application manual for nema motors - · pdf filesiemens energy & automation, inc. hp 1...
TRANSCRIPT
Section 5
Electrical Information Page
Part 1 Frame Assignment
Part 2 Speed Torque Curves GP10 1
GP10A 32
GP100 63
GP100A 88
RGZEESD 113
RGZEESDX 178
RGZESD 241
RGZP (SD) 329
RGZZESD 385
SD10 465
SD100 IEEE-841 496
SD100 521
Part 3 Insulation System
Part 4 External Load WK2 Capabilities
Part 5 Connection Diagrams Single Speed
Two Speed
Part 6 Temperature Rise
Part 7 Reduction Factors
Application Manual for NEMA Motors
SIEMENS ENERGY & AUTOMATION, INC.
HP 1 VOLTS 460 RPM 3600 TYPE GP10
HZ 60 PHASE 3 FRAME 143T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
350%
400%
450%
500%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
800%
900%
1000%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 1 VOLTS 460 RPM 1800 TYPE GP10
HZ 60 PHASE 3 FRAME 143T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
350%
400%
450%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
800%
900%
1000%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 1 VOLTS 460 RPM 1200 TYPE GP10
HZ 60 PHASE 3 FRAME 145T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
350%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 1 VOLTS 460 RPM 900 TYPE GP10
HZ 60 PHASE 3 FRAME 182T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
50%
100%
150%
200%
250%
300%
350%
400%
450%
500%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 1.5 VOLTS 460 RPM 3600 TYPE GP10
HZ 60 PHASE 3 FRAME 182T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
350%
400%
450%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
800%
900%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 1.5 VOLTS 460 RPM 1800 TYPE GP10
HZ 60 PHASE 3 FRAME 145T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
350%
400%
450%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
800%
900%
1000%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 1.5 VOLTS 460 RPM 1200 TYPE GP10
HZ 60 PHASE 3 FRAME 182T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
350%
400%
450%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 1.5 VOLTS 460 RPM 900 TYPE GP10
HZ 60 PHASE 3 FRAME 184T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
350%
400%
450%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 2 VOLTS 460 RPM 3600 TYPE GP10
HZ 60 PHASE 3 FRAME 145T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
350%
400%
450%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
800%
900%
1000%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 2 VOLTS 460 RPM 1800 TYPE GP10
HZ 60 PHASE 3 FRAME 145T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
350%
400%
450%
500%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
800%
900%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 2 VOLTS 460 RPM 1200 TYPE GP10
HZ 60 PHASE 3 FRAME 184T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURVE VS. SPEED
0%
50%
100%
150%
200%
250%
300%
350%
400%
450%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
800%
900%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 2 VOLTS 460 RPM 900 TYPE GP10
HZ 60 PHASE 3 FRAME 213T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
350%
400%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 3 VOLTS 460 RPM 3600 TYPE GP10
HZ 60 PHASE 3 FRAME 182T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
350%
400%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
800%
900%
1000%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 3 VOLTS 460 RPM 1800 TYPE GP10
HZ 60 PHASE 3 FRAME 182T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
350%
400%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
800%
900%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 3 VOLTS 460 RPM 1200 TYPE GP10
HZ 60 PHASE 3 FRAME 213T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
350%
400%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
800%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 3 VOLTS 460 RPM 900 TYPE GP10
HZ 60 PHASE 3 FRAME 215T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
350%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 5 VOLTS 460 RPM 3600 TYPE GP10
HZ 60 PHASE 3 FRAME 184T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
350%
400%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
800%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 5 VOLTS 460 RPM 1800 TYPE GP10
HZ 60 PHASE 3 FRAME 184T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
350%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
800%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 5 VOLTS 460 RPM 1200 TYPE GP10
HZ 60 PHASE 3 FRAME 215T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
350%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
800%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 5 VOLTS 460 RPM 900 TYPE GP10
HZ 60 PHASE 3 FRAME 254T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 7.5 VOLTS 460 RPM 3600 TYPE GP10
HZ 60 PHASE 3 FRAME 213T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
350%
400%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
800%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 7.5 VOLTS 460 RPM 1800 TYPE GP10
HZ 60 PHASE 3 FRAME 213T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
350%
400%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 7.5 VOLTS 460 RPM 1200 TYPE GP10
HZ 60 PHASE 3 FRAME 254T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 7.5 VOLTS 460 RPM 900 TYPE GP10
HZ 60 PHASE 3 FRAME 256T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 10 VOLTS 460 RPM 3600 TYPE GP10
HZ 60 PHASE 3 FRAME 215T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
350%
400%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
800%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 10 VOLTS 460 RPM 1800 TYPE GP10
HZ 60 PHASE 3 FRAME 215T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
350%
400%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 10 VOLTS 460 RPM 1200 TYPE GP10
HZ 60 PHASE 3 FRAME 256T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 15 VOLTS 460 RPM 3600 TYPE GP10
HZ 60 PHASE 3 FRAME 254T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
350%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 15 VOLTS 460 RPM 1800 TYPE GP10
HZ 60 PHASE 3 FRAME 254T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 20 VOLTS 460 RPM 3600 TYPE GP10
HZ 60 PHASE 3 FRAME 256T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 20 VOLTS 460 RPM 1800 TYPE GP10
HZ 60 PHASE 3 FRAME 256T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 1 VOLTS 460 RPM 3600 TYPE GP10A
HZ 60 PHASE 3 FRAME 143T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
350%
400%
450%
500%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
800%
900%
1000%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 1 VOLTS 460 RPM 1800 TYPE GP10A
HZ 60 PHASE 3 FRAME 143T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
350%
400%
450%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
800%
900%
1000%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 1 VOLTS 460 RPM 1200 TYPE GP10A
HZ 60 PHASE 3 FRAME 145T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
350%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 1 VOLTS 460 RPM 900 TYPE GP10A
HZ 60 PHASE 3 FRAME 182T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
50%
100%
150%
200%
250%
300%
350%
400%
450%
500%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 1.5 VOLTS 460 RPM 3600 TYPE GP10A
HZ 60 PHASE 3 FRAME 182T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
350%
400%
450%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
800%
900%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 1.5 VOLTS 460 RPM 1800 TYPE GP10A
HZ 60 PHASE 3 FRAME 145T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
350%
400%
450%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
800%
900%
1000%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 1.5 VOLTS 460 RPM 1200 TYPE GP10A
HZ 60 PHASE 3 FRAME 182T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
350%
400%
450%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 1.5 VOLTS 460 RPM 900 TYPE GP10A
HZ 60 PHASE 3 FRAME 184T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
350%
400%
450%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 2 VOLTS 460 RPM 3600 TYPE GP10A
HZ 60 PHASE 3 FRAME 145T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
350%
400%
450%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
800%
900%
1000%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 2 VOLTS 460 RPM 1800 TYPE GP10A
HZ 60 PHASE 3 FRAME 145T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
350%
400%
450%
500%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
800%
900%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 2 VOLTS 460 RPM 1200 TYPE GP10A
HZ 60 PHASE 3 FRAME 184T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURVE VS. SPEED
0%
50%
100%
150%
200%
250%
300%
350%
400%
450%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
800%
900%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 2 VOLTS 460 RPM 900 TYPE GP10A
HZ 60 PHASE 3 FRAME 213T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
350%
400%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 3 VOLTS 460 RPM 3600 TYPE GP10A
HZ 60 PHASE 3 FRAME 182T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
350%
400%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
800%
900%
1000%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 3 VOLTS 460 RPM 1800 TYPE GP10A
HZ 60 PHASE 3 FRAME 182T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
350%
400%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
800%
900%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 3 VOLTS 460 RPM 1200 TYPE GP10A
HZ 60 PHASE 3 FRAME 213T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
350%
400%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
800%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 3 VOLTS 460 RPM 900 TYPE GP10A
HZ 60 PHASE 3 FRAME 215T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
350%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 5 VOLTS 460 RPM 3600 TYPE GP10A
HZ 60 PHASE 3 FRAME 184T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
350%
400%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
800%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 5 VOLTS 460 RPM 1800 TYPE GP10A
HZ 60 PHASE 3 FRAME 184T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
350%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
800%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 5 VOLTS 460 RPM 1200 TYPE GP10A
HZ 60 PHASE 3 FRAME 215T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
350%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
800%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 5 VOLTS 460 RPM 900 TYPE GP10A
HZ 60 PHASE 3 FRAME 254T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 7.5 VOLTS 460 RPM 3600 TYPE GP10A
HZ 60 PHASE 3 FRAME 213T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
350%
400%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
800%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 7.5 VOLTS 460 RPM 1800 TYPE GP10A
HZ 60 PHASE 3 FRAME 213T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
350%
400%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 7.5 VOLTS 460 RPM 1200 TYPE GP10A
HZ 60 PHASE 3 FRAME 254T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 7.5 VOLTS 460 RPM 900 TYPE GP10A
HZ 60 PHASE 3 FRAME 256T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 10 VOLTS 460 RPM 3600 TYPE GP10A
HZ 60 PHASE 3 FRAME 215T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
350%
400%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
800%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 10 VOLTS 460 RPM 1800 TYPE GP10A
HZ 60 PHASE 3 FRAME 215T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
350%
400%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 10 VOLTS 460 RPM 1200 TYPE GP10A
HZ 60 PHASE 3 FRAME 256T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 15 VOLTS 460 RPM 3600 TYPE GP10A
HZ 60 PHASE 3 FRAME 254T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
350%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 15 VOLTS 460 RPM 1800 TYPE GP10A
HZ 60 PHASE 3 FRAME 254T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 20 VOLTS 460 RPM 3600 TYPE GP10A
HZ 60 PHASE 3 FRAME 256T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 20 VOLTS 460 RPM 1800 TYPE GP10A
HZ 60 PHASE 3 FRAME 256T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 1 VOLTS 460 RPM 3600 TYPE GP100
HZ 60 PHASE 3 FRAME 143T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
350%
400%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 1 VOLTS 460 RPM 1800 TYPE GP100
HZ 60 PHASE 3 FRAME 143T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
350%
400%
450%
500%
550%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
200%
400%
600%
800%
1000%
1200%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 1 VOLTS 460 RPM 1200 TYPE GP100
HZ 60 PHASE 3 FRAME 145T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
350%
400%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
800%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 1.5 VOLTS 460 RPM 3600 TYPE GP100
HZ 60 PHASE 3 FRAME 143T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
350%
400%
450%
500%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
200%
400%
600%
800%
1000%
1200%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 1.5 VOLTS 460 RPM 1800 TYPE GP100
HZ 60 PHASE 3 FRAME 145T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
350%
400%
450%
500%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
800%
900%
1000%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 1.5 VOLTS 460 RPM 1200 TYPE GP100
HZ 60 PHASE 3 FRAME 182T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
350%
400%
450%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
800%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 2 VOLTS 460 RPM 3600 TYPE GP100
HZ 60 PHASE 3 FRAME 145T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
350%
400%
450%
500%
550%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
200%
400%
600%
800%
1000%
1200%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 2 VOLTS 460 RPM 1800 TYPE GP100
HZ 60 PHASE 3 FRAME 145T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
350%
400%
450%
500%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
800%
900%
1000%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 2 VOLTS 460 RPM 1200 TYPE GP100
HZ 60 PHASE 3 FRAME 184T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
350%
400%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
800%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 3 VOLTS 460 RPM 3600 TYPE GP100
HZ 60 PHASE 3 FRAME 182T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
350%
400%
450%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
800%
900%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 3 VOLTS 460 RPM 1800 TYPE GP100
HZ 60 PHASE 3 FRAME 182T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
350%
400%
450%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
800%
900%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 3 VOLTS 460 RPM 1200 TYPE GP100
HZ 60 PHASE 3 FRAME 213T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
350%
400%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
800%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 5 VOLTS 460 RPM 3600 TYPE GP100
HZ 60 PHASE 3 FRAME 184T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
350%
400%
450%
500%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
800%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 5 VOLTS 460 RPM 1800 TYPE GP100
HZ 60 PHASE 3 FRAME 184T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
350%
400%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
800%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 5 VOLTS 460 RPM 1200 TYPE GP100
HZ 60 PHASE 3 FRAME 215T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
350%
400%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
800%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 7.5 VOLTS 460 RPM 3600 TYPE GP100
HZ 60 PHASE 3 FRAME 213T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
350%
400%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
800%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 7.5 VOLTS 460 RPM 1800 TYPE GP100
HZ 60 PHASE 3 FRAME 213T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
350%
400%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 7.5 VOLTS 460 RPM 1200 TYPE GP100
HZ 60 PHASE 3 FRAME 254T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 10 VOLTS 460 RPM 3600 TYPE GP100
HZ 60 PHASE 3 FRAME 215T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
350%
400%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
800%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 10 VOLTS 460 RPM 1800 TYPE GP100
HZ 60 PHASE 3 FRAME 215T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 10 VOLTS 460 RPM 1200 TYPE GP100
HZ 60 PHASE 3 FRAME 256T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 15 VOLTS 460 RPM 3600 TYPE GP100
HZ 60 PHASE 3 FRAME 254T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
350%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
800%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 15 VOLTS 460 RPM 1800 TYPE GP100
HZ 60 PHASE 3 FRAME 254T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
% F
ULL
L0A
D C
UR
REN
T
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 20 VOLTS 460 RPM 3600 TYPE GP100
HZ 60 PHASE 3 FRAME 256T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 20 VOLTS 460 RPM 1800 TYPE GP100
HZ 60 PHASE 3 FRAME 256T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 1 VOLTS 460 RPM 3600 TYPE GP100A
HZ 60 PHASE 3 FRAME 143T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
350%
400%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 1 VOLTS 460 RPM 1800 TYPE GP100A
HZ 60 PHASE 3 FRAME 143T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
350%
400%
450%
500%
550%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
200%
400%
600%
800%
1000%
1200%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 1 VOLTS 460 RPM 1200 TYPE GP100A
HZ 60 PHASE 3 FRAME 145T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
350%
400%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
800%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 1.5 VOLTS 460 RPM 3600 TYPE GP100A
HZ 60 PHASE 3 FRAME 143T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
350%
400%
450%
500%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
200%
400%
600%
800%
1000%
1200%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 1.5 VOLTS 460 RPM 1800 TYPE GP100A
HZ 60 PHASE 3 FRAME 145T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
350%
400%
450%
500%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
800%
900%
1000%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 1.5 VOLTS 460 RPM 1200 TYPE GP100A
HZ 60 PHASE 3 FRAME 182T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
350%
400%
450%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
800%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 2 VOLTS 460 RPM 3600 TYPE GP100A
HZ 60 PHASE 3 FRAME 145T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
350%
400%
450%
500%
550%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
200%
400%
600%
800%
1000%
1200%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 2 VOLTS 460 RPM 1800 TYPE GP100A
HZ 60 PHASE 3 FRAME 145T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
350%
400%
450%
500%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
800%
900%
1000%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 2 VOLTS 460 RPM 1200 TYPE GP100A
HZ 60 PHASE 3 FRAME 184T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
350%
400%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
800%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 3 VOLTS 460 RPM 3600 TYPE GP100A
HZ 60 PHASE 3 FRAME 182T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
350%
400%
450%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
800%
900%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 3 VOLTS 460 RPM 1800 TYPE GP100A
HZ 60 PHASE 3 FRAME 182T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
350%
400%
450%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
800%
900%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 3 VOLTS 460 RPM 1200 TYPE GP100A
HZ 60 PHASE 3 FRAME 213T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
350%
400%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
800%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 5 VOLTS 460 RPM 3600 TYPE GP100A
HZ 60 PHASE 3 FRAME 184T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
350%
400%
450%
500%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
800%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 5 VOLTS 460 RPM 1800 TYPE GP100A
HZ 60 PHASE 3 FRAME 184T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
350%
400%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
800%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 5 VOLTS 460 RPM 1200 TYPE GP100A
HZ 60 PHASE 3 FRAME 215T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
350%
400%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
800%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 7.5 VOLTS 460 RPM 3600 TYPE GP100A
HZ 60 PHASE 3 FRAME 213T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
350%
400%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
800%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 7.5 VOLTS 460 RPM 1800 TYPE GP100A
HZ 60 PHASE 3 FRAME 213T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
350%
400%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 7.5 VOLTS 460 RPM 1200 TYPE GP100A
HZ 60 PHASE 3 FRAME 254T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 10 VOLTS 460 RPM 3600 TYPE GP100A
HZ 60 PHASE 3 FRAME 215T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
350%
400%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
800%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 10 VOLTS 460 RPM 1800 TYPE GP100A
HZ 60 PHASE 3 FRAME 215T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 10 VOLTS 460 RPM 1200 TYPE GP100A
HZ 60 PHASE 3 FRAME 256T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 15 VOLTS 460 RPM 3600 TYPE GP100A
HZ 60 PHASE 3 FRAME 254T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
350%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
800%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 15 VOLTS 460 RPM 1800 TYPE GP100A
HZ 60 PHASE 3 FRAME 254T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
% F
ULL
L0A
D C
UR
REN
T
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 20 VOLTS 460 RPM 3600 TYPE GP100A
HZ 60 PHASE 3 FRAME 256T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 20 VOLTS 460 RPM 1800 TYPE GP100A
HZ 60 PHASE 3 FRAME 256T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 1 VOLTS 230/460 RPM 1800 TYPE RGZEESD
HZ 60 PHASE 3 FRAME 143T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
350%
400%
450%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
800%
% F
ULL
LO
AD
CU
RR
ENTTORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 1 VOLTS 230/460 RPM 1200 TYPE RGZEESD
HZ 60 PHASE 3 FRAME 145T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
350%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
% F
ULL
LO
AD
CU
RR
ENTTORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 1.5 VOLTS 230/460 RPM 3600 TYPE RGZEESD
HZ 60 PHASE 3 FRAME 143T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
350%
400%
450%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
800%
900%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 1.5 VOLTS 230/460 RPM 1800 TYPE RGZEESD
HZ 60 PHASE 3 FRAME 145T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
350%
400%
450%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
800%
900%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 1.5 VOLTS 230/460 RPM 1200 TYPE RGZEESD
HZ 60 PHASE 3 FRAME 182T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
350%
400%
450%
500%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
800%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 2 VOLTS 230/460 RPM 3600 TYPE RGZEESD
HZ 60 PHASE 3 FRAME 145T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
350%
400%
450%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
800%
900%
1000%
% F
ULL
LO
AD
CU
RR
ENTTORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 2 VOLTS 230/460 RPM 1800 TYPE RGZEESD
HZ 60 PHASE 3 FRAME 145T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
350%
400%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
800%
% F
ULL
LO
AD
CU
RR
ENTTORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 2 VOLTS 230/460 RPM 1200 TYPE RGZEESD
HZ 60 PHASE 3 FRAME 184T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
350%
400%
450%
500%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
800%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 3 VOLTS 230/460 RPM 3600 TYPE RGZEESD
HZ 60 PHASE 3 FRAME 182T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
350%
400%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
800%
900%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 3 VOLTS 230/460 RPM 1800 TYPE RGZEESD
HZ 60 PHASE 3 FRAME 182T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
350%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
800%
900%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 3 VOLTS 230/460 RPM 1200 TYPE RGZEESD
HZ 60 PHASE 3 FRAME 213T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
350%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
800%
900%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 5 VOLTS 230/460 RPM 3600 TYPE RGZEESD
HZ 60 PHASE 3 FRAME 184T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
350%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
800%
900%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 5 VOLTS 230/460 RPM 1800 TYPE RGZEESD
HZ 60 PHASE 3 FRAME 184T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
350%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
800%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 5 VOLTS 230/460 RPM 1200 TYPE RGZEESD
HZ 60 PHASE 3 FRAME 215T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
350%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
800%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 7.5 VOLTS 230/460 RPM 3600 TYPE RGZEESD
HZ 60 PHASE 3 FRAME 213T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
350%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
800%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 7.5 VOLTS 230/460 RPM 1800 TYPE RGZEESD
HZ 60 PHASE 3 FRAME 213T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
350%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
800%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 7.5 VOLTS 230/460 RPM 1200 TYPE RGZEESD
HZ 60 PHASE 3 FRAME 254T NEMA B
Customer: PO No.: Order No.:
TORQUE VS. SPEED
0%
50%
100%
150%
200%
250%
300%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
TORQUE
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 10 VOLTS 230/460 RPM 3600 TYPE RGZEESD
HZ 60 PHASE 3 FRAME 215T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
350%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
800%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 10 VOLTS 230/460 RPM 1800 TYPE RGZEESD
HZ 60 PHASE 3 FRAME 215T NEMA B
Customer: PO No.: Order No.:
TORQUE VS. SPEED
0%
50%
100%
150%
200%
250%
300%
350%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
TORQUE
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 10 VOLTS 230/460 RPM 1200 TYPE RGZEESD
HZ 60 PHASE 3 FRAME 256T NEMA B
Customer: PO No.: Order No.:
TORQUE VS. SPEED
0%
50%
100%
150%
200%
250%
300%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
TORQUE
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 15 VOLTS 230/460 RPM 3600 TYPE RGZEESD
HZ 60 PHASE 3 FRAME 254T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
800%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 15 VOLTS 230/460 RPM 1800 TYPE RGZEESD
HZ 60 PHASE 3 FRAME 254T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 15 VOLTS 230/460 RPM 1200 TYPE RGZEESD
HZ 60 PHASE 3 FRAME 284T NEMA B
Customer: PO No.: Order No.:
TORQUE AND CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 20 VOLTS 230/460 RPM 3600 TYPE RGZEESD
HZ 60 PHASE 3 FRAME 256T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 20 VOLTS 230/460 RPM 1800 TYPE RGZEESD
HZ 60 PHASE 3 FRAME 256T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 20 VOLTS 230/460 RPM 1200 TYPE RGZEESD
HZ 60 PHASE 3 FRAME 286T NEMA B
Customer: PO No.: Order No.:
TORQUE AND CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 25 VOLTS 460 RPM 3600 TYPE RGZEESD
HZ 60 PHASE 3 FRAME 284TS NEMA B
Customer: PO No.: Order No.:
TORQUE AND CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 25 VOLTS 460 RPM 1800 TYPE RGZEESD
HZ 60 PHASE 3 FRAME 284T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 25 VOLTS 230/460 RPM 1200 TYPE RGZEESD
HZ 60 PHASE 3 FRAME 324T NEMA B
Customer: PO No.: Order No.:
TORQUE AND CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
% F
ULL
LO
AD
CU
RR
ENTTORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 30 VOLTS 230/460 RPM 3600 TYPE RGZEESD
HZ 60 PHASE 3 FRAME 286TS NEMA B
Customer: PO No.: Order No.:
TORQUE AND CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 30 VOLTS 460 RPM 1800 TYPE RGZEESD
HZ 60 PHASE 3 FRAME 286T NEMA B
Customer: PO No.: Order No.:
TORQUE AND CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
% F
ULL
LO
AD
CU
RR
ENTTORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 30 VOLTS 460 RPM 1200 TYPE RGZEESD
HZ 60 PHASE 3 FRAME 326T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 40 VOLTS 460 RPM 3600 TYPE RGZEESD
HZ 60 PHASE 3 FRAME 324TS NEMA B
Customer: PO No.: Order No.:
TORQUE AND CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 40 VOLTS 460 RPM 1800 TYPE RGZEESD
HZ 60 PHASE 3 FRAME 324T NEMA B
Customer: PO No.: Order No.:
TORQUE AND CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 40 VOLTS 460 RPM 1200 TYPE RGZEESD
HZ 60 PHASE 3 FRAME 364T NEMA B
Customer: PO No.: Order No.:
TORQUE AND CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
1 26 51 76 101
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 50 VOLTS 460 RPM 3600 TYPE RGZEESD
HZ 60 PHASE 3 FRAME 326TS NEMA B
Customer: PO No.: Order No.:
TORQUE AND CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 50 VOLTS 460 RPM 1800 TYPE RGZEESD
HZ 60 PHASE 3 FRAME 326T NEMA B
Customer: PO No.: Order No.:
TORQUE VS. SPEED
0%
50%
100%
150%
200%
250%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
TORQUE
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 60 VOLTS 460 RPM 3600 TYPE RGZEESD
HZ 60 PHASE 3 FRAME 364TS NEMA B
Customer: PO No.: Order No.:
TORQUE AND CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 60 VOLTS 460 RPM 1800 TYPE RGZEESD
HZ 60 PHASE 3 FRAME 364T NEMA B
Customer: PO No.: Order No.:
TORQUE VS. SPEED
0%
50%
100%
150%
200%
250%
300%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
TORQUE
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 50 VOLTS 460 RPM 1200 TYPE RGZEESD
HZ 60 PHASE 3 FRAME 365T NEMA B
Customer: PO No.: Order No.:
TORQUE AND CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
1 26 51 76 101
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 75 VOLTS 460 RPM 3600 TYPE RGZEESD
HZ 60 PHASE 3 FRAME 365TS NEMA B
Customer: PO No.: Order No.:
TORQUE AND CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 75 VOLTS 460 RPM 1800 TYPE RGZEESD
HZ 60 PHASE 3 FRAME 365T NEMA B
Customer: PO No.: Order No.:
TORQUE VS. SPEED
0%
50%
100%
150%
200%
250%
300%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
TORQUE
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 75 VOLTS 460 RPM 1200 TYPE RGZEESD
HZ 60 PHASE 3 FRAME 405T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 100 VOLTS 460 RPM 3600 TYPE RGZEESD
HZ 60 PHASE 3 FRAME 405TS NEMA B
Customer: PO No.: Order No.:
TORQUE AND CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
800%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 100 VOLTS 460 RPM 1800 TYPE RGZEESD
HZ 60 PHASE 3 FRAME 405TS NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 100 VOLTS 460 RPM 1200 TYPE RGZEESD
HZ 60 PHASE 3 FRAME 444T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 125 VOLTS 460 RPM 3600 TYPE RGZEESD
HZ 60 PHASE 3 FRAME 444TS NEMA B
Customer: PO No.: Order No.:
TORQUE AND CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
% F
ULL
LO
AD
CU
RR
ENTTORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 125 VOLTS 460 RPM 1800 TYPE RGZEESD
HZ 60 PHASE 3 FRAME 444TS NEMA B
Customer: PO No.: Order No.:
TORQUE AND CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 125 VOLTS 460 RPM 1200 TYPE RGZEESD
HZ 60 PHASE 3 FRAME 445T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 150 VOLTS 460 RPM 3600 TYPE RGZEESD
HZ 60 PHASE 3 FRAME 445TS NEMA B
Customer: PO No.: Order No.:
TORQUE AND CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 150 VOLTS 460 RPM 1800 TYPE RGZEESD
HZ 60 PHASE 3 FRAME 445T NEMA B
Customer: PO No.: Order No.:
TORQUE VS. SPEED
0%
50%
100%
150%
200%
250%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
TORQUE
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 150 VOLTS 460 RPM 1200 TYPE RGZEESD
HZ 60 PHASE 3 FRAME 447T NEMA B
Customer: PO No.: Order No.:
TORQUE AND CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
% F
ULL
LO
AD
CU
RR
ENTTORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 200 VOLTS 460 RPM 3600 TYPE RGZEESD
HZ 60 PHASE 3 FRAME 447TS NEMA B
Customer: PO No.: Order No.:
TORQUE AND CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
800%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 200 VOLTS 460 RPM 1800 TYPE RGZEESD
HZ 60 PHASE 3 FRAME 447T NEMA B
Customer: PO No.: Order No.:
TORQUE VS. SPEED
0%
50%
100%
150%
200%
250%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
TORQUE
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 200 VOLTS 460 RPM 1200 TYPE RGZEESD
HZ 60 PHASE 3 FRAME 449TS NEMA B
Customer: PO No.: Order No.:
TORQUE AND CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.MOTORS & DRIVES DIVISION
HP 250 VOLTS 460 RPM 3600 TYPE RGZEESD
HZ 60 PHASE 3 FRAME 449TS NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
800%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.MOTORS & DRIVES DIVISION
HP 250 VOLTS 460 RPM 1800 TYPE RGZEESD
HZ 60 PHASE 3 FRAME 449TS NEMA A
Customer: PO No.: Order No.:
TORQUE VS. SPEED
0%
50%
100%
150%
200%
250%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
TORQUE
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.MOTORS & DRIVES DIVISION
HP 250 VOLTS 460 RPM 1200 TYPE RGZEESD
HZ 60 PHASE 3 FRAME 449TS NEMA A
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 300 VOLTS 460 RPM 3600 TYPE RGZEESD
HZ 60 PHASE 3 FRAME 449TS NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
800%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.MOTORS & DRIVES DIVISION
HP 300 VOLTS 460 RPM 1800 TYPE RGZEESD
HZ 60 PHASE 3 FRAME 449TS NEMA A
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.MOTORS & DRIVES DIVISION
HP 300 VOLTS 460 RPM 1200 TYPE RGZEESD
HZ 60 PHASE 3 FRAME S449 NEMA A
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 350 VOLTS 460 RPM 3600 TYPE RGZEESD
HZ 60 PHASE 3 FRAME S449SS NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
800%
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.MOTORS & DRIVES DIVISION
HP 350 VOLTS 460 RPM 1800 TYPE RGZEESD
HZ 60 PHASE 3 FRAME S449 NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.MOTORS & DRIVES DIVISION
HP 400 VOLTS 460 RPM 3600 TYPE RGZEESD
HZ 60 PHASE 3 FRAME S449SS NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
800%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.MOTORS & DRIVES DIVISION
HP 400 VOLTS 460 RPM 1800 TYPE RGZEESD
HZ 60 PHASE 3 FRAME S449 NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 1 VOLTS 460 RPM 1800 TYPE RGZEESDX
HZ 60 PHASE 3 FRAME 143T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
350%
400%
450%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
800%
% F
ULL
LO
AD
CU
RR
ENTTORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 1 VOLTS 460 RPM 1200 TYPE RGZEESDX
HZ 60 PHASE 3 FRAME 145T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
350%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
% F
ULL
LO
AD
CU
RR
ENTTORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 1.5 VOLTS 460 RPM 3600 TYPE RGZEESDX
HZ 60 PHASE 3 FRAME 143T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
350%
400%
450%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
800%
900%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 1.5 VOLTS 460 RPM 1800 TYPE RGZEESDX
HZ 60 PHASE 3 FRAME 145T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
350%
400%
450%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
800%
900%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 1.5 VOLTS 460 RPM 1200 TYPE RGZEESDX
HZ 60 PHASE 3 FRAME 182T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
350%
400%
450%
500%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
800%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 2 VOLTS 460 RPM 3600 TYPE RGZEESDX
HZ 60 PHASE 3 FRAME 145T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
350%
400%
450%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
800%
900%
1000%
% F
ULL
LO
AD
CU
RR
ENTTORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 2 VOLTS 460 RPM 1800 TYPE RGZEESDX
HZ 60 PHASE 3 FRAME 145T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
350%
400%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
800%
% F
ULL
LO
AD
CU
RR
ENTTORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 2 VOLTS 460 RPM 1200 TYPE RGZEESDX
HZ 60 PHASE 3 FRAME 184T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
350%
400%
450%
500%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
800%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 3 VOLTS 460 RPM 3600 TYPE RGZEESDX
HZ 60 PHASE 3 FRAME 182T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
350%
400%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
800%
900%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 3 VOLTS 460 RPM 1800 TYPE RGZEESDX
HZ 60 PHASE 3 FRAME 182T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
350%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
800%
900%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 3 VOLTS 460 RPM 1200 TYPE RGZEESDX
HZ 60 PHASE 3 FRAME 213T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
350%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
800%
900%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 5 VOLTS 460 RPM 3600 TYPE RGZEESDX
HZ 60 PHASE 3 FRAME 184T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
350%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
800%
900%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 5 VOLTS 460 RPM 1800 TYPE RGZEESDX
HZ 60 PHASE 3 FRAME 184T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
350%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
800%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 5 VOLTS 460 RPM 1200 TYPE RGZEESDX
HZ 60 PHASE 3 FRAME 215T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
350%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
800%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 7.5 VOLTS 460 RPM 3600 TYPE RGZEESDX
HZ 60 PHASE 3 FRAME 213T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
350%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
800%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 7.5 VOLTS 460 RPM 1800 TYPE RGZEESDX
HZ 60 PHASE 3 FRAME 213T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
350%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
800%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 7.5 VOLTS 460 RPM 1200 TYPE RGZEESDX
HZ 60 PHASE 3 FRAME 254T NEMA B
Customer: PO No.: Order No.:
TORQUE VS. SPEED
0%
50%
100%
150%
200%
250%
300%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
TORQUE
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 10 VOLTS 460 RPM 3600 TYPE RGZEESDX
HZ 60 PHASE 3 FRAME 215T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
350%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
800%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 10 VOLTS 460 RPM 1800 TYPE RGZEESDX
HZ 60 PHASE 3 FRAME 215T NEMA B
Customer: PO No.: Order No.:
TORQUE VS. SPEED
0%
50%
100%
150%
200%
250%
300%
350%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
TORQUE
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 10 VOLTS 460 RPM 1200 TYPE RGZEESDX
HZ 60 PHASE 3 FRAME 256T NEMA B
Customer: PO No.: Order No.:
TORQUE VS. SPEED
0%
50%
100%
150%
200%
250%
300%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
TORQUE
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 15 VOLTS 460 RPM 3600 TYPE RGZEESDX
HZ 60 PHASE 3 FRAME 254T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
800%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 15 VOLTS 460 RPM 1800 TYPE RGZEESDX
HZ 60 PHASE 3 FRAME 254T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 15 VOLTS 460 RPM 1200 TYPE RGZEESDX
HZ 60 PHASE 3 FRAME 284T NEMA B
Customer: PO No.: Order No.:
TORQUE AND CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 20 VOLTS 460 RPM 3600 TYPE RGZEESDX
HZ 60 PHASE 3 FRAME 256T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 20 VOLTS 460 RPM 1800 TYPE RGZEESDX
HZ 60 PHASE 3 FRAME 256T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 20 VOLTS 460 RPM 1200 TYPE RGZEESDX
HZ 60 PHASE 3 FRAME 286T NEMA B
Customer: PO No.: Order No.:
TORQUE AND CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 25 VOLTS 460 RPM 3600 TYPE RGZEESDX
HZ 60 PHASE 3 FRAME 284TS NEMA B
Customer: PO No.: Order No.:
TORQUE AND CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 25 VOLTS 460 RPM 1800 TYPE RGZEESDX
HZ 60 PHASE 3 FRAME 284T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 25 VOLTS 460 RPM 1200 TYPE RGZEESDX
HZ 60 PHASE 3 FRAME 324T NEMA B
Customer: PO No.: Order No.:
TORQUE AND CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
% F
ULL
LO
AD
CU
RR
ENTTORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 30 VOLTS 460 RPM 3600 TYPE RGZEESDX
HZ 60 PHASE 3 FRAME 286TS NEMA B
Customer: PO No.: Order No.:
TORQUE AND CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 30 VOLTS 460 RPM 1800 TYPE RGZEESDX
HZ 60 PHASE 3 FRAME 286T NEMA B
Customer: PO No.: Order No.:
TORQUE AND CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
% F
ULL
LO
AD
CU
RR
ENTTORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 30 VOLTS 460 RPM 1200 TYPE RGZEESDX
HZ 60 PHASE 3 FRAME 326T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 40 VOLTS 460 RPM 3600 TYPE RGZEESDX
HZ 60 PHASE 3 FRAME 324TS NEMA B
Customer: PO No.: Order No.:
TORQUE AND CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 40 VOLTS 460 RPM 1800 TYPE RGZEESDX
HZ 60 PHASE 3 FRAME 324T NEMA B
Customer: PO No.: Order No.:
TORQUE AND CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 40 VOLTS 460 RPM 1200 TYPE RGZEESDX
HZ 60 PHASE 3 FRAME 364T NEMA B
Customer: PO No.: Order No.:
TORQUE AND CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
1 26 51 76 101
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 50 VOLTS 460 RPM 3600 TYPE RGZEESDX
HZ 60 PHASE 3 FRAME 326TS NEMA B
Customer: PO No.: Order No.:
TORQUE AND CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 50 VOLTS 460 RPM 1800 TYPE RGZEESDX
HZ 60 PHASE 3 FRAME 326T NEMA B
Customer: PO No.: Order No.:
TORQUE VS. SPEED
0%
50%
100%
150%
200%
250%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
TORQUE
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 50 VOLTS 460 RPM 1200 TYPE RGZEESDX
HZ 60 PHASE 3 FRAME 365T NEMA B
Customer: PO No.: Order No.:
TORQUE AND CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
1 26 51 76 101
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 60 VOLTS 460 RPM 3600 TYPE RGZEESDX
HZ 60 PHASE 3 FRAME 364TS NEMA B
Customer: PO No.: Order No.:
TORQUE AND CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 60 VOLTS 460 RPM 1800 TYPE RGZEESDX
HZ 60 PHASE 3 FRAME 364T NEMA B
Customer: PO No.: Order No.:
TORQUE VS. SPEED
0%
50%
100%
150%
200%
250%
300%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
TORQUE
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 75 VOLTS 460 RPM 3600 TYPE RGZEESDX
HZ 60 PHASE 3 FRAME 365TS NEMA B
Customer: PO No.: Order No.:
TORQUE AND CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 75 VOLTS 460 RPM 1800 TYPE RGZEESDX
HZ 60 PHASE 3 FRAME 365T NEMA B
Customer: PO No.: Order No.:
TORQUE VS. SPEED
0%
50%
100%
150%
200%
250%
300%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
TORQUE
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 75 VOLTS 460 RPM 1200 TYPE RGZEESDX
HZ 60 PHASE 3 FRAME 405T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 100 VOLTS 460 RPM 3600 TYPE RGZEESDX
HZ 60 PHASE 3 FRAME 405TS NEMA B
Customer: PO No.: Order No.:
TORQUE AND CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
800%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 100 VOLTS 460 RPM 1800 TYPE RGZEESDX
HZ 60 PHASE 3 FRAME 405TS NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 100 VOLTS 460 RPM 1200 TYPE RGZEESDX
HZ 60 PHASE 3 FRAME 444T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 125 VOLTS 460 RPM 3600 TYPE RGZEESDX
HZ 60 PHASE 3 FRAME 444TS NEMA B
Customer: PO No.: Order No.:
TORQUE AND CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
% F
ULL
LO
AD
CU
RR
ENTTORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 125 VOLTS 460 RPM 1800 TYPE RGZEESDX
HZ 60 PHASE 3 FRAME 444TS NEMA B
Customer: PO No.: Order No.:
TORQUE AND CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 125 VOLTS 460 RPM 1200 TYPE RGZEESDX
HZ 60 PHASE 3 FRAME 445T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 150 VOLTS 460 RPM 3600 TYPE RGZEESDX
HZ 60 PHASE 3 FRAME 445TS NEMA B
Customer: PO No.: Order No.:
TORQUE AND CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 150 VOLTS 460 RPM 1800 TYPE RGZEESDX
HZ 60 PHASE 3 FRAME 445T NEMA B
Customer: PO No.: Order No.:
TORQUE VS. SPEED
0%
50%
100%
150%
200%
250%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
TORQUE
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 150 VOLTS 460 RPM 1200 TYPE RGZEESDX
HZ 60 PHASE 3 FRAME 447T NEMA B
Customer: PO No.: Order No.:
TORQUE AND CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
% F
ULL
LO
AD
CU
RR
ENTTORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 200 VOLTS 460 RPM 3600 TYPE RGZEESDX
HZ 60 PHASE 3 FRAME 447TS NEMA B
Customer: PO No.: Order No.:
TORQUE AND CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
800%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 200 VOLTS 460 RPM 1800 TYPE RGZEESDX
HZ 60 PHASE 3 FRAME 447T NEMA B
Customer: PO No.: Order No.:
TORQUE VS. SPEED
0%
50%
100%
150%
200%
250%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
TORQUE
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 200 VOLTS 460 RPM 1200 TYPE RGZEESDX
HZ 60 PHASE 3 FRAME 449TS NEMA B
Customer: PO No.: Order No.:
TORQUE AND CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.MOTORS & DRIVES DIVISION
HP 250 VOLTS 460 RPM 3600 TYPE RGZEESDX
HZ 60 PHASE 3 FRAME 449TS NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
800%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.MOTORS & DRIVES DIVISION
HP 250 VOLTS 460 RPM 1800 TYPE RGZEESDX
HZ 60 PHASE 3 FRAME 449TS NEMA A
Customer: PO No.: Order No.:
TORQUE VS. SPEED
0%
50%
100%
150%
200%
250%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
TORQUE
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.MOTORS & DRIVES DIVISION
HP 250 VOLTS 460 RPM 1200 TYPE RGZEESDX
HZ 60 PHASE 3 FRAME 449TS NEMA A
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.MOTORS & DRIVES DIVISION
HP 300 VOLTS 460 RPM 1800 TYPE RGZEESDX
HZ 60 PHASE 3 FRAME S449 NEMA A
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.MOTORS & DRIVES DIVISION
HP 300 VOLTS 460 RPM 1200 TYPE RGZEESDX
HZ 60 PHASE 3 FRAME S449 NEMA A
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 350 VOLTS 460 RPM 3600 TYPE RGZEESDX
HZ 60 PHASE 3 FRAME S449SS NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
800%
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.MOTORS & DRIVES DIVISION
HP 350 VOLTS 460 RPM 1800 TYPE RGZEESDX
HZ 60 PHASE 3 FRAME S449 NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.MOTORS & DRIVES DIVISION
HP 400 VOLTS 460 RPM 3600 TYPE RGZEESDX
HZ 60 PHASE 3 FRAME S449SS NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
800%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 1 VOLTS 230/460 RPM 1800 TYPE RGZESD
HZ 60 PHASE 3 FRAME 143T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
350%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
800%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 1 VOLTS 230/460 RPM 1200 TYPE RGZESD
HZ 60 PHASE 3 FRAME 145T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
350%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 1 VOLTS 230/460 RPM 900 TYPE RGZESD
HZ 60 PHASE 3 FRAME 182T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
50%
100%
150%
200%
250%
300%
350%
400%
450%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 1.5 VOLTS 230/460 RPM 3600 TYPE RGZESD
HZ 60 PHASE 3 FRAME 143T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
350%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
800%
900%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 1.5 VOLTS 230/460 RPM 1800 TYPE RGZESD
HZ 60 PHASE 3 FRAME 145T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
350%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
800%
900%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 1.5 VOLTS 230/460 RPM 1200 TYPE RGZESD
HZ 60 PHASE 3 FRAME 182T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
350%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
800%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 1.5 VOLTS 230/460 RPM 900 TYPE RGZESD
HZ 60 PHASE 3 FRAME 184T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 2 VOLTS 230/460 RPM 3600 TYPE RGZESD
HZ 60 PHASE 3 FRAME 145T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
350%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
800%
900%
1000%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 2 VOLTS 230/460 RPM 1800 TYPE RGZESD
HZ 60 PHASE 3 FRAME 145T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
350%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
800%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 2 VOLTS 230/460 RPM 1200 TYPE RGZESD
HZ 60 PHASE 3 FRAME 184T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
350%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
800%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 2 VOLTS 230/460 RPM 900 TYPE RGZESD
HZ 60 PHASE 3 FRAME 213T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
350%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 3 VOLTS 230/460 RPM 3600 TYPE RGZESD
HZ 60 PHASE 3 FRAME 182T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
350%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
800%
900%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 3 VOLTS 230/460 RPM 1800 TYPE RGZESD
HZ 60 PHASE 3 FRAME 182T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
350%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
800%
900%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 3 VOLTS 230/460 RPM 1200 TYPE RGZESD
HZ 60 PHASE 3 FRAME 213T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
350%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
800%
900%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 3 VOLTS 230/460 RPM 900 TYPE RGZESD
HZ 60 PHASE 3 FRAME 215T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 5 VOLTS 230/460 RPM 3600 TYPE RGZESD
HZ 60 PHASE 3 FRAME 184T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
350%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
800%
900%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 5 VOLTS 230/460 RPM 1800 TYPE RGZESD
HZ 60 PHASE 3 FRAME 184T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
350%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
800%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 5 VOLTS 230/460 RPM 1200 TYPE RGZESD
HZ 60 PHASE 3 FRAME 215T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
350%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
800%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 5 VOLTS 230/460 RPM 900 TYPE RGZESD
HZ 60 PHASE 3 FRAME 254T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
% F
ULL
LO
AD
CU
RR
ENTTORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 7.5 VOLTS 230/460 RPM 3600 TYPE RGZESD
HZ 60 PHASE 3 FRAME 213T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
800%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 7.5 VOLTS 230/460 RPM 1800 TYPE RGZESD
HZ 60 PHASE 3 FRAME 213T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
800%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 7.5 VOLTS 230/460 RPM 1200 TYPE RGZESD
HZ 60 PHASE 3 FRAME 254T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 7.5 VOLTS 230/460 RPM 900 TYPE RGZESD
HZ 60 PHASE 3 FRAME 256T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 10 VOLTS 230/460 RPM 3600 TYPE RGZESD
HZ 60 PHASE 3 FRAME 215T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
800%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 10 VOLTS 230/460 RPM 1800 TYPE RGZESD
HZ 60 PHASE 3 FRAME 215T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 10 VOLTS 230/460 RPM 1200 TYPE RGZESD
HZ 60 PHASE 3 FRAME 256T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 10 VOLTS 230/460 RPM 900 TYPE RGZESD
HZ 60 PHASE 3 FRAME 284T NEMA B
Customer: PO No.: Order No.:
TORQUE AND CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
% F
ULL
LO
AD
CU
RR
ENTTORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 15 VOLTS 230/460 RPM 3600 TYPE RGZESD
HZ 60 PHASE 3 FRAME 254T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
800%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 15 VOLTS 230/460 RPM 1800 TYPE RGZESD
HZ 60 PHASE 3 FRAME 254T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 15 VOLTS 230/460 RPM 1200 TYPE RGZESD
HZ 60 PHASE 3 FRAME 284T NEMA B
Customer: PO No.: Order No.:
TORQUE AND CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 15 VOLTS 230/460 RPM 900 TYPE RGZESD
HZ 60 PHASE 3 FRAME 286T NEMA B
Customer: PO No.: Order No.:
TORQUE AND CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
% F
ULL
LO
AD
CU
RR
ENTTORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 20 VOLTS 230/460 RPM 3600 TYPE RGZESD
HZ 60 PHASE 3 FRAME 256T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 20 VOLTS 230/460 RPM 1800 TYPE RGZESD
HZ 60 PHASE 3 FRAME 256T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 20 VOLTS 230/460 RPM 1200 TYPE RGZESD
HZ 60 PHASE 3 FRAME 286T NEMA B
Customer: PO No.: Order No.:
TORQUE AND CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 20 VOLTS 230/460 RPM 900 TYPE RGZESD
HZ 60 PHASE 3 FRAME 324T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
50%
100%
150%
200%
250%
300%
350%
400%
450%
500%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 25 VOLTS 460 RPM 3600 TYPE RGZESD
HZ 60 PHASE 3 FRAME 284TS NEMA B
Customer: PO No.: Order No.:
TORQUE AND CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 25 VOLTS 460 RPM 1800 TYPE RGZESD
HZ 60 PHASE 3 FRAME 284T NEMA B
Customer: PO No.: Order No.:
TORQUE AND CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 25 VOLTS 460 RPM 1200 TYPE RGZESD
HZ 60 PHASE 3 FRAME 324T NEMA B
Customer: PO No.: Order No.:
TORQUE AND CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
% F
ULL
LO
AD
CU
RR
ENTTORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 25 VOLTS 460 RPM 900 TYPE RGZESD
HZ 60 PHASE 3 FRAME 326T NEMA B
Customer: PO No.: Order No.:
TORQUE AND CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
50%
100%
150%
200%
250%
300%
350%
400%
450%
500%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 30 VOLTS 460 RPM 3600 TYPE RGZESD
HZ 60 PHASE 3 FRAME 286TS NEMA B
Customer: PO No.: Order No.:
TORQUE AND CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 30 VOLTS 460 RPM 1800 TYPE RGZESD
HZ 60 PHASE 3 FRAME 286T NEMA B
Customer: PO No.: Order No.:
TORQUE AND CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 30 VOLTS 460 RPM 1200 TYPE RGZESD
HZ 60 PHASE 3 FRAME 326T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 30 VOLTS 460 RPM 900 TYPE RGZESD
HZ 60 PHASE 3 FRAME 364T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
50%
100%
150%
200%
250%
300%
350%
400%
450%
500%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 40 VOLTS 460 RPM 3600 TYPE RGZESD
HZ 60 PHASE 3 FRAME 324TS NEMA B
Customer: PO No.: Order No.:
TORQUE AND CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 40 VOLTS 460 RPM 1800 TYPE RGZESD
HZ 60 PHASE 3 FRAME 324T NEMA B
Customer: PO No.: Order No.:
TORQUE AND CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 40 VOLTS 460 RPM 1200 TYPE RGZESD
HZ 60 PHASE 3 FRAME 364T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 40 VOLTS 460 RPM 900 TYPE RGZESD
HZ 60 PHASE 3 FRAME 365T NEMA B
Customer: PO No.: Order No.:
TORQUE AND CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
50%
100%
150%
200%
250%
300%
350%
400%
450%
500%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 50 VOLTS 460 RPM 3600 TYPE RGZESD
HZ 60 PHASE 3 FRAME 326TS NEMA B
Customer: PO No.: Order No.:
TORQUE AND CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 50 VOLTS 460 RPM 1800 TYPE RGZESD
HZ 60 PHASE 3 FRAME 326T NEMA B
Customer: PO No.: Order No.:
TORQUE AND CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 50 VOLTS 460 RPM 1200 TYPE RGZESD
HZ 60 PHASE 3 FRAME 365T NEMA B
Customer: PO No.: Order No.:
TORQUE AND CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 50 VOLTS 460 RPM 900 TYPE RGZESD
HZ 60 PHASE 3 FRAME 404T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 60 VOLTS 460 RPM 3600 TYPE RGZESD
HZ 60 PHASE 3 FRAME 364TS NEMA B
Customer: PO No.: Order No.:
TORQUE AND CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 60 VOLTS 460 RPM 1800 TYPE RGZESD
HZ 60 PHASE 3 FRAME 364T NEMA B
Customer: PO No.: Order No.:
TORQUE AND CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 60 VOLTS 460 RPM 1200 TYPE RGZESD
HZ 60 PHASE 3 FRAME 404T NEMA B
Customer: PO No.: Order No.:
TORQUE AND CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 60 VOLTS 460 RPM 900 TYPE RGZESD
HZ 60 PHASE 3 FRAME 405T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 75 VOLTS 460 RPM 3600 TYPE RGZESD
HZ 60 PHASE 3 FRAME 365TS NEMA B
Customer: PO No.: Order No.:
TORQUE AND CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 75 VOLTS 460 RPM 1800 TYPE RGZESD
HZ 60 PHASE 3 FRAME 365T NEMA B
Customer: PO No.: Order No.:
TORQUE AND CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 75 VOLTS 460 RPM 1200 TYPE RGZESD
HZ 60 PHASE 3 FRAME 405T NEMA B
Customer: PO No.: Order No.:
TORQUE AND CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 75 VOLTS 460 RPM 900 TYPE RGZESD
HZ 60 PHASE 3 FRAME 444T NEMA B
Customer: PO No.: Order No.:
TORQUE AND CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 100 VOLTS 460 RPM 3600 TYPE RGZESD
HZ 60 PHASE 3 FRAME 405TS NEMA B
Customer: PO No.: Order No.:
TORQUE AND CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
800%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 100 VOLTS 460 RPM 1800 TYPE RGZESD
HZ 60 PHASE 3 FRAME 405T NEMA B
Customer: PO No.: Order No.:
TORQUE AND CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 100 VOLTS 460 RPM 1200 TYPE RGZESD
HZ 60 PHASE 3 FRAME 444TS NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 100 VOLTS 460 RPM 900 TYPE RGZESD
HZ 60 PHASE 3 FRAME 445T NEMA B
Customer: PO No.: Order No.:
TORQUE AND CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 125 VOLTS 460 RPM 3600 TYPE RGZESD
HZ 60 PHASE 3 FRAME 444TS NEMA B
Customer: PO No.: Order No.:
TORQUE AND CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
% F
ULL
LO
AD
CU
RR
ENTTORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 125 VOLTS 460 RPM 1800 TYPE RGZESD
HZ 60 PHASE 3 FRAME 444T NEMA B
Customer: PO No.: Order No.:
TORQUE AND CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 125 VOLTS 460 RPM 1200 TYPE RGZESD
HZ 60 PHASE 3 FRAME 445T NEMA B
Customer: PO No.: Order No.:
TORQUE AND CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 125 VOLTS 460 RPM 900 TYPE RGZESD
HZ 60 PHASE 3 FRAME 447T NEMA B
Customer: PO No.: Order No.:
TORQUE AND CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 150 VOLTS 460 RPM 3600 TYPE RGZESD
HZ 60 PHASE 3 FRAME 445TS NEMA B
Customer: PO No.: Order No.:
TORQUE AND CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 150 VOLTS 460 RPM 1800 TYPE RGZESD
HZ 60 PHASE 3 FRAME 445T NEMA B
Customer: PO No.: Order No.:
TORQUE AND CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 150 VOLTS 460 RPM 1200 TYPE RGZESD
HZ 60 PHASE 3 FRAME 447T NEMA B
Customer: PO No.: Order No.:
TORQUE AND CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
% F
ULL
LO
AD
CU
RR
ENTTORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 150 VOLTS 460 RPM 900 TYPE RGZESD
HZ 60 PHASE 3 FRAME 447T NEMA B
Customer: PO No.: Order No.:
TORQUE AND CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 200 VOLTS 460 RPM 3600 TYPE RGZESD
HZ 60 PHASE 3 FRAME 447TS NEMA B
Customer: PO No.: Order No.:
TORQUE AND CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
800%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 200 VOLTS 460 RPM 1800 TYPE RGZESD
HZ 60 PHASE 3 FRAME 447T NEMA B
Customer: PO No.: Order No.:
TORQUE AND CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 200 VOLTS 460 RPM 1200 TYPE RGZESD
HZ 60 PHASE 3 FRAME 449T NEMA B
Customer: PO No.: Order No.:
TORQUE AND CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 200 VOLTS 460 RPM 900 TYPE RGZESD
HZ 60 PHASE 3 FRAME 449T NEMA B
Customer: PO No.: Order No.:
TORQUE AND CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.MOTORS & DRIVES DIVISION
HP 250 VOLTS 460 RPM 3600 TYPE RGZESD
HZ 60 PHASE 3 FRAME 449TS NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
800%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.MOTORS & DRIVES DIVISION
HP 250 VOLTS 460 RPM 1800 TYPE RGZESD
HZ 60 PHASE 3 FRAME 449TS NEMA B
Customer: PO No.: Order No.:
TORQUE VS. SPEED
0%
50%
100%
150%
200%
250%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
TORQUE
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.MOTORS & DRIVES DIVISION
HP 250 VOLTS 460 RPM 1200 TYPE RGZESD
HZ 60 PHASE 3 FRAME 449TS NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.MOTORS & DRIVES DIVISION
HP 200 VOLTS 460 RPM 900 TYPE RGZESD
HZ 60 PHASE 3 FRAME S449 NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.MOTORS & DRIVES DIVISION
HP 300 VOLTS 460 RPM 3600 TYPE RGZESD
HZ 60 PHASE 3 FRAME 449TS NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
800%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.MOTORS & DRIVES DIVISION
HP 300 VOLTS 460 RPM 1800 TYPE RGZESD
HZ 60 PHASE 3 FRAME 449TS NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.MOTORS & DRIVES DIVISION
HP 300 VOLTS 460 RPM 1200 TYPE RGZESD
HZ 60 PHASE 3 FRAME S449 NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.MOTORS & DRIVES DIVISION
HP 300 VOLTS 460 RPM 1800 TYPE RGZESD
HZ 60 PHASE 3 FRAME S449SS NEMA B
Customer: PO No.: Order No.:
TORQUE VS. SPEED
0%
50%
100%
150%
200%
250%
300%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
TORQUE
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.MOTORS & DRIVES DIVISION
HP 350 VOLTS 460 RPM 3600 TYPE RGZESD
HZ 60 PHASE 3 FRAME S449SS NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
800%
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.MOTORS & DRIVES DIVISION
HP 350 VOLTS 460 RPM 1800 TYPE RGZESD
HZ 60 PHASE 3 FRAME S449 NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
CUSTOMER: ______________________ PO#: ______________________ ORDER#: ______________________
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.MOTORS & DRIVES DIVISION
HP 350 VOLTS 460 RPM 1200 TYPE RGZESD
HZ 60 PHASE 3 FRAME S449 NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.MOTORS & DRIVES DIVISION
HP 400 VOLTS 460 RPM 3600 TYPE RGZESD
HZ 60 PHASE 3 FRAME S449SS NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
800%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.MOTORS & DRIVES DIVISION
HP 400 VOLTS 460 RPM 1800 TYPE RGZESD
HZ 60 PHASE 3 FRAME S449 NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 1 VOLTS 230/460 RPM 1800 TYPE RGZP(SD)
HZ 60 PHASE 3 FRAME 143T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
350%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
800%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 1 VOLTS 230/460 RPM 1200 TYPE RGZP(SD)
HZ 60 PHASE 3 FRAME 145T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
350%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 1.5 VOLTS 230/460 RPM 3600 TYPE RGZP(SD)
HZ 60 PHASE 3 FRAME 143T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
350%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
800%
900%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 1.5 VOLTS 230/460 RPM 1800 TYPE RGZP(SD)
HZ 60 PHASE 3 FRAME 145T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
350%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
800%
900%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 1.5 VOLTS 230/460 RPM 1200 TYPE RGZP(SD)
HZ 60 PHASE 3 FRAME 182T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
350%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
800%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 2 VOLTS 230/460 RPM 3600 TYPE RGZP(SD)
HZ 60 PHASE 3 FRAME 145T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
350%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
800%
900%
1000%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 2 VOLTS 230/460 RPM 1800 TYPE RGZP(SD)
HZ 60 PHASE 3 FRAME 145T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
350%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
800%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 2 VOLTS 230/460 RPM 1200 TYPE RGZP(SD)
HZ 60 PHASE 3 FRAME 184T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
350%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
800%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 3 VOLTS 230/460 RPM 3600 TYPE RGZP(SD)
HZ 60 PHASE 3 FRAME 182T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
350%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
800%
900%
1000%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 3 VOLTS 230/460 RPM 1800 TYPE RGZP(SD)
HZ 60 PHASE 3 FRAME 182T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
350%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
800%
900%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 3 VOLTS 230/460 RPM 1200 TYPE RGZP(SD)
HZ 60 PHASE 3 FRAME 213T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
350%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
800%
900%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 5 VOLTS 230/460 RPM 3600 TYPE RGZP(SD)
HZ 60 PHASE 3 FRAME 184T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
350%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
800%
900%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 5 VOLTS 230/460 RPM 1800 TYPE RGZP(SD)
HZ 60 PHASE 3 FRAME 184T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
350%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
800%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 5 VOLTS 230/460 RPM 1200 TYPE RGZP(SD)
HZ 60 PHASE 3 FRAME 215T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
350%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 7.5 VOLTS 230/460 RPM 1200 TYPE RGZP(SD)
HZ 60 PHASE 3 FRAME 254T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 7.5 VOLTS 230/460 RPM 3600 TYPE RGZP(SD)
HZ 60 PHASE 3 FRAME 213T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
800%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 7.5 VOLTS 230/460 RPM 1800 TYPE RGZP(SD)
HZ 60 PHASE 3 FRAME 213T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
800%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 10 VOLTS 230/460 RPM 3600 TYPE RGZP(SD)
HZ 60 PHASE 3 FRAME 215T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
800%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 10 VOLTS 230/460 RPM 1800 TYPE RGZP(SD)
HZ 60 PHASE 3 FRAME 215T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 10 VOLTS 230/460 RPM 1200 TYPE RGZP(SD)
HZ 60 PHASE 3 FRAME 256T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 15 VOLTS 230/460 RPM 3600 TYPE RGZP(SD)
HZ 60 PHASE 3 FRAME 254T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
800%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 15 VOLTS 230/460 RPM 1800 TYPE RGZPSD
HZ 60 PHASE 3 FRAME 254T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 15 VOLTS 230/460 RPM 1200 TYPE RGZP(SD)
HZ 60 PHASE 3 FRAME 284T NEMA B
Customer: PO No.: Order No.:
TORQUE AND CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 20 VOLTS 230/460 RPM 3600 TYPE RGZP(SD)
HZ 60 PHASE 3 FRAME 256T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 20 VOLTS 230/460 RPM 1800 TYPE RGZP(SD)
HZ 60 PHASE 3 FRAME 256T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 20 VOLTS 230/460 RPM 1200 TYPE RGZP(SD)
HZ 60 PHASE 3 FRAME 286T NEMA B
Customer: PO No.: Order No.:
TORQUE AND CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 25 VOLTS 460 RPM 3600 TYPE RGZP(SD)
HZ 60 PHASE 3 FRAME 284TS NEMA B
Customer: PO No.: Order No.:
TORQUE AND CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 25 VOLTS 460 RPM 1800 TYPE RGZP(SD)
HZ 60 PHASE 3 FRAME 284T NEMA B
Customer: PO No.: Order No.:
TORQUE AND CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 25 VOLTS 460 RPM 1200 TYPE RGZP(SD)
HZ 60 PHASE 3 FRAME 324T NEMA B
Customer: PO No.: Order No.:
TORQUE AND CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
% F
ULL
LO
AD
CU
RR
ENTTORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 30 VOLTS 460 RPM 3600 TYPE RGZP(SD)
HZ 60 PHASE 3 FRAME 286TS NEMA B
Customer: PO No.: Order No.:
TORQUE AND CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 30 VOLTS 460 RPM 1800 TYPE RGZP(SD)
HZ 60 PHASE 3 FRAME 286T NEMA B
Customer: PO No.: Order No.:
TORQUE AND CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 30 VOLTS 460 RPM 1200 TYPE RGZP(SD)
HZ 60 PHASE 3 FRAME 326T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 40 VOLTS 460 RPM 3600 TYPE RGZP(SD)
HZ 60 PHASE 3 FRAME 324TS NEMA B
Customer: PO No.: Order No.:
TORQUE AND CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 40 VOLTS 460 RPM 1800 TYPE RGZP(SD)
HZ 60 PHASE 3 FRAME 324T NEMA B
Customer: PO No.: Order No.:
TORQUE AND CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 40 VOLTS 460 RPM 1200 TYPE RGZP(SD)
HZ 60 PHASE 3 FRAME 364T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 50 VOLTS 460 RPM 3600 TYPE RGZP(SD)
HZ 60 PHASE 3 FRAME 326TS NEMA B
Customer: PO No.: Order No.:
TORQUE AND CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 50 VOLTS 460 RPM 1800 TYPE RGZP(SD)
HZ 60 PHASE 3 FRAME 326T NEMA B
Customer: PO No.: Order No.:
TORQUE AND CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 50 VOLTS 460 RPM 1200 TYPE RGZP(SD)
HZ 60 PHASE 3 FRAME 365T NEMA B
Customer: PO No.: Order No.:
TORQUE AND CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 60 VOLTS 460 RPM 3600 TYPE RGZP(SD)
HZ 60 PHASE 3 FRAME 364TS NEMA B
Customer: PO No.: Order No.:
TORQUE AND CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 60 VOLTS 460 RPM 1800 TYPE RGZP(SD)
HZ 60 PHASE 3 FRAME 364T NEMA B
Customer: PO No.: Order No.:
TORQUE AND CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 60 VOLTS 460 RPM 1200 TYPE RGZP(SD)
HZ 60 PHASE 3 FRAME 404T NEMA B
Customer: PO No.: Order No.:
TORQUE AND CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 75 VOLTS 460 RPM 3600 TYPE RGZP(SD)
HZ 60 PHASE 3 FRAME 365TS NEMA B
Customer: PO No.: Order No.:
TORQUE AND CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 75 VOLTS 460 RPM 1800 TYPE RGZP(SD)
HZ 60 PHASE 3 FRAME 365T NEMA B
Customer: PO No.: Order No.:
TORQUE AND CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 75 VOLTS 460 RPM 1200 TYPE RGZP(SD)
HZ 60 PHASE 3 FRAME 405T NEMA B
Customer: PO No.: Order No.:
TORQUE AND CURRENT VS. SPEED
0%
100%
200%
300%
400%
500%
600%
700%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
50%
100%
150%
200%
250%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 100 VOLTS 460 RPM 3600 TYPE RGZP(SD)
HZ 60 PHASE 3 FRAME 405TS NEMA B
Customer: PO No.: Order No.:
TORQUE AND CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 100 VOLTS 460 RPM 1800 TYPE RGZP(SD)
HZ 60 PHASE 3 FRAME 405T NEMA B
Customer: PO No.: Order No.:
TORQUE AND CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 100 VOLTS 460 RPM 1200 TYPE RGZP(SD)
HZ 60 PHASE 3 FRAME 444TS NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 125 VOLTS 460 RPM 3600 TYPE RGZP(SD)
HZ 60 PHASE 3 FRAME 444TS NEMA B
Customer: PO No.: Order No.:
TORQUE AND CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
% F
ULL
LO
AD
CU
RR
ENTTORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 125 VOLTS 460 RPM 1800 TYPE RGZP(SD)
HZ 60 PHASE 3 FRAME 444T NEMA B
Customer: PO No.: Order No.:
TORQUE AND CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 125 VOLTS 460 RPM 1200 TYPE RGZP(SD)
HZ 60 PHASE 3 FRAME 445T NEMA B
Customer: PO No.: Order No.:
TORQUE AND CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 150 VOLTS 460 RPM 3600 TYPE RGZP(SD)
HZ 60 PHASE 3 FRAME 445TS NEMA B
Customer: PO No.: Order No.:
TORQUE AND CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
% F
ULL
LO
AD
CU
RR
ENTTORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 150 VOLTS 460 RPM 1800 TYPE RGZP(SD)
HZ 60 PHASE 3 FRAME 445T NEMA B
Customer: PO No.: Order No.:
TORQUE AND CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 150 VOLTS 460 RPM 1200 TYPE RGZP(SD)
HZ 60 PHASE 3 FRAME 447T NEMA B
Customer: PO No.: Order No.:
TORQUE AND CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
% F
ULL
LO
AD
CU
RR
ENTTORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 200 VOLTS 460 RPM 3600 TYPE RGZPSD
HZ 60 PHASE 3 FRAME 447TS NEMA B
Customer: PO No.: Order No.:
TORQUE AND CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
800%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 200 VOLTS 460 RPM 1800 TYPE RGZP(SD)
HZ 60 PHASE 3 FRAME 447T NEMA B
Customer: PO No.: Order No.:
TORQUE AND CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 200 VOLTS 460 RPM 1200 TYPE RGZP(SD)
HZ 60 PHASE 3 FRAME 449T NEMA B
Customer: PO No.: Order No.:
TORQUE AND CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
% F
ULL
LO
AD
CU
RR
ENTTORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 1 VOLTS 230/460 RPM 1800 TYPE RGZZESD
HZ 60 PHASE 3 FRAME 143T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
350%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
800%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 1 VOLTS 230/460 RPM 1200 TYPE RGZZESD
HZ 60 PHASE 3 FRAME 145T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
350%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 1 VOLTS 230/460 RPM 900 TYPE RGZZESD
HZ 60 PHASE 3 FRAME 182T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
50%
100%
150%
200%
250%
300%
350%
400%
450%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 1.5 VOLTS 230/460 RPM 3600 TYPE RGZZESD
HZ 60 PHASE 3 FRAME 143T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
350%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
800%
900%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 1.5 VOLTS 230/460 RPM 1800 TYPE RGZZESD
HZ 60 PHASE 3 FRAME 145T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
350%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
800%
900%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 1.5 VOLTS 230/460 RPM 1200 TYPE RGZZESD
HZ 60 PHASE 3 FRAME 182T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
350%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
800%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 1.5 VOLTS 230/460 RPM 900 TYPE RGZZESD
HZ 60 PHASE 3 FRAME 184T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 2 VOLTS 230/460 RPM 3600 TYPE RGZZESD
HZ 60 PHASE 3 FRAME 145T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
350%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
800%
900%
1000%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 2 VOLTS 230/460 RPM 1800 TYPE RGZZESD
HZ 60 PHASE 3 FRAME 145T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
350%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
800%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 2 VOLTS 230/460 RPM 1200 TYPE RGZZESD
HZ 60 PHASE 3 FRAME 184T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
350%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
800%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 2 VOLTS 230/460 RPM 900 TYPE RGZZESD
HZ 60 PHASE 3 FRAME 213T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
350%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 3 VOLTS 230/460 RPM 3600 TYPE RGZZESD
HZ 60 PHASE 3 FRAME 182T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
350%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
800%
900%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 3 VOLTS 230/460 RPM 1800 TYPE RGZZESD
HZ 60 PHASE 3 FRAME 182T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
350%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
800%
900%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 3 VOLTS 230/460 RPM 1200 TYPE RGZZESD
HZ 60 PHASE 3 FRAME 213T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
350%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
800%
900%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 3 VOLTS 230/460 RPM 900 TYPE RGZZESD
HZ 60 PHASE 3 FRAME 215T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 5 VOLTS 230/460 RPM 3600 TYPE RGZZESD
HZ 60 PHASE 3 FRAME 184T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
350%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
800%
900%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 5 VOLTS 230/460 RPM 1800 TYPE RGZZESD
HZ 60 PHASE 3 FRAME 184T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
350%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
800%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 5 VOLTS 230/460 RPM 1200 TYPE RGZZESD
HZ 60 PHASE 3 FRAME 215T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
350%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
800%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 5 VOLTS 230/460 RPM 900 TYPE RGZZESD
HZ 60 PHASE 3 FRAME 254T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
% F
ULL
LO
AD
CU
RR
ENTTORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 7.5 VOLTS 230/460 RPM 3600 TYPE RGZZESD
HZ 60 PHASE 3 FRAME 213T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
800%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 7.5 VOLTS 230/460 RPM 1800 TYPE RGZZESD
HZ 60 PHASE 3 FRAME 213T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
800%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 7.5 VOLTS 230/460 RPM 1200 TYPE RGZZESD
HZ 60 PHASE 3 FRAME 254T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 7.5 VOLTS 230/460 RPM 900 TYPE RGZZESD
HZ 60 PHASE 3 FRAME 256T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 10 VOLTS 230/460 RPM 3600 TYPE RGZZESD
HZ 60 PHASE 3 FRAME 215T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
800%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 10 VOLTS 230/460 RPM 1800 TYPE RGZZESD
HZ 60 PHASE 3 FRAME 215T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 10 VOLTS 230/460 RPM 1200 TYPE RGZZESD
HZ 60 PHASE 3 FRAME 256T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 10 VOLTS 230/460 RPM 900 TYPE RGZZESD
HZ 60 PHASE 3 FRAME 284T NEMA B
Customer: PO No.: Order No.:
TORQUE AND CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
% F
ULL
LO
AD
CU
RR
ENTTORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 15 VOLTS 230/460 RPM 3600 TYPE RGZZESD
HZ 60 PHASE 3 FRAME 254T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
800%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 15 VOLTS 230/460 RPM 1800 TYPE RGZZESD
HZ 60 PHASE 3 FRAME 254T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 15 VOLTS 230/460 RPM 1200 TYPE RGZZESD
HZ 60 PHASE 3 FRAME 284T NEMA B
Customer: PO No.: Order No.:
TORQUE AND CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 15 VOLTS 230/460 RPM 900 TYPE RGZZESD
HZ 60 PHASE 3 FRAME 286T NEMA B
Customer: PO No.: Order No.:
TORQUE AND CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
% F
ULL
LO
AD
CU
RR
ENTTORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 20 VOLTS 230/460 RPM 3600 TYPE RGZZESD
HZ 60 PHASE 3 FRAME 256T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 20 VOLTS 230/460 RPM 1800 TYPE RGZZESD
HZ 60 PHASE 3 FRAME 256T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 20 VOLTS 230/460 RPM 1200 TYPE RGZZESD
HZ 60 PHASE 3 FRAME 286T NEMA B
Customer: PO No.: Order No.:
TORQUE AND CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 20 VOLTS 230/460 RPM 900 TYPE RGZZESD
HZ 60 PHASE 3 FRAME 324T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
50%
100%
150%
200%
250%
300%
350%
400%
450%
500%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 25 VOLTS 460 RPM 3600 TYPE RGZZESD
HZ 60 PHASE 3 FRAME 284TS NEMA B
Customer: PO No.: Order No.:
TORQUE AND CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 25 VOLTS 460 RPM 1800 TYPE RGZZESD
HZ 60 PHASE 3 FRAME 284T NEMA B
Customer: PO No.: Order No.:
TORQUE AND CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 25 VOLTS 460 RPM 1200 TYPE RGZZESD
HZ 60 PHASE 3 FRAME 324T NEMA B
Customer: PO No.: Order No.:
TORQUE AND CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
% F
ULL
LO
AD
CU
RR
ENTTORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 25 VOLTS 460 RPM 900 TYPE RGZZESD
HZ 60 PHASE 3 FRAME 326T NEMA B
Customer: PO No.: Order No.:
TORQUE AND CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
50%
100%
150%
200%
250%
300%
350%
400%
450%
500%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 30 VOLTS 460 RPM 3600 TYPE RGZZESD
HZ 60 PHASE 3 FRAME 286TS NEMA B
Customer: PO No.: Order No.:
TORQUE AND CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 30 VOLTS 460 RPM 1800 TYPE RGZZESD
HZ 60 PHASE 3 FRAME 286T NEMA B
Customer: PO No.: Order No.:
TORQUE AND CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 30 VOLTS 460 RPM 1200 TYPE RGZZESD
HZ 60 PHASE 3 FRAME 326T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 30 VOLTS 460 RPM 900 TYPE RGZZESD
HZ 60 PHASE 3 FRAME 364T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
50%
100%
150%
200%
250%
300%
350%
400%
450%
500%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 40 VOLTS 460 RPM 3600 TYPE RGZZESD
HZ 60 PHASE 3 FRAME 324TS NEMA B
Customer: PO No.: Order No.:
TORQUE AND CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 40 VOLTS 460 RPM 1800 TYPE RGZZESD
HZ 60 PHASE 3 FRAME 324T NEMA B
Customer: PO No.: Order No.:
TORQUE AND CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 40 VOLTS 460 RPM 1200 TYPE RGZESD
HZ 60 PHASE 3 FRAME 364T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 40 VOLTS 460 RPM 900 TYPE RGZZESD
HZ 60 PHASE 3 FRAME 365T NEMA B
Customer: PO No.: Order No.:
TORQUE AND CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
50%
100%
150%
200%
250%
300%
350%
400%
450%
500%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 50 VOLTS 460 RPM 3600 TYPE RGZZESD
HZ 60 PHASE 3 FRAME 326TS NEMA B
Customer: PO No.: Order No.:
TORQUE AND CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 50 VOLTS 460 RPM 1800 TYPE RGZZESD
HZ 60 PHASE 3 FRAME 326T NEMA B
Customer: PO No.: Order No.:
TORQUE AND CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 50 VOLTS 460 RPM 1200 TYPE RGZZESD
HZ 60 PHASE 3 FRAME 365T NEMA B
Customer: PO No.: Order No.:
TORQUE AND CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 50 VOLTS 460 RPM 900 TYPE RGZZESD
HZ 60 PHASE 3 FRAME 404T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 60 VOLTS 460 RPM 3600 TYPE RGZZESD
HZ 60 PHASE 3 FRAME 364TS NEMA B
Customer: PO No.: Order No.:
TORQUE AND CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 60 VOLTS 460 RPM 1800 TYPE RGZZESD
HZ 60 PHASE 3 FRAME 364T NEMA B
Customer: PO No.: Order No.:
TORQUE AND CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 60 VOLTS 460 RPM 1200 TYPE RGZZESD
HZ 60 PHASE 3 FRAME 404T NEMA B
Customer: PO No.: Order No.:
TORQUE AND CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 60 VOLTS 460 RPM 900 TYPE RGZZESD
HZ 60 PHASE 3 FRAME 405T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 75 VOLTS 460 RPM 3600 TYPE RGZZESD
HZ 60 PHASE 3 FRAME 365TS NEMA B
Customer: PO No.: Order No.:
TORQUE AND CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 75 VOLTS 460 RPM 1800 TYPE RGZZESD
HZ 60 PHASE 3 FRAME 365T NEMA B
Customer: PO No.: Order No.:
TORQUE AND CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 75 VOLTS 460 RPM 1200 TYPE RGZZESD
HZ 60 PHASE 3 FRAME 405T NEMA B
Customer: PO No.: Order No.:
TORQUE AND CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 75 VOLTS 460 RPM 900 TYPE RGZZESD
HZ 60 PHASE 3 FRAME 444T NEMA B
Customer: PO No.: Order No.:
TORQUE AND CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 100 VOLTS 460 RPM 3600 TYPE RGZZESD
HZ 60 PHASE 3 FRAME 405TS NEMA B
Customer: PO No.: Order No.:
TORQUE AND CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
800%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 100 VOLTS 460 RPM 1800 TYPE RGZZESD
HZ 60 PHASE 3 FRAME 405T NEMA B
Customer: PO No.: Order No.:
TORQUE AND CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 100 VOLTS 460 RPM 1200 TYPE RGZZESD
HZ 60 PHASE 3 FRAME 444TS NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 100 VOLTS 460 RPM 900 TYPE RGZZESD
HZ 60 PHASE 3 FRAME 445T NEMA B
Customer: PO No.: Order No.:
TORQUE AND CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 125 VOLTS 460 RPM 3600 TYPE RGZZESD
HZ 60 PHASE 3 FRAME 444TS NEMA B
Customer: PO No.: Order No.:
TORQUE AND CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
% F
ULL
LO
AD
CU
RR
ENTTORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 125 VOLTS 460 RPM 1800 TYPE RGZZESD
HZ 60 PHASE 3 FRAME 444T NEMA B
Customer: PO No.: Order No.:
TORQUE AND CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 125 VOLTS 460 RPM 1200 TYPE RGZZESD
HZ 60 PHASE 3 FRAME 445T NEMA B
Customer: PO No.: Order No.:
TORQUE AND CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 125 VOLTS 460 RPM 900 TYPE RGZZESD
HZ 60 PHASE 3 FRAME 447T NEMA B
Customer: PO No.: Order No.:
TORQUE AND CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 150 VOLTS 460 RPM 3600 TYPE RGZZESD
HZ 60 PHASE 3 FRAME 445TS NEMA B
Customer: PO No.: Order No.:
TORQUE AND CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 150 VOLTS 460 RPM 1800 TYPE RGZZESD
HZ 60 PHASE 3 FRAME 445T NEMA B
Customer: PO No.: Order No.:
TORQUE AND CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 150 VOLTS 460 RPM 1200 TYPE RGZZESD
HZ 60 PHASE 3 FRAME 447T NEMA B
Customer: PO No.: Order No.:
TORQUE AND CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
% F
ULL
LO
AD
CU
RR
ENTTORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 150 VOLTS 460 RPM 900 TYPE RGZZESD
HZ 60 PHASE 3 FRAME 447T NEMA B
Customer: PO No.: Order No.:
TORQUE AND CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 200 VOLTS 460 RPM 3600 TYPE RGZZESD
HZ 60 PHASE 3 FRAME 447TS NEMA B
Customer: PO No.: Order No.:
TORQUE AND CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
800%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 200 VOLTS 460 RPM 1800 TYPE RGZZESD
HZ 60 PHASE 3 FRAME 447T NEMA B
Customer: PO No.: Order No.:
TORQUE AND CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 200 VOLTS 460 RPM 1200 TYPE RGZZESD
HZ 60 PHASE 3 FRAME 449T NEMA B
Customer: PO No.: Order No.:
TORQUE AND CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 200 VOLTS 460 RPM 900 TYPE RGZZESD
HZ 60 PHASE 3 FRAME 449T NEMA B
Customer: PO No.: Order No.:
TORQUE AND CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.MOTORS & DRIVES DIVISION
HP 250 VOLTS 460 RPM 3600 TYPE RGZZESD
HZ 60 PHASE 3 FRAME 449TS NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
800%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.MOTORS & DRIVES DIVISION
HP 250 VOLTS 460 RPM 1800 TYPE RGZZESD
HZ 60 PHASE 3 FRAME 449TS NEMA B
Customer: PO No.: Order No.:
TORQUE VS. SPEED
0%
50%
100%
150%
200%
250%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
TORQUE
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.MOTORS & DRIVES DIVISION
HP 250 VOLTS 460 RPM 1200 TYPE RGZZESD
HZ 60 PHASE 3 FRAME 449TS NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.MOTORS & DRIVES DIVISION
HP 300 VOLTS 460 RPM 3600 TYPE RGZZESD
HZ 60 PHASE 3 FRAME 449TS NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
800%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.MOTORS & DRIVES DIVISION
HP 300 VOLTS 460 RPM 1800 TYPE RGZZESD
HZ 60 PHASE 3 FRAME 449TS NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 1.5 VOLTS 460 RPM 3600 TYPE SD10
HZ 60 PHASE 3 FRAME 182T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
350%
400%
450%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
800%
900%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 1.5 VOLTS 460 RPM 1800 TYPE SD10
HZ 60 PHASE 3 FRAME 145T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
350%
400%
450%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
800%
900%
1000%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 1.5 VOLTS 460 RPM 1200 TYPE SD10
HZ 60 PHASE 3 FRAME 182T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
350%
400%
450%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 1.5 VOLTS 460 RPM 900 TYPE SD10
HZ 60 PHASE 3 FRAME 184T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
350%
400%
450%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 1 VOLTS 460 RPM 3600 TYPE SD10
HZ 60 PHASE 3 FRAME 143T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
350%
400%
450%
500%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
800%
900%
1000%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 1 VOLTS 460 RPM 1800 TYPE SD10
HZ 60 PHASE 3 FRAME 143T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
350%
400%
450%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
800%
900%
1000%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 1 VOLTS 460 RPM 1200 TYPE SD10
HZ 60 PHASE 3 FRAME 145T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
350%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 1 VOLTS 460 RPM 900 TYPE SD10
HZ 60 PHASE 3 FRAME 182T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
50%
100%
150%
200%
250%
300%
350%
400%
450%
500%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 2 VOLTS 460 RPM 3600 TYPE SD10
HZ 60 PHASE 3 FRAME 145T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
350%
400%
450%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
800%
900%
1000%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 2 VOLTS 460 RPM 1800 TYPE SD10
HZ 60 PHASE 3 FRAME 145T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
350%
400%
450%
500%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
800%
900%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 2 VOLTS 460 RPM 1200 TYPE SD10
HZ 60 PHASE 3 FRAME 184T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURVE VS. SPEED
0%
50%
100%
150%
200%
250%
300%
350%
400%
450%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
800%
900%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 2 VOLTS 460 RPM 900 TYPE SD10
HZ 60 PHASE 3 FRAME 213T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
350%
400%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 3 VOLTS 460 RPM 3600 TYPE SD10
HZ 60 PHASE 3 FRAME 182T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
350%
400%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
800%
900%
1000%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 3 VOLTS 460 RPM 1800 TYPE SD10
HZ 60 PHASE 3 FRAME 182T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
350%
400%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
800%
900%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 3 VOLTS 460 RPM 1200 TYPE SD10
HZ 60 PHASE 3 FRAME 213T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
350%
400%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
800%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 3 VOLTS 460 RPM 900 TYPE SD10
HZ 60 PHASE 3 FRAME 215T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
350%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 5 VOLTS 460 RPM 3600 TYPE SD10
HZ 60 PHASE 3 FRAME 184T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
350%
400%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
800%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 5 VOLTS 460 RPM 1800 TYPE SD10
HZ 60 PHASE 3 FRAME 184T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
350%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
800%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 5 VOLTS 460 RPM 1200 TYPE SD10
HZ 60 PHASE 3 FRAME 215T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
350%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
800%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 5 VOLTS 460 RPM 900 TYPE SD10
HZ 60 PHASE 3 FRAME 254T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 7.5 VOLTS 460 RPM 3600 TYPE SD10
HZ 60 PHASE 3 FRAME 213T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
350%
400%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
800%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 7.5 VOLTS 460 RPM 1800 TYPE SD10
HZ 60 PHASE 3 FRAME 213T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
350%
400%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 7.5 VOLTS 460 RPM 1200 TYPE SD10
HZ 60 PHASE 3 FRAME 254T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 7.5 VOLTS 460 RPM 900 TYPE SD10
HZ 60 PHASE 3 FRAME 256T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 10 VOLTS 460 RPM 3600 TYPE SD10
HZ 60 PHASE 3 FRAME 215T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
350%
400%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
800%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 10 VOLTS 460 RPM 1800 TYPE SD10
HZ 60 PHASE 3 FRAME 215T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
350%
400%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 10 VOLTS 460 RPM 1200 TYPE SD10
HZ 60 PHASE 3 FRAME 256T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 15 VOLTS 460 RPM 3600 TYPE SD10
HZ 60 PHASE 3 FRAME 254T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
350%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 15 VOLTS 460 RPM 1800 TYPE SD10
HZ 60 PHASE 3 FRAME 254T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 20 VOLTS 460 RPM 3600 TYPE SD10
HZ 60 PHASE 3 FRAME 256T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 20 VOLTS 460 RPM 1800 TYPE SD10
HZ 60 PHASE 3 FRAME 256T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 1.5 VOLTS 460 RPM 3600 TYPE SD100
HZ 60 PHASE 3 FRAME 143T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
350%
400%
450%
500%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
200%
400%
600%
800%
1000%
1200%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 1.5 VOLTS 460 RPM 1800 TYPE SD100
HZ 60 PHASE 3 FRAME 145T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
350%
400%
450%
500%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
800%
900%
1000%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 1.5 VOLTS 460 RPM 1200 TYPE SD100
HZ 60 PHASE 3 FRAME 182T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
350%
400%
450%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
800%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 1 VOLTS 460 RPM 3600 TYPE SD100
HZ 60 PHASE 3 FRAME 143T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
350%
400%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 1 VOLTS 460 RPM 1800 TYPE SD100
HZ 60 PHASE 3 FRAME 143T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
350%
400%
450%
500%
550%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
200%
400%
600%
800%
1000%
1200%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 1 VOLTS 460 RPM 1200 TYPE SD100
HZ 60 PHASE 3 FRAME 145T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
350%
400%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
800%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 2 VOLTS 460 RPM 3600 TYPE SD100
HZ 60 PHASE 3 FRAME 145T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
350%
400%
450%
500%
550%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
200%
400%
600%
800%
1000%
1200%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 2 VOLTS 460 RPM 1800 TYPE SD100
HZ 60 PHASE 3 FRAME 145T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
350%
400%
450%
500%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
800%
900%
1000%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 2 VOLTS 460 RPM 1200 TYPE SD100
HZ 60 PHASE 3 FRAME 184T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
350%
400%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
800%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 3 VOLTS 460 RPM 3600 TYPE SD100
HZ 60 PHASE 3 FRAME 182T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
350%
400%
450%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
800%
900%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 3 VOLTS 460 RPM 1800 TYPE SD100
HZ 60 PHASE 3 FRAME 182T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
350%
400%
450%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
800%
900%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 3 VOLTS 460 RPM 1200 TYPE SD100
HZ 60 PHASE 3 FRAME 213T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
350%
400%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
800%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 5 VOLTS 460 RPM 3600 TYPE SD100
HZ 60 PHASE 3 FRAME 184T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
350%
400%
450%
500%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
800%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 5 VOLTS 460 RPM 1800 TYPE SD100
HZ 60 PHASE 3 FRAME 184T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
350%
400%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
800%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 5 VOLTS 460 RPM 1200 TYPE SD100
HZ 60 PHASE 3 FRAME 215T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
350%
400%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
800%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 7.5 VOLTS 460 RPM 3600 TYPE SD100
HZ 60 PHASE 3 FRAME 213T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
350%
400%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
800%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 7.5 VOLTS 460 RPM 1800 TYPE SD100
HZ 60 PHASE 3 FRAME 213T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
350%
400%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 7.5 VOLTS 460 RPM 1200 TYPE SD100
HZ 60 PHASE 3 FRAME 254T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 10 VOLTS 460 RPM 3600 TYPE SD100
HZ 60 PHASE 3 FRAME 215T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
350%
400%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
800%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 10 VOLTS 460 RPM 1800 TYPE SD100
HZ 60 PHASE 3 FRAME 215T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 10 VOLTS 460 RPM 1200 TYPE SD100
HZ 60 PHASE 3 FRAME 256T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 15 VOLTS 460 RPM 3600 TYPE SD100
HZ 60 PHASE 3 FRAME 254T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
350%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
800%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 15 VOLTS 460 RPM 1800 TYPE SD100
HZ 60 PHASE 3 FRAME 254T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
% F
ULL
L0A
D C
UR
REN
T
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 20 VOLTS 460 RPM 3600 TYPE SD100
HZ 60 PHASE 3 FRAME 256T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 20 VOLTS 460 RPM 1800 TYPE SD100
HZ 60 PHASE 3 FRAME 256T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 1.5 VOLTS 460 RPM 3600 TYPE SD100 IEEE-841
HZ 60 PHASE 3 FRAME 143T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
350%
400%
450%
500%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
200%
400%
600%
800%
1000%
1200%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 1.5 VOLTS 460 RPM 1800 TYPE SD100 IEEE-841
HZ 60 PHASE 3 FRAME 145T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
350%
400%
450%
500%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
800%
900%
1000%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 1.5 VOLTS 460 RPM 1200 TYPE SD100 IEEE-841
HZ 60 PHASE 3 FRAME 182T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
350%
400%
450%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
800%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 1 VOLTS 460 RPM 3600 TYPE SD100 IEEE-841
HZ 60 PHASE 3 FRAME 143T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
350%
400%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 1 VOLTS 460 RPM 1800 TYPE SD100 IEEE-841
HZ 60 PHASE 3 FRAME 143T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
350%
400%
450%
500%
550%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
200%
400%
600%
800%
1000%
1200%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 1 VOLTS 460 RPM 1200 TYPE SD100 IEEE-841
HZ 60 PHASE 3 FRAME 145T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
350%
400%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
800%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 2 VOLTS 460 RPM 3600 TYPE SD100 IEEE-841
HZ 60 PHASE 3 FRAME 145T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
350%
400%
450%
500%
550%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
200%
400%
600%
800%
1000%
1200%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 2 VOLTS 460 RPM 1800 TYPE SD100 IEEE-841
HZ 60 PHASE 3 FRAME 145T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
350%
400%
450%
500%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
800%
900%
1000%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 2 VOLTS 460 RPM 1200 TYPE SD100 IEEE-841
HZ 60 PHASE 3 FRAME 184T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
350%
400%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
800%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 3 VOLTS 460 RPM 3600 TYPE SD100 IEEE-841
HZ 60 PHASE 3 FRAME 182T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
350%
400%
450%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
800%
900%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 3 VOLTS 460 RPM 1800 TYPE SD100 IEEE-841
HZ 60 PHASE 3 FRAME 182T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
350%
400%
450%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
800%
900%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 3 VOLTS 460 RPM 1200 TYPE SD100 IEEE-841
HZ 60 PHASE 3 FRAME 213T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
350%
400%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
800%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 5 VOLTS 460 RPM 3600 TYPE SD100 IEEE-841
HZ 60 PHASE 3 FRAME 184T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
350%
400%
450%
500%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
800%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 5 VOLTS 460 RPM 1800 TYPE SD100 IEEE-841
HZ 60 PHASE 3 FRAME 184T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
350%
400%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
800%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 5 VOLTS 460 RPM 1200 TYPE SD100 IEEE-841
HZ 60 PHASE 3 FRAME 215T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
350%
400%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
800%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 7.5 VOLTS 460 RPM 3600 TYPE SD100 IEEE-841
HZ 60 PHASE 3 FRAME 213T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
350%
400%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
800%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 7.5 VOLTS 460 RPM 1800 TYPE SD100 IEEE-841
HZ 60 PHASE 3 FRAME 213T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
350%
400%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 7.5 VOLTS 460 RPM 1200 TYPE SD100 IEEE-841
HZ 60 PHASE 3 FRAME 254T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 10 VOLTS 460 RPM 3600 TYPE SD100 IEEE-841
HZ 60 PHASE 3 FRAME 215T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
350%
400%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
800%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 10 VOLTS 460 RPM 1800 TYPE SD100 IEEE-841
HZ 60 PHASE 3 FRAME 215T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 10 VOLTS 460 RPM 1200 TYPE SD100 IEEE-841
HZ 60 PHASE 3 FRAME 256T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 15 VOLTS 460 RPM 3600 TYPE SD100 IEEE-841
HZ 60 PHASE 3 FRAME 254T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
350%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
800%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 15 VOLTS 460 RPM 1800 TYPE SD100 IEEE-841
HZ 60 PHASE 3 FRAME 254T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
% F
ULL
L0A
D C
UR
REN
T
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 20 VOLTS 460 RPM 3600 TYPE SD100 IEEE-841
HZ 60 PHASE 3 FRAME 256T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
300%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2
SIEMENS ENERGY & AUTOMATION, INC.
HP 20 VOLTS 460 RPM 1800 TYPE SD100 IEEE-841
HZ 60 PHASE 3 FRAME 256T NEMA B
Customer: PO No.: Order No.:
TORQUE & CURRENT VS. SPEED
0%
50%
100%
150%
200%
250%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED
% F
ULL
LO
AD
TO
RQ
UE
0%
100%
200%
300%
400%
500%
600%
700%
% F
ULL
LO
AD
CU
RR
ENT
TORQUE
CURRENT
PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.REV. 1
Application Manual for NEMA Motors
Section 5Part 2