data sheet - electro-energy
Post on 18-Dec-2021
1 Views
Preview:
TRANSCRIPT
KRONOTERM Data sheetHeat pump ADAPT
KRONOTERM Data sheetHeat pump ADAPT 32
98-19-24-5421-08 98-19-24-5421-08
Data sheet - ADAPT - ENG/98-19-24-5421-08
Printed in Slovenia, Copyright by Kronoterm d.o.o.
This work is protected by copyright. Any use of this document outdoor of the Copyright and Related Rights Act and without the express consent of Kronoterm d.o.o. (hereinafter: Kronoterm) is illegal and punishable by fine. This version obviates all previous versions. We reserve the right to make changes.
Despite taking extensive care to ensure the accuracy of all pictures and descriptions, Kronoterm reserves the right to make corrections, changes to technical details, and changes to pictures with no prior notice. Information herein is given based on the latest available product information at the time of drafting and printing this product sheet. We also reserve the right to cease sales of an individual product or even the entire collection.
Pictures are symbolic and are only intended as a reference. Despite our efforts we cannot ensure that the products’ true colors will be faithfully represented in print and on electronic screens; similarly, dimensions and other graphic elements might be represented incorrectly. Products may differ from their visual representations. Write to info@kronoterm.com for any additional questions.
KRONOTERM Data sheetHeat pump ADAPT
KRONOTERM Data sheetHeat pump ADAPT 32
98-19-24-5421-08 98-19-24-5421-08
—TABLE OF CONTENTS
HEAT PUMP ADAPT ............................................................................................................4
Description ............................................................................... 4Usage ............................................................................................ 4Technology ............................................................................... 4
CONFIGURATION ............................................................................................................... 5
NOMENCLATURE ............................................................................................................... 5
OUTDOOR UNIT ADAPT ..................................................................................................6
Version ......................................................................................... 6Description and dimensions ........................................ 6Model marks ............................................................................ 6
OUTDOOR UNIT ADAPT ..................................................................................................7
Primary components .........................................................7
INDOOR UNIT HYDRO C ...............................................................................................8
Version ......................................................................................... 8Model marks ............................................................................ 8
INDOOR UNIT HYDRO C ..............................................................................................9
Primary components ........................................................ 9
INDOOR UNIT HYDRO S .............................................................................................. 10
Version ........................................................................................10Model marks ...........................................................................10
INDOOR UNIT HYDRO S ................................................................................................11
Primary components ........................................................11Configuration of the HYDRO S indoor unit ........11
BASIC KSM CONTROLLER ..........................................................................................12
Model marks ........................................................................... 12
EXPANSION KSM+ CONTROLLER ..........................................................................13
Model marks ........................................................................... 13
CONTROLLER KT-2A ...................................................................................................... 14
Model type ...............................................................................14
CLOUD.KRONOTERM .....................................................................................................15
TECHNICAL DATA - OUTDOOR UNIT .................................................................. 16
TECHNICAL DATA - INDOOR UNIT ....................................................................... 18
SOUND .................................................................................................................................... 19
RANGE OF OPERATION ..............................................................................................20
CAPACITY CURVES .........................................................................................................20
CAPACITY CURVES ...........................................................................................................21
CAPACITY CURVES ..........................................................................................................22
CAPACITY CURVES ..........................................................................................................23
CAPACITY CURVES ......................................................................................................... 24
BASIC PIPING AND INSTRUMENTATION DIAGRAM HYDRO C .......25
BASIC PIPING AND INSTRUMENTATION DIAGRAM HYDRO S ...... 26
KRONOTERM Data sheetHeat pump ADAPT
KRONOTERM Data sheetHeat pump ADAPT 54
98-19-24-5421-08 98-19-24-5421-08
Description
Together with the HYDRO indoor unit the Kronoterm ADAPT heat pumps form a comprehen-sive variable system, Adaptable in terms of both refrigerant and hydraulics, depending on the building’s heating needs. The outdoor unit, a compact air/water heat pump, is distinguished by extremely silent operation and premium design. ADAPT heat pumps are hermetically sealed and factory tested outdoor units that use a simple water source to transfer energy to the indoor unit. ADAPT heat pumps are distinguished by cutting-edge technology, specifications, and energy efficiency.
Usage
Heating, cooling, and making domestic hot water.
Technology
• MyDesign, the tailorable appearance of the outdoor ADAPT unit, gives customers plenty of choices for their favorite color and material.
• NMS™ – the Noise Management System – combines a large evaporator with minimal air resistance, a large variable-speed fan, special materials to dampen noise and vibration, premium construction, and a specially developed control logic to reduce noise to incredibly low levels.
• CWP™ – Complete Weather Protection – protects the evaporator’s surface and protective guards against climatic conditions while ensuring a constant and appropriate flow of air, first-level protection against indirect precipitation or flash freezes, small amounts of defrosting, higher efficiency, and more reliable operation. Their exceptional construction and advantageous height give ADAPT heat pumps the right amount of airflow through the evaporator even during snowstorms.
• IAH™ – Intelligent Adaptive Heating – completely adjusts your heat pump’s output based on the building’s requirements. Special control algorithms modify the temperature of the water in the heating system per the desired room temperature, the current ambient temperature indoor, and the current weather outdoor. The building’s response dictates at what capacity the ADAPT heat pump needs to work. This unrivaled flexibility means that your heat pump works constantly, silently, and – most importantly – comfortable.
• LowGWP™ – Kronoterm is one of the first manufacturers in the world to use the advanced refrigerant R452B in our systems, drastically reducing the use of fluorinated gases (F-gases). This refrigerant has a whopping 67% less GWP than the traditional refrigerants used in heat pumps.
• CDHRS™ – the Compressor Drive Heat Recovery System – is the compressor’s electronic motor, designed for twice the lifespan of traditional compressor motors. The specially designed system to recover waste heat helps achieve more than 96% efficiency.
• NZF™ – Near Zero Frost – the evaporator’s extremely large surface area means that it has very low specific load. This results in reduced extraction of humidity from the air and slower buildup of frost. Less frost means less defrosting, and therefore greater effective heating capacity for the heat pump, and ultimately increased efficiency for the whole system.
• ECL™ – Enhanced Compressor Lifetime – an approach that is usually used in large, industrial systems. The advanced oil recovery system ensures that the heat pump retains lubricant in its compressor, where it is most important. At the same time, the compressor range monitoring and protection system constantly keeps the system within safe parameters.
• MHW™ – Max Hot Water – heats the entire volume of water available in the integrated DHW tank. The indoor Hydro C unit, which features a 200 l DHW tank for domestic hot water, utilizes a special heat exchanger to easily heat larger quantities than comparable systems.
• HBS™ – Hydronically Balanced System – the Hydro C’s indoor unit has a 40 l integrated DHW tank, ensuring that the heating system is always hydronically balanced, and that enough energy is always available for defrosting.
• RCS™ – Remote System Charge – refills the hydronic system with water to the right pressure and is integrated in the Hydro unit. Refilling is either automatic with a command through the room unit, or from the web/mobile app.
—HEAT PUMP ADAPT
KRONOTERM Data sheetHeat pump ADAPT
KRONOTERM Data sheetHeat pump ADAPT 54
98-19-24-5421-08 98-19-24-5421-08
A
B2
B1
—CONFIGURATION
ADAPT heat pumps are combined with the HYDRO C and HYDRO S indoor units.
—NOMENCLATURE
ADAPT 0312 K3 HT / HK 3F
Adapt The name for a line of heat pumps
0312 Range of heat output in kW, 03 - 12
0416 Range of heat output in kW, 04 - 12
0724* Range of heat output in kW, 07 - 18
K Water connection
3 Device generation
Indoor compact HYDRO C unit
Indoor HYDRO S wall unit
Outdoor unit ADAPT
Legend
A Outdoor unitB1 Indoor HYDRO S wall unitB2 Indoor compact HYDRO C unit
ADAPT 0312 K3 HT / HK 3F
HT Temperature of flow outlet up to 67 °C
HK Healing and cooling
3F / 1F three-phase electrical connection 3 x 400 V/ one-phase connection 1 x 230 V
HYDRO C
HYDRO The name for a line of indoor units
C A hydro module with an integrated DHW and buffer tank
S A basic, wall-mounted hydro module
*The ADAPT 0724 outdoor unit cannot be used with the Hydro C indoor unit
KRONOTERM Data sheetHeat pump ADAPT
KRONOTERM Data sheetHeat pump ADAPT 76
98-19-24-5421-08 98-19-24-5421-08
SPREDAJ
1050
140
0
2
1
27190
319
SMER ZRAKA
675
98
319
ZADAJ
AIR
BACK
FRONT
—OUTDOOR UNIT ADAPT
Legend
1 Inlet to the outdoor unit – flow outlet* - G 5/4"2 Outlet from the outdoor unit – flow inlet* - G 5/4"
*flat seal screw
VersionCompact outdoor air/water unit.
Description and dimensions• Powder coated, zinced, steel plate
housing• Optionally made out of stainless steel or
Corten sheet metal• Evaporator and fan protected against
the weather• Bionically designed fan to minimize
noise• Adjustable heat output• Adaptive heating• Integrated circulation pump• A large surface evaporator with a large
gap between the fins• Special acoustically insulated housing
Model marksADAPT 0312 K3 HT / HK 3F ADAPT0312 K3 HT / HK 1F ADAPT 0416 K3 HT / HK 3F ADAPT 0416 K3 HT / HK 1F ADAPT 0724 K3 HT / HK 3F
KRONOTERM Data sheetHeat pump ADAPT
KRONOTERM Data sheetHeat pump ADAPT 76
98-19-24-5421-08 98-19-24-5421-08
A
B
C
D
F
2
1
E
I
H
G
J
M
L
K
—
OUTDOOR UNIT ADAPT
Primary components
Legend1 Inlet to the outdoor unit door unit – G 5/4''*2 Outlet from the outdoor unit – G 5/4''*A Electronic expansion valveB DehydratorC VentilatorD EC Flow pumpE EvaporatorF Flow switchG FanH CompressorI Inverter driveJ Condensation dischargeK Outdoor unit’s controller’s electrical cabinetL Plate heat exchanger/CondenserM Connection for electricity and communication
with outdoor unit
*flat seal screw
KRONOTERM Data sheetHeat pump ADAPT
KRONOTERM Data sheetHeat pump ADAPT 98
98-19-24-5421-08 98-19-24-5421-08
700
1920
1 2 3 4
700
200
604
274 70
93 140
265
53
1
2
7
6
9
4
8
3
5
—INDOOR UNIT HYDRO C
Legend
1 Inlet (from outdoor unit) – G1''*
2 Outlet (to outdoor unit) – G1''*
3 Heating/cooling the return pipe – G1''*
4 Heating/cooling the supply pipe – G1''*
5 Circulation – G3/4''*
6 Domestic hot water – outlet – G3/4''*
7 Domestic cold water – inlet – G3/4''*
8 Cable glands for electricity
9 Internet cable
*flat seal screw
VersionIndoor unit with DHW tank and buffer tank.
Model marksHYDRO C
Description and dimensions• Powder coated, zinced, steel plate
housing• Healing and cooling• Integrated 200 l DHW tank • Integrated buffer tank, 40 l• Integrated expansion vessel for the
heating system (18 l) and hot water (12 l)• Integrated safety valve for the heating
system and domestic hot water• Integrated 6 kW electrical heater • (3 x 2 kW)• Integrated magnetic valve• Integrated pressure sensor and system
refiller• KSM, KSM+, and WEB module • controllers
KRONOTERM Data sheetHeat pump ADAPT
KRONOTERM Data sheetHeat pump ADAPT 98
98-19-24-5421-08 98-19-24-5421-08
G
H
N
O
P
M
I
J
K
L
D
A
E
B
F
C
—INDOOR UNIT HYDRO C
Primary components
Legend
A Magnetic filter
B Safety valve for DHW
C Safety valve for heating
D Pressure sensor
E 6 kW electrical heater (3 x 2 kW)
F Flow sensor (optional)
G Electric cabinet
H DHW expansion vessel – 12 l
I 3-way zone valve
J Expansion vessel for heating – 18 l
K Heating/cooling buffer tank – 40 l
L Condensate vessel
M DHW tank – 200 l
N Heat exchanger for heat transfer for domestic hot water
O Motorized valve for filling the heating system
P Flow pump for DHW water
KRONOTERM Data sheetHeat pump ADAPT
KRONOTERM Data sheetHeat pump ADAPT 1110
98-19-24-5421-08 98-19-24-5421-08
6470
0
525
9
1
5
4
10
3
2
8
1 2 3 4 5
100 100 100 10063 63
350
—INDOOR UNIT HYDRO S
Legend
1 Outlet (to outdoor unit) – G 5/4''*2 Inlet (from outdoor unit) – G 5/4''*
3 Heating/cooling, DHW - supply pipe – G 5/4''*4 Heating/cooling return pipe – G 5/4''*
5 Heating/cooling supply pipe – G 5/4''*8 Glands for electric cables9 Internet cable10 Condensation discharge – ø 16
*flat seal screw
VersionBasic indoor wall unit
Model marksHYDRO S
Description and dimensions• Wall-mounted indoor unit• Integrated 6 kW electrical heater
(3 x 2 kW)• Integrated 3–way valve for switching
between heating and DHW• Integrated magnetic filter and pressure
sensor• KSM and KSM+ controller• Integrated WEB module• Drawer for documentation
KRONOTERM Data sheetHeat pump ADAPT
KRONOTERM Data sheetHeat pump ADAPT 1110
98-19-24-5421-08 98-19-24-5421-08
E
A
F
C
B
D
HYDRO S + HYDRO A+ HYDRO P
—INDOOR UNIT HYDRO S
Primary components
Legend
A 3-way zone valve
B Magnetic filter
C 6 kW electrical heater (3 x 2 kW)
D Flow sensor (optional)
E Electrical cabinet for controller KSM, KSM+
F Heating system’s pressure sensor
Configuration of the HYDRO S indoor unit
HYDRO SBasic configuration
HYDRO S + HYDRO ABasic version with console spacer for pipe connection
HYDRO S + HYDRO PVersion with 40 l buffer tank
HYDRO S + HYDRO A + HYDRO PModel with buffer tank of 40l and pipe spacers
KRONOTERM Data sheetHeat pump ADAPT
KRONOTERM Data sheetHeat pump ADAPT 1312
98-19-24-5421-08 98-19-24-5421-08
—BASIC KSM CONTROLLER
Model marksKSM*
Description• Modular controller for regulating the
heat pump and heating system• Managing your system is either
automatic with a command through the KT-2A room unit, or from the web/mobile Home.Cloud app.
Functional characteristics• Managing and protecting heat pumps• Operational status display• Service access and error correction• Preparing domestic hot water• Thermal disinfection of domestic hot
water• Weather controlled via outdoor
temperature sensor• Active cooling• Control functions for:
· 1 x direct loop · 1 x direct or mixing loop · Heating DHW water · Circulating DHW water · Daily and weekly schedules
· Adaptive curve after individual loops · Room temperature regulation with the Kronoterm KT-1 and KT-2A thermostats.
• Controlling additional sources of heat (gas, oil, and pellets)
• Photovoltaic (PV) program• Screed-drying program• WEB module for internet connection
(UTP 5e cable – RJ45 connection – Ethernet)
• BMS connection via MODBUS protocol RS 485
• SG (Smart Grid) ready.
*Kronoterm System Manager
KRONOTERM Data sheetHeat pump ADAPT
KRONOTERM Data sheetHeat pump ADAPT 1312
98-19-24-5421-08 98-19-24-5421-08
—EXPANSION KSM+ CONTROLLER
Model marksKSM+*
Description• Expansion module as an upgrade to the
basic controller • Possible installation of one expansion
module (1x)• Integration in the HYDRO C or HYDRO S
indoor unit
*Kronoterm System Manager +
Functional characteristics
• Managing 2 additional loops (direct or mixed)
• Regulating SSE sunlight collectors• Managing biomass boilers• Preparing DHW with sunlight
collectors or biomass boilers• Heating pools• Heating pools with sunlight
collectors
KRONOTERM Data sheetHeat pump ADAPT
KRONOTERM Data sheetHeat pump ADAPT 1514
98-19-24-5421-08 98-19-24-5421-08
—CONTROLLER KT-2A
Model typeKT-2A
Description• Controller for regulating heat pump
and heating system.• Operation and protection of the heat
pump.• Choice of operating mode, controller
and / or thermostat.• Display operating statuses.• Service access and debugging.• The KT-2A controller can, operate in
three different operations:• Thermostat• Controller of heat pump and heating
system• Thermostat and controller of heat
pump combined and as controller of heating system
KRONOTERM Data sheetHeat pump ADAPT
KRONOTERM Data sheetHeat pump ADAPT 1514
98-19-24-5421-08 98-19-24-5421-08
.......................
Cloud.KRONOTERM
OK
—CLOUD.KRONOTERM
Remotely controlling and monitoring the ADAPT system with the pertinent HYDRO indoor unit, along with heating, cooling, and preparing DHW via cloud technology.
KRONOTERM Data sheetHeat pump ADAPT
KRONOTERM Data sheetHeat pump ADAPT 1716
98-19-24-5421-08 98-19-24-5421-08
—TECHNICAL DATA - OUTDOOR UNIT
DEVICE Unit ADAPT 0312 ADAPT 0416 ADAPT 0724
INDOOR UNIT
Model Hydro S, Hydro C Hydro S, Hydro C Hydro S
VERSION
Heat source primary side Air Air Air
Heat sink secondary side Water Water Water
Controller KSM KSM KSM
Placement of the heat pump Outdoor Outdoor Outdoor
Placement of the controller unit Indoor Indoor Indoor
Compressor 1 x scroll, variable speed 1 x scroll, variable speed 1 x scroll, variable speed
Compressor drive Inverter Inverter Inverter
Fan Axial Axial Axial
Defrost Active (change of direction of the cooling loop) Active (change of direction of the cooling loop) Active (change of direction of the cooling loop)
Circulation pump, sink Integrated Integrated Integrated
CAPACITY ACCORDING TO EN 14511 (1F version)
HEATING Heating capacity / electrical power / COP Heating capacity / electrical power / COP Heating capacity / electrical power / COP
A7/W30-35 Nominal kW / kW / - 6,08 / 1,12 / 5,45 8,48 / 1,51 / 5,60 /
A2/W30-35 Nominal kW / kW / - 6,55 / 1,48 / 4,42 8,57 / 1,92 / 4,46 /
A-7/W30-35 Maximal kW / kW / - 8,44 / 2,67 / 3,17 11,12 / 3,67 / 3,03 /
A-10/W30-35 Maximal kW / kW / - 8,00 / 2,63 / 3,04 11,12 / 3,72 / 2,99 /
A7/W47-55 Nominal kW / kW / - 5,87 / 1,91 / 3,08 7,78 / 2,43 / 3,20 /
A2/W47-55 Nominal kW / kW / - 5,90 / 2,12 / 2,78 7,79 / 2,83 / 2,75 /
A-10/W47-55 Maximal kW / kW / - 7,41 / 3,70 / 2,01 10,61 / 5,32 / 1,99 /
COOLING Cooling capacity / electrical power / EER Cooling capacity / electrical power / EER Cooling capacity / electrical power / EER
A35/W12-7 kW / kW / - 7,27 / 2,85 / 2,56 10,21 / 3,91 / 2,61 /
A35/W23-18 kW / kW / - 7,44 / 1,88 / 3,96 10,40 / 2,60 / 4,01 /
CAPACITY ACCORDING TO EN 14511 (3F version)
HEATING Heating capacity / electrical power / COP Heating capacity / electrical power / COP Heating capacity / electrical power / COP
A7/W30-35 Nominal kW / kW / - 6,02 / 1,11 / 5,41 8,50 / 1,53 / 5,55 12,94 / 2,39 / 5,42
A2/W30-35 Nominal kW / kW / - 6,56 / 1,47 / 4,47 8,41 / 1,89 / 4,49 12,43 / 2,98 / 4,17
A-7/W30-35 Maximal kW / kW / - 8,52 / 2,62 / 3,25 10,96 / 3,49 / 3,14 15,71 / 5,61 / 3,05
A-10/W30-35 Maximal kW / kW / - 8,05 / 2,59 / 3,11 10,99 / 3,53 / 3,11 15,60 / 5,20 / 3,00
A7/W47-55 Nominal kW / kW / - 5,87 / 1,92 / 3,06 7,81 / 2,40 / 3,26 13,13 / 3,91 / 3,36
A2/W47-55 Nominal kW / kW / - 6,18 / 2,27 / 2,73 7,70 / 2,77 / 2,78 13,44 / 4,51 / 2,98
A-10/W47-55 Maximal kW / kW / - 7,48 / 3,67 / 2,04 10,29 / 5,03 / 2,04 15,6 / 5,20 / 3,01
COOLING Cooling capacity / electrical power / EER Cooling capacity / electrical power / EER Cooling capacity / electrical power / EER
A35/W12-7 kW / kW / - 7,27 / 2,85 / 2,56 10,21 / 3,91 / 2,61 16,96 / 7,37 / 2,30
A35/W23-18 kW / kW / - 7,44 / 1,88 / 3,96 10,40 / 2,60 / 4,01 17,48 / 4,83 / 3,62
SEASONAL CAPACITY IN THE HEATING MODE FOR EUROPEAN AVERAGE CLIMATE AREA ACCORDING TO EN 14825 (1F version)
SCOP, 35°C / 55 °C 5,08 / 3,65 5,12 / 3,75 /
SEASONAL CAPACITY IN THE HEATING MODE FOR EUROPEAN AVERAGE CLIMATE AREA ACCORDING TO EN 14825 (3F version)
SCOP, 35°C / 55 °C 4,92 / 3,57 5,20 / 3,66 4,94 / 3,83
SEASONAL ENERGY EFFICIENCY IN THE SPACE HEATING MODE FOR EUROPEAN AVERAGE CLIMATE AREA ACCORDING TO (EU) 811/2013 (1F version)
Rated heating capacity Pdesignh, 35°C / 55 °C kW 8 / 7 11 / 10 /
ηs, 35°C / 55°C % 194 / 139 197 / 144 /
SEASONAL ENERGY EFFICIENCY IN THE SPACE HEATING MODE FOR EUROPEAN AVERAGE CLIMATE AREA ACCORDING TO (EU) 811/2013 (3F version)
Rated heating capacity Pdesignh, 35°C / 55 °C kW 8 / 8 11 / 10 16 / 16
ηs, 35°C / 55°C % 188 / 137 201 / 141 195 / 150
KRONOTERM Data sheetHeat pump ADAPT
KRONOTERM Data sheetHeat pump ADAPT 1716
98-19-24-5421-08 98-19-24-5421-08
DEVICE Unit ADAPT 0312 ADAPT 0416 ADAPT 0724
ENERGY CONSUMPTION DESIGNATION FOR EUROPEAN AVERAGE CLIMATE AREA
Room heating energy class 35 °C / 55 °C A+++ / A++ A+++ / A++ A+++ / A+++
Room heating system energy 35 °C / 55 °C A+++ / A++ A+++ / A++ A+++ / A+++
ELECTRICAL DATA 1F
OUTDOOR AND INDOOR UNIT
Max. electrical power of 1F connection*Max. electrical power of 1F connection* kW 8,7 9,8 /
OUTDOOR UNIT
Nominal voltage ~ 230 V; 50 Hz ~ 230 V; 50 Hz /
Max. operation current A 18,6 23,1 /
Max. electrical power* kW 4,1 5,2 /
Fuses A 1 x C20 1 x C25 /
Electrical power cable*** mm2 3 x 2,5 (H05VV-F) 3 x 4,0 (H05VV-F) /
ELEKTRISCHE DATEN 3F
OUTDOOR AND INDOOR UNIT
Max. electrical power of 1F connection**Max. electrical power of 1F connection** kW 11,1 12,8 16
OUTDOOR UNIT
Nominal voltage 3N~ 400 V; 50 Hz 3N~ 400 V; 50 Hz 3N~ 400 V; 50 Hz
Max. operation current A 7,6 10,4 17
Max. electrical power* kW 4,5 6,2 9
Fuses A 3 x C10 3 x C10 3 x C20
Electrical power cable*** mm2 5 x 2,5 (H05VV-F) 5 x 2,5 (H05VV-F) 5 x 4,0 (H05VV-F)
COMMUNICATION
Connection between outdoor and indoor unit FTP 5e Kabel / 2x2x0,6 mm2 (LiYCY) FTP 5e Kabel / 2x2x0,6 mm2 (LiYCY) FTP 5e Kabel / 2x2x0,6 mm2 (LiYCY)
COOLING SYSTEM
Refrigerant - type R 452 B R 452 B R 452 B
GWP (global warming potential) 676 676 676
Refrigerant - quantity kg 2,9 4,2 5,0
Max. Operating pressure MPa 4,5 4,5 4,5
PRIMARY SIDE (HEAT SOURCE) – AIR
Air flow m3/h variable variable variable
SECONDARY SIDE (HEAT SINK) – WATER
INTEGRATED CIRCULATION PUMP
Max. pressure capacity kPa 80 80 100
Max. flow m3/h variable variable variable
Max. electrical power W 75 75 140
HEATING
Operating envelope - min. / max. water temperature °C -25 / 40 -25 / 40 -25 / 40
COOLING
Operating envelope - min. / max. water temperature °C 0 / 40 0 / 40 0 / 40
DIMENSIONS AND MASS - TRANSPORT
Dimensions (W x H x D) mm 1150 x 1550 x 770 1150 x 1550 x 770 1150 x 1550 x 770
Mass 3F kg 263 272 282
Mass 1F kg 253 262 /
DIMENSIONS AND MASS - NET
Dimensions (W x H x D) mm 1050 x 1400 x 675 1050 x 1400 x 675 1050 x 1400 x 675
Mass 3F kg 240 249 259
Mass 1F kg 230 239 /
*This information is for use with an activated 4 kW electric heater.**This information is for use with an activated 6 kW electric heater.***Tu = 0°C / Tk = 60°C / f = 120 Hz
KRONOTERM Data sheetHeat pump ADAPT
KRONOTERM Data sheetHeat pump ADAPT 1918
98-19-24-5421-08 98-19-24-5421-08
—TECHNICAL DATA - INDOOR UNIT
INDOOR UNIT (HM) Unit Hydro S Hydro C
ELECTRICAL DATA 1F
1F CONNECTION OF INTERNAL UNIT
Frequency Hz 50 50
Rated voltage V ~ 230 V ~ 230 V
Electrical boiler 1 x 2 kW ~ 230 V 2 x 2 kW ~ 230 V 1 x 2 kW ~ 230 V 2 x 2 kW ~ 230 V
Max. operational current A 11,8 20,6 11,8 20,6
Max. electrical power kW 2,6 4,6 2,6 4,6
Fuses A 1 x C16 1 x C20 1 x C16 1 x C20
Electrical power cable*Tu = 0°C / Tk = 60°C / f = 120 Hz mm2 3 x 2,5 3 x 4 3 x 2,5 3 x 4
3F CONNECTION OF INTERNAL UNIT
Frequency Hz 50 50
Rated voltage V 3N ~ 400 3N ~ 400
Electrical boiler A 11,8 11,8
Max. operational current kW 6,6 6,6
Max. electrical power A 3 x C16 3 x C16
Fuses mm2 5 x 2,5 5 x 2,5
Electrical power cable*Tu = 0°C / Tk = 60°C / f = 120 Hz 3 x 2 kW ~ 230 V 3 x 2 kW ~ 230 V
SECONDARY SIDE (HEAT SINK) - WATER
Recommended dimensions of pipes of the device 0312 & 0416 DN 25 25
Recommended dimensions of pipes of the device 07/24 DN 32 /
VOLUME
DHW Tank l / 200
Buffer tank l 40 40
DIMENSIONS AND MASS - NET
Dimensions (W x H x D) mm 610 x 790 x 530 640 x 2120 x 790
Mass kg 44 211
ABMESSUNGEN – NETO
Dimensions (W x H x D) mm 525 x 700 x 350 605 x 1925 x 700
Mass kg 34 197
COMMUNICATION
Connection between ext. and inter. unit FTP 5e Kabel / 2x2x0,6 mm2 (LiYCY) FTP 5e Kabel / 2x2x0,6 mm2 (LiYCY)
Connection to BMSMODBUS protocol (UTP cable –
connection RJ45) – RS 485MODBUS protocol (UTP cable –
connection RJ45) – RS 485
Connection to the internet UTP cable – connection RJ45 - Ethernet UTP cable – connection RJ45 - Ethernet
KRONOTERM Data sheetHeat pump ADAPT
KRONOTERM Data sheetHeat pump ADAPT 1918
98-19-24-5421-08 98-19-24-5421-08
5m 10m1m
—SOUND
Description• Sound power is a characteristic of a sound
source and is not related to distance; describes the total sound energy of an appropriate source that is emitted in all directions.
• Sound pressure depends on the measurement site in the sound field and describes the sound pressure at that location.
• Structural sound is transmitted by structure, so all connectors must be equipped with vibration compensators or absorbers.
• It is very important for the outdoor unit to choose the right location. Adjacent walls and other obstructions around the device significantly affect the sound pressure.
DEVICE Unit ADAPT 0312 ADAPT 0416 ADAPT 0724
SOUND ACCORDING TO EN 12102 AT THE CONDITION OF A7W35
ECOLABEL
Sound power dB (A) 44 46 53
The sound pressure at the distance of 1 m dB (A) 36 38 45
The sound pressure at the distance of 5 m dB (A) 22 24 31
The sound pressure at the distance of 10 m dB (A) 16 18 25
REDUCED
Sound power dB (A) 50 56 61
The sound pressure at the distance of 1 m dB (A) 42 48 53
The sound pressure at the distance of 5 m dB (A) 28 34 39
The sound pressure at the distance of 10 m dB (A) 22 28 33
MAXIMAL
Sound power dB (A) 55 61 67
The sound pressure at the distance of 1 m dB (A) 47 53 59
The sound pressure at the distance of 5 m dB (A) 33 39 45
The sound pressure at the distance of 10 m dB (A) 27 33 39
KRONOTERM Data sheetHeat pump ADAPT
KRONOTERM Data sheetHeat pump ADAPT 2120
98-19-24-5421-08 98-19-24-5421-08
—RANGE OF OPERATION
Heating
ADAPT 0312Heating capacity
ADAPT 0312Cooling capacity
Cooling
—CAPACITY CURVES
0
20
10
30
40
50
60
80
70
-30 -15-25 -20 -10 -5 0 5 10 15 20 25 30 454035
Temperatura zunanjega zraka [0C]
Tem
per
atu
ra iz
stop
ne
vod
e [0
C]
Ou
tlet
wat
er t
emp
erat
ure
[0C
]
Outdoor air temperature [0C]
1,0
2,0
5,0
7,0
6,0
3,0
4,0
8,0
9,0
10,0
-25 -20 -15 -10 -5 0 5 10 15
min 0C W 55 0C W 45 0C. . . . . . . . . . . .
W 35 0C - max
Temperatura zunanjega zraka [0C]
Gre
lna
moč
[kW
]H
eati
ng
cap
acit
y [k
W]
Outdoor air temperature [0C]
2,0
3,0
5,0
4,0
7,0
6,0
8,0
0 5 10 15 20 25 30 35 40
Hla
diln
a m
oč [k
W]
Temperatura zunanjega zraka [0C]
W 18 0CW 7 0C - max. . . . . . . . . . . .min 0C
Coo
ling
cap
acit
y [k
W]
Outdoor air temperature [0C]
0
10
5
15
20
25
30
-5 0 5 10 15 20 25 30 454035
Temperatura zunanjega zraka [0C]Te
mp
erat
ura
izst
opn
e vo
de
[0C
]O
utl
et w
ater
tem
per
atu
re [0
C]
Outdoor air temperature [0C]
KRONOTERM Data sheetHeat pump ADAPT
KRONOTERM Data sheetHeat pump ADAPT 2120
98-19-24-5421-08 98-19-24-5421-08
—CAPACITY CURVES
ADAPT 0416Heating capacity
ADAPT 0724Heating capacity
ADAPT 0416Cooling capacity
ADAPT 0724Cooling capacity
W 18 0CW 7 0C - max. . . . . . . . . . . .min 0C
Hla
diln
a m
oč [k
W]
Temperatura zunanjega zraka [0C]
5,06,0
9,0
11,010,0
7,0
8,0
12,013,0
14,015,0
19,0
16,0
17,018,0
0 5 10 15 20 25 30 35 40
Coo
ling
cap
acit
y [k
W]
Outdoor air temperature [0C]
min 0C W 55 0C W 45 0C. . . . . . . . . . . .
W 35 0C - max
2,0
3,0
6,0
8,0
7,0
4,0
5,0
9,0
10,0
11,0
12,0
13,0
-25 -20 -15 -10 -5 0 5 10 15
Temperatura zunanjega zraka [0C]
Gre
lna
moč
[kW
]H
eati
ng
cap
acit
y [k
W]
Outdoor air temperature [0C]
min 0C W 55 0C W 45 0C. . . . . . . . . . . .
W 35 0C - max
Temperatura zunanjega zraka [0C]
Gre
lna
moč
[kW
]
5,06,0
9,0
11,010,0
7,0
8,0
12,013,0
14,015,0
19,0
16,0
17,018,0
-25 -20 -15 -10 -5 0 5 10 15
Hea
tin
g c
apac
ity
[kW
]
Outdoor air temperature [0C]
W 18 0CW 7 0C - max. . . . . . . . . . . .min 0C
3,0
5,0
4,0
7,0
8,0
9,0
10,0
6,0
11,0
0 5 10 15 20 25 30 35 40
Hla
diln
a m
oč [k
W]
Temperatura zunanjega zraka [0C]C
oolin
g c
apac
ity
[kW
]Outdoor air temperature [0C]
KRONOTERM Data sheetHeat pump ADAPT
KRONOTERM Data sheetHeat pump ADAPT 2322
98-19-24-5421-08 98-19-24-5421-08
CAPACITY CURVES
ADAPT O312Heating capacity
Ou
tdoo
r ai
r te
mp
erat
ure
[0C
]
0,02,0 1,05,0
7,0
6,0
3,0
4,08,0
9,0
13,0
10,0
11,0
12,0
Heating capacity [kW]
AD
AP
T +
EH
(3 –
8%
)
AD
AP
T
T d
esig
n H
-16
0C
T d
esig
n H
-13
0C
T d
esig
n H
-7 0
C
-25
-23
-21
-19
-13
-15
-9-1
1-1
7-7
-5-3
13
79
1315
-15
1117
19
KRONOTERM Data sheetHeat pump ADAPT 19
W 5
5 0C
- m
inW
55
0C
- m
axW
45
0C
- m
axW
35
0C
- m
ax
Hea
tin
g c
apac
ity
wit
h E
GT
des
ign
H -1
6 0C
T d
esig
n H
-13
0C
T d
esig
n H
-7 0
C
The
reco
mm
end
ed r
ang
e of
dim
ensi
onin
g in
ral
atio
n t
o th
e p
roje
ct t
emp
EH
E
lect
ric
hea
ter
—CAPACITY CURVES
ADAPT 0312Heating capacity
KRONOTERM Data sheetHeat pump ADAPT
KRONOTERM Data sheetHeat pump ADAPT 2322
98-19-24-5421-08 98-19-24-5421-08
CAPACITY CURVES
ADAPT O416Heating capacity
0,02,0 1,05,0
7,0
6,0
3,0
4,08,0
9,0
16,0
10,0
11,0
12,0
13,0
14,0
15,0 -2
5-2
3-2
1-1
9-1
3-1
5-9
-11
-17
-7-5
-31
37
913
15-1
511
1719
Ou
tdoo
r ai
r te
mp
erat
ure
[0C
]
Heating capacity [kW]
T d
esig
n H
-16
0C
T d
esig
n H
-13
0C
AD
AP
T +
EH
(3 –
8%
)
AD
AP
T
T d
esig
n H
-7 0
C
20KRONOTERM Data sheet
Heat pump ADAPT
W 5
5 0C
- m
inW
55
0C
- m
axW
45
0C
- m
axW
35
0C
- m
ax
Hea
tin
g c
apac
ity
wit
h E
GT
des
ign
H -1
6 0C
T d
esig
n H
-13
0C
T d
esig
n H
-7 0
C
The
reco
mm
end
ed r
ang
e of
dim
ensi
onin
g in
ral
atio
n t
o th
e p
roje
ct t
emp
EH
E
lect
ric
hea
ter
—CAPACITY CURVES
ADAPT 0416Heating capacity
KRONOTERM Data sheetHeat pump ADAPT
KRONOTERM Data sheetHeat pump ADAPT 2524
98-19-24-5421-08 98-19-24-5421-08
W 5
5 0C
- m
inW
55
0C
- m
axW
45
0C
- m
axW
35
0C
- m
ax
Hea
tin
g c
apac
ity
wit
h E
GT
des
ign
H -1
6 0C
T d
esig
n H
-13
0C
T d
esig
n H
-7 0
C
The
reco
mm
end
ed r
ang
e of
dim
ensi
onin
g in
ral
atio
n t
o th
e p
roje
ct t
emp
EH
E
lect
ric
hea
ter
KRONOTERM Data sheetHeat pump ADAPT 21
CAPACITY CURVES
ADAPT O724Heating capacity
0,02,0 1,05,0
7,0
6,0
3,0
4,08,0
9,0
16,0
17,0
18,0
19,0
20,0
21,0
22,0
10,0
11,0
12,0
13,0
14,0
15,0 -2
5-2
3-2
1-1
9-1
3-1
5-9
-11
-17
-7-5
-31
37
913
15-1
511
1719
Ou
tdoo
r ai
r te
mp
erat
ure
[0C
]
Heating capacity [kW]
T d
esig
n -1
6 0CT d
esig
n -1
3 0C
AD
AP
T +
EH
(3 –
8%
)
AD
AP
T
T d
esig
n -7
0C
—CAPACITY CURVES
ADAPT 0724Heating capacity
KRONOTERM Data sheetHeat pump ADAPT
KRONOTERM Data sheetHeat pump ADAPT 2524
98-19-24-5421-08 98-19-24-5421-08
22KRONOTERM Data sheet
Heat pump ADAPT
BASIC PIPING AND INSTRUMENTATION DIAGRAM HYDRO C
Mar
ks le
gen
d
1 2 10 59 60 61
HY
DR
O C
wit
h in
teg
rate
d b
uff
er t
ank
and
DH
W t
ank
Hea
t p
um
p a
ir /
wat
er
Cir
cula
tion
pu
mp
Cir
cula
tion
pu
mp
set
for
dir
ect
hea
tin
g c
ircu
it
Cir
cula
tion
pu
mp
set
for
mix
ing
hea
tin
g c
ircu
it
Man
ifold
Sym
bol
s le
gen
d
Cir
cula
tion
pu
mp
Com
pre
ssor
Thre
e w
ay m
ixin
g v
alve
Thre
e w
ay z
one
valv
e
Tem
per
atu
re s
enso
r
Man
omet
er
Ther
mom
eter
Safe
ty t
her
mos
tat
Mag
net
ic d
irt
sep
arat
or
Bal
l val
ve
Safe
ty v
alve
Bal
anci
ng
val
ve
Ch
eck
valv
e
Ch
eck
Bal
l val
ve
Stra
iner
Exp
ansi
on v
esse
l
Air
ven
t
Flo
w e
lect
rica
l hea
ter
Hea
t ex
chan
ger
Filt
er
Pre
ssu
re r
egu
lato
r
A s
crew
con
nec
tion
wit
h a
scr
ewd
rive
r
Thre
aded
plu
g
Con
trol
ler
Flo
w
Ret
urn
Dom
esti
c co
ld w
ater
Dom
esti
c h
ot w
ater
Cir
cula
tion
El.
sup
ply
El.
sig
nal
(0,7
5 m
m2 )
Com
un
icat
ion
(FTP
5e)
1
2
5960
61
6060
1. ci
rcu
it
PLC
: TS
S1
2. c
ircu
it
PLC
: TS
S2
3. c
ircu
it
PLC
: TS
S6
4. c
ircu
it
PLC
: TS
S7
10
—BASIC PIPING AND INSTRUMENTATION DIAGRAM HYDRO C
KRONOTERM Data sheetHeat pump ADAPT
KRONOTERM Data sheetHeat pump ADAPT 2726
98-19-24-5421-08 98-19-24-5421-08
Flo
w
Ret
urn
Dom
esti
c co
ld w
ater
Dom
esti
c h
ot w
ater
Cir
cula
tion
El.
sup
ply
El.
sig
nal
(0,7
5 m
m2 )
Com
un
icat
ion
(FTP
5e)
Mar
ks le
gen
d
1 2 3 10 17 59 60 61
HY
DR
O S
Hea
t p
um
p a
ir /
wat
er
DH
W t
ank
Cir
cula
tion
pu
mp
Bu
ffer
tan
k
Cir
cula
tion
pu
mp
set
for
dir
ect
hea
tin
g c
ircu
it
Cir
cula
tion
pu
mp
set
for
mix
ing
hea
tin
g c
ircu
it
Man
ifold
Sym
bol
s le
gen
d
Cir
cula
tion
pu
mp
Com
pre
ssor
Thre
e w
ay m
ixin
g v
alve
Thre
e w
ay z
one
valv
e
Tem
per
atu
re s
enso
r
Man
omet
er
Ther
mom
eter
Safe
ty t
her
mos
tat
Mag
net
ic d
irt
sep
arat
or
Bal
l val
ve
Safe
ty v
alve
Bal
anci
ng
val
ve
Ch
eck
valv
e
Ch
eck
Bal
l val
ve
Stra
iner
Exp
ansi
on v
esse
l
Air
ven
t
Flo
w e
lect
rica
l hea
ter
Hea
t ex
chan
ger
Filt
er
Pre
ssu
re r
egu
lato
r
A s
crew
con
nec
tion
wit
h a
scr
ewd
rive
r
Thre
aded
plu
g
Con
trol
ler
KRONOTERM Data sheetHeat pump ADAPT 23
17
1
2
3
10
5960
61
6060
1. ci
rcu
it
PLC
: TS
S1
2. c
ircu
it
PLC
: TS
S2
3. c
ircu
it
PLC
: TS
S6
4. c
ircu
it
PLC
: TS
S7—BASIC PIPING AND INSTRUMENTATION DIAGRAM HYDRO S
KRONOTERM Data sheetHeat pump ADAPT
KRONOTERM Data sheetHeat pump ADAPT 2726
98-19-24-5421-08 98-19-24-5421-08
top related