZ - HERTZ IDF - INTERMEDIATE DISTRIBUTION FRAME JB - JUNCTION BOX LV - LOW VOLTAGE MAX - MAXIMUM MDF - MAIN DISTRIBUTION FRAME MER - MECHANICAL EQUIPMENT ROOM MIN - MINIMUM MTD - MOUNTED MTG - MOUNTING MTS - MANUAL TRANSFER SWITCH N - NEUTRAL NC - NORMALLY CLOSED NIC - NOT IN CONTRACT NO - NORMALLY OPEN No. - NUMBER NTS - NOT TO SCALE PA - PUBLIC ADDRESS PNL - PANEL POE - POWER OVER ETHERNET PTZ - PAN/TILT/ZOOM RM - ROOM MTG - MOUNTING MTS - MANUAL TRANSFER SWITCH N - NEUTRAL NC - NORMALLY CLOSED NIC - NOT IN CONTRACT NO - NORMALLY OPEN No. - NUMBER NTS - NOT TO SCALE PA - PUBLIC ADDRESS PNL - PANEL POE - POWER OVER ETHERNET
1. DRAWINGS ARE NOT TO BE USED FOR ARCHITECTURAL OR ENGINEERING PURPOSES. THE SECURITY DRAWINGS SHOULD ONLY BE USED FOR SECURITY SYSTEMS INSTALLATION AND COORDINATION.
2. ALL MOUNTING SPECIFICS SHALL BE AS INDICATED IN THE LEGEND UNLESS OTHERWISE NOTED IN THE SECURITY DRAWINGS. MOUNTING CONDITIONS IDENTIFIED ON THE SECURITY DRAWINGS SHALL TAKE PRECEDENCE OVER THE LEGEND DESACIPTIONS.
3. VERIFY AND COORDINATE THE EXACT MOUNTING LOCATION OF ALL DEVICES PRIOR TO INSTALLATION.
4. THE MOUNTING HEIGHTS ARE TO THE CENTERLINE OF THE DEVICE UNLESS OTHERWISE NOTED.
5. THE SECURITY CONTRACTOR SHALL RESTORE CEILINGS AND WALLS AND ANY OTHER SURFACES AFFECTED BY HIS WORK WITH LIKE MATERIALS TO MATCH EXISTING CONSTRUCTION UPON COMPLETION OF HIS WORK.
6. FIRE STOPPING OF ALL PENETRATIONS SHALL BE PROVIDED BY THE SECURITY CONTRACTOR AS REQUIRED BY CODE.
7. ALL DEVICES, WIRING, TERMINATIONS, AND OTHER REQUIRED ROUGH-IN NOT DESIGNATED "BY OTHERS" ARE TO BE PROVIDED BY THE SECURITY CONTRACTOR.
8. COORDINATE ALL EXTERIOR CAMERA LOCATIONS WITH THE LANDSCAPE TO ENSURE THAT CAMERA VIEW ARE NOT OBSTRUCTED.
1. ALL CONDUIT AND BACKBOXES SHALL CONFORM TO BUILDING STANDARD ELECTRICAL SPECIFICATIONS. ALL CABLES SHALL BE PLENUM RATED WHERE REQUIRED.
2. ALL CONDUIT SHALL BE 3/4" UNLESS OTHERWISE NOTED.
3. ALL CONDUIT USED IN POTENTIALLY DAMP OR WET LOCATIONS, EXPOSED OUTDOORS, OR IN HAZARDOUS AREAS SHALL BE INTERMEDIATE STEEL CONDUIT (IMC). ALL EXTERIOR CONDUIT IN SLAB SHALL BE PVC. ALL CONDUIT OTHER THAN SPECIFIED TO BE IMC OR PVC SHALL BE ELECTRICAL METALLIC TUBING (EMT).
4. ALL CONDUIT SHALL BE ROUTED ABOVE CEILINGS, BELOW FLOORS, OR WITHIN WALLS. NO CONDUIT SHALL BE EXPOSED UNLESS APPROVED BY THE ARCHITECT.
5. PROVIDE PULL STRINGS IN ALL CONDUIT AND PULLBOXES AS REQUIRED. ALL CONDUITS SHALL HAVE PLASTIC BUSHINGS INSTALLED AT OPEN ENDS PRIOR TO PULLING WIRE.
6. ALL BACKBOXES SHALL BE FLUSH MOUNTED UNLESS OTHERWISE NOTED.
7. ALL BACKBOXES MOUNTED WITHIN FIRE RATED PARTITIONS SHALL MEET THE FIRE RATING OF THE PARTITION AS REQUIRED BY CODE.
8. COORDINATE THE EXACT LOCATION OF ALL PULL AND BACKBOXES WITH ARCHITECTURAL, ELECTRICAL, AND MECHANICAL DRAWINGS.
9. ALL JUNCTION AND PULLBOXES SHALL BE PROVIDED WITH ACCOMPANYING BLANK COVER PLATE.
10. JUNCTION BOXES LOCATED ABOVE DOORS WITH NO ACCESSIBLE CEILING SHALL BE SECURED WITH TAMPER PROOF SCREWS.
11. PROVIDE WATERTIGHT SEALING ASSEMBLIES WITH PRESSURE BUSHING AS REQUIRED FOR EXTERIOR PENETRATIONS.
12. JUNCTION AND PULLBOXES IN EXTERIOR LOCATIONS SHALL BE WATERPROOF.
13. ALL CABLE RUNS IN CEILING AREAS WHERE CONDUIT OR CABLE TRAY IS NOT SPECIFIED SHALL BE SUPPORTED WITH SIMILAR SUPPORT OR WITH THE USE OF J-HOOKS AT 5' INTERVALS ABOVE CEILING TILES.
14. COORDINATE WITH DESIGN BUILD CONTRACTOR FOR SECURITY DEVICE AND CONTROL PANEL POWER REQUIREMENTS.
15. WIRE SHEATH SHALL BE MAINTAINED TO FINAL TERMINATION. ALL TERMINATIONS SHALL MAINTAIN TWIST OF INDIVIDUAL PAIRS TO WITHIN 0.5" OR LESS OF FINAL TERMINATION. ALL WIRES SHALL BE LABELED WITHIN 6.5" OF FINAL TERMINATION. ALL LABELS SHALL BE
MACHINE PRINTED OR STENCILED. NO HAND LETTERED LABELS SHALL BE USED.
16. ANY CONDUIT ROUTING SHOWN IS SCHEMATIC AND IS NOT INTENDED TO REPRESENT INSTALLED PATHS OR DISTANCES. ACTUAL ROUTING AND BOX LOCATIONS SHALL BE FIELD VERIFIED AND COORDINATED WITH OTHER DISCIPLINES BY THE INSTALLING CONTRACTOR.
1.SECURITY DEVICES AND WIRING SHALL BE PROVIDED BY OTHERS AND ARE SHOWN FOR COORDINATION ONLY. DESIGN BUILD TEAM SHALL CONTINUE TO SHOW FOR COORDINATION. CONDUIT, BOXES, PULL STRINGS, AND OTHER REQUIRED ROUGH-IN SHALL BE PROVIDED BY THE DESIGN BUILD CONTRACTOR.
2.SECURITY DEVICES AND WIRING PROVIDED BY OTHER ARE SHOWN FOR COORDINATION ONLY. DESIGN BUILD TEAM SHALL CONTINUE TO SHOW FOR COORDINATION. NOTES BELOW INDICATE WORK BY THE DESIGN BUILD CONTRACTOR.
3.PROVIDE 4" X 4" X 2-1/4" DEEP BOX WITH SINGLE GANG DEVICE RING JB FLUSH MOUNTED 48" A.F.F WITH 3 /4" CONDUIT STUBUP TO J1 BY DESIGN BUILD CONTRACTOR.
4.STUB 3/4" CONDUIT OR GREENFIELD DOWN DOOR FRAME ON THE HINGE SIDE OF THE DOOR BACK BOX EL TO JUNCTION BOX J1 LOCATED ABOVE ACCESSIBLE CEILING, BY DESIGN BUILD CONTRACTOR.
5.STUB 3/4" CONDUIT OR GREENFIELD DOWN DOOR FRAME ON THE STRIKE SIDE OF THE DOOR ES TO JUNCTION BOX J1 LOCATED ABOVE ACCESSIBLE CEILING, BY DESIGN BUILD CONTRACTOR.
DEVICE
DETAIL NUMBER
DETAIL NUMBER
DEVICE TYPECAM = CCTV CAMERA
DEVICE TYPE
LEVEL
DEVICE
RISER POWER (EMERGENCY CIRCUIT) DESIGN BUILD CONTRACTOR TO PROVIDE A HARD WIRED CONNECTION TO A 120VAC 20A EMERGENCY CIRCUIT DEDICATED TO SECURITY IN EACH RISER LOCATION WITHIN A 4" X 4" BOX SURFACE MOUNTED 18" A.F.F. WITH WIRE ENDS TERMINATED AND INSULATED WITH WIRE NUTS
RISER POWER (NON-EMERGENCY CIRCUIT) DESIGN BUILD CONTRACTOR TO PROVIDE A HARD WIRED CONNECTION TO A 120VAC 20A NON-EMERGENCY CIRCUIT DEDICATED TO SECURITY IN EACH RISER LOCATION WITHIN A 4" X 4" BOX SURFACE MOUNTED 18" A.F.F. WITH WIRE ENDS TERMINATED AND INSULATED WITH WIRE NUTS.
SECURITY CONTROL/EQUIPMENT ROOM POWER (EMERGENCY CIRCUIT) DESIGN BUILD CONTRACTOR TO PROVIDE A HARD WIRED CONNECTION TO A 120VAC 20A UNINTERRUPTIBLE POWER CIRCUIT DEDICATED TO SECURITY WITHIN A 4" X 4" BOX SURFACE MOUNTED BEHIND THE CONSOLE/RACK AT 18" AFF WITH WIRE ENDS TERMINATED AND INSULATED WITH WIRE NUTS.
MAGNOTOMETER/X-RAY SCANNER POWER (NON-EMERGENCY CIRCUIT) DESIGN BUILD CONTRACTOR SHALL PROVIDE AN UN-SWITCHED DUPLEX OUTLET CONNECTED TO A 120VAC 20A NON-EMERGENCY CIRCUIT DEDICATED TO SECURITY. THE OUTLET SHALL BE FLUSH MOUNTED IN THE FLOOR.
EXTERIOR CAMERA POWER (NON-EMERGENCY CIRCUIT) DESIGN BUILD CONTRACTOR SHALL PROVIDE A HARD WIRED CONNECTION TO A 120VAC 20A NON-EMERGENCY CIRCUIT DEDICATED TO SECURITY. THE CIRCUIT CONNECTION SHALL BE PROVIDED WITHIN A 4" X 4" BOX MOUNTED ABOVE ACCESSIBLE CEILING ON INTERIOR OF BUILDING WITH WIRE ENDS TERMINATED INSULATED WITH WIRE NUTS. MULTIPLE CONNECTIONS CAN BE BRANCHED OFF THIS CIRCUIT FOR ADDITIONAL CAMERAS BUT SHALL NOT EXCEED 2 CONNECTIONS TOTAL. EACH CAMERA'S ACTUAL LOAD SHALL BE 5A AT 120VAC. FOR EXTERIOR LOCATION PROVIDE POWER IN 4"X4"OUTDOOR RATED BOX
POLE MOUNTED CAMERA POWER (NON-EMERGENCY CIRCUIT) DESIGN BUILD CONTRACTOR SHALL PROVIDE A HARD WIRED CONNECTION TO A 120VAC 20A NON-EMERGENCY CIRCUIT DEDICATED TO SECURITY PROVIDED WITHIN A NEMA 4X ENCLOSURE MOUNTED AT THE BASE OF THE POLE WITH WIRE ENDS TERMINATED AND INSULATED WITH WIRE NUTS. MULTIPLE CONNECTIONS CAN BE BRANCHED OFF THIS CIRCUIT FOR ADDITIONAL CAMERAS BUT SHALL NOT EXCEED 15 CONNECTIONS TOTAL. EACH CAMERA'S ACTUAL LOAD SHALL BE 1A AT 120VAC.
ELECTRIC EXIT DEVICE POWER (EMERGENCY CIRCUIT) DESIGN BUILD CONTRACTOR SHALL PROVIDE A HARD WIRED CONNECTION TO A 120VAC 20A EMERGENCY CIRCUIT DEDICATED TO SECURITY AT DOORS UTILIZING ELECTRIC EXIT DEVICES PROVIDED WITHIN A 4" X 4" BOX MOUNTED ABOVE ACCESSIBLE CEILING ADJACENT TO THE DOOR OR AS SHOWN ON DRAWINGS WITH WIRE ENDS TERMINATED AND INSULATED WITH WIRE NUTS. MULTIPLE CONNECTIONS CAN BE BRANCHED OFF THIS CIRCUIT FOR ADDITIONAL ELECTRIC EXIT DEVICES BUT SHALL NOT EXCEED 10 CONNECTIONS TOTAL. EACH DEVICE'S ACTUAL LOAD SHALL BE 1.5A AT 120VAC.
X-RAY/METAL DETECTOR POWER (EMERGENCY CIRCUIT) DESIGN BUILD CONTRACTOR SHALL PROVIDE AN UN-SWITCHED DUPLEX OUTLET TO A 120VAC 20A EMERGENCY CIRCUIT DEDICATED TO SECURITY. THE OUTLET SHALL BE FLUSH MOUNTED IN FLOOR.
ELEVATOR SECURITY EQUIPMENT POWER (NON-EMERGENCY CIRCUIT) DESIGN BUILD CONTRACTOR SHALL PROVIDE A HARD WIRED CONNECTIONS TO A 120VAC 20A NON-EMERGENCY CIRCUIT DEDICATED TO SECURITY IN THE ELEVATOR MACHINE ROOM(S) AS INDICATED ON THE DRAWINGS. TYPICAL LOAD FOR EACH CIRCUIT SHALL BE 10A. PROVIDE CONNECTION IN A SURFACE MOUNTED BOX MOUNTED AT 8' A.F.F. WITH WIRE ENDS TERMINATED AND INSULATED WITH WIRE NUTS
UPS POWER (EMERGENCY CIRCUIT) DESIGN BUILD CONTRACTOR SHALL PROVIDE A HARD WIRED CONNECTION TO A 240VAC 65A EMERGENCY CIRCUIT DEDICATED TO SECURITY AS INDICATED ON THE DRAWINGS. THE CONNECTION SHALL BE PROVIDED WITHIN A 4" X 4" BOX SURFACE MOUNTED IN THE BACK OF THE SECURITY EQUIPMENT RACK, 18" A.F.F. AND SHALL HAVE WIRE ENDS TERMINATED AND INSULATED WITH WIRE NUTS.
VEHICLE GATE POWER (EMERGENCY CIRCUIT) DESIGN BUILD CONTRACTOR SHALL PROVIDE A DEDICATED 120V AC HARD WIRED 20AMP CIRCUIT WITHIN THE GATE HOUSING. THE JUNCTION BOX SHALL BE OUTDOOR RATED. THE DESIGN BUILD CONTRACTOR SHALL PROVIDE SURGE PROTECTION FOR THE CIRCUIT EACH GATE SHOULD HAVE A DEDICATED CIRCUIT MULTIPLE GATES SHOULD NEVER SHARE CIRCUIT.
SITE POWER (NON-EMERGENCY CIRCUIT) DESIGN BUILD CONTRACTOR SHALL PROVIDE AN UN-SWITCHED DUPLEX OUTLET TO A 120VAC 20A NON-EMERGENCY CIRCUIT DEDICATED TO SECURITY. THE OUTLET SHALL BE WALL MOUNTED 12" AAF.
ELECTRIC EXIT DEVICE POWER (NON-EMERGENCY CIRCUIT) DESIGN BUILD CONTRACTOR SHALL PROVIDE A HARD WIRED CONNECTION TO A 120VAC 20A UN-SWITCHED CIRCUIT DEDICATED TO SECURITY AT DOORS UTILIZING ELECTRIC EXIT DEVICES PROVIDED WITHIN A 4" X 4" BOX MOUNTED ABOVE ACCESSIBLE CEILING ADJACENT TO THE DOOR OR AS SHOWN ON DRAWINGS WITH WIRE ENDS TERMINATED AND INSULATED WITH WIRE NUTS. MULTIPLE CONNECTIONS CAN BE BRANCHED OFF THIS CIRCUIT FOR ADDITIONAL ELECTRIC EXIT DEVICES BUT SHALL NOT EXCEED 10 CONNECTIONS TOTAL. EACH DEVICE'S ACTUAL LOAD SHALL BE 1.5A AT 120VAC.
SECURITY EMERGENCY CALL STATION POWER (EMERGENCY CIRCUIT) HARD WIRE TO 120VAC 20A CIRCUIT EMERGENCY CIRCUIT DEDICATED FOR EMERGENCY CALL STATIONS. MOUNTING HT OF CALL BOX TO BE 36" AFF TO BOTTOM OF UNIT. POWER TO BE BROUGHT DOWN IN COLUMN TO 4" X 4" BOX TO ALIGN WITH 3/4" KO ON BACK OF UNIT. 5 UNITS CAN BE POWERED FROM SAME CIRCUIT.
ELEVATOR CAMERA POWER (NON-EMERGENCY CIRCUIT) ELEVATOR CONTRACTOR SHALL PROVIDE AN UN-SWITCHED DUPLEX OUTLET TO A 120VAC 20A NON-EMERGENCY CIRCUIT DEDICATED FOR THE SECURITY CAMERA. THE OUTLET SHALL BE MOUNTED ABOVE THE CAB AND PROVIDE ADEQUATE SPACE FOR A PLUG IN TYPE TRANSFORMER.
INTERIOR PTZ CAMERA POWER (NON-EMERGENCY CIRCUIT) DESIGN BUILD CONTRACTOR SHALL PROVIDE A HARD WIRED CONNECTION TO A 120VAC 20A NON-EMERGENCY CIRCUIT DEDICATED TO SECURITY. THE CIRCUIT CONNECTION SHALL BE PROVIDED WITHIN A 4" X 4" BOX MOUNTED ABOVE ACCESSIBLE CEILING ON INTERIOR OF BUILDING WITH WIRE ENDS TERMINATED INSULATED WITH WIRE NUTS. MULTIPLE CONNECTIONS CAN BE BRANCHED OFF THIS CIRCUIT FOR ADDITIONAL CAMERAS BUT SHALL NOT EXCEED 2 CONNECTIONS TOTAL. EACH CAMERA POWER SUPPLY ACTUAL LOAD SHALL NOT EXCEED 3A AT 120VAC.
ACCESS CONTROL READER
ACCESS CONTROL PANEL
ACCESS CONTROL SERVER
ANNUNCIATOR
ALARM PANEL
DOOR INTERLOCK
DOOR INTERFACE UNIT
DOOR POSITION SWITCH
DIGITAL VIDEO RECORDER
ELECTRIC LOCK
HEAD END MONITORING LOCATION
INTERCOM
INFRARED BEAM
ALARM KEYPAD
FIRE RELAY (FOR LOCK RELEASE)
LOCAL ALARM
MAGNETIC CONTACT
MOTION DETECTOR
MAGNETIC HOLD OPEN
VIDEO SURVEILLANCE
NETWORK VIDEO RECORDER
PUSH BUTTON
REQUEST TO EXIT
RELAY IN/OUT
SECURITY BADGE PRINTER
SECURITY RISER LOCATION
SIREN/SOUNDER
STROBE
VIDEO INTERCOM
VIDEO ENCODER
VIBRATION SENSOR
WORKSTATION
LOCK POWER SUPPLY
CAMERA POWER SUPPLY
DEVICE POWER SUPPLY
CCTV CAMERA - FIXED
CCTV CAMERA - PTZ
CCTV CAMERA - CEILING MOUNT
CCTV CAMERA - WALL MOUNT
CCTV CAMERA - CORNER MOUNT
CCTV CAMERA - CORNER MOUNT
PROVIDE 4" X 4" X 2-1/4" DEEP BOX SURFACE MOUNTED ABOVE ACCESSIBLE CEILING UNLESS OTHERWISE NOTED.
PROVIDE 6" X 6" X 4" DEEP BOX SURFACE MOUNTED ABOVE ACCESSIBLE CEILING UNLESS OTHERWISE NOTED.
PROVIDE 10" X 10" X 4" DEEP BOX SURFACE MOUNTED ABOVE ACCESSIBLE CEILING UNLESS OTHERWISE NOTED.
PROVIDE 12" X 12" X 6" DEEP BOX SURFACE MOUNTED ABOVE ACCESSIBLE CEILING UNLESS OTHERWISE NOTED.
PROVIDE 16" X 16" X 8" DEEP BOX SURFACE MOUNTED ABOVE ACCESSIBLE CEILING UNLESS OTHERWISE NOTED.
PROVIDE 20" X 20" X 8" DEEP BOX SURFACE MOUNTED ABOVE ACCESSIBLE CEILING UNLESS OTHERWISE NOTED.
01
02
03
04
05
06
07
08
09
10
11
12
13
14
15
16
XX-XXX
DEVICE TYPE
AC-X
DETAIL NUMBER
LEVEL DEVICE NUMBER
DRAWING LIST: ABBREVIATIONS: SECURITY ELECTRICAL NOTES: SYMBOLS: GENERAL NOTES:
SECURITY CONDUIT AND WIRING NOTES:
EQUIPMENT SYMBOL & TAG DEFINITIONS:
SECURITY DEVICE NOTES:
PTZ - PAN/TILT/ZOOM RM - ROOM STP - SHIELDED TWISTED PAIR XFRM - TRANSFORMER TEL - TELECOMMUNICATIONS TLR - TIME LAPSE RECORDER TS - TAMPER SWITCH TTB - TELECOM TERMINAL BOARDTTC - TELECOM TERMINAL CABINET TV - TELEVISION TYP - TYPICAL UON - UNLESS OTHERWISE NOTED UPS - UNINTERRUPTIBLE POWER SUPPLY UTP - UNSHIELDED TWISTED PAIR V - VOLTS VA - VOLT-AMPERES VM - VOLTMETER VP - VAPOR PROOF W - WATTS WP - WATERPROOF WT - WATERTIGHT
MO
SE
LE
YA
RC
HIT
EC
TS
.CO
M
PROJECT NO:DATE:
320
0 N
OR
FO
LK
ST
RE
ET
, R
ICH
MO
ND
, V
A 2
323
0
PH
ON
E (
80
4)
79
4-7
555
F
AX
(8
04
) 3
55
-569
0
A
B
C
D
E
1 2 4 53 6 7 8 9 10
F
G
H
I
J
3/3
1/2
02
0 4
:46:2
4 P
M
SECURITY LEGEND
CIT
Y O
F V
IRG
INIA
BE
AC
H
BU
ILD
ING
11
RE
NO
VA
TIO
N
Pro
ject
Ad
dre
ss
TY0.0.0
PW
CN
-18-
0156
CIP
-3-1
74
548507MARCH 31, 2020
NUMBER NAME
TY0.0.0 SECURITY LEGEND
TY1.1.0 SECURITY OVERALL PLAN LOWER
TY1.2.0 SECURITY OVERALL PLAN FIRSTFLOOR
TY1.3.0 SECURITY OVERALL PLAN SECONDFLOOR
TY5.0.1 SECURITY DETAILS
REVISIONS
DATE DESCRIPTION
REF.
FEC
CR
C - 2
CR
CR
CR
CR
CR
C -
2
C - 2
CR
CR
CR
C -
2
360 C - 4
360 C - 4
360 C - 4
CR
CR CR
CR
360 C - 4
CR
CR
CR
DPS_EL_RX
DPS_EL_RXDPS_EL_RXDPS_EL_RX
DPS_EL_RX
DPS_EL_RX
DC
2 DPS_EL_RX
2 DPS_EL_RX
2 DPS_EL_RX
DPS_EL_RX
DPS_EL_RX
DPS_EL_RX
DPS_EL_RX
Room
051
PRINT SHOP
007
Room
50
Room
51
STAFF TOILET
020
CIRCULATION
002
STAIR
006OPEN OFFICE
003
OPEN OFFICE
024
OPEN OFFICE
030
CONFERENCE ROOM
047
MECHANICAL ROOM
044
STAIR
001
PHONE BOOTH
038
BOOT WASH
043
CONFERENCE ROOM
048
WORKROOM
023
IT SERVER
045
1:1 CONFERENCE
029
STAFF TOILET
021
ELECTRICAL
046
HOUSEKEEPING
041
LACTATION
042
ASSET RECOVERY
005
PLUMBING ACCESS
252
ELEVATOR
049
ELEV EQUIP
022
TIER 1 CALL CENTER
011
NOC
015
ITAC
016
INFO SEC
017
CA SUPERVISOR
013
CONVERGENT ARCHITECTURE LAB
014
SYSTEMS ENGINEER I
004
PRINT ROOM - STAFF
008
ASSET RECOVERY - STAFF
009
SOLUTIONS ENGINEERSUPERVISOR
010
OPS MANAGER
012
INFO SEC MGR
018
DIVISION MANAGER
025
INSPECTION COORDINATOR II
026
CONSTRUCTION BUREAU MANAGER
027
STORAGE
028
SURVEY TECHNICIAN
031
CITY SURVEYOR
033
STORAGE
035
CREW ROOM
036
STORAGE
037
BREAK ROOM
019
1:1 CONFERENCE
032
PHONE BOOTH
039PHONE BOOTH
040
W - 1
0101
04
2 DPS_EL_RX
2 DPS_EL_RX
DPS_EL_RX
NOTE: SECURITY DEVICES AND WIRING SHALL BE PROVIDED BY OTHERS AND ARE SHOWN FOR COORDINATION ONLY. DESIGN BUILD TEAM SHALL CONTINUE TO SHOW FOR COORDINATION. CONDUIT, BOXES, PULL STRINGS, AND OTHER REQUIRED ROUGH-IN SHALL BE PROVIDED BY THE DESIGN BUILD CONTRACTOR.
NOTE: DEMOUNTABLE PARTITIONS AND DOORS SHOWN DASHED FOR INFORMATION AND COORDINATION PURPOSES ONLY, NIC. REFER TO THE FURNITURE DRAWINGS AND THE PROJECT MANUAL PREAMBLE-ALTERNATES AND UNIT PRICING FOR ADDITIONAL INFORMATION
MO
SE
LE
YA
RC
HIT
EC
TS
.CO
M
PROJECT NO:DATE:
320
0 N
OR
FO
LK
ST
RE
ET
, R
ICH
MO
ND
, V
A 2
323
0
PH
ON
E (
80
4)
79
4-7
555
F
AX
(8
04
) 3
55
-569
0
A
B
C
D
E
1 2 4 53 6 7 8 9 10
F
G
H
I
J
3/3
1/2
02
0 4
:46:2
7 P
M
SECURITY OVERALL
PLAN LOWER
CIT
Y O
F V
IRG
INIA
BE
AC
H
BU
ILD
ING
11
RE
NO
VA
TIO
N
Pro
ject
Ad
dre
ss
TY1.1.0
PW
CN
-18-
0156
CIP
-3-1
74
548507MARCH 31, 2020
1/8" = 1'-0"1
SECURITY OVERALL PLAN LOWER
REVISIONS
DATE DESCRIPTION
SECURITY KEYNOTE LEGEND
NUMBER DESCRIPTION
01 RISER POWER (EMERGENCY CIRCUIT) DESIGN BUILDCONTRACTOR TO PROVIDE A HARD WIREDCONNECTION TO A 120VAC 20A EMERGENCY CIRCUITDEDICATED TO SECURITY IN EACH RISER LOCATIONWITHIN A 4" X 4" BOX SURFACE MOUNTED 18" A.F.F.WITH WIRE ENDS TERMINATED AND INSULATED WITHWIRE NUTS.
04 SECURITY CONTROL/EQUIPMENT ROOM POWER(EMERGENCY CIRCUIT) DESIGN BUILD CONTRACTORTO PROVIDE A HARD WIRED CONNECTION TO A 120VAC20A UNINTERRUPTIBLE POWER CIRCUIT DEDICATED TOSECURITY WITHIN A 4" X 4" BOX SURFACE MOUNTEDBEHIND THE CONSOLE/RACK AT 18" AFF WITH WIREENDS TERMINATED AND INSULATED WITH WIRE NUTS.
REF.REF.
DN
DN
C - 17
C -
17
C -
17 C - 17
C - 17
C -
17
C - 2
CR
CR
CR
CR
CR
360 C - 4
360 C - 4
CR CR
CR
CR
CR
CR
CR
2 DPS_EL
DPS_EL_RXDPS_EL_RX
DPS_EL_RX
DPS_EL_RX
DC
DPS_EL_RX
STAIR
132
STAIR
113
OPEN OFFICE
121
CADD ROOM
140
OPEN OFFICE
101
ENGINEER IV
118
ELEVATOR
161
WOMEN
129
OPEN OFFICE
157
ENGINEER V
105
CONFERENCE ROOM
137
STAFF TOILET
135
Room
000
CORRIDOR
160
CONFERENCE ROOM
114
OPEN OFFICE
106
SHARED WORK AREA
112
STAIR
149
OPEN OFFICE
143
BREAKROOM
138CONFERENCE ROOM
139
OPEN OFFICE
153
STAFF TOILET
133
MEN
130
LACTATION
127
HOUSEKEEPING
128
PLUMBING ACCESS
259
PLUMBING ACCESS
134
PHONE BOOTH
136
SYSTEMS ANALYST III
144
SYSTEMS ANALYST III
145
GIS COORDINATOR
146
CADD SUPERVISOR
142
ENGINEERING TECHNICIAN III
141
1:1 CONFERENCE
147
STORAGE
131
QA/QC MANAGER
107
1:1 CONFERENCE
111
ENGINEER V
152
STORAGE
151
ENGINEER IV
155
ENGINEER IV
156
ENGINEER V
154
PROJECT MANAGER SUPERVISOR
124
PROJECT MANAGER SUPERVISOR
125
TECHNICAL SERVICES MANAGER
126
STORMWATER ENGINEERINGCENTER ADMINISTRATOR
120
ENGINEER V
119
ENGINEER IV
117
ENGINEER IV
116
OPEN OFFICE
110
1:1 CONFERENCE
122
ENGINEER IV
108
HUDDLE AREA
115
OPEN OFFICE
104
ADMINISTRATIVE SPECIALIST I
103
STORAGE
102
LOBBY
100 ENGINEER IV
158
ENGINEER IV
159
ELECTRICAL
109
IT ROOM
123
HUDDLE AREA
148ELECTRICAL
150
DPS_EL_RX
DPS_EL_RX
DPS_EL_RX
DPS_EL_RX
DPS_EL_RX
DPS_EL_RX
NOTE: SECURITY DEVICES AND WIRING SHALL BE PROVIDED BY OTHERS AND ARE SHOWN FOR COORDINATION ONLY. DESIGN BUILD TEAM SHALL CONTINUE TO SHOW FOR COORDINATION. CONDUIT, BOXES, PULL STRINGS, AND OTHER REQUIRED ROUGH-IN SHALL BE PROVIDED BY THE DESIGN BUILD CONTRACTOR.
NOTE: DEMOUNTABLE PARTITIONS AND DOORS SHOWN DASHED FOR INFORMATION AND COORDINATION PURPOSES ONLY, NIC. REFER TO THE FURNITURE DRAWINGS AND THE PROJECT MANUAL PREAMBLE-ALTERNATES AND UNIT PRICING FOR ADDITIONAL INFORMATION
MO
SE
LE
YA
RC
HIT
EC
TS
.CO
M
PROJECT NO:DATE:
320
0 N
OR
FO
LK
ST
RE
ET
, R
ICH
MO
ND
, V
A 2
323
0
PH
ON
E (
80
4)
79
4-7
555
F
AX
(8
04
) 3
55
-569
0
A
B
C
D
E
1 2 4 53 6 7 8 9 10
F
G
H
I
J
3/3
1/2
02
0 4
:46:2
9 P
M
SECURITY OVERALL
PLAN FIRST FLOOR
CIT
Y O
F V
IRG
INIA
BE
AC
H
BU
ILD
ING
11
RE
NO
VA
TIO
N
Pro
ject
Ad
dre
ss
TY1.2.0
PW
CN
-18-
0156
CIP
-3-1
74
548507MARCH 31, 2020
1/8" = 1'-0"1
SECURITY OVERALL PLAN FIRST FLOOR
REVISIONS
DATE DESCRIPTION
CR
CR
C - 1
C -
1C
-1
360 C - 4
CR
CR
CR
CR
OPEN OFFICE
205
OPEN OFFICE
220
OPEN OFFICE
213
OPEN OFFICE
209
SHARED WORK AREA
234
CORRIDOR
201
STAIR
254
ELEVATOR
235
STAIR
211
MEN
202
MECH
219
?
?
CONFERENCE ROOM
208
CITY ENGINEER
223
CONFERENCE ROOM
231
CONFERENCE ROOM
221
CONFERENCE ROOM
225
WOMEN
203
ACCESS
204
LACTATION ROOM
206
DPS_EL_RX
DPS_EL_RX
ENGINEER V
207
CONTRACT SUPERVISOR
210
ENGINEER IV
214
ENGINEER V
215
ADMIN ASST
217
FILES
216
1:1 CONFERENCE
222
ADMINISTRATIVE SERVICESMANAGER III
224
OPERATIONS SUPPORTADMINISTRATOR
226
DIRECTOR
227
EXECUTIVE ASSISTANT
228
MEDIA & COMMUNICATIONS
229
IT POSITION
230
FILE ROOM
212
ELECTRICAL
218
IT ROOM
232
STORAGE
233
DPS_EL_RX
DPS_EL_RX
DPS_EL_RX
DPS_EL_RX
NOTE: SECURITY DEVICES AND WIRING SHALL BE PROVIDED BY OTHERS AND ARE SHOWN FOR COORDINATION ONLY. DESIGN BUILD TEAM SHALL CONTINUE TO SHOW FOR COORDINATION. CONDUIT, BOXES, PULL STRINGS, AND OTHER REQUIRED ROUGH-IN SHALL BE PROVIDED BY THE DESIGN BUILD CONTRACTOR.
NOTE: DEMOUNTABLE PARTITIONS AND DOORS SHOWN DASHED FOR INFORMATION AND COORDINATION PURPOSES ONLY, NIC. REFER TO THE FURNITURE DRAWINGS AND THE PROJECT MANUAL PREAMBLE-ALTERNATES AND UNIT PRICING FOR ADDITIONAL INFORMATION
MO
SE
LE
YA
RC
HIT
EC
TS
.CO
M
PROJECT NO:DATE:
320
0 N
OR
FO
LK
ST
RE
ET
, R
ICH
MO
ND
, V
A 2
323
0
PH
ON
E (
80
4)
79
4-7
555
F
AX
(8
04
) 3
55
-569
0
A
B
C
D
E
1 2 4 53 6 7 8 9 10
F
G
H
I
J
3/3
1/2
02
0 4
:46:3
0 P
M
SECURITY OVERALL
PLAN SECOND FLOOR
CIT
Y O
F V
IRG
INIA
BE
AC
H
BU
ILD
ING
11
RE
NO
VA
TIO
N
Pro
ject
Ad
dre
ss
TY1.3.0
PW
CN
-18-
0156
CIP
-3-1
74
548507MARCH 31, 2020
1/8" = 1'-0"1
SECURITY OVERALL PLAN SECOND FLOOR
REVISIONS
DATE DESCRIPTION
C-1 VIDEO SURVEILLANCE - FIXED IP DOME - CEILING OR WALL MOUNTED - FLUSH MOUNTED - INTERIOR
1
6 37
2
4
5
5
7
3
4
2
1
6
C-17 VIDEO SURVEILLANCE - FIXED IP DOME - WALLPENDANT MOUNTED - EXTERIOR
7
3
6
3
10
9
8
C-2
8'-0" MIN.15'-0" MAX.
FINISHED GRADE
FINISHED CEILING
8'-0" MIN.15'-0" MAX.
FINISHED GRADE
FINISHED CEILING
FIELD CONDITION "A" FIELD CONDITION "B"
VIDEO SURVEILLANCE - FIXED IP DOME - WALL SURFACE MOUNTED - EXTERIOR
5
1
11
12
7
6
5
1
11
12
7
6
C-3VIDEO SURVEILLANCE - 360 DEGREE HEMISPHERIC DOME - CEILING FLUSH MOUNTED - INTERIOR
1
6 37
2
4
5
C-4VIDEO SURVEILLANCE - MULTI-SENSOR DOME - CEILING FLUSH MOUNTED - INTERIOR
1
6 37
2
4
5
CAMERA DETAIL NOTES
1 CAMERA BACK BOX
2 TOGGLE BOLTS (AS REQUIRED)
3 IP DATA JACK PROVIDED. 6"x6"x4" JUNCTION BOX.
4 CEILING SOFFIT
5 CAMERA
6 IP JUMPER CABLE.
7 3/4" CONDUIT TO NEAREST ACCESSIBLE CEILING OR CABLE TRAY.
8 PENETRATION IN WALL FILLED WITH APPROVED SEALANT
CCTV fIXED CAMERA IN ENVIRONMENTAL HOUSING MOUNTED
EXTERIOR WALL
9
10
NOTE: SECURITY DEVICES AND WIRING SHALL BE PROVIDED BY OTHERS AND ARE SHOWN FOR COORDINATION ONLY. DESIGN BUILD TEAM SHALL CONTINUE TO SHOW FOR COORDINATION. CONDUIT, BOXES, PULL STRINGS, AND OTHER REQUIRED ROUGH-IN SHALL BE PROVIDED BY THE DESIGN BUILD CONTRACTOR.
MO
SE
LE
YA
RC
HIT
EC
TS
.CO
M
PROJECT NO:DATE:
320
0 N
OR
FO
LK
ST
RE
ET
, R
ICH
MO
ND
, V
A 2
323
0
PH
ON
E (
80
4)
79
4-7
555
F
AX
(8
04
) 3
55
-569
0
A
B
C
D
E
1 2 4 53 6 7 8 9 10
F
G
H
I
J
3/3
1/2
02
0 4
:46:3
1 P
M
SECURITY DETAILS
CIT
Y O
F V
IRG
INIA
BE
AC
H
BU
ILD
ING
11
RE
NO
VA
TIO
N
Pro
ject
Ad
dre
ss
TY5.0.1
PW
CN
-18-
0156
CIP
-3-1
74
548507MARCH 31, 2020
REVISIONS
DATE DESCRIPTION
REF.
FEC
D D
D
D
D
DD
D
3D
DD
D D
OD
OD
3D
3D
3D
OS
OD
OD
D
D
OD
3D
OD
3D
4D
DD
D
OD
DOD
D
3D
3D
OSOS OS
OD
OD
3
3
A
A
B
B
D
D
E
E
F
F
G
G
H
H
J
J
K
K
M
M
Q
Q
R
R
S
S
V
V
C
C
L
L
N
N
O
O
P
P
1 1
2 2
3 3
4 4
5 5
6 6
7 7
8 8
9 9
10
10
11 11
12 12
13 13
14 14
15 15
17 17
16 16
18 18
19 19
T
T
U
U
5.1 5.1
PRINT SHOP
007
STAFF TOILET
020
CIRCULATION
002
STAIR
006OPEN OFFICE
003
OPEN OFFICE
024
OPEN OFFICE
030CONFERENCE
ROOM
047
MECHANICAL
ROOM
044
STAIR
001
BOOT WASH
043
CONFERENCE
ROOM
048
WORKROOM
023
1:1
CONFERENCE
029
STAFF TOILET
021
ELECTRICAL
046
HOUSEKEEPING
041
LACTATION
042
ASSET
RECOVERY
005
ELEVATOR
049
ELEV EQUIP
022
TIER 1 CALL
CENTER
011
NOC
015
ITAC
016
INFO SEC
017
CA
SUPERVISOR
013
CONVERGENT
ARCHITECTURE
LAB
014
CTO
SUPERVISOR
004
PRINT ROOM -
STAFF
008
ASSET
RECOVERY -
STAFF
009
SOLUTIONS
ENGINEER
SUPERVISOR
010
OPS MANAGER
012
INFO SEC MGR
018
DIVISION
MANAGER
025
INSPECTION
COORDINATOR
II
026
CONSTRUCTION
BUREAU
MANAGER
027
STORAGE
028
SURVEY
TECHNICIAN
031
STORAGE
035
CREW ROOM
036
STORAGE
037
A
A A
A A
A
AA
D1
D1D1
D1
B
A
A
A
E1 E1 E1
E1E1
E1
AA
AA
AAA
A A
A A A A
AAA
A A A
A A A A A
A
A
A
A
A
A
A A A A
AAAA
A
A
A
A
A
A
A
A
A
A
A
A A
A
A
A
A A
A
A
A
A A
A
A
A
A A
A
A
A
A A
A
A
A
A A
A
A
A
A
A
A
AAAA
A
AA
AA
A A
A A
A B
A A
B
B
BB
B
B
B
A
A A
A A
A
B B B
A
A A
A A
A
A
A
A
A
A
A
A A A
AAA
A A A A A
AAAAA
A A A A A
AAAAA
A A A A A
AAAAA
A A A
A A A
AAA
E1 E1
E1
E1
E1 E1
E1
E1
E1 E1
E1E1
A
A A
A A
A
A A
A A
A
A
A
A
A A
A
A
A
A A
A
A
A
A A
A
A
A
A A
A
A
A
A A
A
A
A
A
E2
E2
E1
E1 E1 E1
E1
E1
E2 E2
E2E2
S1
S1
E1
E1
E1
E1
E1
E1
E1
E1
E1
E1
E1
E1
E1
E1
E1
E1
E1
E1
+9'-0"AFF
+9'-0"AFF
+9'-0"AFF +9'-0"AFF
+9'-0"AFF+9'-0"AFF
MOUNT LIGHT
FIXTURES IN
ELEVATOR PIT.
X1
X1X2
X2
X2
X1
MOSELEYARCHITECTS.COM
PROJECT NO:
DATE:
3200 N
OR
FO
LK
ST
RE
ET
, R
ICH
MO
ND
, V
A 2
3230
PH
ON
E (
804)
794-7
555 F
AX
(804)
355-5
690
A
B
C
D
E
1 2 4 53 6 7 8 9 10
F
G
H
I
J
4/1
3/2
02
0 5
:51
:42
PM
BASEMENT
LIGHTING PLAN
CIT
Y O
F V
IRG
INIA
BE
AC
H
BU
ILD
ING
11
-P
UB
LIC
WO
RK
S
VIR
GIN
IA B
EA
CH
, V
IRG
INIA
234
56
E2.1.1
PW
CN
-20
-00
84
CIP
-3-1
74
PROGRESS
PRINT NOT FOR
CONSTRUCTION
584507
MARCH 31, 2020
1/8" = 1'-0"
BASEMENT LIGHTING PLAN
REVISIONS
DATE DESCRIPTION
04-13-20 *AD 01
FOOTCANDLES
THE CONTRACTOR SHALL BE RESPONSIBLE FOR
FOOTCANDLE CALCULATIONS AND SELECTING THE
CORRECT LUMEN PACKAGE FOR THE LIGHT FIXTURES TO
MEET THE DESIRED LIGHTING LEVELS.
*AD 01
DRAWING LIST SYMBOLS: SYMBOLS:
ABBREVIATIONS:
AFF - ABOVE FINISHED FLOORAV - AUDIOVISUALC - CONDUITCAT-3 - TIA/EIA CATEGORY 3 RATEDCAT-5E - TIA/EIA CATEGORY 5e RATEDCAT-6 - TIA/EIA CATEGORY 6 RATEDCLG - CEILINGCOAX - COAXIAL CABLECP - CONSOLIDATION POINTF.O. - FIBER OPTICGND - GROUNDIC - INTERMEDIATE CROSS-CONNECTI.D. - INSIDE DIAMETERIDF - INTERMEDIATE DISTRIBUTION FRAMEJB - JUNCTION BOXLAN - LOCAL AREA NETWORKMC - MAIN CROSS-CONNECTMDF - MAIN DISTRIBUTION FRAMEMH - MANHOLEMM - MULTIMODEMTER - MAIN TELECOMMUNICATIONS EQUIPMENT ROOMNIC - NOT IN CONTRACTNTS - NOT TO SCALEO.D. - OUTSIDE DIAMETEROFE - OWNER FURNISHED EQUIPMENTOSP - OUTSIDE PLANTP.P. - PATCH PANELPR - PAIRPB - PULLBOXPBX - PRIVATE BRANCH EXCHANGERW - RACEWAYSM - SINGLE MODEST - STRANDSTP - SHIELDED TWISTED PAIRTEMP - TEMPORARYTGB - TELECOMMUNICATIONS GROUND BARTR - TELECOMMUNICATIONS ROOMTSER - TELECOMMUNICATIONS SERVICE ENTRANCE ROOMTYP - TYPICALU.O.N. - UNLESS OTHERWISE NOTEDUPS - UNINTERRUPTIBLE POWER SUPPLYUTP - UNSHIELDED TWISTED PAIRVOIP - VOICE OVER INTERNET PROTOCOLWAN - WIDE AREA NETWORKWAO - WORK AREA OUTLETWAP - WIRELESS ACCESS POINTW.M.O. - WIRE MANAGEMENTWP - WEATHERPROOFWS - WORKSTATIONWW - WIREWAY
PATH FOR ROUTING OF TELECOMMUNICATIONS CABLING IN THE CEILING
PATH FOR ROUTING OF TELECOMMUNICATIONS CABLING IN THE CEILING OF THE FLOOR BELOW
CONDUITS/CONDUIT SLEEVES - UP/DOWN
DRAWING NUMBER/DETAIL CALLOUT
GENERAL NOTES:
1. REFER TO DIVISION-26 SPECIFICATION FOR INSTALLATION (BY OTHERS) OF FLOOR BOXES, WALL BOXES, PULL BOXES, CONDUITS, RACEWAYS, MANHOLES, ETC.
2. REFER TO DIVISION-27 SPECIFICATIONS FOR INSTALLATION UNDER THIS SECTION OF TELECOM INFRASTRUCTURE ELEMENTS INCLUDING RACK, CABINETS, CABLE TRAY, BACKBOARDS, GROUNDING, BONDING AND STRUCTURE CABLING SYSTEMS (SCS).
3. INSTALL FIRESTOP TO ALL SLAB AND WALL PENETRATIONS PROVIDED FOR THE INSTALLATION OF TELECOMMUNICATIONS CABLE AS REQUIRED TO MAINTAIN FIRE RATING OF SLAB OR WALL. REVIEW ARCHITECT'S PLANS FOR PARTITION TYPES.
4. PROVIDE SMOKE/FIRE/ACOUSTIC PROOF POKE THROUGH DEVICE (EZ-PATH) AT ALL CABLE PENETRATIONS, THROUGH RATED FLOORS AND WALLS.
CABLING NOTES:
1. PROVIDE IDENTIFICATION LABELS FOR ALL TELECOMMUNICATIONS CABLES AT BOTH ENDS.
2. PROVIDE DESIGNATION LABELS FOR ALL TERMINATION BLOCKS, PATCH PANELS, AND WORKSTATION OUTLET FACEPLATES.
3. COORDINATE WALL BOX LOCATIONS AND DIMENSIONS WITH ARCHITECTURAL AND ELECTRICAL PLANS.
4. COORDINATE WITH ELECTRICAL DRAWINGS FOR LOCATION OF ALL TELECOMMUNICATIONS OUTLETS (WAO's). WAO'S MAY BE STUBBED INTO NEAREST ACCESSIBLE CEILING SPACE WITH J-HOOKS PROVIDED BETWEEN WAO CONDUIT STUB AND ABOVE CEILING CABLE TRAY.
5. INSTALL CONDUIT AND LADDER CABLE TRAY FOR TELECOMMUNICATIONS CABLING TO MAINTAIN A MINIMUM OF 5" SEPARATION FROM FLUORESCENT LIGHTING.
6. PROVIDE CABLE J-HOOKS NO GREATER THAN 5' APART TO SUPPORT CABLES WHERE NO CABLE TRAYS AND CONDUITS ARE PROVIDED.
7. INSTALL EACH CABLE SET INDICATED BY THE SYMBOLS LIST FROM THE OUTLET LOCATION BACK TO THE RESPECTIVE SERVING TELECOM ROOM.
8. IF CONFLICTS ARE FOUND BETWEEN THE TELECOMMUNICATIONS DRAWINGS AND ANY OTHER DRAWINGS ASSOCIATED WITH THE PROJECT, NOTIFY THE ARCHITECT AT ONCE AND HAVE LOCATION VERIFIED BEFORE OUTLETS ARE INSTALLED. ANY REASONABLE CHANGE IN LOCATION OF OUTLETS PRIOR TO ROUGHING SHALL NOT INVOLVE ADDITIONAL EXPENSE TO THE OWNER. THE TERM "REASONABLE" SHALL BE INTERPRETED AS MOVING OUTLET LOCATIONS A MAXIMUM OF 10' IN ANY DIRECTION FROM THE LOCATION INDICATED ON THE DRAWINGS.
9. CABLE ADMINISTRATION:
A. PROPERLY TAG ALL CABLES, RECEPTACLES, CONNECTION BLOCKS AND PATCH PANELS.
B. REPORT ANY CABLE THAT EXCEEDS 75m TO THE DESIGN TEAM, THE CABLE SHALL BE CLEARLY MARKED WITH RED TAPE AT BOTH ENDS OF EACH CABLE INDICATING THE EXACT CABLE LENGTH AND NOTED IN THE REQUIRED AS-BUILT LABEL REPORT.
C. PRIOR TO SYSTEM ACCEPTANCE, THE CONTRACTOR SHALL SUBMIT AN AS-BUILT LABEL REPORT PROVIDING THE ROOM NUMBERS AND CABLE LENGTHS FOR EACH OF THE INSTALLED CABLES.
10. LABEL REQUIREMENTS:
A. PROVIDE WHITE LABEL WITH TYPEWRITTEN LEGIBLE CHARACTERS. PRINTED WITH NON-SMEAR TYPE INK. HANDWRITTEN LABELS ARE NOT PERMITTED.
B. PROVIDE LABELS WITH A SELF ADHESIVE BACKING.
C. PROVIDE LABELS FOR CABLES WITH PROTECTIVE WRAP-AROUND PLASTIC TRANSPARENT COVER WHICH WILL SERVE TO PROTECT THE INK FROM SMEARING AND SECURE THE LABEL TO THE CABLE.
D. PROVIDE LABELS FOR CABLES WIDE ENOUGH FOR 23 CHARACTERS IN A SINGLE ROW.
E. RISER AND TIE CABLES JACKETS SHALL BE LABELED WITHIN EACH TECHNOLOGY ROOM AND AT 15m INTERVALS OUTSIDE TECHNOLOGY ROOMS ABOVE CEILINGS.
PATHWAY NOTES:
1. COORDINATE INSTALLATION OF CONDUITS, J-HOOKS AND CABLE TRAYS WITH OTHER COMPONENTS INSTALLED WITHIN CEILING. PREPARE SHOP DRAWINGS TO DEMONSTRATE AND ENSURE PROPER INSTALLATION OF ALL COMPONENTS.
2. MAINTAIN MINIMUM BEND RADIUS OF 10X O.D. FOR CONDUITS GREATER THAN 2" DIAMETER. MAINTAIN MINIMUM BEND RADIUS OF 6X O.D. FOR CONDUITS EQUAL TO OR LESS THAN 2" DIAMETER.
3. PROVIDE PULL BOXES (SIZE AS NOTED) AFTER EVERY 150 FEET OF RUN OR AFTER EVERY 180-DEGREES OF BEND.
4. DO NOT INSTALL PULL BOXES IN LIEU OF A BEND.
5. REAM AND BUSH THE ENDS OF ALL CONDUITS.
6. PROVIDE AND LEAVE IN PLACE A PULL 200 LB TEST LINE IN EACH CONDUIT.
7. STUB UP CONDUIT SLEEVES THROUGH SLABS 3" ABOVE FINISHED FLOORS.
8. PROVIDE HANGERS, ANCHORS, MOUNTING HARDWARE, GROUND LUGS AND STRAPS AS REQUIRED TO ENSURE PROPER INSTALLATION OF PATHWAY COMPONENTS. INSTALL ALL COMPONENTS AS PER MANUFACTURERS RECOMMENDATIONS AND PER ALL APPLICABLE CODES.
9. GROUND ALL CONDUITS AND CABLE TRAY AS PER MANUFACTURERS' RECOMMENDATIONS, INDUSTRY STANDARDS AND PER ALL APPLICABLE CODES.
10. PROVIDE AT ALL CABLE TRAY AND CABLE TRAY LOCATIONS: RUNWAY DROPOFFS, SPLICE HARDWARE, GROUND STRAPS, THERMAL EXPANSION PLATES, TERMINATION KITS, END SUPPORT KITS AND CEILING SUPPORT HARDWARE.
11. REFER TO DISTRIBUTION PLANS FOR REQUIREMENTS FOR JUNCTION BOX AND CONDUITS TO SUPPORT WORK AREA OUTLETS.
T-XXX
1
12.WHERE CABLE IS RUN ABOVE NON-ACCESSIBLE (I.E. GYPSUM BOARD) CEILING CONSTRUCTION, CONDUIT, PULLBOXES AND ACCESS PANELS SHALL BE INSTALLED TO PROPERLY ROUTE CABLE.
13.PROVIDE J-HOOKS AND CABLE STRAPS TO SUPPORT CABLE ABOVE ACCESSIBLE CEILING CONSTRUCTION, EXCEPT IN AREAS WHERE CABLE TRAY OR CONDUIT IS INDICATED.
PATHWAY NOTES:WALL MOUNTED SINGLE PORT WAO (1) CATEGORY 6 CABLE TO THE DESIGNATED TECHNOLOGY ROOM PROVIDE 4" BOX W/1-GANG OPENING AND 1-1/4" CONDUIT FROM THE WAO TO THE NEAREST CABLE TRAY OR TR."CP"= WALL MOUNTED AV CONTROL PANEL"E"= WALL MOUNTED WAO FOR ELEVATOR CONTROLLER
WALL MOUNTED DUAL PORT WAO (2) CATEGORY 6 CABLES TO THE DESIGNATED TECHNOLOGY ROOM PROVIDE 4" BOX W/1-GANG OPENING AND 1-1/4" CONDUIT FROM THE WAO TO THE NEAREST CABLE TRAY OR TR.
"E"= WALL MOUNTED WAO FOR ELEVATOR CONTROLLER"AP"= SECURITY ALARM PANEL
WALL MOUNTED 3-PORT WAO (3) CATEGORY 6 CABLES TO THE DESIGNATED TECHNOLOGY ROOM PROVIDE 4" BOX W/1-GANG OPENING AND 1-1/4" CONDUIT FROM THE WAO TO THE NEAREST CABLE TRAY OR TR.
WALL MOUNTED 4-PORT WAO (UON) - (4) CATEGORY 6 CABLES TO THE DESIGNATED TECHNOLOGY ROOM PROVIDE 4" BOX W/1-GANG OPENING AND 1-1/4" CONDUIT FROM THE WAO TO THE NEAREST CABLE TRAY OR TR. A NUMBER "6" ADJUST TO THIS SYMBOL INDICATES 6 CATEGORY 6 CABLES TO BE PROVIDED IN LIEU OF 4.
"ACP"= SECURITY ACCESS CONTROL PANEL
WALL MOUNTED CAMERA 1-PORT WAO (1) CATEGORY 6A CABLE TO THE DESIGNATED TECHNOLOGY ROOM PROVIDE 3/4" CONDUIT FROM THE WAO TO THE NEAREST CABLE TRAY OR TR
CAM
WALL MOUNTED CATV WAO (2) CATEGORY 6A SHIELDED CABLES TO THE DESIGNATED TECHNOLOGY ROOM PROVIDE 1-1/4" CONDUIT FROM THE WAO TO THE NEAREST CABLE TRAY OR TR. BACK BOX IS COMBINED WITH AV AND POWER (REFER TO AV AND ELEC. DWGS.)
TV
WALL MOUNTED WAP 2-PORT WAO (2) CATEGORY 6A CABLES TO THE DESIGNATED TECHNOLOGY ROOM PROVIDE 1-1/4" CONDUIT FROM THE WAO TO THE NEAREST CABLE TRAY OR TR.
WAP
WALL MOUNTED TELEPHONE (48" AFF) PROVIDE (1) CATEGORY 6 CABLE TO THE DESIGNATED TECHNOLOGY ROOM PROVIDE 1-1/4" CONDUIT FROM THE OUTLET TO THE NEAREST CABLE TRAY OR TR.
W
FLOOR MOUNTED SINGLE 1-PORT WAO (1) CATEGORY 6 CABLES TO THE DESIGNATED TECHNOLOGY ROOM PROVIDE SINGLE-GANG FLOOR BOX AND 1-1/4" CONDUIT FROM THE WAO TO THE NEAREST CABLE TRAY OR TR.
FLOOR MOUNTED 2-PORT WAO (2) CATEGORY 6 CABLES TO THE DESIGNATED TECHNOLOGY ROOM PROVIDE SINGLE-GANG FLOOR BOX AND 1-1/4" CONDUIT FROM THE WAO TO THE NEAREST CABLE TRAY OR TR.
FLOOR BOX MOUNTED 3-PORT WAO (3) CATEGORY 6 CABLES TO THE DESIGNATED TECHNOLOGY ROOM PROVIDE SINGLE-GANG FLOOR BOX AND 1-1/4" CONDUIT FROM THE WAO TO THE NEAREST CABLE TRAY OR TR.
FLOOR BOX MOUNTED 4-PORT WAO (UON) - (4) CATEGORY 6 CABLES TO THE DESIGNATED TECHNOLOGY ROOM PROVIDE SINGLE-GANG FLOOR BOX AND 1-1/4" CONDUIT FROM THE WAO TO THE NEAREST CABLE TRAY OR TR.
FLOOR POKE-THRU MOUNTED 1-PORT WAO (1) CATEGORY 6 CABLE TO THE DESIGNATED TECHNOLOGY ROOM PROVIDE POKE-THRU DEVICE AND 1-1/4" CONDUIT FROM THE WAO TO THE NEAREST CABLE TRAY OR TR.
FLOOR POKE-THRU MOUNTED 2-PORT WAO (2) CATEGORY 6 CABLES TO THE DESIGNATED TECHNOLOGY ROOM PROVIDE POKE-THRU DEVICE AND 1-1/4" CONDUIT FROM THE WAO TO THE NEAREST CABLE TRAY OR TR
FLOOR POKE-THRU MOUNTED 3-PORT WAO (3) CATEGORY 6 CABLES TO THE DESIGNATED TECHNOLOGY ROOM PROVIDE POKE-THRU DEVICE AND 1-1/4" CONDUIT FROM THE WAO TO THE NEAREST CABLE TRAY OR TR.
FLOOR POKE-THRU MOUNTED 4-PORT WAO (UON) - (4) CATEGORY 6 CABLES TO THE DESIGNATED TECHNOLOGY ROOM PROVIDE POKE-THRU DEVICE AND 1-1/4" CONDUIT FROM THE WAO TO THE NEAREST CABLE TRAY OR TR.
FURNITURE MOUNTED SINGLE PORT WAO (1) CATEGORY 6 CABLE TO THE DESIGNATED TECHNOLOGY ROOM PROVIDE 1-1/4" FLEXIBLE WHIP FROM THE WAO LOCATION TO THE FURNITURE IN-FEED.
FURNITURE MOUNTED DUAL PORT WAO (2) CATEGORY 6 CABLES TO THE DESIGNATED TECHNOLOGY ROOM PROVIDE 1-1/4" FLEXIBLE WHIP FROM THE WAO LOCATION TO THE FURNITURE IN-FEED.
FURNITURE MOUNTED 3-PORT WAO (3) CATEGORY 6 CABLES TO THE DESIGNATED TECHNOLOGY ROOM PROVIDE 1-1/4"" FLEXIBLE WHIP FROM THE WAO LOCATION TO THE FURNITURE IN-FEED.
FURNITURE MOUNTED 4-PORT WAO (4) CATEGORY 6 CABLES TO THE DESIGNATED TECHNOLOGY ROOM PROVIDE 1-1/4"" FLEXIBLE WHIP FROM THE WAO LOCATION TO THE FURNITURE IN-FEED.
WALL MOUNTED FURNITURE IN-FEED PROVIDE DOUBLE-GANG BACK BOX AND 2" CONDUIT FROM THE OUTLET TO THE NEAREST CABLE TRAY OR TR.
FLOOR MOUNTED FURNITURE IN-FEED PROVIDE DOUBLE-GANG FLOOR BOX AND 2" CONDUIT FROM THE OUTLET TO THE NEAREST CABLE TRAY OR TR.
FLOOR MOUNTED FURNITURE IN-FEED PROVIDE DOUBLE-GANG FLOOR BOX AND 2" CONDUIT FROM THE OUTLET TO THE NEAREST CABLE TRAY OR TR.
CEILING MOUNTED SINGLE PORT OUTLET (1) CATEGORY 6A CABLE TO THE DESIGNATED TECHNOLOGY ROOM PROVIDE SINGLE-GANG BACK BOX AND 3/4" CONDUIT FROM THE OUTLET TO THE NEAREST CABLE TRAY OR TR. PROVIDE 20 FEET OF CABLE SERVICE LOOP OF EACH CEILING OUTLET LOCATION.
"CAM"= CEILING MOUNTED SECURITY CAMERA WAO (PROVIDE 3/4" CONDUIT IN LIEU OF 1/4" CONDUIT FOR CAMERAS)
CEILING MOUNTED DUAL PORT OUTLET (2) CATEGORY 6A CABLES TO THE DESIGNATED TECHNOLOGY ROOM PROVIDE SINGLE-GANG BACK BOX AND 1-1/4"" CONDUIT FROM THE OUTLET TO THE NEAREST CABLE TRAY OR TR. PROVIDE 20 FEET OF CABLE SERVICE LOOP OF EACH CEILING OUTLET LOCATION.
"TV"= CEILING MOUNTED CATV WAO - INCLUDE ONE COAXIAL CABLE (PROVIDE SERIES 6 COAX UP TO 149 FEET AND SERIES 11 COAX FROM 150 FEET TO 295 FEET IN LENGTH)."WAP"= CEILING MOUNTED WAP WAO"VP"= CEILING MOUNTED VIDEO PROJECTOR WAO
WIRE BASKET TYPE CABLE TRAY SIZE AS INDICATED
LADDER TYPE CABLE TRAY SIZE AS INDICATED.
WALL MOUNTED ONE COAXIAL CABLE (PROVIDE SERIES 6 COAX UP TO 149 FEET AND SERIES 11 COAX FROM 150 FEET TO 295 FEET IN LENGTH). TO THE DESIGNATED TECHNOLOGY ROOM PROVIDE 1-1/4" CONDUIT FROM THE WAO TO THE NEAREST CABLE TRAY OR TR. BACK BOX IS COMBINED WITH AV AND POWER (REFER TO AV AND ELEC. DWGS.)
CX
CABLE PATHWAY THROUGH MULLION - (1) CATEGORY 6A CABLE TO THE DESIGNATED TECHNOLOGY ROOM.
M
WALL MOUNTED EMERGENCY CALL STATION 1-PORT WAO (1) CATEGORY 6A CABLE TO THE DESIGNATED TECHNOLOGY ROOM PROVIDE 1-1/4" CONDUIT FROM THE WAO TO THE NEAREST CABLE TRAY OR TR
ECB
MO
SE
LE
YA
RC
HIT
EC
TS
.CO
M
PROJECT NO:DATE:
320
0 N
OR
FO
LK
ST
RE
ET
, R
ICH
MO
ND
, V
A 2
323
0
PH
ON
E (
80
4)
79
4-7
555
F
AX
(8
04
) 3
55
-569
0
A
B
C
D
E
1 2 4 53 6 7 8 9 10
F
G
H
I
J
3/3
1/2
02
0 4
:07:1
9 P
M
TELECOM LEGEND
CIT
Y O
F V
IRG
INIA
BE
AC
H
BU
ILD
ING
11
RE
NO
VA
TIO
N
Pro
ject
Ad
dre
ss
TT0.0.0
PW
CN
-18-
0156
CIP
-3-1
74
548507MARCH 31, 2020
NUMBER NAME
TT0.0.0 TELECOM LEGEND
TT1.1.0 TELECOM OVERALL PLAN LOWER
TT1.2.0 TELECOM OVERALL PLAN FIRST FLOOR
TT1.3.0 TELECOM OVERALL PLAN SECOND FLOOR
TT2.1.0 TELECOM OVERALL RCP LOWER
TT2.2.0 TELECOM OVERALL RCP FIRST FLOOR
TT2.3.0 TELECOM OVERALL RCP SECOND FLOOR
TT3.0.1 TELECOM ENLARGED PLAN
TT5.0.1 TELECOM DETAILS
TT5.0.2 TELECOM DETAILS
TT5.0.3 TELECOM DETAILS
REVISIONS
DATE DESCRIPTION
REF.
FEC
CA
M
CAM
FP
A
A
B
B
D
D
E
E
F
F
G
G
H
H
J
J
K
K
M
M
Q
Q
R
R
S
S
V
V
C
C
L
L
N
N
O
O
P
P
1 1
2 2
3 3
4 4
5 5
6 6
7 7
8 8
9 9
10 10
11 11
12 12
13 13
14 14
15 15
17 17
16 16
18 18
19 19
T
T
U
U
5.1 5.1
TT3.0.1
2
CITY SURVEYOR
033
1:1 CONFERENCE
032
SURVEY TECHNICIAN
031
1:1 CONFERENCE
029
STORAGE
028
OPEN OFFICE
030
STORAGE
035
STORAGE
037
CREW ROOM
036
HOUSEKEEPING
041 LACTATION
042
BOOT WASH
043
PHONE BOOTH
040PHONE BOOTH
039
PHONE BOOTH
038
MECHANICAL ROOM
044
IT SERVER
045
ELECTRICAL
046
CONFERENCE ROOM
047
CONFERENCE ROOM
048
STAFF TOILET
021
STAFF TOILET
020
ELEV EQUIP
022
BREAK ROOM
019
STAIR
001
SYSTEMS ENGINEER I
004
Room
051
Room
50
Room
51
OPEN OFFICE
003
WORKROOM
023
OPEN OFFICE
024
CONSTRUCTION BUREAU MANAGER
027
INSPECTION COORDINATOR II
026
DIVISION MANAGER
025
INFO SEC
017
INFO SEC MGR
018
ITAC
016NOC
015
CONVERGENT ARCHITECTURE LAB
014
CA SUPERVISOR
013
TIER 1 CALL CENTER
011
OPS MANAGER
012
SOLUTIONS ENGINEERSUPERVISOR
010ASSET RECOVERY - STAFF
009
PRINT ROOM - STAFF
008
PRINT SHOP
007
ASSET RECOVERY
005
STAIR
006
NOTE: DEMOUNTABLE PARTITIONS AND DOORS SHOWN DASHED FOR INFORMATION AND COORDINATION PURPOSES ONLY, NIC. REFER TO THE FURNITURE DRAWINGS AND THE PROJECT MANUAL PREAMBLE-ALTERNATES AND UNIT PRICING FOR ADDITIONAL INFORMATION
MO
SE
LE
YA
RC
HIT
EC
TS
.CO
M
PROJECT NO:DATE:
320
0 N
OR
FO
LK
ST
RE
ET
, R
ICH
MO
ND
, V
A 2
323
0
PH
ON
E (
80
4)
79
4-7
555
F
AX
(8
04
) 3
55
-569
0
A
B
C
D
E
1 2 4 53 6 7 8 9 10
F
G
H
I
J
3/3
1/2
02
0 4
:07:2
1 P
M
TELECOM OVERALL
PLAN LOWER
CIT
Y O
F V
IRG
INIA
BE
AC
H
BU
ILD
ING
11
RE
NO
VA
TIO
N
Pro
ject
Ad
dre
ss
TT1.1.0
PW
CN
-18-
0156
CIP
-3-1
74
548507MARCH 31, 2020
1/8" = 1'-0"1
TELECOM OVERALL PLAN LOWER
REVISIONS
DATE DESCRIPTION
REF.REF.
DN
DN
W
A
A
B
B
D
D
E
E
F
F
G
G
H
H
J
J
K
K
M
M
Q
Q
R
R
S
S
V
V
C
C
L
L
N
N
O
O
P
P
1 1
2 2
3 3
4 4
5 5
6 6
7 7
8 8
9 9
10 10
11 11
12 12
13 13
14 14
15 15
17 17
16 16
18 18
19 19
T
T
U
U
5.1 5.1
STAIR
132
STAIR
113
OPEN OFFICE
121
CADD ROOM
140
OPEN OFFICE
101
ENGINEER IV
118
ELEVATOR
161
WOMEN
129
OPEN OFFICE
157
ENGINEER V
105
CONFERENCE ROOM
137
STAFF TOILET
135
Room
000
CORRIDOR
160
CONFERENCE ROOM
114
OPEN OFFICE
106
SHARED WORK AREA
112
STAIR
149
OPEN OFFICE
143
BREAKROOM
138CONFERENCE ROOM
139
OPEN OFFICE
153
STAFF TOILET
133
MEN
130
LACTATION
127HOUSEKEEPING
128
PLUMBING ACCESS
259
PLUMBING ACCESS
134
PHONE BOOTH
136
SYSTEMS ANALYST III
144
SYSTEMS ANALYST III
145
GIS COORDINATOR
146
CADD SUPERVISOR
142
ENGINEERING TECHNICIAN III
141
1:1 CONFERENCE
147
STORAGE
131
QA/QC MANAGER
107
1:1 CONFERENCE
111
ENGINEER V
152
STORAGE
151
ENGINEER IV
155
ENGINEER IV
156
ENGINEER V
154
PROJECT MANAGER SUPERVISOR
124
PROJECT MANAGER SUPERVISOR
125
TECHNICAL SERVICES MANAGER
126
STORMWATER ENGINEERINGCENTER ADMINISTRATOR
120
ENGINEER V
119
ENGINEER IV
117
ENGINEER IV
116
OPEN OFFICE
110
1:1 CONFERENCE
122
ENGINEER IV
108
HUDDLE AREA
115
OPEN OFFICE
104
ADMINISTRATIVE SPECIALIST I
103
STORAGE
102
LOBBY
100 ENGINEER IV
158
ENGINEER IV
159
ELECTRICAL
109
IT ROOM
123
HUDDLE AREA
148ELECTRICAL
150
TT3.0.1
3
NOTE: DEMOUNTABLE PARTITIONS AND DOORS SHOWN DASHED FOR INFORMATION AND COORDINATION PURPOSES ONLY, NIC. REFER TO THE FURNITURE DRAWINGS AND THE PROJECT MANUAL PREAMBLE-ALTERNATES AND UNIT PRICING FOR ADDITIONAL INFORMATION
MO
SE
LE
YA
RC
HIT
EC
TS
.CO
M
PROJECT NO:DATE:
320
0 N
OR
FO
LK
ST
RE
ET
, R
ICH
MO
ND
, V
A 2
323
0
PH
ON
E (
80
4)
79
4-7
555
F
AX
(8
04
) 3
55
-569
0
A
B
C
D
E
1 2 4 53 6 7 8 9 10
F
G
H
I
J
3/3
1/2
02
0 4
:07:2
3 P
M
TELECOM OVERALL
PLAN FIRST FLOOR
CIT
Y O
F V
IRG
INIA
BE
AC
H
BU
ILD
ING
11
RE
NO
VA
TIO
N
Pro
ject
Ad
dre
ss
TT1.2.0
PW
CN
-18-
0156
CIP
-3-1
74
548507MARCH 31, 2020
1/8" = 1'-0"1
TELECOM OVERALL PLAN FIRST FLOOR
REVISIONS
DATE DESCRIPTION
A
A
B
B
D
D
E
E
F
F
G
G
H
H
J
J
K
K
M
M
Q
Q
R
R
S
S
V
V
C
C
L
L
N
N
O
O
P
P
1 1
2 2
3 3
4 4
5 5
6 6
7 7
8 8
9 9
10 10
11 11
12 12
13 13
14 14
15 15
17 17
16 16
18 18
19 19
T
T
U
U
5.1 5.1
OPEN OFFICE
205
OPEN OFFICE
220
OPEN OFFICE
213
OPEN OFFICE
209
SHARED WORK AREA
234
CORRIDOR
201
STAIR
254
ELEVATOR
235
STAIR
211
MEN
202
MECH
219
CONFERENCE ROOM
208
CITY ENGINEER
223
CONFERENCE ROOM
231
CONFERENCE ROOM
221
CONFERENCE ROOM
225
WOMEN
203
ACCESS
204
LACTATION ROOM
206
ENGINEER V
207
CONTRACT SUPERVISOR
210
ENGINEER IV
214
ENGINEER V
215
ADMIN ASST
217
FILES
216
1:1 CONFERENCE
222
ADMINISTRATIVE SERVICESMANAGER III
224
OPERATIONS SUPPORTADMINISTRATOR
226
DIRECTOR
227
EXECUTIVE ASSISTANT
228
MEDIA & COMMUNICATIONS
229
IT POSITION
230
FILE ROOM
212
ELECTRICAL
218
IT ROOM
232
STORAGE
233
TT3.0.1
5
NOTE: DEMOUNTABLE PARTITIONS AND DOORS SHOWN DASHED FOR INFORMATION AND COORDINATION PURPOSES ONLY, NIC. REFER TO THE FURNITURE DRAWINGS AND THE PROJECT MANUAL PREAMBLE-ALTERNATES AND UNIT PRICING FOR ADDITIONAL INFORMATION
MO
SE
LE
YA
RC
HIT
EC
TS
.CO
M
PROJECT NO:DATE:
320
0 N
OR
FO
LK
ST
RE
ET
, R
ICH
MO
ND
, V
A 2
323
0
PH
ON
E (
80
4)
79
4-7
555
F
AX
(8
04
) 3
55
-569
0
A
B
C
D
E
1 2 4 53 6 7 8 9 10
F
G
H
I
J
3/3
1/2
02
0 4
:07:2
4 P
M
TELECOM OVERALL
PLAN SECOND FLOOR
CIT
Y O
F V
IRG
INIA
BE
AC
H
BU
ILD
ING
11
RE
NO
VA
TIO
N
Pro
ject
Ad
dre
ss
TT1.3.0
PW
CN
-18-
0156
CIP
-3-1
74
548507MARCH 31, 2020
1/8" = 1'-0"1
TELECOM OVERALL PLAN SECOND FLOOR
REVISIONS
DATE DESCRIPTION
CAM
CAM
CAM
WAP WAP
WAP
WAP
WAP
WAP
WAP
CAM
A
A
B
B
D
D
E
E
F
F
G
G
H
H
J
J
K
K
M
M
Q
Q
R
R
S
S
V
V
C
C
L
L
N
N
O
O
P
P
1 1
2 2
3 3
4 4
5 5
6 6
7 7
8 8
9 9
10 10
11 11
12 12
13 13
14 14
15 15
17 17
16 16
18 18
19 19
T
T
U
U
5.1 5.1
3
3
TT3.0.1
1
IT SERVER
045
ELECTRICAL
046
MECHANICAL ROOM
044
HOUSEKEEPING
041
BOOT WASH
043
CREW ROOM
036
STORAGE
035
STORAGE
037
OPEN OFFICE
030
CITY SURVEYOR
033
1:1 CONFERENCE
032
SURVEY TECHNICIAN
031
1:1 CONFERENCE
029
STORAGE
028
CONSTRUCTION BUREAU MANAGER
027 INSPECTION COORDINATOR II
026 DIVISION MANAGER
025
OPEN OFFICE
024
WORKROOM
023
STAFF TOILET
021
STAFF TOILET
020
ELEV EQUIP
022
ELEVATOR
049
BREAK ROOM
019
CONFERENCE ROOM
047
CONFERENCE ROOM
048
Room
051
Room
50
STAIR
001
SYSTEMS ENGINEER I
004
OPEN OFFICE
003
CA SUPERVISOR
013
CONVERGENT ARCHITECTURE LAB
014
NOC
015
OPS MANAGER
012
ITAC
016
INFO SEC
017
INFO SEC MGR
018
OPEN OFFICE
003
SOLUTIONS ENGINEERSUPERVISOR
010
ASSET RECOVERY - STAFF
009 PRINT ROOM - STAFF
008
TIER 1 CALL CENTER
011
PRINT SHOP
007
STAIR
006
ASSET RECOVERY
005
NOTE: DEMOUNTABLE PARTITIONS AND DOORS SHOWN DASHED FOR INFORMATION AND COORDINATION PURPOSES ONLY, NIC. REFER TO THE FURNITURE DRAWINGS AND THE PROJECT MANUAL PREAMBLE-ALTERNATES AND UNIT PRICING FOR ADDITIONAL INFORMATION
MO
SE
LE
YA
RC
HIT
EC
TS
.CO
M
PROJECT NO:DATE:
320
0 N
OR
FO
LK
ST
RE
ET
, R
ICH
MO
ND
, V
A 2
323
0
PH
ON
E (
80
4)
79
4-7
555
F
AX
(8
04
) 3
55
-569
0
A
B
C
D
E
1 2 4 53 6 7 8 9 10
F
G
H
I
J
3/3
1/2
02
0 4
:07:2
7 P
M
TELECOM OVERALL
RCP LOWER
CIT
Y O
F V
IRG
INIA
BE
AC
H
BU
ILD
ING
11
RE
NO
VA
TIO
N
Pro
ject
Ad
dre
ss
TT2.1.0
PW
CN
-18-
0156
CIP
-3-1
74
548507MARCH 31, 2020
1/8" = 1'-0"1
TELECOM OVERALL RCP LOWER
TELECOM KEYNOTE LEGEND
NUMBER DESCRIPTION
3 12" X 4" BASKET TYPE CABLE TRAY ABOVE ACCESSIBLECEILING
REVISIONS
DATE DESCRIPTION
CAM
CAM
CA
M
CAM
CA
M
CA
M
CAM
CAM
CA
M
WAP
WAP
WAP
WAP
WAP
WAP
WAP
WAP
WAP WAP
WAP WAP
WAP
WAP
A
A
B
B
D
D
E
E
F
F
G
G
H
H
J
J
K
K
M
M
Q
Q
R
R
S
S
V
V
C
C
L
L
N
N
O
O
P
P
1 1
2 2
3 3
4 4
5 5
6 6
7 7
8 8
9 9
10 10
11 11
12 12
13 13
14 14
15 15
17 17
16 16
18 18
19 19
T
T
U
U
5.1 5.1
STAIR
132
STAIR
113
ELEVATOR
161
WOMEN
129
CONFERENCE ROOM
137
STAFF TOILET
135
Room
000
CORRIDOR
160
CONFERENCE ROOM
114
STAIR
149
CONFERENCE ROOM
139
STAFF TOILET
133
MEN
130
LACTATION
127
HOUSEKEEPING
128
PLUMBING ACCESS
259
PLUMBING ACCESS
134
PHONE BOOTH
136
3
3
IT ROOM
123
STORMWATER ENGINEERINGCENTER ADMINISTRATOR
120
ENGINEER V
119
ENGINEER IV
118
ENGINEER IV
117
ENGINEER IV
116
HUDDLE AREA
115
TECHNICAL SERVICES MANAGER
126
PROJECT MANAGER SUPERVISOR
125
PROJECT MANAGER SUPERVISOR
124
STORAGE
131
OPEN OFFICE
121
1:1 CONFERENCE
122
CADD ROOM
140
BREAKROOM
138
ENGINEER V
154
ENGINEER IV
156
ENGINEER IV
155
LOBBY
100
OPEN OFFICE
110
HUDDLE AREA
115
ENGINEER IV
116
TT3.0.1
4
NOTE: DEMOUNTABLE PARTITIONS AND DOORS SHOWN DASHED FOR INFORMATION AND COORDINATION PURPOSES ONLY, NIC. REFER TO THE FURNITURE DRAWINGS AND THE PROJECT MANUAL PREAMBLE-ALTERNATES AND UNIT PRICING FOR ADDITIONAL INFORMATION
MO
SE
LE
YA
RC
HIT
EC
TS
.CO
M
PROJECT NO:DATE:
320
0 N
OR
FO
LK
ST
RE
ET
, R
ICH
MO
ND
, V
A 2
323
0
PH
ON
E (
80
4)
79
4-7
555
F
AX
(8
04
) 3
55
-569
0
A
B
C
D
E
1 2 4 53 6 7 8 9 10
F
G
H
I
J
3/3
1/2
02
0 4
:07:2
9 P
M
TELECOM OVERALL
RCP FIRST FLOOR
CIT
Y O
F V
IRG
INIA
BE
AC
H
BU
ILD
ING
11
RE
NO
VA
TIO
N
Pro
ject
Ad
dre
ss
TT2.2.0
PW
CN
-18-
0156
CIP
-3-1
74
548507MARCH 31, 2020
1/8" = 1'-0"1
TELECOM OVERALL RCP FIRST FLOOR
TELECOM KEYNOTE LEGEND
NUMBER DESCRIPTION
3 12" X 4" BASKET TYPE CABLE TRAY ABOVE ACCESSIBLECEILING
REVISIONS
DATE DESCRIPTION
CAM
CAM
CAM
CAM
WAP WAP
WAP
WAP
WAP
WAP
WAP
A
A
B
B
D
D
E
E
F
F
G
G
H
H
J
J
K
K
M
M
Q
Q
R
R
S
S
V
V
C
C
L
L
N
N
O
O
P
P
1 1
2 2
3 3
4 4
5 5
6 6
7 7
8 8
9 9
10 10
11 11
12 12
13 13
14 14
15 15
17 17
16 16
18 18
19 19
T
T
U
U
5.1 5.1
OPEN OFFICE
205
OPEN OFFICE
209
SHARED WORK AREA
234
STAIR
254
ELEVATOR
235
STAIR
211
MEN
202
MECH
219
?
?
CONFERENCE ROOM
208
CONFERENCE ROOM
231
CONFERENCE ROOM
221
WOMEN
203
ACCESS
204
LACTATION ROOM
206
3
3
IT ROOM
232
TT3.0.1
6
NOTE: DEMOUNTABLE PARTITIONS AND DOORS SHOWN DASHED FOR INFORMATION AND COORDINATION PURPOSES ONLY, NIC. REFER TO THE FURNITURE DRAWINGS AND THE PROJECT MANUAL PREAMBLE-ALTERNATES AND UNIT PRICING FOR ADDITIONAL INFORMATION
MO
SE
LE
YA
RC
HIT
EC
TS
.CO
M
PROJECT NO:DATE:
320
0 N
OR
FO
LK
ST
RE
ET
, R
ICH
MO
ND
, V
A 2
323
0
PH
ON
E (
80
4)
79
4-7
555
F
AX
(8
04
) 3
55
-569
0
A
B
C
D
E
1 2 4 53 6 7 8 9 10
F
G
H
I
J
3/3
1/2
02
0 4
:07:3
1 P
M
TELECOM OVERALL
RCP SECOND FLOOR
CIT
Y O
F V
IRG
INIA
BE
AC
H
BU
ILD
ING
11
RE
NO
VA
TIO
N
Pro
ject
Ad
dre
ss
TT2.3.0
PW
CN
-18-
0156
CIP
-3-1
74
548507MARCH 31, 2020
1/8" = 1'-0"1
TELECOM OVERALL RCP SECOND FLOOR
TELECOM KEYNOTE LEGEND
NUMBER DESCRIPTION
3 12" X 4" BASKET TYPE CABLE TRAY ABOVE ACCESSIBLECEILING
REVISIONS
DATE DESCRIPTION
TGB
TGB
TG
BT
GB
TGB
TGB
IT SERVER
045
10
10
11
7
7
1
2
2
2
2
7' - 3 7/32" 1' - 3" 5' - 2 21/32"
18
' -
0"
IT SERVER
045
3
13
13
IT ROOM
123
10711710
4' -
5"
1' -
3"
4' -
4"
12' - 10 5/8"
1
2
2
2
2
IT ROOM
123
13
13
3
IT ROOM
232
2
1
10
7
11
7
10
2
2
2
4' - 5 27/32" 1' - 3" 4' - 3 5/32"
12
' -
7 1
/8"
IT ROOM
232
3
13
13
MO
SE
LE
YA
RC
HIT
EC
TS
.CO
M
PROJECT NO:DATE:
320
0 N
OR
FO
LK
ST
RE
ET
, R
ICH
MO
ND
, V
A 2
323
0
PH
ON
E (
80
4)
79
4-7
555
F
AX
(8
04
) 3
55
-569
0
A
B
C
D
E
1 2 4 53 6 7 8 9 10
F
G
H
I
J
3/3
1/2
02
0 4
:07:3
3 P
M
TELECOM ENLARGED
PLAN
CIT
Y O
F V
IRG
INIA
BE
AC
H
BU
ILD
ING
11
RE
NO
VA
TIO
N
Pro
ject
Ad
dre
ss
TT3.0.1
PW
CN
-18-
0156
CIP
-3-1
74
548507MARCH 31, 2020
REVISIONS
DATE DESCRIPTION
1/2" = 1'-0"2
IT SERVER 045 ENLARGED PLAN
1/2" = 1'-0"1
IT SERVER 045 ENLARGED RCP
TELECOM KEYNOTE LEGEND
NUMBER DESCRIPTION
1 TGB MOUNTED ABOVE LADDER TRAY
2 8' PLYWOOD BACKBOARD PAINTED WHITE
3 12" X 4" BASKET TYPE CABLE TRAY ABOVE ACCESSIBLECEILING
7 26"W X 36"D X 84"H CABINET - TYPICAL
10 6" WIDE VERTICAL CABLE MANAGER
11 12" WIDE VERTICAL CABLE MANAGER
13 12" LADDER TYPE CABLE TRAY
1/2" = 1'-0"3
IT ROOM 123 ENLARGED PLAN
1/2" = 1'-0"4
IT ROOM 123 ENLARGED RCP
1/2" = 1'-0"5
IT ROOM 232 ENLARGED PLAN
1/2" = 1'-0"6
TELECOM OVERALL RCP UPPER - Callout 1
SPLICE HARDWARE ASSEMBLY:GROUND BOLT ASSEMBLY
#6 AWG GROUND WIRE
SHALLOW SUPPORT CHANNEL MOUNTED TO WALL
BASKET TRAY
BASKET TRAY HOLD DOWN PLATE
NOTES:
1. MAXIMUM DISTANCE BETWEEN SUPPORTS SHALL BE NO GREATER THAN 5'.
BEND RADUIS CONTROL BRACKET SHIELD
BASKET TRAY
NOTES:
1. PROVIDE BEND RADIUS CONTROL AT ALL RUNWAY DIRECTION CHANGES AND INTERSECTIONS.
EC TO OUTLET BACKBOX
BASKET TRAY
ALL THREAD
BASKET TRAY SIZED PER PLAN
SHALLOW SUPPORT CHANNEL SECTION
ASSEMBLY HARDWARE
NOTES:
1. MAXIMUM DISTANCE BETWEEN SUPPORTS SHALL BE NO GREATER THAN 5'.
BEND RADIUS WATERFALL BRACKET
BASKET TRAY
NOTES:
1. PROVIDE BEND RADIUS CONTROL AT ALL RUNWAY DIRECTION CHANGES AND INTERSECTIONS.
BASKET TRAY CABLE DROP OUT ASSEMBLY
BASKET TRAY
NOTES:
1. PROVIDE RADIUS DROP CONTROL COMPONENTS AT ALL CABLE ELEVATION CHANGES.
BEND RADIUS WATERFALL BRACKET
BASKET TRAY
NOTES:
1. PROVIDE RADIUS DROP CONTROL COMPONENTS AT ALL CABLE ELEVATION CHANGES.
NOTES:
1. MAXIMUM DISTANCE BETWEEN SUPPORTS SHALL BE NO GREATER THAN 5'.
CABLE BASKET TRAY
CABLE BASKET TRAY TRAPEZE SUPPORT
THREADED ROD
CABLE DROPOUT
WATERFALL FOR CABLE EXIT
FLEXIBLE WIRE BASKET-TYPE CABLETRAY
NOTES:1. PROVIDE RADIUS DROP CONTROL COMPONENTS AT ALL CABLE ELEVATION CHANGES.
BASKET-TYPE CABLE TRAY
SECURITY CABLEUTP CABLE
CABLE DIVIDERS
OPTICAL FIBER CABLE
GENERAL NOTES:
1. WHENEVER POSSIBLE SEPERATE VARIOUS CABLE TYPES WITH PARTITIONS IN CABLE TRAY
CABLE DIVIDERS
MO
SE
LE
YA
RC
HIT
EC
TS
.CO
M
PROJECT NO:DATE:
320
0 N
OR
FO
LK
ST
RE
ET
, R
ICH
MO
ND
, V
A 2
323
0
PH
ON
E (
80
4)
79
4-7
555
F
AX
(8
04
) 3
55
-569
0
A
B
C
D
E
1 2 4 53 6 7 8 9 10
F
G
H
I
J
3/3
1/2
02
0 4
:07:3
6 P
M
TELECOM DETAILS
CIT
Y O
F V
IRG
INIA
BE
AC
H
BU
ILD
ING
11
RE
NO
VA
TIO
N
Pro
ject
Ad
dre
ss
TT5.0.1
PW
CN
-18-
0156
CIP
-3-1
74
548507MARCH 31, 2020
1/16" = 1'-0"1
Basket Cable Tray Attachment & Grounding Detail11/16" = 1'-0"
2Basket PDS Enclosure Cable Attachment1
1/16" = 1'-0"3
Basket Tray Bend Radius11/16" = 1'-0"
4Basket Tray Station Conduit Assembly1
1/16" = 1'-0"5
Basket Tray Trapeze Assembly11/16" = 1'-0"
6Basket Tray Waterfall (end)1
1/16" = 1'-0"7
Basket Tray Waterfall (inside)11/16" = 1'-0"
8Basket Tray Waterfall (Side)1
1/16" = 1'-0"9
Cable Basket Tray Mounting Detail11/16" = 1'-0"
10Cable Exiting From Basket-Type Tray1
1/8" = 1'-0"11
Cable Seperation on Basket Tray1 REVISIONS
DATE DESCRIPTION
COMMUNICATIONS CONDUIT (typ)
HOLE GROUNDING LUG
STRANDED GROUND CABLE
GROUNDING BUSHING
NOTE:
1. CONTRACTOR SHALL BOND EVERY CONDUIT CARRYING COMMUNICATIONS CABLES
GROUND CABLE
H TAP
EQUIPMENT CABINET
VERTICAL POWER STRIP; TWO (2) PER CABINET
STAND-OFF BRACKET
CHANNEL ROD STIFFENER WITH ASSEMBLY COMPONENTS
"UNISTRUT" CHANNEL
ALL THREAD ROD
NOTES:
1. ROD STIFFENER ASSEMBLY REQUIRED ON HANGER RODS THAT HAVE SEISMIC BRACING ATTACHED TO THE HANGER OR TRAPEZE ASSEMBLY, UNLESS OTHERWISE NOTED BY CODE.
13
" M
AX
. (U
ON
)1
3"
MA
X. (U
ON
)1
3"
MA
X. (U
ON
)
6"
MA
x.
NOTE:
1. UTILIZE ROD STIFFENER ASSEMBLY AS REQUIRED ON HANGER RODS THAT HAVE SEISMIC BRACKING ATTACHED TO THE HANGER OR TRAPEZE ASSEMBLY, UNLESS OTHERWISE NOTED BY CODE
2. MAXIMUM DISTANCE BETWEEN SUPPORTS SHALL BE NO GREATER THAN 5'.
CABLE RUNWAY SECTION
CABLE RUNWAY - ROD MOUNTING HARDWARE
THREADED ROD - SIZED PER STRUCTURAL ENGINEER REQUIREMENTS
THREADED ROD ATTACHMENT HARDWARE
CIRCUITS TO BE INSTALLED ON THE OVERHEAD CABLE RUNWAY IN J-BOX MOUNTED ON THE WALL AT THE END OF THE RACKS AT 8' AFF. CAP WIRES IN J-BOX BY ELECTRICAL CONTRACTOR.
20AMP 110V, W/ TWIST LOCK RECEPTACLE BY ELECTRICAL CONTRACTOR.
LADDER TYPE CABLE TRAY BY LOW VOLTAGE CONTRACTOR.
COMPONENT RACK BY LOW VOLTAGE CONTRACTOR.
20AMP 110V, W/ TWIST LOCK RECEPTACLE BY ELECTRICAL CONTRACTOR.
CIRCUITS TO BE INSTALLED ON THE OVERHEAD CABLE TRAY IN J-BOX MOUNTED ON THE WALL AT THE END OF THE RACKS AT 8' AFF. CAP WIRES IN J-BOX.
20AMP 110V, W/ TWIST-LOCK RECEPTACLE
LADDER TYPE CABLE TRAY
CONTRACTOR TO REMOVE BLADE PLUG AND SUBSTITUTE TWIST-LOCK PLUG (TYPICAL)
STANDOFF BRACKET
MO
SE
LE
YA
RC
HIT
EC
TS
.CO
M
PROJECT NO:DATE:
320
0 N
OR
FO
LK
ST
RE
ET
, R
ICH
MO
ND
, V
A 2
323
0
PH
ON
E (
80
4)
79
4-7
555
F
AX
(8
04
) 3
55
-569
0
A
B
C
D
E
1 2 4 53 6 7 8 9 10
F
G
H
I
J
3/3
1/2
02
0 4
:07:3
9 P
M
TELECOM DETAILS
CIT
Y O
F V
IRG
INIA
BE
AC
H
BU
ILD
ING
11
RE
NO
VA
TIO
N
Pro
ject
Ad
dre
ss
TT5.0.2
PW
CN
-18-
0156
CIP
-3-1
74
548507MARCH 31, 2020
1/8" = 1'-0"1
Bonding Detail11/8" = 1'-0"
2Bonding Ground Cables w/ H-Tap1
1/16" = 1'-0"3
Cabinet-Vertical Power strip Assembly1
1/8" = 1'-0"4
Cable Runway Vertical Rod Stiffener Support Assembly11/8" = 1'-0"
5Cable Runway/Tray Threaded Rod Support1
1/8" = 1'-0"6
Cabletray/Plugmold mounting with TR1
1/8" = 1'-0"7
Equipment Rack Detail
REVISIONS
DATE DESCRIPTION
2" HIGH RED STENCILED LETTERING
CLEAR 3/8" THICK FLEXIGLASS COVER
5/8"-11 X 1-1/2" CONT. THREADED ROD (typ)
2-3/4" INSULATOR
5/8" DIAMETER (typ)
9/16" (40) PLACES
5/8"-11 X 1" H.H.C.S.
7/16" DIAMETER (20) PLACES
LOCK WASHER
TBB
2-3/4" INSULATOR
5/8" DIAMETER (typ)
5/8"-11 X 1" H.H.C.S.
2-3/4" INSULATOR
3/8 " ALL THREAD ROD (NEWTON 3022-11) HANGERS 4'-0" O.C. UP TO STRUCTURAL STEEL (SEE STRUCTURAL DRAWINGS) IN EQUIPMENT ROOM. INSTALL ON BOTH SIDES OF CABLE LADDER.
AUX. CABLE BRACKET WALL ANGLE
J-BOLT KIT
CABLE RING
JUNCTION KIT
#2/0 INSULATED COPPER EQUIPMENT GROUND ON RACK
CABLE BRACKET
RUNWAY SPLICE
#2/0 INSULATED COPPER EQUIPMENT GROUND ROUTED BENEATH RACK
ROUTE TO TBB
CABLE LADDER DETAIL NOTES:
1. ALL CABLE LADDER SECTIONS ARE TO BE BOUNDED TOGETHER, SEE DETAIL.
2. ALL UNISTRUT SUPPORTING CABLE TAPS ARE TO BE BONDED AT EACH INTERSECTION OR SECTION.
3. SEE ARCHITECTURAL PLANS FOR MOUNTING HEIGHT.
CABLE LADDER INTERIOR GROUNDING NOTES:
1. INTERIOR GROUNDING SHALL BE PROVIDED ON THE CABLE LADDER AS SHOWN ON DRAWINGS.
2. ALL INTERIOR GROUNDING AND CROSS RUNS SHALL BE FURNISHED AND INSTALLED BY THE CONTRACTOR. SEE GROUNDING DETAIL DRAWING FOR GROUNDING DETAILS PERTAINING TO THESE NOTES.
3. CROSS RUNS SHALL BE CONNECTED TO THE INTERNAL RING.
4. CROSS RUNS SHALL BE BONDED TOGETHER USING A MEDIUM CROSS RUN CLAMP FOR NO. 2/0 WIRE. THOMPSON LIGHTING PROTECTION NO. 125 OR AS APPROVED EQUIVALENT.
5. CROSS RUNS SHALL BE ATTACHED UNDERNEATH THE CABLE LADDER USING APPROVED DEVICES.
6. CABLE LADDER HEIGHTS TO BE SHOWN ON ARCHITECTS DRAWINGS. CONTRACTOR SHALL CONFIRM THE REQUIRED HEIGHTS AFF. AS SHOWN ON THE CABLE LADDER PLANS BEFORE INSTALLING THE CABLE LADDER AND INSTALLING GROUND SYSTEM CROSS RUNS.
7. CABLE LADDER AND UNISTRUT SECTIONS SHALL BE BONDED TOGETHER USING BRAIDED TINNED COPPER STRAPS.
RUNWAY BRACKET
TO BUILDING MAIN GROUND
TO TENENT MAIN ELECTRICAL PANEL
TO LOCAL ELECTRICAL PANEL
2 HOLE GROUND LUG (typ.)
TELECOMMUNICATIONS GROUND BAR (TMGB) COMPLAINT WITH J-STD-607-A
6"
TYP. 16" WALL STUD SPACING
J-BOX BRIDGE SUPPORT
DUAL GANG QUAD FOR POWER
(1)
X 1
-1/4
" S
TU
B-U
P
WA
LL S
TU
D
WA
LL S
TU
D
W/ SINGLE GANG MUD-RING FOR
TYPICAL SEPARATION
MO
SE
LE
YA
RC
HIT
EC
TS
.CO
M
PROJECT NO:DATE:
320
0 N
OR
FO
LK
ST
RE
ET
, R
ICH
MO
ND
, V
A 2
323
0
PH
ON
E (
80
4)
79
4-7
555
F
AX
(8
04
) 3
55
-569
0
A
B
C
D
E
1 2 4 53 6 7 8 9 10
F
G
H
I
J
3/3
1/2
02
0 4
:07:4
0 P
M
TELECOM DETAILS
CIT
Y O
F V
IRG
INIA
BE
AC
H
BU
ILD
ING
11
RE
NO
VA
TIO
N
Pro
ject
Ad
dre
ss
TT5.0.3
PW
CN
-18-
0156
CIP
-3-1
74
548507MARCH 31, 2020
1/4" = 1'-0"1
Grounding Busbar11/4" = 1'-0"
2Ladder Rack Assembly (typ)1
1/8" = 1'-0"4
Telecommunications Main Ground Bar Detail (TMGB)1
3/8" = 1'-0"3
WOA Wall Box Detail
REVISIONS
DATE DESCRIPTION
DRAWING LIST:
AFC AT FINISHED CEILING
AFF ABOVE FINISHED FLOOR
AFP ABOVE FINISHED PLATFORM OR RAISED FLOOR
AS ABOVE SLAB
ATS ABOVE TABLE SURFACE
AV AUDIOVISUAL
CLG CEILING
EMT
FP FLAT PANEL
GND GROUND
ID INSIDE DIAMETER
IDF INTERMEDIATE DISTRIBUTION FRAME
LAN LOCAL AREA NETWORK
MAX MAXIMUM
MDF MAIN DISTRIBUTION FRAME
MIN MINIMUM
MM MULTIMODE
MTD MOUNTED
MTER MAIN TELECOMMUNICATIONS EQUIPMENT ROOM
NIC NOT IN CONTRACT
NTS NOT TO SCALE
OD OUTSIDE DIAMETER
OFE OWNER FURNISHED EQUIPMENT
OSP OUTSIDE PLANT
PB PULLBOX
SM SINGLE MODE
ST STRAND
STP SHIELDED TWISTED PAIR
TBD TO BE DETERMINED
TEMP TEMPORARY
TGB TELECOMMUNICATIONS GROUND BAR
TR TELECOMMUNICATIONS ROOM
TSER TELECOMMUNICATIONS SERVICE ENTRANCE ROOM
TYP TYPICAL
UON UNLESS OTHERWISE NOTED
UPS UNINTERRUPTIBLE POWER SUPPLY
UTP UNSHIELDED TWISTED PAIR
VIF VERIFY IN FIELD
VOIP VOICE OVER INTERNET PROTOCOL
WAN WIDE AREA NETWORK
WAP WIRELESS ACCESS POINT
WP WATERPROOF
WW WIREWAY
1.
2.
3.
4.
4.1.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
16.
17.
18.
19.
20.
21.
MINIMUM ACCEPTABLE DISTANCE BETWEEN PARALLEL AV AND POWER CONDUITS
AV CONDUITPOWER
CONDUIT
COMBINED AMPACITY OF ALL PHASE CONDUCTORS IN POWER CONDUIT
UNDER 60A 60A 120A 240A 400A
EMT EMT 2 FT. 3 FT. 4 FT. NA NA
EMT RIGID STEEL 4 IN. 8 IN. 1 FT. 2 FT. 4 FT.
RIGID STEEL RIGID STEEL1 IN. 2 IN. 4 IN. 8 IN. 16 IN.
DEFINITION OF TERMS
LEGEND FOR SCOPE OF WORK BETWEEN TRADES:
GC = GENERAL CONTRACTOR
EC = ELECTRICAL CONTRACTOR
AV = AUDIOVISUAL CONTRACTOR
O = OWNER
ST = STRUCTURED CABLING, OR TELECOMMUNICATIONS CONTRACTOR
NO LARGE POWER TRANSFORMERS OR MOTORS SHOULD BE LOCATED WITHIN 50 FEET OF AV EQUIPMENT SPACES.
ALL AV CABLING THAT IS RUN OPEN-WIRE SHALL BE SUPPORTED FROM J-HOOKS NO GREATER THAN 3 FEET APART. NO CABLE IS TO BE UNSUPPORTED OR LAID OVER CEILING TILES, BLACK IRON, OR OTHER CEILING MEMBERS.
THE METHOD OF INSTALLATION OF BOXES IN WALLS, AND THE METHOD OF PASSAGE OF CONDUITS AND WIREWAYS THROUGH ACOUSTICALLY SENSITIVE WALLS SHALL BE COORDINATED WITH THE ACOUSTICAL CONSULTANT.
INSTALL FIRESTOP TO ALL SLAB AND WALL PENETRATIONS PROVIDED FOR THE INSTALLATION OF CABLE AND CONDUIT AS REQUIRED TO MAINTAIN FIRE RATING OF SLAB OR WALL. REVIEW ARCHITECT'S PLANS FOR PARTITION TYPES. THE CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING THE FIRE RATING OF ALL WALLS AND FLOORS HAVING CABLING PENETRATIONS, COORDINATE SEALANT INSTALLATION WITH WORK OF OTHER TRADES. REFER TO ELECTRICAL SPECIFICATIONS FOR MATERIAL AND INSTALLATION PARAMETERS.
ALL POWER, WIREWAYS, AND JUNCTION BOXES ARE TO BE REVIEWED BY ELECTRICAL ENGINEER FOR CODE AND SAFETY COMPLIANCE.
ALL OVERHEAD RIGGING REQUIREMENTS ARE TO BE REVIEWED AND STAMPED FOR APPROVAL BY LICENSED STRUCTURAL ENGINEER FOR CODE AND SAFETY COMPLIANCE.
POWER BREAKER AND DISTRIBUTION PANELS ARE SIZED AND SPECIFIED BY THE ELECTRICAL ENGINEER.
ALL CABLE TRAY THAT IS SURFACE-MOUNTED ON SLAB BELOW RAISED FLOOR OR ABOVE EQUIPMENT RACKS SHALL BE SECURELY FASTENED AND LEFT OPEN FOR CABLE ACCESS.
POWER FOR AV AND RELATED SYSTEMS SHALL USE AN EIA/TIA 607 COMPLIANT GROUNDING SYSTEM, DESIGNED BY THE ELECTRICAL ENGINEER. REFER TO AV DETAIL SHEETS FOR ADDITIONAL GROUNDING REQUIREMENTS IF APPLICABLE.
ALL AV-RELATED EMPTY CONDUIT SHALL BE REAMED, CLEANED, CAPPED (WHERE APPROPRIATE), TAGGED, AND FURNISHED WITH PULL WIRES.
WHERE EXACT DIMENSIONS ARE NOT INDICATED, THE SCALE OF THIS DRAWING IS SUFFICIENTLY ACCURATE FOR DETERMINING THE LOCATION OF EQUIPMENT, JUNCTION BOXES, OUTLET BOXES, WIREWAYS, PANELS, ETC. WHERE EXACT DIMENSIONS ARE INDICATED, THE REFERENCE SURFACE SHALL BE THE FINAL FINISHED SURFACE INCLUDING ANY ACOUSTICAL TREATMENT. ROOM DIMENSIONS ON THE DRAWINGS HAVE BEEN TAKEN FROM PRELIMINARY ARCHITECTURAL DRAWINGS. ALL DIMENSIONS MUST BE VERIFIED AND ANY DEVIATIONS CAUSING CHANGES MUST BE COORDINATED WITH SHEN MILSOM & WILKE, LLC.
NOTIFY OWNER'S REPRESENTATIVES OF ANY DISCREPANCIES BETWEEN THE EXISTING CONDITIONS AND THE AV DRAWINGS. OBTAIN CLARIFICATION BEFORE PROCEEDING WITH WORK.
ALL AV DEVICES SHALL BE SECURELY MOUNTED PLUMB AND STRAIGHT TO WALLS, FLOORS, OR RACKS PER THE MANUFACTURER'S RECOMMENDED MOUNTING PRACTICE.
THERE SHALL BE A MINIMUM OF ONE PULL BOX FOR EVERY 100' OF STRAIGHT EMPTY AV-RELATED CONDUIT AND ONE PULL BOX WHERE THERE ARE MORE THAN TWO 90° BENDS OR LESSER BENDS TOTALING 180° IN A CONDUIT RUN.
MAINTAIN MINIMUM BEND RADIUS OF 10X OD FOR ALL AV-RELATED CONDUITS.
LIGHTING DESIGNER TO PROVIDE LIGHTING ON A SEPARATE DIMMING ZONE AT THE SCREEN/DISPLAY DEVICE TO ENSURE GOOD CONTRAST AND IMAGE SHARPNESS.
AV CONTRACTOR SHALL RESTORE CEILINGS, WALLS AND ANY OTHER SURFACES AFFECTED BY THEIR WORK PRIOR TO COMPLETION OF WORK WITH LIKE MATERIALS TO MATCH EXISTING CONSTRUCTION.
REFER TO AV ELECTRICAL PLANS AND/OR RISER DIAGRAMS FOR EMPTY CONDUIT SIZING.
ALL POWER CIRCUITS INDICATED IN THIS DRAWING SET TO BE PROVIDED BY DEDICATED BREAKER PANEL(S). NO NON-AV CIRCUITS TO BE FED FROM DEDICATED AV BREAKER PANEL(S).
POWER FOR ALL AV SERVICES IN EACH DESIGNATED SPACE SHALL BE ON THE SAME ELECTRICAL PHASE, AND THIS PHASE SHALL NOT INCLUDE MOTORS, APPLIANCES, OR ANY OTHER SOURCE THAT CAN CAUSE SIGNAL INTERFERENCE.
GROUNDING: GROUND COMMUNICATIONS SYSTEMS AND EQUIPMENT IN ACCORDANCE WITH ANSI/TIA/EIA-807 GROUNDING STANDARDS AND APPLICABLE NEC REQUIREMENTS EXCEPT WHERE DRAWINGS OR SPECIFICATIONS EXCEED NEC REQUIREMENTS. ALL RACKS, METALLIC BACKBOARDS, CABLE SHEATHS, CABLE TRAYS, ETC. ENTERING OR RESIDING IN TECHNICAL EQUIPMENT SPACES SHALL BE GROUNDED TO THEIR RESPECTIVE GROUND SYSTEM USING A MINIMUM OF #6 AWG STRANDED COPPER BONDING CONDUCTOR AND COMPRESSOR CONNECTORS. ALL WIRES USED FOR TECHNICAL POWER SYSTEMS GROUNDING PURPOSES SHALL BE IDENTIFIED WITH GREEN INSULATION OR IDENTIFIED AT EACH TERMINATION POINT WITH A WRAP OF GREEN TAPE. ALL CABLES AND BUS BARS SHALL BE IDENTIFIED AND LABELED "TECHNICAL POWER SYSTEM GROUND".
CONDUIT STUBS: PROVIDE NYLON BUSHING ON ALL CONDUIT STUBS AND NON-TERMINATING CONDUIT ENDS TO PROTECT WIRE PULLS.
JUNCTION BOX COVERS: UNLESS OTHERWISE NOTED, ALL JUNCTION BOXES MUST BE PROVIDED WITH A COVER. WHERE RAISED DEVICE COVERS ARE SPECIFIED, MATCH COVER DEPTH TO WALL THICKNESS. WHERE JUNCTION BOXES ARE MOUNTED AT OR ABOVE FINISHED CEILING HEIGHT, INSTALL JUNCTION BOXES WITH OPEN SIDE FACING DOWN.
POWER RECEPTICALS: TECHNICAL POWER RECEPTICALS, INCLUDING THOSE WITHIN FLOOR BOXES, WALL BOXES, OR CEILING BOXES, SHALL BE PROVIDED BY THE BUIDING CONTRACTOR AND APPEAR ON THE ELECTRICAL DRAWINGS. TECHNICAL POWER RECEPTACLES IN RELATION TO TECHNOLOGY INFRASTRUCTURE IS CRITICAL. REFER TO THE ELECTRICAL DRAWINGS FOR COMPLETE POWER LAYOUTS AND CIRCUITING DETAILS
NETWORK OUTLETS FOR AUDIOVISUAL SYSTEMS: ALL NETWORK OUTLETS SHALL APPEAR ON THE NETWORK DRAWINGS. NETWORK SERVICES APPEARING ON THE AUDIOVISUAL DRAWINGS ARE REPRESENTATIVE OF NETWORK CONNECTIVITY REQUIREMENTS IN SUPPORT OF AUDIOVISUAL SYSTEMS, AS THE LOCATION OF NETWORK SERVICES IN RELATION TO TECHNOLOGY INFRASTRUCTURE IS CRITICAL. REFER TO THE STRUCTURED CABLING SYSTEM SPECIFICATIONS AND DRAWINGS FOR ADDITIONAL INFORMATION.
POWER AND DATA REQUIREMENTS SHOWN FOR REFERENCE ONLY AND ARE NOT FOR CONSTRUCTION. COORDINATE WITH ELECTRICAL ENGINEER, ARCHITECT AND TELECOM DESIGNER DRAWINGS FOR LOCATION OF ALL OUTLETS IN THIS DRAWING SET.
WHERE POWER CIRCUITS ARE SHOWN TERMINATING IN JUNCTION BOXES WITHOUT RECEPTACLES, THE WIRES SHALL BE TAPED AND THE BOXES COVERED. THESE CIRCUITS WILL BE CONNECTED BY OTHERS DURING INSTALLATION OF THE AV SYSTEMS EQUIPMENT.
EMPTY CONDUIT RUNS ON THESE DRAWINGS SHOW ONLY INTERCONNECTION BETWEEN TERMINATION POINTS. THE EXACT PATH OF CONDUIT IS TO BE DETERMINED BY THE COORDINATE PATHWAYS FOR ALL AV RELATED DEVICES WITH ARCHITECTURAL AND ELECTRICAL PLANS.
HIGH LEVEL/HIGH CURRENT FEEDS (SUCH AS FOR POWER DISTRIBUTION PANELS, LIGHTING, AND BRANCH CIRCUITS,) ARE NOT TO BE RUN PARALLEL WITH AUDIO/VIDEO CONDUITS OR CABLING. IF HIGH LEVEL/HIGH CURRENT FEEDS MUST RUN PARALLEL TO AUDIO/VIDEO CONDUITS OR CABLING, MINIMUM SEPARATION MUST BE MAINTAINED ACCORDING TO THE FOLLOWING TABLE. "NA" INDICATES THAT THE USE SHOULD BE AVOIDED. SPACINGS ASSUME THAT POWER CONDUCTORS WILL NOT BE TWISTED PAIRS. CLOSER SPACINGS CAN BE USED IF POWER CONDUCTORS ARE TWISTED PAIRS.
FURNISH - TO PURCHASE AND DELIVER TO THE PROJECT SITE COMPLETE WITH EVERY NECESSARY APPURTENANCE AND SUPPORT. PURCHASING SHALL INCLUDE PAYMENT OF ALL SALES TAXES AND OTHER SURCHARGES AS MAY BE REQUIRED TO ASSURE THAT PURCHASED ITEMS ARE FREE OF ALL LIENS. CLAIMS, OR ENCUMBRANCES.
INSTALL - TO UNLOAD AT THE DELIVERY POINT AT THE SITE AND PERFORM EVERY OPERATION NECESSARY TO ESTABLISH SECURE MOUNTING AND CORRECT OPERATION AT THE PROPER LOCATION IN THE PROJECT, ALL AS PART OF THE WORK.
PROVIDE - TO FURNISH AND INSTALL
ELECTRICAL FLOOR MOUNTED SYMBOLS: ELECTRICAL CEILING MOUNTED SYMBOLS: NOTES: ABBREVIATIONS:
ELECTRICAL WALL MOUNTED SYMBOLS: SCOPE OF WORK BETWEEN TRADES:
EC
ELECTRICAL METALLIC TUBING (WITH PULL STRING)
EMPTY CONDUIT
22.
JUNCTION BOX, 6" x 6" x 4" DEEP, UON, WITH COVER PLATE FOR AV RECEPTACLES. FLUSH MOUNTED IN FINISHED FLOOR OR SURFACE MOUNTED TO SLAB BELOW RAISED FLOOR.
FLOOR BOX WITH DIVIDED COMPARTMENTS FOR AV, DATA AND POWER. FLUSH MOUNTED IN FINISHED FLOOR WITH HINGED SCRUB WATER RATED COVER PLATE AND CARPET FLANGE, OoN (VERIFY FINISH PLATE COLOR WITH ARCHITECT). SEE DETAIL. FSR FLOOR BOX MODEL FL-500P (4" DEEP), UON. REFER TO POWER AND DATA SYMBOL FOR RELATED REQUIREMENTS.
(* = NUMBER OF POWER CIRCUITS)(# = NUMBER OF DATA DROPS)
JUNCTION BOX, 2.5" DEEP, FOR AV RECEPTACLES. SINGLE GANG, UON. MOUNT FLUSH WITH FINISHED WALL TREATMENT AT BUILDING STANDARD BASE OUTLET HEIGHT, UON.(* = NUMBER OF GANGS)
FLAT PANEL DISPLAY JUNCTION BOX WITH SEPARATE COMPARTMENTS FOR AV, DATA, AND POWER. SEE DETAIL. CHIEF BACK BOX MODEL PAC 526 SERIES (4.0" DEEP), UON. MOUNT FLUSH WITH FINISHED WALL TREATMENT. SEE ELEVATION. AT 60" AFF, UON. REFER TO POWER AND DATA DESCRIPTIONS FOR RELATED REQUIREMENTS.
(# = NUMBER OF DATA DROPS)(* = NUMBER OF POWER OUTLETS)
JUNCTION BOX, 2.5" DEEP, FOR AV RECEPTACLES SINGLE GANG, UON. FLUSH MOUNTED IN FINISHED CEILING.(# = NUMBER OF GANGS)
JUNCTION BOX, 2.5" DEEP, PROVIDE DOUBLE-GANG BOX, UON, FOR AVRECEPTACLES. SURFACE MOUNTED TO SLAB ABOVE FINISHED CEILING.(# = NUMBER OF GANGS)
SCREW COVER BOX FOR AV SIGNAL CABLE AND CONDUIT TERMINATION. SIZED BYELECTRICAL ENGINEER. SURFACE MOUNTED TO SLAB ABOVE FINISHED CEILING.
12" x 4", UON, CABLE TRAY. REFER TO AV NOTES FOR ADDITIONAL INFORMATION.
LOW VOLTAGE CONTROLLER FOR PROJECTION SCREEN OR SHADE CONTROL.SUPPLIED WITH SCREEN. SURFACE MOUNTED TO SLAB ABOVE FINISHED CEILING. ACCESS PANEL TO CONTROLLER MUST BE PROVIDED FOR MAINTENANCE.
CONDUIT STUB-UP INTO FURNITURE.
POWER RECEPTACLE, DUPLEX, 120 VAC, 15 AMP CIRCUIT, UON. FLUSH MOUNTED IN FINISHED FLOOR OR SURFACE MOUNTED TO SLAB BELOW RAISED FLOOR. REFER TO AV NOTES FOR ADDITIONAL INFORMATION.
POWER RECEPTACLE, QUAD, 120 VAC, SINGLE DEDICATED 20 AMP CIRCUIT.MOUNTED IN FINISHED FLOOR OR SURFACE MOUNTED TO SLAB BELOW RAISED FLOOR. REFER TO AV NOTES FOR ADDITIONAL INFORMATION.(* = NUMBER OF DEDICATED POWER CIRCUITS)
JUNCTION BOX FOR POWER, 120 VAC, SINGLE DEDICATED 20 AMP CIRCUIT BY THE ELECTRICAL ENGINEER. FLUSH MOUNTED IN FINISHED FLOOR OR SURFACE MOUNTED TO SLAB BELOW RAISED FLOOR. REFER TO AV NOTES FOR ADDITIONAL INFORMATION.(* = NUMBER OF DEDICATED POWER CIRCUITS)
STANDARD DATA OUTLET FLUSH MOUNTED IN FINISHED FLOOR, FLOOR BOX OR SURFACE MOUNTED IN FINISHED FLOOR, FLOOR BOX OR SURFACE MOUNTED TO SLAB BELOW RAISED FLOOR. REFER TO AV NOTES FOR ADDITIONAL INFORMATION. (# = NUMBER OF DATA DROPS)
SCREW COVER BOX FOR AV SIGNAL CABLE AND CONDUIT TERMINATION. SIZED BY ELECTRICAL ENGINEER. MOUNT FLUSH WITH FINISHED WALL TREATMENT ATSTANDARD BASE OUTLET HEIGHT, UON.
WALL BOX TYPE 1, 6" x 6" x 4" DEEP, FOR AV RECEPTACLES. MOUNT FLUSH WITH FINISHED WALL TREATMENT AT BUILDING STANDARD BASE OUTLET HEIGHT, UON.
WALL BOX TYPE 2, 12" x 12" x 4" DEEP, FOR AV RECEPTACLES. MOUNT FLUSH WITH FINISHED WALL TREATMENT AT BUILDING STANDARD BASE OUTLET HEIGHT, UON.
WALL SWITCH FOR RAISE/LOWER/STOP OF PROJECTION SCREEN AND/OR FOR VIDEO PROJECTOR LIFT. MOUNT AT STANDARD SWITCH HEIGHT, UON.
POWER RECEPTACLE, DUPLEX, 120 VAC, 15 AMP CIRCUIT. MOUNT AT BUILDING STANDARD BASE ELECTRICAL HEIGHT, UON. REFER TO AV NOTES FOR ADDITIONAL INFORMATION.
POWER RECEPTACLE, QUAD, 120 VAC, SINGLE DEDICATED 20 AMP CIRCUIT. MOUNTAT BUILDING STANDARD BASE ELECTRICAL HEIGHT, UON. REFER TO AV NOTES FOR ADDITIONAL INFORMATION.(* = NUMBER OF DEDICATED POWER CIRCUITS)
POWER RECEPTACLE, 208 VAC, SINGLE DEDICATED 30 AMP CIRCUIT. MOUNT AT BUILDING STANDARD BASE ELECTRICAL HEIGHT, UON. REFER TO AV NOTES FOR ADDITIONAL INFORMATION.
JUNCTION BOX FOR POWER, 120 VAC, 20 AMP, SIZED BY THE ELECTRICAL ENGINEER. MOUNT AT BUILDING STANDARD BASE ELECTRICAL HEIGHT, UON. REFER TO AV NOTES FOR ADDITIONAL INFORMATION.(* = NUMBER OF DEDICATED CIRCUITS)
STANDARD INFORMATION OUTLET. MOUNT AT BUILDING STANDARD BASE ELECTRICAL HEIGHT, UON. REFER TO AV NOTES FOR ADDITIONAL INFORMATION.(# = NUMBER OF DATA DROPS)
AUDIOVISUAL CONTROL PANEL OUTLET. REFER TO DETAIL. TRIPLE-GANG BOX WITH DOUBLE GANG REDUCTION RING AND SINGLE POE DATA DROP, UON. MOUNT AT 48" AFF, UON. REFER TO AV NOTES FOR ADDITIONAL INFORMATION.(# = NUMBER OF DATA DROPS)
AUDIOVISUAL ROOM SCHEDULRE OUTLET. REFER TO DETAIL. DOUBLE-GANG BOX WITH SINGLE GANG REDUCTION RING AND SINGLE POE DATA DROP, UON. MOUNT AT 48" AFF, UON. REFER TO AV NOTES FOR ADDITIONAL INFORMATION.(# = NUMBER OF DATA DROPS)
DATA OUTLET FOR AUDIO NETWORK. PROVIDE DROPS WITH NEUTRIK ETHERCON CHASSIS CONNECTORS. MOUNT AT BUILDING STANDARD BASE ELECTRICAL HEIGHT, UON. REFER TO AV NOTES FOR ADDITIONAL INFORMATION. REFER TO DETAIL.(# = NUMBER OF DATA DROPS)
RS232 INTERFACE FOR LIGHTING AND SHADES. MOUNT AT BUILDING STANDARD BASE OUTLET HEIGHT, UON. REFER TO ELECTRICAL DRAWINGS FOR LIGHTING AND SHADE CONTROL SPECIFICATIONS.
CATV OUTLET WITH A SINGLE RF DROP, UON. MOUNT AT BUILDING STANDARD BASEOUTLET HEIGHT, UON.(# = NUMBER OF CATV DROPS)
POWER RECEPTACLE, DUPLEX, 120 VAC, 15 AMP, UON. FLUSH MOUNTED IN FINISHED CEILING. REFER TO AV NOTES FOR ADDITIONAL INFORMATION.(# = NUMBER OF DEDICATED POWER CIRCUITS)
POWER RECEPTACLE, QUAD, 120 VAC, SINGLE DEDICATED 20 AMP CIRCUIT. FLUSH MOUNTED IN FINISHED CEILING. REFER TO AV NOTES FOR ADDITIONAL INFORMATION.(# = NUMBER OF DEDICATED POWER CIRCUITS)
POWER RECEPTACLE, 208 VAC, SINGLE DEDICATED 30 AMP CIRCUIT. FLUSH MOUNTED IN FINISHED CEILING. REFER TO AV NOTES FOR ADDITIONAL INFORMATION.
POWER RECEPTACLE, DUPLEX, 120 VAC, 15 AMP, OON. SURFACE MOUNTED TO SLAB ABOVE FINISHED CEILING. REFER TO AV NOTES FOR ADDITIONAL INFORMATION.(# = NUMBER OF DEDICATED POWER CIRCUITS)
POWER RECEPTACLE, QUAD, 120 VAC, SINGLE DEDICATED 20 AMP CIRCUIT. SURFACE MOUNTED TO SLAB ABOVE FINISHED CEILING. REFER TO AV NOTES FOR ADDITIONAL INFORMATION.(# = NUMBER OF DEDICATED POWER CIRCUITS)
JUNCTION BOX FOR POWER, 120 VAC, SINGLE DEDICATED 20 AMP CIRCUIT, SIZED BY THE ELECTRICAL ENGINEER. SURFACE MOUNTED TO SLAB ABOVE FINISHED CEILING. REFER TO AV NOTES FOR ADDITIONAL INFORMATION.(# = NUMBER OF DEDICATED POWER CIRCUITS)
DATA OUTLET FLUSH MOUNTED IN FINISHED CEILING. REFER TO AV NOTES FOR ADDITIONAL INFORMATION.(# = NUMBER OF DATA DROPS)
DATA OUTLET SURFACE MOUNTED TO SLAB ABOVE FINISHED CEILING. REFER TO AV NOTES FOR ADDITIONAL INFORMATION.(# = NUMBER OF DATA DROPS)
RS232 INTERFACE FOR LIGHTING AND SHADES. SURFACE MOUNTED TO SLAB ABOVE FINISHED CEILING.
CATV OUTLET WITH A SINGLE RF DROP, UON. SURFACE MOUNTED TO SLAB ABOVE FINISHED CEILING.(# = NUMBER OF CATV DROPS)
SPEAKER LOCATION, SPEALER TYPE [1], SINGLE ZONEM OON. SHOW DETAIL. SHOWN FOR COORDINATION PURPOSES ONLY.(* = SPEAKER ZONE)
CUSTOM SPEAKER BACK BOX. FLUSH MOUNTED IN FINISHED CEILING.
MANUFACTURER BACK BOX MODEL MODEL# (X.X" DEEP). SPEAKER DRIVER TO BE INSTALLED AT A LATER DATE BY AV CONTRACTOR.(* = SPEAKER ZONE)
23.
FB
# *
J
#
FP
*#
RL
SC
W1
W2
*
#
*
CP#
RS#
AN#
J
#
SC
LVC
*
*
#
#
P
#
#
#
LS
S1
S2
P
*
J*
P*
TV
#
J
#
LS
TV#
ST
NOTES:
24.
25.
26.
27.
28.
A AMPERES
AC ABOVE COUNTER
AWG AMERICAN WIRE GAGE
C CONDUIT
CAT-3 TIA/EIA CATEGORY 3 RATED
CAT-5E TIA/EIA CATEGORY 5 E RATED
CAT-6A TIA/EIA CATEGORY 6A RATED
CAT-6E TIA/EIA CATEGORY 6 E RATED
CB CEILING BOX
CCTV CLOSED CIRCUIT TELEVISION
CKT CIRCUIT
COAX COAXIAL CABLE
CL CENTER LINE
COND CONDUCTOR
EM EMERGENCY
CP CONSOLIDATION POINT
CU COPPER
DVR DIGITAL VIDEO RECORDER
DWG DRAWING
EC CONDUCTOR
EX EXISTING
F/UTP FOILED/UNSHIELDED TWISTED PAIR
VP VAPOR PROOF
W WATTS
WM WIRE MANAGEMENT
WS WORKSTATION
WT WATER TIGHT
XFRM TRANSFORMER
TV TELEVISION
VA VOLT/AMPERS
VM VOLTMETER
TS TAMPER SWITCH
SP SPEAKER
SB SPEAKER BACK BOX
PR PAIR
PNL PANEL
POE POWER OVER ETHERNET
PRJ PROJECTOR
PTZ PAN/TILT/ZOOM
RM ROOM
RW RACEWAY
SC SCREW COVER BOX
PBX PRIVATE BRANCH EXCHANGE
PP PATCH PANEL
PA PUBLIC ADDRESS
NO NORMALLY OPEN
NO. NUMBER
NID NETWORK INTERFACE DEVICE
N NEUTRAL
NC NORMALLY CLOSED
MH MANHOLE
MER MECHANICAL EQUIPMENT ROOM
MC MAIN CROSS CONNECT
MIC MICROPHONE
LV LOW VOLTAGE
HC HUNG CEILING
HZ HERTZ
FA FIRE ALARM
FACP FIRE ALARM CONTROL PANEL
FB FLOOR BOX
FO FIBER OPTIC
SCOPE OF WORK FURNISH INSTALL
IN-WALL BLOCKING SUPPORT FOR AV MOUNTS GC GC
MOTORIZED PROJECTION SCREENS GC GC
PROJECTION GLASS GC GC
WALL AND CEILING SPEAKER CUTOUTS
FURNITURE CUTOUTS FOR AV EQUIPMENT (UNLESS PROVIDED BY FURNITURE PROVIDER)
MOTORIZED PROJECTION LIFTS AV GC
KINDORF AND/OR BLACK IRON AS REQUIRED FOR CEILING MOUNTED AV DEVICES
GC GC
CABLE CONTAINMENT INCLUDING: EC EC
- CONDUIT WITH MEASURED PULLSTRINGS EC EC
- CABLETRAY, LADDERTRAY, AND WIREWAYS EC EC
- FLOORBOXES EC EC
- JUNCTION BOXES, PULL BOXES, AND BACKBOXES EC EC
POWER OUTLETS EC EC
DEDICATED DISTRIBUTION PANELS, LOAD CENTERS, AND POWER ISOLATION TRANSFORMERS
EC EC
AV CABLING (LOW VOLTAGE) AV AV
AV TERMINATIONS AV AV
CUSTOM ENGRAVED AV COVER PLATES AV AV
J-HOOKS AND OTHER SUPPORTS REQUIRED FOR OPEN-RUN AV CABLING
AV AV
AV DEVICE WALL MOUNTS AV AV
AV DEVICES (AS DESCRIBED IN THE AV BID DOCS) AV AV
VOICE/DATA NETWORK CABLING (FIBER AND TWISTED PAIR)
ST ST
VOICE/DATA COVER PLATES ST ST
CATV CABLING ST ST
LIGHTING & SHADE CONTROL INTERFACE EC EC
REFER TO AV DETAIL SHEETS FOR ADDITIONAL SCOPE DELINEATION AND INFORMATION
MO
SE
LE
YA
RC
HIT
EC
TS
.CO
M
PROJECT NO:DATE:
320
0 N
OR
FO
LK
ST
RE
ET
, R
ICH
MO
ND
, V
A 2
323
0
PH
ON
E (
80
4)
79
4-7
555
F
AX
(8
04
) 3
55
-569
0
A
B
C
D
E
1 2 4 53 6 7 8 9 10
F
G
H
I
J
3/3
1/2
02
0 4
:08:1
2 P
M
AUDIOVISUAL LEGEND
CIT
Y O
F V
IRG
INIA
BE
AC
H
BU
ILD
ING
11
RE
NO
VA
TIO
N
Pro
ject
Ad
dre
ss
TA0.0.0
PW
CN
-18-
0156
CIP
-3-1
74
548507MARCH 31, 2020
NUMBER NAME
TA0.0.0 AUDIOVISUAL LEGEND
TA1.1 AUDIOVISUAL OVERALL PLAN LOWER
TA1.2 AUDIOVISUAL OVERALL PLAN FIRST FLOOR
TA1.3 AUDIOVISUAL OVERALL PLAN SECOND FLOOR
TA2.1 AUDIOVISUAL OVERALL RCP LOWER
TA2.2 AUDIOVISUAL OVERALL RCP FIRST FLOOR
TA2.3 AUDIOVISUAL OVERALL RCP SECOND FLOOR
TA3.1 LOWER LEVEL ENLARGED PLANS
REVISIONS
DATE DESCRIPTION
REF.
FEC
TA3.1
1
Room
051
PRINT SHOP
007
Room
50
Room
51
STAFF TOILET
020
CIRCULATION
002
STAIR
006OPEN OFFICE
003
OPEN OFFICE
024
OPEN OFFICE
030
CONFERENCE ROOM
047
MECHANICAL ROOM
044
STAIR
001
PHONE BOOTH
038
BOOT WASH
043
CONFERENCE ROOM
048
WORKROOM
023
IT SERVER
045
1:1 CONFERENCE
029
STAFF TOILET
021
ELECTRICAL
046
HOUSEKEEPING
041
LACTATION
042
ASSET RECOVERY
005
PLUMBING ACCESS
252
ELEVATOR
049
ELEV EQUIP
022
TIER 1 CALL CENTER
011
NOC
015
ITAC
016
INFO SEC
017
CA SUPERVISOR
013
CONVERGENT ARCHITECTURE LAB
014
SYSTEMS ENGINEER I
004
PRINT ROOM - STAFF
008
ASSET RECOVERY - STAFF
009
SOLUTIONS ENGINEERSUPERVISOR
010
OPS MANAGER
012
INFO SEC MGR
018
DIVISION MANAGER
025
INSPECTION COORDINATOR II
026
CONSTRUCTION BUREAU MANAGER
027
STORAGE
028
SURVEY TECHNICIAN
031
CITY SURVEYOR
033
STORAGE
035
CREW ROOM
036
STORAGE
037
BREAK ROOM
019
1:1 CONFERENCE
032
PHONE BOOTH
039PHONE BOOTH
040TA3.1
5
NOTE: DEMOUNTABLE PARTITIONS AND DOORS SHOWN DASHED FOR INFORMATION AND COORDINATION PURPOSES ONLY, NIC. REFER TO THE FURNITURE DRAWINGS AND THE PROJECT MANUAL PREAMBLE-ALTERNATES AND UNIT PRICING FOR ADDITIONAL INFORMATION
MO
SE
LE
YA
RC
HIT
EC
TS
.CO
M
PROJECT NO:DATE:
320
0 N
OR
FO
LK
ST
RE
ET
, R
ICH
MO
ND
, V
A 2
323
0
PH
ON
E (
80
4)
79
4-7
555
F
AX
(8
04
) 3
55
-569
0
A
B
C
D
E
1 2 4 53 6 7 8 9 10
F
G
H
I
J
3/3
1/2
02
0 4
:08:1
3 P
M
AUDIOVISUAL OVERALL
PLAN LOWER
CIT
Y O
F V
IRG
INIA
BE
AC
H
BU
ILD
ING
11
RE
NO
VA
TIO
N
Pro
ject
Ad
dre
ss
TA1.1
PW
CN
-18-
0156
CIP
-3-1
74
548507MARCH 31, 2020
1/8" = 1'-0"1
AUDIOVISUAL OVERALL PLAN LOWER
REVISIONS
DATE DESCRIPTION
REF.REF.
DN
DN
STAIR
132
STAIR
113
OPEN OFFICE
121
CADD ROOM
140
OPEN OFFICE
101
ENGINEER IV
118
ELEVATOR
161
WOMEN
129
OPEN OFFICE
157
ENGINEER V
105
CONFERENCE ROOM
137
STAFF TOILET
135
Room
000
CORRIDOR
160
CONFERENCE ROOM
114
OPEN OFFICE
106
SHARED WORK AREA
112
STAIR
149
OPEN OFFICE
143
BREAKROOM
138CONFERENCE ROOM
139
OPEN OFFICE
153
STAFF TOILET
133
MEN
130
LACTATION
127HOUSEKEEPING
128
PLUMBING ACCESS
259
PLUMBING ACCESS
134
PHONE BOOTH
136
SYSTEMS ANALYST III
144
SYSTEMS ANALYST III
145
GIS COORDINATOR
146
CADD SUPERVISOR
142
ENGINEERING TECHNICIAN III
141
1:1 CONFERENCE
147
STORAGE
131
QA/QC MANAGER
107
1:1 CONFERENCE
111
ENGINEER V
152
STORAGE
151
ENGINEER IV
155
ENGINEER IV
156
ENGINEER V
154
PROJECT MANAGER SUPERVISOR
124
PROJECT MANAGER SUPERVISOR
125
TECHNICAL SERVICES MANAGER
126
STORMWATER ENGINEERINGCENTER ADMINISTRATOR
120
ENGINEER V
119
ENGINEER IV
117
ENGINEER IV
116
OPEN OFFICE
110
1:1 CONFERENCE
122
ENGINEER IV
108
HUDDLE AREA
115
OPEN OFFICE
104
ADMINISTRATIVE SPECIALIST I
103
STORAGE
102
LOBBY
100 ENGINEER IV
158
ENGINEER IV
159
ELECTRICAL
109
IT ROOM
123
HUDDLE AREA
148ELECTRICAL
150
NOTE: DEMOUNTABLE PARTITIONS AND DOORS SHOWN DASHED FOR INFORMATION AND COORDINATION PURPOSES ONLY, NIC. REFER TO THE FURNITURE DRAWINGS AND THE PROJECT MANUAL PREAMBLE-ALTERNATES AND UNIT PRICING FOR ADDITIONAL INFORMATION
MO
SE
LE
YA
RC
HIT
EC
TS
.CO
M
PROJECT NO:DATE:
320
0 N
OR
FO
LK
ST
RE
ET
, R
ICH
MO
ND
, V
A 2
323
0
PH
ON
E (
80
4)
79
4-7
555
F
AX
(8
04
) 3
55
-569
0
A
B
C
D
E
1 2 4 53 6 7 8 9 10
F
G
H
I
J
3/3
1/2
02
0 4
:08:1
5 P
M
AUDIOVISUAL OVERALL
PLAN FIRST FLOOR
CIT
Y O
F V
IRG
INIA
BE
AC
H
BU
ILD
ING
11
RE
NO
VA
TIO
N
Pro
ject
Ad
dre
ss
TA1.2
PW
CN
-18-
0156
CIP
-3-1
74
548507MARCH 31, 2020
1/8" = 1'-0"1
AUDIOVISUAL OVERALL PLAN FIRST FLOOR
REVISIONS
DATE DESCRIPTION
OPEN OFFICE
205
OPEN OFFICE
220
OPEN OFFICE
213
OPEN OFFICE
209
SHARED WORK AREA
234
CORRIDOR
201
STAIR
254
ELEVATOR
235
STAIR
211
MEN
202
MECH
219
CONFERENCE ROOM
208
CITY ENGINEER
223
CONFERENCE ROOM
231
CONFERENCE ROOM
221
CONFERENCE ROOM
225
WOMEN
203
ACCESS
204
LACTATION ROOM
206
ENGINEER V
207
CONTRACT SUPERVISOR
210
ENGINEER IV
214
ENGINEER V
215
ADMIN ASST
217
FILES
216
1:1 CONFERENCE
222
ADMINISTRATIVE SERVICESMANAGER III
224
OPERATIONS SUPPORTADMINISTRATOR
226
DIRECTOR
227
EXECUTIVE ASSISTANT
228
MEDIA & COMMUNICATIONS
229
IT POSITION
230
FILE ROOM
212
ELECTRICAL
218
IT ROOM
232
STORAGE
233
NOTE: DEMOUNTABLE PARTITIONS AND DOORS SHOWN DASHED FOR INFORMATION AND COORDINATION PURPOSES ONLY, NIC. REFER TO THE FURNITURE DRAWINGS AND THE PROJECT MANUAL PREAMBLE-ALTERNATES AND UNIT PRICING FOR ADDITIONAL INFORMATION
MO
SE
LE
YA
RC
HIT
EC
TS
.CO
M
PROJECT NO:DATE:
320
0 N
OR
FO
LK
ST
RE
ET
, R
ICH
MO
ND
, V
A 2
323
0
PH
ON
E (
80
4)
79
4-7
555
F
AX
(8
04
) 3
55
-569
0
A
B
C
D
E
1 2 4 53 6 7 8 9 10
F
G
H
I
J
3/3
1/2
02
0 4
:08:1
7 P
M
AUDIOVISUAL OVERALL
PLAN SECOND FLOOR
CIT
Y O
F V
IRG
INIA
BE
AC
H
BU
ILD
ING
11
RE
NO
VA
TIO
N
Pro
ject
Ad
dre
ss
TA1.3
PW
CN
-18-
0156
CIP
-3-1
74
548507MARCH 31, 2020
1/8" = 1'-0"1
AUDIOVISUAL OVERALL PLAN SECOND FLOORREVISIONS
DATE DESCRIPTION
Room
051
PRINT SHOP
007
Room
50
Room
51
?
?
?
?
CIRCULATION
002
?
?
STAIR
006OPEN OFFICE
003
CONFERENCE ROOM
047
MECHANICAL ROOM
044
STAIR
001
STAIR
006
PHONE BOOTH
038
BOOT WASH
043
?
?
CONFERENCE ROOM
048
IT SERVER
045
STAFF TOILET
021
ELECTRICAL
046
HOUSEKEEPING
041
LACTATION
042
ASSET RECOVERY
005
?
?
?
?
ELEVATOR
049
ELEV EQUIP
022
TIER 1 CALL CENTER
011
NOC
015
ITAC
016
INFO SEC
017
NOTE: DEMOUNTABLE PARTITIONS AND DOORS SHOWN DASHED FOR INFORMATION AND COORDINATION PURPOSES ONLY, NIC. REFER TO THE FURNITURE DRAWINGS AND THE PROJECT MANUAL PREAMBLE-ALTERNATES AND UNIT PRICING FOR ADDITIONAL INFORMATION
MO
SE
LE
YA
RC
HIT
EC
TS
.CO
M
PROJECT NO:DATE:
320
0 N
OR
FO
LK
ST
RE
ET
, R
ICH
MO
ND
, V
A 2
323
0
PH
ON
E (
80
4)
79
4-7
555
F
AX
(8
04
) 3
55
-569
0
A
B
C
D
E
1 2 4 53 6 7 8 9 10
F
G
H
I
J
3/3
1/2
02
0 4
:08:1
8 P
M
AUDIOVISUAL OVERALL
RCP LOWER
CIT
Y O
F V
IRG
INIA
BE
AC
H
BU
ILD
ING
11
RE
NO
VA
TIO
N
Pro
ject
Ad
dre
ss
TA2.1
PW
CN
-18-
0156
CIP
-3-1
74
548507MARCH 31, 2020
1/8" = 1'-0"1
AUDIOVISUAL OVERALL RCP LOWER
REVISIONS
DATE DESCRIPTION
STAIR
132
STAIR
113
ELEVATOR
161
WOMEN
129
CONFERENCE ROOM
137
STAFF TOILET
135
Room
000
CORRIDOR
160
CONFERENCE ROOM
114
STAIR
149
CONFERENCE ROOM
139
STAFF TOILET
133
MEN
130
LACTATION
127
HOUSEKEEPING
128
PLUMBING ACCESS
259
PLUMBING ACCESS
134
PHONE BOOTH
136
NOTE: DEMOUNTABLE PARTITIONS AND DOORS SHOWN DASHED FOR INFORMATION AND COORDINATION PURPOSES ONLY, NIC. REFER TO THE FURNITURE DRAWINGS AND THE PROJECT MANUAL PREAMBLE-ALTERNATES AND UNIT PRICING FOR ADDITIONAL INFORMATION
MO
SE
LE
YA
RC
HIT
EC
TS
.CO
M
PROJECT NO:DATE:
320
0 N
OR
FO
LK
ST
RE
ET
, R
ICH
MO
ND
, V
A 2
323
0
PH
ON
E (
80
4)
79
4-7
555
F
AX
(8
04
) 3
55
-569
0
A
B
C
D
E
1 2 4 53 6 7 8 9 10
F
G
H
I
J
3/3
1/2
02
0 4
:08:2
0 P
M
AUDIOVISUAL OVERALL
RCP FIRST FLOOR
CIT
Y O
F V
IRG
INIA
BE
AC
H
BU
ILD
ING
11
RE
NO
VA
TIO
N
Pro
ject
Ad
dre
ss
TA2.2
PW
CN
-18-
0156
CIP
-3-1
74
548507MARCH 31, 2020
1/8" = 1'-0"1
AUDIOVISUAL OVERALL RCP FIRST FLOOR
REVISIONS
DATE DESCRIPTION
OPEN OFFICE
205
OPEN OFFICE
209
SHARED WORK AREA
234
STAIR
254
ELEVATOR
235
STAIR
211
MEN
202
MECH
219
?
?
CONFERENCE ROOM
208
CONFERENCE ROOM
231
CONFERENCE ROOM
221
WOMEN
203
ACCESS
204
LACTATION ROOM
206
NOTE: DEMOUNTABLE PARTITIONS AND DOORS SHOWN DASHED FOR INFORMATION AND COORDINATION PURPOSES ONLY, NIC. REFER TO THE FURNITURE DRAWINGS AND THE PROJECT MANUAL PREAMBLE-ALTERNATES AND UNIT PRICING FOR ADDITIONAL INFORMATION
MO
SE
LE
YA
RC
HIT
EC
TS
.CO
M
PROJECT NO:DATE:
320
0 N
OR
FO
LK
ST
RE
ET
, R
ICH
MO
ND
, V
A 2
323
0
PH
ON
E (
80
4)
79
4-7
555
F
AX
(8
04
) 3
55
-569
0
A
B
C
D
E
1 2 4 53 6 7 8 9 10
F
G
H
I
J
3/3
1/2
02
0 4
:08:2
1 P
M
AUDIOVISUAL OVERALL
RCP SECOND FLOOR
CIT
Y O
F V
IRG
INIA
BE
AC
H
BU
ILD
ING
11
RE
NO
VA
TIO
N
Pro
ject
Ad
dre
ss
TA2.3
PW
CN
-18-
0156
CIP
-3-1
74
548507MARCH 31, 2020
1/8" = 1'-0"1
AUDIOVISUAL OVERALL RCP SECOND FLOOR
REVISIONS
DATE DESCRIPTION
NOC
015
TA3.1 2
TA3.1
3
TA3.1
4
102
110
131
OPS MANAGER
012
CONVERGENT ARCHITECTURE LAB
014
CA SUPERVISOR
013
TIER 1 CALL CENTER
011
112
111
142
111
3' -
6"
136
1' -
6"
102
131
5' -
6"
3' -
6"7
' - 1
0 1
7/3
2"
112
136
1' -
6"
IT SERVER
045 146
MO
SE
LE
YA
RC
HIT
EC
TS
.CO
M
PROJECT NO:DATE:
320
0 N
OR
FO
LK
ST
RE
ET
, R
ICH
MO
ND
, V
A 2
323
0
PH
ON
E (
80
4)
79
4-7
555
F
AX
(8
04
) 3
55
-569
0
A
B
C
D
E
1 2 4 53 6 7 8 9 10
F
G
H
I
J
3/3
1/2
02
0 4
:08:2
3 P
M
LOWER LEVEL
ENLARGED PLANS
CIT
Y O
F V
IRG
INIA
BE
AC
H
BU
ILD
ING
11
RE
NO
VA
TIO
N
Pro
ject
Ad
dre
ss
TA3.1
PW
CN
-18-
0156
CIP
-3-1
74
548507MARCH 31, 2020
1/4" = 1'-0"1
NOC 015, TIER 1 CALL CENTER 011, CONVERGENT ARCHITECTURE LAB 014 ENLARGED FACILITY PLAN
AUDIOVISUAL FACILITY KEYNOTE LEGEND
NUMBER DESCRIPTION
102 65" FLAT PANEL DISPLAY WITH DISPLAY BACK BOX
110 DUAL ARM FULL SWING DISPLAY MOUNT KIT
111 VIDEO WALL DISPLAY, 55", 2X2
112 VIDEO WALL DISPLAY, 55", 6X2
131 WALL MOUNTED PTZ CAMERA
136 AV WALL PLATE
142 AV FLOOR BOX
146 AV EQUIPMENT RACK - FLOOR STANDING, FULL SIZE
1/4" = 1'-0"2
NOC 015 ELEVATION1/4" = 1'-0"
3CONVERGENT ARCHITECTURE LAB 014 ELEVATION
1/4" = 1'-0"4
TEIR 1 CALL CENTER 011 ELEVATION
REVISIONS
DATE DESCRIPTION
1/4" = 1'-0"5
IT SERVER F045 FACILITY ENLARGED PLAN