alp/4500 manual - diagraphdiagraph - an itw company alp/4500 fasa manual installation page 5...

14
ALP/4500 ALP/4500 FRONT APPLY SWING ARM FRONT APPLY SWING ARM Revision A 6145-017

Upload: others

Post on 29-Dec-2019

11 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: ALP/4500 Manual - DiagraphDiagraph - an ITW Company ALP/4500 FASA Manual Installation Page 5 Installation 2.0 Installation Step 1 - Assemble the Standard Unit [1] Follow the instructions

ALP/4500ALP/4500FRONT APPLY SWING ARMFRONT APPLY SWING ARM

Revision A6145-017

Page 2: ALP/4500 Manual - DiagraphDiagraph - an ITW Company ALP/4500 FASA Manual Installation Page 5 Installation 2.0 Installation Step 1 - Assemble the Standard Unit [1] Follow the instructions

Diagraph - an ITW Company ALP/4500 FASA Manual

Diagraph, an ITW company, continually improves its products, and reserves the right to change or discon-tinue specifications and designs shown in this manual without notice and without incurring obligation. Diagraph has made every effort to verify the informa-tion contained in this manual, but reserves the right to correct any error at the time of the manual’s next revision.© 2004 Illinois Tool Works Inc. All rights reserved.Printed in the United States of America

Page 2

Page 3: ALP/4500 Manual - DiagraphDiagraph - an ITW Company ALP/4500 FASA Manual Installation Page 5 Installation 2.0 Installation Step 1 - Assemble the Standard Unit [1] Follow the instructions

Diagraph - an ITW Company ALP/4500 FASA ManualIntroduction

1.0 Introduction

1.1 The ALP/4500 Front Apply Swing Arm Applicator

The Front Apply Swing Arm, referred to hereafter as the FASA, is an applicator module which allows either single or dual panel label placement. This module utilizes a linear pneumatic extension cylinder which rotates an arm containing a pivoting tamp pad to the product.

1.2 Product Safety

Safety awareness is critical when working with equipment that contains moving parts and extending pneumatic cylinders. Please read all warnings and cautions thoroughly before operating this device.

WARNINGS

• WARNING - Moving parts of this machine can present hazards. Components that cannot be guarded because of loss of functionality are marked with a warning symbol.

• Be aware of the tamp cylinder extension distance, and avoid accidental trig-gering of the photosensor.

• When servicing the unit’s electronic assemblies, always remove the power cord from the unit to prevent accidental shock.

• When running for extended periods of time, use caution when accessing the drive module circuitry. The motor drive power transistors, motor case, and motor heatsink can become hot under constant use.

• Always close the air inlet valve shutoff when removing or servicing pneu-matic module or tamp cylinder.

• Wear personal protective equipment, as instructed by your supervisor, when operating or working near this device.

COMPLIANCE

• CAUTION: Not for use in a computer room as defined in the Standard for the Protection of Electronic Computer/ Data Processing Equipment, ANSI/NFPA 75.

• ATTENTION: Ne peut être utilissé dans une salle d’ordinateurs telle que définie dans las norme. ANSI/NFPA 75 Standard for the Protection of Elec-tronic Computer/ Data Processing Equipment

• This unit has been tested and found to comply with the limits for a Class A device, pursuant to part 15 of the FCC Rules.

• This unit has been tested to comply with CE Standards.

Introduction Page 3

Page 4: ALP/4500 Manual - DiagraphDiagraph - an ITW Company ALP/4500 FASA Manual Installation Page 5 Installation 2.0 Installation Step 1 - Assemble the Standard Unit [1] Follow the instructions

Diagraph - an ITW Company ALP/4500 FASA ManualIntroduction

• This unit is equipped with an Emergency Stop switch. Depressing this switchwill cause all machine operations to cease.

• This unit was tested and it was determined that a potential for tipping exists in certain orientations. In compliance with UL safety standards, the stand must be secured to the surface where it is located. Additionally, this type of securing will result in greater product application accuracy.

1.3 Document Conventions

Formatting conventions are used throughout this manual as a method of providing consistency for notes and warnings.

.

.

1.4 Warranty Information

The ALP/4500 FASA system, including all components unless otherwise specified, carries a limited warranty.

For all warranty terms and conditions, contact Diagraph, an ITW Company, for a complete copy of the Limited Warranty Statement.

NoteThis symbol appears throughout the manual to provide additional information on a topic, including technical details, exceptions to the instructions and other pertinent information. Notes are identified with a note pad and pen symbol and italics text.

WARNING This symbol indicates a danger of injury to the user. Hazards are identified by the exclamation mark in a triangle and bold italics text.

Introduction Page 4

Page 5: ALP/4500 Manual - DiagraphDiagraph - an ITW Company ALP/4500 FASA Manual Installation Page 5 Installation 2.0 Installation Step 1 - Assemble the Standard Unit [1] Follow the instructions

Diagraph - an ITW Company ALP/4500 FASA ManualInstallation

2.0 Installation

Step 1 - Assemble the Standard Unit[1] Follow the instructions in the ALP/4500

manual for assembling the standard unit.[2] If this is a conversion from a tamp applicator,

remove tamp cylinder assembly and dovetail track before proceeding. Detach the cylinder home sensor from the cylinder, but leave the cable connected.

Step 2 - Attach the FASA Dovetail Track[1] Install the longer dovetail track with the

provided 10-32 low-profile socket head cap screws.

[2] Use the provided Loctite to the screw threads before tightening.

Installation Page 5

Page 6: ALP/4500 Manual - DiagraphDiagraph - an ITW Company ALP/4500 FASA Manual Installation Page 5 Installation 2.0 Installation Step 1 - Assemble the Standard Unit [1] Follow the instructions

Diagraph - an ITW Company ALP/4500 FASA ManualInstallation

Step 3 - Attach the FASA Module

[1] Slide the FASA module onto the dovetail track.

[2] Connect the yellow vacuum line to the pneumatic vacuum generator.

[3] Connect the blue extension pressure line from the top of the cylinder to the pneumatic block as shown in the image below.

[4] Connect the red retract pressure line from the bottom of the cylinder to the pneumatic block as shown in the image below.

Cylinder Bottom

To Bottom of Tamp Cylinder

To Top of Tamp Cylinder

To Vacuum Pad

Installation Page 6

Page 7: ALP/4500 Manual - DiagraphDiagraph - an ITW Company ALP/4500 FASA Manual Installation Page 5 Installation 2.0 Installation Step 1 - Assemble the Standard Unit [1] Follow the instructions

Diagraph - an ITW Company ALP/4500 FASA ManualInstallation

Step 4 - Electrical Connections[1] If not already connected, insert the Cylinder

Home sensor cable through the fitting in the side of the rear enclosure.

[2] Connect the Cylinder Home sensor cable to the to terminal block labeled J15. The circuit board shows the correct wire color placement positions.

Installation Page 7

Page 8: ALP/4500 Manual - DiagraphDiagraph - an ITW Company ALP/4500 FASA Manual Installation Page 5 Installation 2.0 Installation Step 1 - Assemble the Standard Unit [1] Follow the instructions

Diagraph - an ITW Company ALP/4500 FASA ManualS

etup

3.0 Setup

Step 1 - Tamp Pad Alignment [1] Position the tamp pad as shown by adjusting

the two bumper screws. This is set at the factory, and should not need adjustment. The tamp pad should be angled to approximately 20 degrees with respect to the bracket mount. This ensures smooth label transfer to the pad.

[2] The shock absorber is also set at factory and should not require adjustment. If adjustment is necessary, make sure that the bumper is not allowed to bottom out on the shock cylinder body. The shock retraction rate can be adjusted by rotating the top of the shock cylinder cap. Again, this should not require adjustment.

Step 2 - Arm Alignment [1] With the tamp pad properly angled, slide the

FASA module into position by adjusting the height offset. This is accomplished by loosening the screws shown at the left.

[2] Making sure that the FASA arm will not pinch any hoses or components, turn on the air pressure for setting the final adjustments.

[3] Align the pad to the peel blade so that the pad is 1/16th of an inch below the peel blade. This allows the labels to “snap” free of the liner. Once this position is set, tighten the offset screws.

[4] With the height offset determined, set the FASA position in the dovetail so that the tamp pad is roughly 1/16th to 1/8th of an inch away from the peel blade.

This sets in/outposition only

Height Adjustment Screws

Setup Page 8

Page 9: ALP/4500 Manual - DiagraphDiagraph - an ITW Company ALP/4500 FASA Manual Installation Page 5 Installation 2.0 Installation Step 1 - Assemble the Standard Unit [1] Follow the instructions

Diagraph - an ITW Company ALP/4500 FASA ManualS

etup

Step 3 - Pneumatic Calibration[1] The vacuum pressure is factory set to 30 psi,

and should not be changed. Vacuum pressures below 30 psi are not recommended.

[2] The tamp pressure determines the rate at which the cylinder cycles. Pressures higher than 60 psi or lower than 25 psi are not recommended. Standard setting is at 45 psi.

[3] The air assist is factory set for 20 psi. This should be adequate for most applications. If the label length is longer than 6 inches, the air assist pressure may need to be increased, but should be kept below 40 psi.

VAC AIR TAMP

30 20 45

Step 4 - FASA Arm Application Rate[1] The air flow controls adjust the individual rate

of extension and retraction of the FASA arm. [2] The control for extension speed is located at

the lower portion of the cylinder. This has been set at the factory for best possible speed. If adjustment is required, make adjustments slowly.

[3] The control for retraction speed is located at the upper portion of the cylinder. This has also been set at the factory for best possible return speed. If adjustment is required, keep in mind that the cylinder home position may also require re-positioning. If the return rate is too high, the pad may bounce on return, and cause label jams.

Retraction Speed Control

Extension Speed Control

Setup Page 9

Page 10: ALP/4500 Manual - DiagraphDiagraph - an ITW Company ALP/4500 FASA Manual Installation Page 5 Installation 2.0 Installation Step 1 - Assemble the Standard Unit [1] Follow the instructions

Diagraph - an ITW Company ALP/4500 FASA ManualS

etup

Step 5 - Parameter Settings - MTool

[1] The ALP/4500 unit must have the correct application mode set for the given application. This is performed with the MTool software program (version v2.5 or later).

[2] There are a few possible modes that are applicable for the FASA applicator.

• Tamp mode will apply one label per photosensor trip.

• Tamp/Tamp mode will apply two labels per photo-sensor trip, and be separated by the Second Product Delay time. This time can be set in MTool, or on the unit. The unit must be configured for Tamp/Tamp to display this screen in the setup menus.

[3] Select the correct mode and send the values. Exit the program when complete.

.

Note If the Tamp/Tamp mode is selected, it is still possible to apply only one time per photosensor trigger by setting the Second Product Delay to zero at the ALP/4500 unit.

Setup Page 10

Page 11: ALP/4500 Manual - DiagraphDiagraph - an ITW Company ALP/4500 FASA Manual Installation Page 5 Installation 2.0 Installation Step 1 - Assemble the Standard Unit [1] Follow the instructions

Diagraph - an ITW Company ALP/4500 FASA ManualS

etup

Step 6 - Parameter Settings - ALP/4500

[1] After selecting the correct Application Mode in MTool, set the delay(s) required to optimally position the label on the product. Use the Product Delay, as described in the ALP/4500 manual to set the first application position.

[2] If the unit is in the Tamp/Tamp mode, a new screen will be accessible in the Setup screens. Second Delay determines when the FASA will apply for the second time (from one product trigger). This time begins once the first delay expires. It is important that there is enough time entered to allow the label to be printed. If the second delay expires before the second label in on the pad and ready, it will not be applied. Typical minimum delays of 1500 mS (6 inch long label at maximum print speed) are required to complete the second application.

[3] If the unit is in the Tamp/Tamp mode, but the application occasionally requires only one label per trigger, set the Second Delay to zero (0) to cancel the second application.

.

Note If the Tamp/Tamp mode is selected, it is still possible to apply only one time per photosensor trigger by setting the Second Product Delay to zero at the ALP/4500 unit.

Setup Page 11

Page 12: ALP/4500 Manual - DiagraphDiagraph - an ITW Company ALP/4500 FASA Manual Installation Page 5 Installation 2.0 Installation Step 1 - Assemble the Standard Unit [1] Follow the instructions

Diagraph - an ITW Company ALP/4500 FASA ManualR

eplacement P

arts

4.0 Replacement Parts

4.1 ALP/4500 FASA Replacement Part List

Part Number Description

6145-017 ALP/4500 FASA Manual

6145-740 Cylinder Home Sensor

6170-009(9405k12 McMaster Carr)

Bumper, Posts

1903-345 Shock Absorber

(9271k59 McMaster Carr) Music Wire Torsion Springs

(6391k135 McMaster Carr) Bronze Bearing

6170-007(92196A533 McMaster Carr)

Knuckle Shoulder Bolt

6170-004 Swing Arm

Pneumatic Cylinder

6170-010 Knuckle Base

6170-014 Plate, Knuckle Pad

6170-030 Female Dovetail Bracket

6170-031 Male Dovetail Bracket

6170-033 Support Braket

6170-034 Cylinder Support Block

6170-035 FASA Shaft

6170-036 Rod Cylinder Pin

6145-002 Single Rod Cylinder Bracket

6170-037 Bracket, Shock Absorber Support

6170-038 6 inch Shaft

6170-039 L-Bracket, FASA

6170-040 Shaft, 3/8inch Threaded

6170-041 Support Block, FASA

6170-042 Knuckle Base, FASA

6170-043 Knuckle Pad Plate, FASA

6170-044 Tamp Cylinder Assembly, ALP/4500 FASA

5312-003(6391K135 McMaster Carr)

3/8 inch Bronze Bearing, 1” LG.

Replacement Parts Page 12

Page 13: ALP/4500 Manual - DiagraphDiagraph - an ITW Company ALP/4500 FASA Manual Installation Page 5 Installation 2.0 Installation Step 1 - Assemble the Standard Unit [1] Follow the instructions

Diagraph - an ITW Company ALP/4500 FASA ManualR

eplacement P

arts

4.2 Exploded Assembly

Replacement Parts Page 13

Page 14: ALP/4500 Manual - DiagraphDiagraph - an ITW Company ALP/4500 FASA Manual Installation Page 5 Installation 2.0 Installation Step 1 - Assemble the Standard Unit [1] Follow the instructions

Diagraph - an ITW Company ALP/4500 FASA ManualTroubleshooting

5.0 Troubleshooting

This troubleshooting section specifically covers faults with the FASA module. Please refer to the ALP/4500 Manual for troubleshooting the main system.

Problem Cause Correction

Label is feeding into the tamp pad edge

Improper pad height adjustment

Tamp pad should return to a position that is approximately 1/16th of an inch below the peel blade

Arm return is too slow Increase Tamp pressure between 30 and 60 psi.Increase upper flow control by turning screw counter-clockwise.

Change in Tamp Pressure Setting

If the Tamp pressure is decreased, the pad may not return as far. Decrease the Shock Absorber resistance to compensate.

Cylinder Home sensor positioned too low

If the Home sensor is triggered too soon, the tamp pad may not have settled in time for the label to be fed. Slide the Home sensor further up the cylinder (while cylinder retracted) while maintaining home sense. Use the red light on the sensor to determine if the cylinder is sensed.

Shock Absorber stiffness is too high

If the shock is adjusted, it may keep the pad from returning to the two bumper posts. Decrease the shock resistance so that the arm is slowed when entering the home position, but not halted by the shock resistance.

Second label is fed to the pad, but is not applied to the same product

Incorrect Application Mode Use MTool to set mode to Tamp/Tamp

Second Delay is too short Increase the Second Delay time to allow the second label to be printed and applied. Increase the time to 5000 mS and work down to the required time for second application.

Troubleshooting Page 14