Today’s Objective
To prepare you on what to expect from a CSI Field Inspection and provide an overview of how and what measurements are taken by an inspector.
4
EPBB Calculator
• Online tool that estimates the expected production of the systemand is used to determine the CSI incentive amount
• Takes into consideration equipment, location, orientation, tilt,shading effects and standoff height
• Measures the proposed system against an optimal system
• Derates the proposed system by a certain percentage (0-100%), referred to as the Design Factor, for any factors affecting the expected performance.
http://www.csi-epbb.com/
5
Filling Out the EPBB Calculator
• Required Field Measurements & Tools Used
• Standoff Height (Tape Measure)
• Shading (SolMetric SunEye, Solar Pathfinder, other)
• Tilt (Digital Level)
• True Azimuth (Compass)
7
Standoff Height
• Standoff Height - perpendicular distance from roof to the bottom of the module frame
• If not parallel to roof, use average height as shown below
Frame
6”
3”
(6”+3”)/2=4.5”
(SMAX)
(SMIN)
Mounting Method Choices:
0”
>0” to 1”
>1” to 3”
>3” to 6”
>6”
Please note: If the Mounting Method is not selected on the EPBB Calculator, it will automatically default to greater than 6” which can result
in an incorrect design factor
8
Minimal Shading and Solar AccessObstructions such as trees, chimneys or nearby buildings can cast shadows on PV systems, which can reduce the system’s sun access thereby reducing the amount of electricity the system will generate.
You must indicate on the EPBB Calculator whether there is shading that will have an impact or not.
Option 1: Minimal Shading
• Minimal Shading-requires at least a 2:1 distance to height ratio of any object within the orientation of sun to the panels.
A
B
A > (2 X B)
For example, if line B is 13 feet, then line A has to be 26 feet or more
9
If Not Minimal Shading…
Option 2: Not Minimal Shading, Enter Solar Access Values
• If a system does not satisfy the minimal shading requirement, a shading analysis needs to be performed to generate monthly solar access values.
• Solar access can be measured with tools such as the Solar Pathfinder or Solmetric SunEye (available at Pacific Energy Center to loan, visit www.pge.com/myhome/edusafety/workshopstraining/pec/toolbox/tll/)
• Measurements should be take at every major corner, but should not be more than 40 feet apart.
11
Tilt
• Tilt - Angle at which the modules are mounted relative to 0º (flat horizontal surface)
• Modules that are installed on a flat roof will have a 0ºtilt
tilt angleº
Frame
Ex. 30º
12
True AzimuthTrue Azimuth – the angle, usually measured in degrees(°), between a reference point
(True North Point 0°) and the direction of interest (direction panels are facing)
• The magnetic azimuth is measured using a compass, which does not represent the true north point because of the Earth’s magnetic fields
• Therefore, the magnetic azimuth must be corrected by adding (in Western U.S.) the magnetic declination of a specific location to give true azimuth
Magnetic DeclinationMagnetic North on a
Compass
13
Magnetic Declination Correction• Look up magnetic declination for specific location at:
(http://www.ngdc.noaa.gov/geomagmodels/Declination.jsp)
• Enter in zip code, and it will calculate the magnetic declination for that location.
For example:
If you are in San Francisco and your compass shows you a reading of 180°,
you would look up the zip code (e.g. 94105) and add the given correction for magnetic declination of 14° to get a true
azimuth of 194°
On EPBB Calculator, enter the azimuth as 194°
14
Tips for Determining Azimuth• Try to stay 10-15 ft away from metal, motors,
rooftop package units or magnets
• Store compasses away from cell phones and magnets
• Do not place compass directly on module or racking in case there are any magnetic fields present
• Check reading against tools like GoogleEarth. There is no azimuth function, but it can be used to provide sanity check for azimuth.
15
Multiple EPBB Calculators
• Multiple EPBB Calculators are needed when there are multiple arrays that differ in one or more of the following:
• Stand-off Height
• Shading
• Tilt
• True Azimuth
• Panel manufacturer and/or model
• Inverter manufacturer and/or model
16
28 panels:
Azimuth - South 180º
Tilt - 21º from horizontal Neighbor’s tree
3
21
4
Case Study 1
3
21
4
One array with the same:•modules and inverter(s)•stand-off height •shading•azimuth•tilt
Take 4 SunEye Snapshots, one at each corner of the
array
17
Case Study 1: Calculate Solar Access Averages
Each snapshot will generate 12 monthly Solar access values
Jan 84%
Feb 89%
Mar 92%
Apr 93%
May 94%
June 95%
July 97%
Aug 96%
Sept 94%
Oct 92%
Nov 91%
Dec 89%
Array 1: Solar access values are averaged
for points 1-4
18
Case Study 1: Calculate ImpactBecause entire array has the same stand-off height, shading,
azimuth, tilt and equipment, it is fine to complete only one
EPBB Calculator using averaged monthly solar access
values from the 4 points.
Array has 28 panels
19
Case Study 2
9 panels:
Azimuth - East 90º
Tilt - 17º from horizontal
21 panels:
Azimuth - South 180º Tilt
- 21º from horizontal
Neighbor’s tree
1
23
4
7
56
8
•Two arrays with the same module types and same inverter(s)
•Two arrays with different shading, azimuths and tilts•Take 8 SunEye Snapshots, one at each corner of each array
20
Case Study 2: Calculate Solar Access Averages
Jan 89
Feb 90
Mar 92
Apr 93
May 94
June 95
July 97
Aug 96
Sept 94
Oct 92
Nov 91
Dec 89
Array 1: Solar access values
are averaged for points 1-4
Array 2: Solar access values
are averaged for points 5-8
Each snapshot will generate 12 monthly Solar access values
Jan 90
Feb 91
Mar 92
Apr 93
May 94
June 95
July 96
Aug 96
Sept 95
Oct 93
Nov 92
Dec 91
21
Case Study 2: Calculate Impact
Array #1 has 9 panels
Because the two arrays have the different shading azimuths and tilts, two separate EPBB Calculator submittals are required - one for each array of unique orientation.
Array # 2 has 21 panels
22
Field Verification• Field measurements should be verified pre and
post installation for accuracy• If changes have been made after installation is
complete, a new EPBB calculator must be submitted
• The following measurements must also be verified in the field post installation by the contractor*• Primary Method
• Solar Irradiance (Irradiance Meter)• Temperature (Thermometer)• Inverter Output
• Compare to Field Verification Output Table (next page)*Method used by our inspectors
25
CSI Field Verification Inspections
Purpose• To verify that the project is installed as represented in
the Incentive Claim Form/Final EPBB Calculator, is operational, is interconnected and meets the eligibility criteria of the CSI Program.
26
Selection of CSI Projects for Site Inspections
First two Incentive Claim Forms submitted by a contractor will beinspected
Projects <50 kW:
• After two successful inspections, projects will be randomly chosen for inspection
• Random means approximately 1 in 7 applications per applicant
Projects >50 kW:
• Program administrator’s discretion
27
CSI Inspection Verification
Inspectors will verify the following:
Module & Inverter Equipment
- Manufacturer
- Model Number
- Quantity
*If module nameplate is not visible, invoice is necessary to verify manufacturer and model
Installation Parameters Verified
Measure:
- Tilt
- Azimuth
- Standoff Height
- Shading of array(s)
-Solar Irradiance
-Ambient Temperature
Operation
- System is Interconnected, operational, and output is reasonable for conditions at time of inspection
28
Coordination of InspectionsApplicants are not required to attend inspections, though they are highly encouraged to do so, especially…
• For first time Applicants
• For projects with significant shading
Inspector will require physical access to the equipment
• Inspector will contact Applicant for notification of inspection
• Inspectors prefer that the Applicant coordinates with the Host Customer to allow access
• If Applicant prefers, the Inspector will coordinate with the Host Customer.
29
Access Issues to Modules
If issues exist that prohibit access, such as
• Weather conditions that may render it unsafe to mount roof
• Roof that are too steep or have other structural issues, etc.
We will require assistance from Applicant by
• Providing Inspector shading analysis for EPBB Calculator
• Providing Inspector invoice indicating the module manufacturer, model and quantity
Inspector will still verify if the system output from the inverter is reasonable given the conditions during the inspection
30
Inspection Results• Inspector will verify measurements are within the following tolerances:
• Tilt +/- 3º
• Azimuth +/- 5º
• Shading +/- 5%
• If inspection results fall within tolerances• Inspector will accept EPBB calculator as submitted with the Incentive Claim
Form and send report to PG&E• PG&E will pay incentive as requested in the Incentive Claim Form
• If inspection results fall outside of tolerances• Inspector will communicate discrepancies to Applicant onsite, if present
during inspection• Inspector will run a new EPBB calculator to get a revised CSI rating and
incentive amount• Inspector will send it along with the report to PG&E for further evaluation
31
Inspection Results Cont’d
• PG&E will compare recalculated incentive to submitted incentive amount in Incentive Claim/EPBB Calc.
•If incentive amount discrepancy is within 5%
•PG&E will pay revised incentive amount based on new EPBB Calculator from inspection
•If incentive amount discrepancy is 5 -10%
•An Infraction will be issued
•If incentive amount discrepancy greater than 10%
•A Failure will be issued
32
Infractions and Failures
• If an Infraction or Failure is issued, the following two options will be communicated to the Applicant and Host Customer and a decision must be made within 30 days:
1. Applicant can accept new recalculated incentive amount
2. Applicant can dispute the accuracy of results/measurements
33
Infractions/Failures Cont’d
• 3 Issued Infractions = Failure• Low volume Installer (< 200 systems per year Statewide)
• 1 failure = warning• 2 failures = up to 100% inspection for Applicant’s projects• 3 failures = Disqualification for up to 1 year from CSI Program
• High volume Installer (> 200 systems per year Statewide)• 4 failures = up to 100% inspection for Applicant’s projects• 5 failures = Disqualification for up to 1 year
• All infractions/failures removed after good standing for 1 year of last failure
34
How to Prevent Failed Inspections• Make sure Incentive Claim Form and EPBB Calculator
accurately reflect “as-built” system
• If any changes occur, send updated EPBB Calculator to
Program Administrator before the inspection occurs
• Revised EPBB Calculators will not be accepted by Inspectors
on-site
• Attend the inspection to familiarize yourself with the inspection
process and program requirements
36
Future Webinars/Classes
• Tue, Oct 13, 5-6pm-PG&E and Solar-Internet
• Wed, Oct 14, 6-8pm-Solar Power Basics for Residential Customers-SF PEC
• Wed, Oct 14, 9am-12pm-Integrating Energy Efficiency and Renewables in Commercial Retrofits-SF-PEC
• Fri, Oct 16, 9am-4:30pm-Basics of Photovoltaic (PV) Systems for Grid-Tied Applications-Stockton—ETC
•Tue, Oct 20, 12-1pm-Financial Analysis-Internet
• Tue, Oct 20, 6pm-8pm-Solar Water Heating Basics-SF PEC
top related