Date: Certificate #: 1815848 Certificate of Calibration MICROPRECISION CALIBRATION INC. BATINO, CALAMBA CITY, LAGUNA, PHILS 4027 Lab # 935.05 +63495023015 BLOCK 2 LOT 4 CALAMBA PREMIERE INTERNATIONAL PARK 6/28/2012 IN TOLERANCE Site Location: MPC Lab. Uncertainty unit @ uin Customer: B2L4 CPIP, DPL TECH BUILDING MICRO PRECISION CALIBRATION INC. (PHIL.) MPC Control #: AN2250 Serial Number: 2907 Manufacturer: SIP SOCIETE GENEVOISE Model Number: SIP305M Gage Type: SUPERMICROMETER Received Condition: C Temp./RH: 20.7 52 Performed By: JOSEPH JACOB Cal. Interval: 12 MONTHS Cal. Due Date: June 27, 2013 Cal Date: June 27, 2012 Returned Condition: / Department: MECHANICAL LAB Work Order: Asset ID: AN2250 Size: 0~12 IN % IN TOLERANCE N/A *Calibration Notes: CALAMBA CITY LAGUNA, PHILIPPINES, 4027 ° Tolerance - Description Standard Tolerance + As Found As Left Test Points Uncertainty UOM Result 16.0 18.0 Force Test 14.0 16.0 16.0 0.4 oz Pass 0.000000 0.000012 Anvil Flatness 0.000000 0.000000 0.000000 4 IN Pass 0.000000 0.000012 Spindle Face 0.000000 0.000000 0.000000 4 IN Pass 0.050000 0.050020 Length Accuracy 0.049980 0.050000 0.050000 2.9 in Pass 0.100000 0.100020 Length Accuracy 0.099980 0.100000 0.100000 2.9 in Pass 0.200000 0.200020 Length Accuracy 0.199980 0.200000 0.200000 2.9 in Pass 0.300000 0.300020 Length Accuracy 0.299980 0.300000 0.300000 2.9 in Pass 0.400000 0.400020 Length Accuracy 0.399980 0.400000 0.400000 2.9 in Pass 0.500000 0.500020 Length Accuracy 0.499980 0.500000 0.500000 2.9 in Pass 0.600000 0.600020 Length Accuracy 0.599980 0.600000 0.600000 2.9 in Pass 0.700000 0.700020 Length Accuracy 0.699980 0.700000 0.700000 2.9 in Pass 0.800000 0.800020 Length Accuracy 0.799980 0.800000 0.800000 2.93 in Pass 0.900000 0.900020 Length Accuracy 0.899980 0.900000 0.900000 2.97 in Pass 1.000000 1.000020 Length Accuracy 0.999980 1.000000 1.000000 2.97 in Pass Found conditions meet or exceed manufacturer specifications. Page 1 of 2 (CERT, Rev 0) Calibrating Technician: JOSEPH JACOB QC Approval: DANNY BOY B. BUTIAL Uncertainties have been estimated at a 95 percent confidence level (k=2). Services rendered comply with ISO 17025:2005, ISO 9001:2008, ANSI/NCSL Z540-1, MPC Quality Manual, MPC CSD and with customer purchase order instructions. Calibration cycles and resulting due dates were submitted/approved by the customer. Any number of factors may cause an instrument to drift out of tolerance before the next scheduled calibration. Recalibration cycles should be based on frequency of use, environmental conditions and customer's established systematic accuracy. The information on this report, pertains only to the instrument identified. All standards are traceable to the National Institute of Standards and Technology (NIST). Services rendered include proper manufacture's service instructions and are warranted for no less than (30) days. This report may not be reproduced in part or in whole without the prior written approval of the issuing MPC lab. Uncertainty Estimated at 4 to 1

Upload: rowel-magbanua

Post on 28-Apr-2015

34 views

Category:

Documents


6 download

DESCRIPTION

dfsdf

TRANSCRIPT

Page 1: AN2250 Super Micrometer

Date: Certificate #: 1815848

Certificate of Calibration

MICROPRECISION CALIBRATION INC.

BATINO, CALAMBA CITY, LAGUNA, PHILS 4027

Lab # 935.05

+63495023015

BLOCK 2 LOT 4 CALAMBA PREMIERE INTERNATIONAL PARK

6/28/2012

IN TOLERANCE

Site Location: MPC Lab.Uncertainty unit @ uin

Customer:

B2L4 CPIP, DPL TECH BUILDING

MICRO PRECISION CALIBRATION INC. (PHIL.)

MPC Control #: AN2250 Serial Number: 2907

Manufacturer: SIP SOCIETE GENEVOISEModel Number: SIP305M

Gage Type: SUPERMICROMETERReceived Condition:

CTemp./RH: 20.7 52

Performed By: JOSEPH JACOB

Cal. Interval: 12 MONTHSCal. Due Date: June 27, 2013

Cal Date: June 27, 2012Returned Condition:

/

Department: MECHANICAL LAB

Work Order:

Asset ID: AN2250

Size: 0~12 IN%

IN TOLERANCE

N/A

*Calibration Notes:

CALAMBA CITY LAGUNA, PHILIPPINES, 4027

°

Tolerance -Description Standard Tolerance + As Found As Left

Test Points

UncertaintyUOM Result

16.0 18.0Force Test 14.0 16.016.0 0.4oz Pass

0.000000 0.000012Anvil Flatness 0.000000 0.0000000.000000 4IN Pass

0.000000 0.000012Spindle Face 0.000000 0.0000000.000000 4IN Pass

0.050000 0.050020Length Accuracy 0.049980 0.0500000.050000 2.9in Pass

0.100000 0.100020Length Accuracy 0.099980 0.1000000.100000 2.9in Pass

0.200000 0.200020Length Accuracy 0.199980 0.2000000.200000 2.9in Pass

0.300000 0.300020Length Accuracy 0.299980 0.3000000.300000 2.9in Pass

0.400000 0.400020Length Accuracy 0.399980 0.4000000.400000 2.9in Pass

0.500000 0.500020Length Accuracy 0.499980 0.5000000.500000 2.9in Pass

0.600000 0.600020Length Accuracy 0.599980 0.6000000.600000 2.9in Pass

0.700000 0.700020Length Accuracy 0.699980 0.7000000.700000 2.9in Pass

0.800000 0.800020Length Accuracy 0.799980 0.8000000.800000 2.93in Pass

0.900000 0.900020Length Accuracy 0.899980 0.9000000.900000 2.97in Pass

1.000000 1.000020Length Accuracy 0.999980 1.0000001.000000 2.97in Pass

Found conditions meet or exceed manufacturer specifications.

Page 1 of 2 (CERT, Rev 0)

Calibrating Technician:

JOSEPH JACOB

QC Approval:

DANNY BOY B. BUTIAL

Uncertainties have been estimated at a 95 percent confidence level (k=2). Services rendered comply with ISO 17025:2005, ISO 9001:2008, ANSI/NCSL Z540-1, MPC Quality Manual, MPC CSD and with customer purchase orderinstructions.

Calibration cycles and resulting due dates were submitted/approved by the customer. Any number of factors may cause an instrument to drift out of tolerance before the next scheduled calibration. Recalibration cycles should bebased on frequency of use, environmental conditions and customer's established systematic accuracy. The information on this report, pertains only to the instrument identified.

All standards are traceable to the National Institute of Standards and Technology (NIST). Services rendered include proper manufacture's service instructions and are warranted for no less than (30) days. This report may not bereproduced in part or in whole without the prior written approval of the issuing MPC lab.

Uncertainty Estimated at 4 to 1

Page 2: AN2250 Super Micrometer

Date: Certificate #: 1815848

Certificate of Calibration

MICROPRECISION CALIBRATION INC.

BATINO, CALAMBA CITY, LAGUNA, PHILS 4027

Lab # 935.05

+63495023015

BLOCK 2 LOT 4 CALAMBA PREMIERE INTERNATIONAL PARK

6/28/2012

Tolerance -Description Standard Tolerance + As Found As Left

Test Points

UncertaintyUOM Result

9.000000 9.000020Length Accuracy 8.999980 9.0000009.000000 13in Pass

12.000000 12.000020Length Accuracy 11.999980 12.00000012.000000 17in Pass

Cal. Due DateI.D. Description Model

Standards Used To Calibrate Equipment

ManufacturerSerial Traceability #

AN2254 OPTICAL FLAT NONE 7/14/2012VAN KEUREN311 1700232507

AN2269 GAGE BLOCK SET, 7 PCS. GRADE 2 11/15/2013DEARBORN GAGE CO.NONE 1000307509

AS3936 GAGE BLOCK SET 81 PCS 30-910-4 5/8/2013SPI81PCS-6405 1000316956

AX2875 LOAD CELL INDICATOR PHM-100 2/22/2013TRANSDUCER TECHNIQUES192832 1306251

Procedure Name Description

Procedures Used In This Event:

33K6-4-145-1 STANDARD MEASURING MACHINE

Page 2 of 2 (CERT, Rev 0)

Calibrating Technician:

JOSEPH JACOB

QC Approval:

DANNY BOY B. BUTIAL

Uncertainties have been estimated at a 95 percent confidence level (k=2). Services rendered comply with ISO 17025:2005, ISO 9001:2008, ANSI/NCSL Z540-1, MPC Quality Manual, MPC CSD and with customer purchase orderinstructions.

Calibration cycles and resulting due dates were submitted/approved by the customer. Any number of factors may cause an instrument to drift out of tolerance before the next scheduled calibration. Recalibration cycles should bebased on frequency of use, environmental conditions and customer's established systematic accuracy. The information on this report, pertains only to the instrument identified.

All standards are traceable to the National Institute of Standards and Technology (NIST). Services rendered include proper manufacture's service instructions and are warranted for no less than (30) days. This report may not bereproduced in part or in whole without the prior written approval of the issuing MPC lab.

Uncertainty Estimated at 4 to 1