eikon eng
Post on 28-Apr-2015
42 Views
Preview:
TRANSCRIPT
C ATA L O G U E 2 0 0 8
English
e i k o n .Tw o c o v e r p l a t e d e s i g n s : C l a s s i c a n d Round. Three possibilities for the applia n c e s : a n t h r a c i t e g re y, w h i t e a n d N e x t . Over two hundred functions and By-me for home automation. burglar alarm, access control and video door entry systems. Eikon in metal, solid wood, natural stone, crystal and stainless steel.
Vimar reserves the right to modify its products at any time without advance notification. Due to layout considerations, the images and drawings of the products are not in scale to each other
IndexSwitchesSwitches Socket outlets Signal reception socket outlets Signalling Protection Detection Comfortfrom page
05 39 49 61 79 83 87
By-me: home automation system General features Flush and surface mounting control units Video door entry system Home automation Burglar alarm system Access control system
from page
98 99 122 138 162 184
Installation Types of mounting Classic cover plates Round cover plates Customization
from page
192 194 196 198
1
To uch p e r f e c ti o n .Soft-action movement for the buttons. The transfer of movement from the button to the mechanism has been completely redesigned with a joint-pin system (1) protected by a worldwide patent. The standstill of the button has been cushioned with co-moulded rubber elements (2-3-4-5). The spring geometry of the moving contact of the mechanism performs a natural cushioning function, reducing its electrical recoils and wear, also thanks to a large increase in the quantity of silver of the contacts. This reconciles the safety of the elctric switching qith the smoothness of the operation. You can check the result yourselves: reduction in the movement of the button, less stand-out of the plate and a muffled sound. In short: state-of-the-art for control devices.
Cover plates. 85 colours and a wide range of combinations in five premium materials: Metal: Bright and Galvanic Wood: solid natural wood Stone: natural stone Glass: crystal Inox: stainless steel, brushed, brushed anthracite and cotton.
Laser engravings. At the back by each terminal to describe its function, on one side with commercial data and on the opposite side with technical data.
Interchangeable buttons. 1-, 2- and 3-module, with backlighting symbols and customizables
The frame. In 3 colours: grey anthracite, white and Next.
Night&day symbols. Supplied as standard or on request, even in minimum quantities. The latter are laser cut in the specific backlit area of the button. Perfectly visible by day, at night thanks to the signalling on the back, they are coloured with a warm amber light, restful and matching the displays of the electronic devices.
Plack-clack system. Hooking of the components of the light fixture, patented by Vimar. Greater structural strength, extraordinary rigidity, easily connecting and disconnecting devices at the front.
The spring geometry of the moving contact of the mechanism performs a natural cushioning function, reducing its electrical recoils and wear, also thanks to a large increase in the quantity of silver of the contacts.
2
2
3
1
4
5
Eikon anthracite: in darkness, backlighting with 230 V~
Lowered frame. The semi-transparency helps with device installation and wiring. The honeycomb structure makes it sturdy. The reduction of the volume of the light fixture to a minimum.
Eikon white: in darkness, backlighting with 24 V
Single packing in box with barcode The appliance is protected against knocks, dropping and dust and is well identified. In all cases where the methods of installation are not obvious, the appliances are equipped with an instruction sheet. The EAN 13 barcode, used by over 100 countries, is printed on every level packing and permits automatic inventory management with optical readers and computer systems connected to them.
Eikon Next: in darkness, backlighting with 230 V~
3
SwitchesSwitches ScopeSwitching on and off of ohm-inductive loads: lighting circuits: - lighting fittings (luminaires) for use incandescent lamps - lighting fittings (luminaires) for use with fluorescent lamps, with or without power factor compensation dedicated circuits for: - motor driven appliances (fans, ventilators, canopy hoods, etc.) - switches socket outlet
TECHNICAL CHARACTERISTICS Technical specificationsratedvoltage:250V~ ratedcurrent: - 10 A for push buttons - 16 AX for devices that controls circuits of fluorescent lamps with power factor compensation contactopeninggap:>3mm insulationresistance:>5M a 500 V d.c. dielectricstrength:>2000V~ minimumbreakingcapacity: 200 operations with 1,25 In, 275 V~ cos 0,3 and 200 operations with 1,2 In, 250 V~, with load of tungsten filament lamp (except for push buttons) minimumelectricallife: - 40.000 operations with In, 250 V~, cos 0,6 - 10.000 operations for 10 AX switches (5.000 for 16 AX switches) with In, 250 V~, with load of fluorescent lamps balancedandnoiselessrockingactionfor1-way,3-wayand reversing switches and push buttons
Switches with customized buttonsVimar laser technology allows to reproduce on the buttons, with absolute precision and indelebility, the following: allthesymbolsofthearticlesinthepresentcatalogue allthesymbolsandwordingsshownonpage198 symbols,wordings,logotypesortrademarksonrequest(see Customization - page 198)
Conformity to StandardsLV Directive EN 60669-1 Standard
Pre-wired signalling unit for switch visibility in the dark
Signalling unit for the signalling of the load state
20001
20001
14773
10493
Wiring diagrams for luminous 1P 1-way switches with 110 V~ or 250 V~ signalling unitsFor switch location in the dark:pilot lamp always lit
For switch location in the dark:pilot lamp unlit when the controlled load is ON
Indication of the operation state of appliances not visible from the operating point:pilot lamp lit when the controlled load is ONL N
L N
L N
4
Switches20041 20044
Blank module and cable outlet.B .B .N .N
Blank module Cable outlet20,5 11 22,3
20041 grey
20041.B white
20041.N Next
26,1 16,6 22,3
20044 grey
20044.B white
20044.N Next
20001 20001.0
1P 1-way switch 250 V~.B .N
1P 16 AX 1-way switch, lightable, replaceable button 1P 16 AX 1-way switch mechanism, lightable, to complete with 1-, 2- or 3-module button
36,15 25 22,3
20001 grey
20001.B white
20001.N Next34,6 25 22,3
20001.0
20001.2 20001.7
1P 1-way switch 250 V~.B .B .N .N
1P 16 AX 1-way switch, lightable - 2 modules 1P 16 AX 1-way switch, with diffuser - 2 modules36,15 25 44,8
20001.2 grey
20001.2.B white
20001.2.N Next36,15 25 44,8
20001.7 greySide views show the overall dimensions and the flush depth in mm Mountingboxes,framesandcoverplates,page189
20001.7.B white
20001.7.N Next
5
49
49
49
SwitchesSwitches TECHNICAL CHARACTERISTICSTechnical specifications of signalling unitsArticle 10490* 10491* 10492 10493 10492.V 10493.V 10492.AZ 10493.AZ 14772 14773 Type incandescent incandescent neon neon fluorescent fluorescent fluorescent fluorescent neon neon Supply voltage 12 V 24 V 110 V~ 250 V~ 110 V~ 250 V~ 110 V~ 250 V~ 120 V~ 230 V~ W 0,5 W max 0,5 W max 0,5 W max 0,5 W max 0,5 W max 0,5 W max 0,5 W max 0,5 W max 0,5 W max 0,5 W max Colour white white red red green green blue blue red redA 1,5 F 400 V~ capacitor should be connected in parallel to neon or fluorescent signalling units to avoid self-ignition in special circuits.
Wiring diagrams for luminous 2P 1-way switches with 110 V~ or 250 V~ signalling unitFor switch location in the dark:pilot lamp always lit
Indication of the operational state of appliances not visible from the operating point:pilot lamp lit when the controlled load is ONL N
L N
Pre-wired signalling unit for switch location in the dark
Signalling unit for the signalling of the load state
20005
20005
14773
10493
Wiring diagrams of luminous 1P 2-way switches with 110 V~ or 250 V~ signalling unitFor switch location in the dark:pilot lamp always lit
For switch location in the dark:pilot lamp unlit when the controlled load is ONL N
Indication of the operation state of appliances not visible from the operating point:pilot lamp lit when the controlled load is ONL N
L N
6
Switches20015 20015.0 20015.2
2P 1-way switch 250 V~.B .N .B .N
2P 16 AX 1-way switch, lightable, replaceable button 2P 16 AX 1-way switch mechanism, lightable, to complete with 1-, 2- or 3-module button 2P 16 AX 1-way switch, lightable - 2 modules34,6 25 22,3
36,15 25 22,3
20015.0
49
20015 grey
20015.B white
20015.N Next
36,15 25 22,3
20015.2 grey 20005 20005.0 20005.2 20005.7
20015.2.B white
20015.2.N Next
1P 2-way switch 250 V~.B .N .B .B .N .N 1P 1P 1P 1P
16 16 16 16
AX AX AX AX
2-way 2-way 2-way 2-way34,6 25
switch, lightable, replaceable button switch mechanism, lightable, to complete with 1-, 2- or 3-module button switch, lightable - 2 modules switch, with diffuser - 2 modules36,15 22,3 25 22,3
20005.0
49
20005 grey
20005.B white
20005.N Next
36,15 25 22,3
20005.2 grey
20005.2.B white
20005.2.N Next
20005.7 grey
20005.7.B white
20005.7.N Next
20013 20013.0 20013.2
1P reversing switch 250 V~.B .N .B .N
1P 16 AX reversing switch, lightable, replaceable button 1P 16 AX reversing switch mechanism, lightable, to complete with 1-, 2- or 3-module button 1P 16 AX reversing switch, lightable - 2 modules34,6 25 22,3 36,15 25 22,3
20013.0
49
20013 grey
20013.B white
20013.N Next
34,6 25 22,3
20013.2 greySide views show the overall dimensions and the flush depth in mm Mountingboxes,framesandcoverplates,page189
20013.2.B white
20013.2.N Next
7
49
SwitchesSwitches 1P push buttonsPre-wired signalling unit for switch location in the dark Signalling unit for the signalling of the load state Wiring diagram of luminous 1P push button with 110 V~ or 250 V~ signalling unitFor switch location in the dark:20008 20008pilot lamp always lit
TECHNICAL CHARACTERISTICS
L N
14773
10493
8
Switches20008 20008.0 20008.7
1P push button 250 V~.B .N .B .N
1P NO 10 A push button, lightable, replaceable button 1P NO 10 A push button mechanism, lightable, to complete with 1-, 2- or 3-module button 1P NO 10 A push button, with diffuser - 2 modules34,6 25 22,3
36,15 25 22,3
20008.0
49
20008 grey
20008.B white
20008.N Next
36,15 25 44,8
20008.7 grey
20008.7.B white
20008.7.N Next
20008.2 20008.2.C 20008.2.L 20008.2.P
1P push button 250 V~.B .B .B .B .N .N .N .N
1P 1P 1P 1P
NO NO NO NO
10 10 10 10
A A A A
push push push push
button, button, button, button,
lightable - 2 modules lightable, bell symbol - 2 modules lightable, light symbol - 2 modules lightable, key symbol - 2 modules
36,15 25 44,8
20008.2 grey
20008.2.B white
20008.2.N Next
20008.2.C grey
20008.2.C.B white
20008.2.C.N Next
36,15 25 44,8
20008.2.L grey
20008.2.L.B white
20008.2.L.N Next
20008.2.P grey
20008.2.P.B white
20008.2.P.N Next
20010 20010.0
1P push button 250 V~.B .N
1P NC 10 A push button, lightable, replaceable button 1P NC 10 A push button mechanism, lightable, to complete with 1-, 2- or 3-module button34,6 25 22,3 36,15 25 44,8
20010.0
49
20010 grey
20010.B white
20010.N Next
Side views show the overall dimensions and the flush depth in mm Mountingboxes,framesandcoverplates,page189
9
49
SwitchesSwitches TECHNICAL CHARACTERISTICSButton mounting Button removing
20001.0
20021
Mechanism
1-module button
2-module button
3-module button
20021 20026 20031 20021.C 20021.L 20021.P 20021.99
Interchangeable 1-module button.B .B .B .B .B .B .B .N .N .N .N .N .N .N
Lightable button Button with diffuser, lightable Customizable button with standard symbol (see Standard symbols and wordings*) or given by customer, lightable Button with bell symbol, lightable Button with light symbol, lightable Button with key symbol, lightable Button with O I symbol, lightable, for 20015.0 2P 1-way switch mechanism
20021 grey
20021.B white
20021.N Next
20026 grey
20026.B white
20026.N Next
20031 grey
20031.B white
20031.N Next
20021.C grey
20021.C.B white
20021.C.N Next
20021.L grey
20021.L.B white
20021.L.N Next
20021.P grey
20021.P.B white
20021.P.N Next
20021.99 20021.99.B 20021.99.N Next white grey
10
Switches20022 20027 20032
Interchangeable 2-module button.B .B .B .N .N .N
Lightable button Button with diffuser, lightable Customizable button with standard symbol (see Standard symbols and wordings*) or given by customer, lightable
20022 grey
20022.B white
20022.N Next
20027 grey
20027.B white
20027.N Next
20032 grey
20032.B white
20032.N Next
20022.C 20022.L 20022.P 20022.99
Interchangeable 3-module button.B .B .B .B .N .N .N .N Button Button Button Button with with with with
bell symbol, lightable light symbol, lightable key symbol, lightable O I symbol, lightable, for 20015.0 2P 1-way switch mechanism
20022.C grey
20022.C.B white
20022.C.N Next
20022.L grey
20022.L.B white
20022.L.N Next
20022.P grey
20022.P.B white
20022.P.N Next
20022.99 grey
20022.99.B white
20022.99.N Next
Side views show the overall dimensions and the flush depth in mm Mountingboxes,framesandcoverplates,page189
* Customization: see page 198
11
SwitchesSwitches20023 20028
Interchangeable 3-module button.B .B .N .N
Lightable button Button with diffuser, lightable
20023 grey
20023.B white
20023.N Next
20028 grey
20028.B white
20028.N Next
Interchangeable 3-module button20033 .B .N
Customizable button with standard symbol (see Standard symbols and wordings*) or given by customer, lightable
20033 grey
20033.B white
20033.N Next
12
SwitchesInterchangeable 2-module button20023.C 20023.L .N .N Button with bell symbol, lightable Button with light symbol, lightable
20023.C grey
20023.C.B white
20023.C.N Next
20023.L grey
20023.L.B white
20023.L.N Next
20023.P 20023.99
Interchangeable 3-module button.B .B .N .N
Button with key symbol, lightable Button with O I symbol, lightable, for 20015.0 2P 1-way switch mechanism
20023.P grey
20023.P.B white
20023.P.N Next
20023.99 grey
20023.99.B white
20023.99.N Next
Side views show the overall dimensions and the flush depth in mm Mountingboxes,framesandcoverplates,page189
13
SwitchesSwitches TECHNICAL CHARACTERISTICS Lightable name-plate push buttonName-plate opening Lamp and customized cardboard assemblyBody E10 lamp Opaline diffuser Cardboard Front
Technical specications of lampsArticle 14775 14778 14779 Type incandescence neon neon Voltage 24 V~ 230 V~ 230 V~ W 1,2 W 0,5 W 0,5 W Colour white red red
14
Switches1P name-plate push button20050 .B .N 1P NO 10 A lightable name-plate push button for E10 10x28 mm 1 W max lamp - 2 modules.Supplied without lamp37,65 26,5 44,8
20050 grey
20050.B white
20050.N Next
20052 20053
1P cord-operated push button.B .B .N .N
1P NO 10 A cord-operated push button, with 1,5 m cord 1P NC 10 A cord-operated push button, with 1,5 m cord37,3 25,5 22,3
20052 20053 grey
20052.B 20053.B white
20052.N 20053.N Next
20056.33 20056.34 20058
Additional 1P push button 250 V~.B .B .B .N .N .N
1P 10 A push button, NO+ NC contacts, OFF symbol 1P 10 A push button, NO+ NC contacts, ON symbol Two independent push buttons, 1P NO + 1P NC 10 A, ON and OFF symbols39 29,5 22,3
20056.33 grey
20056.33.B white
20056.33.N Next
20056.34 grey
20056.34.B white
20056.34.N Next
39 29,5 22,3
20058 greySide views show the overall dimensions and the flush depth in mm Mountingboxes,framesandcoverplates,page189
20058.B white
20058.N Next
15
SwitchesSwitches Assembly
TECHNICAL CHARACTERISTICS
Push button + indicator unit for signalling unit
The terminals allow the signalling unit cable connection
A 1,5 F 400 V~ capacitor should be connected in parallel to neon or fluorescent signalling units to avoid self-ignition in special circuits
Technical specications of signalling unitsColour of indicator light white white orange orange red red green green blue blue Signalling unit 10490* 10491* 10490* 10491* 10492 10493 10492.V 10493.V 10492.AZ 10493.AZ Type incandescent incandescent incandescent incandescent neon neon uorescent uorescent uorescent uorescent Supply voltage 12 V 24 V 12 V 24 V 110 V~ 250 V~ 110 V~ 250 V~ 110 V~ 250 V~ W 0,5 W max 0,5 W max 0,5 W max 0,5 W max 0,5 W max 0,5 W max 0,5 W max 0,5 W max 0,5 W max 0,5 W max Colour of indicator light white white white white red red green green blue blue Diffuser colour white white orange orange red red green green white white
N.B. Colour of indicator light = colour of the signalling unit + colour of the diffuser
16
SwitchesAdditional 1P push button 250 V~20066 .B .N Two independent push buttons, 1P NO + 1P NO 10 A.reversing motors (roller blind, gates etc.) Allow the simultaneous closing of the two circuits and are thus not suitable for
39 29,5 22,3
20066 grey
20066.B white
20066.N Next
20068.A 20068.B 20068.R 20068.V
1P push button 250 V~ with indicator unit.B .B .B .B .N .N .N .N
1P NO 10 A push button + indicator unit for signalling unit, orange diffuser. As above, white diffuser As above, red diffuser As above, green diffuser
Supplied without signalling unit.
38,5 29 22,3
20068.A grey
20068.A.B white
20068.A.N Next
20068.B grey
20068.B.B white
20068.B.N Next
38,5 29 22,3
20068.R grey
20068.R.B white
20068.R.N Next
20068.V grey
20068.V.B white
20068.V.N Next
Special switch 250 V~20073 .B .N
16 AX 1-way switch, NO + NC contacts, ON and OFF symbols, lightable, replaceable button36,15 25 22,3
20073 grey
20073.B white
20073.N Next
Side views show the overall dimensions and the flush depth in mm Mountingboxes,framesandcoverplates,page189
17
SwitchesSwitches TECHNICAL CHARACTERISTICS Switches with directional arrowsThese switches can be used for the direct control of motor driven loads, i.e. roller blinds, gates, etc. Interlocked buttons, or those with non-simultaneous closing, may control two independent circuits and are normally combined with relays, to allow the activation of motor driven pulses (i.e. motors for blinds, gates, etc.)
Key-operated switchesThese switches are particularly suitable for preventing outsiders from unauthorized operations. Two kinds of key-operated switches are available: switches with the same lock and key (000 unified code), which allows the user to operate all the switches with the same key; switches with different locks and keys, to restrict the possibility of operations according to particular needs of the users. They are all delivered with two keys. The key is removable when the switches are either in the ON or in the OFF position. By request the switches can be supplied with the key removable in the ON position only. A serigraphy on the front of the switches indicates the type of key removing:0 I 0 I
= key removable both in ON and OFF position = key removable in OFF position, only
IMPORTANT Vimar has a range of 100 different combination keys used at random in every produced lot, this guaranteeing that each packing unit of 20 pieces will be provided with 20 different combination keys.
18
Switches20060 20062
Switch with directional arrows 250 V~.B .B .N .N
2P 10 AX (6 terminals) two-button switch, with directional arrows and central OFF position Two interlocked push buttons, 1P NO + 1P NO 10 A, with directional arrows43,5 34 22,3
20060 grey
20060.B white
20060.N Next
39 29,5 22,3
20062 grey
20062.B white
20062.N Next
20082 20082.CU 20083 20083.CU
2P key-operated switch 250 V~.B .B .B .B .N .N .N .N
2P 16 AX 1-way switch, key removable in 0 (OFF) position, only As above, 000 unified key 2P 16 AX 1-way switch, key removable in both positions As above, 000 unified key43,5 33,5 22,3
20082 20082.CU grey
20082.B 20082.CU.B white
20082.N 20082.CU.N Next43,5 33,5 22,3
20083 20083.CU grey
20083.B 20083.CU.B white
20083.N 20083.CU.N Next
2P key-operated switch 250 V~20086 .B 20086.CU .B .N .N
2P NO 16 A push button, key removable in 0 (OFF) position, only As above, 000 unified key43,5 33,5 22,3
20086 20086.CU grey
20086.B 20086.CU.B white
20086.N 20086.CU.N Next
Side views show the overall dimensions and the flush depth in mm Mountingboxes,framesandcoverplates,page189
19
SwitchesTouch switches ScopeThe touch switches make it possible to control (switch on, off and adjust) loads such as incandescent lights, fluorescent lights, with and without power factor correction, dedicated circuits for motorized appliances and controlled sockets (electronic switches only). Thanks to the capacitive response microprocessor technology (Vimar patent), with extra-flat profile, total absence of moving parts and the silent operation, these devices are an innovative and prestigious alternative to conventional controls such as 1-way switches, 2-way switches, etc.
TECHNICAL CHARACTERISTICS
Conformity to StandardsLV Directive EMCDirective EN 60669-2-1 Standard
Electronic touch switch with relay output Technical specificationsSupplyvoltage:230V~50-60Hz Relayoutput:6A230V~ Operating:monostableorbistable Pilotlampforvisibilityindarkness Operatingtemperature:-5C-+35C
- operation from several points using 20123 remote control touch buttons or NO push buttons (max range 100 m); do not use buttons with built-in indicator unit. Dip-switch: - both OFF: monostable operating; - both ON: bistable operating.
Controllable loadsResistiveloads :6A Halogenandincandescentlamps : 1000 W Ferromagnetictransformers : 1000 VA Electronictransformers : 700 VA Fluorescentandcompactfluorescentlamps:60W Motori : 1,8 A cos 0,6 20120 - Wiring diagramL N
dip-switch
OperatingFrontLED:alwayson Controls: - touch button: controls are made by lightly placing a finger on the front of the device;Control from several ppoints with NO push buttons
Electronic touch switch for incandescent lamps Technical specificationsSupplyvoltage:230V~50-60Hz Pilotlampforvisibilityindarkness Externalfuse:F1,6AH250V~ Operatingtemperature:-5C-+35C
20121 - Wiring diagramL N
ConnectionThe connection should be made together with a 20416 fuse carrier with a quick-acting fuse with high breaking capacity type F1,6AH 250 V~
20416
Controllable loads Operating
Halogenandincandescentlamps : 40-300 W FrontLED:alwayson Controls: - touch button: controls are made by lightly placing a finger on the front of the device - operation from several points using 20123 remote control touch buttons or NO push buttons (max range 100 m); do not use buttons with built-in indicator unit. Operating:bistable
Control from several points with touch switch for remote control or NO push buttons
Thedeviceisconnectedinserieswiththeloadtocontrol,in addtion, it can substitute a normal switch.
20
Touch switchesElectronic touch switch with relay output20120 .B .N Electronic switch with NO 6 A 230 V~ relay output, control with built-in touch sensor or from NO peripheral push buttons, monostable or bistable operating, visible in darkness, supply voltage 230 V~ 50-60 Hz
46,5 37 22,3
20120 grey
20120.B white
20120.N Next
Electronic touch switch for incandescent lamps20121 .B .N
Electronic switch, supply voltage 230 V~ 50-60 Hz for 40-300 W incandescent lamps, control with built-in touch sensor or from NO peripheral push buttons, bistable operating, visible in darkness
46,5 37 22,3
20121 grey
20121.B white
20121.N Next
Side views show the overall dimensions and the flush depth in mm Mountingboxes,framesandcoverplates,page189
21
49
49
SwitchesTouch switches TECHNICAL CHARACTERISTICSNotsuitableformotorcontrol(e.g. exhaust fans, extractors). For installations with 2 dimmers in the same box the loads controllable by each dimmer should be reduced so that their total does not exceed the values indicated above.
Dimmer for resistive and inductive loads Technical specificationsSupplyvoltage:230V~50Hz. Switch on, regulation and switch off through touch sensor, 20123 push button for remote control or not luminous NCpush buttons. Lighting level is saved when). switch off (unless there is a blackout) Softstart:ensuresagraduallightingfromzerotomaximumor preset lighting levels. Softend:ensuresagradualpassagefromlighttodark. Control and regulation from several points with 20123 push buttons for remote control or NO peripheral push buttons. Controlandregulationwithtouchsensorandadditionalloads with SLAVE device. Connectionforremotecontrolwith20120and20121. Overhetaingprotectionwithflashingblowoutdetector. MASTER-SLAVEfunction:solongasthemaximumpermissibleloadofeachdimmerisnotexceeded,asingleMASTER dimmer can be combined with up to 4 SLAVE 20161 dimmers for a total maximum load of 2500 W (VA) corresponding to 500 W/VA max connected to each of the 5 dimmers. Operatingtemperature:-5C-+35C.
Operating.thedeviceisswitchedonandoffbylightlyplacingafingeron the front and then taking it off. Itisregulatedbykeepingyourfingeronthefrontofthedevice, to reverse the direction of adjustment, take your finger off and then place it back on again immediately. When maximum or minimum load is reached, regulation stops and can be inverted by taking your finger off and placing it back on again.
20125 - Wiring diagramL N 20125 20123
20416
ConnectionsThe connection should be made with 20416 fuse carrier with a quick-acting fuse with high breaking capacity type F2,5AH 250 V~ (07050.HF.2.5) as shown in the wiring diagram: controlandregulationwithtouchswitchorfromseveralpoints with touch switch for remote control 20123 or parallel connected NO push buttons (see figure 1). do not use NO push buttons with built-in indicator unit; Controlandregulationwithtouchsensorandadditionalloads with SLAVE device 20161 (max 4) (figure 2).
20125 - Wiring diagramInordertooperatecorrectlythelengthofeachconnectionbetweentheMASTER dimmer and SLAVE dimmer or NO push buttons should not exceed 100 m.L N 20125 SLAVE
Controllable loads.halogenandincandescentlamps : 40-500 W. ferromagnetictrasformersforlow-voltagehalogenlamps : 40-500 VA. electronictransformersVIMAR01860.60max4,or01860.105 max 3. inductive response electronic transformers : 40-300 VA (300 VA max up to 3 transformers, 240 VA max up to 4 transformers; do not connect more than 4 transformers).
20416
20416
20161
Push button for remote control Technical specificationssupplyvoltage:230V~50-60Hz. pilotlampforvisibilityindarkness. operatingtemperature:-5C-+35C.
20123 - Wiring diagramL N 20120 20123
Controllable loads.Connected to 20120, 20121 and 20125 allows the remote control of the controlled loads.
Operating.FrontLED:alwayson. Controls:fronttouchsensor;controls are made by lightly placing a finger on the front of the device Monostableoperating.
22
Touch switchesTouch dimmer for resistive and inductive loads20125 .B .N Dimmer, supply voltage 230 V~ 50 Hz for 40-500 W incandescent lamps, 40-500 VA ferromagnetic transformers and 40-300 VA L inductive response electronic transformers, control and regulation with built-in touch sensor or from NOperipheralpushbuttons,MASTERfunction,MOSFET+TRIACtechnology,visibleindarkness. Not suitable for installation in Isoset IP44 and IP55 enclosures51 41,5 22,3
20125 grey
20125.B white
20125.N Next
Touch push button for remote control20123 .B .N
Push button for remote control with touch sensor, visible in darkness, supply voltage 230 V~ 50-60 Hz46,5 37 22,3
20123 grey
20123.B white
20123.N Next
Side views show the overall dimensions and the flush depth in mm Mountingboxes,framesandcoverplates,page189
23
49
49
SwitchesDimmers TECHNICAL CHARACTERISTICS Dimmers 20160 - 20161 Technical specificationsSwitch on, regulation and switch off through built-in push button or non-luminous NC push buttons. Lighting level is saved when switched off (unless there is a blackout). Softstart:ensuresagraduallightingfromzerotomaximumor preset lighting levels. Softend:ensuresagradualpassagefromlighttodark. Protectionagainstshort-circuitwhenswitchonandoverriding with blow-out indication MASTER-SLAVE function: so long as the maximum permissibleloadofeachdimmerisnotexceeded,asingleMASTER dimmer can be combined with up to 4 SLAVE dimmers for a total maximum load of 2500 W (VA) corresponding to 500 W/VA max connected to each of the 5 dimmers. SLAVEdimmerhastobeconnectedtoaMASTERdimmerto operate.
20160 - Control and regulation from several points with NO push buttons LN
P
20416
20160
Controllable loadshalogen and incandescent lamps: 40-500 W 230 V~ 50 Hz. ferromagnetic transformers for low-voltage halogen lamps: 40-500 VA 230 V~ 50 Hz. electronictransformersVIMAR01860.60max4,or01860.105 max 3
20161 - Control and regulation with SLAVE dimmerL N
Conformity to StandardsLV Directive EMCDirective EN 60669-2-1 StandardS
20416
Dimmer 20162 Technical specificationsSwitch on, regulation and switch off through built-in push button or non-luminous NC push buttons. Lighting level is saved when switched off (unless there is a blackout). Softstart:ensuresagraduallightingfromzerotomaximumor preset lighting levels. Softend:ensuresagradualpassagefromlighttodark. Protectionagainstshort-circuitwhenswitchonandoverriding with blow-out indication.
20160 Master
20416
20161 Slave
For a correct operating the distance betweenMASTER and SLAVE dimmers or NO push buttons should not to exceed 100 m.
Controllable loadselectronictransformersVIMAR01860.60max 5or 01860.105 max 3 or capacitive response electronic transformers C : 40300 VA 230 V~ 50 Hz (max 5 transformers). 20162 - Control and regulation from several points with NO push buttonsL N
Operatingthedeviceisswitchedonandoffbylightlyplacingafingeron the front and then taking it off. Itisregulatedbykeepingyourfingeronthefrontofthedevice, to reverse the direction of adjustment, take your finger off and then place it back on again immediately. When maximum or minimum load is reached, regulation stops and can be inverted by taking your finger off and placing it back on again.
20416
20162
Conformity to StandardsLV Directive EMCDirective EN 60669-2-1 Standard
24
DimmersDimmer20160 20161 .B .B .N .N Dimmer, supply voltage 230 V~ 50 Hz for 40-500 W incandescent lamps, 40-500 VA ferromagnetic transformers and 40-300 VA L inductive response electronic transformers, control and regulation with built-in push button or from peripheralNOpushbuttons,MASTERfunction,MOSFET+TRIACtechnology,visibleindarkness. SLAVE dimmer, supply voltage 230 V~ 50 Hz for 40-500 W incandescent lamps, 40-500 VA ferromagnetic transformers and 40-300 VA L inductiveresponseelectronictransformers,controlfrom20160dimmer,MOSFET+TRIACtechnology, visible in darkness. Not suitable for installation in Isoset IP44 and IP55 enclosures52,6 41,5 22,3
Not suitable for installation in Isoset IP44 and IP55 enclosures
20160 grey
20160.B white
20160.N Next
51 41,5 22,3
20161 grey
20161.B white
20161.N Next
20162
Dimmer
.B
.N
Dimmer, supply voltage 230 V~ 50 Hz for 40-300 VA capacitive response electronic transformers, control and C regulationwithbuilt-inpushbuttonorfromperipheralNOpushbuttons,MOSFETtechnology,visibleindarkness.Not suitable for installation in Isoset IP44 and IP55 enclosures52,6 41,5
22,3
20162 grey
20162.B white
20162.N Next
Controllable loads
Charact. controllable transformer L
20160 MASTER 40 - 500 W 40 - 500 VA 40 - 300 VA
20161 SLAVE 40 - 500 W 40 - 500 VA 40 - 300 VA
20162
40 - 300 VA
NOTE Theconnectionshouldbemadewithfusecarrierwithquickacting fuse with high breaking capacity type F2,5AH 250 V~ (07050.HF.2.5) as shown in the diagrams. Installation of 2 dimmers in the same mounting box, the loads controlled by each dimmer must be reduced so that their total does not exceed the indicated values.
C
Side views show the overall dimensions and the flush depth in mm Mountingboxes,framesandcoverplates,page189
25
49
49
49
SwitchesDimmers TECHNICAL CHARACTERISTICS20148 - Control and regulation from several points with NO push buttons LN
Dimmers 20148 - 20149 Technical specificationsSwitch on, regulation and switch off through built-in push button or non-luminous NC push buttons. Lighting level is saved when switched off (unless there is a blackout). Softstart:ensuresagraduallightingfromzerotomaximumor preset lighting levels. Softend:ensuresagradualpassagefromlighttodark. Protectionagainstshort-circuitwhenswitchonandoverriding with blow-out indication MASTER-SLAVE function: so long as the maximum permissible load of each dimmer is not exceeded, a singleMASTER pdimmer can be combined with up to 4 SLAVE dimmers for a total maximum load of: - 2500 W / 1500 VA at 120 V~ 50-60 Hz, corresponding to 500 W / 300 VA max connected to each of the 5 dimmers; - 5000 W / 2500 VA at 230 V~ 50-60 Hz, corresponding to 1000 W / 500 VA max connected to each of the 5 dimmers. TRIACtechnology. SLAVEdimmerhastobeconnectedtoaMASTERdimmerto operate.
20416
20148
20149 - Control and regulation with SLAVE dimmerL N
20416
20416
20148
20149
Operatingthedeviceisswitchedonandoffbylightlyplacingafingeron the front and then taking it off. Itisregulatedbykeepingyourfingeronthefrontofthedevice, to reverse the direction of adjustment, take your finger off and then place it back on again immediately. When maximum or minimum load is reached, regulation stops and can be inverted by taking your finger off and placing it back on again NOTE Theconnectionshouldbemadewithfusecarrierwithquickacting fuse with high breaking capacity type F5AH 250 V~ (07050.HF.5). Installation of 2 dimmers in the same mounting box, the loads controlled by each dimmer must be reduced so that their total does not exceed the indicated values.
Controllable loadsHalogenandincandescentlamps: 40-500 W 120 V~ 50-60 Hz; 40-1000 W 230 V~ 50-60 Hz. Ferromagnetictransformersforlow-voltagehalogenlamps: 40-300 VA 120 V~ 50-60 Hz; 40-500 VA 230 V~ 50-60 Hz. Notsuitableformotorcontrol(e.g. exhaust fans, extractors).
Electronic transformer - 01860.60Electronic transformer for extra low-voltage halogen lamps, 20-60 W, 12 V~ (SELV) output, supply voltage 230-240 V~ 50-60 Hz
Conformity to StandardsLVDirective,EMCDirective EN 61347-1, EN 61347-2-2, EN 61547, EN 55015, EN 61000-3-2, EN 61000-3-3 Standards
Electronic transformer - 01860.105 Electronic transformer for extra low-voltage halogen lamps, 20-105 W, 12 V~ (SELV) output, supply voltage 230-240 V~ 50-60 Hz Technical specificationsSELV-equivalent IP20independenttransformer Protectiveterminalcoverandcord-grip Oppositeoutetandinletterminals Max.permittedambienttemperature50C(ta)for01860.60 and40C(ta)for01860.105 Max.permittedambienttemperatureonexternalsurface:70C Dimensions:39x149x27mm
Electronic transformer wiring diagramN L L N
01860...12 V Lamp
230-240 V~
26
DimmersDimmer*20148 *20149 .B .B .N .N Dimmer, supply voltage 120-230 V~ 50-60 Hz for 40-500/40-1000 W incandescent lamps and 40-300/40-500 VA ferromagnetic transformers, control and regulation with built-in push button or from peripheral NO push buttons, MASTERfunction,TRIACtechnology,visibleindarkness SLAVE dimmer, supply voltage 120-230 V~ 50-60 Hz for 40-500/40-1000 W incandescent lamps and 40-300/40-500 VA ferromagnetic transformers, control from 20148 dimmer, TRIAC technology, visble in darkness
52,4 41,5 22,3
20148 grey
20148.B white
20148.N Next51 41,5 22,3
20149 grey
20149.B white
20149.N Next
Electronic transformer01860.60 01860.105
Dimmerable electronic transformer for extra low voltage halogen lamps, 20-60 W, 12 V~ (SELV) output, supply voltage 230-240 V~ 50-60 Hz Dimmerable electronic transformer for extra low voltage halogen lamps, 20-105 W, 12 V~ (SELV) output, supply voltage 230-240 V~ 50-60 Hz
01860.60
01860.105
Side views show the overall dimensions and the flush depth in mm Mountingboxes,framesandcoverplates,page189
* Only for Countries not members of the EU
27
49
49
SwitchesInfrared switches TECHNICAL CHARACTERISTICSFront viewInfrared receiver
20172 Infrared receiver with 6 A 230 V~ relay output Technical specificationsSupplyvoltage:230V~50-60Hz Operating:monostableandbistable OperatingstatusLED Infraredcontrol,RC5protocol Operatingtemperature:-5C-+35C
LED
Button
Controllable loadsResistiveloads :6A Incandescentandhalogenlamps : 1000 W Ferromagnetictransformers : 1000 VA Electronictransformers : 700 VA Fluorescentandcompactfluorescentlamps:60W Motors : 1,8 A cos 0,6 Control from several points with NO push buttonsL N
Conformity to StandardsLV Directive EMCDirective EN 60669-2-1 Standard
20172 20172.120
20172.120 Infrared receiver with 6 A 120 V~ relay output Technical specificationsSupplyvoltage:120V~50-60Hz Operating:monostableandbistable OperatingstatusLED Infraredcontrol,RC5protocol Operatingtemperature:-5C-+35C Connections with additional receiversButton mode
L N
Controllable loadsResistive loads :6A Incandescent and halogen lamps : 500 W Ferromagnetic transformers : 500 VA Electronic transformers : 350 VA Motors : 1,8 A cos 0,6
20172 - 20172.120 OperatingSwitchon/offwith: - button on the front of the device; - control from several point with NO push buttons (max. range 100 m); ndo not use push buttons with built-in indicator unit; - infrared operation with button on remote control. Operatingstatusindication(tobesetatthetimeoftheconfiguration); Monostableoperation(buttonmode)confirmedbyLED:LED stays on steady for 10 seconds at the start, then flashes 3 times and monostable operation is enabled Bistableoperation(stepmode)confirmedbyLED:LEDstays off for 10 seconds at the start, then flashes 3 times and bistable operation is enabled ProgrammableflashingLED Toincreasethereceptionrange,connectadditionalreceiversL NStep mode
Monostable 20172 20172.120
Monostable 20172 20172.120
Bistable 20172 20172.120
Monostable 20172 20172.120
01849 - Remote control technical specificationsThe infrared remote control operates like a little full option control unit. No dip-switch to set but only 4 channels, that allow an easy setting of the receivers, through RC5 protocol transmission. This type of data capture permits the remote control to control any other appliances.
28
Infrared switchesInfrared receiver20172 .B *20172.120 .B .N Infrared switch, NO 6 A 230 V~ output relay, control with built-in button, from 01849 remote control from peripheral NO push buttons, monostable or bistable function, visible in darkness, supply voltage 230 V~ 50-60 Hz Infrared switch, NO 6 A 120 V~ output relay, control with built-in button, from 01849 remote control from peripheral NO push buttons, monostable or bistable function, visible in darkness, supply voltage 120 V~ 50-60 Hz
.N
46,5 37 22,3
20172 grey
20172.B white
20172.N Next46,5 37 22,3
20172.120 grey
20172.120.B white
20172.120.N Next
Infrared remote control01849
14-channel infrared remote control, supply with AAA LR03 1,5 V battery. Supplied without battery
01849
Side views show the overall dimensions and the flush depth in mm Mountingboxes,framesandcoverplates,page189
* Only for Countries not members of the EU
29
49
49
SwitchesInfrared switches TECHNICAL CHARACTERISTICS20173 - Front view
20173 - Infrared receiver for roller blinds Technical specificationsSupplyvoltage:230V~50-60Hz Operating:monostable,bistableorbistablewithtimedOFF Infraredcontrol,RC5protocol Operatingtemperature:-5C-+35C
UP-button LED DOWN-button
IR-receiver LED
Controllable loadsResistiveloads :4A Motors : 2 A cos 0,6
OperatingOpensandclosesrollerblindswith: - 2 buttons on the front of the device; - control dfrom several points with 2 NO push buttons (max. range 100 m); do not use with built-in indicator unit; - infrared control with 2 remote control buttons (up and down buttons). Operating status indication (to be set at the time of the configuration); Monostable, bistable, bistable with timed OFF, confirmed by LED ProgrammableflashingLED. 20173 - Control from peripheral NO push buttonsL N
Conformity to StandardLV Directive EMCDirective EN 60669-2-1 Standard
M
M
Supplyvoltage:230V~50Hz Loadon,regulationandoff,withbuilt-inbutton,with01849infrared remote control or NO non-luminous push buttons connected in parallel. Storesthesetregulationwhentheloadisswitchedoff(except for power failure) Softstart:slowlybringstheloadsupfromofftomaximumor to the regulated setting; Softend:slowlybringstheloaddownfromontooff; ProtectionagainstshortcircuitsatonwithflashingLEDwarning; Overheatingwithflashingindicatorunit MASTER-SLAVEfunction:solongasthemaximumpermissibleloadofeachdimmerisnotexceeded,asingleMASTER device can be combined with up to 4 SLAVE 20161 dimmers for a total maximum load of 2450 W (VA) Infraredswitch,RC5protocol Operatingtemperature:-5C-+35C Controllable loads Incandescentandhalogenlamps : 40-450 W Ferromagnetic transformers for low-voltage halogen lamps : 40-450 VA ElectronictransformersVIMAR01860.60max4,or01860.105 max 3 Inductive response electronic transformers : 40-300 VA 230 V~ 50 Hz (300 VA max up to 3 transformers, 240 VA max up to 4 transformers; do not connect more then 4 transformers) Notsuitableformotorcontrol(e.g.exhaustfans,extractors)
20175 - Infrared receiver with dimmer Technical specifications
To regulate the load, hold down the button on the unit or the
remote control; to reverse the direction of regulation, release the button and then hold it down again. When the maximum or mini-mum value of the load is reached, the regulation stops and can be reversed by releasing and then holding down the button again.
Connections
Install the device with a 20416 fuse carrier with fast blow-out fuse
with high-breaking capacity F 2,5 AH 250 V~ (07050.HF.2,5) type.
Conformity to StandardsLV Directive EMCDirective EN 60669-2-1 Standard
20175 - Front viewInfrared receiver
LED
Button
20175 - SLAVE and NO push buttons connectionsL N SLAVE
Operating
Loads can be switched on and off by briefly pressing one of
the connected buttons, the button on the unit itself or the button on the remote control assigned to the receiver.
20416
20416
20175
20161
For a correct operating the distance between MASTERand SLAVE dimmers or NO push buttons should not to exceed 100 m.
30
Infrared switchesInfrared receiver20173 .B .N Infrared receiver with 4 A 230 V~ relay output for roller blinds, control with built-in push button, from 01849 remote control or from peripheral NO push buttons, monostable and bistable operating, visible in darkness, supply voltage 230 V~ 50-60 Hz - 2 modules46,5 37 44,8
20173 grey
20173.B white
20173.N Next
Infrared receiver20175 .B
.N
Infrared receiver with dimmer, supply voltage 230 V~ 50 Hz for 40-450 W incandescent lamps, 40-450 VA ferromagnetic transformers and 40-300 VA inductive response electronic transformers, control and regulation with built-in push L button,from01849remotecontrolandfromperipheralNOpushbuttons,MASTERfunction,MOSFET+TRIACtechnology, visible in darkness. Not suitable for installation in Isoset IP44 and IP55 enclosures
51 41,5
20175 grey
20175.B white
20175.N Next
20175 - Example of use
Controllable loads
Charact. controllable transformer
20175 MASTER
20161 SLAVE
40 - 450 W 40 - 450 VA 40 - 300 VA
40 - 500 W 40 - 500 VA 40 - 300 VA
10 m max
NOTE Installation of 2 dimmers in the same mounting box, the loads controlled by each dimmer must be reduced so that their total does not exceed the indicated values.Side views show the overall dimensions and the flush depth in mm Mountingboxes,framesandcoverplates,page189
31
SwitchesInfrared switches Infrared switchesAutomatic switch-on of equipments when persons or animals pass through the detection area of the IR motion sensor.
TECHNICAL CHARACTERISTICS Technical specificationssupplyvoltage: - 20181, 20184: 230 V~ 50-60 Hz - 20181.120: 120 V~ 50-60 Hz 20181:NOrelayoutput 20184: TRIAC output for incandescent lamps 60-300 W 20181.120:powerrelayoutput controllableloads: - resistive loads : 6 A (20181), 1,3 A (20184) - halogena and incandescent lamps : 1000 W (20181), 60-300 W (20184), 500 W (20181.120) - ferromagnetic transformers : 11000 VA (20181), 500 VA (20181.120) - electronic transformers : 700 VA (20181), 350 VA (20181.120) - fluorescent or compact fluorescent lamps: 60 W (20181), 30 A W (20181.120) 1,2 B - motors : 1,8 A cos 0,6 (20181 and 20181.120) C D 0 notsuitablefordirectcontroloffluorescentlamps m 0 1,5 8 10 front-mounted twilight sensor positioned under the Fresnel lens, +6 A = 3 rayswith trigger threshold adjustable from approximately 5 lx detection B = 6 rays +0 to rays -20 daylight using the front-mounted trimmer. C=5 D = 3 rays delay adjustable from 15 s to approximately 10 min, time -30 adjustable from the front-mounted trimmer. pyroelectric sensor and Fresnel lens with volumetric coverage operatingtemperature:0-+40CA B CB
Installationindoorinstallation flushmounting:1,1-1,2mabovefloorlevel possibility of mounting with 20635 orientable support, flush mounting with 20637 or surface mounting with 16831 possibilityofconnectinginparalleladditionalinfraredswitches to control one or more lamps possibilityofbypassingorinterruptingtheoutputcircuitwith normal electromechanical switches.
Conformity to Standards (20181 and 20184)LV Directive EMCDirective EN 60669-2-1 Standard
Detection rangeA
A C
B
C
C B
A B
C B Angle of detection - 112 horizontally - 36 min. vertically - 17 zones in 4 levels Detection:10mmax(typically8m)
1,2 0 m 0D
B
C
1,5
8 detection
10
8m D 1,5 m D D 112
A = 3 rays +6 B = 6 rays +0 C = 5 rays -20 D = 3 rays -30
20181 - Front viewA B CB
RegulationsB A B
A C
C
C B
C B Angle of detection - 112 horizontally - 36 min. vertically Timer adjustment - 17 zones in 4 levels Detection:10mmax(typically8m)
Fresnel lens
8m
Twilight sensor threshold adjustmentD D D 1,5 m 112
Only in the dark
Crepuscular
Always on
~ 15 s
~ 5 min
~ 10 min
20181 - Wiring diagramsL N L N
20184 - Wiring diagramL N
20181N L 1
20181N L 1
20181N L 1
20181N L 1
20184 20416L 1
32
Infrared switchesInfrared switch20181 .B *20181.120 20184 .B .B .N .N .N Automatic lighting switch with IR motion sensor, adjustable dusk/dawn sensor threshold and time delay cycle, NO 6 A 230 V~ relay output, supply voltage 230 V~ 50-60 Hz Automatic lighting switch with IR motion sensor, adjustable dusk/dawn sensor threshold and time delay cycle, NO 6 A 120 V~ relay output, supply voltage 120 V~ 50-60 Hz Automatic lighting switch with IR motion sensor, supply voltage 230 V~ 50-60 Hz for 60-300 W incandescent lamps, adjustable dusk/dawn sensor threshold and time delay cycle54,2 37 22,3
20181 grey
20181.B white
20181.N Next
20181.120 grey
20181.120.B white
20181.120.N Next
54,2 37 22,3
20184 grey 20635 20637 16831
20184.B white
20184.N Next
Orientable support.B .B .01 .N .N .N
1-module orientable support Adaptor for orientable support flush mounting - 2 modules. Not suitable for installation in Isoset IP44 and IP55 enclosures Frame for 20635 orientable support surface mounting4685,6 39
36,5
114
20637 grey
20637.B white
20637.N Next14,5
16831 grey
16831.01 white
16831.N Next
20635 - Flush mounting with 20637
20635 - Surface mounting with 16831
2018020180
1683120637
2063520635
Side views show the overall dimensions and the flush depth in mm Mounting boxes, frames and cover plates, page 189
* Only for Countries not members of the EU
33
79,5
20635 grey
20635.B white
20635.N Next
4944,8
49
SwitchesSpecial switches Set/Reset switch ScopeIt makes possible to develop a calling system for hospital (hospitals, rest homes, clinics) or industrial environments (factories, noisy laboratories), combined with remote optical and acoustic signalling functions to satisfy needs for assistance, intervention, emergency, etc.
TECHNICAL CHARACTERISTICS Technical specificationssupplyvoltage:12-24Vd.c./12V~ 10% 50-60 Hz absorption: approximately 100 mA with active RL1 and RL2 alarm outputs frontswitch:SETpushbutton two-colorLED: -green:devicesuppliedandnoactivatedalarm -flashingred:alarmactivated input: -normallyclosedconnectedtopositive(+)terminalforSET function -normallyclosedconnectedtopositive(+)terminalforRESET function RL1 alarm output: NO 5 A 250 V~ relay output with double insulation with respect to power supply and push buttons RL2 alarm output: NO 5 A 250 V~ relay output with double insulation with respect to power supply and push buttons controllableloads: - resistive loads :5A - incandescent lamps :500W - magnetic core transformers for very low voltage incandescent lamps (e.g. halogen lamps) :500W
Conformity to StandardsLV Directive EMC Directive EN 60669-2-1 Standard
20183 - Wiring diagramL N
12-24 V d.c. 12 V~
++ -
250 V~ max
RESET SET
S
R
Connections in the hospital setting
CONTROl PANEL - NURSES ROOMOther rooms
Red call indicator units
1
2
3
4 230 V~
5 other room
6
7
8 other room
230 V~ Floor bell
other roomsL N
ROOM 6
Nurse presence green indicator unit
Red call indicator unit
ROOM 7
Nurse presence green indicator unit
Red call indicator unit
230 V~R 12V ~ +
RESET 230 V~ SET
S
RESET SET
S
12 V~ SELV
34
R
12V ~ +
2P 1-way switch indicating nurse presence
230 V~
2P 1-way switch indicating nurse presence
Special switchesSet/Reset switch20183
.B
.N
SET/RESETswitchforemergencycallsystem,visibleindarkness,2NO5A250V~relayoutputsforacousticand optical signals, supply voltage 12 V~ 50-60 Hz or 12-24 V d.c. (SELV) - 2 modules.S ETwithbuilt-inpushbuttonorfromperipheralNCpushbuttonsconnectedinseries.RESETfromperipheralNCpushbuttonsconnectedinseries49,7 38,5 44,8
20183 grey
20183.B white
20183.N Next
20183 - Example of use
1ALARM ALARM ALARM
C C A A
B B D DVIMAR
Alarm
VIMAR
VIMAR
VIMAR
Alarm AlarmVIMAR
VIMAR
1) Thepatientmakesacallbypressingthe push button 20010.0+20022 (ALARM customized), or by pressing 20053, cordoperatedpushbutton,therebyactivating: A.SET/RESET20183switchand its corresponding indicator unit in the patients room camera del paziente B. bell in the corridor C. lights 20387.R red indicator unit in the corridor D.lights 20386.R red indicator unit in the nurses station and 20373 bell corresponding to thje callers number
Note: the bell B is silenced after 3 seconds; the indicator unit lights A - C - D begins flashing to confirm the call
2Alarm Reset Alarm Alarm Reset Reset
C C A A D DVIMAR
VIMAR
VIMAR
VIMAR
Alarm
VIMAR
VIMAR
VIMAR
Alarm AlarmVIMAR
VIMAR
2) Thenursewhoentersthepatients room resets the push button 20010(with RESETcustomization),stopping the flashing of devices A - C - D
3
F
Alarm
Reset
Alarm Alarm
Reset Reset
E EVIMAR
VIMAR
Alarm
VIMAR
VIMAR
VIMAR
F FAlarm AlarmVIMAR VIMAR
VIMAR
VIMAR
3) f the nurse needs to stay in the room he/she may notify thereof by activating 20015 2P 1-way switch (customized )thereby: E. light 20387.V green indicator unit in the corridor F. enables operation of the 20378 buzzer in case of call from another room
Side views show the overall dimensions and the flush depth in mm Mounting boxes, frames and cover plates, page 189
35
SwitchesSpecial switches Switch with current sensor ScopeIt activates and deactivates automatically mulitple SLAVE sockets by controlling the absorption of the primary load connected totheMASTERsocket.Suitableforbusinessuse(offices,laboratories, engineering firms, etc.) as well as residential (computers, DIY workbenches, etc.)
TECHNICAL CHARACTERISTICS Conformity to StandardsLV Directive EMC Directive EN 60669-2-1 Standard
20188 - Wiring diagram
Technical specificationssupplyvoltage:230V~50-60Hz output:1PNO16A230V~ 2-colourLED: - green = mains presence - red = closed circuit controllableloads: - resistive loads :16A - incandescent lamps :1000W -enegysavingfluorescentlamps:60W - magnetic core transformers for extra low voltage incandescent lamps (for example, halogen lamps) :1000W - motors :3Acos 0,6 absorption:approximately20mAwithrelayengaged
L N
MASTER
SLAVE
Schema elettrico per comando Master-Slave
20188 - Example of use
The computer connected to the MASTER socket absorbs energy because it has been activated (ON) and thus the switch with current sensor 20188 automatically closes the downstream circuit, activating the loads (printer and scanner) connected to the SLAVE sockets.
OFF
The computer connected to the MASTER socket does not absorb energy (OFF), and thus the switch with current sensor 20188 opens the downstream circuit, deactivating the loads (printer and scanner) connected to the SLAVE sockets.
36
Special switchesSwitch with current sensor20188 .B .N Switch with current threshold sensor preset to 15 W to control SLAVE sockets, 1P NO 16 A 230 V~ output, supply voltage 230 V~ 50-60 Hz - 2 modules46,5 37 44,8
20188 grey
20188.B white
20188.N Next
Side views show the overall dimensions and the flush depth in mm Mounting boxes, frames and cover plates, page 189
37
SwitchesSocket outlets ScopeSupply of electrical household appliances, lighting fittings, etc.
TECHNICAL CHARACTERISTICS
Italian standard socket outlets 250 V~
Technical specificationssupplyvoltage:250V~ ratedcurrent:10Aor16A socketoutletwithincreasedprotectionandshutteredsocketcontacts insulationresistancetestedwith500Vd.c.:>5M dielectricstrength:2000V~
breakingcapacity:50operations(plugandwithdrawnofthe plug) to 1,25 In 275 V~ cos 0,6 electricallife:>5.000operations(plugandwithdrawnofthe plug) with rated current and voltage to cos 0,6 resilientwrapsocket-contacts priorityofconnectiononearthingsocket-contacts
Conformity to StandardCEI 23-50 (IEC 60884-1) Standard
Plugs and socket outlets - matching possibilities
Plug and socket outlet matching standards
19
19
26
26
Standard plugs
VIMAR productsS10VIMAR
19 P11 20201 P17 20202 P17/11 20203 P30 20209
19 26 20210
01020 - 01020.B 01040 - 01040.B 01045 - 01045.B
-------
01020 - 01020.B 01040 - 01040.B 01045 - 01045.B
01020 - 01020.B --01045 - 01045.B
01020 - 01020.B --01045 - 01045.B
MILLE
4
19
SUPERNOVA
4
S10
2P 10 A4
2P 2,5 A
4
18
Eurospina
S11
MILLE
VIMAR
4 4
19
SUPERNOVA
S11 SPA11 S11
4
2P+E 10 A
5
2P 16 A S17
5
26
S16
MILLE
5
5
VIMAR
26
SUPERNOVA
S17 SPA17 S17 German standard German + French standards German + French standards
5
2P+E 16 A 4,8
SUPERNOVA
19
4,8 2P+E 16 A
38
VIMAR
S17
VIMAR
SPA17
VIMAR
S11
VIMAR
SPA11
VIMAR
S10
VIMAR
00200 - 00200.B
---
00200 - 00200.B
00200 - 00200.B
00200 - 00200.B
---
01021 - 01021.B 01041 - 01041.B 01046 - 01046.B 00201 - 00201.B 00206 - 00206.B 00211 - 00211.B
-------------
01021 - 01021.B 01041 - 01041.B 01046 - 01046.B 00201 - 00201.B 00206 - 00206.B 00211 - 00211.B
01021 - 01021.B --01046 - 01046.B 00201 - 00201.B --00211 - 00211.B
01021 - 01021.B --01046 - 01046.B 00201 - 00201.B --00211 - 00211.B
---
---
-------------------
01026 - 01026.B 01043 - 01043.B 01048 - 01048.B 00202 - 00202.B 00207 - 00207.B 00212 - 00212.B -------
01026 - 01026.B 01043 - 01043.B 01048 - 01048.B 00202 - 00202.B 00207 - 00207.B 00212 - 00212.B -------
------------00230 - 00230.B 00231 - 00231.B 00241 - 00241.B
01026 - 01026.B --01048 - 01048.B 00202 - 00202.B --00212 - 00212.B 00230 - 00230.B 00231 - 00231.B 00241 - 00241.B
Socket outlets20201 20202 20203
Italian standard socket outlet 250 V~.B .B .B .N .N .N
2P+E 10 A SICURY socket outlet, Italian standard P11 2P+E 16 A SICURY socket outlet, Italian standard P17 2P+E 16 A SICURY Bpresa socket outlet, Italian standard P17/1134,5 25 22,3
20201 grey
20201.B white
20201.N Next
20202 grey
20202.B white
20202.N Next
34,5 25 22,3
20203 grey
20203.B white
20203.N Next
20209 20210
Italian standard socket outlet 250 V~.B .B .N .N
2P+E 16 A SICURY socket outlet, Italian standard P30 (lateral and central earth contacts) - 2 modules 2P+E 16 A SICURY socket outlet, universal, for 2P 2,5 A Europlugs, 2P and 2P+E 10 A and 16 A Italian standard plugs, 2P+E 16 A 250 V~ German standard plugs - 2 modules. No earth connection is realized with French standard plug38,9 29,4 44,8
20209 grey
20209.B white
20209.N Next
35,5 26 44,8
20210 grey
20210.B white
20210.N Next
Side views show the overall dimensions and the flush depth in mm Mounting boxes, frames and cover plates, page 189
39
49
49
SwitchesSocket outlets TECHNICAL CHARACTERISTICS Socket outlet 250 V~ for dedicated supply lines ScopeSuitable for use in the service industry, like offices, clinics, doctors consulting rooms, laboratories, and wherever there are lines dedicated to the supply of equipments which need to continue working even in the event of a power failure (lines protected by generating sets, lines supplied by no-break generating sets, etc.). Thesocketoutletsfordedicatedsupplylinesaredifferently coloured (red, orange or green), so that the dedicated supply lines, with a nominal voltage of 230 V~, can be visually identified.
Currently, in Europe, there are no standards in force concerning the corrispondence between socket outlet coulour and type of supply. Differentiationis,however,madebyfieldofapplication: Orangecolour: power supply line protected by mains/generating set via an isolating transformer Redcolour: uninterrupted power supply using UPS (Uninterruptable Power Supply) via an isolating transformer. Greencolour: safety supply line from mains/generating set
Conformity to StandardsCEI 23-50 (IEC 60884-1) Standard
Example of use20209.V and 20209.R 20209.A
20209.A and 20209.R
20210.R
40
Socket outletsSocket outlet 250 V~ for dedicated supply lines20203.R 2P+E 16 A SICURY Bpresa socket outlet, Italian standard P17/11, red34,5 25 22,3
20203.R
Socket outlet 250 V~ for dedicated supply lines20209.A 20209.R 20209.V
2P+E 16 A SICURY socket outlet, Italian standard P30 (lateral and central earth contacts), orange - 2 modules As above, red As above, green38,9 29,4 44,8 38,9 29,4 44,8
20209.A
49
20209.R38,9 29,4 44,8
20209.V
Socket outlet 250 V~ for dedicated supply lines20210.R
2P+E 16 A SICURY socket outlet, universal, for 2P 2,5 A Europlugs, 2P and 2P+E 10 A and 16 A Italian standard plugs, 2P+E 16 A 250 V~ German standard plugs, red - 2 modules. No earth connection is realized with French standard plug35,5 26 44,8
20210.R
Side views show the overall dimensions and the flush depth in mm Mounting boxes, frames and cover plates, page 189
41
49
SwitchesSocket outlets ScopeInterlocked socket outlets with circuit breaker (CB) Equipments suitable to be installed in terminal points for the two-pole protection of the load supplied by the socket outlet, especially electrical household appliances, against short-circuit and overload. Interlocked socket outlets with residual current breaker with overcurrent protection (RCBO) Equipments suitable to be installed in terminal points for the protection of the load supplied by the socket outlet, especially electrical household appliances, against short-circuit and overload, and for the protection of the user against electrocution. Theresidualcurrentoperationwithsensitivity10mAcorrectly operates even in case of non-sinusoidal fault currents (alternate currents with unidirectional pulsating currents). Theyareparticularlysuitablefortheprotectionof: appliancesattheendofthelineinlocationswithhighriskof electrocution (bathrooms, shower-baths, etc.) socket outlets for the supply of class I appliances with electronic circuits socket outlets for the supply of portable appliances in residential and similar applications (electric irons, electrical tools, etc.)
TECHNICAL CHARACTERISTICS Conformity to StandardsSocketoutlet:CEI23-50(IEC60884-1)Standard Circuitbreaker:LVDirective, EN 60898 Standard Residualcurrentbreakerwithovercurrentprotection: LV Directive, EMC Directive, EN 61009-1 Standard
Technical specificationsTheinterlockedcircuitbreakerortheinterlockedresidual current breaker with overcurrent protection (CB or RCBO) associated to the socket outlet supply the socket-contacts only when the plug is fully inserted and automatically stop the supply before the complete withdrawn of the plug. Theplugisthusalwaysinsertedandwithdrawnwithoutarching. Theswitchlever,whentheplugisnotinsertedintothesocketoutlet, is idle and cannot close the switch. supply voltage:120-230V~-15%+10%50-60Hz residualcurrent(sensitivity):In 10 mA operation depending on the mains voltage (standard EN 61009-1, 4.1.2 ): to be connected after a master RCBO interlockingdevice,VIMARpatent Ctypemagneto-thermicaction(seecurrent-timetripping diagram) two-poledisconnectionwith1protectedpole breakingcapacity:3000A ratedcurrentaccordingtothesocketoutletstandard A type equipment for alternating and unidirectional pulsating fault currents green light frontal LED: when illuminated, it indicates normal operations, i.e. mains voltage present and contacts closed
Interlocked socket outlet wiring diagramL NL N
20271 - 20273
20276
L N
L N
20281 - 20283
20286
Current-time tripping diagram300 200 100 80 60 40 20
Thermaltripping area with cold start
MINUTES SECONDS
10 8 6 4 2 1 40 20 10 8 6 4 2 1 0,8 0,6 0,4 0,2 0,1 0,08 0,06 0,04 0,02 0,01
Electromagnetic tripping area
1 1.1 1.2
1.5
2
2.5
3
4
5
6
7
8
9
10 11 12
MULTIPLES OF RATED CURRENT In
42
Socket outletsInterlocked socket outlet with CB20271 20273 .B .N .B .N 2P+E 10 A 250 V~ SICURY socket outlet, Italian standard P11, intelocked with 1P+N C 10 circuit breaker, supply voltage 120-230 V~ 50-60 Hz, breaking capacity 3000 A - 2 modules 2P+E 16 A 250 V~ SICURY Bpresa socket outlet, Italian standard P17/11, intelocked with 1P+N C 16 circuit breaker, supply voltage 120-230 V~ 50-60 Hz, breaking capacity 3000 A - 2 modules56,35 39,6
44,
L N
20271 grey
20271.B white
20271.N Next56,35 39,6
44,
20273 grey
20273.B white
20273.N Next
Interlocked socket outlet with CB20276 .B .N
2P+E 16 A 250 V~ SICURY socket outlet, Italian standard P30 (lateral and central earth contacts), intelocked with 1P+N C 16 circuit breaker, supply voltage 120-230 V~ 50-60 Hz, breaking capacity 3000 A - 3 modules
56,35
L N
39,7
20276 grey
20276.B white
20276.N Next
Interlocked socket outlet with RCBO20281 .B .N 20283 .B .N
2P+E 10 A 250 V~ SICURY socket outlet, Italian standard P11, intelocked with 1P+N C 10 circuit breaker with overcurrent protection, supply voltage 120-230 V~ 50-60 Hz, In 10 mA, breaking capacity 3000 A - 3 modules 2P+E 16 A 250 V~ SICURY Bpresa socket outlet, Italian standard P17/11, intelocked with 1P+N C 16 circuit breaker with overcurrent protection, supply voltage 120-230 V~ 50-60 Hz, In 10 mA, breaking capacity 3000 A - 3 modules56,35 39,6
67,3
TEST
L N
20281 grey
20281.B white
20281.N Next
56,35 39,6
67
20283 greySide views show the overall dimensions and the flush depth in mm Mounting boxes, frames and cover plates, page 189
20283.B white
20283.N Next
43
SwitchesSocket outlets Interlocked socket outletsTechnicalspecifications:seepage42
TECHNICAL CHARACTERISTICS
VIMAR
VIMAR
VIMAR
1. Equipment at rest No voltage reaches the socket-contacts of the socket outlet; the switch leverisidle:thereisnopossibilityof contact, even intentional, with live parts.
Shaver supply unitTheshaversupplyunitisprovidedwithabuilt-inisolating transformer rated 20 VA, which is protected against overload and supplied through the push button directly actuated on insertion of the plug. Thesecondarycircuit(onwhichthesocketcontactsterminate) is separated from the primary power supply circuit by a double insulation :thismakessuperflousanyadditionalsafety measure on the socket outlets (shutters).
supplyvoltage:230V~50-60Hz outputvoltage: - 230 V~ for 2P 2,5 A Europlugs - 120 V~ for 2P 15 A 125 V~ American standard plugs with nonpolarized flat blades maxload:20VA overloadprotectionwithautomaticreset Theshaversupplyunitisprotectedagainstoverloadingwith a thermal cut-off device without automatically switching back on. After the safety device trips the supply unit pins are not powered. To close the circuit again you need to unplug the device that caused the overload and wait for a few minutes for the transformer to cool down.
12,7
Technical specifications
for 2P 2,5 A Europlugs
44
19
VIMAR
2. Plug insertion and withdrawn Theswitchcanbeclosedtosupplythesocketoutlet,only when the plug is fully inserted. As soon as the plug starts being withdrawn, the switch opens: plug insertion and withdrawn take always place in absence of voltage on the socket-contacts of the socket outlet.
3. Switch tripping The switch (CB) trips in case of short-circuit or overload; if provided with residual current operated function (RCBO), it also trips in case of direct or indirect contacts.
Conformity to StandardsLV Directive EN 61558-2-5 Standard
Socket-contact standardsfor 2P 15 A 125 V~ American standard plugs with non-polarized at blades
Socket outletsInterlocked socket outlet with RCBO20286 .B .N 2P+E 16 A 250 V~ SICURY socket outlet, Italian standard P30 (lateral and central earth contacts), intelocked with 1P+N C 16 circuit breaker with overcurrent protection, supply voltage 120-230 V~ 50-60 Hz, In 10 mA, breaking capacity 3000 A - 4 modules
TEST
L N
56,35 39,7
20286 grey
20286.B white
20286.N Next
Shaver supply unit20290 .B .N
Shaver supply unit with 20 VA isolating transformer, 230 V~50-60 Hz input voltage, 120 V~ output voltage for 2P 15 A 125 V~ American standard plugs with non-polarized flat blades and 230 V~ output voltage for 2P 2,5 A Europlugs - 3 modules. Not suitable for installation in Isoset IP44 and IP55 enclosures
51,5 42
20290 grey
20290.B white
20290.N Next
Side views show the overall dimensions and the flush depth in mm Mounting boxes, frames and cover plates, page 189
45
SwitchesSocket outlets TECHNICAL CHARACTERISTICSOther standard socket outlets
20208 Italian standard plug S10 2P 2,5 A Europlug 2P+E 16 A 250 V~ German standard plug 2P+E 16 A 250 V~ German/French standard plug 2P+E 16 A 250 V~ French standard plug 2P 15 A 125 V~ American standard plug 2P+E 15 A 125 V~ American standard plugStandard plug matching the socket outlet Standard plug matching the socket outlet without continuity of the earth connection Socket outlet matching the same standard plug, only
20212
20234
20242
20243
20220
20250
Conformity to StandardsGermanstandardsocketoutlet:DINVDE0620-1Standard Frenchstandardsocketoutlet:NFC61-314Standard
VIMAR plugs - other standards00230:2P+E16A250V~Germanstandard 00231:2P+E16A250V~German/Frenchstandards 00232:2P+E16A250V~Frenchstandard 00241:2P+E16A250V~German/Frenchstandards
46
Socket outlets20208 20212
Other standard socket outlet.B .B .N .N
2P+E 16 A 250 V~ SICURY socket outlet, German standard - 2 modules 2P+E 16 A 250 V~ SICURY socket outlet, French standard - 2 modules38,9 29,4 44,8
20208 grey
20208.B white
20208.N Next
35,9 26,4 44,8
20212 grey
20212.B white
20212.N Next
20220 *20234 *20250
Other standard socket outlet.B .B .N .N
.B
.N
2P+E 13 A 250 V~ SICURY socket outlet, English standard - 2 modules 2P 16 A 250 V~ SICURY socket outlet, Euro-American standard (parallel flat pins and 4,8 mm pins) 2P+E 10 A 250 V~ SICURY socket outlet, Argentinian standard
35,9 24,4 44,8
38 28,5
20220 grey22,3
20220.B white
20220.N Next
37 27,5 22,3
20234 grey
20234.B white
20234.N Next
20250 grey
49
20250.B white
20250.N Next
*20242 *20243
Other standard socket outlet.B .B .N .N
2P+E 15 A 127 V~ SICURY socket outlet, American and Saudi Arabian standards Two2P+E15A127V~SICURYsocketoutlets,AmericanandSaudiArabianstandards-3modules36,9 27,4 22,3
20242 grey
20242.B white
20242.N Next
35,5 26
6
20243 greySide views show the overall dimensions and the flush depth in mm Mounting boxes, frames and cover plates, page 189
20243.B white* Only for Countries not members of the EU
20243.N Next
47
SwitchesSignal reception socket outlets 20320 - 20321 Phone jacks Technical specifications- screw terminal connection
TECHNICALCHARACTERISTICS
Phone jack wiring diagramL2 TX L1 TS 2 TX L2 L1 TS T
20320 - Wiring diagramL1 L220320 L1 TS L2 TX 20320 L1 TS L2 TX 20320 L1 TS L2 TX
20320 RJ11 6-position 4-conductor
20321 RJ12 6-position 6-conductor
NOTE L1-TSlineisinterrupted,whenthephonejacksarewiredasinthediagramabove:ifthe phone plug is withdrawn from a socket connector, all phone jacks connected after it in the installation would be disconnected. Toovercomethisinconvenience,insertaplugwithL1-TSjumper.
Example of use
VIMAR
48
Signal reception socket outletsSocket outlet for special purpose20331 20333 20334 .B .B .B .N .N .N Polarized 2P 6 A 24 V (SELV) socket outlet for 01616 and 01617 plugs (1 3 mm pin and 1 4 mm pin, 12,4 mm distance between centres). ForHi-Fiinstallations,HFTRreception,etc. 5P DIN 41524 (60130-9 IEC-04) socket connector, soldering terminal point. For phonic circuits, Hi-Fi and similar installations 2P socket outlet with 60130-9 IEC-07 point-line connector, soldering terminal points. For phonic circuits, Hi-Fi and similarinstallations34,5 25 22,3
20331 grey
20331.B white
20331.N Next21 11 22,3
20333 grey
20333.B white
20333.N Next20,5 11 22,3
20334 grey
20334.B white
20334.N Next
20320 20321 20327
Phone jack.B .B .B
.N .N .N
RJ11 phone jack, 6-position, 4-conductor (6/4), screw terminals RJ12 phone jack, 6-position, 6-conductor (6/6), screw terminals 8-conductor French standard phone jack - 2 modules43,1 33,6 22,3
20320 grey
20320.B white
20320.N Next43,1 33,6 22,3
20321 grey
20321.B white
20321.N Next31,5 22 44,8
20327 greySide views show the overall dimensions and the flush depth in mm Mounting boxes, frames and cover plates, page 189
20327.B white
20327.N Next
49
49
SwitchesSignal reception socket outlets EDP socket connectors ScopeDevices designed to realize information or telephone networks.
TECHNICAL CHARACTERISTICS
Cabling code20339.4T-568A
7
8
A 2 1 B
6
3
T-568B
20338.8 - Colour coded wiring
20338.8 - Assembly
20338.9
T-568A
7 8
4
5
A B
T-568B
50
5
4
B
2 1 B 6 3 A A
CA T.5 e
2 1 6 3
A B
Signal reception socket outletsEDP socket connector20339.4 .B .N .N .N 20339.5 20339.6 .B .B RJ45outletwithNetsafeCat.5econnector,unshielded,T568A/Buniversalwiring,8-contact,110-type insulation-piercing terminals RJ45outletwithNetsafeCat.5econnector,shielded,T568A/Buniversalwiring,8-contact,110-typeinsulation-piercing terminals RJ45outletwithNetsafeCat.6connector,unshielded,T568A/Buniversalwiring,8-contact,110-typeinsulation-piercing terminals33,8 24 22,3
20339.4 grey
20339.4.B white
20339.4.N Next
45,65 36,15 22,3
20339.5 grey
20339.5.B white
20339.5.N Next33,8 24 22,3
20339.6 grey
20339.6.B white
20339.6.N Next
EDP socket connector20338.8 .B .N 20338.9 .B .N
RJ45outletwithNetsafeconnector,Cat.5e,unshielded,T568A/Buniversalwiring,8-contact,insulation-piercing terminals without tool use RJ45outletwithNetsafeconnector,Cat.5e,unshielded,T568A/Buniversalwiring,8-contact,insulation-piercing terminals without tool use33,1 23,6
22,3
20338.8 grey
20338.8.B white
20338.8.N Next35,9 26,4 22,3
20338.9 grey
20338.9.B white
20338.9.N Next
Side views show the overall dimensions and the flush depth in mm Mounting boxes, frames and cover plates, page 189
51
49
49
49
SwitchesSignal reception socket outlets EDP socket connectors ScopeDevices designed to realize information or telephone networks.
TECHNICAL CHARACTERISTICS
20340.1 and 20340.2 cabling code
2
R F
B A B A
RB A B A
1F R FB A B A
F
FR FB A B A
T568A
T568B
2
1
R F
B A B A
R F
B A B A
20338.1 cabling codeT568A 1:White/Green 2:Green 3:White/Orange 4:Blue 5:White/Blue 6:Arancio 7:White/Brown 8:Brown T568B 1:White/Orange 2:Arancio 3:White/Green 4:Blue 5:White/Blue 6:Green 7:White/Brown 8:Brown6 3 8 7
4
5 2
1
1,6 mm max
52
Signal reception socket outletsEDP socket connector20340.1 .B .N .N 20340.2 .B RJ45outletwithPanduit(MINI-COM)connector,Cat.5e,unshielded,T568A/Buniversalwiring,8-contacts,insulation- piercing terminals RJ45outletwithPanduit(MINI-COM)connector,Cat.5e,shielded,T568A/Buniversalwiring,8-contacts,insulation- piercing terminals
38,05 28,55 22,3
20340.1 grey
20340.1.B white
20340.1.N Next38,55 29,05 22,3
20340.2 grey
20340.2.B white
20340.2.N Next
EDP socket connector20338.1 .B .N .N .N 20338.3 20338.4 .B .B
RJ45outletwithAT&T/LucentTechnologiesAvaya(MPS100E)connector,Cat.5e,unshielded,T568A/Buniversal wiring, 8-contact, insulation-piercing terminals RJ45outletwithAMP/TycoToollessJackconnector,Cat.5e,unshielded,T568A/Buniversalwiring,8-contacts, insulation-piercing terminals RJ45outletwithAMP/TycoToollessJackconnector,Cat.5e,shielded,T568A/Buniversalwiring,8-contacts, insulation-piercing terminals31,8 22,3
22,3
20338.1 grey
20338.1.B white
20338.1.N Next32,2 22,7 22,3
20338.3 grey
20338.3.B white
20338.3.N Next41,6 32,1 22,3
49
20338.4 greySide views show the overall dimensions and the flush depth in mm Mounting boxes, frames and cover plates, page 189
20338.4.B white
20338.4.N Next
53
49
SwitchesSignal reception socket outlets 20361 - Socket connector TECHNICAL CHARACTERISTICS
CH13
BNC
54
Signal reception socket outlets20338.C 20340.C 20341.C
Adaptor for EDP connectors.B .B .B .N .N .N
AdaptorforRJ45Cat.5connectors: AMP/Tyco(Jack110series,ToollessJack,JackMTRJ) LucentTechnologies/Avaya/SystimaxMPS100,MGS200,MGS300,MGS400andMGS500 Adaptor for MINI-COM Panduit modules Adaptor for RJ45 Cat. 5e and 6 Slim of Infra+ and Merlin Gerin connectors
20,5 11 22,3
20338.C grey
20338.C.B white
20338.C.N Next20,5 11 22,3
20340.C grey
20340.C.B white
20340.C.N Next20,5 11 22,3
20341.C grey
20341.C.B white
20341.C.N Next
EDP socket connector20361 20365 20367 .B .B .B .N .N .N
Bayonettypecoaxialsocketconnector,jackBNC,forRG58,RG59/62,RX93cablessoldering 9-pin socket connector, SUB D, soldering - 2 modules 25-pin socket connector, SUB D, soldering - 3 modules31,7 11 22,3
20361 grey
20361.B white
20361.N Next20,5 11
6
20365 grey
20365.B white
20365.N Next20,5 11
6
20367 greySide views show the overall dimensions and the flush depth in mm Mounting boxes, frames and cover plates, page 189
20367.B white
20367.N Next
55
SwitchesTV-RD-SAT 5-2400 MHz socket outlets Coaxial TV-RD-SAT socket outlets Scopeconnect user equipments to systems for the distribution of analogic or digital sound and video signals, from terrestrial, satellite or cable link, in the 5-2400 MHz frequency band permittheconnectionofasingledevice(e.g.TVorSATreceiver) can be used for satellite Internet applications and, thanks to the 5-40 MHz return channel, also for interactive functions (hotelcommunicationsandcableTV) a choice of single connection sockets allows the passage of d.c. current and control signals, and of through-line sockets with three different attenuation ratings, ensures optimal utilisation on any type of individual or central distribution configuration (see table overleaf).
TECHNICAL CHARACTERISTICS
Some examples of the supported system topologies Multiple socket outlets in cascade Multiple parallel connected socket outlets Combined cascade/parallel connected Multi-switch for satellite signal distribution Multi-switch for combined terrestrial and satellite signal distribution Combined cascade/parallel with IF-IF conversion unit for singlecable distribution of combined terrestrial and satellite signals Combined cascade/parallel with modular unit for feeding terrestrial and satellite programs in the 40-862 MHz band (terrestrial)
Technical specificationsfrequencyrange:5-2400MHz output:IEC60169-2maleconnector returnchannelin5-40MHzband shieldingefficiency:Aclass cabledimensions: - internal wire 3 mm max -externalinsulatingsheath:5-7mm
The range1singleconnectionsocketwhichallowsthepassageofd.c. current and control signals (24 V 500 mA max) 3through-linesocketswith: - connection attenuation 10 dB - connection attenuation 15 dB - connection attenuation 20 dB The through-line sockets can become end-of-line sockets if closed with the special terminal resistor 16330. They allow d.c. current and control signals (24 V 500 mA max) to pass through the line, but not to the user port (IEC 60169-2 male connector).
Conformity to StandardsEN 50083-1, EN 50083-4 Standards EMC Directive EN 50083-2 Standard
AttenuationsSocket type Type of attenuations 5-40 Single connection 1 dB Through-line 10 dB Throughpass attenuation (dB) Connection attenuation (dB) Through-line 15 dB Throughpass attenuation (dB) Connection attenuation (dB) Through-line 20 dB Throughpass attenuation (dB) 0,8 0,5 0,7 0,8 1 1,3 0,8 20 0,8 20 0,8 20 0,9 20 1,1 0 1,4 20 1,5 15 1,2 15 1,2 15 1,3 15 1,7 15 2 15 Connection attenuation (dB) Connection attenuation (dB) 0,1 11,5 40-470 0,2 10 Frequencies (MHz) 470-862 0,3 10 862-950 0,3 10 950-1750 0,5 10 1750-2400 0,7 11,5
How to connectProgrammes - Applications TerrestrialTVRadio receiver
Programmes - Applications Terrestrial radio
IEC 60169-2 male
IEC 60169-2 male
Programmes - Applications CableTV(CATV) Interactive hotel communicationsIEC 60169-2 male STB (SetTop Box) SCARTcableconnection IEC 60169-2 male SAT
Programmes - Applications SatelliteTVandradio
Coaxial cable connection
56
TV-RD-SAT 5-2400 MHz socket outletsCoaxial TV-RD-SAT 5-2400 MHz socket outlet20300.01 .B .N .N .N .N 20300.10 20300.15 20300.20 .B .B .B CoaxialTV-RD-SAT5-2400MHzsocketoutlet,singleconnection,withIEC60169-2maleconnector,connection attenuation 1 dB. Allows the passage of d.c. current and control signals (24 V 500 mA max) CoaxialTV-RD-SAT5-2400MHzsocketoutlet,through-line,withIEC60169-2maleconnector,connectionattenuation10dB As above, connection attenuation 15 dB As above, connection attenuation 20 dB36,3
Single-connectionAd:1 dB 24 V 500 mA max
26,8
22,3
IEC 60169-2 male
20300.01 greyThrough-lineAd: 10 dB 15 dB 20 dB
20300.01.B white
20300.01.N Next36,3 26,8 22,3
20300.10 20300.15 20300.20 grey
20300.10.B 20300.15.B 20300.20.B white
20300.10.N 20300.15.N 20300.20.N Next
InstallationCable drop from below Cable drop from above
15
2 8
15
2 8
Cable insertion
Cord-grip closing
Side views show the overall dimensions and the flush depth in mm 16330 terminal resistor, page 59 - Mounting boxes, frames and cover plates, page 224
57
49
IEC 60169-2 male
49
0 12
0 12
20
20 0
0
SwitchesTV-RD-SAT 5-2400 MHz socket outlets connect user equipments to systems for the distribution of analogic or digital sound and video signals, via terrestrial, satellite or cable link, in the 5-2400 MHz frequency band permitsthesimultaneousconnectionoftwodevices(e.g.TV andSATreceiver,orTVandradio) can be used for satellite Internet applications and, thanks to the 5-40 MHz return channel, also for interactive functions (hotelcommunicationsandcableTV) the availability of single connection socket outlets allows the passage of d.c. current and control signals, and of throughline socket outlets with three different attenuation ratings and ensures optimal utilisation on any type of individual or central distribution configuration (see table overleaf).
TECHNICAL CHARACTERISTICS
Coaxial TV-RD-SAT socket outlets Scope
Some examples of the supported system topologies Multiple socket outlets in cascade Multiple parallel connected socket outlets Combined cascade/parallel Multi-switch for satellite signal distribution Multi-switch for combined terrestrial and satellite signal distribution Combined cascade/parallel with IF-IF conversion unit for singlecable distribution of combined terrestrial and satellite signals Combined cascade/parallel with modular unit for feeding terrestrial and satellite programs in the 40-862 MHz band (terrestrial)
1singleconnectionsocketoutletwhichallowsd.c.currentand control signals (24 V 500 mA max) to pass through the IEC 60169-2 female connector 3through-linesocketoutletswith: - connection attenuation 10 dB - connection attenuation 15 dB - connection attenuation 20 dB Thethrough-linesocketoutletscanbecomeend-of-linesocket outletsifclosedbythespecialterminalresistor16330.They do not allow d.c. current and control signals (24 V 500 mA max) to pass through the line or on the user output.
The range
2-output TV-RD-S AT: how to connectIEC 60169-2 male
Programmes - Applications TerrestrialTV Terrestrial radio CableTV(CATV) Interactivehotel communications
IEC 60169-2 female
Radio receiver STB (SetTop Box)
Programmes - Applications TerrestrialTV SatelliteTVandradioIEC 60169-2 male TVinput IEC 60169-2 female SATinput Coaxial cable connection SAT SCARTcableconnection
Technical specifications
frequencyrange:5-2400MHz outputs:IEC60169-2maleandIEC60169-2female connectors returnchannelinthe5-40MHzband shieldingefficiency:Aclass cabledimensions: - internal wire 3 mm max -externalinsulatingsheath:5-7mm
Conformity to StandardEN 50083-1, EN 50083-4 Standards EMC Directive EN 50083-2 Standard
AttenuationsSocket type Type of attenuation Connector 5-40 Connection attenuation (dB) Singe connection 5 dB Min. internal decoupling (dB)* Connection attenuation (dB) Through-line 10 dB Throughpass attenuation (dB) Min. internal decoupling (dB)* Connection attenuation (dB) Through-line 15 dB Throughpass attenuation (dB) Min. internal decoupling (dB)* Connection attenuation (dB) Through-line 20 dB Throughpass attenuation (dB) Min. internal decoupling (dB)* IEC 60169-2 male IEC 60169-2 female IEC 60169-2 male IEC 60169-2 female IEC 60169-2 male IEC 60169-2 female IEC 60169-2 male IEC 60169-2 female 8 5 20 11,5 3,8 20 14,5 2,2 20 20 2,2 20 40-470 5 5 20 10 3 20 15 2,2 20 20 1,3 26 Frequencies (MHz) 470-862 862-950 5 5 20 10 3 20 15 2,2 20 20 1,5 24 5,5 5,5 20 10 3 20 15 2,2 20 20 1,6 22 950-1750 6 5,5 20 10 3,4 20 15 2,4 20 20 2,5 20 1750-2400 7 6 20 11,5 3,4 20 15,5 3,2 20 21 3,2 23
* Internaldecoupling:isolationbetweenIEC60169-2maleandIEC60169-2female.
58
TV-RD-SAT 5-2400 MHz socket outlets - F-Type socket outletsCoaxial TV-RD-SAT 5-2400 MHz socket outlet20310.05 20310.10 20310.15 20310.20 .B .B .B .B .N .N .N .N CoaxialTV-RD-SAT5-2400MHzsocketoutlet,singleconnection,2IEC60169-2maleandfemaleoutputs, connection attenuation 5 dB - 2 modules. Allows the passage of d.c. current and control signals (24 V 500 mA max) through the female connector CoaxialTV-RD-SAT5-2400MHzsocketoutlet,through-line,2IEC60169-2maleandfemaleoutputs,connection attenuation 10 dB - 2 modules As above, connection attenuation 15 dB As above, connection attenuation 20 dB36 26,5 44,8
Single connection
Ad:5 dB 24 V 500 mA max
IEC 60169-2 female
IEC 60169-2 male
20310.05 grey
20310.05.B white
20310.05.N Next36 26,5 44,8
Through-lineAd:10 dB 15 dB 20 dB
IEC 60169-2 female
IEC 60169-2 male
20310.10 20310.15 20310.20 grey
20310.10.B 20310.15.B 20310.20.B white
20310.10.N 20310.15.N 20310.20.N Next
Coaxial F-type socket outlet20318 .B .N
Coaxial socket outlet with F-type female connector (IEC 60169-24).For frequencies up to 2400 MHz. In/out connection with F-type male connector 01654
Terminal resistor16330
Z75terminalresistorforTV-RD-SATsocketoutletslineend,forfrequenciesupto2400MHz 30,5 11 22,3
20318 grey
20318.B white
20318.N Next
16330
Side views show the overall dimensions and the flush depth in mm Mounting boxes, frames and cover plates, page 189
59
SwitchesAcoustic and optical signalling Bells and buzzers12 V bells and buzzers are to be supplied through safety isolating transformer.
TECHNICAL CHARACTERISTICS Technical specificationsD-typeequipments:thesoundemissionhasthesamelasting time as the control operation Intermittentsound15/60:thesoundemissioncanlastupto ma
top related