• Booster RF Cavity removed from Station 8– Removed October 3, 2011– This cavity was picked to be first for the following:

• One of the lowest for radioactivity.

• Cavity had a suspected small vacuum leak.

• Cavity had performance issues when cold.

– Shipped cavity to MI-60 for initial testing before disassembly.– Cavity moved into cave at MI-60 for high power testing.– Cavity leak checked and found to have a vacuum leak on

upstream end flange.– Temporary repair was performed to allow cavity to under go

initial testing at 15Hz.– Cavity run at 15Hz with reduced gradient to measure

temperature rise of critical components.• Stem temperature > 200 F in 15 minutes running

March 7, 2012 John Reid 2

fFermilab

Leaking Cavity End Flange

March 7, 2012 John Reid 3

fFermilab

Standard Ferrite Tuner

March 7, 2012 John Reid 4

fFermilab

Cavity End Cut Open

March 7, 2012 John Reid 5

fFermilab

Bad Tuner Stem Connection

March 7, 2012 John Reid 6

fFermilab

Burnt Tuner Cone

March 7, 2012 John Reid 7

fFermilab

Burnt Fingers on Cone

March 7, 2012 John Reid 8

fFermilab

Inside Center of Cavity

March 7, 2012 John Reid 9

fFermilab

Anode Blocking Capacitor

March 7, 2012 John Reid 10

fFermilab

Anode Blocking Capacitor

March 7, 2012 John Reid 11

fFermilab

March 7, 2012 John Reid 12

fFermilab

Std Operating Waveforms

March 7, 2012 John Reid 13

Phase Det Error – Light BlueAnode Prog – Purple – 23kVpkRF Gap Envelope – Drk BluePA Screen I - Green

fFermilab

Std Operating Waveforms

March 7, 2012 John Reid 14

FBI – YellowFBV – GreenPlate I - Blue

fFermilab

Stem Temp vs Anode Voltage

March 7, 2012 John Reid 15

fFermilab

• Parameters at 23kV anode voltage @15Hz for 12 hours.– Gradient ~52.9kV peak accelerating voltage– Blocking capacitor temperature = 140 F– High voltage filter chokes – 150 F– Inside drift tube temperature = 145 F– Drift tube temperature = 140 F– Beam tube temperature (on Mu-metal shield) = 150 F– Cavity outer shell temperature by PA = 114 F– Ceramic window outer ring temperature = 106 F– Ferrite Power removed to water = 5.9kW per tuner– Back tuner stem temperature = 165 F– Front tuner stem temperature = 175 F– Bottom tuner stem temperature = 179 F– Cavity vacuum = 1.17 x 10-7 Torr

March 7, 2012 John Reid 16

fFermilab

Conclusions

• Cavity does operate at 15Hz full gradient, BUT– Need to reduce stem temperatures – Elevated temperatures are in part due to a very small

gap (0.001 to 0.002 inches) on stem vertical connection to center section.

– Going to make a 0.005 inch tin gasket to help in sealing this high rf current connection.

• Want to do longer continuous running starting as soon as gaskets are installed.

• Consider installing cavity back in Station 8 before the end of March.

March 7, 2012 John Reid 17