GROUND
100 AT
USE 2 - 22 mm square THHN wire
TO THE NEAREST POWER SOURCE
215 AT 15 AT
4
1
3
M
65
L.O. L.O.
SPARESPARE
L.O. L.O.
L.O. L.O.
L.O.
C.O.
87
109
1211C.O.
REF.
RANGE
C.O.
15 AT 15 AT
15 AT 15 AT
15 AT 15 AT
15 AT 30 AT
15 AT 15 AT
BRANDS.PURPOSE OF INDICATING THE DESIRED QUALITY BUT NOT TO LIMIT THE USE OF OTHER
BRAND NAMES MENTIONED IN THE PLANS AND SPECIFICATIONS ARE ONLY FOR THE
BLACK, BLUE AND RED. FOR GROUND WIRE GREEN OR WHITE.
DEMS TO BE USED.
APPLICATION.
APPROVAL PRIOR TO THE INSTALLATION.
B.) CONVENIENCE OUTLET ........... 0.30 M. ABOVE FLR. FIN. OR AS REQUIRED
A.) LIGHTING SWITCHES ............... 1.40 M. ABOVE FLOOR FINISH
THE MOUNTING HEIGHT OF WIRING DEVICES SHALL BE AS FOLLOWS :
BALLAST. LAMP SHALL BE COOL WHITE THROUGHOUT SPECIFIED AREA OF
D.) KILOWATTHOUR METER .......... MIN. OF 1.2 M., MAX. OF 1.8 M. ABOVE FLOOR LINE. ALL
C.) PANEL BOARDS & CABINETS... 1.60 M. ABOVE FLR. FIN. @ CENTER OR AS REQUIRED
OTHERWISE INDICATED. THE MINIMUM SIZE FOR POWER CABLE SHALL BE 3.5 SQ. MM.
WIRES SHOULD BE COLOR CODED. RECOMMENDED COLOR FOR POWER FEEDERS ARE
ALL WIRES SHALL BE COPPER AND THERMOPLASTIC INSULATED TYPE " THWN " UNLESS
BY THE BUREAU OF PRODUCT STANDARDS (BPS) OF THE DEPARTMENT OF TRADE AND
ONLY BRAND NEW DEVICES, EQUIPMENT MATERIALS AND SUPPLIES (DEMS) APPROVED
THE PROVISIONS OF THE LATEST EDITION OF THE PHILIPPINE ELECTRICAL CODE, THE
ALL ELECTRICAL INSTALLATION WORKS HEREIN SHALL BE DONE IN ACCORDANCE WITH
MOUNTING HEIGHTS SHALL BE SUBJECTED TO THE ARCHITECT'S / ENGINEER'S
ALL FLUORESCENT FIXTURES SHALL HAVE HIGH POWER FACTOR AND PRE - HEAT
REQUIRED, THE SUPPLIER SHOULD FURNISH PROOFS REGARDING THE QUALITY OF
RECOGNIZED TESTING ORGANIZATION SHALL BE USED IN THE PROJECT WHEN
INDUSTRY (DTI) OR FOREIGN MADE PRODUCTS APPROVED BY INTERNATIONALLY
SUPERVISION OF A DULY LICENSED ELECTRICAL ENGINEER / MASTER ELECTRICIAN.
REGULATIONS OF ENFORCING LOCAL GOVERNMENT, AND UNDER THE IMMEDIATE
FIRE CODE OF THE PHILIPPINES, THE NATIONAL BUILDING CODE, THE RULES AND
GENERAL SPECIFICATIONS
PRESENTED BY:
EVSU_CAAD_BSAR 4A STUDENT
SUBJECT: PROJECT TITLE:
LOCATION:
CHECKED BY:
DATE CHECKED:
SHEET CONTENTS: SHEET NO.
ELECTRICAL
SCALE
MANAGBANAG, EMMANUEL II L.MAGALLANES, EDRALYN COMP
413TWO - STOREY RESIDENTIAL BLDG. ARCH. HERVY G. CATILOGO, UAP
INSTRUCTOR
E36 20
RISER DIAGRAM NOT DRAWN TO SCALE
TWO - STOREY RESIDENTIAL BLDG.
E20 24
RISER DIAGRAM N.D.T.S.
GENERAL SPECIFICATION N.D.T.S.