BRIDGE ENGINEERING ASSOCIATION 2005 NEW YORK CITY BRIDGE CONFERENCE SEPTEMBER 12-13, 2005 Dynamic and Static Displacement Monitoring with Non- contacting Interferometric Radar System NJ Route 23 Bridge - Structure No. 1618-150 Over US 202, Ramps M & N and Norfolk Southern Railroad Wayne Township near Passaic, New Jersey Eugenia K. Roman, P.E. Vice President Olson Engineering, Inc. New Jersey - Colorado - New Mexico

Upload: crystal-southwood

Post on 16-Dec-2015

214 views

Category:

Documents


0 download

TRANSCRIPT

BRIDGE ENGINEERING ASSOCIATION 2005 NEW YORK CITY BRIDGE CONFERENCE

SEPTEMBER 12-13, 2005

Dynamic and Static Displacement Monitoring with Non-contacting Interferometric Radar System

NJ Route 23 Bridge - Structure No. 1618-150Over US 202, Ramps M & N and Norfolk Southern Railroad

Wayne Township near Passaic, New Jersey

Eugenia K. Roman, P.E.Vice President

Olson Engineering, Inc.

New Jersey - Colorado - New Mexico

BRIDGE ENGINEERING ASSOCIATION 2005 NEW YORK CITY BRIDGE CONFERENCE

SEPTEMBER 12-13, 2005

The IBIS-S system is a Stepped-Frequency Continuous Wave (SF-CW) coherent radar with Interferometric capabilities, dedicated to remote monitoring of static or dynamic displacements of civil structures.

IBIS-S System Principle Description

Displacement is measured by comparing phase information from the reflected airborne radar waves, which are collected at time intervals.

TX

RX

TX

RX

d

TX

RX

TX

RX

d1

2

BRIDGE ENGINEERING ASSOCIATION 2005 NEW YORK CITY BRIDGE CONFERENCE

SEPTEMBER 12-13, 2005

IBIS-S System Principle Description• IBIS-S Radar system is a 1-

D measurement tool, measuring displacement in the line of sight of the radar unit

• Separate targets at the same distance from the radar are averaged into a single reflection echo

• The separation between targets must be at least 2.5 ft (0.75 m)• AKA called the range

bin size

• The shape of the transmitted radar beam can be manipulated with different horn attachments to focus on targets of interest.

BRIDGE ENGINEERING ASSOCIATION 2005 NEW YORK CITY BRIDGE CONFERENCE

SEPTEMBER 12-13, 2005

The IBIS-S measures displacement in the direction of the line of sight of the system. Knowledge of the acquisition geometry is used to calculate the real vertical displacement.

The calculation necessarily assumes that the horizontal displacement is zero.

Rh

d

dp

α

h

Rdd p

R

h)sin(

)sin(pd

d The distance R is measured by

IBIS-S

IBIS-S System Principle Description

BRIDGE ENGINEERING ASSOCIATION 2005 NEW YORK CITY BRIDGE CONFERENCE

SEPTEMBER 12-13, 2005

IBIS-S Set-up

• IBIS-S positioned directly under the centerline of Pier 1W looking North at Span 2

BRIDGE ENGINEERING ASSOCIATION 2005 NEW YORK CITY BRIDGE CONFERENCE

SEPTEMBER 12-13, 2005

IBIS-S Set-up

• Three corner reflectors were installed on girder 2W3 in order to:

• create more distinguishable reflection points along the structure

• to provide direct comparison data with installed string potentiometers

BRIDGE ENGINEERING ASSOCIATION 2005 NEW YORK CITY BRIDGE CONFERENCE

SEPTEMBER 12-13, 2005

IBIS-S Radar Reflection Amplitudes

BRIDGE ENGINEERING ASSOCIATION 2005 NEW YORK CITY BRIDGE CONFERENCE

SEPTEMBER 12-13, 2005

IBIS-S Dynamic Results of Ambient Traffic Data

• Example time domain displacement vibration data due to typical traffic loading.

• An FFT was applied to ambient vibration data in order to determine the resonant frequency of the structure.

• The bridge span had an apparent resonant frequency of 2.76 Hz.

• In more extensive studies modal shapes can also be determined.

BRIDGE ENGINEERING ASSOCIATION 2005 NEW YORK CITY BRIDGE CONFERENCE

SEPTEMBER 12-13, 2005

Load Tests results of the three corner reflectors with loads at ~ ¾, ½, and ¼ Spans, six loaded trucks, load test duration ~ 1 hr

IBIS-S Static Load Test Results

0.85” (21.76 mm)

0.58” (14.69 mm) 0.58” (14.84 mm)

BRIDGE ENGINEERING ASSOCIATION 2005 NEW YORK CITY BRIDGE CONFERENCE

SEPTEMBER 12-13, 2005

IBIS-S Test Result Conclusions

• The system can be installed very quickly and easily

• Accurate to 0.0004 inch (1/100 mm)

• The system is simple to use and the resulting data is easy to analyze and easily understood due to the actual measurement of displacement.

• The system can provide access to otherwise difficult structures.

• The system is extremely accurate and can provide both dynamic and static displacements.

• Overall, the system is ideally suited for rapid load testing of bridges with minimal interference due to access and incredible potential of the quantity, quality, and accuracy of measured data.