condition assessment, durability and corrosion of … · session #6 “rock reinforcement ” ......

Post on 06-Jul-2020

4 Views

Category:

Documents

0 Downloads

Preview:

Click to see full reader

TRANSCRIPT

CONDITION ASSESSMENT, DURABILITY AND CORROSION OF ROCK REINFORCEMENTS

Kenneth L. Fishman, Ph.D., P.E.

17th ANNUAL TECHNICAL FORUM

GEOHAZARDS IMPACTING TRANSPORTATION IN THE APPALACHIAN REGION

Session #6

“Rock Reinforcement ”Blacksburg, VA

Wednesday, August 12, 2015

1

TOPICS1. Rock Reinforcement Types and Installation

Details2. Chronology of Rock Reinforcement Types3. Corrosion & Corrosion Protection4. Existing Performance Data5. NDT6. Service Life Modeling7. Conclusions

2

1. TYPES OF ROCK REINFORCEMENTS

System Type Tendon Type Anchorage Type Corrosion Protection

Rock Anchors Strands or BarsHigh Strength Steel

Cement Grout in Bonded Zone

Class I or Class II Protection

Rock Bolts Bars StrandsMild Steel or 150 ksi

Mechanical, resin grout or cement grout

Epoxy coating, galvanized, grout cover. May have no protection other than grout cover.

3

ROCK BOLTS

Mechanical anchorage

Grouted anchorage

4

Sledge & Wedge Rock Bolt

5

Expansion Shell Anchorage

6

Cement-Grouted Anchorage

7

Resin-Grouted Anchorage

8

Ground Anchor

9

10

2. CHRONOLOGY

10

3. TYPES OF CORROSION

Uniform corrosionPitting corrosionCrevice corrosionStress corrosion crackingHydrogen embrittlementStray-current induced

corrosionMicro-bacterial induced

corrosion 11

CORROSION PROTECTION SYSTEMS

12

Class II (PTI, 2007)

13

Class I (PTI, 2007)

14

4. LONG TERM PERFORMANCE OF ROCKBOLTS (Baxter, 1987; Kendorski, 2003 )

Finish Rockbolt Research (Sundholm, 1987)• Cracks, voids and lack of material were found in both cement

grouted and resin grouted bolts.• Large pieces of resin cartridge cover were seen between the

grout and the borehole wall.• Cement grouting of rebar seemed to offer the best protection

against corrosion.• For cement-grouted bolts damage from corrosion only

occurred at the proximal end of the bolt, where the cement grout was often very poor.

• Uncovered parts of resin-grouted rebar were very badly corroded within two years

15

LONG TERM PERFORMANCE OF ROCKBOLTS (CONT.)

Swedish Rockbolt Research (Helfrich and Finkel, 1989)• Approximately 50% of cement grouted bolts had reduced or insufficient

grouting.• Severe pitting corrosion was observed in cement grouted rockbolts.• General surface corrosion was observed from uncoated bolts.• Resin-grouted bolts indicated increasing rust formation with age.• Cement-grouted bolts had no or poor grout quality at the distal end.• Resin-grouted bolts showed no or poor grout quality at the proximal

end.

16

Ground Anchor Performance

Case Studies 35 case studies reported by FIP

(1986) Rock bolt experience in mining

industry NCHRP 24-13 survey

– Several reported incidents in transportation sector

History of Performance In general performance

has been satisfactory Some corrosion

problems- near anchor head, MIC, stray currents Creep Loads not anticipated in

design- ice loads, poor drainage, cyclic loads

17

5. NDT

18

UTILITY OF NDT

Electrochemical Tests–Half cell–Polarization

Indicate integrity of corrosion protection systems.

Wave Propagation Techniques– Impact Test–Ultrasonic Test

Assess the current condition of an element, i.e., severity of corrosion.

19

APPROACH1. A number of monitoring techniques are included in the test protocols for

NDE of rock bolts2. The SE, IR , UT, and ECT techniques are applied to evaluate the condition

of grouted rock bolts3. Installation details can be distinguished with NDE, and these details are

useful for condition assessment and service life modeling4. Reliability and durability are affected by lock-off loads, and whether the

design load is determined by geotechnical or structural considerations

20

SIGNAL ATTENUATION

SIGNAL ATTENUATION

40 Kips

10 Kips

LIFT-OFF TEST RESULTS

BOLT #

LIFT-OFF(Kips)

NDT RESULT

CORRECTNDT

3 36 GOOD Y4 38 GOOD Y7 17 GOOD (?) N (?)8 22 GOOD N9 20 NG Y

G1 7 NG Y6 LOOSE NG Y17 LOOSE G/NG Y (?) 22

VERIFICATION OF NDT

23

Total Length = 15 Feet

00.0020.0040.0060.0080.01

0.012

0 1000 2000 3000 4000

Frequency (hz)

Mob

ility

MOBILITY CURVES

Normal Distressed

P

Q

fR

fp

24

Bruceton SRCM

SE Test Results

UT Results

25

HALF-CELL POTENTIALS

26

CORROSION RATES OBSERVED WITH LPR

27

LOCH ALVA DAM

28

DAM TIE DOWNS - BUTTON HEAD ANCHORAGES

29

-0.4

-0.2

0

0.2

0.4

0.6

outp

ut (v

olts

)

0.000

0

0.000

5

0.001

0

0.001

5

0.002

0

0.002

5

0.003

0

0.003

5

0.004

0

0.004

5

0.005

0

0.005

5

0.006

0

0.006

5

0.007

0

0.007

5

0.008

0

0.008

5

0.009

0

0.009

5

0.010

0

Anchor #1

Anchor #6

time (s)

Loch Alva Anchor #1

Anchor #2

Anchor #3

Anchor #4

Anchor #5

Anchor #6

LOCH ALVA DAM - IMPACT TEST RESULTS

30

Grout Condition Assessment for Rock Bolts & Ground Anchors

31

6. SERVICE LIFE MODELING

32

CORROSIVENESS OF SOILS

Corrosiveness Resistivity(ohm/cm) pH

Normal 2000 − 5000 5 − 10Aggressive 700 − 2000 5 − 10

Very Aggressive < 700 < 5

33

Recommended Parameters for Service-Life Prediction Model

(Withiam et al., 2002)

Parameter Normal Aggressive VeryAggressive

K (µm) 35 50 340r 1.0 1.0 1.0

34

0

200

400

600

800

1000

1200

1400

1600

1800

2000

0 5 10 15 20 25 30 35

Age (Years)

Thic

knes

s Lo

ss ( µ

m)

Rock Bolts, Anchors & TiebacksBar Mats

EliasX = 80*t0.8 Caltrans

X = 80*t

RomanoffX = 150*t0.8

Ellenville

Effect of Time on Metal Loss for Rock Bolts & Ground Anchors

35

( )yrtside

mAside

mX 8.0×

=

µµ

Statistics for A µ = 60 µm/yrσ= 40 µm/yrPDF - lognormal

SERVICE-LIFE MODEL

36

7. CONCLUSIONS

• The type of rock reinforcement and installation details have a significant effect on condition assessment and durability.

• Older installations may not incorporate the same level of details and corrosion protection afforded to more modern applications.

• Existing data on performance and service life are useful to identify vulnerabilities of different systems.

• In general, systems are most vulnerable to deterioration near the anchor heads.

• NDT are useful tools for condition assessment.• Generalized service-life models are available from the literature• More data are needed from condition assessment to incorporate

affects of climate and site conditions on performance

37