Bentley AutoPLANT V8i (SELECTseries 1) - Installation Procedure IMPORTANT NOTES: In order to successfully install Autodesk and Bentley applications you must be logged in as the local User, with local Administrator rights. Further, to install Bentley AutoPLANT V8i (SELECTseries 1) successfully, AutoCAD 2007 SP2 must first be installed and launched at least once to create the default AutoCAD 2007 profile. Installing Bentley AutoPLANT V8i (SELECTseries 1) You must use all defaults when installing Bentley AutoPLANT V8i (SELECTseries 1). This applies specifically for the type of install: It must be Standalone. The installs will create a C:\BentleyDownloads directory containing installation CAB files. This directory must be left on each client machine. DO NOT remove after installing the applications. The Bentley software must to be installed in the following order: If the machine is to be configured for Bentley ProjectWise you must install the client software before all other Bentley applications. 08.11.07.107_Bentley ProjectWise V8i - Client Setups - pwclt081107107en.exe If not then proceed as follows: 1. 08.11.06.30_1_Bentley AutoPLANT P&ID V8i (SELECTseries 1) - appid08110630en.exe 2. 08.11.06.30_2_Bentley Process & Instrumentation V8i (SELECTseries 1) - prins08110630en.exe 3. 08.11.06.30_3_AutoPLANT Plant Design V8i (SELECTseries 1) - appd08110630en.exe 4. 08.11.02.23 ProStructures V8i AutoCAD (SELECTseries 2) - pstac08110223en.exe 5. 08.11.07.03_Prerequisites for Bentley Desktop Applications - pbda08110703en.exe 6. 08.11.07.171_ProjectWise Navigator V8i (SELECTseries 1) - nav081107171en.exe 7. 08.11.07.171_ProjectWise i-model Composer V8i (SELECTseries 1) - imcom081107171en.exe Once you have successfully installed the applications as above, install the Praxair customizations as detailed in the following pages.

Upload: dirceuromani

Post on 24-Oct-2014

360 views

Category:

Documents


11 download

TRANSCRIPT

Page 1: !AutoPlant v8i

Bentley AutoPLANT V8i (SELECTseries 1) - Installation Procedure

IMPORTANT NOTES: In order to successfully install Autodesk and Bentley applications you must be logged in as the local User, with local Administrator rights. Further, to install Bentley AutoPLANT V8i (SELECTseries 1) successfully, AutoCAD 2007 SP2 must first be installed and launched at least once to create the default AutoCAD 2007 profile.

Installing Bentley AutoPLANT V8i (SELECTseries 1)

You must use all defaults when installing Bentley AutoPLANT V8i (SELECTseries 1). This applies specifically for the type of install: It must be Standalone.

The installs will create a C:\BentleyDownloads directory containing installation CAB files. This directory must be left on each client machine. DO NOT remove after installing the applications.

The Bentley software must to be installed in the following order:

If the machine is to be configured for Bentley ProjectWise you must install the client software before all other Bentley applications.

08.11.07.107_Bentley ProjectWise V8i - Client Setups - pwclt081107107en.exe

If not then proceed as follows:

1. 08.11.06.30_1_Bentley AutoPLANT P&ID V8i (SELECTseries 1) - appid08110630en.exe 2. 08.11.06.30_2_Bentley Process & Instrumentation V8i (SELECTseries 1) - prins08110630en.exe 3. 08.11.06.30_3_AutoPLANT Plant Design V8i (SELECTseries 1) - appd08110630en.exe 4. 08.11.02.23 ProStructures V8i AutoCAD (SELECTseries 2) - pstac08110223en.exe 5. 08.11.07.03_Prerequisites for Bentley Desktop Applications - pbda08110703en.exe 6. 08.11.07.171_ProjectWise Navigator V8i (SELECTseries 1) - nav081107171en.exe 7. 08.11.07.171_ProjectWise i-model Composer V8i (SELECTseries 1) - imcom081107171en.exe

Once you have successfully installed the applications as above, install the Praxair customizations as detailed in the following pages.

Page 2: !AutoPlant v8i

Installing Praxair Customizations for AutoPLANT V8i (SELECTseries 1)

1. The first step is to remove any previously installed ‘Praxair BASE configuration’ files. To do this, run the following batch file:

00_PX-PTC_CUST_Clean_BASE.bat

NOTE: If this is the first time installing customizations on the user’s computer, you may skip this step.

2. The next step is to install the ‘Praxair BASE Customizations’ by running the following executable:

01_PX-PTC_CUST_appd08110630en_v1.0h.exe

At the welcome screen click ‘Next >’.

Click ‘Next >’ again.

Page 3: !AutoPlant v8i

Click ‘Start’ to begin the install.

Click ‘Next >’ one last time.

Click ‘Exit’ to close the installer.

Page 4: !AutoPlant v8i

3. After successfully installing the ‘Praxair BASE Customizations’, set the ‘Drawing Flattener

Settings’ by running the Registry Entries file:

02_PX-PTC_CUST_appd08110630en_v1.0h_Drawing_Flattener.reg

4. For regional installs, run the appropriate executable from the list below:

For Belgium: 03_PX-BEL_CUST_appd08110630en_v1.0h.exe For Brazil: 03_PX-BRA_CUST_appd08110630en_v1.0h.exe For Canada: 03_PX-CAN_CUST_appd08110630en_v1.0h.exe For China: 03_PX-CHN_CUST_appd08110630en_v1.0h.exe For India: 03_PX-IND_CUST_appd08110630en_v1.0h.exe For Mexico: 03_PX-MEX_CUST_appd08110630en_v1.0h.exe

At the welcome screen that appears (as below), click ‘Next >’.

Click ‘Next >’ again.

Page 5: !AutoPlant v8i

Click ‘Start’ to begin the install.

Click ‘Next >’ one last time.

Click ‘Exit’ to close the installer.

Page 6: !AutoPlant v8i

5. Installation is now complete. For detailed information on project administrator procedures and standards, please see the following documents: 01 - Bentley AutoPLANT Plant Design V8i (SELECTseries 1) - Project Administration - New Project Creation

02 - Bentley AutoPLANT Plant Design V8i (SELECTseries 1) - Project Administration - Creating Project Specific VISION Startup Icons

03 - Bentley AutoPLANT Plant Design V8i (SELECTseries 1) - File Naming Convention and Reference Model Hierarchy

04a - Bentley AutoPLANT Plant Design V8i (SELECTseries 1) - Drawing Production - New Document Creation Using Bentley Vision V8i (SELECTseries 1)

04b - Bentley AutoPLANT Plant Design V8i (SELECTseries 1) - Drawing Production - New Document Creation Using ProjectWise Explorer V8i (SELECTseries 1)

05 - Bentley AutoPLANT Plant Design V8i (SELECTseries 1) - Drawing Production - Work Area Setup

06 - Bentley AutoPLANT Plant Design V8i (SELECTseries 1) - Drawing Production - Drawing Flattener

07 - Bentley AutoPLANT Plant Design V8i (SELECTseries 1) - Praxair AutoCAD Color Table

Page 7: !AutoPlant v8i

Bentley AutoPLANT V8i (SELECTseries 1) - Praxair Customizations to the Supports/Topworks Browser

Using the Supports/Topworks Browser

From the Piping pull-down menu select Piping > Supports/Topworks Browser.

From the docked browser tree structure select Supports > Base Supports.

Page 8: !AutoPlant v8i

Two custom support sections are available.

I. Praxair Supports - Cold Box II. Praxair Supports - Warmend

Double-click on PSD-01 U-Bolt Support - Loose (guide). You will be prompted to select the piping component on which you wish to place the support.

Select T to toggle the port you wish to start from then Enter to make the selection.

Enter the distance from the port at which you wish to place the support.

Page 9: !AutoPlant v8i

Chapter 1 Bentley AutoPLANT Plant Design V8i (SELECTseries 1) - Project Administration - New Project Creation

Initial Project Creation New projects can be c two ways:reated in

Distributed Mode: This is a MS Access MDB project database, with individual model MDB files. Distributed mode is intended for small/medium sized projects (only recommended for local C:\ drive temporary project environments) where the user wants to continue to run MS Access for the primary database while retaining the benefits of a managed project. (See page 6 of this chapter)

Central Mode: All data is stored in central project database. It requires a SQL Server database to be created. All Praxair projects are to be created in this mode. (See page 11 of this chapter)

Page 10: !AutoPlant v8i

Getting Started The first step in setting up a project is to create the Local Projects Root folder. This folder is the

top level directory under which individual projects related to the root will reside. You will have more than one Local Projects Root folder with multiple projects defined under each.

Praxair Standard Project File Share Hierarchy File share locations will be set up as follows:

…\PLANT\Generic Product Lines\... …\PLANT\Projects\... …\PLANT\Proposals\... …\PLANT\Specs\...

Projects will further be broken down as follows:

…\PLANT\Projects\SITE_ID\PLANT_TYPE\ PROJ_NAME \...

Where: SITE_ID consists of the EDMS sell location 3-digit country code and a 3-digit site identifier.

Example:

Would be: …\PLANT\Projects\CAN138-Varennes, QB\...

More Examples: …\PLANT\Projects\BRACOS-Cosipa, Brazil\... …\PLANT\Projects\CHNCAO-Caojing, China\... …\PLANT\Projects\DEUHEU-Huerth, Germany\... …\PLANT\Projects\MEXTAM-Tampico, Mexico\... …\PLANT\Projects\USA360-Hawkins, TX\... …\PLANT\Projects\USA978-Riverport, TN\...

Page 11: !AutoPlant v8i

The next level will be:

…\PLANT\Projects\SITE_ID\PLANT_TYPE\ PROJ_NAME \...

Where: PLANT_TYPE refers to the type of plant at the site.

Example: …\PLANT\Projects\CAN044-Montreal_East_QB\ TLA_480\... …\PLANT\Projects\CAN138-Varennes_QB\300_MTON\... …\PLANT\Projects\USA357-Texas_City_2\T-1800\... …\PLANT\Projects\ USA978-Riverport, TN \ PL3XL \...

This folder will act as the Local Projects Root folder. When initially set up as a root using Project Administrator it will contain the following root files:

Access.mdb This file controls Bentley login access/permissions to the projects in the root. at_prods.dbf This file contains REGAPP mappings for Bentley Vision. at_proj.dbf This file logs the PROJ_ID contained in this root (0001, 0002, 0003…)

Note: If the site has multiple identical plant types such as two PL4’s then the root will have to be adjusted to be unique. PL4_1 and PL4_2, etc…

Further: If there are both 2D PID projects and 3D PIPING projects at the plant then the roots are to be adjusted as follows: PL4_2D and PL4_3D, etc…

The last level will be:

…\PLANT\Projects\SITE_ID\PLANT_TYPE\ PROJ_NAME \...

Where: PROJ_NAME is actually the project number.

Example: …\PLANT\Projects\ CAN044-Montreal_East_QB \ TLA_480\10762C\... …\PLANT\Projects\CAN138-Varennes_QB\300_MTON \10133C\... …\PLANT\Projects\USA357-Texas_City_2\T-1800\12711B\...

Below this level is where the Bentley AutoPLANT project file share resides. The folder structure and contents is controlled with Bentley Vision. Unless it is a ProjectWise enabled project, users should only use Bentley Vision to access and modify the project content.

The next section will cover project creation using Bentley Project Administrator V8i.

Page 12: !AutoPlant v8i

Bentley Project Administrator V8i (SELECTseries 1) The installation of Bentley AutoPLANT V8i provides 3 sample projects in the …\Bentley Plant V8i

Projects\... Local Projects Root folder. These are provided as examples only and should not be considered for production.

Adding or Creating a Project Root 1. A new Local Project Root folder may be created or an existing Local Projects Root folder added

by using one of the following methods: • Select File > Add Root from the menu. • Right-click on any folder in the navigation tree, then select Add Root from the context

menu displayed.

In either instance, the Browse For Folder dialog shown below is displayed. Notice when highlighting the SITE-ID folder level of an existing project the OK button is grayed out.

Page 13: !AutoPlant v8i

2. Browse to the PLANT_TYPE folder level which is the actual Local Project Root and notice the OK button is now enabled. Click OK to add this project to your local list of AutoPLANT projects.

3. Click the ‘+’ sign to open the tree structure and see the projects under the Local Projects Root you just added. Highlighting the project will challenge you with the Login to Project dialog.

4. Enter the correct User Name and Password as required for the project root’s Access.mdb file. You can check Save Password if you wish.

Page 14: !AutoPlant v8i

Creating Distributed Mode Projects The Project Administrator provides a wizard driven interface to create new projects. The New

Project Wizard will display a series of dialogs that walk you step-by-step through the process of creating a new project.

For this example we will create a new Local Projects Root folder.

1. Select File > Add Root from the menu. The Browse For Folder dialog will let you browse to new local location to store all AutoPLANT local root folders:

Example: C:\PLANT\Projects\

2. Select Make New Folder and type in a new project root folder.

Example: C:\PLANT\Projects\USA926-Bridgeton, NJ\...

3. Click OK.

Page 15: !AutoPlant v8i

4. You should now have a new empty Local Project Root.

A new project may now be created under the new Local Project Root folder by using one of the following methods:

• Select File > New… from the menu. • Right-click on the root folder in the navigation tree, then select New… from the

context menu displayed.

The New Project - Provider Type dialog will appear. Select Access for ‘Distributed’ mode or SQL Server for ‘Central’ mode projects.

5. Choose Access and click Next>.

Page 16: !AutoPlant v8i

6. At the New Project - Base Template and 3D Settings dialog leave the Base Schematic Template as the default Standard Base Project. Select the 3D Modelling Project Settings. For Praxair projects you must use the correct PX_ prefixed configuration.

Select PX_WARMEND_MMetric

Click Next >.

7. Accept the default New Project - Project Paths. Click Next >.

Page 17: !AutoPlant v8i

8. At the New Project - Details dialog the only required field is the Project Name. The rest are informational fields only. For Praxair projects the Project Name is the Project Number

Example:

Fill in the details and click Finish. You will see the Creating Project… status bar.

Page 18: !AutoPlant v8i

9. When the process is completed you will see Ready in the bottom-left corner. You can also confirm the Mode, Version and Units Type.

Page 19: !AutoPlant v8i

Creating Central Mode Projects The next section covers creating a new Central Mode project and is divided into tasks for

Database Administrators and for Project Administrators (See page 14 of this chapter).

For Database Administrators 1. For ‘Central Mode’ projects the following steps should be taken to configure the SQL

Server for use with AutoPLANT. a. Create a SQL Server login for the AutoPLANT project.

**Note: A new service account should be created for EACH AutoPLANT project!

b. Use the naming convention as described below: i. Username: ap_<ProjectName or Number>_2D (for P&ID projects)

ii. Username: ap_<ProjectName or Number>_3D (for PIPING projects)

e.g. ap_12711B_2D or ap_13593B_3D

iii. Be sure to store password information for future retrieval.

Do NOT check the ‘Enforce password policy’, ‘Enforce password expiration’ and ‘User must change password at next login’. Default database can be left as ‘Master’. Default language can be left as ‘<default>’

c. Create new project database: i. Database name should be in the format ap_<projectnumber>_<2D>/<3D>

e.g. ap_12711B_2D or ap_13593B_3D . ap_12711B_2D or ap_13593B_3D

Page 20: !AutoPlant v8i

ii. Owner ‘Default’

Page 21: !AutoPlant v8i

d. Configure the SQL Server Account created in step 1 to have db_owner rights to the project database.

Page 22: !AutoPlant v8i

For Project Administrators Below is the procedure performed by the Project Administrator once there is confirmation from the

Database Administrator that the database is ready.

1. Highlight the network file share you have setup to be the Local Project Root.

The new project may now be created under the network Local Project Root folder by using one of the following methods:

• Select File > New… from the menu. • Right-click on the root folder in the navigation tree, then select New… from the

context menu displayed.

The New Project - Provider Type dialog will appear.

2. Choose SQL Server and click Next>.

DO NOT check Use Multi Project Mode. DO NOT change the Project Schema Location. Leave it as the default Access database.

Page 23: !AutoPlant v8i

3. At the New Project - Base Template and 3D Settings dialog leave the Base Schematic Template as the default Standard Base Project. Select the 3D Modelling Project Settings. For Praxair projects you must use the correct PX_ prefixed configuration.

Select PX_WARMEND_MMetric

BE SURE to check the Use Central Project Mode box.

Click Next >.

4. Accept the default New Project - Project Paths. Click Next >.

Page 24: !AutoPlant v8i

5. At the New Project - Details dialog the only required field is the Project Name. The rest are informational fields only. For Praxair projects the Project Name is the Project Number

Example:

Fill in the details and click Finish. You will see the Creating Project… status bar.

Page 25: !AutoPlant v8i

6. You will be shown the Data Link Properties dialog.

Enter the correct SQL Server name. Enter the User name: and Password: as provided by the Database Administrator. IMPORTANT: BE SURE to check Allow saving password and BE SURE that you have selected the correct project database.

Click Test Connection. When you see that the Test connection succeeded click OK. Click OK one last time.

Page 26: !AutoPlant v8i

7. When the process is completed you will see Ready in the bottom-left corner.

The project is now created. BEFORE allowing users access to the project, please read and implement Chapter 2:

Bentley AutoPLANT Plant Design V8i (SELECTseries 1) - Project Administration - Creating Project Specific Bentley Vision V8i STARTUP Icons

Page 27: !AutoPlant v8i

Chapter 2 Bentley AutoPLANT Plant Design V8i (SELECTseries 1) - Project Administration - Creating Project Specific Bentley Vision V8i STARTUP Icons

Initial Project Creation

The Project Administrator, upon creation of a new AutoPLANT Plant Design V8i (SELECTseries 1) project from Chapter 1, needs to set up the project specific Bentley Vision V8i startup icon for the users.

Page 28: !AutoPlant v8i

Getting Started Each project comes with the following folder:

…Config\Custom\STARTUP\...

The Custom Files This folder contains the following files:

at.ini at_V8i_XM_Legacy.ini (used by the XM legacy icon) at_prodsV8i.dbf at_prodsV8i_XM_Legacy.DBF (manually copy to project root of XM projects as needed) COPY Me to your desktop COPY Me to your desktop V8i_XM_Legacy EditFieldsDefaults.ini EditFieldsDefaults_EQP.ini (for equipment library projects) Vision.bat Vision_V8i_XM_Legacy.bat (used by the XM legacy icon)

Page 29: !AutoPlant v8i

The Icon Setup Procedure

The AT.ini

1. The first step is to open the at.ini file and search for the [GENERAL] section. Find the APPROJDB line and add the Local Project Root folder path (This path, detailed Chapter 1, is where the access.mdb, at_prodsV8i.dbf and at_proj.dbf files reside):

APPROJDB= C:\PLANT\Projects\USA926-Bridgeton, NJ\

IMPORTANT: If this is not the only project in this root, you must also update the correct PROJ_ID number in the [GENERAL] section:

CurProject=0002

Save and close the at.ini file.

The STARTUP Icon Shortcut

2. The next step is to right-mouse click > Properties on the “COPY Me to your desktop” icon. Paste the STARTUP folder path below into the Target: textbox. Click OK.

Example: C:\PLANT\Projects\USA926-Bridgeton, NJ\14646B\Config\Custom\STARTUP\Vision.bat or C:\PLANT\Projects\USA926-Bridgeton, NJ\14646B\Config\Custom\STARTUP\ Vision_V8i_XM_Legacy.bat

Page 30: !AutoPlant v8i

3. Right-mouse click > Edit on the “COPY Me to your desktop” icon. This will open the Vision.bat file. (For XM Legacy projects edit the “COPY Me to your desktop V8i_XM_Legacy” icon). Replace the following two lines by pasting the STARTUP folder path into the file as shown below:

Replace: C:\Program Files\Bentley\Plant V8i\Config\PX_COLDBOX_MMetric\Custom\STARTUP With: C:\PLANT\Projects\USA926-Bridgeton, NJ\14646B\Config\Custom\STARTUP

4. Next, replace the PROJECT_ROOT path as follows:

Replace: G:\PLANT\Projects\PROJECT_ROOT With: C:\PLANT\Projects\USA926-Bridgeton, NJ

5. You must also replace the PROJECT_DIR path as follows:

Replace: G:\PLANT\Projects\PROJECT_ROOT\PROJECT_DIR With: C:\PLANT\Projects\USA926-Bridgeton, NJ\14646B

Page 31: !AutoPlant v8i

6. Finally, add the PROJECTNAME to the following two lines. Save and close.

Update: C:\Documents and Settings\All Users\Application Data\Bentley\Plant V8i\Config With: C:\Documents and Settings\All Users\Application Data\Bentley\Plant V8i\Config\ 14646B

Distributing the STARTUP Icon

7. Copy and rename the edited icon to your desktop. Distribute to the project team members. When used to start Bentley Vision V8i this will PURGE the local user’s project config folder and launch the user into the project, prompting for a login.

IMPORTANT NOTE: This project specific icon will replace the local instance of the at.ini with each launch thus prompting the user for a login every time. If the user wishes to save the username and password after the initial launch using the project specific icon, use the regular Bentley Vision V8i icon instead.

BEFORE allowing users to start creating project documents have them read Chapters 3 and 4:

Bentley AutoPLANT Plant Design V8i (SELECTseries 1) - File Naming Convention and Reference Model Hierarchy

Bentley AutoPLANT Plant Design V8i (SELECTseries 1) - Drawing Production - New Document Creation

Page 32: !AutoPlant v8i

Chapter 3 Bentley AutoPLANT Plant Design V8i (SELECTseries 1) - File Naming Convention and Reference Model Hierarchy

Due to the introduction of Bentley ProjectWise and the enhanced Bentley Vision feature set, the document management issues of the past pertaining to file share directory structures has been greatly simplified. The Praxair customizations for Bentley AutoPLANT Plant Design V8i (SELECTseries 1) has been stripped down to the following REGAPPS and LOCATION:

AutoPLANT Piping = AT_PIPE > …\documents\ PIPE\...

AutoPLANT Equipment = AT_EQP > …\documents\ EQP\...

AutoPLANT Structural = AT_STRUCT > …\documents\ STRUCT\...

AutoPLANT Raceways = AT_ELECT > …\documents\ ELECT\...

AutoCAD = AT_ACAD > …\documents\ ACAD\...

Design packages will be “Document Grouped” within Vision’s Display Options.

(See the Praxair documentation on Bentley Vision V8i (SELECTseries 1) for instruction on the use of AREA folders in the DOC_REG)

Naming Conventions To facilitate smoother administration of project documents, it is recommended that all models

that get created for each application are clearly and consistently named using an easy to identify description or TAGNUMBER and suffixed with their corresponding REGAPP.

Example: AutoPLANT Piping model

CB_INT_PIPE.dwg

AutoPLANT Equipment model

AV-0200_EQP.dwg (vessel model’s associative primitives and nozzles)

AutoPLANT Structural model

AV-0200_STRUCT.dwg (vessel model’s structural components)

IMPORTANT NOTE: These are examples of root-level models and when referencing each other, are to use the OVERLAY attachment method only.

Page 33: !AutoPlant v8i

Assembly and Sub-Assembly Models Assemblies should be made using the AutoCAD (AT_ACAD) REGAPP. They are to be populated

by root-level application specific REGAPP models and are to use the ATTACHMENT method NOT OVERLAY.

Example: AutoCAD Assemblies

AV-0200_ASSY.dwg (vessel sub-assembly model made up of root-level models)

The table below illustrates the relationship between assembly models and their sub-assembly and/or root-models.

Sub-Assembly References (Attached) AV-0200_ASSY.dwg AV-0200_EQP.dwg AV-0200_STRUCT.dwg AV-0300_ASSY.dwg AV-0300_EQP.dwg AV-0300_STRUCT.dwg AV-0330_ASSY.dwg AV-0330_EQP.dwg AV-0330_STRUCT.dwg

Main Assembly References (Attached) CB_INT_EQP_ASSY.dwg AV-0200_ASSY.dwg AV-0300_ASSY.dwg AV-0330_ASSY.dwg CB_INT_EQP_SUPPORTS_STRUCT.dwg CB_INT_PIPE_ASSY.dwg CB_INT_PIPE.dwg CB_INT_INST_PIPE.dwg CB_INT_PS_STRUCT.dwg

Overall Assembly References (Attached) CB_OVERALL_ASSY.dwg CB_INT_EQP_ASSY.dwg CB_EXT_EQP_ASSY.dwg CB_INT_PIPE_ASSY.dwg CB_EXT_PIPE_ASSY.dwg CB_CASING_PLATE_STRUCT.dwg CB_FRAME_STRUCT.dwg

Page 34: !AutoPlant v8i

Drawing Production When the time comes to generate layout drawings, we launch AutoPLANT Piping and go

through the procedures outlined in the Praxair documentation listed below. At this point when we attach the reference models, it is only the overall model that gets attached. The rest of the models will be automatically brought along and attached. If the project utilizes Work Areas, it is as simple as inserting a pre-generated view into the layout and the references will automatically be attached.

Example:

Layout Drawing References (Attached) B-XXXXXXX.dwg CB_OVERALL_ASSY.dwg

BEFORE allowing users to start creating project documents have them read Chapter 4:

Bentley AutoPLANT Plant Design V8i (SELECTseries 1) - Drawing Production - New Document Creation

Page 35: !AutoPlant v8i

Chapter 4 Bentley AutoPLANT Plant Design V8i (SELECTseries 1) - Drawing Production - New Document Creation

Document Creation Methods In Chapter 3 - File Naming Convention and Reference Model Hierarchy we covered project

structure. Now we are ready to start creating project documents. The following section covers document creation and grouping using two methods:

Non-ProjectWise Enabled: Bentley Vision V8i is used as a document interface to access and create documents.

ProjectWise Enabled: If the project is ProjectWise enabled proceed to the appropriate section in this chapter.

Page 36: !AutoPlant v8i

Getting Started

What Is Bentley Vision V8i Bentley Vision V8i provides an easy-to-use environment to manage critical plant data and

documentation. The tree-like user interface allows you to quickly navigate to a specific component to view operating data and associated documentation. Vision and the P&ID Workgroup share a common relational database model for storage of all plant data including process equipment, lines, valves and instrumentation. Changes made to a P&ID are immediately available through the Vision interface. By sharing a common relational database, errors and data maintenance costs associated with duplicate data are virtually eliminated.

Launch Bentley Vision V8i using the STARTUP icon created in Chapter 2. Once in the project you will see the interface below. The current project is identified along the top bar and in the bottom-left corner.

The Document Display Tab

The left side of the interface is document display tab section. The Praxair Custom Configuration sets the Display Options to enable the use of Document Grouping on the Area value in the DOC_REG.DBF table.

Page 37: !AutoPlant v8i

Creating a New Document Record The New Document dialog enables you to create a new blank document record within the

DOC_REG.DBF table of the current project database (to be used as a place-holder).

To Create a New Document Record 1. Select the Document Tab. 2. Select the appropriate application from the Document Tab navigation tree. Then select

Documents > New… from the pull down menu or right-click on the application to display context menu to select Documents > New… and display the New Document dialog.

3. Enter a name for the document in the File Name field. Entering a description is optional but recommended (the Name and Location fields auto-populate). Then select the appropriate application from the pick-list and press Record Only. This procedure creates a new document record without actually launching the associated application.

Page 38: !AutoPlant v8i

4. Notice the new document record is displayed under an Area Not Defined folder in the navigation tree. This is how Bentley Vision V8i displays a blank Area value within the DOC_REG.DBF table for all newly created entries.

5. To associate the document record with the correct Document Grouping, left-click the Area Property in the Properties tab. For Praxair configurations this pull down [GridLists] menu is pre-populated with Praxair defaults. Make your selection from the pick-list. (NOTE: We will cover how to modify these as needed a little later on.)

Page 39: !AutoPlant v8i

6. To update the navigation tree Document Grouping, highlight the application and select Display > Refresh Tree or you can press function key F5.

7. Each of the applications in the navigation tree will function the same way when adding or creating new documents or document records. ISOGEN documents, when generated will also register in the DOC_REG and also show up under an Area Not Defined folder.

Page 40: !AutoPlant v8i

Creating a New Document from Vision The New Document dialog also enables you to create a new blank document to add to the

current project.

To Create a New Document from Vision 1. Select the Document Tab. 2. Select the appropriate application from the Document Tab navigation tree. Then select

Documents > New… from the pull down menu or right-click on the application to display context menu to select Documents > New… and display the New Document dialog.

3. Like before, enter a name for the document in the File Name field. Then select the appropriate application from the pick-list, but this time press Create. This procedure creates a new document and launches the associated application.

Page 41: !AutoPlant v8i

4. After saving and closing AutoCAD notice the new document record is displayed under an Area Not Defined folder in the navigation tree.

5. Like before associate the document record with the correct Document Grouping, by left-clicking the Area Property in the Properties tab. Make your selection then update the navigation tree Document Grouping by highlighting the application and selecting Display > Refresh Tree or by pressing function key F5.

Page 42: !AutoPlant v8i

Chapter 5 Bentley AutoPLANT Plant Design V8i (SELECTseries 1) - Drawing Production - Work Area Setup

Work Area Creation The Project Administrator, upon creation of a new AutoPLANT Plant Design V8i (SELECTseries 1)

project from Chapter 1, needs to set up the project specific Bentley Vision V8i startup icon for the users.

Page 43: !AutoPlant v8i

Getting Started 1. To setup a Work Area in AutoPLANT Plant Design V8i you must have a Piping session open.

Using the pull down menu:

Piping > Drawing Production > Work Area Setup

You will see the Work Area Setup dialog box. Select Open…

2. You will then see a list of Praxair pre-populated work areas contained in the current project. Select the one you wish to create and click OK.

Page 44: !AutoPlant v8i

3. Next, we want to build a list of Reference Drawings by clicking Add… and then OK.

4. At the Project Documents Selection dialog box highlight the location you wish to attach and click the arrow button shown.

Page 45: !AutoPlant v8i

5. With the documents now selected click OK.

6. Verify the Membership Status. Normally, if the current drawing is an assembly model you would set the status to Guest. Select Done and if prompted to save changes select Yes.

Page 46: !AutoPlant v8i

Chapter 6 Bentley AutoPLANT Plant Design V8i (SELECTseries 1) - Drawing Production - Drawing Flattener

Drawing Flattener This is a Bentley AutoPLANT V8i utility that generates a flat AutoCAD file from a source file’s

layout view. It must contain at least one MVIEW viewport of the 3D model. Much like how ISOGEN generates an isometric drawing, this output file is an unintelligent snapshot of the source file that shows visible and hidden edges on separate layers.

Page 47: !AutoPlant v8i

Getting Started 1. Drawing Flattener V8i is launched from the Start menu.

Start > All Programs > Bentley > Plant V8i > Tools > Drawing Flattener

Or from:

C:\Documents and Settings\All Users\Start Menu\Programs\Bentley\Plant V8i\Tools

2. You will see the Bentley AutoPLANT Drawing Flattener V8i (SELECTseries 1) interface below:

Page 48: !AutoPlant v8i

3. You can add files to the list from either the File pull down menu or from the toolbar button menu.

4. Browse to the folder where the layout drawings that you wish to flatten reside. Make your selection and click Open.

Page 49: !AutoPlant v8i

5. AutoCAD will open and close a few times to build the selection set. When it is ready you will see an open empty AutoCAD session and your selection in the list. You can start flattening from the pull down menu File > Flatten or from the toolbar button menu. If you have a previously flattened file you will be prompted to overwrite it. Click Yes.

6. Depending on the complexity of the source file, the procedure can take anywhere from as short as 2-3 minutes or as long as 10-15 minutes. It all depends on how many viewports the source file contains and how many references models are being processed. It is recommended you not work on other tasks while the procedure runs. You may inadvertently interrupt the flattening process.

Page 50: !AutoPlant v8i

7. When the procedure has successfully completed you will see a green check next to the file. You can

Page 51: !AutoPlant v8i

Bentley AutoPLANT V8i (SELECTseries 1) - Praxair AutoCAD Color Table

IMPORTANT NOTES: Below is a list of the 255 AutoCAD color palette and the commonly used Praxair layers associated with each color. Note that we have provided unique pipe service colors to help differentiate and clarify model review. Within the AutoPLANT Piping application we now set the piping colors to “BYLAYER” instead of the old “BYSIZE” setting.

Colors 1 to 255 Usage Color No. Color Lineweight mm Inches 1 Red 0.25 0.010 CASING QUADRANT_2 2 Yellow 0.50 0.020 3 Green 0.35 0.014 4 Cyan 0.50 0.020 5 Blue 0.13 0.005 6 Magenta 0.18 0.007 7 White/Black 0.25 0.010 8 Grey 0.13 0.005 9 Grey 0.18 0.007 10 Red 0.50 0.020 11 Pink 0.50 0.020 HYDROGEN1 12 Red 0.50 0.020 HYDROGEN2 13 Pink 0.50 0.020 HYDROGEN3 14 Red 0.50 0.020 HYDROGEN4 15 Pink 0.50 0.020 HYDROGEN5 16 Red 0.50 0.020 HYDROGEN6 17 0.25 0.010 18 0.25 0.010 19 0.25 0.010 20 0.25 0.010 21 0.50 0.020 OXYGEN1 22 0.50 0.020 OXYGEN2 23 0.50 0.020 OXYGEN3 24 0.50 0.020 OXYGEN4 25 0.50 0.020 OXYGEN5 26 0.50 0.020 OXYGEN6 27 0.25 0.010 28 0.25 0.010 29 0.25 0.010 30 Orange 0.25 0.010 STEEL, CASING QUADRANT_3 31 0.50 0.020 KETTLE1 32 Orange 0.50 0.020 KETTLE2 33 0.50 0.020 KETTLE3 34 Orange 0.50 0.020 KETTLE4

Page 52: !AutoPlant v8i

35 0.50 0.020 KETTLE5 36 Orange 0.50 0.020 KETTLE6 37 0.25 0.010 38 0.25 0.010 39 0.25 0.010 40 0.25 0.010 41 0.18 0.007 TEXT-THIN 42 0.70 0.028 43 0.13 0.005 FOUNDATION 44 0.25 0.010 45 0.25 0.010 46 0.25 0.010 47 0.25 0.010 48 0.25 0.010 49 0.25 0.010 50 Yellow 0.25 0.010 TEXT-MEDIUM, CASING QUADRANT_1 51 0.50 0.020 GAS1 52 Yellow 0.50 0.020 GAS2 53 0.50 0.020 GAS3 54 Yellow 0.50 0.020 GAS4 55 0.50 0.020 GAS5 56 Yellow 0.50 0.020 GAS6 57 0.25 0.010 58 0.25 0.010 59 0.25 0.010 60 0.25 0.010 61 0.25 0.010 62 0.25 0.010 63 0.35 0.014 STEEL_PIPE_SUPPORT 64 0.18 0.007 STEEL_GRATING 65 0.25 0.010 66 0.25 0.010 67 0.25 0.010 68 0.25 0.010 69 0.25 0.010 70 0.25 0.010 71 0.50 0.020 XENON1 72 0.50 0.020 XENON2 73 0.50 0.020 XENON3 74 0.50 0.020 XENON4 75 0.50 0.020 XENON5 76 0.50 0.020 XENON6 77 0.25 0.010 78 0.25 0.010 79 0.25 0.010 80 0.25 0.010 81 0.25 0.010 82 0.25 0.010

Page 53: !AutoPlant v8i

83 0.25 0.010 84 0.25 0.010 85 0.25 0.010 86 0.25 0.010 87 0.25 0.010 88 0.25 0.010 89 0.25 0.010 90 Green 0.25 0.010 91 0.25 0.010 92 Green 0.25 0.010 93 0.25 0.010 94 Green 0.25 0.010 95 0.25 0.010 96 Green 0.25 0.010 97 0.25 0.010 98 0.25 0.010 99 0.25 0.010 100 0.35 0.014 EQUIP 101 0.50 0.020 NITROGEN1 102 0.50 0.020 NITROGEN2 103 0.50 0.020 NITROGEN3 104 0.50 0.020 NITROGEN4 105 0.50 0.020 NITROGEN5 106 0.50 0.020 NITROGEN6 107 0.25 0.010 108 0.25 0.010 109 0.25 0.010 110 0.25 0.010 111 0.13 0.005 BLDG 112 0.70 0.028 REVISION 113 0.25 0.010 114 0.25 0.010 115 0.25 0.010 116 0.25 0.010 117 0.25 0.010 118 0.25 0.010 119 0.25 0.010 120 Cyan 0.25 0.010 121 0.18 0.007 FOUND_SCUPPERS 122 0.25 0.010 EL_TRAY 123 0.35 0.014 ROADWAY 124 0.25 0.010 EXISTING (FOUNDATION, STEEL) 125 0.25 0.010 ROADWAY_EXISTING 126 0.25 0.010 127 0.25 0.010 128 0.25 0.010 129 0.25 0.010 130 Cyan 0.25 0.010 CASING QUADRANT_4

Page 54: !AutoPlant v8i

131 0.50 0.020 WATER1 132 Cyan 0.25 0.020 WATER2 133 0.25 0.020 WATER3 134 Cyan 0.25 0.020 WATER4 135 0.25 0.020 WATER5 136 Cyan 0.25 0.020 WATER6 137 0.25 0.010 138 0.25 0.010 139 0.25 0.010 140 0.25 0.010 141 0.25 0.010 EL_DUCT_BANK 142 0.25 0.010 EQUIP_BUNDLEPULL 143 0.35 0.014 BORDER 144 0.25 0.010 145 0.25 0.010 146 0.25 0.010 147 0.25 0.010 148 0.25 0.010 149 0.25 0.010 150 0.25 0.010 151 0.50 0.020 AIR1 152 0.50 0.020 AIR2 153 0.50 0.020 AIR3 154 0.50 0.020 AIR4 155 0.50 0.020 AIR5 156 0.50 0.020 AIR6 157 0.25 0.010 158 0.25 0.010 159 0.25 0.010 160 0.25 0.010 161 0.50 0.020 CO2_1 162 0.25 0.020 CO2_2 163 0.25 0.020 CO2_3 164 0.25 0.020 CO2_4 165 0.25 0.020 CO2_5 166 0.25 0.020 CO2_6 167 0.25 0.010 168 0.25 0.010 169 0.25 0.010 170 Blue 0.25 0.010 171 0.13 0.005 CENTERLINES, DIMENSIONS 172 Blue 0.13 0.005 CENTERLINES (EL_TRAY, FOUNDATION, STEEL) 173 0.25 0.010 174 Blue 0.25 0.010 175 0.25 0.010 176 Blue 0.25 0.010 177 0.25 0.010 178 0.25 0.010

Page 55: !AutoPlant v8i

179 0.25 0.010 180 0.25 0.010 181 0.25 0.010 182 0.25 0.010 183 0.25 0.010 184 0.25 0.010 185 0.25 0.010 186 0.25 0.010 187 0.25 0.010 188 0.25 0.010 189 0.25 0.010 190 0.25 0.010 191 0.50 0.020 ARGON1 192 0.50 0.020 ARGON2 193 0.50 0.020 ARGON3 194 0.50 0.020 ARGON4 195 0.50 0.020 ARGON5 196 0.50 0.020 ARGON6 197 0.25 0.010 198 0.25 0.010 199 0.25 0.010 200 0.25 0.010 201 0.25 0.010 202 1.00 0.039 MATCHLINES 203 0.13 0.005 GRIDLINES 204 0.25 0.010 205 0.25 0.010 206 0.25 0.010 207 0.25 0.010 208 0.25 0.010 209 0.25 0.010 210 Magenta 0.25 0.010 211 0.50 0.020 TEXT_HEAVY 212 Magenta 0.25 0.010 213 0.25 0.010 214 Magenta 0.25 0.010 215 0.25 0.010 216 Magenta 0.25 0.010 217 0.25 0.010 218 0.25 0.010 219 0.25 0.010 220 0.25 0.010 221 0.50 0.020 CHEMICAL1 222 0.50 0.020 CHEMICAL2 223 0.50 0.020 CHEMICAL3 224 0.50 0.020 CHEMICAL4 225 0.50 0.020 CHEMICAL5 226 0.50 0.020 CHEMICAL6

Page 56: !AutoPlant v8i

227 0.25 0.010 228 0.25 0.010 229 0.25 0.010 230 0.25 0.010 231 0.35 0.014 TEXT_BUBBLE 232 0.25 0.010 233 0.25 0.010 234 0.25 0.010 235 0.25 0.010 236 0.25 0.010 237 0.25 0.010 238 0.25 0.010 239 0.25 0.010 240 0.18 0.007 FOUND_ANCHOR_BOLTS 241 0.25 0.010 STEEL_HANDRAIL, STEEL_LADDER 242 0.25 0.010 243 0.25 0.010 244 0.25 0.010 245 0.25 0.010 246 0.25 0.010 247 0.25 0.010 248 0.25 0.010 249 0.25 0.010 250 0.25 0.010 251 Grey 0.25 0.010 252 Grey 0.50 0.020 CONDENSATE 253 Grey 0.50 0.020 STEAM 254 Grey 0.18 0.007 EL_INSTRUMENT 255 White 0.25 0.010

Page 57: !AutoPlant v8i

Removing AutoPlant XM

After removing all AutoPlant XM applications (including ProjectWise) it is necessary to remove all the Bentley folders and registry entries from the user’s machine before installing AutoPlant V8i. Make sure the user has admin privileges on the machine. Also, make sure the user has checked the option ‘Show Hidden Files and Folders’ in the View tab in Folder Options in Windows Explorer.

Note: It is not necessary to remove AutoCAD before installing V8i.

Remove Bentley Program folders Remove all of the following folders

1. C:\Documents and Settings\All Users\Application Data\Bentley 2. C:\Documents and Settings\(User Name)\Application Data\Bentley 3. C:\Documents and Settings\(User Name)\Local Settings\Application Data\Bentley 4. C:\Program Files\Bentley 5. C:\Program Files\Common Files\Bentley Shared

Remove Bentley Registry Entries Remove the following registry entries