ATTACHMENT A DEMONSTRATION OF THE CONFORMANCE TO THE IOCFR50.46 ACCEPTANCE CRITERIA FOR THE LARGE BREAK LOSS-OF-COOLANT ACCIDENT FOR THE H. B. ROBINSON UNIT 2 NUCLEAR POWER PLANT WITH EXXON NUCLEAR COMPANY FUEL WESTINGHOUSE ELECTRIC CORPORATION NUCLEAR TECHNOLOGY DIVISION NUCLEAR SAFETY DEPARTMENT SAFEGUARDS ENGINEERING AND DEVELOPMENT NOVEMBER 1985 PDR ADOCK PDR (3015BAT/ccc)

Upload: others

Post on 28-Feb-2022

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: ATTACHMENT A DEMONSTRATION CONFORMANCE

ATTACHMENT A

DEMONSTRATION OF THE CONFORMANCE

TO THE IOCFR50.46 ACCEPTANCE CRITERIA

FOR THE LARGE BREAK LOSS-OF-COOLANT ACCIDENT

FOR THE

H. B. ROBINSON UNIT 2 NUCLEAR POWER PLANT

WITH EXXON NUCLEAR COMPANY FUEL

WESTINGHOUSE ELECTRIC CORPORATION

NUCLEAR TECHNOLOGY DIVISION

NUCLEAR SAFETY DEPARTMENT

SAFEGUARDS ENGINEERING AND DEVELOPMENT

NOVEMBER 1985

PDR ADOCK PDR (3015BAT/ccc)

Page 2: ATTACHMENT A DEMONSTRATION CONFORMANCE

ATTACHMENT

DEMONSTRATION OF THE CONFORMANCE TO THE 1OCFR50.46 ACCEPTANCE CRITERIA

FOR THE LARGE BREAK LOSS-OF-COOLANT ACCIDENT FOR THE

H. B. ROBINSON UNIT 2 NUCLEAR POWER PLANT WITH EXXON NUCLEAR COMPANY FUEL

I. INTRODUCTION

A safety evaluation was performed to justify the resumption of operation of the H. B. Robinson Unit 2 nuclear power plant with Exxon fuel to 100% of the licensed core power level of 2300 MWt. The evaluation was performed using the Westinghouse 1981 Evaluation Model with BART for a double-ended guillotine break of the cold leg with a discharge coefficient of 0.4. The results of the analysis demonstrate conformance with the requirements of the 10CFR50.46 acceptance criteria.

II. METHOD OF ANALYSIS

As a technical basis for the safety evaluation, an analysis of a postulated large break LOCA was performed for H. B. Robinson Unit 2 using the 1981 Evaluation Model with BART. In order to perform the analysis on an expedited basis, the analysis was performed using an input model that was previously assembled for evaluation of Florida Power and Light's Turkey Point Unit 3 nuclear power plant as a basis. The H. B. Robinson and Turkey Point Unit 3 design parameters are compared in Table 1. This comparison indicates the similarities of the physical layout and characteristics of the two plants' Nuclear Steam Supply Systems (NSSS), and that the control volume representation of Turkey Point's NSSS represents the H. B. Robinson NSSS, when modified with the following plant specific items. The input was modified to incorporate H. B. Robinson's power level, primary system operating conditions, Emergency Core Cooling System (ECCS), steam generator secondary side pressure and steam flow inputs, and fuel. The information used to model the fuel was supplied by the Exxon Nuclear Company.

The mathematical model used was the Westinghouse 1981 Evaluation Model with BART, which has been approved for use by the NRC as meeting the requirements of an acceptable ECCS Evaluation Model as presented in Appendix K of 10CFR50. This evaluation model is comprised of the SATAN-VI, WREFLOOD, COCO, BART and LOCTA-IV codes, which are described in References 1-7. These codes assess the core heat transfer and determine if the core remains amenable to cooling throughout and subsequent to the blowdown, refill, and reflood phases of the LOCA. The SATAN-VI code is employed for the thermal-hydraulic transient during blowdown, while the WREFLOOD code computes this transient during refill and reflood. The COCO code is used for the complete containment pressure history for dry containments. Reflood thermal-hydraulic conditions are supplied to the BART code which performs the heat transfer calculation for the average fuel channel in the hot assembly using a mechanistic core heat transfer model. This information is then used by LOCTA-IV to calculate the fuel clad temperature and metal-water reaction of the hottest rod in the core. Additional information on the Westinghouse Evaluation Model and methodology is in References 8-13.

(3015BAT/ccc)

Page 3: ATTACHMENT A DEMONSTRATION CONFORMANCE

Based on past Westinghouse analyses for both plants, a double-ended guillotine break of the cold leg with a discharge coefficient of 0.4 was selected for the evaluation. This was the limiting break size not only for the last Westinghouse analysis performed for H. B. Robinson, which used the October 1975 Evaluation Model, but was also limiting for the Turkey Point Unit 3 analyses, including analyses using the October 1975 Evaluation Model and the 1981 Evaluation Model with BART.

The analysis was performed assuming a chopped cosine power shape, which peaked at the six foot elevation. This power shape has been determined to be the limiting power shape for large break LOCA analyses using Westinghouse Evaluation Models (Reference I1). Recent sensitivity studies have demonstrated that the chopped cosine power shape is also limiting for large break LOCA analysis for Exxon fuel using Westinghouse Evaluation Models. These studies have shown that the calculated peak cladding temperature predicted for the Exxon fuel using Westinghouse methodology is over one hundred degrees higher for a chopped cosine power shape than it is for power shapes that are skewed toward the top of the core. While these studies were not performed for a 3-loop plant, there is no reason to believe that H. B. Robinson Unit 2 would perform any differently.

III. RESULTS

Table 2 presents the peak clad temperature and hot spot metal reaction for the Cd = 0.4 break size. The calculated PCT was 21990 F occurring at 108 seconds at an elevation of 6.0 feet relative to the bottom of the active core. The maximum local metal-water reaction was 7.09 percent, which is well below the embrittlement limit of 17 percent, as required by I0CFR50.46. The analysis was performed at 102 percent of the licensed core power of 2300 MWt at the total peaking factor of 2.32 and enthalpy rise factor of 1.65. Table 3 presents the time sequence of events for the large break LOCA. Figures 1-16 present the transients for the principal parameters for the break analyzed.

IV. CONCLUSIONS

This analysis demonstrates that the H. B. Robinson Unit 2 nuclear iower plant with Exxon fuel operating at 100% power, with the 2.32 F T and 1.65 F limits, conforms to the Acceptance Criteria as presented in I0CFR50.46Rhen analyzedrwith the Westinghouse 1981 Evaluation Model with BART. That is:

1. The calculated peak fuel element clad temperature provides margin to the requirement of 2200oF, based on an F QT value of 2.32.

2. The amount of fuel element cladding that reacts chemically with water or steam does not exceed 1 percent of the total amount of Zircaloy in the reactor.

3. The clad temperature transient is terminated at a time when the core geometry is still amenable to cooling. The clad oxidation limits of 17% are not exceeded during or after quenching.

4. The core temperature is reduced and decay heat is removed for an extended period of time, as required by the long-lived radioactivity remaining in the core.

(301 5BAT/ccc)

Page 4: ATTACHMENT A DEMONSTRATION CONFORMANCE

REFERENCES

1. Bordelon, F. M. et. al., "SATAN-VI Program: Comprehensive Space-Time Dependent Analysis of Loss-of-Coolant," WCAP-8302 (Proprietary) and WCAP-8306 (NonProprietary), 1974.

2. Bordelon, F. M. et. al., "LOCTA-IV Program: Loss-of-Coolant Transient Analysis," WCAP-8301 (Proprietary) and WCAP-8305 (Non-Proprietary), 1974.

3. Kelly, R. D. et. al., "Calculational Model for Core Reflooding After a Loss-ofCoolant Accident (WREFLOOD code)," WCAP-8170 (Proprietary) and WCAP-8171 (Non-Proprietary), 1974.

4. Bordelon, F. M. and Murphy, E. T., "Containment Pressure Analysis Code (COCO)," WCAP-8327, (Proprietary) and WCAP-8326 (Non-Proprietary), 1974.

5. Young, M. Y. et. al., "BART-Al: A Computer Code for the Best Estimate Analysis of Reflood Transients," WCAP-9561-P-A (Proprietary) and WCAP-9695-A (NonProprietary), January 1980.

6. Thomas, C. 0., (NRC) "Acceptance for Referencing of Licensing Topical Report WCAP-10484(P)/10485(NP), 'Spacer Grid Heat Transfer Effects During Reflood,"' Letter to E. P. Rahe (Westinghouse), June 21, 1984.

7. Special Report NS-NRC-85-3025(NP), "BART-WREFLOOD Input Revision."

8. Bordelon, F. M., Massie, H. W. and Zordan, T. A., "Westinghouse ECCS Evaluation Model-Summary," WCAP-8339, 1974.

9. Rahe, E. P., "Westinghouse ECCS Evaluation Model, 1981 Version," WCAP-9220-P-A (Proprietary), and WCAP-9221-P-A (Non-Proprietary), Revision 1, 1981.

10. Bordelon, F. M. et al., "Westinghouse ECCS Evaluation Model-Supplementary Information," WCAP-8471, (Proprietary) and WCAP-8472 (Non-Proprietary), 1975.

11. Salvatori, R., "Westinghouse ECCS-Plant Sensitivity Studies," WCAP-8340, (Proprietary) and WCAP-856, (Non-Proprietary), 1974.

12. Butarbaugh, T. L., Julian, H. V., and Tome, A. E., "Westinghouse ECCS-Three Loop Plant (17 x 17) Sensitivity Studies," WCAP-8572-P, (Proprietary), and WCAP-8573-NP (Non-Proprietary), 1975.

13. "Westinghouse ECCS-Evaluation Model Sensitivity Studies," WCAP-8341 (Proprietary) and WCAP-8342 (Non-Proprietary), 1974.

(3015BAT/ccc)

Page 5: ATTACHMENT A DEMONSTRATION CONFORMANCE

TABLE I

COMPARISON OF DESIGN PARAMETERS FOR H. B. ROBINSON UNIT 2 AND TURKEY POINT UNIT 3

H. B. ROBINSON TURKEY POINT PARAMETER UNIT 2 UNIT 3

Core Power (MWth) 2300 2200

Fuel Type Exxon 15 x 15 W 15 x 15 OFA

Barrel Baffle Design Downf low Downf low

Upper Head Temperature Thot Thot

Upper Support Plate Design Flat Flat

Lower Support Plate Design Flat Flat

Steam Generator Type Model 44F Model 44F

Pressurizer Volume (ft 3 ) 1300 1300

Reactor Coolant Pump Model 93 Model 93 6000 hp 6000 hp

Accumulator Total Volume (ft 3 ) 1200 1200

Accumulator Gas Pressure, psia 615 615

Thermal Design Flow (GPM) 88,600* 89,500

* At 5% Steam Generator Tube Plugging Level

(3015BAT/ccc)

Page 6: ATTACHMENT A DEMONSTRATION CONFORMANCE

TABLE 2

LOCA-ECCS ANALYSIS RESULTS

Calculation Basis

License Core Power, MWt 2300

Power Used for Analysis, MWt* 2346

Peak Linear Power for Analysis, kw/ft* 14.20

Total Peaking Factor, F QT 2.32

Enthalpy Rise, Nuclear, FT 1.65 A

Steam Generator Tube Plugging (%) 5.00

Analysis Results Cn = 0.4 DECLG

Peak Clad Temperature (PCT), oF 2199

Peak Clad Temperature Reached, (sec) 108.

Peak Clad Temperature Location, ft. 6.0

Local Zr/H 2 0 Reactor (max.), % 7.09

Local Zr/H 2 0 Location, ft. from Bottom 6.25

Total H2 Generation, % of Total Zr Reacted < 0.3

Hot Rod Burst Time, sec. 41.40

Hot Rod Burst Location, ft. 6.25

* Including 1.02 Factor for Power Uncertainties

(3015BAT/ccc)

Page 7: ATTACHMENT A DEMONSTRATION CONFORMANCE

TABLE 3

LOCA/ECCS TIME SEQUENCE OF EVENTS CD = 0.4 DECLG BREAK

Event Time (sec)

Start 0.0

Safety Injection Signal 0.9

Accumulator Injection 15.1

End-of-Bypass 31.31

Safety Pump Injection 25.9

Bottom-of-Core Recovery 50.11

Accumulators Empty 56.73

Peak Clad Temperature Reached 108.

(3015BAT/ccc)

Page 8: ATTACHMENT A DEMONSTRATION CONFORMANCE

CPL EXXON FUEL FDH=1.65,FQ=2.32,

LOCTA WITH BART UPDATES--ENC FUEL

QUALITY OF FLUID BURST, 6.25 FT( ) PEAK, 6.00 FT(-)

16 0 U

e

L

0

0102

JI]ME (5EC) 11/01/85

Figure 1. FLUID QUALITY - DECLG (C D 0.4)

Page 9: ATTACHMENT A DEMONSTRATION CONFORMANCE

CPL EXXON FUEL FDH=1.65,FQ=2.32,

LOCTA WITH BART UPDATES--ENC FUEL

MASS VELOCITY BURST, 6.25 FT( ) PEAK, 6.00 FT(*)

40 j -20___

4)

L) 60

-100 W il m

eeo o02 105 TIME (SEC)

11/01/85

Figure 2. MASS VELOCITY - DECLG (CD 0.4)

Page 10: ATTACHMENT A DEMONSTRATION CONFORMANCE

CPL EXXON FUEL FDH=1.65.FQ=2.32,

LOCTA WITH BART UPDATES--ENC FUEL

HEAT TRANS.COEFF ICIENT BURST, 6.25 FT( )PEAK, 6.00 FT(*)

Li

L.

(1)

Li

11/01/85

Figure 3. HEAT TRANSFER COEFFICIENT -DECLG (C0D 0.4)

Page 11: ATTACHMENT A DEMONSTRATION CONFORMANCE

CPL EXXON FUEL BART EVALUATION ,CD= 0.4

5 PER CENT SGTP FDH = 1.65 FQT 2.32

PRESSURE CORE BOTTOM ( ) TOP , (")

2sOe

CIC

a2000 -- - _ __ _

1500

0 2 5 5 7 5 10 12 5 15 17 5 20 22 5 25 27 5 50 52 5 TIME (SEC)

1 / 6 8

Figure 4. CORE PRESSURE DECLG (C D 0.4)

Page 12: ATTACHMENT A DEMONSTRATION CONFORMANCE

CPL EXXON FUEL BART EVALUATION ,CD= 0.4

5 PER CENT SGTP FDH 1.65 FQT 2.32

BREAK FLOW

6000E*5

5000E 6

_3

2000E -c

Li

S 0-E *5

0 2 5 5 7 5 10 12 5 15 7 5 20 22 5 25 27 5 50 52 5 TIME (SEC) 10/26/85

Figure 5. BREAK FLOW RATE - DECLG (CD = 0.4)

Page 13: ATTACHMENT A DEMONSTRATION CONFORMANCE

CPL EXXON FUEL BART EVALUATION ,CD= 0.4

5 PER CENT SGTP FDH 1.65 FQT 2.32

CORE PR.DROP

a 60

-90 0 2 5 5 7 5 10 12 5 li 17 5 20 22 5 25 27 5 50 52 5

0T2I1 S E) 710/26/85

Figure 6. CORE PRESSURE DROP - DECLG (CD = 0.4)

Page 14: ATTACHMENT A DEMONSTRATION CONFORMANCE

CPL EXXON FUEL FDH=1.65,FQ=2.32,

LOCTA WITH BART UPDATES--ENC FUEL

CLAD AVG.TEMP.HOT ROD BURST, 6.25 FT( )PEAK, 6.00 FT(*)

C-, 0

0

050

00

CD

-j

0 20 40 60 90 1 00 120 140 160 ISO 200 220 TIME (SECI 1/ /8

Figure 7. PEAK CLAD TEMPERATURE -DECLG (C0D 0.4)

Page 15: ATTACHMENT A DEMONSTRATION CONFORMANCE

CPL EXXON FUEL FDH=1.65,FQ=2.32,

LOCTA WITH BART UPDATES--ENG FUEL

FLUID TEMPERATURE BURST, 6.25 FT( )PEAK, 6.00 FT(*)

Z:. 1750___ __ _ __ _ _ _ _

Li

Li C

Li

Sooa- _

25

S20 20__ 40__ 60_ _010 12_4_10 _0 0 2

TIME (SECI 1018

Figure 8. FLUID TEMPERATURE -DECLG (C D =0.4)

Page 16: ATTACHMENT A DEMONSTRATION CONFORMANCE

CPL EXXON FUEL BART EVALUATION ,CD= 0.4

5 PER CENT SGTP FOH = 1.65 FQT 2.32

Z-FLOWRATE CORE BOTTOM ( ) TOP (*)

9000

U

-6000 '

-4000

Li

-6000

-j

-2000 ____ __ __

-4000 - -_____

-6000 -__

-9000 0 0 2 5 5 7 5 10 12 5 IS 17 5 20 22 5 2S 27 5 50 52 5 TIME (SEC)

10/26/85

Figure 9. CORE FLOW - TOP AND BOTTOM - DECLG (C = 0.4)

Page 17: ATTACHMENT A DEMONSTRATION CONFORMANCE

CPL 15X15 EXXON FUEL 2.32 FQT F-DELTA-H=1.65

EVALUATION BASED ON FPL BART DECKS CD=0.4

WATER LEVEL(FT)

20 ----

17 5

.D JNC(MER . . . . . .

Li

Li -J

TIME (SEC) -10/28/85

Figure 10. REFLOOD TRANSIENT -DECLG (c= 0.4) DOWNCOMER AND CORE WATER LEVPLS

Page 18: ATTACHMENT A DEMONSTRATION CONFORMANCE

CPL 15X15 EXXON FUEL 2.32 FQT F-DELTA-H=1.65

EVALUATION BASED ON FPL BART DECKS CD=0.4

FLOOD RATE(IN/SEC)

Fiur 1. ELOD- RASIN - DEL (C=.4

LCT

0 0

40 60 60 100 120 140 160 180 200 220 240 260 260 500 520 TIMlE I5(C) 10/28/85

Figure 11. REFLOOD TRANSIENT - DECLG (CD= 0.4) CORE INLET VELOCITY

Page 19: ATTACHMENT A DEMONSTRATION CONFORMANCE

CPL EXXON FUEL BART EVALUATION ,CD= 0.4

5 PER CENT SGTP FDH 1.65 FQT 2.32

2000 .

5000

2500

0 2 5 7 5 l0 12 5 is 17 5 20 22 5 25- 27 50 52 S TIME - -- _10/26/85

Figure 12. ACCUMULATOR FLOW (BLOWDOWN) - DECLG (CD = 0.4)

Page 20: ATTACHMENT A DEMONSTRATION CONFORMANCE

PUMPED ECCS FLOW REFLOOD

DECLG (CD=0.4) 5.0

LEGEND 4.5 -

TIME (SEC) 4.0-

S 3.5

LU1 V

I Lai 2.5

Li~~~..1.5

Cc-)

1.0

0 25 50 75 100 125 150 175 200 225 250 275 300

TIME (SEC)

FIGURE 1 3 PUMPED ECCS FLOW (REFLOOD) DECLG (CD=0.4)

Page 21: ATTACHMENT A DEMONSTRATION CONFORMANCE

CPL ECCS COCO INPUT DECK BASED ON FPL

CALC. NOTE SEC-RSA-1371-CO

50. 27.5 - ---- -- - ---- - -- - -

27.5 --- -----

222.5 -U)

20. Li - 17,.5 - ---- - ---- -

U)

12.5.-----z r 10. - --- - - -

z

0.

I

0.

too too 102 5

TIME (SECONDS) 10/28/85

Figure 14. CONTAINMENT PRESSURE - DECLG (C D =0.4)

Page 22: ATTACHMENT A DEMONSTRATION CONFORMANCE

CPL EXXON FUEL BART EVALUATION ,CD= 0.4

5 PER CENT SGTP FDH = 1.65 FQT 2.32

POWER

1 2

0

M

0

0 2 5 5 7 5 10 12 6 15 17 5 20 22 5 26 27 6 50 52 5 TIME (SEC) .10/26/85

Figure 15. CORE POWER TRANSIENT - DECLG (CD = 0.4)

Page 23: ATTACHMENT A DEMONSTRATION CONFORMANCE

CPL EXXON FUEL BART EVALUATION ,CD= 0.4

5 PER CENT SGTP FDH 1.65 FQT 2.32

BREAK ENERGY

5000E* -9

250E* -9

z w~ - - - - --

a

mo 1500E.0

1000E8-9 -- ____

5000E7

0 2 5 5 7 6 10 12 5 I- 17 6 20 22 5 26 27 5 50 52 6 TIME (SEC) 10/26/85

Figure 16. BREAK ENERGY RELEASED TO CONTAINMENT - DECLG (CD = 0.4)