beam to column flange connection
DESCRIPTION
Steel StructuresBeam to Column Flange Connection.TRANSCRIPT
Job: to design a beam to column flange simple connection with high strength friction bolts to a
given shear force Ved.
Preliminary Data:
Steel S275
Beam IPE 450
Column HEA 340
Plate 12mm
VEd=550kN
Column HEA340, S275
Depth
Width
Thickness of the web
Thickness of the flange
Fillet radius
Area
hc 330mm:=
bc 300mm:=
twc 9.5mm:=
tfc 16.5mm:=
r 27mm:=
Ac 133.5mm2
:=
Beam IPE450, S275
Depth
Width
Thickness of the web
Thickness of the flange
Fillet radius
Area
hb 450mm:=
bb 190mm:=
twb 9.4mm:=
tfb 14.6mm:=
rb 21mm:=
Ab 98.8mm2
:=
Plate S275
tp 12mm:=Thickness
Yield s trength
Ultimate tensile strength
fy 275N
mm2
:=
fup 430N
mm2
:=
HSF Bolts M22 grade 10.9:
Tensile stress area As 303mm2
:=
Diameter of the shank d 22mm:=
Diameter of the holes d0 24mm:=
Diameter of the washer dw 50mm:=
fyb 900N
mm2
:=Yield s tregth
Ultimate tensile stregth fub 1000N
mm2
:=
αv 0.5:=
Design Shear Force:
VEd 550kN:=
Partial Safety Factors:
γM0 1:=
γM2 1.25:= (for shear resistance in ULS)
γM3 1.25:=
γMu 1.1:= (for tying resistance in ULS)
Abstract - High strength friction bolts
High strength friction bolts produce compressive stress on the connecting
plates, increasing their frictional resistance and allowing the transfer of shear force
between them.
Preloading of bolts:
n 4:= no. of bolts
Fp.Cd n 0.7⋅ fub⋅ As⋅ 848.4 kN⋅=:=
Resistance of the high strength friction bolts connection between plates and
column
Number of friction faces:
nf 2:=
Slip factor µ for treated surfaces:
µ 0.5:=
Friction force for one bolt:
Fs.Rd
nf µ⋅ Fp.Cd⋅
γM3
678.72 kN⋅=:=
Friction will resist the Shear Force.
Conclusion :
High strength friction bolts are used because of their greater stiffness,their
capacity to bear alternative forces and their better fatigue resistance compared with
normal bolts.
They need more care and trained workers and they are more expensive.
So,in our case,we better use the normal bolted connections.
The rest of the checkings will be done like they were done for normal
bolted connection.
Weld design(S275)
a 0.48 twb⋅ 4.512 mm⋅=:=
Choose as a=5mm welding.
Plate design
The plate height
hp hb 2 100⋅ mm− 250 mm⋅=:=
From Eurocode 1993-1-8:
Minimum
e1 1.2 d0⋅ 28.8 mm⋅=:=
e2 1.2 d0⋅ 28.8 mm⋅=:=Maximum
e1 4 tp⋅ 40mm+ 88 mm⋅=:=
e2 4tp 40mm+ 88 mm⋅=:=
Choose e1 80mm:= ., e2 50mm:=p1 2.2d0 52.8 mm⋅=:=
p2 2.4d0 57.6 mm⋅=:=
p1 hp e1− e1− 90 mm⋅=:=
.
.
p2 e2 tfb+ e2+ 114.6 mm⋅=:=
p2 115mm:=
The plate base will have the dimension:
bp e2 p2+ e2+ 215 mm⋅=:=
tp 12mm:=
We will have one plate 250x215x12 with 4 bolts.
Joint shear resistance
Beam Web in Shear
Av 0.9 hp⋅ twb 2 tfb⋅+( )⋅ 8.685 103
× mm2
⋅=:=
VRd7
Av fyb⋅1
3⋅
γM0
4.513 103
× kN⋅=:=
End plate in bearing
e1
3d0
1.111=p1
3 d0⋅
1
4− 1=
fub
fup
2.326=
αb is the minimum of the above 3 relations:
αb minp1
3 d0⋅
1
4−
e1
3d0
, fub
fup
,
1=:=
2.8e2
d0
⋅ 1.7− 4.133=
k1 min 2.5 2.8e2
d0
⋅ 1.7−,
2.5=:=
FbRd
k1 αb⋅ fup⋅ d⋅ tp⋅
γM2
227.04 kN⋅=:=
VRd2 0.8 4⋅ FbRd⋅ 726.528 kN⋅=:=
Joint tying resistance
Bolts in shear
The bolts are not subjected to shear.
End Plate in Bearing
αb2 mine2
3d0
fub
fup
, 1,
0.694=:=
k12 min 2.8e1
d0
⋅ 1.7− 1.4p1
d0
1.7−, 2.5,
2.5=:=
Fb.Rd.u.hor
k12 αb2⋅ fup⋅ d⋅ tp⋅
γMu
179.167 kN⋅=:=
NRd.u.2 n Fb.Rd.u.hor⋅ 716.667 kN⋅=:=
Column Flange in Bearing
e2c e2 95mm+ 145 mm⋅=:=
αb3 mine2c
3d0
fub
fup
, 1,
1=:=
k13 min 1.4p1
d0
1.7− 2.5,
2.5=:=
Fb.Rd.u.hor2
k1 αb⋅ fup⋅ d⋅ tfc⋅
γMu
354.75 kN⋅=:=
NRd.u.5 n Fb.Rd.u.hor2⋅ 1.419 103
× kN⋅=:=
Joint shear resistance•VRd2 726.528 kN⋅=
VRd7 4.513 103
× kN⋅=
Joint tying resistance•
NRd.u.2 716.667 kN⋅=
NRd.u.5 1.419 103
× kN⋅=
All the resistances have values above the design load value,so the design
is good.