COMPARISON OF EUS-GUIDED TRUCUT WITH EUS-GUIDED FINE-NEEDLE ASPIRATION

IN SUBEPITHELIAL TUMORS: PRELIMINARY RESULTS OF A

PROSPECTIVE STUDY.

BACKGROUND

� Pathological diagnosis of subepithelial tumors is oftennot possible based on cytology alone.

� Diagnosis of subepithelial tumors must be based onimmunohistochemical analysis, that requieres a larger sample than cytological evaluation alone.

� It has been suggested that a trucut needle would improvethe diagnostic yield of EUS-guided puncture in this settingby providing a core tissue specimen.

To prospectively compare the diagnostic accuracy of EUS-guided trucut needly

biopsy (EUS-TNB) with EUS-guided fine-needle aspiration (EUS-FNA) in the diagnosis of subepithelial tumors.

AIM

PATIENTS

Inclusion criteria

• Diameter of the tumor > 2 cm• Solid lesion• Location in stomach• Prothrombin time >50% and platelet count >50,000

Study population

Consecutive patients diagnosed of a subepithelialtumor sent for EUS evaluation

METHODS

• Patient under conscious sedation.

• EUS-TNB and EUS-FNA of the same lesion (order randomly assigned).

• Needles: 19-gauge trucut biopsy needle and 22-gauge needle.

• On-site cytopathologist:

evaluation of EUS-FNA smear

touch-prep

• As many passes as necessary until a complete cylinder was identified (EUS-TNB) or until the cytopathologistinformed that an adequate specimen was obtained (EUS-FNA)

• Maximum of three passes in both cases

• Diagnosis: based on cytology or histology and immunohistochemical determinations when appropriated

METHODS

22-g needle for EUS-FNA

Tip of the 19-g trucut needle

2 cm tissue tray

cutting sheath

19-g trucut

for EUS-TNBSpring-loaded mechanism

screw-stop lock

adjustment wheel

Firingposition

Endoscopic appearance of a gastric subepithelial tumor

Ultrasonographic appearance of a gastric subepithelial tumor

Trucut tip

EUS-TCB of a gastric subepithelial tumor

FNA TNB

Cytological smear: cluster of spindlecells in a fibrillar matrix. No nuclearatypia (Papanicolau stain,x200)

Core tissue specimen: core ofspindle cell proliferation(H&Ex40)

EUS-FNA cytology vs EUS-TNB histologic cylinder

Immunohistochemical stain for c-kit in cell-block from EUS-FNA

body

body

body

body

body

body

fundus

antrum

body

body

location

3Not possibleInsuficient sample

2GISTMesenchymal t.60x3010

Mesenchymal t.

Mesenchymal t.

Failure

Mesenchymal t.

Failure

Squamous Ca.

Failure

Mesenchymal t.

Mesenchymal t.

histology

EUS-TNB

50x34

230x110

25x21

56x55

46x36

47x45

32x23

26x23

40x38

Size (mm)

1GISTMesenchymal t.1GIST9

2Not possibleMesenchymal t.1GIST8

1GISTMesenchymal t.2-7

2GISTMesenchymal t.1GIST6

3GISTMesenchymal t.--5

1Not doneSquamous Ca.1Not done4

1C-kit negativeIndiferentiate Ca.--3

2Not possibleMesenchymal t.1GIST2

1Not possibleMesenchymal t.3GIST1

passesimmunocytologypassesimmuno

EUS-FNA

RESULTS

58+61 x 37+27 1.5 + 0.7 1.7 + 0.8

RESULTS

5/9 (55%)6/6 (100%)C-KIT DETERMINATION

9/10 (90%)7/10 (70%)DIAGNOSIS

EUS-FNAEUS-TNB

P=NS

P=NS

1. The diagnostic accuracy of EUS-TNB and EUS-FNA in subepithelial tumors is good and similar.

2. Determination of c-kit seems to be more feasible in the tissue specimen provided by EUS-TNB.

3. More patients have to be studied before taking definitive conclusions about final accuracy of the two techniques.

CONCLUSION