gaining confidence with gd t part 1
Post on 03-Jun-2018
221 Views
Preview:
TRANSCRIPT
-
8/12/2019 Gaining Confidence With Gd t Part 1
1/24
Geometric TolerancingPMPA Technical Conference
Developing Todays Talent For Tomorrows $uccess
Corona, California
April 15, 2013
Gary K. Griffith
Session 1
-
8/12/2019 Gaining Confidence With Gd t Part 1
2/24
Gary K. Griffith
Technical Book AuthorQualityEngineeringShop Technical
42 Years Exp.AutomotiveAerospace
EngineeringManufacturingQuality
Photos Reference: Geometric TolerancingApplications and Inspection (Prentice Hall)
-
8/12/2019 Gaining Confidence With Gd t Part 1
3/24
Outline Session 1
Limitations are:1. Inspectors Knowledge / Skills 2. Available Inspection Equipment
Form TolerancesFlatnessStraightnessCircularityCylindricity
Orientation TolerancesParallelismPerpendicularity
Angularity
Form & Orientation Tolerances Interpretation & Inspection
-
8/12/2019 Gaining Confidence With Gd t Part 1
4/24
T.I.R. F.I.M.
Some Geometric Tolerance measurements are:
T.I.R. Total Indicator ReadingF.I.M. Full Indicator Movement
-
8/12/2019 Gaining Confidence With Gd t Part 1
5/24
Flatness Tolerance
Flatness
Flatness measurement is a T.I.R. (or F.I.M.) that is
achieved with a probe or dial indicator
-
8/12/2019 Gaining Confidence With Gd t Part 1
6/24
Flatness Tolerance
Leveling (Wobble) Plate Method Jack Screws Method
Surface must be leveled (optimum plane) so that the
probe sees only hills and valleys of flatness error
-
8/12/2019 Gaining Confidence With Gd t Part 1
7/24
Flatness Tolerance
Indian Pins Set
Alternative is Indian Pins. Three pins at exactly the
same height within millionths. The pins level the surface.
-
8/12/2019 Gaining Confidence With Gd t Part 1
8/24
Straightness ofSurface Elements
Applies to individual line elements at the surface, not
the axis.
-
8/12/2019 Gaining Confidence With Gd t Part 1
9/24
Straightness ofSurface Elements
Setup with two jack screws, a parallel, and a V-Block.
Jacks are used to level the line element, then a top-dead-center T.I.R.
-
8/12/2019 Gaining Confidence With Gd t Part 1
10/24
Straightness ofSurface Elements
Alternative is two equal height gage block stacks, then a bottom-dead-center T.I.R.
-
8/12/2019 Gaining Confidence With Gd t Part 1
11/24
Straightness ofan Axis - RFS
Challenging inspection. Differential measurements
are required for inspection. Two opposing indicators to trackaxial deviation
This part is acceptable
h f
-
8/12/2019 Gaining Confidence With Gd t Part 1
12/24
Straightness ofan Axis - MMC
This type of straightness could be evaluated with a
Functional Gage (as with any tolerance at MMC)
-
8/12/2019 Gaining Confidence With Gd t Part 1
13/24
Circularity (Roundness)
Roundness tolerance zone is two concentric circles.
Roundness is a radial measurement, not diametral.
-
8/12/2019 Gaining Confidence With Gd t Part 1
14/24
Precision Spindle
Circularity (Roundness)
A precision spindle (or CMM) could be used.
-
8/12/2019 Gaining Confidence With Gd t Part 1
15/24
CylindricityCylindricity combines measurement of roundness,
straightness of surface elements, and taper per side.
-
8/12/2019 Gaining Confidence With Gd t Part 1
16/24
Parallelismof a Surface
Parallelism of a Surface
Tolerance Zone
Parallelism measurement is a T.I.R. once the datumhas been mounted.
P ll li
-
8/12/2019 Gaining Confidence With Gd t Part 1
17/24
Parallelismof a Surface
Parallelism Inspection
Dial indicator is being traversed across the entiresurface. The resulting T.I.R. shall not exceed thetolerance. Flatness is automatically controlled.
P di l i
-
8/12/2019 Gaining Confidence With Gd t Part 1
18/24
Perpendicularityof a Surface
Perpendicularity of a Surface
Tolerance Zone
Perpendicularity measurement is also a T.I.R.
Flatness is inherently controlled.
-
8/12/2019 Gaining Confidence With Gd t Part 1
19/24
Perpendicularityof a Surface
Inspection
Since there is only one datum, the part must be best-fit
for secondary alignment.
P di l it
-
8/12/2019 Gaining Confidence With Gd t Part 1
20/24
Perpendicularityof a Surface
(Secondary Datum)
Perpendicularity of a Surface
Inspection
When there is a secondary datum, the part is aligned.
-
8/12/2019 Gaining Confidence With Gd t Part 1
21/24
Angularity
xx
Angularity Requirement
Tolerance Zone
Angularity measurement is also a T.I.R.
Flatness is inherently controlled.
-
8/12/2019 Gaining Confidence With Gd t Part 1
22/24
Angularity
xx
Angularity Requirement
Inspection
A Sine Bar, Sine Plate, or CMM could be used.
-
8/12/2019 Gaining Confidence With Gd t Part 1
23/24
Griffith TrainingOn-Site Tailored GD&T Training :
Basic Intermediate Advanced
Tolerance Stackup AnalysisFunctional Gage DesignInspectionQuality Courses
Consulting:
Functional Design DrawingReviewsTolerance StackupsFunctional Gage Designs
-
8/12/2019 Gaining Confidence With Gd t Part 1
24/24
Questions and Answers
griftrain@verizon.net 951-733-9678
www griffithtraining com
Need Training?
mailto:griftrain@verizon.netmailto:griftrain@verizon.net
top related