solar heating with cooling (senior capstone project)

Post on 04-Jul-2015

765 Views

Category:

Documents

2 Downloads

Preview:

Click to see full reader

DESCRIPTION

Presentation on the results of our built solar heating and cooling system for our house. Presentation highlight testing methods and results.

TRANSCRIPT

Solar Heating with Cooling

Elliott Layus

Ben Ly

Lily Duncan

Problem: Testing the residential heating and

cooling system our team designed.

anti-scald valve

radiator

winter

winter

summer

summer

summer

cooling tower

storage tank propelene

glycol tank

collector

DHW

radiator

Testing: Setup and Procedure

Solar Panel Test Setup

• Test Performed using the primary tank storage (50 gallon tank)

Heat Exchanger Test

• Test Performed using the Storage Tank

Cooling Test Setup Test Performed using the Secondary storage tank (250

gallon tank)

Testing Equipment

• Thermocouples

• Data Logger

Piping

Thermal Wells

Other Testing

Flow-Tests

• Domestic Hot Water Hose

• Solar Panels

• Cooling Tower

Test Results

Results: Solar Response

Domestic Hot Water

Heat Rate:

Cost of Natural Gas: $.995/Therm

Cost Savings of Test: .04869

Gallons Used in Test: 22.5

Domestic Hot Water

• Savings per gallon .00322

• Weekly Estimated Usage

– Showers =472.5

– Laundry =160

– Dishes =20

– Sink =75

727.5

Weekly Savings $2.34/Week $121.70/yr

Delivers: 100 MJ/day

Costs: 14.08 MJ/day

COP: 7.10

Solar Space Heating

Total Gains from Useful Heat

October November December January Febuary March April

(Mega Joules)/day 134 130 41 43 106 103 118

Actual(Mega

Joules)/day 150 133 100 100 133 150 180

Savings ($/day) 1.80 1.60 1.20 1.20 1.60 1.80 2.30

Average

1.70

Total$306/year

Cooling Tower

• A tank response test was performed for 1 hour

• The tank was cooled by 2.5 K (275 gal.)

• 11.12 Mj of energy was rejected

• A standard efficiency A/C unit would provide

2.85 MJ

• Actual savings depends on conditions of surrounding and usage pattern

Cooling cycle: Storage Tank Response

284

286

288

290

292

294

296

298

300

0 0.5 1 1.5 2 2.5 3 3.5 4 4.5

Tem

pe

ratu

re (

C)

time (hours)

Cooling cycle for week of July 27, evening

Tank temperature

wetbulb temp

Cost BreakdownSavings per Year:

$4287 year payback

Cooling Tower Fabrication

Resin $135.00

Glass $60.00

Sheet Metal $30.00

Vents $10.00

Pipe Fittings $20.00

Paint $44.00

Pads $24.00

Screws and Fasteners $30.00

Roofing Material $14.00

Fan $22.00

Power Inverter $50.00

Redwood $25.00

Fiberglass Tools $20.00

Fiberglass Prep Materials $35.00

$519.00

Solar Panels and Mounting

Solar Panel Package- 2pumps

8 3x7 Solar Panels $900.00

Mounting Hardware $348.00

$1,248.00

System Configuration

2 Tanks $150.00

Pipes and Fittings $720.00

Fans $44.00

Heat Exchangers $116.00

Pumps $162.00

$1,192.00

Total $2,959.00