Vertical Multi-Stage In-Line Pumps
ConstructionVertical multi-stage pumps with suction and delivery connectionsof the same diameter and arranged along the same axis (in-line).Corrosion-resistant bearing sleeves lubricated by the pumped liquid.Removal of the mechanical seal without dismantling the motor(for MXV 50, MXV 100 with motors exceeding 4 KW).A pump with thrust bearing and sleeve coupling for use of anystandard motor with IM V1 construction.
Version with frequency converter (on request)
ApplicationsFor water supply systems.For clean non-explosive liquids, without solid, filamentary orabrasive matter (with adaptation of sealing materials on request).A universal pump for civil and industrial use, for pressure-boostingsystems, fire-extinguishing systems, high-pressure washingplants, irrigation, agricultural uses and sport installations.
Operating conditionsTemperature of liquid: from -15 °C to +110 °C (up to +120 °Cfor MXV 50).Operating environment temperature: up to 40 °C.Maximum permissible pressure in pump casing: 25 bar. (16 bar for pumps with oval flanges).
MotorStandard-type: 2-pole induction motor, 50 Hz (n ≈ 2900 rpm).Construction IM V1 (EN 60034-7).Motor suitable for operation with frequency converter.Classification scheme IE3 for three-phase motors.Insulation class F.Protection IP 55.three-phase with rated voltage: up to 3 kW 230/400 V;
from 4 kW 400/690 V.
MXV 25, 32, 40, 50 MXV 65, 80, 100
Component Material
FlangeExternal jacketSuction casingDelivery casing Stainless SteelStage casing 1.4301 EN 10088 (AISI 304)ImpellerLower coverUpper coverSpacer sleevePump shaft Stainless Steel 1.4305 EN 10088 (AISI 303)Plug (for MXV 50 AISI 304)Bearing sleeve Corrosion-resistant, cemented carbideBearing in stage casing Ceramic aluminaMechanical sealISO 3069 - KU Hard metal/Carbon/EPDM.
Wear ring PPS (PTFE for MXV 40)O-rings NBR (EPDM for MXV 50)
Pump with threaded ports (G) (for MXV 25, 32, 40).Pump with flanged ports (F).Pump with oval flange ports (O) (for MXV 50).Pump without motor.Pump with standard motor.
Variants (to be specified when ordering)
With counter-flanges in chrome-nickel steel.O-rings FPM. Other mechanical seal.Pump with motor of Client's choice (if available).Single-phase motor 230 V, up to 2.2 kW.Other voltage ratings. Frequency 60 Hz.
Other variants (on request)
Materials (wetted parts)
All parts that come into contact with the liquid, including wet-endcovers, are in chrome-nickel stainless steel AISI 304.
Internal parts in contact with the liquid in chrome-nickel stainless steel,AISI 304 with pump casing and upper cover in cast iron.
Direction of rotation: clockwise as seen from the motor.
Component Material
Pump casing Cast iron GJL 250 EN 1561Upper cover
External jacketStage casing Stainless Steel 1.4301 EN 10088 (AISI 304)ImpellerSpacer sleevePump shaft Stainless Steel (AISI 303)(AISI 431 for MXV 100)Plug Stainless Steel (AISI 303)(AISI 304 for MXV 100)Bearing sleeve Corrosion-resistant, cemented carbideBearing in stage casing Ceramic alumina
(Corrosion-resistant, cemented carbide for MXV 100)Mechanical sealISO 3069 - KU
Hard metal/Carbon/EPDM
Wear ring PTFEO-rings NBR (EPDM for MXV 100)
Materials (wetted parts)
Pump without motor.Pump with standard motor.
Variants (to be specified when ordering)
O-rings FPM. Other mechanical seal.Pump with motor of Client's choice (if available).Other voltage ratings. Frequency 60 Hz. Pump with support feet for horizontal installation (H1 or H2).Support feet for horizontal installation, set. Welding counter-flanges, PN 25 (steel).
Other variants (on request)
The electropumps MXV series comply with the European Regulation no. 547/2012.
Direction of rotation: anticlockwise as seen from the motor.(clockwise as seen from the motor for MXV 100)
MXV
MXV EI Vertical Multi-Stage In-Line Pumps
Pumps with frequency converter
The MXV EI pumps are available with power from 0,75 kW up to 22 kW,the pumps are equipped with I-MAT installed on board which allows torealize a variable-speed system extremely compact and efficient, ideal inapplications of water supply and in the distribution of hot and cold water. The pump is equipped with transducers suitable for operation and isalready programmed at the factory.
Advantages- Energy saving- Compact design- Easy to use- Programmable to suit the system requirements- Reliability
CostructionThe system comprises of:- Pump- Induction motor- I-MAT Frequency converter- Motor adapter for the motor mounting of the frequency converter- Connection cable between frequency converter and induction motor- Transducers
Main featuresRated motor power output from 0,75 kW to 22 kWControl range from 1750 to 2900 rpm (2-pole) Protection against dry runningProtection against operations with closed connection portsProtection against system leakagesProtection against overcurrent in the motorProtection agains overvoltage and undervoltage of the power supplyProtection against current unbalances between phases
Mode at a constant pressurewith pressure sensor
In this mode, the system maintains the preset pressure when the flow required bythe installation changes.
Proportional pressure mode with pressure sensor
In this mode the system changes the working pressure according to the requiredflow rate.
Constant flow mode with flow meter
In this mode the system maintains a constant flow rate value in a point of theinstallation according to the required pressure.
Fixed speed mode with setting of the speed preferential rotation.
In this mode, by changing the working frequency, you may choose any operationalcurve included within the working range.
Constant temperature modewith temperature transducerIn this mode the system keeps the temperature constant inside a system bychanging the speed of the pump.
Operating modesH
Q
H
Q
H
Q
H
max
min
+-
+-
+ -
+-
MXV
3.93.013
4.93.213/1
4.93.213/2 4.93.213/3 4.93.213/4
Pipe connection
Pump with threaded ports:pipes screwed into the ports
Pump with threaded ports:pipes with union couplings(locally available)
Pump with flanged ports:pipes with counter-flanges
Installations
Vertical installation(Standard).
Horizontal installation. Variant H1: suction on the left, delivery on the right.
Variant H2: suction on the right, delivery on the left.
4567810
25-20425-20525-20625-20725-20825-210
25-212
25-214
25-21625-218
25-220
40-81740-819
32-412
32-414
32-41632-418
40-811
40-813
40-815
32-40432-40532-40632-40732-40832-410
40-80440-80540-80640-80740-80840-810
111111
2222222
333
11121314151618
171920
MXV
12345678
65-320865-320965-3210
65-3212
65-320265-320365-320465-320565-320665-3207
50-150150-150250-150350-150450-150550-150650-150750-1508
50-150950-151050-151150-151250-1513
50-151450-151550-151650-1517
50-200150-200250-200350-200450-200550-200650-200750-2008
50-200950-201050-201150-201250-2013
50-201450-201550-201650-2017
80-480680-480780-4808
80-480180-480280-480380-480480-4805
11111111
22222222
3333
678910111213
14151617
MXVNumber of stages
Pump size Stage casings with
bearingNumber of stages
Pump size Stage casings with
bearing
Variable parts Variable parts
MXV 25, 32, 40, 50 MXV 65, 80, 100
Vertical Multi-Stage In-Line Pumps
DesignationMXV L EI 25-205 G *
SeriesAISI 316L vesionWith frequency converter I-MATDN ports in mmRated capacity in m3/h (n ≈ 2900 rpm)Number of stages
Construction variantsspecial seal code (no code = standard seal)
threaded ports Gflanged ports Foval flange ports Owith motor (or without motor)* with no further designation = with standard motor
DesignationMXV L EI 65-3205 H1 *
SeriesAISI 316L vesionWith frequency converter I-MATDN ports in mmRated capacity in m3/h (n ≈ 2900 rpm)Number of stages
Construction variantsspecial seal code (no code = standard seal)
with support feet for horizontal installation H, variant 1with motor (or without motor)* with no further designation = with standard motor
Coverage chart
MXV Vertical Multi-Stage In-Line Pumps
2 4 8 3216 481 3 5 6 7 9 10 20 40 70600
50
100
150
200
250
0m /h
l/min 30 40 50 100 1000150 200
80 90100 150
1500 2000300 400 500
3
72.936/1
5 10 20 304
m
50 10040 200 300 500400Imp. g.p.m.
ft
Q
H
25-2 32-4 40-8
50-15
65-32
80-48
100-65
100-90
H
100
200
300
400
500
700
800MXVn≈ 2900 1/min
50-20
Characteristic curves and performance n ≈ 2900 rpm
H
Q
4
5
6
7
8
10
12
14
16
18
MXV 25-220
Q
η
η
3 72.983
3
kW
MXV 25-207/D
MXV 25-204/C
MXV 25-210/D
MXV 25-208/D
MXV 25-212/DMXV 25-214/DMXV 25-216/CMXV 25-218/CMXV 25-220/C
MXV 25-205/CMXV 25-206/D
HP
0,750,751,11,11,5
1,52,22,23
11
1,51,52
233444
33
445668
79,591114136159182205228
42,553
63,57485106127149170191213
44
4,74,77,47,49,29,211,411,411,4
2,32,32,72,74,34,35,35,36,66,66,6
4050
60,570,580,5101121141161181202
37,54756
65,57594112131150169188
34,543
51,5606986
103121138155173
3139
46,554,56278
93,5109124140156
2734
40,547,55468
81,595108122136
22,52834
39,545,55768
79,591102114
1721253034425159687685
Hm
m /h3
l/min
1
16,6
1,5
25
2,5
41,6
3
50
3,5
58,3
4
66,6
4,5
75
2
33,3
0
0A*A*Q
0 50
0
0.1
0.2
240
0
0
0 50
2
4
0
10
20
40
60
80
100
120
140
180
200
220
1 2 3 4
1 2 3 4
0
100
200
300
400
500
600
700
5 10 15 20U.S. g.p.m.
ft
m
20 40 60 8030 50 70m /hl/min
m /h
30
50
40
Pst
ft
NPSH
m
kW
Pst
%
230 V 400 V
Vertical Multi-Stage In-Line PumpsMXV 25-2
Test results with clean cold water, without gascontent.A safety margin of + 0.5 m is recommended forthe NPSH value.Tolerances in accordance with UNI EN ISO 9906:2012
Head and power values valid for liquids withdensity ρ = 1,0 kg/dm3 and kinematic viscosity ν= max 20 mm2/sec.
Pst = Power with reference to one stage.A* Calpeda motor currents
Pump typeMotor power
H
Q
45678
10
12
14
16
MXV 32-418
Q
3
72.9843
ηη
kW
0
MXV 32-407/D
MXV 32-404/D
MXV 32-410/D
MXV 32-408/D
MXV 32-412/CMXV 32-414/CMXV 32-416/DMXV 32-418/D
MXV 32-405/DMXV 32-406/D
HP
1,51,5223
344
5,55,5
1,11,11,51,52,2
2,23344
Hm
m /h3
l/min
41,551,562
72,583
104124145166187
2,5
41,6
405060
70,580,5101121141161181
3
50
36,546
55,5657493111130148167
4
66,6
34,543,552,561,57088105123140158
4,5
75
32,541
49,5586683
99,5116132149
5
83,3
27,534,5424956708498112126
6
100
2227,533,539
44,5566778
89,5100
7
116,6
14,518,522,526,53038
45,553
60,568
8
133,3
38,548586878
97,5117136156175
3,5
58,30Q
0 90
0.05
0.25
240
0
0
0 90
2
4
0
10
20
40
60
80
100
120
140
180
200
220
0
100
200
300
400
500
600
700
ft
m
2 3 4 5 6 7 850 100 150
35
45
55
10 20 30
2 3 4 5 6 7 8
0.1
0.2
Imp. g.p.m.
m /hl/min
ft
PstkW
Pst
m /h
NPSH
m
%
4,74,77,47,49,29,211,411,4
2,72,74,34,35,35,36,66,69,69,6
A*A*
230 V 400 V
455668
79,591114136159182205
MXV 32-4
Characteristic curves and performance n ≈ 2900 rpm
Vertical Multi-Stage In-Line Pumps
Test results with clean cold water, without gascontent.A safety margin of + 0.5 m is recommended forthe NPSH value.Tolerances in accordance with UNI EN ISO 9906:2012
Head and power values valid for liquids withdensity ρ = 1,0 kg/dm3 and kinematic viscosityν = max 20 mm2/sec.
Pst = Power with reference to one stage.A* Calpeda motor currents
Pump typeMotor power
H
Q
Q
4
5
6
7
8
10
11
13
15
17
MXV 40-819
3
3 72.392
η η
kW
MXV 40-807/C
MXV 40-804/D
MXV 40-810/D
MXV 40-808/C
MXV 40-811/DMXV 40-813/CMXV 40-815/CMXV 40-817/CMXV 40-819/C
MXV 40-805/DMXV 40-806/D
HP
23344
5,55,57,57,510
1,52,22,233
44
5,55,57,5
7,5 10
Hm
m /h3
l/min
43475971
8395
119131155179202
226
54657687
109119141163184
5
83,3
4253637485
106116138159180
6
100
4050596979
99109129149168
8
133,3
3747566675
94103122141159
9
150
3443516069
8694111128145
10
166,6
3038455360
758398113128
11
183,3
2632394551
64718496
109
12
200
2126313642
5257687889
13
216,6
4151627282
103113134154175195201206 188 178 162 143 122 99
7
116,6
0
0Q
0 140
0
0.2
0.4
240
0
0
00
2
4
0
10
20
40
60
80
100
120
140
180
200
220
0
100
200
300
400
500
600
700
ft
m
50
70
60
ft
2 4 6 8 10 12
10 20 30 40 50Imp. g.p.m.
50 100 150 200
142 4 6 8 10 12
m /hl/min
m /h
Pst
m
NPSH
%
Pst
kW
7,49,29,211,411,4
4,35,35,36,66,69,69,610,910,914,314,3
A*A*
230 V 400 V
MXV 40-8
Characteristic curves and performance n ≈ 2900 rpm
Vertical Multi-Stage In-Line Pumps
Test results with clean cold water, without gascontent.A safety margin of + 0.5 m is recommended forthe NPSH value.Tolerances in accordance with UNI EN ISO 9906:2012
Head and power values valid for liquids withdensity ρ = 1,0 kg/dm3 and kinematic viscosityν = max 20 mm2/sec.
Pst = Power with reference to one stage.A* Calpeda motor currents
Pump typeMotor power
Characteristic curves and performance n ≈ 2900 rpm
Vertical Multi-Stage In-Line Pumps
H
Q
Q0 24
0
0.6
1.0
280
0
0
20
40
60
80
100
120
140
180
200
220
4 8 200
100
200
300
400
500
600
700
25 50 75Imp. g.p.m.
ft
m
100 200 300 400150 250 350m /h
40
80
60
Pst
kW%
0.2
240800
0 4 8
12
12
16
16 20m /h0
4
NPSH
m
8
10
0
ft
20
0
0
0 25 50 75Imp. g.p.m.
m /hl/min
24
260
900
MXV 50-1501MXV 50-1502MXV 50-1503MXV 50-1504MXV 50-1505MXV 50-1506MXV 50-1507MXV 50-1508MXV 50-1509MXV 50-1510MXV 50-1511MXV 50-1512MXV 50-1513MXV 50-1514MXV 50-1515MXV 50-1516MXV 50-1517
1,11,52,234
5,55,57,57,57,59,29,21111111515
1,5234
5,57,57,5101010
12,512,51515152020
9,519,831,543,054,063,073,58697105116132143154165174185
8,417,828,639,549,557,567,0788895105121131141151159169
7,015,425,135,044,050,559,069778391107116125134140149
5,512,721,030,037,542,549,5586569769198
106113119126
10,321,433,946,057,568,079,592104114125141153165177186198
12,024,638,652,065,078,091,5105118130143159173186199211224
14,027,943,658,072,585,099,0115129141155173188202217230245
11,623,837,350,563,075,588,0101114126138155167180193204217
11,022,735,848,560,572,084,097110121133149161173186196209
3,69,516,324,030,033,539,0455154597278849094100
2,74,35,36,69,610,910,914,314,314,318,518,521,521,521,527,327,3
4,77,49,211,4
HPkW
Hm
m /h3
l/min
8
133,3
10
166,6
14
233
16
266
18
300
20
333
22
366
24
400
12
200
0
0Q
3
3 72.937
ηη
kWA*A*
230 V 400 V
1110
9
8
7
6
5
4
3
2
1
1213
14
15
16
MXV 50-1517
Pst
MXV 50-15
Test results with clean cold water, without gascontent.A safety margin of + 0.5 m is recommended forthe NPSH value.Tolerances in accordance with UNI EN ISO 9906:2012
Head and power values valid for liquids withdensity ρ = 1,0 kg/dm3 and kinematic viscosityν = max 20 mm2/sec.
Pst = Power with reference to one stage.A* Calpeda motor currents
Pump typeMotor power
H
Q
Q0 28
0
0.6
1.0
280
0
0
20
40
60
80
100
120
140
180
200
220
4 8 200
100
200
300
400
500
600
700
25 50 75Imp. g.p.m.
ft
m
100 200 300150 250 350m /h
40
80
60
Pst
kW
Pst
%
0.2
240800
0 4 8
12
12
16
16 20m /h0
4
NPSH
m
8
10
0
ft
20
0
0
0 25 50 75Imp. g.p.m.
m /hl/min
28
24
24
260
900
80
400 450
MXV 50-2001MXV 50-2002MXV 50-2003MXV 50-2004MXV 50-2005MXV 50-2006MXV 50-2007MXV 50-2008MXV 50-2009MXV 50-2010MXV 50-2011MXV 50-2012MXV 50-2013MXV 50-2014MXV 50-2015MXV 50-2016MXV 50-2017
1,12,234
5,57,57,59,29,2111115151515
18,518,5
1,534
5,57,51010
12,512,51515202020202525
10,723,335,448,561,073,085,097114127140151164177189205217
9,821,732,945,557,068,580,091108120132143154166178193205
8,719,830,042,052,562,573,083
100111122132143154165179190
7,317,526,537,546,555,564,5748999109118128138148161172
11,524,537,551,064,076,589,5102120133146158171185198214227
13,027,041,456,070,084,098,0112130144159172186201215232246
15,530,746,562,578,092,0
107,0122142158173188204219235251267
12,626,340,454,568,082,095,5109127141155168182196210227241
12,125,539,153,066,079,593,0106124137151164177191205221235
5,814,722,532,040,047,055,063778694
103111120128140149
4,011,718,026,032,537,544,050637178849199
106116124
2,75,36,69,610,914,314,318,518,521,521,527,327,327,327,33434
4,79,211,4
HPkW
Hm
m /h3
l/min
10
166,6
14
233
16
266
18
300
20
333
22
366
24
400
26
433
28
466
12
200
0
0Q
3
3 72.937
ηη
kWA*A*
230 V 400 V
11
10
9
8
7
6
5
4
3
2
1
12
13
14
15
16
MXV 50-2017
MXV 50-20
Characteristic curves and performance n ≈ 2900 rpm
Vertical Multi-Stage In-Line Pumps
Test results with clean cold water, without gascontent.A safety margin of + 0.5 m is recommended forthe NPSH value.Tolerances in accordance with UNI EN ISO 9906:2012
Head and power values valid for liquids withdensity ρ = 1,0 kg/dm3 and kinematic viscosityν = max 20 mm2/sec.
Pst = Power with reference to one stage.A* Calpeda motor currents
Pump typeMotor power
2943,558,57387102116130145174
2740,554,56882
95,5109122136163
24,53750
62,575
87,5100112125150
2233,545
56,567,57990101112135
3046617792
107123138154185
34516986103121138155172207
3755,575
93,5112131150168187225
3249
65,582
98,5115131148164197
3147,563,579,595,5111127143159191
1725,53544
52,561,57079
87,5105
MXV 65-3207/D
MXV 65-3204/C
MXV 65-3202/DMXV 65-3203/C
MXV 65-3209/E
MXV 65-3208/D
MXV 65-3210/EMXV 65-3212/D
MXV 65-3205/DMXV 65-3206/D
HPkW
45,57,51111
1515
18,518,5
5,57,5101515
202025253022
Hm
m /h3
l/min
15
250
21
350
27
450
30
500
33
550
36
600
39
650
44
733
24
400
0
0Q
72.9743
3
H
Q
MXV 65-3212
10
9
8
7
6
5
4
3
2
Q
0 500
1
2
240
0
0
20
40
60
80
100
120
140
180
200
220
10 20 30 400
100
200
300
400
500
600
700
50 100 150Imp. g.p.m.
ft
m
200 400 600 800300 500 700m /hl/min
40
80
60
η Pst
kW
Pst
%
η
0
10
0 5010 20 30 40m /h0
4
NPSHft
m
0
20
8
9,610,914,321,521,527,327,3343441
A*A*
230 V 400 V
MXV 65-32
Characteristic curves and performance n ≈ 2900 rpm
Vertical Multi-Stage In-Line Pumps
Test results with clean cold water, without gascontent.A safety margin of + 0.5 m is recommended forthe NPSH value.Tolerances in accordance with UNI EN ISO 9906:2012
Head and power values valid for liquids withdensity ρ = 1,0 kg/dm3 and kinematic viscosityν = max 20 mm2/sec.
Pst = Power with reference to one stage.A* Calpeda motor currents
Pump typeMotor power
MXV 80-48
72.1035
ft
m
m /hl/min
ft
Pst
kWPst
m /h
NPSH
m
H
Q
Q
3
3
η%η
MXV 80-4801/DMXV 80-4802/CMXV 80-4803/CMXV 80-4804/DMXV 80-4805/DMXV 80-4806/DMXV 80-4807/EMXV 80-4808/D
HPkW
45,57,5111515
18,522
5,57,5101520202530
1326,54055
68,58296
109
1224,537
51,564,577,590
103
10,722344860728496
9,520314455667788
1529,544607590105120
1836547290
108126144
2040,56181
101121142162
1734,5516986103120137
1632,548658197113129
Hm
m /h3
l/min
21
350
27
450
33
550
45
750
48
800
51
850
54
900
715,524,5354453
61,570,5
60
1000
39
650
0
0Q
4
0
2
3
1
70
80
50
7
6
5
4
3
2
1000900
200
50
6010 30
10 30
160
ft
50
60
104
6
040200
1
60
40
MXV 80-4808
700500300 800600400200
Imp. g.p.m. 15010050
600
500
400
300
200
100
04020
180
200
140
120
100
80
60
40
20
0
0
2
0
0
9,610,914,321,527,327,33441
A*A*
230 V 400 V
Characteristic curves and performance n ≈ 2900 rpm
Vertical Multi-Stage In-Line Pumps
Test results with clean cold water, without gascontent.A safety margin of + 0.5 m is recommended forthe NPSH value.Tolerances in accordance with UNI EN ISO 9906:2012
Head and power values valid for liquids withdensity ρ = 1,0 kg/dm3 and kinematic viscosityν = max 20 mm2/sec.
Pst = Power with reference to one stage.A* Calpeda motor currents
Pump typeMotor power
MXV 100-65
0
0
2
4
6
8
4
108
12
072.9743
3
H
Q
MXV 100-65
Q
0 1000
240
0
0
20
40
60
80
100
120
140
180
200
220
20 40 60 800
100
200
300
400
500
600
700
100 200 300Imp. g.p.m.
ft
m
400 800 1200 1600600 1000 1400m /hl/min
20
100
60
40
80% η
0 10020 40 60 80m /h
ft
kW
PstPst
Pst R
NPSH
m
8-2R
7
8
7-2R
6
6-2R
5
5-2R
4
4-2R
3
3-2R
2
1
2-2R
MXV(L) 100-6501MXV(L) 100-6502-2RMXV(L) 100-6502MXV(L) 100-6503-2RMXV(L) 100-6503/AMXV(L) 100-6504-2R/AMXV(L) 100-6504MXV(L) 100-6505-2RMXV(L) 100-6505MXV(L) 100-6506-2RMXV(L) 100-6506MXV(L) 100-6507-2RMXV(L) 100-6507MXV(L) 100-6508-2RMXV(L) 100-6508
HPkW
5,57,51115
18,518,5223030303737454545
7,51015202525304040405050606060
22,53346
56,56979
92,5104116127139150163174186
2231455467
75,590,5101114123136145159168181
202541
46,561,5668390
105110125130147152167
18,522
38,542
57,560,57883
98,5102117120138141157
23,53548
59,571,583
96,5109121133145156169181193
2537,551
63,576
88,5102116129141154166180193206
2839
56,567,584,595,5113125142153170181199210227
24,536,549,5627486
100113125137150162175188200
2435,548,560,572,584
97,5110122134147158172184196
Hm
m /h3
l/min
30
500
36
600
42
700
54
900
60
1000
72
1200
78
1300
16,517,534,535,551,55270
72,588,589,5105106124125141
85
1417
45
750
0
0Q
10,914,321,527,33434415454546464777777
A*
400 V
η
Characteristic curves and performance n ≈ 2900 rpm
Vertical Multi-Stage In-Line Pumps
Test results with clean cold water, without gascontent.A safety margin of + 0.5 m is recommended forthe NPSH value.Tolerances in accordance with UNI EN ISO 9906:2012
Head and power values valid for liquids withdensity ρ = 1,0 kg/dm3 and kinematic viscosityν = max 20 mm2/sec.
Pst = Power with reference to one stage.A* Calpeda motor currents
Pump typeMotor power
MXV 100-90
72.1035
ft
m
m /hl/min
ft
Pst
Pst RPst
kW
m /h
NPSH
m
H
Q
Q
3
3
η%η
MXV(L) 100-9001-1RMXV(L) 100-9001MXV(L) 100-9002-2RMXV(L) 100-9002MXV(L) 100-9003-2R/AMXV(L) 100-9003MXV(L) 100-9004-2RMXV(L) 100-9004MXV(L) 100-9005-2RMXV(L) 100-9005MXV(L) 100-9006-2RMXV(L) 100-9006
HPkW
5,57,51115
18,522303037374545
7,51015202530404050506060
17,523,536,547,559,572
85,596,5109120134144
16,5223445566981
92,5103114127138
13,520
28,541
48,562,571,58492
104113126
1017
21,535
38,553,559727689
94,5108
1924
38,549
62,57489
99,5113123138149
2127,543
55,570,584
100112127140156169
2230,544,562
75,593,5108125139156170188
20,526425368
80,597108123134150161
2025,541
51,566,578
94,5105120130146157
Hm
m /h3
l/min
45
750
54
900
60
1000
78
1300
85
1417
96
1600
108
1800
6,513,515
28,528,54446606074
75,589,5
118
1967
72
1200
0
0Q
8
10
0
4
6
2
80
100
40
20001800
400
100
12020 60
20 60
160
ft
100
120
108
12
080400
60
20
MXV 100-90
14001000600 16001200800400
Imp. g.p.m. 300200100
600
500
400
300
200
100
08040
180
200
140
120
100
80
60
40
20
0
0
4
0
0
10,914,321,527,33441545464647777
A*
400 V
6
6-2R
5-2R
4-2R
2-2R
1-1R
5
4
3
3-2R
2
1
Characteristic curves and performance n ≈ 2900 rpm
Vertical Multi-Stage In-Line Pumps
Test results with clean cold water, without gascontent.A safety margin of + 0.5 m is recommended forthe NPSH value.Tolerances in accordance with UNI EN ISO 9906:2012
Head and power values valid for liquids withdensity ρ = 1,0 kg/dm3 and kinematic viscosityν = max 20 mm2/sec.
Pst = Power with reference to one stage.A* Calpeda motor currents
Pump typeMotor power
MXV25-232-440-8
ØN.
d
43
GDN
30,231,233,334,337,238,243,144,154,656,657,631,232,236,237,241,142,152,654,657,858,836,240,141,150,651,655,856,877,378,385,786,7
MXV (F)MXV (G)
(5) (5)
MXV 25-204/CMXV 25-205/CMXV 25-206/DMXV 25-207/DMXV 25-208/DMXV 25-210/DMXV 25-212/DMXV 25-214/DMXV 25-216/CMXV 25-218/CMXV 25-220/C
kW DN afG a h1 f AD n1 n2 m1 m2HP0,750,751,11,11,51,52,22,2333
11
1,51,52233444
M80 V1M80 V1M80 V1M80 V1M90 V1M90 V1M90 V1M90 V1M100 V1M100 V1M100 V1
2525252525252525252525
250250250250250250250250250250250
G1G1G1G1G1G1G1G1G1G1G1
215215215215215215215215215215215
7575757575757575757575
372396420444478526574622680728776
210210210210210210210210210210210
180180180180180180180180180180180
150150150150150150150150150150150
100100100100100100100100100100100
12,512,512,512,512,512,512,512,512,512,512,5
MXV 32-404/DMXV 32-405/DMXV 32-406/DMXV 32-407/DMXV 32-408/DMXV 32-410/DMXV 32-412/CMXV 32-414/CMXV 32-416/DMXV 32-418/D
1,11,11,51,52,22,23344
1,51,5223344
5,55,5
M80 V1M80 V1M90 V1M90 V1M90 V1M90 V1M100 V1M100 V1M112 V1M112 V1
32323232323232323232
250250250250250250250250250250
G 1 1/4G 1 1/4G 1 1/4G 1 1/4G 1 1/4G 1 1/4G 1 1/4G 1 1/4G 1 1/4G 1 1/4
215215215215215215215215215215
75757575757575757575
372396430454478526584632680728
210210210210210210210210210210
180180180180180180180180180180
150150150150150150150150150150
100100100100100100100100100100
12,512,512,512,512,512,512,512,512,512,5
MXV 40-804/DMXV 40-805/DMXV 40-806/DMXV 40-807/CMXV 40-808/CMXV 40-810/DMXV 40-811/DMXV 40-813/CMXV 40-815/CMXV 40-817/CMXV 40-819/C
M90 V1M90 V1M90 V1M100 V1M100 V1M112 V1M112 V1M132 V1M132 V1M132 V1M132 V1
4040404040404040404040
280280280280280280280280280280280
G 1 1/2G 1 1/2G 1 1/2G 1 1/2G 1 1/2G 1 1/2G 1 1/2G 1 1/2G 1 1/2G 1 1/2G 1 1/2
225225225225225225225225225225225
8080808080808080808080
411441471511541601631711771831891
M fM P200200200200200200200200250250250200200200200200200250250250250200200200250250250250300300300300
246246246246246246246246246246246
215215215215215215215215215215215
190190190190190190190190190190190
130130130130130130130130130130130
1414141414141414141414
ISO 228 s
MXV (G)(4)kg
1819202122232526293132192021222324272930312122232526282935363839
(5)kg(6) (6)
mm
1 1 / 4
1 1 / 2
115140
DEDN
150
85100
DK
110
6576
DG
84
141919
2532
DN
40
1
444
GISO 228
253240
DN
DG
DK
DE
G
h1
f
a
P
G
20
(25
MX
4 4
0-8)
h1
af
M
AD
DN
s
m2
m1
n2 n1
fM
DN
(3)
(2)(2)3.93.011 3.93.011/1
(1)(1)
EN 1092-1 PN 25 - 40
127,5127,5127,5127,5127,5127,5127,5127,5137,5137,5137,5127,5127,5127,5127,5127,5127,5137,5137,5137,5137,5127,5127,5127,5137,5137,5137,5137,5159,5159,5159,5159,5
255255255255255255295295311311311255255255255295295311311311311255295295311311311311339339339339
627651675699733781869917991
10391087627651685709773821895943991
1039666736766822852912942
1050111011701230
1,52,22,23344
5,55,57,57,5
23344
5,55,57,57,51010
Dimensions and weights
Vertical Multi-Stage In-Line Pumps
Pump
(1) Filling(2) Draining(3) Standard position of terminal box.
(for other positions rotate motor through 90° or 180°)
Motor threadedports
flangedports
withoutmotor
withmotor
Counterflanges in stainless steel
Flanges
(4) MXV (F) = MXV (G) + 1kg (5) With standard motor (6) Net weight
Holes
MXV 50-1550-20
MXV 50-1501MXV 50-1502MXV 50-1503MXV 50-1504MXV 50-1505MXV 50-1506MXV 50-1507MXV 50-1508MXV 50-1509MXV 50-1510MXV 50-1511MXV 50-1512MXV 50-1513MXV 50-1514MXV 50-1515MXV 50-1516MXV 50-1517MXV 50-2001MXV 50-2002MXV 50-2003MXV 50-2004MXV 50-2005MXV 50-2006MXV 50-2007MXV 50-2008MXV 50-2009MXV 50-2010MXV 50-2011MXV 50-2012MXV 50-2013MXV 50-2014MXV 50-2015MXV 50-2016MXV 50-2017
kW DN a h1 f
mm
AD m4HP1,11,52,234
5,55,57,57,57,59,29,211111115151,12,234
5,57,57,59,29,2111115151515
18,518,5
1,5234
5,57,57,5101010
12,512,515151520201,534
5,57,51010
12,512,51515202020202525
M80 V1M90 V1M90 V1M112 V1M112 V1M132 V1M132 V1M132 V1M132 V1M132 V1M160 V1M160 V1M160 V1M160 V1M160 V1M160 V1M160 V1M80 V1M90 V1M100 V1M112 V1M132 V1M132 V1M132 V1M160 V1M160 V1M160 V1M160 V1M160 V1M160 V1M160 V1M160 V1M160 V1M160 V1
50505050505050505050505050505050505050505050505050505050505050505050
300300300300300300300300300300300300300300300300300300300300300300300300300300300300300300300300300300
ao
200200200200200200200200200200
200200200200200200200200200200
90909090909090909090909090909090909090909090909090909090909090909090
438438486534582693741789837885963
101110591107115512031251438438486521645693741819867915963
101110591107115512031251
127,5127,5127,5137,5137,5159,5159,5159,5159,5159,5186186186186186186186
127,5127,5137,5137,5159,5159,5159,5186186186186186186186186206206
M
255295295311311339339339339339413413459459459484484255295311311339339339413413459459484484484484538538
fM
693733781845893
103210801128117612241376142415181566161416871735693733797832984
103210801232128013741422149515431591163917411789
P
200200200250250300300300300300350350350350350350350200200250250300300300350350350350350350350350350350
MXV (5)kg (7)
27,427,929,431,833,344,345,747,248,650,157,859,360,762,263,765,166,627,427,930,331,842,844,345,753,554,956,457,859,360,762,263,765,166,6
24,625,126,629,030,541,542,944,445,847,3
24,625,127,629,040,041,542,950,752,153,6
349349397445493541589637685733781829877925973
10211069349349397445493541589637685733781829877925973
10211069
165
DEDN
DN 50
125
DK
499
DG
1950
EN 1092-2 PN 25
(6)kg (7)
40,743,147,557,461,186,688,094,996,397,8
115,8117,3136,7138,2139,7167,1168,640,746,055,959,685,192,093,4
111,5112,9132,4133,8161,3162,7164,2165,7
--
37,940,344,754,658,383,885,292,193,595,0
37,943,253,256,882,389,290,6
129,6
N. Ø
(6)(8)
(8) (8)
(6)
4.93.210/2
h1
fM
f
M
AD
DN
DN
aao 25
250
215
196
13
130
100
130
DN 50
N. 2 FORI M 12
40
m4
200
15
170
130
Ø15
G 3/8(2)
G 3/8(3)
G 3/8(3)
G 3/8(2)
G 1/4(1)
G 1/4(1)
G 1/4(1)
G 1/4(1)
(4)
P
DN
50
G 2
34
d
DN
DG
DK
DE
Pump Motor
withoutmotor
withmotor
(1) Filling and air vent(2) Air vent suction side(3) Draining(4) Standard position of terminal box.
(for other positions rotate motor through 90° or 180°)(5) MXV (L) : + 3 kg - MXV (H) : + 3 kg(6) With standard motor(7) Net weight(8) Oval flanges MXV (O)
Flanges EN 1092-2 PN 25
Holes
Oval Counterflanges
Dimensions and weights
Vertical Multi-Stage In-Line Pumps
kW DN a h1 f
mm
AD m4HP
137,5159,5159,5186186186186206206206
137,5159,5159,5186186186206206
MXV 65-3202/D MXV 65-3203/C MXV 65-3204/C MXV 65-3205/D MXV 65-3206/D MXV 65-3207/D MXV 65-3208/D MXV 65-3209/E MXV 65-3210/E MXV 65-3212/D MXV 80-4801/D MXV 80-4802/C MXV 80-4803/C MXV 80-4804/D MXV 80-4805/D MXV 80-4806/D MXV 80-4807/E MXV 80-4808/D
45,57,511111515
18,518,5224
5,57,5111515
18,522
5,57,510151520202525305,57,5101520202530
M112 V1M132 V1M132 V1M160 V1M160 V1M160 V1M160 V1M160 V1M160 V1M180 V1M112 V1M132 V1M132 V1M160 V1M160 V1M160 V1M160 V1M180 V1
656565656565656565658080808080808080
320320320320320320320320320320320320320320320320320320
105105105105105105105105105105105105105105105105105105
407473519595641687733779825917411466527618680741802864
M
311339339459459484484538538538311339339459484484538538
fM
7188128581054110011711217129013631455
72280586610771164122513631402
P
250300300350350350350350350350250300300350350350350350
MXV (5)kg (7)
455153626466687072754551546466697274
334380426472518564610656702794338373434495557618679741
DEDN
DN 50 DN 65-80
185
DK
145 8
DG
118 1965
200 160 8132 1980
EN 1092-2 PN 25 - 40
(6)kg (7)
72,893,3
100,7138140168170
--
204
72,893,3
101,7140168171
-203
N. Ø
G 1/8(2)
G 3/8(3)
(6) (6)
G 3/8(1)
G 3/8(3)
AD
(4) M
f
P
35
220
260
220
260
14
fM
DN
DKDG
DE
DN
DKDG
DE
DNDN
h1
a4.93.210/2
220
260
Ø14200
15
43
m4
G 3/8 (3)
G 3/8 (1) (2) (4)
4.93.210/3
MXV 65-3280-48
Dimensions and weights
Vertical Multi-Stage In-Line Pumps
Pump
(1) Filling and air vent(2) Air vent suction side(3) Draining
Motorwithoutmotor
withmotor
Flanges
(4) Standard position of terminal box. (for other positions rotate motor through 90° or 180°) (5) MXV (L) : + 3 kg (6) With standard motor (7) Net weightMXV (H) : + 3 kg
Holes
Dimensions and weights
MXV 100-65100-90
MXV 100-6501MXV 100-6502-2RMXV 100-6502MXV 100-6503-2RMXV 100-6503/AMXV 100-6504-2R/AMXV 100-6504MXV 100-6505-2RMXV 100-6505MXV 100-6506-2RMXV 100-6506MXV 100-6507-2RMXV 100-6507MXV 100-6508-2RMXV 100-6508MXV 100-9001-1RMXV 100-9001MXV 100-9002-2RMXV 100-9002MXV 100-9003-2R/AMXV 100-9003MXV 100-9004-2RMXV 100-9004MXV 100-9005-2RMXV 100-9005MXV 100-9006-2RMXV 100-9006
kW f m2m1n2n1 M
mm
fmPN
5,57,51115
18,518,52230303037374545455,57,51115
18,522303037374545
HP
7,510152025253040404050506060607,51015202530404050506060
161616161616161616162525252525161616161616161616162525
M132 V1M132 V1M160 V1M160 V1M160 V1M160 V1M180 V1M200 V1M200 V1M200 V1M200 V1M200 V1M225 V1M225 V1M225 V1M132 V1M132 V1M160 V1M160 V1M160 V1M180 V1M200 V1M200 V1M200 V1M200 V1M225 V1M225 V1
190190190190190190190190190190190190190190190199199199199199199199199199199199199
240240240240240240240240240240240240240240240260260260260260260260260260260260260
265265265265265265265265265265265265265265265280280280280280280280280280280280280
316316316316316316316316316316316316316316316341341341341341341341341341341341341
7378298499419411033103311311131122312231315131514071407737737849849941941103810381131113112231223
a
365365365365365365365365365365365365365365365380380380380380380380380380380380380
339339459484538538538611611611611611708708708339339459484538538611611611611708708
107611681308142514791571157117421742183418341926202321152115107610761308133314791479164916491742174219311931
AD
159,5159,5186186206206206315315315315315338338338
159,5159,5186186206206315315315315338338
P
300300350350350350350400400400400400450450450300300350350350350400400400400450450
8185,588,59393
97,598
105,5105,5110110
114,5117,512212282,582,589899393
100100104104
110,5110,5
123,3127,8164,5195
--
227330,5330,5335360
364,5432,5437437
124,8124,8165191
-222325325354354
425,5425,5
SizeMXVkg (5)
(4)kg (5)
DN
DK
DE
(4)
230
DEDN
255
180
DK
190
8
8
16
PN
25
19
23
100
100
EN 1092-2
n2
m2
m1
n1
N. 4 x Ø15
DN DN
AD
M
fM
140
a
45
f
P
(1)(1)
(2)
(3)
N. Ø
Pump Motorwithoutmotor
withmotor
(3) Standard position of terminal box. (for other positions rotate motor through 90° or 180°) (4) With standard motor (5) Net weight
Flanges
Holes
Vertical Multi-Stage In-Line Pumps
(1) Filling and air vent(2) Draining
ØN.
d
43
GDN
36,637,639,740,743,844,850,651,662,164,165,137,638,642,843,848,649,660,162,165,866,842,847,648,658,659,663,864,885,386,3100,5101,5
MXV EI (F)MXV EI (G)
MXV EI 25-204/CMXV EI 25-205/CMXV EI 25-206/DMXV EI 25-207/DMXV EI 25-208/DMXV EI 25-210/DMXV EI 25-212/DMXV EI 25-214/DMXV EI 25-216/CMXV EI 25-218/CMXV EI 25-220/C
kW DN afG a h1 f AD n1 n2 m1 m2HP0,750,751,11,11,51,52,22,2333
11
1,51,52233444
M80 V1M80 V1M80 V1M80 V1M90 V1M90 V1M90 V1M90 V1M100 V1M100 V1M100 V1
2525252525252525252525
250250250250250250250250250250250
G1G1G1G1G1G1G1G1G1G1G1
215215215215215215215215215215215
7575757575757575757575
372396420444478526574622680728776
210210210210210210210210210210210
180180180180180180180180180180180
150150150150150150150150150150150
100100100100100100100100100100100
12,512,512,512,512,512,512,512,512,512,512,5
MXV EI 32-404/DMXV EI 32-405/DMXV EI 32-406/DMXV EI 32-407/DMXV EI 32-408/DMXV EI 32-410/DMXV EI 32-412/CMXV EI 32-414/CMXV EI 32-416/DMXV EI 32-418/D
1,11,11,51,52,22,23344
1,51,5223344
5,55,5
M80 V1M80 V1M90 V1M90 V1M90 V1M90 V1M100 V1M100 V1M112 V1M112 V1
32323232323232323232
250250250250250250250250250250
G 1 1/4G 1 1/4G 1 1/4G 1 1/4G 1 1/4G 1 1/4G 1 1/4G 1 1/4G 1 1/4G 1 1/4
215215215215215215215215215215
75757575757575757575
372396430454478526584632680728
210210210210210210210210210210
180180180180180180180180180180
150150150150150150150150150150
100100100100100100100100100100
12,512,512,512,512,512,512,512,512,512,5
MXV EI 40-804/DMXV EI 40-805/DMXV EI 40-806/DMXV EI 40-807/CMXV EI 40-808/CMXV EI 40-810/DMXV EI 40-811/DMXV EI 40-813/CMXV EI 40-815/CMXV EI 40-817/CMXV EI 40-819/C
M90 V1M90 V1M90 V1M100 V1M100 V1M112 V1M112 V1M132 V1M132 V1M132 V1M132 V1
4040404040404040404040
280280280280280280280280280280280
G 1 1/2G 1 1/2G 1 1/2G 1 1/2G 1 1/2G 1 1/2G 1 1/2G 1 1/2G 1 1/2G 1 1/2G 1 1/2
225225225225225225225225225225225
8080808080808080808080
411441471511541601631711771831891
M fM P200200200200200200200200250250250200200200200200200250250250250200200200250250250250300300300300
246246246246246246246246246246246
215215215215215215215215215215215
190190190190190190190190190190190
130130130130130130130130130130130
1414141414141414141414
ISO 228 s
MXV EI (G)(4)
kg (5)
mm
1 1 / 4
1 1 / 2
115140
DEDN
150
85100
DK
110
6576
DG
84
141919
2532
DN
40
1
444
GISO 228
253240
DN
DG
DK
DE
G
h1
f
a
P
G
20
(25
MX
V E
I 40
-8)
h1
af
M
AD
DN
s
m2
m1
n2 n1
AS
AG
fM
DN
(3)
(2)(2)3.93.011 3.93.011/1
(6)(1)
EN 1092-1 PN 25 - 40
286286286286286286286286294294294286286286286286286294294294294286286286294294294294321321368368
AS105105105105105105118118118118118105105105105118118118118118118105118118118118118118118118153153
AG190190190190190190210210210210210190190190190210210210210210210190210210210210210210210210281281
255255255255255255295295311311311255255255255295295311311311311255295295311311311311339339339339
6276516756997337818699179911039108762765168570977382189594399110396667367668228529129421050111011701230
1,52,22,23344
5,55,57,57,5
23344
5,55,57,57,51010
MXV EI25-232-440-8
Dimensions and weights
Vertical Multi-Stage In-Line Pumps
Pump
(1) Filling(2) Draining(3) Standard position of I-MAT
(for other positions rotate motor through 90° or 180°)(4) MXV EI (F) = MXV EI (G) + 1kg (5) Net weight(6) Pressure transducer
Motor threadedports
flangedports
Counterflanges in stainless steel
Holes
Flanges in accordanceEN 1092-2 PN 25 - 40
MXV EI 50-1550-20
MXV EI 50-1501MXV EI 50-1502MXV EI 50-1503MXV EI 50-1504MXV EI 50-1505MXV EI 50-1506MXV EI 50-1507MXV EI 50-1508MXV EI 50-1509MXV EI 50-1510MXV EI 50-1511MXV EI 50-1512MXV EI 50-1513MXV EI 50-1514MXV EI 50-1515MXV EI 50-1516MXV EI 50-1517MXV EI 50-2001MXV EI 50-2002MXV EI 50-2003MXV EI 50-2004MXV EI 50-2005MXV EI 50-2006MXV EI 50-2007MXV EI 50-2008MXV EI 50-2009MXV EI 50-2010MXV EI 50-2011MXV EI 50-2012MXV EI 50-2013MXV EI 50-2014MXV EI 50-2015MXV EI 50-2016MXV EI 50-2017
kW DN a h1 f
mm
AD m4HP1,11,52,234
5,55,57,57,57,59,29,211111115151,12,234
5,57,57,59,29,2111115151515
18,518,5
1,5234
5,57,57,5101010
12,512,515151520201,534
5,57,51010
12,512,51515202020202525
M80 V1M90 V1M90 V1
M112 V1M112 V1M132 V1M132 V1M132 V1M132 V1M132 V1M160 V1M160 V1M160 V1M160 V1M160 V1M160 V1M160 V1M80 V1M90 V1
M100 V1M112 V1M132 V1M132 V1M132 V1M160 V1M160 V1M160 V1M160 V1M160 V1M160 V1M160 V1M160 V1M160 V1M160 V1
50505050505050505050505050505050505050505050505050505050505050505050
300300300300300300300300300300300300300300300300300300300300300300300300300300300300300300300300300300
ao
200200200200200200200200200200
200200200200200200200200200200
90909090909090909090909090909090909090909090909090909090909090909090
438438486534582693741789837885963
101110591107115512031251438438486521645693741819867915963
101110591107115512031251
286286286294294321321368368368393393393393393471471286286294294321368368393393393393471471471471491491
M
255295295311311339339339339339413413459459459484484255295311311339339339413413459459484484484484538538
AG
190190210210210210210281281281281281281281281350350190210210210210281281281281281281350350350350350350
AS
105105118118118118118153153153153153153153153190190105118118118118153153153153153153190190190190190190
fM
693733781845893
103210801128117612241376142415181566161416871735693733797832984
103210801232128013741422149515431591163917411789
P
200200200250250300300300300300350350350350350350350200200250250300300300350350350350350350350350350350
349349397445493541589637685733781829877925973
10211069349349397445493541589637685733781829877925973
10211069
165
DEDN
DN 50
125
DK
499
DG
1950
EN 1092-2 PN 25
(5)kg (6)
47,149,754,564,969,194,696,0
109,7111,1112,6130,6132,1151,5153,0154,5202,1203,647,153,063,467,693,1
106,8108,2126,3127,7147,2148,6196,3197,7199,2200,7207,1208,6
44,346,951,762,166,391,893,2
106,9108,3109,8
44,350,260,764,890,3
104,0105,4
144,4
N. Ø
(8)
(8)
4.93.210/2
f
130
h1
fM
M
DN
DN
aao 25
250
215
196
13
130
100DN 50
N. 2 FORI M 12
40
m4
200
15
170
130
Ø15
G 3/8(2)
G 3/8(2)
G 3/8(3)
G 1/4(1)
G 1/4(1)
P
DN
50
G 2
34
AD
(7)(4)
AS
AG
(4)
d
DN
DG
DK
DE
(1) Filling and air vent(2) Air vent suction side(3) Draining(5) MXV EI (L) : + 3 kg
MXV EI (H) : + 3 kg(6) Net weight(7) Pressure transducer(8) Oval flanges MXV (O)
(4) Standard position of I-MAT. (for other positions rotate motor through 90° or 180°)
Pump Motor
Flanges EN 1092-2 PN 25
Holes
OvalCounterflanges
Dimensions and weights
Vertical Multi-Stage In-Line Pumps
MXV EI Vertical Multi-Stage In-Line Pumps
MXV EI
(5)kg (6)
DEDN
DN 50 DN 65-80
185
DK
145 8
DG
118 1965
200 160 8132 1980
EN 1092-2 PN 25 - 40
N. Ø
MXV EI 65-3202/DMXV EI 65-3203/CMXV EI 65-3204/CMXV EI 65-3205/DMXV EI 65-3206/DMXV EI 65-3207/DMXV EI 65-3208/DMXV EI 65-3209/EMXV EI 65-3210/EMXV EI 65-3212/DMXV EI 80-4801/DMXV EI 80-4802/CMXV EI 80-4803/CMXV EI 80-4804/DMXV EI 80-4805/DMXV EI 80-4806/DMXV EI 80-4807/EMXV EI 80-4808/D
kW DN a h1 f
mm
AD m4HP4
5,57,511111515
18,518,5224
5,57,5111515
18,522
5,57,510151520202525305,57,5101520202530
M112 V1M132 V1M132 V1M160 V1M160 V1M160 V1M160 V1M160 V1M160 V1M180 V1M112 V1M132 V1M132 V1M160 V1M160 V1M160 V1M160 V1M180 V1
656565656565656565658080808080808080
320320320320320320320320320320320320320320320320320320
105105105105105105105105105105105105105105105105105105
407473519595641687733779825917411466527618680741802864
294321368393393471471491491491294321368393471471491491
M
311339339459459484484538538538311339339459484484538538
AG
210210281281281350350350350350210210281281350350350350
AS
118118153153153190190190190190118118153153190190190190
fM
718812858
1054110011711217129013631455722805866
10771164122513401402
P
250300300350350350350350350350250300300350350350350350
334380426472518564610656702794338373434495557618679741
80,8101,3115,5152,8154,8203205
--
23980,8
101,3116,5154,8203206
-238
DN
DKDG
DE
DN
DKDG
DE
G 1/8(2)
G 3/8(3)
G 3/8(1)
G 3/8(3)
AD
M
f
P
35
220
260
220
260
14
fM
DNDN
h1
a4.93.210/2
220
260
Ø14200
15
43
m4
G 3/8 (3)
G 3/8 (1) (2)
(4)
(7)
(4)
AS
AG
65-3280-48
Dimensions and weights
PumpMotor
Holes
Flanges in accordanceEN 1092-2 PN 25 - 40
(1) Filling and air vent(2) Air vent suction side(3) Draining(4) Standard position of I-MAT
(for other positions rotate motor through 90° or 180°)(5) MXV (L) : + 3 kg, MXV (H) : + 3 kg(6) Net weight (7) Pressure transducer
kW f m2m1n2n1 M
mm
fmPNHP a AD AG ASPSize
MXV EI
kg (4)
DN
DK
DE
AS
AG
230
DEDN
225
180
DK
190
8
8
16
PN
25
19
23
100
100
EN 1092-2
n2
m2
m1
n1
N. 4 x Ø15
DN DN
AD
M
fM
140
a
45
f
P
(5)(1)(1)
(2)
(3)
MXV EI 100-6501MXV EI 100-6502-2RMXV EI 100-6502MXV EI 100-6503-2RMXV EI 100-6503/AMXV EI 100-6504-2R/AMXV EI 100-6504MXV EI 100-9001-1RMXV EI 100-9001MXV EI 100-9002-2RMXV EI 100-9002MXV EI 100-9003-2R/AMXV EI 100-9003
7,51015202525307,51015202530
5,57,51115
18,518,5225,57,51115
18,522
16161616161616161616161616
M132 V1M132 V1M160 V1M160 V1M160 V1M160 V1M180 V1M132 V1M132 V1M160 V1M160 V1M160 V1M180 V1
190190190190190190190199199199199199199
240240240240240240240260260260260260260
265265265265265265265280280280280280280
316316316316316316316341341341341341341
737829849941941
10331033737737849849941941
365365365365365365365380380380380380380
1076116813081425147915711571107610761308133314791479
339339459484538538538339339459484538538
210281281350350350350210281281350350350
3213683934714914-1491321368393471491491
118153153190190190190118153153190190190
300300350350350350350300300350350350350
131,3142,6179,3230
--
262132,8139,6179,8226
-257
N. Ø
Flanges in accordanceEN 1092-2
MXV EI Vertical Multi-Stage In-Line Pumps100-65100-90
Dimensions and weights
Pump Motor
Holes
(1) Filling and air vent(2) Draining(3) Standard position of I-MAT
(for other positions rotate motor through 90° or 180°)(4) Net weight(5) Pressure transducer
Features
Vertical Multi-Stage In-Line PumpsMXV
3.93.112
MXV 25, 32, 40, 50
MXV 65, 80
3.93.029
Long Service Life with Standard MotorPump with thrust bearing without additional axial loads on the motor bearings.Any standard motor V1 design (suitable to be lifted in vertical position) can beused, of our choice or of Client’s choice.
Easy Assembly of the MotorWith the single-piece sleeve coupling the pump unit can be supplied fullyassembled also without the motor. This eliminates the risk of damage causedby shifting of the pump shaft during transportation.The motor is simply inserted in the coupling and fastened to the flange with-out the necessity for adapting the axial position of the pump shaft.
Removable mechanical SealEasy removal of the mechanical sealwithout dismantling the motor (for MXV50-15, MXV 50-20 and MXV 100 withmotors exceeding 4 KW).
Extra SafetySingle-piece coupling guard to be removed only by means of a tool, positionedaround the lantern bracket, thus avoiding accidental pushing and rubbingagainst the coupling.
Low Cost InstallationVertical construction with reduced pump height for installation in smallspaces. In-line connections to simplify the piping layout with the possibility of insertingthe pump in straight pipe-lines. Disassembly, inspection or cleaning of internal parts without removal of piping.
Robust and ReliableSingle PN 25 construction for all pump sizes.The suction and discharge nozzles arranged in-line absorb the forces of the pip-ing on the pump without the creation of distorting loads causing local friction andearly wears.The lantern brackets compact and robust design maintains a sure alignmentbetween rotating and fixed parts, reducing vibration.The upper cover design prevents entrapment of air around the mechanical seal.
Low-Noise OperationThe water filled shroud around the stages and thick external walls, worktogether for low-noise operation.Low-noise standard motor.
MXV 50-15, MXV 50-20
Vertical Multi-Stage In-Line Pumps
ConstructionVertical multi-stage pumps with suction and delivery connections ofthe same diameter and arranged along the same axis (in-line).Corrosion-resistant bearing sleeves lubricated by the pumped liquid.Removal of the mechanical seal without dismantling the motor(for MXVL 50, MXVL 100 with motors exceeding 4 KW).A pump with thrust bearing and sleeve coupling for use of anystandard motor with IM V1 construction.
Version with frequency converter (on request)
ApplicationsFor water supply systems.For clean non-explosive liquids, without solid, filamentary orabrasive matter (with adaptation of sealing materials on request).A universal pump for civil and industrial use, for pressure-boostingsystems, fire-extinguishing systems, high-pressure washingplants, irrigation, agricultural uses and sport installations.
Operating conditionsTemperature of liquid: from -15 °C to +110 °C (up to +120 °Cfor MXVL 50).Operating environment temperature: up to 40 °C.Maximum permissible pressure in pump casing: 25 bar. (16 bar for pumps with oval flanges).
MotorStandard-type: 2-pole induction motor, 50 Hz (n ≈ 2900 rpm).Construction IM V1 (EN 60034-7).Motor suitable for operation with frequency converter.Classification scheme IE3 for three-phase motors.Insulation class F.Protection IP 55.three-phase with rated voltage: up to 3 kW 230/400 V;
from 4 kW 400/690 V.
MXVL 25, 32, 40, 50 MXVL 65, 80, 100
Pump with threaded ports (G) (for MXVL 25, 32, 40). Pump with flanged ports (F).Pump with oval flange ports (O) (for MXVL 50).Pump without motor.Pump with standard motor.
Variants (to be specified when ordering)
With counter-flanges in chrome-nickel steel.O-rings FPM. Other mechanical seal.Pump with motor of Client's choice (if available).Single-phase motor 230 V, up to 2.2 kW.Other voltage ratings. Frequency 60 Hz.
Other variants (on request)
Direction of rotation: clockwise as seen from the motor.Direction of rotation: anticlockwise as seen from the motor.(clockwise as seen from the motor for MXVL 100)
Pump without motor.Pump with standard motor.
Variants (to be specified when ordering)
O-rings FPM. Other mechanical seal.Pump with motor of Client's choice (if available).Other voltage ratings. Frequency 60 Hz. Pump with support feet for horizontal installation (H1 or H2).Support feet for horizontal installation, set. Welding counter-flanges, PN 25 (steel).
Other variants (on request)
Component Material
FlangeExternal jacketSuction casingDelivery casing Stainless SteelStage casing 1.4404 EN 10088 (AISI 316L)ImpellerLower coverUpper coverSpacer sleevePump shaft Stainless SteelPlug 1.4404 EN 10088 (AISI 316L)Bearing sleeve Corrosion-resistant, cemented carbideBearing in stage casing Ceramic aluminaMechanical sealISO 3069 - KU Hard metal/Carbon/EPDM.
Wear ring PPS (PTFE for MXVL 40)O-rings NBR (EPDM for MXVL 50)
Materials (wetted parts)
All parts that come into contact with the liquid, including wet-endcovers, are in chrome-nickel-molybdenum stainless steel AISI 316L.
Internal parts in contact with the liquid with pump casing and uppercover in chrome-nickel-molybdenum stainless steel AISI 316L.
Component Material
Pump casing Stainless SteelUpper cover 1.4404 EN 10088 (AISI 316L)
External jacketStage casing Stainless SteelImpeller 1.4404 EN 10088 (AISI 316L)Spacer sleevePump shaft Stainless Steel (AISI 316L)(AISI 329 for MXVL 100)Plug Stainless Steel 1.4404 EN 10088 (AISI 316L)Bearing sleeve Corrosion-resistant, cemented carbideBearing in stage casing Ceramic alumina
(Corrosion-resistant, cemented carbide for MXVL 100)Mechanical sealISO 3069 - KU
Hard metal/Carbon/EPDM
Wear ring PTFEO-rings NBR (EPDM for MXV 100)
Materials (wetted parts)
The electropumps MXVL series comply with the European Regulation no. 547/2012.
MXVL AISI 316L
2 4 8 3216 481 3 5 6 7 9 10 20 40 70600
50
100
150
200
250
0m /h
l/min 30 40 50 100 1000150 200
80 90100 150
1500 2000300 400 500
3
72.936/1
5 10 20 304
m
50 10040 200 300 500400Imp. g.p.m.
ft
Q
H
25-2 32-4 40-8
50-15
65-32
80-48
100-65
100-90
H
100
200
300
400
500
700
800MXVn≈ 2900 1/min
50-20
Coverage chart
For characteristic curves, dimensions and weights see MXV
Vertical Multi-Stage In-Line PumpsMXVL AISI 316L