bsc6810v200r011 global and equipment data configuartion
TRANSCRIPT
-
8/10/2019 BSC6810V200R011 Global and Equipment Data Configuartion
1/67
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved
www.huawei.com
Internal
Global and Equipment
Data ConfigurationBased on MML Commands
BSC6810V200R011
-
8/10/2019 BSC6810V200R011 Global and Equipment Data Configuartion
2/67
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 2
Upon completion this course, you will be able to:
Master the procedure and methods of data
configuration of BSC6810
Master global data configuration
-
8/10/2019 BSC6810V200R011 Global and Equipment Data Configuartion
3/67
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 3
RNC System Description
RNC Initial Configuration Guide
-
8/10/2019 BSC6810V200R011 Global and Equipment Data Configuartion
4/67
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 4
Chapter 1 Data Configuration Overview
Chapter 2 Global Data Configuration
Chapter 3 Equipment Data Configuration
-
8/10/2019 BSC6810V200R011 Global and Equipment Data Configuartion
5/67
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 5
Local Maintenance Terminal ( MML Client )
The local maintenance terminal is an item of the LMT software.
The local maintenance terminal adopts the GUI and the MML
(Man Machine Language) to operate and maintain the system.
Note: Data configuration is realized by the MML commands.
-
8/10/2019 BSC6810V200R011 Global and Equipment Data Configuartion
6/67
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 6
Application Scenarios of MML Deployment
During the deployment, engineers should configure BSC6810 data
configuration script according to the negotiation data for stand alone
RNC during initial setupand run the script by MML commands in
batches.
Modify data in batch mode
When the RNP or RNO engineers need to modify mass incumbent
BSC6810 configuration data, they can modify BSC6810 configuration
data through running MML command script in batch mode.
Modify a few configuration data
When a few configuration data need to be modified, every single MML
command can be run to execute the function.
-
8/10/2019 BSC6810V200R011 Global and Equipment Data Configuartion
7/67HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 7
Open LMT
Choose Start > All Programs >
Huawei Local Maintenance
Terminal > Local Maintenance
Terminal.
On BSC6810 Local
Maintenance Terminal, choose
System > Execute MML Client.
On BSC6810 Local
Maintenance Terminal, click theicon to start the Local
Maintenance Terminal.
Use one of the following 3 methods to start the HUAWEI LMT
: Consider the different between Local and EMS?
-
8/10/2019 BSC6810V200R011 Global and Equipment Data Configuartion
8/67
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 8
InterfaceMenu bar
Tool bar
Command
window
Output window
Status bar
Navigation tree
-
8/10/2019 BSC6810V200R011 Global and Equipment Data Configuartion
9/67
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 9
Data Configuration Methods
1.Offline data configuration
2.Online data configuration
.dat filesBoards
of FAM
BAM
Configuration
MML commandsDatabase
Loading
by resetting
FormattingLMT
..dat files
Boards of
FAM
BAM
Configuration
MML commandsDatabase
Loadingdirectly
FormattingLMT
-
8/10/2019 BSC6810V200R011 Global and Equipment Data Configuartion
10/67
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 10
Offline Data Configuration
Parameters input
Help information
of command
Command
input
Command display
Save = F9
-
8/10/2019 BSC6810V200R011 Global and Equipment Data Configuartion
11/67
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 11
Offline Data Configuration When the system is offline, and F9 are used to save the input
command.
When you click or
press F9 the first time
after you enter the
command, the system
displays the save dialog
box. If you want to save
the command, you must
specify the mandatory
parameters.
The default path for saving input commands is: LMT installation directory
\ client \ output \ BSC6810 \ version number \ batch \.
-
8/10/2019 BSC6810V200R011 Global and Equipment Data Configuartion
12/67
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 12
Online Data Configuration
The commandexecutes
successful
-
8/10/2019 BSC6810V200R011 Global and Equipment Data Configuartion
13/67
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 13
Running MML Commands in Batches
Running MML commands in batches refers to running multiple MML commands at a time. The
pre-edited batch file is run on the Local Maintenance Terminal so that you do not need to
manually run every MML command.
The batch file is a plain text file. It contains a group of command scripts for a special task. The
system automatically runs the commands in sequence.
You can run MML commands in batches through two methods: immediate batch command and
timing batch command.
Immediate batch command refers to running the batch file immediately.
Timing batch command: The operator set in advance the date and time
when the batch file is run. The system automatically run the batch file on
the date and at the time.
-
8/10/2019 BSC6810V200R011 Global and Equipment Data Configuartion
14/67
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 14
Immediate Batch Command - Start
-
8/10/2019 BSC6810V200R011 Global and Equipment Data Configuartion
15/67
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 15
Immediate Batch Command
Click . A Set dialog box is displayed.
-
8/10/2019 BSC6810V200R011 Global and Equipment Data Configuartion
16/67
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 16
Timing Batch Command
-
8/10/2019 BSC6810V200R011 Global and Equipment Data Configuartion
17/67
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 17
Timing Batch Command
Select the Timing Batch Command tab page.
Click . A Add Batch Task dialog box is displayed.
Click . The Open dialog box is displayed. Select the pre-
edited batch file.
Click to refresh Add Batch Task dialog box .
Set all the parameters in Add Batch Task dialog box, and
then click to refresh Timing Batch Command tab
page.i Caution: Do not close the MML Batch dialog box. If you closeit, the batch task will be deleted.
-
8/10/2019 BSC6810V200R011 Global and Equipment Data Configuartion
18/67
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 18
Data Configuration Overview
Configuration Command Action Description
Action Meaning
ADD Add an object
SET Set an object
LST Query BAM database configuration information
DSP Query FAM object state or BAM running state
MOD Modify an object
RMV Remove an object
ACT Activate an object
DEA Deactivate an object
RST Reset an object
What is different between ADD and SET ?
What is different between LST and DSP ?
-
8/10/2019 BSC6810V200R011 Global and Equipment Data Configuartion
19/67
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 19
Data Configuration Overview
Data Configuration Control
BSC6810 controls whether LMT or M2000 has the permission
to configure the data at a time to avoid the data conflict
Check the status of CMC (REQ CMCTRL)
Procedure of obtaining CMC in different cases
Lock CMC
If Then
M2000 communicates with BSC6810 normally
Use the REQ CMCTRLcommand to request the CMC.
If M2000 approves, LMT will get it
M2000 cannot communicate with BSC6810 or
BSC6810 is not equipped with M2000
Use the FOC CMCTRLcommand to obtain the CMC
forcibly
-
8/10/2019 BSC6810V200R011 Global and Equipment Data Configuartion
20/67
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 20
Data Configuration Overview
Configuration procedures of initial setup RNC
Global dataconfiguration
Equipment dataconfiguration
Interface dataconfiguration
Cell data configuration
Start
End
BSC6810
BSC6810
NodeB
NodeB
NodeB
MSC Server
MGW
SGSN
UE UTRAN CNUu Iu
Iu-CS
Iu-PS
Iur
Iub
Iub
-
8/10/2019 BSC6810V200R011 Global and Equipment Data Configuartion
21/67
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 21
Chapter 1 Data Configuration Overview
Chapter 2 Global Data Configuration
Chapter 3 Equipment Data Configuration
-
8/10/2019 BSC6810V200R011 Global and Equipment Data Configuartion
22/67
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 22
Global Data Configuration Procedure
End
Start
Adding RNC basic data
Adding original signaling
point data
Activate license file
Adding RNC global location
Adding local M3UA entity
Global parameter is used to identify the
RNC in a network.
This is the first step of RNC initial
configuration, use SET OFFLINE
command switch RNC all
subrack to offline mode.
During the RNC initial configuration,
global data include several necessary
steps as shown in right procedure flow.
-
8/10/2019 BSC6810V200R011 Global and Equipment Data Configuartion
23/67
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 23
ConfigureRNC Basic Data Information
ADD RNCBASIC :offline mandatory
SET OPERATORSHARINGMODE:optional
ADD CNOPERATOR: offline mandatory
ADD CNOPERGROUP :mandatory
SET OPERATORCFGPARA:optional
SET SUBNET : optional
SET SCTPSVRPORT: optional
End
Start
Adding RNC basic data
Adding original signaling
point data
Activate license file
Adding RNC global location
Adding local M3UA entity
-
8/10/2019 BSC6810V200R011 Global and Equipment Data Configuartion
24/67
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 24
The command is an offline command which can only be executed in offline mode.
RNC id range is 0-4096 and used to uniquely identifying an RNC in same
operator network.
ATM address: use to distinguish equipment in ATM transmission network.
ConfigureRNC Basic Data Information
Paramters of ADD RNCBASIC command
-
8/10/2019 BSC6810V200R011 Global and Equipment Data Configuartion
25/67
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 25
Paramters of SET OPERATORSHARINGMODEcommand
RAN Sharing Support: Multiple operators to share a set
of RAN equipment that covers the same area.
MOCN: Multi-operator share frequency resource mode.
Intra RAT Inter Plmn Ho Allowed: Intra Plmn handover.
Inter RAT Inter Plmn Ho Allowed: Inter Plmn handover.
ConfigureRNC Basic Data Information
RNC1
Operator 2
RNC2
RNC3
Operator 1
-
8/10/2019 BSC6810V200R011 Global and Equipment Data Configuartion
26/67
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 26
Configure RNC Basic Data Information
Paramters of ADD CNOPERATOR command
Cn Operator Name: Value range: String long 1 ~ 31
Mobile country code: MCC Value range: 000 to 999
Mobile network code: MNC Value range: 00 to 99 or 000 to 999
Cn Operator index: Value range: 5-31
-
8/10/2019 BSC6810V200R011 Global and Equipment Data Configuartion
27/67
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 27
PRIM:Primary operator, determines functions to be supported the entire RAN system
and allocates licenses to secondary operators. The primary operator permits registration
and access the UE.
SEC:Secondary operator, functions to be supported the entire RAN system and the
license of the secondary operators are controlled by primary operator. Secondary
operator permit access UE.
OUTER:Outer operator, In mobility management, UEs need to be hand over from the
operator of the source RNC to the operator of the target RNC. If the operator is not the
primary operator and secondary operator of the source RNC, you need to specify the
operator as an outer operator so that the operator support the mobility management.
COMM:operator that supports non-support UEs, The PLMN ID indicated in the system
broadcast information as defined for conversational networks, which non-support UEs
understand as the serving opertaor.
Configure RNC Basic Data Information
-
8/10/2019 BSC6810V200R011 Global and Equipment Data Configuartion
28/67
-
8/10/2019 BSC6810V200R011 Global and Equipment Data Configuartion
29/67
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 29
Configure RNC Basic Data Information
Paramters of ADD CNOPERATOR command
In one operator group, can be configure 1-4 real operator index
In one operator group, can choose to configure one common operator index.
CNOPERATORGROUP is to facilitate maintenance and management.
-
8/10/2019 BSC6810V200R011 Global and Equipment Data Configuartion
30/67
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 30
Configure RNC Basic Data Information
Paramters of SET OPERATORCFGPARA command
If the RNC system support IU-FLEX and MOCNthis command use to configure
NRI parameter.NRI (network recourse identifier) is part of the temporary indentity TMSI (CS
domain) or P-TMSI (PS domain), which is assigned by the serving CN node to the
UE.
-
8/10/2019 BSC6810V200R011 Global and Equipment Data Configuartion
31/67
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 31
Set RNC Internal Subnet No.
WRBS
SCU
80.x.x.x
Configure RNC Basic Data Information
WRBS
BAM
External
BAM
Internal
-
8/10/2019 BSC6810V200R011 Global and Equipment Data Configuartion
32/67
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 32
Parameter of SET SCTPSRVPORT command.
Configure RNC Basic Data Information
The default parameter:
NBAP port No. is 58085.
M3UA port No. is 2910.
-
8/10/2019 BSC6810V200R011 Global and Equipment Data Configuartion
33/67
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 33
Configure Original Signaling Point Data
ADD OPC: offline mandatory
End
Start
Adding RNC basic data
Adding original signaling
point data
Activate license file
Adding RNC global location
Adding local M3UA entity
-
8/10/2019 BSC6810V200R011 Global and Equipment Data Configuartion
34/67
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 34
Parameter of ADD OPC command
Configure Original Signaling Point Data
OSP name: 1~31 characters.
Network ID:
INT: international network.
INTB: international reserved.
NAT: national network.
NATB: national reserved.
-
8/10/2019 BSC6810V200R011 Global and Equipment Data Configuartion
35/67
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 35
Configure Original Signaling Point Data
OSP code bits: Value range: BIT14, BIT16, BIT24.
OSP code: negation data. Value range:
H'1~H'3FFF(1~16383),H'1~H'FFFF(1~65535), H'1~H'FFFFFF(1~16777215).
or BIT24
BIT16 osp code without restart switch.
-
8/10/2019 BSC6810V200R011 Global and Equipment Data Configuartion
36/67
-
8/10/2019 BSC6810V200R011 Global and Equipment Data Configuartion
37/67
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 37
Activate License File
Activate License File
i Notice: The license file located in\BAM\FTP\LICENSE
-
8/10/2019 BSC6810V200R011 Global and Equipment Data Configuartion
38/67
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 38
Configure Global Location Data
ADD LAC:mandatory
ADD RAC:mandatory
ADD SAC: mandatory
ADD URA:mandatory
ADD CZ:optional
End
Start
Adding RNC basic data
Adding original signaling
point data
Activate license file
Adding RNC global location
Adding local M3UA entity
-
8/10/2019 BSC6810V200R011 Global and Equipment Data Configuartion
39/67
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 39
ADD LAC: Add location area code
ADD RAC: Add route area code
ADD SAC: Add service area code
ADD URA: Add UTRAN Registration Area
PLMN: Public Land Mobile Network
Configure Global Location Data
LAC1
RAC1
RAC2
SAC1 SAC2 LAC2
PLMN
-
8/10/2019 BSC6810V200R011 Global and Equipment Data Configuartion
40/67
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 40
UE States
CELL_DCH CELL_FACH
CELL_PCHURA_PCH
IDLE
DEAD - Scanning networks (PLMN)- Camp on cell
- Monitor paging channel- cell re-selection
- Dedicated Channel- Radio bearers Transmission Services
- upper layer Signalingtrigger (CN)
- Reduce actionDRXand save power
RRC con nect ion
Configure Global Location Data
-
8/10/2019 BSC6810V200R011 Global and Equipment Data Configuartion
41/67
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 41
Parameter of ADD LAC command
Configure Global Location Data
LAI (location area identity)=MCC+MNC+LACPLMN value range should without intersection between LAC and RAC
-
8/10/2019 BSC6810V200R011 Global and Equipment Data Configuartion
42/67
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 42
Parameter of ADD RAC command
Configure Global Location Data
RAI (Route area identity) =MCC+MNC+LAC+RAC
-
8/10/2019 BSC6810V200R011 Global and Equipment Data Configuartion
43/67
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 43
Parameter of ADD SAC command
Configure Global Location Data
SAI (Source area identity) =MCC+MNC+LAC+SAC
-
8/10/2019 BSC6810V200R011 Global and Equipment Data Configuartion
44/67
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 44
Parameter of UTRAN Registration Area command
Configure Global Location Data
Parameter of CZ command
-
8/10/2019 BSC6810V200R011 Global and Equipment Data Configuartion
45/67
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 45
Configure Local M3UA Entity
End
Start
Adding RNC basic data
Adding original signaling
point data
Activate license file
Adding RNC global location
Adding local M3UA entityADD M3LE: IP network mandatory
This command only use for IU interface IP network.
The prerequisite is OPC configured.
This command and IU interface IP configuration,
the detail information please see
-
8/10/2019 BSC6810V200R011 Global and Equipment Data Configuartion
46/67
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 46
Chapter 1 Data Configuration Overview
Chapter 2 Global Data Configuration
Chapter 3 Equipment Data Configuration
E i D C fi i
-
8/10/2019 BSC6810V200R011 Global and Equipment Data Configuartion
47/67
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 47
Equipment Data Configuration
Equipment data configuration is used to
identify the subracks, boards and clock
information of RNC.
This is the second configuration step of
RNC initial configuration.
During the RNC initial configuration,
equipment data include several necessary
steps as shown in the right procedure flow.
Adding the IP Address of the EMS Server
End
Start
Setting RNC
Equipment Description
Adding Basic Data of the RSS
Adding Basic Data of the RBS
Adding an EMU
Configuring RNC Clock Data
Setting RNC Time
S i RNC E i D i i
-
8/10/2019 BSC6810V200R011 Global and Equipment Data Configuartion
48/67
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 48
Setting RNC Equipment Description
SET SYS: mandatory
Adding the IP Address of the EMS Server
End
Start
Setting RNCEquipment Description
Adding Basic Data of the RSS
Adding Basic Data of the RBS
Adding an EMU
Configuring RNC Clock Data
Setting RNC Time
S tti RNC E i t D i ti
-
8/10/2019 BSC6810V200R011 Global and Equipment Data Configuartion
49/67
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 49
Parameter of SET SYS command
The RNC equipment description is stored only in the BAM database and is not sent to the host.
The actual description of each parameter should fill according to the requirement of customer
Setting RNC Equipment Description
Addi B i D t f th RSS
-
8/10/2019 BSC6810V200R011 Global and Equipment Data Configuartion
50/67
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 50
Adding Basic Data of the RSS
MOD SUBRACK: mandatory
SET CLKTYPE: mandatory
ADD BRD: mandatory
SET MSP: optional
Adding the IP Address of the EMS Server
End
Start
Setting RNCEquipment Description
Adding Basic Data of the RSS
Adding Basic Data of the RBS
Adding an EMU
Configuring RNC Clock Data
Setting RNC Time
Addi B i D t f th RSS
-
8/10/2019 BSC6810V200R011 Global and Equipment Data Configuartion
51/67
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 51
Parameter of MOD SUBRACK command
Adding Basic Data of the RSS
Parameter of SET CLKTYPE command
Addi B i D t f th RSS
-
8/10/2019 BSC6810V200R011 Global and Equipment Data Configuartion
52/67
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 52
Parameter of ADD BRD command
Adding Basic Data of the RSS
Back up: This parameter indicates whether the board is backup or not.
Addi B i D t f th RSS
-
8/10/2019 BSC6810V200R011 Global and Equipment Data Configuartion
53/67
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 53
Adding Basic Data of the RSS
Parameter of ADD BRD command
UCP: UMTS RNC Control plane Process=SPU
RUCP: Resource Management and UMTS RNC Control plane Process= MPU
UUP: UMTS RNC User plane Process = DPU
Adding Basic Data of the RBS
-
8/10/2019 BSC6810V200R011 Global and Equipment Data Configuartion
54/67
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 54
Adding Basic Data of the RBS
ADD SUBRACK: mandatory
ADD BRD: mandatory
SET MSP: optional
Adding the IP Address of the EMS Server
End
Start
Setting RNCEquipment Description
Adding Basic Data of the RSS
Adding Basic Data of the RBS
Adding an EMU
Configuring RNC Clock Data
Setting RNC Time
Adding Basic Data of the RBS
-
8/10/2019 BSC6810V200R011 Global and Equipment Data Configuartion
55/67
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 55
Parameter of ADD SUBRACK
Adding Basic Data of the RBS
Adding an EMU
-
8/10/2019 BSC6810V200R011 Global and Equipment Data Configuartion
56/67
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 56
Adding an EMU
ADD EMU: Optional
Adding the IP Address of the EMS Server
End
Start
Setting RNCEquipment Description
Adding Basic Data of the RSS
Adding Basic Data of the RBS
Adding an EMU
Configuring RNC Clock Data
Setting RNC Time
-
8/10/2019 BSC6810V200R011 Global and Equipment Data Configuartion
57/67
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 57
Adding an EMU
Parameter of ADD EMU
Configuring RNC Clock Data
-
8/10/2019 BSC6810V200R011 Global and Equipment Data Configuartion
58/67
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 58
Configuring RNC Clock Data
SET CLK: mandatory
ADD CLKSRC: mandatory
SET CLKMODE: mandatory
Adding the IP Address of the EMS Server
End
Start
Setting RNCEquipment Description
Adding Basic Data of the RSS
Adding Basic Data of the RBS
Adding an EMU
Configuring RNC Clock Data
Setting RNC Time
Configuring RNC Clock Data
-
8/10/2019 BSC6810V200R011 Global and Equipment Data Configuartion
59/67
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 59
Configuring RNC Clock Data
Parameter of SET CLK command
1. You can set the clock source of interface boards in the RSS to backplane 8 K output clock sourcewhich cannot be set for that of interface boards in the RBS.
2. You can choose 0 to 31 as the link number when setting the clock source for the AEU and PEU.
You can choose 0 and 1 as the link number when setting the clock source for the AOU.
You can choose 0 to 3 as the link number when setting the clock source for the UOI.
Configuring RNC Clock Data
-
8/10/2019 BSC6810V200R011 Global and Equipment Data Configuartion
60/67
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 60
Configuring RNC Clock Data
Parameter of ADD CLKSRC command
1 (Top priority)
2 (High priority)
3 (Low priority)
4 (Lower priority)
0 (Lowest priority =Local Clock)
LINE1-8KHZ
LINE2-8KHZ
Can be get from interface board or external clock source such as BITS
provide two channels of 8 kHz clock signals that are locked
at the interface boards and transported to the backplane.
Is the independent clock source and input from com1 of GCUa board
BITS1-2MHZ
BITS2-2MHZ
BITS1-2MBPS
BITS2-2MBPS
8KHZ
Configuring RNC Clock Data
-
8/10/2019 BSC6810V200R011 Global and Equipment Data Configuartion
61/67
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 61
Configuring RNC Clock Data
Parameter of SET CLKMODE command
Manual: The user specifies a clock source and inhibits it from automatically
being handed over to other sources.
Auto: The user is not required to specify a clock source and the system is able to
select the clock source with the highest priority automatically.
-
8/10/2019 BSC6810V200R011 Global and Equipment Data Configuartion
62/67
Configuring RNC Clock Data
-
8/10/2019 BSC6810V200R011 Global and Equipment Data Configuartion
63/67
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 63
Configuring RNC Clock Data
SET TZ: mandatory
ADD SNTPSRVINFO:optional
SET SNTPCLTPARA: optional
Adding the IP Address of the EMS Server
End
Start
Setting RNCEquipment Description
Adding Basic Data of the RSS
Adding Basic Data of the RBS
Adding an EMU
Configuring RNC Clock Data
Setting RNC Time
-
8/10/2019 BSC6810V200R011 Global and Equipment Data Configuartion
64/67
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 64
SNTP
serverSNTP server
SNTP client
SNTP clientSNTP server
RNC NodeBM2000
Configuring RNC Clock Data
RNC external network view: M2000 is the SNTP server of RNC
RNC is the SNTP client of M2000.
RNC internal network view: RNC is the SNTP server of NodeB
NodeB is the SNTP Client of RNC.
Config ring RNC Clock Data
-
8/10/2019 BSC6810V200R011 Global and Equipment Data Configuartion
65/67
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 65
Configuring RNC Clock Data
SNTP: Simple network time protocol.
SNTP server IP is the IP address of M2000. Port number is 123.
The number of the SNTP Servers cannot exceed 16.
If multiple SNTP servers are configured, SNTP Client chooses the best
SNTP server as the clock source according to the algorithm defined in
the NTP protocol.
Parameter of SET SNTPCLTPARA command
Configuring RNC Clock Data
-
8/10/2019 BSC6810V200R011 Global and Equipment Data Configuartion
66/67
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 66
Configuring RNC Clock Data
ADD EMSIP: mandatory for M2000 IP.
Detail see interface configurationAdding the IP Address of the EMS Server
End
Start
Setting RNCEquipment Description
Adding Basic Data of the RSS
Adding Basic Data of the RBS
Adding an EMU
Configuring RNC Clock Data
Setting RNC Time
-
8/10/2019 BSC6810V200R011 Global and Equipment Data Configuartion
67/67
Thank You
www.huawei.com