ppt on rs logix 5000

Post on 26-May-2015

636 Views

Category:

Engineering

27 Downloads

Preview:

Click to see full reader

TRANSCRIPT

By:-ANIL MAURYA

ELECTRICAL & ELECTRONICS

ENGINEER

1

� A Programmable controller is a solid state user programmable control system with functions to control logic, sequencing, timing, arithmetic data manipulation and counting capabilities. control logic, sequencing, timing, arithmetic data manipulation and counting capabilities.

� Programming changes are easy to enter by maintenance personal and plant engineer.

� Programmable control systems can survive harsh, industrial environments.

2ANIL MAURYA

ELECTRICAL & ELECTRONICS ENGINEER

Why Choose RSLogix 5000?

� Innovations� No need to point to physical memory addresses when writing code.

Use names to represent data variables. � Use names to represent data variables.

RSLogix 5000 : No access to memory addresses

RSLogix 500 : Can access memory directly

Low-level language

3ANIL MAURYA

ELECTRICAL & ELECTRONICS ENGINEER

Advantages:

Used to program all Automation Logix platforms: � ControlLogix� ControlLogix� CompactLogix� FlexLogix� DriveLogix.

4ANIL MAURYA ELECTRICAL &

ELECTRONICS ENGINEER

�� Devicenet variable speed drivesDevicenet variable speed drives

�� Ethernet wireless controlEthernet wireless control

�� PanelView control / monitoring of equipmentPanelView control / monitoring of equipment

5ANIL MAURYA

ELECTRICAL & ELECTRONICS ENGINEER

6ANIL MAURYA

ELECTRICAL & ELECTRONICS ENGINEER

7ANIL MAURYA

ELECTRICAL & ELECTRONICS ENGINEER

� Compact I/O has a unique modular rackless design, which both contributes to system cost savings and reduces parts inventory

� Its communication bus, typically found in � Its communication bus, typically found in the I/O rack, is instead integrated into each Compact I/O module

8ANIL MAURYA

ELECTRICAL & ELECTRONICS ENGINEER

9ANIL MAURYA

ELECTRICAL & ELECTRONICS ENGINEER

� Simple and affordable processors with broad capabilities to address applications such as material handling, HVAC control, assembly operations, small process control, and SCADA applications.

� Advanced instruction-set based on PLC-5 mid-size processors.

� Each SLC 5/01 processor has a DH-485 port for � Each SLC 5/01 processor has a DH-485 port for programming and processor-to-processor communication initiated from the other node.

� SLC 5/02, SLC 5/03, SLC 5/04 and SLC 5/05 processors have communication ports that can initiate communication (e.g., Ethernet, DH+, DH-485, or RS-232-C).

10ANIL MAURYA

ELECTRICAL & ELECTRONICS ENGINEER

Customize Processors

� ControlNet

DeviceNet � DeviceNet

� Universal Remote I/O

� BASIC programming capability

11ANIL MAURYA

ELECTRICAL & ELECTRONICS ENGINEER

12ANIL MAURYA

ELECTRICAL & ELECTRONICS ENGINEER

13

ANIL MAURYA ELECTRICAL & ELECTRONICS

ENGINEER

14

ANIL MAURYA ELECTRICAL & ELECTRONICS

ENGINEER

15

ANIL MAURYA ELECTRICAL & ELECTRONICS

ENGINEER

16

ANIL MAURYA ELECTRICAL & ELECTRONICS

ENGINEER

17

ANIL MAURYA ELECTRICAL & ELECTRONICS

ENGINEER

18

ANIL MAURYA ELECTRICAL & ELECTRONICS

ENGINEER

19

ANIL MAURYA ELECTRICAL & ELECTRONICS

ENGINEER

20

ANIL MAURYA ELECTRICAL & ELECTRONICS

ENGINEER

21

ANIL MAURYA ELECTRICAL & ELECTRONICS

ENGINEER

� Modify while running

� Fine-tune an operating control systemincluding PID loops

� Reduces development time

� Troubleshooting

22

ANIL MAURYA ELECTRICAL & ELECTRONICS

ENGINEER

23

ANIL MAURYA ELECTRICAL & ELECTRONICS

ENGINEER

24

ANIL MAURYA ELECTRICAL & ELECTRONICS

ENGINEER

� DF1 protocol is a data-link layer protocol that combines features of subcategories D1 and F1 of ANSI x3.28 specification.

Half-duplex protocol (master-slave communication)� Half-duplex protocol (master-slave communication)

� Full-duplex protocol (peer-to-peer communication)

� Formal Driver Type: Serial, Client or Server

� Connection type: RS-232 or RS-48525

ANIL MAURYA ELECTRICAL & ELECTRONICS ENGINEER

26

ANIL MAURYA ELECTRICAL & ELECTRONICS

ENGINEER

PLC Replacement Programming Cable for the RSlogix PLC Replacement Programming Cable for the RSlogix Series Series

�� Allen Bradley:Allen Bradley: 17611761--CBLCBL--PM02PM02

CableCable

�� Supports RSLinx communications (DF1 or DHSupports RSLinx communications (DF1 or DH--485) 485) between SLC 5000, controllogix, and 1761 devices: between SLC 5000, controllogix, and 1761 devices:

�� For example:For example:

��NET DNINET DNI

��NET AICNET AIC

��NET ENI NET ENI 27

ANIL MAURYA ELECTRICAL & ELECTRONICS

ENGINEER

28

ANIL MAURYA ELECTRICAL & ELECTRONICS

ENGINEER

� Mixing Media on a DeviceNet trunk line

� Thick, Thin, and Flat (KwikLink) are 120 ohm impedance cables

� Apply the 'weakest link' theory when calculating distances allowed.

� when mixing cables, use KwikLink specs. To determine � when mixing cables, use KwikLink specs. To determine maximum length allowed

� Return (V-) and shield should be grounded in accordance with DNet requirements; (reference DN-6.7.2) available on Rockwell website

� Proper grounding discussed in Knowledgebase record G21030.

29

ANIL MAURYA ELECTRICAL & ELECTRONICS

ENGINEER

EthernetEthernet 1761 NET ENI1761 NET ENI ControlLogixControlLogix⇒⇒⇒⇒⇒⇒⇒⇒ ⇒⇒⇒⇒⇒⇒⇒⇒

ControlLogixControlLogix 1761 NET DNI1761 NET DNI CompactLogixCompactLogix⇒⇒⇒⇒⇒⇒⇒⇒ ⇒⇒⇒⇒⇒⇒⇒⇒

CompactLogixCompactLogix 1761 NET AIC 1761 NET AIC PLC 5000PLC 5000⇒⇒⇒⇒⇒⇒⇒⇒ ⇒⇒⇒⇒⇒⇒⇒⇒

30

ANIL MAURYA ELECTRICAL & ELECTRONICS

ENGINEER

InternetInternet DeviceNET BusDeviceNET Bus DH1 or DH485 KitDH1 or DH485 Kit⇒⇒⇒⇒⇒⇒⇒⇒ ⇒⇒⇒⇒⇒⇒⇒⇒

Using:• RSLinx• 1761 Interface Devices• PM02 Cable(s)

31

ANIL MAURYA ELECTRICAL & ELECTRONICS

ENGINEER

32

ANIL MAURYA ELECTRICAL & ELECTRONICS

ENGINEER

Data Sheet Of Cables

33

34

ANIL MAURYA ELECTRICAL & ELECTRONICS

ENGINEER

� 1784-PCC driver enhanced to increase browsing performance. The node table object on the card now determines valid nodes instead of RSLinx browsing for them.

� Support added for a new item property (I.D. is 5000). This property exists only for ControlLogix items and will test an item to determine if it is boolean.

35

ANIL MAURYA ELECTRICAL & ELECTRONICS

ENGINEER

� New DeviceNet error code added for better address parsing of parameter errors.

Specific support includes:

� Date and Currency� Date and Currency

� Returning errors when values out of range

� Failing the AddItems when requested data type is invalid

36

ANIL MAURYA ELECTRICAL & ELECTRONICS

ENGINEER

37

38

� Online programming

� Offline programming

� Test and troubleshooting

39

ANIL MAURYA ELECTRICAL & ELECTRONICS

ENGINEER

40

ANIL MAURYA ELECTRICAL & ELECTRONICS

ENGINEER

41

ANIL MAURYA ELECTRICAL & ELECTRONICS

ENGINEER

� Network through any standard RJ45 Ethernet cable

� 100 Base-T Port with embedded LEDs allows � 100 Base-T Port with embedded LEDs allows connection to provide easy-to-see link transmit / receive

42

ANIL MAURYA ELECTRICAL & ELECTRONICS

ENGINEER

� Using the 1761 series adapters designed for the RSlogix platform to connect the controllogix, Compactlogix and PLC 5000 controllers allows the ultimate in flexibility between components and industry standard Ethernet and Devicenet and industry standard Ethernet and Devicenet components.

43

ANIL MAURYA ELECTRICAL & ELECTRONICS

ENGINEER

44

ANIL MAURYA ELECTRICAL & ELECTRONICS

ENGINEER

top related