barrel alignment platform positioning goal: positioning of the platforms at their nominal position...
TRANSCRIPT
![Page 1: BARREL ALIGNMENT PLATFORM POSITIONING Goal: Positioning of the platforms at their nominal position on the MDT chambers (No position measurement in a database)](https://reader036.vdocuments.mx/reader036/viewer/2022082818/56649f1b5503460f94c30f9a/html5/thumbnails/1.jpg)
BARREL ALIGNMENT PLATFORM POSITIONING
Goal:• Positioning of the platforms at their nominal position on the MDT chambers (No position measurement in a database).
Principle: • Use a precisely adjusted template squares (precision < 10 m) to hold the platform at their nominal position during the glue curingw.r.t. the endplugs (2 points) and the outer tube surface or on the jig (BOS only) at the level of the first comb.
Flat surface on endplugs
Half sphere on end plugs
6 adjustable (on CMM) balls for the platform positioning
Half sphere on thetube outer surface oron the jig (BOS)
C. Guyot (Saclay) Dubna 06/2000
![Page 2: BARREL ALIGNMENT PLATFORM POSITIONING Goal: Positioning of the platforms at their nominal position on the MDT chambers (No position measurement in a database)](https://reader036.vdocuments.mx/reader036/viewer/2022082818/56649f1b5503460f94c30f9a/html5/thumbnails/2.jpg)
Praxial platform positioning tools:Top view
Bottom view
![Page 3: BARREL ALIGNMENT PLATFORM POSITIONING Goal: Positioning of the platforms at their nominal position on the MDT chambers (No position measurement in a database)](https://reader036.vdocuments.mx/reader036/viewer/2022082818/56649f1b5503460f94c30f9a/html5/thumbnails/3.jpg)
Positioning in x of the template tools on the tube layer:
Tube with calibrated length (+- 50 m)
Ruler with straigthness < 100 m
Platform screwed on the positioning square
![Page 4: BARREL ALIGNMENT PLATFORM POSITIONING Goal: Positioning of the platforms at their nominal position on the MDT chambers (No position measurement in a database)](https://reader036.vdocuments.mx/reader036/viewer/2022082818/56649f1b5503460f94c30f9a/html5/thumbnails/4.jpg)
The optical control tools
Goal: • Check the platform orientation (angles) during the tube layer assembly( Reminder: The platforms are glued on the first layer)• Register on a database the values of the angles measured after only one tube layer glued (i.e. right after the platform gluing) and the angles mesured at the end of the multilayer assembly. For the module 0 assembly, register the values after each tube layer assembly (Not possible on BIL due to the stiff back geometry).
Principle: 4 tools (towers) carrying 2 cameras and 2 LEDs looking at each neighbour
2 leds
CMOS image sensor
lens
f~ 80 mm (except for BIS transverse: 60 mm)
Plateform angle ~ (X/Y(pixel) - X0/Y0) * pixel_size / f
Average led spot coordinate From the calibration on the granite table
![Page 5: BARREL ALIGNMENT PLATFORM POSITIONING Goal: Positioning of the platforms at their nominal position on the MDT chambers (No position measurement in a database)](https://reader036.vdocuments.mx/reader036/viewer/2022082818/56649f1b5503460f94c30f9a/html5/thumbnails/5.jpg)
Measured platform angles
y12
x12
y14
x14
y43
x43
y41
x41
y21
x21
y23x23
y34
x34
y32
x32
Tower 1
Tower 3
Tower 2
Tower 4
Zch
Xch
Image sensor axis (pixel direction)
Signal sideHV side
Rotation of platform 1 around Xch axis: X = (X14-X014)/f
Rotation of platform 1 around Ych axis: Y = - (Y12-Y012)/f = - (Y14-Y0
14)/f Rotation of platform 1 around Zch axis: Z = - (X12-X0
12)/f
Rotation of platform 2 around Xch axis: X = (X23-X023)/f
Rotation of platform 2 around Ych axis: Y = (Y21-Y021)/f = (Y23-Y0
23)/f Rotation of platform 2 around Zch axis: Z = (X21-X0
21)/f
Ych
![Page 6: BARREL ALIGNMENT PLATFORM POSITIONING Goal: Positioning of the platforms at their nominal position on the MDT chambers (No position measurement in a database)](https://reader036.vdocuments.mx/reader036/viewer/2022082818/56649f1b5503460f94c30f9a/html5/thumbnails/6.jpg)
Control tool calibration
Longitudinal lines :
Distance adjusted to +- 2mm
Precision wedges
x
zCalibrates rotations around z and y axis
![Page 7: BARREL ALIGNMENT PLATFORM POSITIONING Goal: Positioning of the platforms at their nominal position on the MDT chambers (No position measurement in a database)](https://reader036.vdocuments.mx/reader036/viewer/2022082818/56649f1b5503460f94c30f9a/html5/thumbnails/7.jpg)
Control tool calibration
Transverse lines :
Distance adjusted to +- 2mm
Precision wedges
z
x
Calibrates rotations around x axis only
Square ( 90 degrees +- 1 mrad)
![Page 8: BARREL ALIGNMENT PLATFORM POSITIONING Goal: Positioning of the platforms at their nominal position on the MDT chambers (No position measurement in a database)](https://reader036.vdocuments.mx/reader036/viewer/2022082818/56649f1b5503460f94c30f9a/html5/thumbnails/8.jpg)
•Saclay will supply each MDT lab (barrel) with a set of 4 template squares and a set of 4 control tools (with cables to the RASMUX).
•Each lab will have to provide: - A length calibrated tube - A straight ruler of length ~ chamber width - square width
• The absolute calibration of the control tools will have to doneon a granite table prior to the module 0 assembly.This calibration requires a precision side on the granite table or(better) a precision wedge. If the assembly table on side does not allow such a calibration (no room or no precise side face), this calibration will be done at Saclay (hoping that the image sensor does not move during the transport).