Mayo Renewable Power IPPC Licence Application Attachment No. A
A - 1 of 4 February 2012
ATTACHMENT No. A
NON- TECHNICAL SUMMARY
TABLE OF CONTENTS
A.1. Installation and its Activities .................................................................................. 2
A.2. Raw and Auxilliary Materials ................................................................................ 2
A.3. Sources of Emissions from the Installation ........................................................... 2
A.4. Emissions to Waters ................................................................................................ 3
A.5. Environmental Conditions of the Site of the Installation .................................... 3
A.6. Nature and Quantities of Forseeable Emissions from the Installation ............... 3
A.7. Technology and Techniques for Preventing and Reducing Emissions ............... 4
A.8. Measures for the prevention and Recovery of Waste .......................................... 4
A.9. Further Measures to Comply with General Basic Principles of the Operator .. 4
A.10. Normal Operating Hours ....................................................................................... 4
For
insp
ectio
n pur
pose
s only
.
Conse
nt of
copy
right
owne
r req
uired
for a
ny ot
her u
se.
EPA Export 11-02-2012:04:06:03
Mayo Renewable Power IPPC Licence Application Attachment No. A
A - 2 of 4 February 2012
A.1. Installation and its Activities
Mayo Renewable Power Limited is proposing to construct and own a new nominal 50 MWe Combined Heat and Power (CHP) Plant at the Killala Business Park, Killala, County Mayo. The site location is shown in Figure A.1. The long term aim of this proposal is to provide an extremely high efficiency CHP plant. The predominant fuel for the project will be wood biomass (renewable) with oil making up the remainder at a minimum of 4% of the total fuel amount. The plant will produce significantly lower CO2 emissions than a modern gas-fired power station. The key structures of the Mayo Renewable Power Ltd development will include the following: Boiler House and main stack Turbine House Water Treatment Plant Fire fighting pump house Fuel Tanks Auxiliary Transformer Generator Step-Up Transformer Back-up generator
The site layout and activity maps are shown in Figures A.2-A.4.
A.2. Raw and Auxilliary Materials
Mayo Renewable Power Ltd will generate steam use a fuel mix of mesquite, spruce, willow and 4% fuel oil to fuel a stoker grate boiler. Biofuel will be delivered by conveyor from the neighbouring Dalkia Ltd biofuel production facility. 344 m3 Type 2 fuel oil will be stored in tanks on the site. Key processes taking place on site are power generation in the turbine building, incoming raw water treatment, wastewater treatment, re-use of flue gas heat using a condensing economiser and storage of ash prior to re-use off site. Warm water will be delivered from the plant to the neighbouring Dalkia Ltd biofuel production facility and boiler ash will be sold in a commercial arrangement for use as forestry fertiliser.
A.3. Sources of Emissions from the Installation
A.3.1 Sources of Atmospheric Emissions
The main boiler emission point from the facility is the boiler stack. Vents and valves in the plant are considered minor emission points.
A.3.2 Sources of Water Emissions
Surface water run-off from roofs and roadways within the site will be discharged to a private sewer on a neighbouring biofuel facility site.
For
insp
ectio
n pur
pose
s only
.
Conse
nt of
copy
right
owne
r req
uired
for a
ny ot
her u
se.
EPA Export 11-02-2012:04:06:03
Mayo Renewable Power IPPC Licence Application Attachment No. A
A - 3 of 4 February 2012
A.3.3 Noise Emissions
Baseline noise monitoring was undertaken for the facility, along with modelling of noise impacts at the nearest sensitive receptors. Cladding installed in the boiler and turbine building will abate noise emissions from internal equipment. It is not anticipated there will be any discernable noise impact at sensitive receptors associated with the Mayo Renewable Power facility.
A.4. Emissions to Waters
Surface water will pass through a private sewer, silt trap, petrol interceptor and detention basin prior to discharge to the Mullafarry Stream. Process waste water will be discharged without treatment to a storage reservoir and for dust supression at a woodchip pile contained within the neighbouring Fuel Processing Facility. No emissions to surface water or municipal sewer connection are planned.
A.5.
A.6. Environmental Conditions of the Site of the Installation
There are no ecological designated areas in the vicinity of the Mayo Renewable Power Ltd site. The activity is not carried out on any natural habitats designated in accordance with legislation, or located such that it is liable to have an adverse effect on such natural habitats.
A.7. Nature and Quantities of Forseeable Emissions from the Installation
The emissions from the Mayo Renewable Power Ltd facility will not result in significant environmental pollution as required by relevant legislation.
A.7.1 Air Emissions
Emissions from the boiler stack were modelled using a screening model to determine the atmospheric impact on the surrounding area. Predicted concentrations of all pollutants reach a maximum of 36% of the air quality standards. This impact will not have a significant impact on the atmospheric environment.
A.7.2 Noise Emissions
Baseline noise monitoring was undertaken for this application, along with modelling of noise impacts at the nearest sensitive receptors. Cladding installed in the boiler and turbine building will abate noise emissions from internal equipment. It is not anticipated there will be any discernable noise impact at sensitive receptors associated with the Mayo Renewable Power facility.
A.7.3 Water Emissions
For
insp
ectio
n pur
pose
s only
.
Conse
nt of
copy
right
owne
r req
uired
for a
ny ot
her u
se.
EPA Export 11-02-2012:04:06:03
Mayo Renewable Power IPPC Licence Application Attachment No. A
A - 4 of 4 February 2012
There will be no emissions to surface waters or public sewer from the proposed development. Surface water will be discharged to a private sewer in a neighbouring biofuel facility for treatment. Process water will be treated prior to delivery through a private sewer for treatment in the neighbouring biofuel facility. Sanitary wastewater will be delivered by private sewer for treatment in a package treatment plant and a percolation area.
A.8. Technology and Techniques for Preventing and Reducing Emissions
Mayo Renewable Power Ltd will make a considerable investment in BAT based technologies. The proposed Selective Non- Catalytic Reduction NOx abatement system complies with European Standards for Best Available Techniques.
A.9. Measures for the prevention and Recovery of Waste
All wastes arising at the Mayo Renewable Power Ltd facility will be removed by authorised waste collection permit holders. Wastes arising at the plant from power generation, maintenance and other typical sources will be classified in consultation with waste collectors, the European Waste Catalogue and relevant waste legislation. Hazardous waste streams will be collected, segregated and transported off-site by specialist waste management companies for appropriate treatment, recycling and/or disposal. Mayo Renewable Power Ltd endeavours to minimise and recover wastes where possible. Where this is not feasible collection recycling or disposal of waste is undertaken using authorised waste collection permit holders and licensed waste facilities to minimise any environmental impact.
A.10. Further Measures to Comply with General Basic Principles of the Operator
The site will be operated in accordance with the Dalkia Environmental Manual and an ISO 14001: 2004 accredited Environmental Management System (EMS).
A.11. Normal Operating Hours
The proposed development will operate 24 hours per day, 7 days per week for circa 8,100 hours per annum. There will be a total of 19 people employed by Mayo Renewable Power when the plant becomes operational. Staff members will work over three shifts as follows:
06:00 – 14:00 14:00 – 22:00 22:00 – 06:00
For
insp
ectio
n pur
pose
s only
.
Conse
nt of
copy
right
owne
r req
uired
for a
ny ot
her u
se.
EPA Export 11-02-2012:04:06:03
Site:
E = 120594
N = 327865
Job No
Drawing Status
Discipline
Scale at A4
Drawing No Issue
Drawing Title
Job Title
Do not scale © Arup
A4
Date
February 2012
Ordnance Survey Ireland Licence No. EN0002812 © Government of Ireland
000 PL1327873-70
1:50,000
Planning
Environmental
Figure: A1
Site Location
Mayo Renewable Power Ltd.
IPPC Licence Application
Arup, 50 Ringsend Road
Dublin 4
Tel +353(0)1 233 4455 Fax +353(0)1 668 3169
www.arup.ie
N
1000 2000 Metres0
Scale 1:50,000
500
Created using CADplot http://www.oasys-software.com/cadplot/
For
insp
ectio
n pur
pose
s only
.
Conse
nt of
copy
right
owne
r req
uired
for a
ny ot
her u
se.
EPA Export 11-02-2012:04:06:03
A3 A
1
B C D E F G
2
3
4
5
6
Job No
Drawing Status
Discipline
Scale at A3
Drawing No Issue
Drawing Title
Job Title
Client
Issue Date By Chkd Appd
Do not scale © Arup
Ordnance Survey Ireland Licence No. EN0002812 © Government of Ireland
Date
February 2012
000 PL1327873-70
1:1,000
Planning
Environmental
Figure: A2
Site Layout
IPPC Licence Application
Mayo Renewable Power Ltd.
Killala
Co. Mayo
\\dubnts03\D
ublin_Jobs\D
7800-D
7899\D
7873\4. Internal P
roject D
ata\4-02 D
raw
ings\4-02-6 E
nvironm
ental\IP
PC
\A
-02___S
ite Layout.dw
g 3 F
eb 2012 12:34:42
Arup, 50 Ringsend Road
Dublin 2
Tel +353(0)1 233 4455 Fax +353(0)1 668 3169
www.arup.ie
50 Metres2050
Scale 1:1000
10
N
Notes:
1. All coordinates relative to Irish national grid.
Created using CADplot http://www.oasys-software.com/cadplot/
For
insp
ectio
n pur
pose
s only
.
Conse
nt of
copy
right
owne
r req
uired
for a
ny ot
her u
se.
EPA Export 11-02-2012:04:06:03
03
02
0110
07
08
09
04
06
05
03
11
A3 A
1
B C D E F G
2
3
4
5
6
Job No
Drawing Status
Discipline
Scale at A3
Drawing No Issue
Drawing Title
Job Title
Client
Issue Date By Chkd Appd
Do not scale © Arup
Ordnance Survey Ireland Licence No. EN0002812 © Government of Ireland
Date
February 2012
000 PL1327873-70
1:1,000
Planning
Environmental
Figure: A3
Activity Map
IPPC Licence Application
Mayo Renewable Power Ltd.
Killala
Co. Mayo
J:\D
7800-D
7899\D
7873\4. Internal P
roject D
ata\4-02 D
raw
ings\4-02-6 E
nvironm
ental\IP
PC
\A
-03___A
ctivity M
ap.dw
g 3 F
eb 2012 10:43:08
Arup, 50 Ringsend Road
Dublin 2
Tel +353(0)1 233 4455 Fax +353(0)1 668 3169
www.arup.ie
50 Metres2050
Scale 1:1000
10
N
Legend:
1. Turbine House
2. Boiler House
3. Water Treatment Plant
4. Main Stack
5. Fire Water Storage Tank
6. Bunded Fuel Tanks
7. Generator Step-Up Transformer
8. Auxiliary Transformer
9. Back-Up Generator
10. Demineralised Water Storage
Tank
11. Urea Tank
Notes:
1. All coordinates relative to Irish national grid.
Created using CADplot http://www.oasys-software.com/cadplot/
For
insp
ectio
n pur
pose
s only
.
Conse
nt of
copy
right
owne
r req
uired
for a
ny ot
her u
se.
EPA Export 11-02-2012:04:06:03
01
02
03
04
05
06
090807
10
121311
15
14
17
16
18
19
20
21
22
23
24
25
26 27
34
3637
31
35
35
30
29
28
32
33
A3 A
1
B C D E F G
2
3
4
5
6
Job No
Drawing Status
Discipline
Scale at A3
Drawing No Issue
Drawing Title
Job Title
Client
Issue Date By Chkd Appd
Do not scale © Arup
Ordnance Survey Ireland Licence No. EN0002812 © Government of Ireland
Date
February 2012
000 PL1327873-70
NTS
Planning
Environmental
Figure: A4
Activity Within Buildings
IPPC Licence Application
Mayo Renewable Power Ltd.
Killala
Co. Mayo
J:\D
7800-D
7899\D
7873\4. Internal P
roject D
ata\4-02 D
raw
ings\4-02-6 E
nvironm
ental\IP
PC
\A
-04___A
ctivity M
ap B
ldg.dw
g 3 F
eb 2012 10:42:56
Arup, 50 Ringsend Road
Dublin 2
Tel +353(0)1 233 4455 Fax +353(0)1 668 3169
www.arup.ie
N
Boiler House:
28. Electrostatic Precipitator
29. Steam Drum
30. ID Fan
31. Flue Gas Condenser
32. Main Stack
33. Boiler
34. Econimiser
35. Stairwell
36. SNCR
37. Air Preheater
Turbine House:
1. Control Room
2. Conference Room
3. Operations Office
4. Staff Welfare
5. Maintenance Shop
6. Store Room
7. Aux Cooling Water Surge Tank
8. Aux Cooling Water Pump
9. Aux Cooling Water Heat Exchanger
10. Lubrication Oil Coolers
11. Generator
12. Steam Turbine
13. Condenser
14. Gland Condenser
15. Condensate Pumps
16. Air Receiver
17. Filter Dryer Skid
18. Air Compressor
19. Boiler Emergency Cooling Pump A
20. HP. FW. HTR. No 1 - 4
21. PT1 GSU Transformer
22. 13.8 kV Switchgear
23. PT2 Auxiliary Transformer
24. Stand-by Diesel Generator
25. 6.6 kV Switchgear
26. PT3 Auxiliary Transformer
27. 400V Switchgear
Created using CADplot http://www.oasys-software.com/cadplot/