Installation of 1.8 meter Satellite Dish with NPRM

Location of the 1.8 m Satellite Dish

• Some important things to take into account when placing you satellite Dish.

• Location of POE (Point of Entry)• Location of steel beams• Location for the Satellite Receiver

Location of POE

Location of Steel beams

This photo indicates the location of the post and steel beams close to the POE.The POE is within 6 feet of this Post which will give great support for this 1.8 meter Satellite Dish.

Location of Satellite Receiver

Server Room and Satellite Receiver Room. This picture indicates location of power outlets for the equipment.

Location of Satellite Receiver

This picture shows the beam structure above for running in the Dual Coax cable from the satellite dish.It also shows the direction the cable will run towards the satellite dish.

Location of Satellite Receiver

This pictures shows the direction the cable will be run to the satellite dish.

Building the 1.8 m Satellite Dish

• Layout your materials so it is easy to find the parts.

• Layout your you parts to form your non penetrating mount (NPRM).

• Lay down your rubber mats under your NPRM.• Tighten all your bolts.• Place your concrete blocks within your NPRM.

Building the 1.8 m Satellite Dish

Lay out of boxes of materials.

Building the 1.8 m Satellite Dish

Layout your parts to the NPRM, install rubber mats, and tighten the bolts.

Building the 1.8 m Satellite Dish

Insert the concrete blocks into the NPRM for support for holding down the satellite dish. This mount should have been 8 blocks each side.

Installation of Satellite Dish

• Lay 1.8 m satellite dish face down install the mounting bracket.

• Install the post mount on the mast of the NPRM.

• Install the dish to the post mount.• install the horizontal and vertical adjustments

for the dish.• Install the support arms to the dish and support

arm for the ODU.

Installation of Satellite Dish

• Install the ODU on the support arm.• Tighten all the bolts to the supports arms and

support arm for the ODU.

Installation of Satellite Dish

Bracket for mounting the satellite dish to the pole mount.

Installation of Satellite Dish

Bolt for mounting dish to Pole mount.

Installation of Satellite Dish

Vertical adjustment

Horizontal adjustment

Pole Mount

Installation of Satellite Dish

Support Arms

Installation of Satellite Dish

Installation of the ODU on the support arm.

Installation of the Dual RG-6 Cable

• Install cable up as high as possible – q-deck.• Service loops at POE, satellite dish and direct

indoor unit (DIU).• Cable tied neat with UV tie wraps outside and

tie wraps inside.• Seal RG-6 Connectors on the ODU with rubber

tape then wrapped with black tape.• Tag RX with red tape and TX with blue tape.

Installation of Dual RG-6 Cable

Service loop at POE

Installation of Dual RG-6 Cable

Service loop at Satellite Dish

Service Loop in the Server room for the DIU.

Installation of Dual RG-6 Cable

Sealed connectors on the RX and TX, also the tagging of red and blue tap.

Installation of Dual RG-6 Cable

Installation of DIU and the red and blue tape tagging on the RG-6 Cable.

Last Items

• Set the polarization on the ODU.• Peak antenna for the satellite required for

your service.• Peak and pull with the Network Operations

Centre (NOC) for Max Cross pole.• Complete the certification of DIU with service

providers servers.