an overview of system & appliance testing a2z on-demand training
TRANSCRIPT
![Page 1: An Overview of System & Appliance Testing A2Z On-Demand Training](https://reader036.vdocuments.mx/reader036/viewer/2022062421/56649c7f5503460f94936010/html5/thumbnails/1.jpg)
An Overview ofSystem & Appliance Testing
A2Z On-Demand Training
![Page 2: An Overview of System & Appliance Testing A2Z On-Demand Training](https://reader036.vdocuments.mx/reader036/viewer/2022062421/56649c7f5503460f94936010/html5/thumbnails/2.jpg)
• Provide Back Feeding Overview
• Review Basic appliance testing guidelines
• Cover general steps of completing systems testing
Purpose:Purpose:
![Page 3: An Overview of System & Appliance Testing A2Z On-Demand Training](https://reader036.vdocuments.mx/reader036/viewer/2022062421/56649c7f5503460f94936010/html5/thumbnails/3.jpg)
Optimum Results:Optimum Results:
• Ensure basic understanding of the process
• We are able to provide accurate information to our clients
• Testing is completed safely
![Page 4: An Overview of System & Appliance Testing A2Z On-Demand Training](https://reader036.vdocuments.mx/reader036/viewer/2022062421/56649c7f5503460f94936010/html5/thumbnails/4.jpg)
Back Feeding OverviewBack Feeding Overview
![Page 5: An Overview of System & Appliance Testing A2Z On-Demand Training](https://reader036.vdocuments.mx/reader036/viewer/2022062421/56649c7f5503460f94936010/html5/thumbnails/5.jpg)
Back FeedingBack Feeding
• Supplying power in the opposite direction from its usual flow
• Electrical circuit gets energized normally
• Used for emergency power or testing purposes
• Listed as an exception in the NEC
![Page 6: An Overview of System & Appliance Testing A2Z On-Demand Training](https://reader036.vdocuments.mx/reader036/viewer/2022062421/56649c7f5503460f94936010/html5/thumbnails/6.jpg)
Reasons for Systems TestingReasons for Systems Testing
• Often required to give a simple assessment of the operation of appliances or parts of the electrical systems.
• Testing process will only give information as to whether certain parts of the system seem to operate correctly.
• Only a licensed HVAC technician or electrician can determine actual status.
![Page 7: An Overview of System & Appliance Testing A2Z On-Demand Training](https://reader036.vdocuments.mx/reader036/viewer/2022062421/56649c7f5503460f94936010/html5/thumbnails/7.jpg)
System Testing Requirements
A Brief Review
![Page 8: An Overview of System & Appliance Testing A2Z On-Demand Training](https://reader036.vdocuments.mx/reader036/viewer/2022062421/56649c7f5503460f94936010/html5/thumbnails/8.jpg)
Knowledge & TrainingKnowledge & Training
• You must completely understand what you are doing before you attempt to back feed electrical power.
• If you do not understand exactly the process involved DO NOT ATTEMPT to do an electrical systems test!
![Page 9: An Overview of System & Appliance Testing A2Z On-Demand Training](https://reader036.vdocuments.mx/reader036/viewer/2022062421/56649c7f5503460f94936010/html5/thumbnails/9.jpg)
Portable GeneratorPortable Generator
• The alternative power source that is used to do the electrical systems testing
• Needs to be fused to appropriate amperage for the system you are testing
• Needs to provide both 120V and 240V• Must typically be 5,000W-10,000W in order
to deal with the surge involved in powering up a standard heat pump or AC system.
![Page 10: An Overview of System & Appliance Testing A2Z On-Demand Training](https://reader036.vdocuments.mx/reader036/viewer/2022062421/56649c7f5503460f94936010/html5/thumbnails/10.jpg)
Cables & AttachmentsCables & Attachments
Extension Cables• Heavy duty extension cable• Long enough to reach the appliances to be
tested• Stock several different lengths
Adapter/Extension Cables• Used to interconnect the portable generator with
the housing power circuit• 240V electrical receptacle “block”
• Typically the stove/oven, or dryer
![Page 11: An Overview of System & Appliance Testing A2Z On-Demand Training](https://reader036.vdocuments.mx/reader036/viewer/2022062421/56649c7f5503460f94936010/html5/thumbnails/11.jpg)
240V plugs are distinct from normal 120V receptacles. This is a Standard 120V Receptacle
![Page 12: An Overview of System & Appliance Testing A2Z On-Demand Training](https://reader036.vdocuments.mx/reader036/viewer/2022062421/56649c7f5503460f94936010/html5/thumbnails/12.jpg)
3-Prong 240V Receptacle 4-Prong 240V Receptacle
![Page 13: An Overview of System & Appliance Testing A2Z On-Demand Training](https://reader036.vdocuments.mx/reader036/viewer/2022062421/56649c7f5503460f94936010/html5/thumbnails/13.jpg)
System Testing TypesSystem Testing Types
Individual Appliances/Systems• Plugged into the electrical system through
a receptacle:• refrigerators, stoves/ovens, some microwaves,
washers, dryers, free standing light fixtures, etc.
• Different plug configurations according to the voltage they require
• Extension cord from the generator directly to the component
![Page 14: An Overview of System & Appliance Testing A2Z On-Demand Training](https://reader036.vdocuments.mx/reader036/viewer/2022062421/56649c7f5503460f94936010/html5/thumbnails/14.jpg)
Wired Systems
• Appliances or system components that are not “plugged” into the circuit
• Permanently connected to the wiring system:• dishwashers, garbage disposals, electrical HVAC
components, light fixtures, ceiling fans, some smoke detectors, etc.
• Tested by back feeding power to the isolated power circuit, and individually testing each component
![Page 15: An Overview of System & Appliance Testing A2Z On-Demand Training](https://reader036.vdocuments.mx/reader036/viewer/2022062421/56649c7f5503460f94936010/html5/thumbnails/15.jpg)
Process ChecklistProcess Checklist
Before you begin…
![Page 16: An Overview of System & Appliance Testing A2Z On-Demand Training](https://reader036.vdocuments.mx/reader036/viewer/2022062421/56649c7f5503460f94936010/html5/thumbnails/16.jpg)
… … Answer These QuestionsAnswer These Questions
1. Are you sure that the main power is disconnected from the power grid?
2.Has the main switch been duct-taped into the off position?
4. Have all breaker switches in the main and all subpanels been turned to off?
5. Has the “In-Progress” warning sheet been posted on the main and all subpanels?
![Page 17: An Overview of System & Appliance Testing A2Z On-Demand Training](https://reader036.vdocuments.mx/reader036/viewer/2022062421/56649c7f5503460f94936010/html5/thumbnails/17.jpg)
6. Have all of your on-site personnel been grouped together and told to remain in the front yard until testing is complete?
7. Is the portable generator outside of the building in a well-ventilated area?
8. Is the generator off?
9. Are all switches in the house off and all appliances unplugged?
10. Are any external switches for the HVAC system off?
![Page 18: An Overview of System & Appliance Testing A2Z On-Demand Training](https://reader036.vdocuments.mx/reader036/viewer/2022062421/56649c7f5503460f94936010/html5/thumbnails/18.jpg)
11. Is the thermostat (or other heating switches) off?
12. Is the thermostat (or other heating switches) off?
13. Can you identify which switch is for the water heater?
14. Is there any standing water in the house?
15. Are there any smells of sulfur or natural gas anywhere around the building?
![Page 19: An Overview of System & Appliance Testing A2Z On-Demand Training](https://reader036.vdocuments.mx/reader036/viewer/2022062421/56649c7f5503460f94936010/html5/thumbnails/19.jpg)
16. Do you have all of your supplies (cables, adapters, etc.) ready and by the generator?
17. Is the main power disconnected and locked out?
18. IS THE MAIN POWER DISCONNECTED AND LOCKED OUT?
19. And finally...IS THE MAIN POWER DISCONNECTED AND LOCKED OUT?
![Page 20: An Overview of System & Appliance Testing A2Z On-Demand Training](https://reader036.vdocuments.mx/reader036/viewer/2022062421/56649c7f5503460f94936010/html5/thumbnails/20.jpg)
Once Your Checklist Is CompleteOnce Your Checklist Is Complete
Complete your testing• Consult the HUD Subcontractor Reference Manual
for recommended steps
Provide proper photo documentation• Warning Sheet Posted• Main in OFF position & duct taped• All breaker switches in OFF position• Generator outside• Back feed plugs in receptacle and attached to
generator
![Page 21: An Overview of System & Appliance Testing A2Z On-Demand Training](https://reader036.vdocuments.mx/reader036/viewer/2022062421/56649c7f5503460f94936010/html5/thumbnails/21.jpg)
Main Breaker ExamplesMain Breaker Examples
![Page 22: An Overview of System & Appliance Testing A2Z On-Demand Training](https://reader036.vdocuments.mx/reader036/viewer/2022062421/56649c7f5503460f94936010/html5/thumbnails/22.jpg)
Your safety is paramount. If you are not comfortable with
back feeding
DO NOT CONTINUE.
Return with someone who is comfortable OR a licensed electrician.
![Page 23: An Overview of System & Appliance Testing A2Z On-Demand Training](https://reader036.vdocuments.mx/reader036/viewer/2022062421/56649c7f5503460f94936010/html5/thumbnails/23.jpg)
Keys to Remember:Keys to Remember:• Follow all steps to ensure every safety
measure is taken• Provide photo documentation to support
your results• Consult the HUD Subcontractor
Reference Manual for recommended Back Feeding steps
• If you are unsure, walk away