Customer: Continuity Demo Date: August 20, 2012 Confidential 1
Private Cloud Health Check Report
A total of 15 potential downtime and data loss risks were detected by AvailabilityGuard/Cloud health check assessment of your private cloud environment.
Issues are assigned a priority according to the following criteria:
Priority 1: risk of extended downtime or data loss to a mission-critical business service Priority 2: risk of extended downtime or data loss in any production system Priority 3: risk of performance degradation in a production system Priority 4: any risk to non-production system Priority 5: deviation from best practices
HIGH PRIORITY THREATS
Trading Email OnlineBanking
HR AllServices
CRM
3 3
2
1 1 1
Priority 1-3 Issues by Business Service
HA Setting SAN DataProtection
VIManageme
ntPriority 1 2 4Priority 2 2 1 1Priority 3 1
High Priority Issues by Area
AvailabilityGuard/Cloud Health Check Report
Customer: Continuity Demo Date: August 20, 2012 Confidential 2
FINDING SUMMARY
Affected Business Services
Area Category Possible Impact Priority # of Open
Tickets
Tickets
Online Banking
HA Setting
Cluster configuration errors
• Extended downtime (single point of failure in a system designed for High Availability)
• Potential data loss upon fail-over
1 2 498, 40
Trading SAN
SAN I/O configuration issues
• Single Point of Failure • Risk of data corruption
1 3 62, 28, 230
CRM SAN
Unauthorized storage access
• Risk of massive data corruption affecting multiple Virtual Machines
1 1 31
All Services
VI Mgmt VI best practices
• Inability to manage the VI 2 1 43
Email, DWH
SAN
Incorrect storage array configuration
• Reduced performance • Reduced service availability 2 2 46,
173
Email Data Protection
Cluster storage access
• No compliance with data retention requirement
• Insufficient performance and redundancy expected after fail-over
2 1 185
HR HA Setting
VI best practices
• Reduced performance • Inefficient utilization of I/O
resources 3 1 92
Document Mgmt
Optimization
Optimization • Sub-optimal performance • Opportunity to eliminate storage
hot-spots and bottlenecks 5 4
42, 211, 118, 36
AvailabilityGuard/Cloud Health Check Report
Customer: Continuity Demo Date: August 20, 2012 Confidential 3
TICKET 498
Gap ID 00451DTSMIS Name Datastore not configured on all ESX cluster nodes
Severity INFO Status OPEN
Categories Downtime, Extended Recovery Time Rating Detected on Nov 22, 2011 1:56:37 AM
Verified on Dec 28, 2011 1:53:10 AM
SUMMARY
The datastore MAFS-PRD02 of ESX cluster ma_prd_01 at site Boston is not configured on all cluster nodes.
DESCRIPTION
The datastore MAFS-PRD02 of ESX cluster ma_prd_01 is not configured on all cluster nodes. This might result in prolonged downtime of dependent virtual machines (see impact).
The following table lists the datastores inconsistently configured on the ESX cluster ma_prd_01:
Datastore db01 db03 db02 db03 db02
MAFS-PRD10 Configured Configured Configured Configured Configured
MAFS-PRD11 Configured Configured Configured Configured Configured
MAFS-PRD02 Configured Configured Configured Not configured
Configured
MAFS-PRD07 Configured Configured Configured Configured Configured
IMPACT
Virtual machines fail-over to an alternate cluster node is possible only if that node has access to all datastores the virtual machines rely on. Since some of the cluster nodes have only partial access to datastore MAFS-PRD02, the dependent virtual machines might suffer an extended downtime upon cluster node outage.
RESOLUTION
Make sure that the underlying datastore storage volumes are mapped to all ESX nodes. Rescan storage on the cluster nodes that do not use the specified datastore.
AvailabilityGuard/Cloud Health Check Report
Customer: Continuity Demo Date: August 20, 2012 Confidential 4
TICKET 40
Gap ID 00462VMTCV Name ESX servers of different CPU architecture sharing a datastore
Severity WARNING Status OPEN
Categories Downtime Rating Detected on Jan 23, 2012 12:11:39 PM
Verified on Jan 30, 2012 12:48:59 AM
SUMMARY
ESX cluster DELL g6 at site Tokyo has nodes with different CPU vendor.
DESCRIPTION
VMware HA is feature of an ESX cluster designed to provide transparent virtual machine fail-over in the event of a physical node outage. Hardware configuration does not need to be identical across all cluster nodes, and some nodes may have less CPUs and memory than others. However, it is a best practice that all nodes in the same cluster will have the same CPU architecture and vendor, to prevent unexpected system crash upon virtual machine failover or VMotion (see impact).
The following table lists the ESX servers of different CPU architectures:
ESX host CPU type
TKesx19 Intel(R) Xeon(R) CPU E5335 @ 2.00GHz
TKesx21 Intel(R) Xeon(R) CPU E5430 @ 2.66GHz
TKesx24 Dual-Core AMD Opteron(tm) Processor 2218
IMPACT
Attempting to perform live migration (VMotion) of a virtual machine between two physical servers of different CPU architectures will fail, running the risk of unplanned outage of the virtual machine.
RESOLUTION
Make sure that the all cluster nodes have the same CPU architecture.
AvailabilityGuard/Cloud Health Check Report
Customer: Continuity Demo Date: August 20, 2012 Confidential 5
TICKET 62
Gap ID 00245DeadPath Name Devices with dead paths
Severity WARNING Status OPEN
Categories Availability Rating Detected on Jan 27, 2012 12:25:03 PM
Verified on Jan 30, 2012 12:46:14 AM
SUMMARY
ESX cluster node TKvc02 of ESX cluster O2 at site Tokyo has dead SAN I/O paths.
DESCRIPTION
ESX cluster node TKvc02 of ESX cluster O2 at site Tokyo is using SAN storage volumes. Some of the SAN I/O paths to these storage volumes are unavailable. This might result in reduced performance and redundancy.
The following table shows the unavailable paths:
Local file system
PV Dead path SAN device Unavailable paths/Total # of
paths
Lun1 HITACHI Fibre Channel Disk (naa.FF0000)
fc.df09b:3c-fc.ffffffffffffffff:f2-naa.FF0000 4472 /0000 1/2
Lun2 HITACHI Fibre Channel Disk (naa.FF0001)
fc.df09b:3c-fc.ffffffffffffffff:f2-naa.FF0001 4472 /0001 1/2
Lun3 HITACHI Fibre Channel Disk (naa.FF0003)
fc.df09b:3c-fc.ffffffffffffffff:f2-naa.FF0003 4472 /0003 1/2
IMPACT
Having only one live path to storage volumes might lead to:
• Redundancy loss, single-point-of-failure issue • Increased risk of downtime • Degraded performance
RESOLUTION
Reconfigure the lost paths using your multi-pathing software. If the issue cannot be resolved at the software level - check related hardware for possible faults. Examples for hardware configuration issues:
• Incorrect zoning or masking definitions • Switch outage • Physical link problems • Excessively long paths (e.g., with more than 6 hops) • Incorrect mapping definitions at the storage array • Etc.
AvailabilityGuard/Cloud Health Check Report
Customer: Continuity Demo Date: August 20, 2012 Confidential 6
TICKET 31
Gap ID 00478VMDSUAC Name Unauthorized SAN access to VMware datastore
Severity ERROR Status OPEN
Categories Tampering Rating Detected on Sep 19, 2011 2:30:14 AM
Verified on Sep 27, 2011 2:49:31 AM
SUMMARY
VMware datastore VD12 defined in datacenter London is accessed through the SAN by unauthorized hosts.
DESCRIPTION
VMware datastore VD12 defined in datacenter London at site London is using Symmetrix device which is accessed by ESX hosts that are not members of the same datacenter. This might lead to data corruption (see impact).
The following table presents the Symmetrix device and the unauthorized hosts:
Symmetrix device Host Device
4127 /102E ESX host ld-esx1 EMC Fibre Channel Disk (naa.fe4344)
4127 /102E ESX host ld-esx2 EMC Fibre Channel Disk (naa.fe4344)
IMPACT
Symmetrix devices allocated for datastore use should be mapped only to ESX servers that are members of the same datacenter. This can be useful to allow migration of virtual machines using VMotion. However, it is highly dangerous to allow SAN access to the underlying Symmetrix devices by any other host, especially if one is not an ESX server. This might result in unexpected data corruption and data loss that will affect any Virtual Machine using the datastore - which might also lead to downtime.
RESOLUTION
Remove the SAN mapping of the Symmetrix device to the unauthorized hosts.
AvailabilityGuard/Cloud Health Check Report
Customer: Continuity Demo Date: August 20, 2012 Confidential 7
TOPOLOGY
AvailabilityGuard/Cloud Health Check Report
Customer: Continuity Demo Date: August 20, 2012 Confidential 8
TICKET 46
Gap ID 00242PRIMARY Name Host accessing remote primary devices
Severity WARNING Status OPEN
Categories Optimization Rating Detected on Jan 23, 2012 1:11:53 PM
Verified on Jan 30, 2012 12:50:47 AM
SUMMARY
ESX cluster node VC-9b4 of ESX cluster HP-BL-680 at site Tokyo is utilizing storage volumes located at site Kofu.
DESCRIPTION
ESX cluster node VC-9b4 of ESX cluster HP-BL-680 at site Tokyo is utilizing storage volumes located at site Kofu. This might result in performance degradation and unexpected outage.
The following table identifies the storage volumes in use by ESX cluster node VC-9b4 of ESX cluster HP-BL-680 at site Tokyo:
LV/VG/FS/DB Physical volume Storage volume
Storage array site
VMFS datastore VMAX_S70 EMC Fibre Channel Disk (naa.6d37) 4001 /726 Kofu
VMFS datastore VMAX_S112 EMC Fibre Channel Disk (naa.6e46) 4001 /73B Kofu
IMPACT
The host may experience sub-optimal performance. Also, additional load on the network is generated, which potentially can be avoided and may impact the performance of other replication sessions.
Finally, unless the configuration is intentional, then any planned or unplanned outage of site London might lead to unexpected errors or failure of ESX cluster node VC-9b4 of ESX cluster HP-BL-680.
RESOLUTION
Unless configured this way by design, migrate the storage volumes used to the local site. Pay attention to using the right storage tier and performance characteristics for the new storage volumes.
Finally, remember to check if scripts, scheduled tasks and array consistency group definitions are involved in the current configuration, as these will also require adjustment if used.
Note: If the host or array is not located at the site specified in the ticket, use the Configuration Wizard to correct the current site definition by associating the host or array with the correct site.
RESOLUTION
Similar tickets were opened for additional hosts.
AvailabilityGuard/Cloud Health Check Report
Customer: Continuity Demo Date: August 20, 2012 Confidential 9
TOPOLOGY
AvailabilityGuard/Cloud Health Check Report
Customer: Continuity Demo Date: August 20, 2012 Confidential 10
TICKET 28
Gap ID 00318SANIOSHSTG Name Hosts accessing shared storage with different number of SAN I/O paths
Severity ERROR Status OPEN
Categories Availability, Performance Rating Detected on Jan 23, 2012 12:10:23 PM
Verified on Jan 30, 2012 12:47:55 AM
SUMMARY
The shared Symmetrix devices storing datastore PCB6 of datacenter LAB at site Tokyo are accessed with different number of SAN I/O paths.
DESCRIPTION
The shared Symmetrix devices storing datastore PCB6 of datacenter LAB are accessed by 2 nodes of the ESX cluster HP-BL-680. These cluster nodes are accessing these Symmetrix devices with different number of SAN I/O paths. This might result in performance degradation and increased risk of unexpected downtime (see impact).
Datastore PCB6 of datacenter LAB
Physical volume Source Symmetrix device Number of paths from VC-9b5 Number of paths from VC-9b4
EMC Fibre Channel Disk (naa.6d37) on 2 hosts
4001 /727 1 4
IMPACT
Having cluster nodes that access the same shared storage with different number of SAN I/O paths might result in performance degradation upon failover or switchover, since some cluster nodes have more paths than others. Since some of the cluster nodes are accessing the storage volumes with a single I/O path, it creates a single-point-of-failure, which might result in unexpected downtime and extended recovery time.
RESOLUTION • Determine how many paths are required for the SAN storage volumes • Add paths to the devices with inadequate configuration • Strive to ensure end-to-end path redundancy (e.g., using separate array ports, fabric switches and host HBAs)
as much as possible
AvailabilityGuard/Cloud Health Check Report
Customer: Continuity Demo Date: August 20, 2012 Confidential 11
TICKET 230
Gap ID 00490ESXPVLUNNUM Name ESX server physical volume has inconsistent LUN number
Severity ERROR Status OPEN
Categories Data Risk Rating Detected on Nov 22, 2011 1:55:32 AM
Verified on Dec 28, 2011 1:50:10 AM
SUMMARY
ESXi cluster node prd-cl477 of ESX cluster wss-cl-prd at site New York has physical volume managed by VMware MPIO which has inconsistent LUN number.
DESCRIPTION
When ESX server uses SAN devices with VMware MPIO (with multiple HBA ports), it is important that the LUN number will be consistent between the physical paths, otherwise, it might lead to data corruption (see impact).
LUN number inconsistency was detected on ESXi cluster node prd-cl477 of ESX cluster wss-cl-prd at site New York, which uses SAN devices with inconsistent LUN number.
The following table lists the physical volumes of prd-cl477 and the LUN number for each physical path:
Physical path LUN number
Datastore DMX-01 on Pseudo PV EMC Fibre Channel Disk (sym.5643) on Symmetrix device 4678 /0D4
fc.34f:1e4f-fc.559:559-sym.5643 24
fc.34f:1e4f-fc.556:556-sym.5643 23
The following VMs are affected by the gap:
• Windows VM x1 • Windows VM x2 • Windows VM x3 • Linux VM l56 • Linux VM l57 • Linux VM l58 • Linux VM l309 • Linux VM l310 • Linux VM l311 • Linux VM l503
IMPACT
When ESX server is using VMware MPIO with different HBA ports and the LUN number is inconsistent, there is a risk of data corruption. Since the ESX server is unaware that it uses the same SAN volume, it might treat it as different SAN volume and corrupt it's on data.
Resolution
AvailabilityGuard/Cloud Health Check Report
Customer: Continuity Demo Date: August 20, 2012 Confidential 12
Deactivate/Unmount the datastore/file system. Remap the LUN with the correct LUN number. Rescan for new devices. Activate the datastore.
TOPOLOGY
AvailabilityGuard/Cloud Health Check Report
Customer: Continuity Demo Date: August 20, 2012 Confidential 13
TICKET 92
Gap ID 00322SANIOSHSTG Name Hosts accessing shared storage with different SAN I/O policy
Severity WARNING Status OPEN
Categories Performance Rating Detected on Aug 04, 2011 8:22:24 AM
Verified on Sep 27, 2011 4:06:59 PM
SUMMARY
The shared HDS logical units storing TrueCopy copy of datastore RP-prd-sap3 of datacenter Milan at site Milano are accessed with different SAN I/O policy.
DESCRIPTION
The shared HDS logical units storing TrueCopy copy of datastore RP-prd-sap3 of datacenter Milan are accessed by 2 nodes of the ESX cluster PPRD. These cluster nodes are accessing these HDS logical units with different SAN I/O policy. This might result in performance degradation (see impact).
TrueCopy copy of datastore RP-prd-sap3 of datacenter Milan:
Physical volume Source HDS logical unit
Replica HDS logical unit
ravel82 I/O policy ravel80 I/O policy
HITACHI Fibre Channel Disk (naa.60db5) on 2 hosts
2306 /1238 3901 /1238 VMW_PSP_RR (2 paths) VMW_PSP_FIXED (2 paths)
Additional information to the table above: • Replication layout path: TrueCopy
IMPACT
In addition to achieving redundancy, SAN I/O path policy may also be used to achieve higher I/O capacity through load balancing. The I/O policy is usually chosen to match the usage profile of the storage volumes. Having different I/O policy between cluster nodes might result in performance degradation upon failover or switchover, since at least one of the cluster nodes is not configured with the optimal configuration.
RESOLUTION • Determine the I/O policy required for the SAN storage volumes • Configure this policy to the devices with inadequate configuration • Strive to ensure end-to-end path redundancy (e.g., using separate array ports, fabric switches and host HBAs) as
much as possible
AvailabilityGuard/Cloud Health Check Report
Customer: Continuity Demo Date: August 20, 2012 Confidential 14
TICKET 43
Gap ID 00463VCTRDRSFA Name vCenter Management Server with fully automated DRS
Severity INFO Status OPEN
Categories Best Practice Rating Detected on Aug 30, 2011 8:20:11 PM
Verified on Aug 31, 2011 7:07:39 PM
SUMMARY
The VM pd45-b-6 running vCenter Management Server is configured with fully automated DRS.
DESCRIPTION
If vCenter Management Server has been installed on a virtual machine within an ESX cluster it manages, it is recommended to disable DRS for that virtual machine, to prevent extended outage of vCenter upon certain failure scenarios (see impact).
The ESX cluster MA-CL-602 at New York is managed by vCenter installed on the virtual machine pd45-b-6. This virtual machine is configured with fully automated DRS.
IMPACT
When the virtual machine running vCenter is down, it is impossible to manage the datacenters in its scope, Therefore, it is important to be able to start this virtual machine as fast as possible. If the virtual machine running vCenter is configured with fully automated DRS, it may unexpectedly migrate between cluster nodes, without the awareness of the VMware administrator. In this case, finding the virtual machine involves connecting to each ESX host in the cluster until the vCenter Management Server is found.
RESOLUTION
Disable DRS for the virtual machine running vCenter Management Server by changing the automation level.
In addition, it is recommended to: • Document where the vCenter Server is located. • Enable HA for the virtual machine running the vCenter Server, and setting the startup priority to "high". • Make sure other services and servers on which vCenter depends are also starting automatically, with a high
priority and in the correct order (Active Directory, DNS, SQL, others...). • Make sure that the virtual machine running vCenter gets enough resources by setting the shares for both Memory
and CPU to "high".
AvailabilityGuard/Cloud Health Check Report
Customer: Continuity Demo Date: August 20, 2012 Confidential 15
TICKET 185
Gap ID 00454DSLEN Name Disallow Snapshot LUN option disabled on ESX host
Severity WARNING Status OPEN
Categories Downtime, Best Practice, Data Risk Rating Detected on May 25, 2012 4:23:45 PM
Verified on Jun 16, 2012 1:33:06 AM
SUMMARY
The LVM.DisallowSnapshotLun option is disabled on ESX cluster node PD-CL-54 of ESX cluster ST-NT-04 at site NEDC-12.
DESCRIPTION
The LVM.DisallowSnapshotLun option controls whether an ESX server is allowed to mount storage volumes as VMFS even if the disk signature do not match. This option is usually used when recovering VMFS from Point-in-Time copies.
By default this option is enabled, to prevent duplicate allocation of the same VMFS from two (or more) different disks. A gap has been detected where this option is disabled on ESX cluster node PD-CL-54 of ESX cluster ST-NT-04 at site NEDC-12. This might lead to unexpected behavior in the ESX configuration (see impact).
Virtual machines affected by this gap:
• Windows VM wmsv45 • Linux VM cig5l055 • Windows VM wmsv654 • Windows VM wmsv655 • Windows VM vt772 • Windows VM vt774 • Linux VM lndoraw2 • Linux VM lndora57 • Linux VM hj875 • Linux VM jko654 • Linux VM bdf46 • Linux VM ts4567
IMPACT
Keeping LVM.DisallowSnapshotLun disabled (set to "0") on an ESX host might result in conflicting storage access and data loss when Point-in-Time copies are created at the storage layer. Since both source and target (copy) disks LUNs have the same disk ID, ESX will map each pair to the same VMFS. An attempt to write to the target will result in data corruption of the source.
LVM.DisallowSnapshotLun is usually changed from the default enabled state ("1") during maintenance, when access to storage based Point-in-Time copies is required for recovery purposes. It is important to reset it back to the "enabled" state as soon as possible.
AvailabilityGuard/Cloud Health Check Report
Customer: Continuity Demo Date: August 20, 2012 Confidential 16
RESOLUTION
Make sure that possible maintenance work has been completed and change the value of the option LVM.DisallowSnapshotLUN back to "1".
TOPOLOGY
AvailabilityGuard/Cloud Health Check Report
Customer: Continuity Demo Date: August 20, 2012 Confidential 17
TICKET 42
Gap ID 00225DBF Name Mixture of database files
Severity INFO Status OPEN
Categories Best Practice Rating Detected on Jan 23, 2012 1:00:54 PM
Verified on Jan 30, 2012 12:40:52 AM
SUMMARY
Local file system C:\ on Windows VM rgfab at site Tokyo contains a mixture of database files.
DESCRIPTION
Having different database file sets stored on the same storage volumes may result in incomplete copy of one or more of the databases, if future use of Point-in-Time copies is planned for these databases. In addition, performance issues may arise. Furthermore, it is recommended to store each database on a separated set of storage volumes.
The following table lists the database file-sets that are stored on local file system C:\ on Windows VM rgfab:
Database File Type
Oracle database ora_v_27 on Windows VM rgfab Control files
Oracle database ora_v_27 on Windows VM rgfab Log files
Oracle database ora_v_27 on Windows VM rgfab Data files
The storage volumes that are storing the database files are not replicated.
IMPACT
If different file types are stored on the same storage volumes, they would compete over the same I/O resources, possibly resulting in suboptimal database performance. Moreover, since data files and transaction log files are the two most I/O intensive components of the database, it is a best practice to store different file types on separated storage volumes and spindles. This minimizes contention for the logs as new writes come in from the database and any old transaction log information is streamed out during incremental transaction log backups. It also isolates the sequential write and random read activity for these members from other volumes with differing access characteristics.
In addition, if both data and archived transaction log files are stored on the same storage volumes, then safe use of Point-in-Time copies is prevented, since:
• Some transaction logs will not be available for recovery • The database copy might not recover successfully, since a log switch is required after data file replication ends
and before archived transaction log replication starts. When both data files and archived transaction log files are stored on the same storage volumes, this best practice cannot be implemented. This might result in corrupt database blocks (sometime referred to as "split block") which may go unnoticed.
AvailabilityGuard/Cloud Health Check Report
Customer: Continuity Demo Date: August 20, 2012 Confidential 18
RESOLUTION
Consider separating your databases into different groups of storage volumes, thus eliminating data corruption risk and optimizing performance.
TOPOLOGY
AvailabilityGuard/Cloud Health Check Report
Customer: Continuity Demo Date: August 20, 2012 Confidential 19
TICKET 173
Gap ID 00300STRGSPLTPS Name Storage volume physical split
Severity INFO Status OPEN
Categories Performance, Best Practice, Consistency Rating Detected on May 25, 2012 4:18:58 PM
Verified on Jun 16, 2012 1:30:55 AM
SUMMARY
Storage array inconsistency was detected on Symmetrix devices storing VG ws-prd-vg on Linux VM prd-ws-ne-56 at site NEDC-12.
DESCRIPTION
VG ws-prd-vg on Linux VM prd-ws-ne-56 at site NEDC-12 is stored on Symmetrix devices of different storage arrays.
This might result in degraded performance and data corruption or loss (see impact).
The following table lists the Symmetrix devices storing VG ws-prd-vg on Linux VM prd-ws-ne-56:
VM Physical volume/Disk VMware Datastore Source Symmetrix device Storage array
Sd0 on prd-ws-ne-56 PD-B6LUN02 2757 /1707 Symmetrix 2757
Sd1 on prd-ws-ne-56 PD-B7LUN37 4325 /124B Symmetrix 4325
Sd2 on prd-ws-ne-56 PD-B7LUN40 4325 /147C Symmetrix 4325
IMPACT
Since the data is stored on several arrays, it will suffer downtime even when only one of the arrays is down.
If the data is replicated, upon split, the consistency of the replicas is not ensured for Symmetrix devices that are not a part of a consistency group (Composite group with enabled consistency mode).
Business impact:
• SAPR3
RESOLUTION
Review the mappings to the Symmetrix devices and consider remapping them on the same storage array.
Otherwise, consider using consistency group (Composite group with enabled consistency mode) on those storage volumes.
AvailabilityGuard/Cloud Health Check Report
Customer: Continuity Demo Date: August 20, 2012 Confidential 20
TOPOLOGY
AvailabilityGuard/Cloud Health Check Report
Customer: Continuity Demo Date: August 20, 2012 Confidential 21
TICKET 211
Gap ID 00397HBASO Name Suboptimal HBA configuration
Severity WARNING Status OPEN
Categories Availability, Performance Rating Detected on Nov 22, 2011 1:50:37 AM
Verified on Dec 28, 2011 1:52:10 AM
SUMMARY
I/O redundancy has a single-point-of-failure in the HBA level on ESX cluster node sdf56 of ESX cluster CLNY8 at site New York.
DESCRIPTION
To ensure end-to-end path redundancy you must use separate array ports, fabric switches and host HBAs. A gap has been detected where physical volumes of ESX cluster node sdf56 of ESX cluster CLNY8 at site New York are configured with multi-pathing, but they have a single point of failure in the HBA level.
This means that either the physical paths are mapped to a single HBA port or that multiple ports are in use, but these ports are on the same HBA device. The following section provides detailed information about these physical volumes.
The following physical volumes are storing datastore DMX-05 of datacenter New York at site New York:
Host Pseudo PV Symmetrix device HBA port
ESX cluster node sdf56 of ESX cluster CLNY8
EMC Fibre Channel Disk (sym.5674) 4457 /421 vmhba1
The following list displays the available HBAs on sdf56:
• vmhba0 • vmhba1 • vmhba2 • vmhba3
IMPACT
Having multiple paths using a single HBA device eliminates the multipathing in the host level. The data will not be available upon failure of a single HBA.
RESOLUTION
Make sure that each physical path (of each pseudo PV) uses a different HBA port device. Make sure that the HBA distribution is identical between volumes storing the same data (e.g. volume group). If necessary, install a new HBA device on the host.
AvailabilityGuard/Cloud Health Check Report
Customer: Continuity Demo Date: August 20, 2012 Confidential 22
TICKET 118
Gap ID 00260DBLFRD Name Database log files on suboptimal storage
Severity INFO Status OPEN
Categories Performance, Best Practice Rating Detected on Nov 22, 2011 1:57:37 AM
Verified on Dec 28, 2011 1:59:10 AM
SUMMARY
Symmetrix devices storing log file of 3 databases (model, msdb, master) on Windows cluster node spo-info396 of MSCS MSCLUSTER05 are stored on suboptimal storage.
DESCRIPTION
To achieve optimal performance, it is a best practice to store database log files on RAID1, RAID0+1 or RAID1+0. The RAID level of the Symmetrix devices storing the log files of 3 (model, msdb, master) on Windows cluster node spo-info396 of MSCS MSCLUSTER05 do not meet this standard. This might lead to performance degradation (see impact).
The following databases store their log files on these Symmetrix devices:
• SQL Server database sql06 /master on Windows cluster node spo-info396 of MSCS MSCLUSTER05 • SQL Server database sql06 /model on Windows cluster node spo-info396 of MSCS MSCLUSTER05 • SQL Server database sql06 /msdb on Windows cluster node spo-info396 of MSCS MSCLUSTER05
The following table lists the Symmetrix devices and their RAID levels:
Physical volume Source Symmetrix device RAID level
Disk5 on spo-info396 4678 /33F RAID5
IMPACT
Since the database log files are I/O intensive (both read and write), database vendors recommend RAID mirroring (for data protection) and striping (for performance). The recommended RAID levels are:
• RAID 1+0 • RAID 0+1 • RAID 1 (while not striped, it still offers significantly better performance than RAID5 and similar shared parity
configurations)
Using other RAID levels might significantly reduce database performance.
RESOLUTION
Allocate storage volumes with a proper RAID level that provides high performance and configure the databases to store the log files on these devices.
AvailabilityGuard/Cloud Health Check Report
Customer: Continuity Demo Date: August 20, 2012 Confidential 23
TOPOLOGY
AvailabilityGuard/Cloud Health Check Report
Customer: Continuity Demo Date: August 20, 2012 Confidential 24
TICKET 36
Gap ID 00239PSWP Name Swap device on sub-optimal storage
Severity INFO Status OPEN
Categories Performance Rating Detected on Nov 22, 2011 1:59:37 AM
Verified on Dec 28, 2011 1:55:10 AM
SUMMARY
Windows VM ipfg5 at site LA has swap files stored on RAID6 devices.
DESCRIPTION
Windows VM ipfg5 at site LA has swap files stored on Hitachi RAID6 devices. This configuration might seriously affect its performance (see impact).
The following swap files are defined on host ipfg5:
Swap File VG Size Raid Level
C:\pagefile.sys N/A 2GB RAID6
Swap file C:\pagefile.sys is stored on the following RAID6 devices:
PV Source Storage Volume Raid Level
HITACHI Fibre Channel Disk (naa.668) 2270 /0068 RAID6
IMPACT
Swap files are extremely volatile and will typically involve huge amounts of I/O. For this reason, vendors will always suggest to store them on devices which offer the best possible I/O characteristics in terms of access time, I/O operations per second and throughput.
RAID5 devices offer significantly slower write performance than other storage options, such as unprotected (RAID0) or mirrored (RAID1) configurations. This might result in dramatical performance degradation of the host.
Business impact:
• ESX LA • Exchange
RESOLUTION
Consider migrating the swap files from the current storage devices to unprotected or RAID1 devices.
AvailabilityGuard/Cloud Health Check Report
Customer: Continuity Demo Date: August 20, 2012 Confidential 25
TOPOLOGY
AvailabilityGuard/Cloud Health Check Report
Customer: Continuity Demo Date: August 20, 2012 Confidential 26
NODE COMPARISON REPORT
OPERATING SYSTEM
Component esx-nt-ew-101 esx-nt-ew-102 esx-nt-ew-103 esx-nt-ew-104
Version 4.0.0 4.1.0 4.1.0 4.1.0
Version Edition VMware ESXi 4.0.0 build-261974
VMware ESXi 4.1.0 build-433742
VMware ESXi 4.1.0 build-433742
VMware ESXi 4.1.0 build-433742
Version Level 261974 433742 433742 433742
OPERATING SYSTEM OPTIONS
Option esx-nt-ew-101 esx-nt-ew-102 esx-nt-ew-103 esx-nt-ew-104
FT.TCPNoDelayPrimary 0 1 1 1
FT.Vmknic vmk1 vmk2 vmk2 vmk2
Mem.VMXMinMB 32 56 56 56
Misc.HostAgentUpdateLevel 2 1 1 1
Misc.TimerMaxHardPeriod 2000 100000 100000 100000
Net.MaxPageInQueueLen 500 75 75 75
Net.TcpipDefLROMaxLength 16000 65535 65535 65535
Syslog.Remote.Hostname N/A nyctsyslog N/A nyctsyslog