bsc6810v200r011 global and equipment data configuartion

Upload: eric-frimpong-gyamfi

Post on 02-Jun-2018

217 views

Category:

Documents


0 download

TRANSCRIPT

  • 8/10/2019 BSC6810V200R011 Global and Equipment Data Configuartion

    1/67

    HUAWEI TECHNOLOGIES CO., LTD. All rights reserved

    www.huawei.com

    Internal

    Global and Equipment

    Data ConfigurationBased on MML Commands

    BSC6810V200R011

  • 8/10/2019 BSC6810V200R011 Global and Equipment Data Configuartion

    2/67

    HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 2

    Upon completion this course, you will be able to:

    Master the procedure and methods of data

    configuration of BSC6810

    Master global data configuration

  • 8/10/2019 BSC6810V200R011 Global and Equipment Data Configuartion

    3/67

    HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 3

    RNC System Description

    RNC Initial Configuration Guide

  • 8/10/2019 BSC6810V200R011 Global and Equipment Data Configuartion

    4/67

    HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 4

    Chapter 1 Data Configuration Overview

    Chapter 2 Global Data Configuration

    Chapter 3 Equipment Data Configuration

  • 8/10/2019 BSC6810V200R011 Global and Equipment Data Configuartion

    5/67

    HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 5

    Local Maintenance Terminal ( MML Client )

    The local maintenance terminal is an item of the LMT software.

    The local maintenance terminal adopts the GUI and the MML

    (Man Machine Language) to operate and maintain the system.

    Note: Data configuration is realized by the MML commands.

  • 8/10/2019 BSC6810V200R011 Global and Equipment Data Configuartion

    6/67

    HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 6

    Application Scenarios of MML Deployment

    During the deployment, engineers should configure BSC6810 data

    configuration script according to the negotiation data for stand alone

    RNC during initial setupand run the script by MML commands in

    batches.

    Modify data in batch mode

    When the RNP or RNO engineers need to modify mass incumbent

    BSC6810 configuration data, they can modify BSC6810 configuration

    data through running MML command script in batch mode.

    Modify a few configuration data

    When a few configuration data need to be modified, every single MML

    command can be run to execute the function.

  • 8/10/2019 BSC6810V200R011 Global and Equipment Data Configuartion

    7/67HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 7

    Open LMT

    Choose Start > All Programs >

    Huawei Local Maintenance

    Terminal > Local Maintenance

    Terminal.

    On BSC6810 Local

    Maintenance Terminal, choose

    System > Execute MML Client.

    On BSC6810 Local

    Maintenance Terminal, click theicon to start the Local

    Maintenance Terminal.

    Use one of the following 3 methods to start the HUAWEI LMT

    : Consider the different between Local and EMS?

  • 8/10/2019 BSC6810V200R011 Global and Equipment Data Configuartion

    8/67

    HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 8

    InterfaceMenu bar

    Tool bar

    Command

    window

    Output window

    Status bar

    Navigation tree

  • 8/10/2019 BSC6810V200R011 Global and Equipment Data Configuartion

    9/67

    HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 9

    Data Configuration Methods

    1.Offline data configuration

    2.Online data configuration

    .dat filesBoards

    of FAM

    BAM

    Configuration

    MML commandsDatabase

    Loading

    by resetting

    FormattingLMT

    ..dat files

    Boards of

    FAM

    BAM

    Configuration

    MML commandsDatabase

    Loadingdirectly

    FormattingLMT

  • 8/10/2019 BSC6810V200R011 Global and Equipment Data Configuartion

    10/67

    HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 10

    Offline Data Configuration

    Parameters input

    Help information

    of command

    Command

    input

    Command display

    Save = F9

  • 8/10/2019 BSC6810V200R011 Global and Equipment Data Configuartion

    11/67

    HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 11

    Offline Data Configuration When the system is offline, and F9 are used to save the input

    command.

    When you click or

    press F9 the first time

    after you enter the

    command, the system

    displays the save dialog

    box. If you want to save

    the command, you must

    specify the mandatory

    parameters.

    The default path for saving input commands is: LMT installation directory

    \ client \ output \ BSC6810 \ version number \ batch \.

  • 8/10/2019 BSC6810V200R011 Global and Equipment Data Configuartion

    12/67

    HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 12

    Online Data Configuration

    The commandexecutes

    successful

  • 8/10/2019 BSC6810V200R011 Global and Equipment Data Configuartion

    13/67

    HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 13

    Running MML Commands in Batches

    Running MML commands in batches refers to running multiple MML commands at a time. The

    pre-edited batch file is run on the Local Maintenance Terminal so that you do not need to

    manually run every MML command.

    The batch file is a plain text file. It contains a group of command scripts for a special task. The

    system automatically runs the commands in sequence.

    You can run MML commands in batches through two methods: immediate batch command and

    timing batch command.

    Immediate batch command refers to running the batch file immediately.

    Timing batch command: The operator set in advance the date and time

    when the batch file is run. The system automatically run the batch file on

    the date and at the time.

  • 8/10/2019 BSC6810V200R011 Global and Equipment Data Configuartion

    14/67

    HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 14

    Immediate Batch Command - Start

  • 8/10/2019 BSC6810V200R011 Global and Equipment Data Configuartion

    15/67

    HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 15

    Immediate Batch Command

    Click . A Set dialog box is displayed.

  • 8/10/2019 BSC6810V200R011 Global and Equipment Data Configuartion

    16/67

    HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 16

    Timing Batch Command

  • 8/10/2019 BSC6810V200R011 Global and Equipment Data Configuartion

    17/67

    HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 17

    Timing Batch Command

    Select the Timing Batch Command tab page.

    Click . A Add Batch Task dialog box is displayed.

    Click . The Open dialog box is displayed. Select the pre-

    edited batch file.

    Click to refresh Add Batch Task dialog box .

    Set all the parameters in Add Batch Task dialog box, and

    then click to refresh Timing Batch Command tab

    page.i Caution: Do not close the MML Batch dialog box. If you closeit, the batch task will be deleted.

  • 8/10/2019 BSC6810V200R011 Global and Equipment Data Configuartion

    18/67

    HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 18

    Data Configuration Overview

    Configuration Command Action Description

    Action Meaning

    ADD Add an object

    SET Set an object

    LST Query BAM database configuration information

    DSP Query FAM object state or BAM running state

    MOD Modify an object

    RMV Remove an object

    ACT Activate an object

    DEA Deactivate an object

    RST Reset an object

    What is different between ADD and SET ?

    What is different between LST and DSP ?

  • 8/10/2019 BSC6810V200R011 Global and Equipment Data Configuartion

    19/67

    HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 19

    Data Configuration Overview

    Data Configuration Control

    BSC6810 controls whether LMT or M2000 has the permission

    to configure the data at a time to avoid the data conflict

    Check the status of CMC (REQ CMCTRL)

    Procedure of obtaining CMC in different cases

    Lock CMC

    If Then

    M2000 communicates with BSC6810 normally

    Use the REQ CMCTRLcommand to request the CMC.

    If M2000 approves, LMT will get it

    M2000 cannot communicate with BSC6810 or

    BSC6810 is not equipped with M2000

    Use the FOC CMCTRLcommand to obtain the CMC

    forcibly

  • 8/10/2019 BSC6810V200R011 Global and Equipment Data Configuartion

    20/67

    HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 20

    Data Configuration Overview

    Configuration procedures of initial setup RNC

    Global dataconfiguration

    Equipment dataconfiguration

    Interface dataconfiguration

    Cell data configuration

    Start

    End

    BSC6810

    BSC6810

    NodeB

    NodeB

    NodeB

    MSC Server

    MGW

    SGSN

    UE UTRAN CNUu Iu

    Iu-CS

    Iu-PS

    Iur

    Iub

    Iub

  • 8/10/2019 BSC6810V200R011 Global and Equipment Data Configuartion

    21/67

    HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 21

    Chapter 1 Data Configuration Overview

    Chapter 2 Global Data Configuration

    Chapter 3 Equipment Data Configuration

  • 8/10/2019 BSC6810V200R011 Global and Equipment Data Configuartion

    22/67

    HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 22

    Global Data Configuration Procedure

    End

    Start

    Adding RNC basic data

    Adding original signaling

    point data

    Activate license file

    Adding RNC global location

    Adding local M3UA entity

    Global parameter is used to identify the

    RNC in a network.

    This is the first step of RNC initial

    configuration, use SET OFFLINE

    command switch RNC all

    subrack to offline mode.

    During the RNC initial configuration,

    global data include several necessary

    steps as shown in right procedure flow.

  • 8/10/2019 BSC6810V200R011 Global and Equipment Data Configuartion

    23/67

    HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 23

    ConfigureRNC Basic Data Information

    ADD RNCBASIC :offline mandatory

    SET OPERATORSHARINGMODE:optional

    ADD CNOPERATOR: offline mandatory

    ADD CNOPERGROUP :mandatory

    SET OPERATORCFGPARA:optional

    SET SUBNET : optional

    SET SCTPSVRPORT: optional

    End

    Start

    Adding RNC basic data

    Adding original signaling

    point data

    Activate license file

    Adding RNC global location

    Adding local M3UA entity

  • 8/10/2019 BSC6810V200R011 Global and Equipment Data Configuartion

    24/67

    HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 24

    The command is an offline command which can only be executed in offline mode.

    RNC id range is 0-4096 and used to uniquely identifying an RNC in same

    operator network.

    ATM address: use to distinguish equipment in ATM transmission network.

    ConfigureRNC Basic Data Information

    Paramters of ADD RNCBASIC command

  • 8/10/2019 BSC6810V200R011 Global and Equipment Data Configuartion

    25/67

    HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 25

    Paramters of SET OPERATORSHARINGMODEcommand

    RAN Sharing Support: Multiple operators to share a set

    of RAN equipment that covers the same area.

    MOCN: Multi-operator share frequency resource mode.

    Intra RAT Inter Plmn Ho Allowed: Intra Plmn handover.

    Inter RAT Inter Plmn Ho Allowed: Inter Plmn handover.

    ConfigureRNC Basic Data Information

    RNC1

    Operator 2

    RNC2

    RNC3

    Operator 1

  • 8/10/2019 BSC6810V200R011 Global and Equipment Data Configuartion

    26/67

    HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 26

    Configure RNC Basic Data Information

    Paramters of ADD CNOPERATOR command

    Cn Operator Name: Value range: String long 1 ~ 31

    Mobile country code: MCC Value range: 000 to 999

    Mobile network code: MNC Value range: 00 to 99 or 000 to 999

    Cn Operator index: Value range: 5-31

  • 8/10/2019 BSC6810V200R011 Global and Equipment Data Configuartion

    27/67

    HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 27

    PRIM:Primary operator, determines functions to be supported the entire RAN system

    and allocates licenses to secondary operators. The primary operator permits registration

    and access the UE.

    SEC:Secondary operator, functions to be supported the entire RAN system and the

    license of the secondary operators are controlled by primary operator. Secondary

    operator permit access UE.

    OUTER:Outer operator, In mobility management, UEs need to be hand over from the

    operator of the source RNC to the operator of the target RNC. If the operator is not the

    primary operator and secondary operator of the source RNC, you need to specify the

    operator as an outer operator so that the operator support the mobility management.

    COMM:operator that supports non-support UEs, The PLMN ID indicated in the system

    broadcast information as defined for conversational networks, which non-support UEs

    understand as the serving opertaor.

    Configure RNC Basic Data Information

  • 8/10/2019 BSC6810V200R011 Global and Equipment Data Configuartion

    28/67

  • 8/10/2019 BSC6810V200R011 Global and Equipment Data Configuartion

    29/67

    HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 29

    Configure RNC Basic Data Information

    Paramters of ADD CNOPERATOR command

    In one operator group, can be configure 1-4 real operator index

    In one operator group, can choose to configure one common operator index.

    CNOPERATORGROUP is to facilitate maintenance and management.

  • 8/10/2019 BSC6810V200R011 Global and Equipment Data Configuartion

    30/67

    HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 30

    Configure RNC Basic Data Information

    Paramters of SET OPERATORCFGPARA command

    If the RNC system support IU-FLEX and MOCNthis command use to configure

    NRI parameter.NRI (network recourse identifier) is part of the temporary indentity TMSI (CS

    domain) or P-TMSI (PS domain), which is assigned by the serving CN node to the

    UE.

  • 8/10/2019 BSC6810V200R011 Global and Equipment Data Configuartion

    31/67

    HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 31

    Set RNC Internal Subnet No.

    WRBS

    SCU

    80.x.x.x

    Configure RNC Basic Data Information

    WRBS

    BAM

    External

    BAM

    Internal

  • 8/10/2019 BSC6810V200R011 Global and Equipment Data Configuartion

    32/67

    HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 32

    Parameter of SET SCTPSRVPORT command.

    Configure RNC Basic Data Information

    The default parameter:

    NBAP port No. is 58085.

    M3UA port No. is 2910.

  • 8/10/2019 BSC6810V200R011 Global and Equipment Data Configuartion

    33/67

    HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 33

    Configure Original Signaling Point Data

    ADD OPC: offline mandatory

    End

    Start

    Adding RNC basic data

    Adding original signaling

    point data

    Activate license file

    Adding RNC global location

    Adding local M3UA entity

  • 8/10/2019 BSC6810V200R011 Global and Equipment Data Configuartion

    34/67

    HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 34

    Parameter of ADD OPC command

    Configure Original Signaling Point Data

    OSP name: 1~31 characters.

    Network ID:

    INT: international network.

    INTB: international reserved.

    NAT: national network.

    NATB: national reserved.

  • 8/10/2019 BSC6810V200R011 Global and Equipment Data Configuartion

    35/67

    HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 35

    Configure Original Signaling Point Data

    OSP code bits: Value range: BIT14, BIT16, BIT24.

    OSP code: negation data. Value range:

    H'1~H'3FFF(1~16383),H'1~H'FFFF(1~65535), H'1~H'FFFFFF(1~16777215).

    or BIT24

    BIT16 osp code without restart switch.

  • 8/10/2019 BSC6810V200R011 Global and Equipment Data Configuartion

    36/67

  • 8/10/2019 BSC6810V200R011 Global and Equipment Data Configuartion

    37/67

    HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 37

    Activate License File

    Activate License File

    i Notice: The license file located in\BAM\FTP\LICENSE

  • 8/10/2019 BSC6810V200R011 Global and Equipment Data Configuartion

    38/67

    HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 38

    Configure Global Location Data

    ADD LAC:mandatory

    ADD RAC:mandatory

    ADD SAC: mandatory

    ADD URA:mandatory

    ADD CZ:optional

    End

    Start

    Adding RNC basic data

    Adding original signaling

    point data

    Activate license file

    Adding RNC global location

    Adding local M3UA entity

  • 8/10/2019 BSC6810V200R011 Global and Equipment Data Configuartion

    39/67

    HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 39

    ADD LAC: Add location area code

    ADD RAC: Add route area code

    ADD SAC: Add service area code

    ADD URA: Add UTRAN Registration Area

    PLMN: Public Land Mobile Network

    Configure Global Location Data

    LAC1

    RAC1

    RAC2

    SAC1 SAC2 LAC2

    PLMN

  • 8/10/2019 BSC6810V200R011 Global and Equipment Data Configuartion

    40/67

    HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 40

    UE States

    CELL_DCH CELL_FACH

    CELL_PCHURA_PCH

    IDLE

    DEAD - Scanning networks (PLMN)- Camp on cell

    - Monitor paging channel- cell re-selection

    - Dedicated Channel- Radio bearers Transmission Services

    - upper layer Signalingtrigger (CN)

    - Reduce actionDRXand save power

    RRC con nect ion

    Configure Global Location Data

  • 8/10/2019 BSC6810V200R011 Global and Equipment Data Configuartion

    41/67

    HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 41

    Parameter of ADD LAC command

    Configure Global Location Data

    LAI (location area identity)=MCC+MNC+LACPLMN value range should without intersection between LAC and RAC

  • 8/10/2019 BSC6810V200R011 Global and Equipment Data Configuartion

    42/67

    HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 42

    Parameter of ADD RAC command

    Configure Global Location Data

    RAI (Route area identity) =MCC+MNC+LAC+RAC

  • 8/10/2019 BSC6810V200R011 Global and Equipment Data Configuartion

    43/67

    HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 43

    Parameter of ADD SAC command

    Configure Global Location Data

    SAI (Source area identity) =MCC+MNC+LAC+SAC

  • 8/10/2019 BSC6810V200R011 Global and Equipment Data Configuartion

    44/67

    HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 44

    Parameter of UTRAN Registration Area command

    Configure Global Location Data

    Parameter of CZ command

  • 8/10/2019 BSC6810V200R011 Global and Equipment Data Configuartion

    45/67

    HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 45

    Configure Local M3UA Entity

    End

    Start

    Adding RNC basic data

    Adding original signaling

    point data

    Activate license file

    Adding RNC global location

    Adding local M3UA entityADD M3LE: IP network mandatory

    This command only use for IU interface IP network.

    The prerequisite is OPC configured.

    This command and IU interface IP configuration,

    the detail information please see

  • 8/10/2019 BSC6810V200R011 Global and Equipment Data Configuartion

    46/67

    HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 46

    Chapter 1 Data Configuration Overview

    Chapter 2 Global Data Configuration

    Chapter 3 Equipment Data Configuration

    E i D C fi i

  • 8/10/2019 BSC6810V200R011 Global and Equipment Data Configuartion

    47/67

    HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 47

    Equipment Data Configuration

    Equipment data configuration is used to

    identify the subracks, boards and clock

    information of RNC.

    This is the second configuration step of

    RNC initial configuration.

    During the RNC initial configuration,

    equipment data include several necessary

    steps as shown in the right procedure flow.

    Adding the IP Address of the EMS Server

    End

    Start

    Setting RNC

    Equipment Description

    Adding Basic Data of the RSS

    Adding Basic Data of the RBS

    Adding an EMU

    Configuring RNC Clock Data

    Setting RNC Time

    S i RNC E i D i i

  • 8/10/2019 BSC6810V200R011 Global and Equipment Data Configuartion

    48/67

    HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 48

    Setting RNC Equipment Description

    SET SYS: mandatory

    Adding the IP Address of the EMS Server

    End

    Start

    Setting RNCEquipment Description

    Adding Basic Data of the RSS

    Adding Basic Data of the RBS

    Adding an EMU

    Configuring RNC Clock Data

    Setting RNC Time

    S tti RNC E i t D i ti

  • 8/10/2019 BSC6810V200R011 Global and Equipment Data Configuartion

    49/67

    HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 49

    Parameter of SET SYS command

    The RNC equipment description is stored only in the BAM database and is not sent to the host.

    The actual description of each parameter should fill according to the requirement of customer

    Setting RNC Equipment Description

    Addi B i D t f th RSS

  • 8/10/2019 BSC6810V200R011 Global and Equipment Data Configuartion

    50/67

    HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 50

    Adding Basic Data of the RSS

    MOD SUBRACK: mandatory

    SET CLKTYPE: mandatory

    ADD BRD: mandatory

    SET MSP: optional

    Adding the IP Address of the EMS Server

    End

    Start

    Setting RNCEquipment Description

    Adding Basic Data of the RSS

    Adding Basic Data of the RBS

    Adding an EMU

    Configuring RNC Clock Data

    Setting RNC Time

    Addi B i D t f th RSS

  • 8/10/2019 BSC6810V200R011 Global and Equipment Data Configuartion

    51/67

    HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 51

    Parameter of MOD SUBRACK command

    Adding Basic Data of the RSS

    Parameter of SET CLKTYPE command

    Addi B i D t f th RSS

  • 8/10/2019 BSC6810V200R011 Global and Equipment Data Configuartion

    52/67

    HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 52

    Parameter of ADD BRD command

    Adding Basic Data of the RSS

    Back up: This parameter indicates whether the board is backup or not.

    Addi B i D t f th RSS

  • 8/10/2019 BSC6810V200R011 Global and Equipment Data Configuartion

    53/67

    HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 53

    Adding Basic Data of the RSS

    Parameter of ADD BRD command

    UCP: UMTS RNC Control plane Process=SPU

    RUCP: Resource Management and UMTS RNC Control plane Process= MPU

    UUP: UMTS RNC User plane Process = DPU

    Adding Basic Data of the RBS

  • 8/10/2019 BSC6810V200R011 Global and Equipment Data Configuartion

    54/67

    HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 54

    Adding Basic Data of the RBS

    ADD SUBRACK: mandatory

    ADD BRD: mandatory

    SET MSP: optional

    Adding the IP Address of the EMS Server

    End

    Start

    Setting RNCEquipment Description

    Adding Basic Data of the RSS

    Adding Basic Data of the RBS

    Adding an EMU

    Configuring RNC Clock Data

    Setting RNC Time

    Adding Basic Data of the RBS

  • 8/10/2019 BSC6810V200R011 Global and Equipment Data Configuartion

    55/67

    HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 55

    Parameter of ADD SUBRACK

    Adding Basic Data of the RBS

    Adding an EMU

  • 8/10/2019 BSC6810V200R011 Global and Equipment Data Configuartion

    56/67

    HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 56

    Adding an EMU

    ADD EMU: Optional

    Adding the IP Address of the EMS Server

    End

    Start

    Setting RNCEquipment Description

    Adding Basic Data of the RSS

    Adding Basic Data of the RBS

    Adding an EMU

    Configuring RNC Clock Data

    Setting RNC Time

  • 8/10/2019 BSC6810V200R011 Global and Equipment Data Configuartion

    57/67

    HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 57

    Adding an EMU

    Parameter of ADD EMU

    Configuring RNC Clock Data

  • 8/10/2019 BSC6810V200R011 Global and Equipment Data Configuartion

    58/67

    HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 58

    Configuring RNC Clock Data

    SET CLK: mandatory

    ADD CLKSRC: mandatory

    SET CLKMODE: mandatory

    Adding the IP Address of the EMS Server

    End

    Start

    Setting RNCEquipment Description

    Adding Basic Data of the RSS

    Adding Basic Data of the RBS

    Adding an EMU

    Configuring RNC Clock Data

    Setting RNC Time

    Configuring RNC Clock Data

  • 8/10/2019 BSC6810V200R011 Global and Equipment Data Configuartion

    59/67

    HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 59

    Configuring RNC Clock Data

    Parameter of SET CLK command

    1. You can set the clock source of interface boards in the RSS to backplane 8 K output clock sourcewhich cannot be set for that of interface boards in the RBS.

    2. You can choose 0 to 31 as the link number when setting the clock source for the AEU and PEU.

    You can choose 0 and 1 as the link number when setting the clock source for the AOU.

    You can choose 0 to 3 as the link number when setting the clock source for the UOI.

    Configuring RNC Clock Data

  • 8/10/2019 BSC6810V200R011 Global and Equipment Data Configuartion

    60/67

    HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 60

    Configuring RNC Clock Data

    Parameter of ADD CLKSRC command

    1 (Top priority)

    2 (High priority)

    3 (Low priority)

    4 (Lower priority)

    0 (Lowest priority =Local Clock)

    LINE1-8KHZ

    LINE2-8KHZ

    Can be get from interface board or external clock source such as BITS

    provide two channels of 8 kHz clock signals that are locked

    at the interface boards and transported to the backplane.

    Is the independent clock source and input from com1 of GCUa board

    BITS1-2MHZ

    BITS2-2MHZ

    BITS1-2MBPS

    BITS2-2MBPS

    8KHZ

    Configuring RNC Clock Data

  • 8/10/2019 BSC6810V200R011 Global and Equipment Data Configuartion

    61/67

    HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 61

    Configuring RNC Clock Data

    Parameter of SET CLKMODE command

    Manual: The user specifies a clock source and inhibits it from automatically

    being handed over to other sources.

    Auto: The user is not required to specify a clock source and the system is able to

    select the clock source with the highest priority automatically.

  • 8/10/2019 BSC6810V200R011 Global and Equipment Data Configuartion

    62/67

    Configuring RNC Clock Data

  • 8/10/2019 BSC6810V200R011 Global and Equipment Data Configuartion

    63/67

    HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 63

    Configuring RNC Clock Data

    SET TZ: mandatory

    ADD SNTPSRVINFO:optional

    SET SNTPCLTPARA: optional

    Adding the IP Address of the EMS Server

    End

    Start

    Setting RNCEquipment Description

    Adding Basic Data of the RSS

    Adding Basic Data of the RBS

    Adding an EMU

    Configuring RNC Clock Data

    Setting RNC Time

  • 8/10/2019 BSC6810V200R011 Global and Equipment Data Configuartion

    64/67

    HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 64

    SNTP

    serverSNTP server

    SNTP client

    SNTP clientSNTP server

    RNC NodeBM2000

    Configuring RNC Clock Data

    RNC external network view: M2000 is the SNTP server of RNC

    RNC is the SNTP client of M2000.

    RNC internal network view: RNC is the SNTP server of NodeB

    NodeB is the SNTP Client of RNC.

    Config ring RNC Clock Data

  • 8/10/2019 BSC6810V200R011 Global and Equipment Data Configuartion

    65/67

    HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 65

    Configuring RNC Clock Data

    SNTP: Simple network time protocol.

    SNTP server IP is the IP address of M2000. Port number is 123.

    The number of the SNTP Servers cannot exceed 16.

    If multiple SNTP servers are configured, SNTP Client chooses the best

    SNTP server as the clock source according to the algorithm defined in

    the NTP protocol.

    Parameter of SET SNTPCLTPARA command

    Configuring RNC Clock Data

  • 8/10/2019 BSC6810V200R011 Global and Equipment Data Configuartion

    66/67

    HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 66

    Configuring RNC Clock Data

    ADD EMSIP: mandatory for M2000 IP.

    Detail see interface configurationAdding the IP Address of the EMS Server

    End

    Start

    Setting RNCEquipment Description

    Adding Basic Data of the RSS

    Adding Basic Data of the RBS

    Adding an EMU

    Configuring RNC Clock Data

    Setting RNC Time

  • 8/10/2019 BSC6810V200R011 Global and Equipment Data Configuartion

    67/67

    Thank You