Clearwater Systems

1

The Hytronic System Dolphin

Clearwater Systems, LLCAdvanced Water Treatment Equipment

Clearwater Systems

2

Company Profile Technology developed at a University

Chief subcontractor is ISO 9002 approved

Excellent track record • 500 installations• Over 5 years of service

New patented technology unique in the marketplace

Clearwater Systems

3

Electronic Water Treatment

ELIMINATES USE OF ALL WATER TREATMENT CHEMICALS, AND THEREFORE THEIR RELEASE TO

THE ENVIRONMENT VIA BLOWDOWN AND DRIFT

&

PREVENTS SCALE FROM FORMING

&

CONTROLS MICROBIAL GROWTH

Degrades and removes old scale, encrustation and bio-film Creates conditions that stop localized and uniform corrosion Allows potentially significant water savings

Clearwater Systems

4Hardware

transformer panel and spool piece

no obstructions in pipe

9 sizes from 3/4” to 12”

Clearwater Systems

5

Microbial Control

Corrosion Control

Scaling Control

Cooling System Treatment

Clearwater Systems

6

Typical Cooling Tower

Evaporation = 1% circulation rate

Blowdown = Evaporation/(CC-1)

DT = 10 oF

Clearwater Systems

7

Scale Prevention

Scale Formation

on

Surface

Particle Formation

in

Bulk Solution

Calcium Carbonate

(CaCO3) Scale

Calcium Carbonate

(CaCO3) Particles

Clearwater Systems

8Corrosion Performance in Cooling Towers

• No Localized Attack

• No pitting or microbial induced corrosion (MIC)

• Uniform Corrosion• Benign alkaline chemistry with high hardness (pH 7.5

to 9.0)

• No attack on copper/galvanized

• 2 - 5 mpy on steel

Clearwater Systems

9

Microbe Control Microbes controlled by incorporation Pulsed-Power FDA approved for Pasteurization

Microbes

Encapsulated Microbes

Clearwater Systems

10

Bio-Film Control

Bio-Film in Cooling Towers

7/13 7/15 7/17 7/19 7/21 7/23

Bio

-Film

Gro

wth

Dolphin Control Chemical Control

Clearwater Systems

11

Biological Control - 1000 ton @ 5 cycles

TBC at PA Hospital (CFU/ml)

05,000

10,00015,00020,000

06/0

1/99

07/0

1/99

08/0

1/99

09/0

1/99

10/0

1/99

11/0

1/99

12/0

1/99

Clearwater Systems

12

Biological Control - 175 ton @ 8 cycles

Figure 2 - TBC at 175-ton CT Tower (CFU/ml)

05,000

10,00015,000

20,000

07/0

1/99

08/0

1/99

09/0

1/99

10/0

1/99

11/0

1/99

12/0

1/99

Clearwater Systems

13

Biological Control - 600 ton @ 5.5 cycles

Figure 1 - TBC at 600-ton PA Tower (CFU/ml)

05,000

10,00015,000

20,000

6/30/1998

8/30/1998

10/30/1998

12/30/1998

2/28/1999

4/30/1999

6/30/1999

8/30/1999

10/30/1999

12/30/1999

Clearwater Systems

14

Biological Control

Only blowdown needs to be controlled

Requires constant monitoring and adjustment

Little or no bio-film presentLimited effectiveness on bio-film

Not species specificBiocides are often species specific

No corrosives usedBiocides are often corrosive

Typical TBC of 1,000 to 2,000 CFU/ml

Typical TBC of 20,000 to 50,000 CFU/ml

Dolphin SystemChemical Treatment

Clearwater Systems

15

Boiler Installation

Clearwater Systems

16

Boiler Application

Carbonates precipitate as a powderEliminates need for water softener and phosphates

Precipitation lowers alkalinity of boilerEliminates formation of CO2 and need for amines

Old scale will flake off over timeImproves heat transfer efficiencies

Clearwater Systems

17Corrosion Performance in Boilers

No Localized Attack • No pitting

• Less CO2 generation avoids acid corrosion in boiler condensate return lines (pH of 7.0 to 8.4)

Uniform Attack • Boiler operates at a pH of 10.5 where iron and steel develop

a passive magnetite surface resulting in negligible uniform corrosion

Clearwater Systems

18

Scale Removal Scale removal by crack propagation

Clearwater Systems

19

Pollution Prevention

• Biocides can cause problems in sewer treatment plants

• Some anti-corrosion additives contain heavy metals (Zn and Mo)

• Many chemicals in concentrated form fall under OSHA regulations

• Phosphates and brine are a concern in discharges

• Drift carrying chemicals can cause employee relations issues

Clearwater Systems

20

Cost Savings

Savings on the cost of chemicals & softener

Savings on fuel

Savings on maintenance (tower, heat exchanger, boiler)

Savings on water purchase and disposal

Savings on regulatory compliance

Clearwater Systems

21

Conclusions

• The Dolphin is an alternative to chemical treatment on cooling towers and boilers.

• The Dolphin is in commercial use under a variety of water conditions.

• The Dolphin is a rugged system that is tolerant of some neglect.

Clearwater Systems

22Appendix Zeta Potential

•Tiny, non-symmetric crystals (proto-crystals) with strong surface

charges develop high zeta potentials (diffuse counter-ion charge).

•Proto-crystals repel due to this high zeta potential

•Vibrating the particles at their resonant frequency with an electro-magnetic field, homogenizes the diffuse counter-ion charges, lowers the zeta potential and allows agglomeration .

Clearwater Systems

23Appendix Distinction from Magnets

•Range of field strengths cover all water variations

•Coils “ring” yielding harmonics into the kilohertz to megahertz range

Clearwater Systems

24AppendixInactivation of Microbes

Water sample from Dolphin treated tower with 106/ml microbes added

10

100

1,000

10,000

100,000

1,000,000

10,000,000

0 2 4 6 8 10 12 14 16

Hours

CF

U/m

l

1 day storage 21 day storage

Clearwater Systems

25

Boiler ChemistryCa++ + CO3

= + H2O <-> Ca++ + 2OH- + CO2 Dominates at low pH

Ca++ + CO3= + H2O <-> CaCO3 + H2O Dominates at high pH

(typical equilibrium at 10.0 to 10.5 pH)

Cooling Tower ChemistryCa++ + 2HCO3

- <-> Ca++ + 2OH- + 2CO2 Dominates at low pH

Ca++ + 2HCO3- <-> CaCO3 + H2O + CO2 Dominates at high pH

(typical equilibrium at 8.2 to 9.0 pH)

AppendixpH Control Reactions

Clearwater Systems

26 Appendix Boiler Chemistry - Water Softening

Incoming Water with

Ca/Mg HCO3

Regenerate with

NaCl

Flush to drain with CaCl & NaClWastes water and sewer issues with high salts

Softened Water Containing:

NaHCO3 - Causes carbonic acid in condensate

Residual NaCl - Causes enhanced pitting

Residual Ca & Mg - Causes scale formation

Softener

Clearwater Systems

27Appendix Sidestream for Large Pipes

Designed to take 30% of the flow per pass withminimal pressure drop (3 psi)

Clearwater Systems

28Appendix Water Savings

With a Dolphin the cycles of concentration can be increased to 8 or more. (Typically chemically controlled towers are run at 2 to 4 cycles.)

On a 1000 ton cooling tower, going from 3 cycles to 8 can save up to 10,000 gals/day.

Typical cost of water and disposal in most areas is $3.50 per 1000 gals ($35 per day).