analysis of ozone concentrations in a dissipating tropical convective system during tc-4

1
Analysis of Ozone Concentrations in a Dissipating Tropical Convective System during TC-4 A.M. Bryan 1 , K. Obenour 1 , D. Slotke 1 , G.A. Morris 2 1 Dept. of Geography & Meteorology, Valparaiso University, Valparaiso, IN • 2 Dept. of Physics & Astronomy, Valparaiso University, Valparaiso, IN Abstract Project Overview Twenty-five balloon-borne ozonesondes were launched in Las Tablas, Panama during the period 13 July to 9 August 2007 as part of the NASA TC-4 field campaign. One sounding underwent four distinct convective undulations between the altitudes of 2 – 5 km over a period of 90 minutes during ascent, allowing the rare and unique opportunity for in situ analysis of temporal variations of ozone within a convective cell. Ozone concentrations within the convective layer steadily increased by 10 – 15 ppb, suggesting local production via lightning or convectively-influenced transport of ozone. The results PROJECT: DATE: LOCATION : FUNDED BY: Tropical Cloud Composition and Climate Coupling (TC4) July 17 – August 13, 2007 Las Tablas, Panamá (7.8°N, 80.3°W) NASA’s Office of Earth IN Space Grant Consortium Forcings Behind Undulations Figure 5 Undulations observed on 5 Aug 2007 are manifest in the altitude vs. time plotted above. The color codes distinguish the ascent portions of each sequential undulation as a reference for this study. Figure 6 The external vertical forcing (w) is isolated by removing the balloon lift via subtracting the mean rise rate of the non-undulating portions of the flight from the rise rate at each point. Downward vertical velocities of up to 8 ms -1 are measured. are compared with analogous cases where undulations were reported. Figure 1 Launching a balloon-borne ozonesonde unit in Las Tablas, Panamá during the NASA TC4 field campaign. Ozone Production Figure 10 The change in O 3 concentration with height is determined by subtracting the O 3 measured at given altitude by the O 3 at that same altitude in the previous undulation. dO 3 /dt is positive during the majority of the undulations, illustrating a local with time via production, Figure 9 The ozone profile for 5 Aug 2007 is shown above. Each ascent is color coded to match the ascent portions outlined in figure 5 to show the gradual increase in O 3 with time during each undulation between 2 – 5 km. A crude back-of-the-envelope calculation using the ideal gas law and ozone mixing ratio ~2×10 6 moles. Compare with lightning estimate below. Lightning is a major producer of O 3 via the production of NO x (Thompson et al. 1997). One flash of lightning produces an average of 1 × 10 27 molecules of O 3 (Minschwaner et al. 2008). Given the hourly- totaled lightning strikes within the relevant convective cell region (Figure 6), we can approximate the amount of O 3 produced via lightning in moles per hour (Table 1). Adler, R.F., and D.D. Fenn, 1979: Thunderstorm Vertical Velocities Estimated from Satellite Data. J. Atmos. Sci., 36, 1747–1754. Draxler, R.R. and Rolph, G.D., 2003. HYSPLIT (HYbrid Single-Particle Lagrangian Integrated Trajectory) Model access via NOAA ARL READY Website (http://www.arl.noaa.gov/ready/hysplit4.html). NOAA Air Resources Laboratory, Silver Spring, MD. Folkins, I., and R.V. Martin, 2005: The Vertical Structure of Tropical Convection and Its Impact on the Budgets of Water Vapor and Ozone. J. Atmos. Sci., 62, 1560–1573. Minschwaner K., L. E. Kalnajs, M. K. Dubey, L. M. Avallone, P. C. Sawaengphokai, H. E. Edens, W. P. Winn (2008), Observation of enhanced ozone in an electrically active storm over Socorro, NM: Implications for ozone production from corona discharges, J. Geophys. Res., 113, D17208, doi:10.1029/2007JD009500. Rolph, G.D., 2003. Real-time Environmental Applications and Display sYstem (READY) Website (http://www.arl.noaa.gov/ready/hysplit4.html). NOAA Air Resources Laboratory, Silver Spring, MD. Thompson, A.M., W.K. Tao, K.E. Pickering, J.R. Scala, and J. Simpson, 1997: Tropical Deep Convection and Ozone Formation. B. Am. Meteorol. Soc., 78, 1043–1054. Hr (UT) Stri kes O 3 Molecules O 3 (mol) 1200 165 1.65 × 10 29 2.70 × 10 5 1300 143 1.43 × 10 29 2.40 × 10 5 1400 77 7.70 × 10 28 1.30 × 10 5 1500 6 6.00 × 10 27 1.00 × 10 4 1600 0 0 0 1700 13 1.30 × 10 28 2.20 × 10 4 Total 404 4.04 × 10 29 6.72 × 10 5 Table 1 Lightning-induced O 3 production is quantified by approximating the total number of molecules of O 3 created given the hourly-totaled number of recorded lightning. These values are then converted to moles. (Below) Figure 11 Locations of lightning strikes detected within the hour of 1200 1300 UT. The turquoise balloon (centered) is the launch location of the ozonesonde. The cluster of strikes immediately to the east of the launch site were counted in the calculation in O 3 (Table 1). (Above) Production via Lightning Meteorological Conditions on 5 Aug 2007 Figure 4 Calculated vertical divergence (10 -4 s -1 ) based on gradients in the horizontal wind as measured by the NPOL radar. Vertical divergence can indicate locations with upward or downward vertical velocities. Figure 3 (R) Reflectivity from the NPOL radar (pictured above at right) at 1600 UT centered on Las Tablas, Panamá. The balloon is represented by the white circle at the center of the image. Figure 2 (L) A Skew-T Log-P diagram representation of the meteorological conditions recorded by the radiosonde unit attached on the 5 Aug 2007 ozonesonde flight package. The temperature and dew point profiles indicate that the vertical extent of the atmosphere is moist and conditionally unstable below 600 mb (4km). 25 Ozonesondes P, T, u, v, RH, O 3 • Daily at 1800 UT • Surface to ≈ 35 km Data available online: physics.valpo.edu/ozone/ tc4data.html Role of Water/Ice Accumulation on Balloon OBJECTIV E: Find the volume of ice or water required to make the buoyancy of the balloon neutral, assuming the balloon is a sphere. GIVEN VARIABLES: Balloon upward force: 2.2 kg Radius of the balloon: 0.915 m Density of ice: ρ ≈ 917 kg m -3 Surface area of balloon ≈ 10.52 m 2 Volume of balloon ≈ 2.4 × 10 3 m 2 DERIVED VARIABLES: Acknowledgments & References Future Work Determine the thickness of ice or water on the balloon needed to achieve the volume of neutral buoyancy using the following derived equation for the change in radius for neutral buoyancy: V = 4 3 πr r ( ) 3 4 3 πr 3 r r r layer of water SOLUTION: Δr ≈ 0.2 mm Role of Convective Downdrafts Figure 7 This figure shows the relationship between the balloon vertical velocity and the ambient temperature. Color codes are associated with ascent and subsequent descent portions of the flight, as shown in Fig. 5 above. Figure 8 A schematic diagram of the structure of convective clouds in the troposphere. Vertical motions in these layers are dominated by in-cloud heating (ω c ), evaporative cooling (ω e ), and radiative cooling (ω r ). (Folkins and Martin 2004) While undulating, the vertical velocity of the balloon reached 8 m s -1 (Figure 6), which corresponds with the largest observed vertical velocity of 7.8 m s -1 from Alder and Fenn (1979) for shallow tropical convection. The predominantly negative vertical velocities observed in figure 6 signify downdrafts as the primary vertical forcing. This is consistent with the forcing implied by the location of Funding to support this work came from the NASA Division of Earth Science (TC-4 Mission). Thanks to D. Lutz, B. Taubman, A. Thompson, P. Kucsera, and K. Pickering for data used in this study, and to our hosts in Panama for supporting our work. 0.2 mm is a realistic thickness of water or ice condensed on the balloon, allowing the balloon to reach or surpass neutral buoyancy, supporting downward vertical motion. Figure 7 adds further support to the notion of condensed precipitation as a dominant force by the observation that the descent portions of each oscillation begins just above the freezing level. The time required for any accumulated precipitation to evaporate is justified by the time required for the phase change from ice to water preceding evaporation. •Comparative studies with similar cases to test the dependence of other meteorological influences related to location, time of year and further understand the current case. •Look at the rate of transition between ascent and descent within the undulations as an indicator of the influence of precipitation accumulation versus convective downdrafts. •Examine the potential influence of ground-level anthropogenic ozone based in Panama City that may have been entrained in the inflow current of the convective cell. Figure 12 The HYSPLIT back- trajectory (Draxler & Rolph, 2003; Rolph, 2003) shows the transport from the Gulf of Panamá. This justifies the increased ozone concentratio ns observed by the ozonesonde.

Upload: sumi

Post on 24-Feb-2016

29 views

Category:

Documents


0 download

DESCRIPTION

Analysis of Ozone Concentrations in a Dissipating Tropical Convective System during TC-4. A .M. Bryan 1 , K. Obenour 1 , D. Slotke 1 , G.A. Morris 2. - PowerPoint PPT Presentation

TRANSCRIPT

Page 1: Analysis of  Ozone Concentrations  in a  Dissipating Tropical Convective System during  TC-4

Analysis of Ozone Concentrations in a Dissipating Tropical Convective System during TC-4A.M. Bryan1, K. Obenour1, D. Slotke1, G.A. Morris2

1Dept. of Geography & Meteorology, Valparaiso University, Valparaiso, IN • 2Dept. of Physics & Astronomy, Valparaiso University, Valparaiso, IN

Abstract

Project Overview

Twenty-five balloon-borne ozonesondes were launched in Las Tablas, Panama during the period 13 July to 9 August 2007 as part of the NASA TC-4 field campaign. One sounding underwent four distinct convective undulations between the altitudes of 2 – 5 km over a period of 90 minutes during ascent, allowing the rare and unique opportunity for in situ analysis of temporal variations of ozone within a convective cell. Ozone concentrations within the convective layer steadily increased by 10 – 15 ppb, suggesting local production via lightning or convectively-influenced transport of ozone. The results

PROJECT:

DATE:LOCATION:

FUNDED BY:

Tropical Cloud Composition and Climate Coupling (TC4)July 17 – August 13, 2007Las Tablas, Panamá (7.8°N, 80.3°W)NASA’s Office of Earth ScienceIN Space Grant Consortium

Forcings Behind Undulations

Figure 5 Undulations observed on 5 Aug 2007 are manifest in the altitude vs. time plotted above. The color codes distinguish the ascent portions of each sequential undulation as a reference for this study.

Figure 6 The external vertical forcing (w) is isolated by removing the balloon lift via subtracting the mean rise rate of the non-undulating portions of the flight from the rise rate at each point. Downward vertical velocities of up to 8 ms-1 are measured.

are compared with analogous cases where undulations were reported.

Figure 1 Launching a balloon-borne ozonesonde unit in Las Tablas, Panamá during the NASA TC4 field campaign.

Ozone Production

Figure 10 The change in O3 concentration with height is determined by subtracting the O3 measured at given altitude by the O3 at that same altitude in the previous undulation. dO3/dt is positive during the majority of the undulations, illustrating a local increase in O3 with time via production, transport, or both.

Figure 9 The ozone profile for 5 Aug 2007 is shown above. Each ascent is color coded to match the ascent portions outlined in figure 5 to show the gradual increase in O3 with time during each undulation between 2 – 5 km. A crude back-of-the-envelope calculation using the ideal gas law and ozone mixing ratio changes suggests a total production of ~2×106 moles. Compare with lightning estimate below.

Lightning is a major producer of O3 via the production of NOx (Thompson et al. 1997). One flash of lightning produces an average of 1 × 1027 molecules of O3 (Minschwaner et al. 2008). Given the hourly-totaled lightning strikes within the relevant convective cell region (Figure 6), we can approximate the amount of O3 produced via lightning in moles per hour (Table 1).

Adler, R.F., and D.D. Fenn, 1979: Thunderstorm Vertical Velocities Estimated from Satellite Data. J. Atmos. Sci., 36, 1747–1754.

Draxler, R.R. and Rolph, G.D., 2003. HYSPLIT (HYbrid Single-Particle Lagrangian Integrated Trajectory) Model access via NOAA ARL READY Website (http://www.arl.noaa.gov/ready/hysplit4.html). NOAA Air Resources Laboratory, Silver Spring, MD.

Folkins, I., and R.V. Martin, 2005: The Vertical Structure of Tropical Convection and Its Impact on the Budgets of Water Vapor and Ozone. J. Atmos. Sci., 62, 1560–1573.

Minschwaner K., L. E. Kalnajs, M. K. Dubey, L. M. Avallone, P. C. Sawaengphokai, H. E. Edens, W. P. Winn (2008), Observation of enhanced ozone in an electrically active storm over Socorro, NM: Implications for ozone production from corona discharges, J. Geophys. Res., 113, D17208, doi:10.1029/2007JD009500.

Rolph, G.D., 2003. Real-time Environmental Applications and Display sYstem (READY) Website (http://www.arl.noaa.gov/ready/hysplit4.html). NOAA Air Resources Laboratory, Silver Spring, MD.

Thompson, A.M., W.K. Tao, K.E. Pickering, J.R. Scala, and J. Simpson, 1997: Tropical Deep Convection and Ozone Formation. B. Am. Meteorol. Soc., 78, 1043–1054.

Hr (UT) Strikes O3 Molecules O3 (mol)

1200 165 1.65 × 1029 2.70 × 105

1300 143 1.43 × 1029 2.40 × 105

1400 77 7.70 × 1028 1.30 × 105

1500 6 6.00 × 1027 1.00 × 104

1600 0 0 01700 13 1.30 × 1028 2.20 × 104

Total 404 4.04 × 1029 6.72 × 105

Table 1 Lightning-induced O3 production is quantified by approximating the total number of molecules of O3 created given the hourly-totaled number of recorded lightning. These values are then converted to moles. (Below)

Figure 11 Locations of lightning strikes detected within the hour of 1200 – 1300 UT. The turquoise balloon (centered) is the launch location of the ozonesonde. The cluster of strikes immediately to the east of the launch site were counted in the calculation in O3 (Table 1). (Above)

Production via Lightning

Meteorological Conditions on 5 Aug 2007

Figure 4 Calculated vertical divergence (10-4 s-1) based on gradients in the horizontal wind as measured by the NPOL radar. Vertical divergence can indicate locations with upward or downward vertical velocities.

Figure 3 (R) Reflectivity from the NPOL radar (pictured above at right) at 1600 UT centered on Las Tablas, Panamá. The balloon is represented by the white circle at the center of the image.

Figure 2 (L) A Skew-T Log-P diagram representation of the meteorological conditions recorded by the radiosonde unit attached on the 5 Aug 2007 ozonesonde flight package. The temperature and dew point profiles indicate that the vertical extent of the atmosphere is moist and conditionally unstable below 600 mb (4km).

25 Ozonesondes• P, T, u, v, RH, O3

• Daily at 1800 UT• Surface to ≈ 35 km• Data available online:physics.valpo.edu/ozone/tc4data.html

Role of Water/Ice Accumulation on BalloonOBJECTIVE: Find the volume of ice or water required to make the buoyancy of the

balloon neutral, assuming the balloon is a sphere.

GIVEN VARIABLES:Balloon upward force: 2.2 kgRadius of the balloon: 0.915 mDensity of ice: ρ ≈ 917 kg m-3

Surface area of balloon ≈ 10.52 m2

Volume of balloon ≈ 2.4 × 103 m2

DERIVED VARIABLES:

Acknowledgments & References

Future Work

Determine the thickness of ice or water on the balloon needed to achieve the volume of neutral buoyancy using the following derived equation for the change in radius for neutral buoyancy:

V = 43π r + Δr( )

3 − 43πr3

r + Δr

r

layer of water

SOLUTION: Δr ≈ 0.2 mm

Role of Convective Downdrafts

Figure 7 This figure shows the relationship between the balloon vertical velocity and the ambient temperature. Color codes are associated with ascent and subsequent descent portions of the flight, as shown in Fig. 5 above.

Figure 8 A schematic diagram of the structure of convective clouds in the troposphere. Vertical motions in these layers are dominated by in-cloud heating (ωc), evaporative cooling (ωe), and radiative cooling (ωr). (Folkins and Martin 2004)

While undulating, the vertical velocity of the balloon reached 8 m s-1 (Figure 6), which corresponds with the largest observed vertical velocity of 7.8 m s-1 from Alder and Fenn (1979) for shallow tropical convection. The predominantly negative vertical velocities observed in figure 6 signify downdrafts as the primary vertical forcing. This is consistent with the forcing implied by the location of the balloon relative to the downdraft region associated with the shallow outflow layer (figure 8) of the convective cell (figure 3).

Funding to support this work came from the NASA Division of Earth Science (TC-4 Mission). Thanks to D. Lutz, B. Taubman, A. Thompson, P. Kucsera, and K. Pickering for data used in this study, and to our hosts in Panama for supporting our work.

0.2 mm is a realistic thickness of water or ice condensed on the balloon, allowing the balloon to reach or surpass neutral buoyancy, supporting downward vertical motion. Figure 7 adds further support to the notion of condensed precipitation as a dominant force by the observation that the descent portions of each oscillation begins just above the freezing level. The time required for any accumulated precipitation to evaporate is justified by the time required for the phase change from ice to water preceding evaporation.

• Comparative studies with similar cases to test the dependence of other meteorological influences related to location, time of year and further understand the current case.• Look at the rate of transition between ascent and descent within the undulations as an

indicator of the influence of precipitation accumulation versus convective downdrafts.• Examine the potential influence of ground-level anthropogenic ozone based in Panama

City that may have been entrained in the inflow current of the convective cell.

Figure 12 The HYSPLIT back-trajectory (Draxler & Rolph, 2003; Rolph, 2003) shows the transport from the Gulf of Panamá.This justifies the increased ozone concentrations observed by the ozonesonde.