an introduction to the bts-1000 (berd dawg) communications test set slide 1 of 22
TRANSCRIPT
AN INTRODUCTION TO THE BTS-1000 (BERD DAWG)
COMMUNICATIONS TEST SET
SLIDE 1 OF 22
This presentation is designed to give you an overview of all the keys, buttons, displays and other gadgets on the front panel of the Digital Interface in your BTS-1000 Test Set.
Please refer to your USER’S MANUAL for more information about any of the functions discussed here.
If you have any questions, please feel free to contact us at your convenience at [email protected], or 402-498-8400.
TO REVIEW WHAT YOU’VE DONE, SELECT THE KEY YOU’D LIKE TO SEE AGAIN:
MAIN SCREEN MAIN MENU DisplayFunction, Selection, Text Title, Screen #, Side # Circuit Status LinesRSD232 & DDS Ports OPTION CONTROL (Key Pad) Jack FieldDS1 RCV/XMT Keys FUNCTION KeysAUX ACCESS JacksHELP Key NEXT Key PREV KeyHOME Key
TO VIEW THIS PRESENTATION, USING PowerPoint, SELECT [View] AND [Slide Show]. USE YOUR COMPUTER [PAGE UP] OR [PAGE DOWN] KEYS, OR CLICK ANYWHERE ON THE SLIDE TO ADVANCE. THE [HOME] KEY WILL TAKE YOU TO THE FIRST SLIDE. THE [END] KEY WILL TAKE YOU TO THE LAST SLIDE.
SLIDE 2 OF 22
F6F5F4F3F2F1
DS0 DATA
RS-232 (DCE)RCV1 RCV2
DSX-MON
TERMBRIDGED
AUX ACCESS
POWER
OFF ON
SIDE 1
SIDE 2
DS1 ACCESS
XMTRCV
VF ACCESS
XMT E&MRCV 1ABC
2DEF
3STP
A
GHI4
JKL5
MNO6
ST2PB
PRS7
TUV8
WXY9
ST3PC
KP * 0
ST# D
CANCEL ENTER
HELP NEXT PREV HOME
VOLUME
BTS1000 (BERD DAWG) Interface
POWERStarts the whole thing!-Turns on power-Starts self diagnostics
POWERStarts the whole thing!-Turns on power-Starts self diagnostics
SLIDE 3 OF 22
F6F5F4F3F2F1
DS0 DATA
RS-232 (DCE)RCV1 RCV2
DSX-MON
TERMBRIDGED
AUX ACCESS
POWER
OFF ON
SIDE 1
SIDE 2
DS1 ACCESS
XMTRCV
VF ACCESS
XMT E&MRCV 1ABC
2DEF
3STP
A
GHI4
JKL5
MNO6
ST2PB
PRS7
TUV8
WXY9
ST3PC
KP * 0
ST# D
CANCEL ENTER
HELP NEXT PREV HOME
VOLUME
BTS1000 (BERD DAWG) Interface
MAIN SCREENThis screen or your CorporateLogo will appear at Power-ON,after the test set has run it’sself diagnostics.
Press any F key to go to theMAIN MENU.
SLIDE 4 OF 22
F6F5F4F3F2F1
DS0 DATA
RS-232 (DCE)RCV1 RCV2
DSX-MON
TERMBRIDGED
AUX ACCESS
POWER
OFF ON
SIDE 1
SIDE 2
DS1 ACCESS
XMTRCV
VF ACCESS
XMT E&MRCV 1ABC
2DEF
3STP
A
GHI4
JKL5
MNO6
ST2PB
PRS7
TUV8
WXY9
ST3PC
KP * 0
ST# D
CANCEL ENTER
HELP NEXT PREV HOME
VOLUME
BTS1000 (BERD DAWG) Interface
MAIN MENUAll tests start at the MAIN MENU.
Press HELP here to view calibration dates, options installed, software version and the Serial Number for this test set.
SLIDE 5 OF 22
F6F5F4F3F2F1
DS0 DATA
RS-232 (DCE)RCV1 RCV2
DSX-MON
TERMBRIDGED
AUX ACCESS
POWER
OFF ON
SIDE 1
SIDE 2
DS1 ACCESS
XMTRCV
VF ACCESS
XMT E&MRCV 1ABC
2DEF
3STP
A
GHI4
JKL5
MNO6
ST2PB
PRS7
TUV8
WXY9
ST3PC
KP * 0
ST# D
CANCEL ENTER
HELP NEXT PREV HOME
VOLUME
BTS1000 (BERD DAWG) Interface
DISPLAY SCREENShows set up options and status, and results of tests.
Move to the next slide for more information about this screen.
SLIDE 6 OF 22
BTS-1000MAIN DISPLAY SCREEN
FUNCTION KEYSThese are Menu selection key indicators. When these keys are displayed with boxes around them they are functional, regardless of screen type (SET-UP, RESULT or CONFIGuration) and the displayed location of the keys, the operation is as defined in the HELP screen text.
Selection text follows to the right of each key.
When a selection is made with the function key, a box is drawn around the selection.
SLIDE 7 OF 22
BTS-1000MAIN DISPLAY SCREEN
TITLEThe text that appears in the title location always refers to the Main Menu selection and if this is a SET-UP, RESULT, or CONFIGuration screen.
SIDE NUMBERThe SIDE NUMBER refers to DS1 RCV1 or DS1 RCV2. If SIDE ONE is showing, selections and test results are related to the DS1 RCV1 input.
SCREEN NUMBERThis number allows the user to track the selected screen’s position within the total number of SETUP or RESULT screens. SETUP screens always precede RESULT screens. Use the NEXT [NXT] and PREVious [PRV] keys to select the next or previous screen.
SLIDE 8 OF 22
BTS-1000MAIN DISPLAY SCREEN
CIRCUIT STATUS LINEThis line appears on all screens that relate to DS1 and DSØ testing. The line is divided with SIDE 1 information on the left and SIDE 2 information on the right. The information contained in the Status Line is a blend of MENU SELECTIONS, CIRCUIT ALARM CONDITIONS, CIRCUIT ERROR CONDITIONS and CURRENT CIRCUIT OPERATIONAL STATUS.
SIDE 2 InformationSee next two slides.
SIDE 1 InformationSee next two slides.
SLIDE 9 OF 22
BTS-1000MAIN DISPLAY SCREEN
LINE CODESelectable - AUTO, AMI, B8ZS
FRAME FORMATSelectable - SF, ESF or AUTO
SLIDE 10 OF 22
BTS-1000MAIN DISPLAY SCREEN
CIRCUIT STATUSThe letters FRM indicate that the circuit is framed and operational.All other indications such as LOS, AIS, RED, YEL are indications of a circuit that is not fully operational.
ALARM & ERROR STATUSWhen any of these DS1 circuit alarms occur (LOS, AIS, LOF, RAI) a flashing A will appear.
When any of these DS1 circuit errors occur (BPV, EXZ, FE, SLIP, B8ZS, CRC-6) a flashing E will appear.
SLIDE 11 OF 22
F6F5F4F3F2F1
DS0 DATA
RS-232 (DCE)
RCV1 RCV2
DSX-MON
TERMBRIDGED
AUX ACCESS
POWER
OFF ON
SIDE 1
SIDE 2
DS1 ACCESS
XMTRCV
VF ACCESS
XMT E&MRCV 1ABC
2DEF
3STP
A
GHI4
JKL5
MNO6
ST2PB
PRS7
TUV8
WXY9
ST3PC
KP * 0
ST# D
CANCEL ENTER
HELP NEXT PREV HOME
VOLUME
BTS1000 (BERD DAWG) Interface
RS232C (DCE)This port is set up as a DCE Modem connector, which enables the Digital Option Package to connect directly to a DTE device such as a computer, printer or remote control terminal.
DDS PORTThis 9 PIN connector is used to connect various DDS test sets and other protocol analyzers. This is an input (TTL) and output port.
SLIDE 12 OF 22
F6F5F4F3F2F1
DS0 DATA
RS-232 (DCE)RCV1 RCV2
DSX-MON
TERMBRIDGED
AUX ACCESS
POWER
OFF ON
SIDE 1
SIDE 2
DS1 ACCESS
XMTRCV
VF ACCESS
XMT E&MRCV 1ABC
2DEF
3STP
A
GHI4
JKL5
MNO6
ST2PB
PRS7
TUV8
WXY9
ST3PC
KP * 0
ST# D
CANCEL ENTER
HELP NEXT PREV HOME
VOLUME
BTS1000 (BERD DAWG) Interface
OPTION CONTROL (KEY PAD)The 4 x 4 key pad is used to enter dial digits, select stored tests, select or cancel choices from a CONFIGuration screen, and other functions being developed.
SLIDE 13 OF 22
F6F5F4F3F2F1
DS0 DATA
RS-232 (DCE)RCV1 RCV2
DSX-MON
TERMBRIDGED
AUX ACCESS
POWER
OFF ON
SIDE 1
SIDE 2
DS1 ACCESS
XMTRCV
VF ACCESS
XMT E&MRCV 1ABC
2DEF
3STP
A
GHI4
JKL5
MNO6
ST2PB
PRS7
TUV8
WXY9
ST3PC
KP * 0
ST# D
CANCEL ENTER
HELP NEXT PREV HOME
VOLUME
BTS1000 (BERD DAWG) Interface
VF ACCESS JacksThe VF ACCESS jacks are for connecting an auxiliary test set to a selected DS0 circuit for further analog or digital tests.
SLIDE 14 OF 22
F6F5F4F3F2F1
DS0 DATA
RS-232 (DCE)RCV1 RCV2
DSX-MON
TERMBRIDGED
AUX ACCESS
POWER
OFF ON
SIDE 1
SIDE 2
DS1 ACCESS
XMTRCV
VF ACCESS
XMT E&MRCV 1ABC
2DEF
3STP
A
GHI4
JKL5
MNO6
ST2PB
PRS7
TUV8
WXY9
ST3PC
KP * 0
ST# D
CANCEL ENTER
HELP NEXT PREV HOME
VOLUME
BTS1000 (BERD DAWG) Interface
DS1 SIDE 1 & SIDE 2 RCV/XMT JacksThese jacks are used to connect the test set to the circuit under test. The LEDs indicate which jacks are active.
SLIDE 15 OF 22
F6F5F4F3F2F1
DS0 DATA
RS-232 (DCE)RCV1 RCV2
DSX-MON
TERMBRIDGED
AUX ACCESS
POWER
OFF ON
SIDE 1
SIDE 2
DS1 ACCESS
XMTRCV
VF ACCESS
XMT E&MRCV 1ABC
2DEF
3STP
A
GHI4
JKL5
MNO6
ST2PB
PRS7
TUV8
WXY9
ST3PC
KP * 0
ST# D
CANCEL ENTER
HELP NEXT PREV HOME
VOLUME
BTS1000 (BERD DAWG) Interface
DS1 RCV1/RCV2 KeysThese keys are used to select the correct receiver impedance for the selected test location. The impedance selection is indicated by the two LEDs above each key.TERM is selected when the test set terminates the DS1 circuit. The TERM LEDs are lit.BRIDGE is selected if a high impedance input is required. Both LEDs are lit. The BRIDGE mode must access a terminated cable pair for readings to be accurate. This is the POWER ON default mode. MONITOR is used for resistive monitor jack applications. The MON LED will be lit.Note: If the MONITOR jack is not resistor isolated, use the BRIDGED mode.
AUXILLIARY ACCESSThis location is reserved for future options.
SLIDE 16 OF 22
F6F5F4F3F2F1
DS0 DATA
RS-232 (DCE)RCV1 RCV2
DSX-MON
TERMBRIDGED
AUX ACCESS
POWER
OFF ON
SIDE 1
SIDE 2
DS1 ACCESS
XMTRCV
VF ACCESS
XMT E&MRCV 1ABC
2DEF
3STP
A
GHI4
JKL5
MNO6
ST2PB
PRS7
TUV8
WXY9
ST3PC
KP * 0
ST# D
CANCEL ENTER
HELP NEXT PREV HOME
VOLUME
BTS1000 (BERD DAWG) Interface
FUNCTION KeysF1 - Selects STORED TESTS where available,.F2 - Selects DS1 PERFORMANCE MONITOR tests. F3 - Selects DS1 BERT tests. F4 - Selects DS0 DROP & INSERT tests. F5 - Selects the test set SYSTEM SETUP functions. F6 - Selects other test functions when available. All keys select additional functions within specific tests.
SLIDE 17 OF 22
F6F5F4F3F2F1
DS0 DATA
RS-232 (DCE)RCV1 RCV2
DSX-MON
TERMBRIDGED
AUX ACCESS
POWER
OFF ON
SIDE 1
SIDE 2
DS1 ACCESS
XMTRCV
VF ACCESS
XMT E&MRCV 1ABC
2DEF
3STP
A
GHI4
JKL5
MNO6
ST2PB
PRS7
TUV8
WXY9
ST3PC
KP * 0
ST# D
CANCEL ENTER
HELP NEXT PREV HOME
VOLUME
BTS1000 (BERD DAWG) Interface
HELP KeyThis key is used to select the built-in user’s manual. The HELP screen displayed will be directly related to the screen that was displayed before entering HELP. The NEXT and PREV keys will access all additional HELP screens related to the screen showing.Use HOME to return to the test screen.
SLIDE 18 OF 22
F6F5F4F3F2F1
DS0 DATA
RS-232 (DCE)RCV1 RCV2
DSX-MON
TERMBRIDGED
AUX ACCESS
POWER
OFF ON
SIDE 1
SIDE 2
DS1 ACCESS
XMTRCV
VF ACCESS
XMT E&MRCV 1ABC
2DEF
3STP
A
GHI4
JKL5
MNO6
ST2PB
PRS7
TUV8
WXY9
ST3PC
KP * 0
ST# D
CANCEL ENTER
HELP NEXT PREV HOME
VOLUME
BTS1000 (BERD DAWG) Interface
NEXT KeyThis key is used to move to the next screen in the set up, help or test process.
SLIDE 19 OF 22
F6F5F4F3F2F1
DS0 DATA
RS-232 (DCE)RCV1 RCV2
DSX-MON
TERMBRIDGED
AUX ACCESS
POWER
OFF ON
SIDE 1
SIDE 2
DS1 ACCESS
XMTRCV
VF ACCESS
XMT E&MRCV 1ABC
2DEF
3STP
A
GHI4
JKL5
MNO6
ST2PB
PRS7
TUV8
WXY9
ST3PC
KP * 0
ST# D
CANCEL ENTER
HELP NEXT PREV HOME
VOLUME
BTS1000 (BERD DAWG) Interface
PREV KeyThis key is used to move to the previous screen viewed in the set up,help or test process.
SLIDE 20 OF 22
F6F5F4F3F2F1
DS0 DATA
RS-232 (DCE)RCV1 RCV2
DSX-MON
TERMBRIDGED
AUX ACCESS
POWER
OFF ON
SIDE 1
SIDE 2
DS1 ACCESS
XMTRCV
VF ACCESS
XMT E&MRCV 1ABC
2DEF
3STP
A
GHI4
JKL5
MNO6
ST2PB
PRS7
TUV8
WXY9
ST3PC
KP * 0
ST# D
CANCEL ENTER
HELP NEXT PREV HOME
VOLUME
BTS1000 (BERD DAWG) Interface
HOME KeyThis key is used to escape from any screen to the Main Menu, or return from a HELP or CONFIGuration screen to the screen that was previously chosen.
SLIDE 21 OF 22
CONGRATULATIONS !!!CONGRATULATIONS !!!
You made it through this document.You made it through this document.
That’s a good thing!!That’s a good thing!!
Now refer to your manual to set up Now refer to your manual to set up
and run a test.and run a test.
We appreciate you support and your business.
If you have any questions please contact us at 402-498-8400 or
email - [email protected].
SLIDE 22 OF 22