AS100 Installation Air Tight Solutions The only solution AS100 Valve Stem Adapter Small O-ring Large O- ring Standard Brass Valve Stem If you purchased your AS100 * complete it will come assembled as shown If you purchased the AS100 without a valve stem 1. Slide small o-ring down valve stem to bottom of threads 2. Insert the valve stem through the AS100 3. Slide the large o-ring over the end of the AS100 Rim must be clean and free of any type of debris or rust where o-ring seats (wire brushing is recommended) Insuring that the larger o-ring* stays seated in position - slide the assembly through the valve stem hole of the rim Adapter should appear flush with rim surface not caulked *Do not lubricate o-rings in any way – assembly must be installed dry

Upload: prince-wrigley

Post on 14-Dec-2015

219 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: AS100 Installation Air Tight Solutions The only solution AS100 Valve Stem Adapter Small O-ringLarge O-ring Standard Brass Valve Stem If you purchased your

AS100 Installation

Air Tight SolutionsThe only solution

AS100 Valve Stem Adapter

Small O-ringLarge O-ring

Standard Brass Valve Stem

If you purchased your AS100* complete it will come assembled as shown

If you purchased the AS100 without a valve stem1. Slide small o-ring down valve stem to bottom of threads2. Insert the valve stem through the AS1003. Slide the large o-ring over the end of the AS100

Rim must be clean and free of any type of debris or rust where o-ring seats (wire brushing is recommended)Insuring that the larger o-ring* stays seated in position - slide the assembly through the valve stem hole of the rim Adapter should appear flush with rim surface not caulked*Do not lubricate o-rings in any way – assembly must be installed dry

Page 2: AS100 Installation Air Tight Solutions The only solution AS100 Valve Stem Adapter Small O-ringLarge O-ring Standard Brass Valve Stem If you purchased your

AS100 Installation

Air Tight SolutionsThe only solution

Hold the valve stem squarely in the rim with constant hand pressure at the bottom of the valve stem

Slide valve stem washer* and nut down the valve stem

Tighten valve stem nut hand tight to hold valve stem assembly into place

*Dome side of washer must be facing nut

Page 3: AS100 Installation Air Tight Solutions The only solution AS100 Valve Stem Adapter Small O-ringLarge O-ring Standard Brass Valve Stem If you purchased your

AS100 Installation

Air Tight SolutionsThe only solution

*Do not clamp above this point or valve stem may be damaged Tighten valve stem nut as shown holding the valve stem from

turning with a pair of locking pliers – washer must collapse completely and appear to incase the nutDo not allow valve stem to turn during assembly or o-ring damage may occurFinal valve stem recommended nut torque is 20ft. Lbs.**Do not lubricate threads this is a dry torqueThis step must be repeated between tire changes – the AS100 does not need replaced each tire change

125 Judith Dr.Venetia, Pa 15367

Phone (724) [email protected]

Air Tight Solutions is not responsible for any misapplications or improper assembly and installation of the AS100