Page 1: B100 Series Technical Specification - dynamicratings.com · Fundamental frequency range: 47 to 63Hz Current resolution: 15uA (0.1% of range) Current accuracy: ± 75uA (±0.5% of range)

www.dynamicratings.com

B100 Series Technical Specification

Rev 4

Page 2: B100 Series Technical Specification - dynamicratings.com · Fundamental frequency range: 47 to 63Hz Current resolution: 15uA (0.1% of range) Current accuracy: ± 75uA (±0.5% of range)

B100 SERIES TECHNICAL SPECIFICATION Rev. 4

Page 2 of 15

© 2017 Dynamic Ratings Specifications and information is subject to change without notice.

Revision History

REVISION DATE

(yymmdd) PUBLISHED BY DESCRIPTION

1 160129 S. Allan, T. Foren Original Release

2 160323 A. Zuehlke, T. Foren,

S. Allan Technical Updates

3 160418 S. Allan Technical Updates

4 170228 M. Morey Updated for Production Release

Contacts

Asia / Africa / Oceania +61 3 9574 7722 [email protected]

Americas / Europe +1 262 746-1230 [email protected]

Page 3: B100 Series Technical Specification - dynamicratings.com · Fundamental frequency range: 47 to 63Hz Current resolution: 15uA (0.1% of range) Current accuracy: ± 75uA (±0.5% of range)

B100 SERIES TECHNICAL SPECIFICATION Rev. 4

Page 3 of 15

© 2017 Dynamic Ratings Specifications and information is subject to change without notice.

CONTENTS

REVISION HISTORY ..................................................................................................... 2

CONTACTS ................................................................................................................... 2

PURPOSE AND SCOPE ................................................................................................ 4

DEFINITIONS ................................................................................................................ 4

NOTICES, CAUTIONS OR WARNINGS ........................................................................ 5

INTRODUCTION ............................................................................................................ 6

HARDWARE FEATURES AND SPECIFICATIONS ....................................................... 6

ENCLOSURE FEATURES ............................................................................................. 7

MECHANICAL DIMENSIONS ........................................................................................ 7

HARDWARE IO OVERVIEW ......................................................................................... 8

BASE MODEL ............................................................................................................ 8

REAL TIME CLOCK (RTC) BATTERY ....................................................................... 8

ETHERNET COMMUNICATIONS OPTIONS ............................................................ 8

SERIAL COMMUNICATIONS OPTIONS ................................................................... 9

IBRIDGE COMMUNICATIONS OPTION ................................................................... 9

POWER SUPPLY ...................................................................................................... 9

I/O TYPE ELECTRICAL DATA .................................................................................... 10

DIGITAL INPUT ....................................................................................................... 10

DIGITAL OUTPUT ................................................................................................... 10

ANALOG OUTPUT – AO ......................................................................................... 11

RESISTANCE TEMPERATURE DETECTOR INPUT – RTD .................................. 11

CURRENT TRANSFORMER INPUT - CT ............................................................... 12

CLIMATIC CONDITIONS ............................................................................................. 13

MECHANICAL CONDITIONS FOR STORAGE AND USE .......................................... 13

MOUNTING .................................................................................................................. 13

HARDWARE STANDARDS COMPLIANCE ................................................................. 14

IEC 61010-1 PART 1: GENERAL REQUIREMENTS............................................... 14

IEC 60870 TELECONTROL EQUIPMENT AND SYSTEMS .................................... 14

IEC 61850 ................................................................................................................ 14

IEC 1613-2003 ......................................................................................................... 14

IEEE C37.90 ............................................................................................................ 14

IEEE C57.12.10-1997 .............................................................................................. 14

FCC PART 15 .......................................................................................................... 14

SALES CONTACTS ..................................................................................................... 15

Page 4: B100 Series Technical Specification - dynamicratings.com · Fundamental frequency range: 47 to 63Hz Current resolution: 15uA (0.1% of range) Current accuracy: ± 75uA (±0.5% of range)

B100 SERIES TECHNICAL SPECIFICATION Rev. 4

Page 4 of 15

© 2017 Dynamic Ratings Specifications and information is subject to change without notice.

FIGURES

FIGURE 1: B100 ............................................................................................................ 6

FIGURE 2: B100 MECHANICAL DIMENSIONS ............................................................ 7

FIGURE 3: VIBRATION MOUNT ASSEMBLY ............................................................. 13

Purpose and Scope

The purpose of this document is to provide a summary of the technical characteristics of the B100 Series Electronic Temperature Monitor (ETM). This information will assist users in understanding B100 I/O and communications, and implementing a B100 series monitor.

Definitions

CT: Current Transformer

DIP: Dual In-Line Package

Form B: Normally closed (NC), single-pole, single-throw (SPST) contacts

Form C: Change over (break-before-make), single-pole, double-throw (SPDT) contacts

I/O: Input / Output

OLTC: On-Load Tap Changer

LCD: Liquid Crystal Display

RNDIS: Remote Network Driver Interface Specification

RS-232: Serial communications link complying with EIA-232

RS-422: Serial communications link complying with EIA-422

RS-485: Serial communications link complying with EIA-485

RTC: Real Time Clock

RTD: Resistance Temperature Detector

WTI: Winding Temperature Indicator/Indication

Page 5: B100 Series Technical Specification - dynamicratings.com · Fundamental frequency range: 47 to 63Hz Current resolution: 15uA (0.1% of range) Current accuracy: ± 75uA (±0.5% of range)

B100 SERIES TECHNICAL SPECIFICATION Rev. 4

Page 5 of 15

© 2017 Dynamic Ratings Specifications and information is subject to change without notice.

Notices, Cautions or Warnings

This document may contain; Notices, Cautions or Warnings using ANSI Z535.5 definitions below.

Alert Symbol ANSI Z535.5 definition

NOTICE: Indicates recommended practices not related to personal injury.

CAUTION: Caution without symbol is used to alert against unsafe practices that can result in property damage only.

CAUTION with symbol: Caution with a symbol indicates a hazardous situation, which, if not avoided could result in minor or moderate injury.

WARNING with symbol: Indicates a potentially hazardous situation, which, if not avoided, can result in injury or serious damage to property.

A notice, caution or warning symbol and its associated message in this document will inform readers of Notices, Cautions or Warnings.

Page 6: B100 Series Technical Specification - dynamicratings.com · Fundamental frequency range: 47 to 63Hz Current resolution: 15uA (0.1% of range) Current accuracy: ± 75uA (±0.5% of range)

B100 SERIES TECHNICAL SPECIFICATION Rev. 4

Page 6 of 15

© 2017 Dynamic Ratings Specifications and information is subject to change without notice.

Introduction Dynamic Ratings is a leading supplier of monitoring and control products to the electrical power industry. The B100 extends the company’s product range and provides a reliable and cost-effective electronic temperature monitor (ETM) and controller with numerous communications options.

Figure 1: B100

Hardware Features and Specifications

The B100 is a single unit housed in an aluminium enclosure, with a day and night readable LCD screen and four external user interface buttons.

The design life of the B100 is 20 years. It is expected to last much longer.

The electrical connections are made using screw terminal blocks, and the unit has multiple cable entry ports at the base of the enclosure. The internal operating system contains many functions to make sure the control system is in a healthy operating condition.

The permitted operating temperature range is -40°C to +70°C (-40°F to 158°F).

Page 7: B100 Series Technical Specification - dynamicratings.com · Fundamental frequency range: 47 to 63Hz Current resolution: 15uA (0.1% of range) Current accuracy: ± 75uA (±0.5% of range)

B100 SERIES TECHNICAL SPECIFICATION Rev. 4

Page 7 of 15

© 2017 Dynamic Ratings Specifications and information is subject to change without notice.

Enclosure Features

The B100 is supplied in a robust cast aluminium enclosure that is rated to IP66 ingress protection (NEMA 4 equivalent). Mounting is via four mounting holes (with supplied vibration mounts) on the sides of the housing. Cable entry is via multiple M20 (3/4 inch) and M25 (1 inch) ports in the bottom of the unit – spare ports are to be sealed to maintain the ingress protection. Additional enclosure features include a Gore® air vent for pressure and temperature compensation, and a padlock loop for locking of the enclosure.

Mechanical Dimensions

Figure 2: B100 Mechanical Dimensions

Page 8: B100 Series Technical Specification - dynamicratings.com · Fundamental frequency range: 47 to 63Hz Current resolution: 15uA (0.1% of range) Current accuracy: ± 75uA (±0.5% of range)

B100 SERIES TECHNICAL SPECIFICATION Rev. 4

Page 8 of 15

© 2017 Dynamic Ratings Specifications and information is subject to change without notice.

Hardware IO Overview Base Model The base model provides the following I/O ports:

1 x USB 2.0 Type B device with USB Ethernet (RNDIS) for configuration and data download

1 GB of on-board memory for configuration and data logging

1 x Form B relay for System Alarm output

6 x Form C relays for alarm outputs

1 x RTD input for main tank temperature input

1 x RTD input for LTC temperature or ambient temperature

3 x CT inputs for load current input and WTI calculation

1 x Digital input for dual winding gradient function

2 x Analog outputs for remote indication

Real Time Clock (RTC) Battery The system contains a user-replaceable “½ AA” 3.6V Lithium Thionyl Chloride real time clock (RTC) battery with an estimated life of ten years. A Tadiran TL-2150 is approved for use.

Ethernet Communications Options The B100 can be supplied with one of the following Ethernet communications options. The ordering option by model number letter is referenced in the parenthesis below:

No Ethernet communications (default selection)

100Base-FX Fiber Ethernet port with SC connectors (compatible with 50/125, 62.5/125, and 100/140 micron glass core multimode fiber)

100Base-FX Fiber Ethernet port with ST connectors (compatible with 50/125, 62.5/125, and 100/140 micron glass core multimode fiber)

100Base-T RS45 Copper Ethernet port

Integrated iBridge communications system (see below).

Page 9: B100 Series Technical Specification - dynamicratings.com · Fundamental frequency range: 47 to 63Hz Current resolution: 15uA (0.1% of range) Current accuracy: ± 75uA (±0.5% of range)

B100 SERIES TECHNICAL SPECIFICATION Rev. 4

Page 9 of 15

© 2017 Dynamic Ratings Specifications and information is subject to change without notice.

Serial Communications Options

The B100 can be supplied with one of the following serial communications options. The ordering option by model number letter is referenced in the parenthesis below:

No serial communications (default selection)

RS-485/RS-422 copper serial port

Serial over fiber port with ST connectors (compatible with 50/125, 62.5/125, and 100/140 micron glass core multimode fiber)

iBridge Communications Option

The iBridge is an affordable communications system utilizing existing conductors that enables rapid installation and data communications to IED communications.

When the B100 is ordered with the iBridge option, the Ethernet and serial ports are replaced with an internal connection to an iBridge module. For more information about the iBridge technical specification, please refer to the Dynamic Ratings iBridge Technical Specifications Manual.

Power Supply

The B100 features a universal wide-input power supply. The power supplies electrical characteristics and input ranges are in the table below.

Standard With iBridge*

AC Frequency 50 – 60 Hz 50 – 60 Hz

AC Input Range 110 – 240 VAC 100 – 240 VAC

DC Input Range 48 – 240 VDC 48 – 240 VDC

Rated Power 28 W 35 W

Table 1: B100 Power Input Ranges

*B100 with iBridge option draws an additional 7W.

Page 10: B100 Series Technical Specification - dynamicratings.com · Fundamental frequency range: 47 to 63Hz Current resolution: 15uA (0.1% of range) Current accuracy: ± 75uA (±0.5% of range)

B100 SERIES TECHNICAL SPECIFICATION Rev. 4

Page 10 of 15

© 2017 Dynamic Ratings Specifications and information is subject to change without notice.

I/O Type Electrical Data

The following I/O types are used in the B100, described here in detail.

Digital Input

The electrical characteristics of digital inputs are:

Absolute maximum voltage input range: ±390 V (276 VAC)

DC voltage range 15 – 390 VDC

AC voltage range 30 – 276 VAC

AC voltage frequency range: 47 to 63 Hz

Each digital input provides the following internal protection:

A self-resetting protection against over current conditions

Protection against over voltage transients and surges

Over voltage protection

Current limiting protection

Digital Output

Digital outputs are hardware relays that are configured in one of two ways:

1 x Form B (Fixed mapping for system alarm)

6 x Form C (User configurable outputs)

Digital outputs do not share any common pins and are electrically isolated. The digital outputs are electrically rated to the following:

Maximum AC carrying capacity: 10 A @ 250 VAC

Maximum DC carrying capacity: 10 A @ 30 VDC, 1 A @ 125 VDC resistive

Maximum making capacity: 30 A

Maximum AC breaking capacity: 3 A @ 120 VAC, 1.5 A @ 240 VAC

Maximum DC breaking capacity: 0.75 A @ 24 VDC, 0.4 A @ 125 VDC, 0.2 A @ 250 VDC

Each digital output provides internal protection against voltage spikes caused by inductive loads.

Page 11: B100 Series Technical Specification - dynamicratings.com · Fundamental frequency range: 47 to 63Hz Current resolution: 15uA (0.1% of range) Current accuracy: ± 75uA (±0.5% of range)

B100 SERIES TECHNICAL SPECIFICATION Rev. 4

Page 11 of 15

© 2017 Dynamic Ratings Specifications and information is subject to change without notice.

Analog Output – AO

Analog outputs do not share any pins and are electrically isolated. Analog outputs may be of either a current sink or voltage output type. Two DIP switches located on the board directly above the outputs are used to switch between volts and milliamps (mA). When the switch is in the up position, volts will be used. When the switch is in the down position, mA will be used. The electrical characteristics of each are:

Analog Current Output

Current range: 0 mA to 24 mA

Current resolution: 24 uA (0.1% of range)

Current accuracy: ±240 uA (±1% of range)

Maximum loop resistance 450 Ω

Analog Voltage Output

Voltage range: 0 V to 10 V

Voltage resolution: 10 mV (0.1% of range)

Voltage accuracy: ±100 mV (±1% of range)

Maximum output current: 5 mA

Each analog output provides protection against over voltage conditions.

Resistance Temperature Detector Input – RTD

An RTD input provides a three conductor connection that is intended to be used with a 3-wire, Pt100 (Platinum 100Ω) RTD. Each RTD input possesses an RTD+, RTD-, and common connection. The electrical characteristics are:

Temperature range: -50°C to +200°C

Temperature accuracy when using IEC 60751 Class A sensors: o ± 0.5°C between 0°C to 100°C o ± 1.0°C between -50°C to 0°C and 100°C to 200°C

Temperature resolution: 0.0625°C

Nominal measuring current: 1mA

Maximum cable resistance per wire 2Ω

Minimum sampling rate: 10 sample per second

Each RTD input provides protection against over voltage conditions.

Page 12: B100 Series Technical Specification - dynamicratings.com · Fundamental frequency range: 47 to 63Hz Current resolution: 15uA (0.1% of range) Current accuracy: ± 75uA (±0.5% of range)

B100 SERIES TECHNICAL SPECIFICATION Rev. 4

Page 12 of 15

© 2017 Dynamic Ratings Specifications and information is subject to change without notice.

Current Transformer Input - CT

Current transformer inputs do not share any pins and are electrically isolated. The electrical characteristics of each are (note - all stated currents are RMS):

Current range: 0mA to 10mA AC

Absolute maximum input current: 15mA

Fundamental frequency range: 47 to 63Hz

Current resolution: 15uA (0.1% of range)

Current accuracy: ± 75uA (±0.5% of range)

Bandwidth: 567Hz (9th harmonic of 63Hz)

Input impedance: 50Ω ± 5%

Sampling rate: 2000 samples per second

Each current transformer input provides protection against over voltage conditions.

Page 13: B100 Series Technical Specification - dynamicratings.com · Fundamental frequency range: 47 to 63Hz Current resolution: 15uA (0.1% of range) Current accuracy: ± 75uA (±0.5% of range)

B100 SERIES TECHNICAL SPECIFICATION Rev. 4

Page 13 of 15

© 2017 Dynamic Ratings Specifications and information is subject to change without notice.

Climatic Conditions

All components are rated for operation at +85°C (+184°F).

System Operating Temperature Range: -40°C to +70°C (-40°F to +158°F)

Mechanical Conditions for Storage and Use

Bm

Stationary vibration, sinusoidal - Displacement amplitude (mm) - Acceleration amplitude (m/s2) - Frequency range (Hz)

3mm @ 2-9Hz 10m/s2 @ 9-200Hz 15m/s2 @ 200-500Hz

Shock - Half-sine duration (ms) - Peak acceleration (m/s2)

11ms @ 100m/s2

Table 2: Mechanical Conditions for Storage and Use

Mounting

The B100 is suitable for external mounting on the transformer, but can be installed inside an equipment cubicle if required. If externally mounted, it is recommended that it is mounted in a height and location that is easily visible and accessible.

Mounting is achieved via four mounting holes (with supplied vibration mounts) on the sides of the housing. The metal ferrules have a hole diameter of 6.4mm (0.25 in.), suited to metric M6 or imperial 1/4-28 fasteners – 316 grade stainless steel is recommended.

Figure 3: Vibration Mount Assembly

Page 14: B100 Series Technical Specification - dynamicratings.com · Fundamental frequency range: 47 to 63Hz Current resolution: 15uA (0.1% of range) Current accuracy: ± 75uA (±0.5% of range)

B100 SERIES TECHNICAL SPECIFICATION Rev. 4

Page 14 of 15

© 2017 Dynamic Ratings Specifications and information is subject to change without notice.

Hardware Standards Compliance IEC 61010-1 Part 1: General Requirements

Product Safety Standards for Measurement, Control, and Laboratory Products

The following versions of 61010-1 are applicable:

International: IEC 61010-1

Europe: EN 61010-1

IEC 60870 Telecontrol Equipment and Systems

IEC 60870-1 General considerations

IEC 60870-2 Operating conditions

IEC 61850

The following sections from IEC 61850:

IEC 61850-3

IEC 61850-5

IEC 61850-6

IEC 61850-7

IEC 61850-8

The B100 product is designed to comply with the relevant sections of the following:

IEC 1613-2003

IEEE Standard Environmental and Testing Requirements for Communications Networking Devices in Electric Power Substations

IEEE C37.90

Standard for Relays and Relay Systems Associated with Electric Power Apparatus

IEEE C57.12.10-1997

American National Standard for Transformers--230 kV and Below 833/958 through 8333/10 417 kVA, Single-Phase, and 750/862 through 60 000/80 000/100 000 kVA, Three-Phase without Load Tap Changing; and 3750/4687 through 60 000/80 000/100 000 kVA with Load Tap Changing--Safety Requirements.

FCC Part 15

EMC Standards for Measurement, Control, and Laboratory Products

Page 15: B100 Series Technical Specification - dynamicratings.com · Fundamental frequency range: 47 to 63Hz Current resolution: 15uA (0.1% of range) Current accuracy: ± 75uA (±0.5% of range)

B100 SERIES TECHNICAL SPECIFICATION Rev. 4

Page 15 of 15

© 2017 Dynamic Ratings Specifications and information is subject to change without notice.

Sales Contacts

To learn more about Dynamic Ratings, a global supplier of sensing, monitoring, controls and communication solutions which improve system reliability, provide maintenance savings and reveal additional capacity of power transformers, circuit breakers, generators, motors, switchgear and cables please contact our sales departments below.

Asia / Africa / Oceania +61 3 9574-7722 [email protected]

Americas +1 262 746-1230 [email protected]

Europe +44 1617 681111 [email protected]