  • CES Confidential and Proprietary Page 1 of 31

    Application Standard

    Subject This document is for the following applications:

    2013 US EPA Aftertreatment Controls Application Standard

    Automotive Industrial Marine G-Drive Genset Filtration Emissions Solution

    Date: November 10th, 2015 Document Number AS351.01

    Engine Models included: 2013 EPA Heavy Duty & Medium Duty Automotive

    Author: Ragibul Huq(ML305) Page 1 of 31

    This Application Standard outlines the main Aftertreatment System components and the known Cummins Emission Solutions requirements for application in on-highway truck and bus. This document contains information that Cummins Emission Solutions has learned during development to date. Revisions to this document are anticipated as experience is gained. This document should be used by the OEM to assist in vehicle design but is not a substitute for validation of individual vehicle applications of the Aftertreatment System.

    On Board Diagnostics (OBD) Requirements HD OBD The following components are HD OBD regulated. The OEM supplied OBD components are the responsibility of the OEM to implement and install according to the HD OBD Requirements specified in this document.

    HD OBD Components

    Dosing Module (DM) Supply Module (SM) DEF tank temperature sensor DEF tank level sensor DEF quality sensor (optional) DEF line heater and relay DEF tank coolant flow valve DEF Suction, Pressure and Throttle lines Dosing system wiring harness NOx sensors (Engine Out and SCR Out) Wiring from SCR outlet NOx sensor to ACM

    Ammonia (NH3) sensor Exhaust Gas Temperature Sensors (EGTS) Diesel Particulate Filter (DPF) HC Doser DPF Delta Pressure sensor DPF Output Pressure sensor

    This document supersedes the Application Standard dated September 15, 2014

  • CES Confidential and Proprietary Page 2 of 31

    Table of Contents

    1. General Information ................................................................................. 4

    1.1 Purpose ........................................................................................................ 4

    1.2 Reference Documents .................................................................................. 4

    1.4 CES Acronyms ............................................................................................. 5

    2. Installation Requirements ......................................................................... 6

    3. Aftertreatment System ........................................................................... 10

    4. Dosing System (SCR) ............................................................................ 11

    4.1 Dosing System Purging Cycle ................................................................. 11

    4.2 DEF Line Heater Relay ............................................................................... 12

    4.3 DEF Supply Module Heater Relay ............................................................. 12

    4.4 DEF Coolant Flow Valve ............................................................................ 12

    4.5 DEF Tank and Line Heating ....................................................................... 13

    4.6 DEF Tank Temperature Sensing ............................................................. 13

    4.7 DEF Tank Level Sensing Overview ......................................................... 14

    4.7.1 DEF Level Sensor Interface Specifications .................................................... 15

    4.7.2 DEF Level Sensing Warning and Inducement Levels ................................. 15

    4.7.3 Resolution and Accuracy ................................................................................ 15

    4.7.4 Special Considerations for Discrete Step (Float) Level Sensors .................... 16

    4.7.5 Special Considerations for Powered Sensors ................................................ 16

    4.7.6 Special Requirements for Active Sensors ...................................................... 16

    4.7.7 Other Considerations ..................................................................................... 16

    4.8 DEF Level Gauge ....................................................................................... 17

    4.9 DEF Dosing System Harness Connectors ................................................. 17

    5. Aftertreatment Sensors .......................................................................... 18

    5.1 In-Tank DEF Quality Sensor ....................................................................... 18

    5.2 NOx Sensors .............................................................................................. 18

    5.3 Exhaust Gas Temperature Sensors (EGTS) .............................................. 18

    5.4 Ammonia (NH3) Sensor (When applicable) ................................................ 18

    5.5 DPF Dual Delta Pressure and Gage Sensor .............................................. 19

  • CES Confidential and Proprietary Page 3 of 31

    5.6 OEM Ambient Air Temperature Sensor ...................................................... 19

    5.7 Particulate Matter (PM) Sensor .................................................................. 20

    6. SCR End-of-Line (EOL) Test ................................................................. 21

    6.1 Pre EOL Test Conditions ............................................................................ 21

    6.2 EOL Test Procedure ................................................................................... 21

    6.3 EOL Pass Criteria ....................................................................................... 21

    7. DPF End-of-Line (EOL) Test Procedure ................................................ 22

    Appendix A: Electrical Schematic of CM2220-F / CM2220-H Aftertreatment System ....................................................................................................... 23

    Appendix B: Electrical Schematic for Sensors with Delegated Assembly . 24

    Appendix C: Aftertreatment System OEM Connectors .............................. 25

    Appendix D: OEM Connectors Supplier Contact ....................................... 26

    Reference Tables ....................................................................................... 27

    Revision History ......................................................................................... 30

  • CES Confidential and Proprietary Page 4 of 31

    1. General Information

    1.1 Purpose

    The purpose of this document is to provide application guidelines for integrating the Aftertreatment systems including Diesel Particulate Filter (DPF), Selective Catalytic Reduction (SCR) and sensors with the CES, Aftertreatment Control Module (ACM). These guidelines focus on SCR control system requirements for proper system operation, engine diagnostic operation, and compliance with 2013 EPA regulations specific to Engine type. Additional information related to the mechanical installation of the SCR aftertreatment system may be found in 2013 US EPA Aftertreatment Mechanical Installation Requirements.

    1.2 Reference Documents

    AS311.01 2013 US EPA Aftertreatment Mechanical Installation Requirements AS351.03 Remote Mount ACM Application Standard CM2220-F ISO 20653 Road vehicles - Degrees of protection (IP-Code) Protection of electrical equipment against foreign objects, water and access

  • CES Confidential and Proprietary Page 5 of 31

    1.4 CES Acronyms

    ACM Aftertreatment Control Module

    DEF Diesel Exhaust Fluid

    DM Dosing Module

    DM1 Diagnostic Message 1 - Active Diagnostics Trouble Codes

    DPF Diesel Particulate Filter

    DRT Decomposition Reactor Tube

    ECU Electronic Control Unit

    EGTS Exhaust Gas Temperature Sensor

    EOL End-of-Line

    FMI Failure Mode Identifier

    MIL Malfunction Indicator Lamp

    NH3 Ammonia

    OBD On Board Diagnostics

    PM Particulate Matter

    SCR Selective Catalytic Reduction

    SM Supply Module

    SPN Suspect Parameter Number

    VEPS Vehicle Electronic Program Station

  • CES Confidential and Proprietary Page 6 of 31

    2. Installation Requirements

    Because of the complex nature of this installation guideline, the installation requirements will be singled out using bold text MUST for clarity throughout the document. In other words, the use of the term MUST denotes a requirement that must be followed for obtaining CES concurrence for an approved installation of the Aftertreatment system. Aftertreatment Control Module (ACM)

    1. The ACM MUST NOT be exposed to temperatures outside the operating range -40 C and +105 C.

    2. The ACM MUST be mounted in where it meets IP6K9K requirement according to ISO 20653 standard.

    3. The ACM case MUST NOT be in contact with the vehicle chassis ground such that a differential voltage of more than 0.5 volts exists between case and Vbatt (-).

    4. The OEM harness MUST be secured to a point at the same vibration level as the connection between the two in order to reduce relative motion between the mating connectors and reduce fretting corrosion.

    5. The OEM harness MUST be properly supported so that it does not induce excessive tension on the extension connector or the ACM con

Recommended

View more >